Home
Dataman 848Pro Manual - Dataman Programmers Ltd.
Contents
1. Site Status Search for Programmers Serialization H2 Cont B4 t5 Disconnect Sites HF Automatic YESI 6 Select Enabled Sites Total Device Samsung F9G8G08U0M 50 48 Project k998g08u0m eprj Checksum w Run Program Stop Programmer Search for programmers Search programmers Please select multiprogramming system fram list bellow and click on button Search to start search for Programmers Multiprogramming system n x Detaman B48Pro bd P Search Search results Programmer 1 Programmer found of Accept x Cancel Menu command displays the dialog Search programmers which is used to reinitialize software configuration and to re find available programmer sites There is no need to use this menu command in normal operation Situations when the command is useful are 1 when first starting DATAMAN 848PRO Stand Alone multiprogramming system 2 when error message Programmer Sites not found is displayed In the dialog Search Programmers use button Search to search for attached programmers The result of search will be displayed in table Search results in Search dialog When programmer sites are successfully found the result shows the programmer type and allows you to accept new settings by button Accept Otherwise No Programmers found message
2. sese 8 In system serial programming by 848 8 Selftest and calibration check eese nennen enne ennt 9 Technical specification 11 Programming GOVICE ccccssceerseseeacccsisnenscssnesessienstesscssnsuacsasenccasaisecatscccsncassasuenebsroeatacreacess 16 16 Production mode 20 SOMWANEC m E 23 Detailed description of Graphics user interface with touch screen 28 Administration of build in PC 99 Troubleshooting and warranty 44 Troubleshooting 44 If you have an unsupported target device 45 Watranty Terifis aid rato DEG Oo Ea item dns 46 We continuously update our manual You may find the latest version from our website www dataman com Conventions used in the manual References to the control program functions are in bold e g Load File Device etc References to control keys are written in brackets lt gt e g lt F1 gt Terminology used in the manual Device any kind of programmable integrated circuits or programmable devices ZIF socket Zero Insertion Force socket used for insertion of target device Buffer part of memory or disk used for temporary data storage USB port type of PC port HEX data format format of data file which may be read w
3. Load project from another location X Cancel Two options are available 1 Load project from Projects folder 2 Load project from another location 25 Load project from Projects folder Load project Select project tile Look in e Data Directory E Projects E files L3 kSfta Bu m with ecc epri LJ kSFlg Bullm epri O 281640 3 g0BuUm with ecc epri k3g8g08u0m epr k3g8g08u0m_with_id epr me28f640c3bb_em eprj me28f640c3bb_it Directory E Projects Drive Data 71 171 MB of 74 651 MB free Drive Data 71 443 MB of 74 651 MB free Hr Info af Load X Cancel Change dir f Load X Cancel When option 1 is selected dialog with list of project files present in Projects folder will appear User can select desired project and load the project by clicking on Load button Dialog can be closed by Cancel button Also basic information about selected project file can be displayed by clicking File info button When option 2 is selected a dialog with list of project files at specified drive and folder will appear User can select desired drive folder and project file and load the project by clicking on Load button Change dir button is used to change current directory to directory selected in Directory list on the left side of dialo
4. s Program Erase Statistics Count down Remains Reload Count down Filename Select desired DATAMAN 848PRO Site and then click on OK button 5 Select device click on icon and 18 select desired device 6 Load data into buffer from file click on pg icon 7 Set Device operation options Device operation options Insertion test Insertion test Enable Device ID check Enable vi Command execution Erase before programming Disable w Blank check before programming Disable v Verify after reading le Verify Verify options 4 20 5 507 Programming parameters User program memory and ID locations C Data EEPROM memory C Configuration bits XJ Cem Set desired operations for the device and then click on OK button 8 Tocustomize device use menu lt Alt S gt 101404 105408 Oscillator 111 RC w OSC2 as Watchdog Timer 1 Enable Power up Timer Brown out Reset OSCSEN 1 Disable v Stack Overflow Reset 1 Enable r 2 1 CCP2 multiplexed with Watchdog Postscaler 111 21128 1 BORV LVP 1 Enable Background debugger Disable 1111 CPD CPB WRTD WRTB WRTC EBTR3 EBTRO 1111 EBTRB 1 Set desired settings for the device and then click on OK button 19 Note Menu Device operation opti
5. Recent project name Checksum of data stored in data buffer for currently selected device Run Button can be operation name for example Program Verify Erase Stop Button Menu File Device Programmer Options Help Each menu item represents one menu command For detailed information about menu commands refer to menu commands description chapter Table with information about programmer sites site and serialization status Table contains key information about current status of programmer sites and serialization information for each Site If serialization is not used the Serialization column remains empty Sites that are not connected have displayed in the Status column Connected Sites have their Status displayed Following are typical values e Ready means the programmer site is connected and ready to start any operation e Present special status of connected Site means the site is connected but it is not selected checked in dialog Select Sites User selected device or project operations will not run on unselected Sites User can set Site selection in dialog Select Sites accessible by menu command Programmer Select Enabled Sites No project file is loaded means the Site is successfully connected but no project file is loaded It also means that no device is selected The recommended action is Load project e othertext describes current status of Site s for example Loading data from disk to buffer
6. ispLSI2xxxV ispLSI2xxxVE ispLSl2xxxVL 4 M4LV xx xx MAA3 xx xx M4A5 xx xx LC4xxxB C V ZC e Various PLD also by JAM player JTAG support e Altera MAX 3000A MAX 7000A MAX 7000B MAX 70005 MAX 9000 MAX II e Xilinx XC9500 XC9500XL XC9500XV CoolRunner XPLA3 CoolRunner ll Notes For all supported devices see actual Device list at www dataman com Package support e support all devices in DIP with default socket e package support includes DIP SDIP PLCC JLCC SOIC SOP PSOP SSOP TSOP TSOPII TSSOP QFP PQFP TQFP VQFP QFN MLF SON BGA EBGA FBGA VFBGA UBGA FTBGA LAP CSP SCSP etc support devices in non DIP packages up to 48 pins with universal adapters Programming speed Device Size bits Operation Time M50FW080 parallel Flash 100000Hx8 8 Mega programming and verify 22 sec MX28F640C3BT parallel Flash 400000Hx16 64 Mega programming and verify 57 sec K9F1GO08UO0M parallel NAND Flash 8400000Hx8 1 Giga programming and verify 229 sec AT45D081 serial Flash 108000Hx8 16 Mega programming and verify 36 sec AT89C51RD2 microcontroller 10000Hx8 programming and verify 15 sec PIC18F452 microcontroller 4000Hx16 programming and verify 4 sec Conditions PG4UW version 2 39a Notes e It is important to know we always use random number patterns for programming speed tests Some of our competitors use a sparse pattern where only so
7. 1 Enable Count down OK Command displays dialog Statistics Statistics gives the information about actual count of device operations which were proceeded on selected type device If one device is corresponding to one device operation e g programming the number of device operations will be equal to the number of programmed devices Statistics dialog contains following options Check boxes Program Verify Blank and Erase which define operations after which statistics values increment Any selected and performed device operation will increment the Total counter and one of the Success or Failure counters depending on device operation result success or failure A combination of partial operations is counted as one operation only For example a Read operation including Verify after Read is one operation A Program operation including Erase and or Verify operations is counted as one operation The next function of statistics is Count down Count down allows checking of the number of device operations and then the number of devices on which device 35 operations have to be done After each successful device operation the value of count down counter is decremented Count down has user defined start number for devices to do When count down value reach zero it means the specified number of devices is complete and a user message about complete count down will be displayed Check bo
8. 2007 10 22 09 23 08 Job Elapsed Time 2 Hours 126 Minutes 6 Seconds Device Name Samsung K9G8G08L0M TSOP43 Device Size 100CE813Ch When this menu command is selected a Job Report will be created and displayed in the Job Report window Before displaying the Job Report the information message is displayed The information message also contains information about the file name to which the Job Report will be saved 27 File Switch to Engineering mode File Device Programmer Options Help Load project Serialization Manage projects Make Job Report Switch bo Engineering mode alistics Shut down computer d TotalO eon Disabled Device Samsung 96860800 TEOP48 Project kSg8g08ulm epri Checksum wv Pun Verify X 50 Command is used to start Pg4uw control program in Engineering mode In this mode user can use Pg4uw software to select any device from the list of supported devices set options for the device load data files for device test the device operations on any programmer site and create a project file which can be used in production mode More information about Engineering mode is available in chapter Engineering mode To switch back to production mode just close Pg4uw control program and run program Pg4uwMC by double clicking on Pg4uwMC icon on the Desktop Note Engineering mode requires connection of external VGA monit
9. Programming device 85 Programming device OK Please insert a new device into socket 24 Next serial value When serialization is active the panel displays current serialization mode and serialization number or label that will be used for next device programmed Recent serial numbers used for each device are displayed in table Site and serialization status in column Serialization Statistics Panel contains information about the number of device operations processed and actual count down status For more details see Statistics dialog menu Options Statistics Recently selected Device name Manufacturer and name of recently selected devices Recent Project name Currently loaded project file name Checksum of data stored in data buffer for currently selected device Button Run can be operation name for example Program Verify Erase Click on button Run will start selected device operation for all connected programmer sites Button can be used when no device operation is running on any programmer site Button Stop Click on button Stop will stop executing of currently running device operation on all connected programmer sites Menu File File Load project This menu command opens dialog project where user can choose from which location the project file has to be loaded and load selected project Load Project Please select one of following actions Load project from Projects folder
10. the control program e Contact DATAMAN directly by completing and submitting the TECHNICAL SUPPORT REQUEST available from our website www dataman com We may need to request data sheets and samples of your target device Any samples will be returned to you after we include your target device in a new version of Pg4uw 45 Warranty terms The manufacturer Dataman Programmers Ltd gives a guarantee on failure free operating of the DATAMAN 848PRO programmer and all its parts materials and workmanship for three years from the date of purchase This warranty is limited to 25 000 cycles on DIL ZIF socket or 10 000 cycles on other ZIF sockets Although we take as much care as possible to integrate high quality components in the built in computer we can t provide a higher warranty as we get from suppliers So there is a limited warranty of one year on all computer parts such as Motherboard CPU HD If the product is diagnosed as defective Dataman Programmers Ltd or the authorized repair centre will repair or replace defective parts at no charge Parts used for replacement and or whole programmer are warranted only for the reminder of the original warranty period For repair within the warranty period the customer must prove the date of purchase These warranty terms are valid for customers who purchase a programmer directly from Dataman The warranty conditions of Dataman sellers may differ depending on the target country law system or
11. Amount of truncated text specifies the percentage of Log file text which will be truncated after Maximum Log file size is reached The higher value means more text will be truncated removed from Log file ELLE 33 Display settings Use invert display mode v OK x Cancel Display settings dialog contains check box Use invert display mode When the checkbox is checked LCD screen will be displayed in inverted mode Otherwise it will be displayed in normal mode Touchpad calibration Command is used for calibration of built in touch pad part of built in LCD touch screen TouchPad calibration This will run touchpad calibration procedure where vou can calibrate touchpad if you encounter not exact reactions from touchpad Calibration procedure will show blank screen with point displayed User has to click on the point with included stylus There will be sequentially displayed few points at different positions Each of the point has ta be clicked by user After clicking required number of points touchpad calibration is complete which will be announced by message displayed Do you wish to start touchpad calibration naw The calibration of touchpad is recommended if encountere unexpected reactions from touchpad If user confirms dialog about touchpad calibration with Yes button calibration procedure will
12. Dataman seller s warranty policy The warranty does not apply to products that are of wear and tear or mechanically damaged Equally the warranty does not apply to products opened and or repaired and or altered by personnel not authorized by Dataman or to products that have been misused abused accidentally damaged or that were improperly installed For unwarrantable repairs you will be billed according to the costs of replacement materials service time and carriage Dataman or its distributors will determine whether the defective product should be repaired or replaced and judge whether or not the warranty applies Please also see Troubleshooting section Manufacturer Dataman Programmers Ltd Station Road Maiden Newton Dorset DT2 OAE United Kingdom 44 0 1300 320719 www dataman com sales dataman com 46
13. count down mode Buffer operations e view edit find replace e fill copy move byte swap word dword split e checksum byte word e print 14 File load save e no download time because programmer is PC controlled automatic file type identification recognition Supported file formats e unformatted raw binary e HEX Intel Intel EXT Motorola S record MOS Exormax Tektronix ASCII SPACE HEX ASCII HEX e Altera POF JEDEC ver 3 0 A e g from ABEL CUPL PALASM TANGO PLD OrCAD PLD PLD Designer ISDATA etc e JAM JEDEC STAPL Format JBC Jam STAPL Byte Code STAPL STAPL File JEDEC standard JESD 71 e VME ispVME file VME2 0 VME3 0 GENERAL e operating voltage AC 100 240V 50 60Hz power consumption max 300W active e dimensions 625x465x115 mm 24 6x18 3x4 5 inch e weight programmer 14 9kg 32 85 Ibs e temperature 5 C 35 C 41 F 95 F humidity 20 80 non condensing Package included Standard accessories DATAMAN 848PRO programmer diagnostic POD for ZIF socket selftest of the programmer 1 diagnostic POD for ISP connector selftest of the programmer 1 e ISP cable 8x anti dust cover for ZIF socket 8x e user manual software registration card calibration test report e transport case Bonus pack e ESD wrist strap with cord and banana plug e Vacuum pen Additional services e Keep Current e AlgOR e free technical support
14. easy Hands free operation asynchronous and concurrent operation allows a chip to begin programming immediately upon insertion of a chip The operator merely removes the finished chip and inserts a new chip Operator training is therefore minimized DATAMAN 848PRO supports all kinds and types of silicon technology found in todays and tomorrows programmable devices without family specific modules You can be sure SSS 4 that new device support requires the software to be updated and if necessary simple package converter programming adapter therefore the ownership costs are minimized Using built in in circuit serial programming ISP connector the programmer is able to program ISP capable chips in circuit DATAMAN 848PRO provides very competitive price coupled with excellent hardware design for reliable programming It has probably best value for money programmer in this class DATAMAN 848PRO provides very fast programming due to high speed FPGA driven hardware and execution of time critical routines inside of the programmer At least programming speed is faster than competitors in this category for many chips it is much faster than most competitors As a result when used in production this programmer waits for an operator and not the other way round DATAMAN 848PRO provides the two banana jacks one for ESD wrist strap connection for easy to implement ESD protection and the second one for connection to ground FPGA based to
15. start Calibration procedure will show blank screen with point displayed User has to click on the point with stylus There will be sequentially displayed few points at different positions Each of the point has to be clicked by user After clicking required number of points touchpad calibration is complete which will be announced by information message displayed 34 Sounds Sound settings 34 9 MS Windows sound No sound v Use beep sound on touchscreen press v ok X Cancel Dialog Sounds settings allows user to select the sound mode of program Program generates sounds after some activities e g activities on device programming verifying reading etc Program generates sound also when warning or error message is displayed User can now select sound from MS Windows system sound requires installed sound card PC speaker or No sound The check box Use beep sound on touch screen press allows to switch beep sound on or off When the checkbox is checked beep sound will be generated on each touch screen press that software detects Otherwise no beep sound will be generated Options Statistics Statistics Current statistics Apply statistics increment on Success 0 v Device Program Failure 0 Device Verify Total 0 Device Blank check v Device Erase Clear statistics aunt dow
16. the programmer software and the target device e Mail fax Print and complete the RETURNS FORM available from our website www dataman com Include everything that you consider being relevant about the programmer software and the target device Send the completed form by mail or fax to DATAMAN fax number in the control program menu Help About or to your local dealer e Phone Call your local dealer or DATAMAN s customer support center 44 0 1300 320719 If your programmer is diagnosed as defective consult your local dealer or DATAMAN about the pertinent repair center in your country Please carefully include the following items in the package e Defective product Completed RETURNS FORM available from our website www dataman com e Photocopy of a dated proof of purchase Without all these items we cannot admit your programmer for repair Note You may find the DEVICE PROBLEM REPORT form e at our Internet site www dataman com section Support Problem report 44 If you have an unsupported target device If you need to operate on a target device not supported by the control program for programmer please do not despair and follow these next steps e Look in the device list of the latest version of the control program on our Internet site section Download file corresponded to your programmer Your new target device may already be included in this version If yes download and install the new version of
17. will be displayed in table Search results and button Accept is disabled 29 If search result is No Programmers found please try to turn off Stand Alone programmer by menu File Shut down computer turn off the power button on the back side of programmer wait for 15 seconds or more and start programmer again If the search result is still No Programmers found please refer to troubleshooting documentation Programmer Connect Sites Menu command starts control applications for all available programmer sites The Connecting Sites indicator is displayed during connecting of sites Additional information about site connection progress is displayed for each site in the Status panel on the main screen Programmer sites are numbered from 1 to 8 in direction of physical placing of sites from left to right When connection process is complete indicator Connecting Sites will be hidden The Status panel will contain information about each site Following status information are most common e Ready means the programmer site is connected and ready to start any operation e Present special status of connected site means the site is connected but it is also not selected checked in dialog Select sites User selected device or project operations will not run on Present unselected sites User can set site selection in dialog Select sites accessible by menu command Programmer Select Enabled sites e No projec
18. window content to problem report file Problem report is useful when an error occurs in the control program or 37 programmer and that the user can not resolve and he must contact programmer manufacturer In this case when customer send message to manufacturer about his problem it is good to send also problem report Problem report can help manufacturer to localize the reason of error and resolve it sooner Help Update software This important menu command allows users to make software updates After selecting this item program will display question Are you sure If user confirms the question with answer Yes dialog Select installation package will be displayed Select installation package Look in e Data w Directory 1 files HobReports Logs Programmer LI Projects m Drive Data 71 170 MB of 74 651 MB free Change dir 4 Select x Cancel In this dialog user can browse for the pg4uwarc installation package he wishes to install The installation package can be copied before to shared Stand Alone folder via network or it can be stored on a USB key which can be plugged into USB port of Stand Alone programmer When USB key is plugged to USB port of programmer new drive letter assigned with USB key will appear in list of available drives in dialog Select installation package User can than select this drive and run instal
19. 00000 kB Amount of truncated text E5 sv v OK x Cancel Log file is text file containing information about Pg4uwMC control program operation flow which means information about loading project files device operation types and device operation results 32 Main Log file name in Stand Alone programmer can not be modified by user it has defined value E Logs reportmc log where drive E is placed on built in disk of Stand Alone programmer Multiprogramming system generates a few Log files One main Log file for program Pg4uwMC and Log files for each of the running Programmer Sites Each site has its own Log file The name of the site s Log file has the same prefix as the name of the Log file specified in the edit box Log file The file name prefix is followed by the number of the site in the form of _ lt Snum gt All Log files are placed into the folder E Logs reportmc log where drive E is placed on built in disk of standalone programmer The Log file names used are reportmc log Pg4uwMC main Log file reportmc_ 1 log Site s 1 Log file reportmc_ 2 log Site s 2 Log file reportmc_ 3 log Site s 3 Log file and so on Following options can be set for Log file creation e option Append Log file sets usage of Log file Log file will be created after the first restart of Pg4uwMC For all following executions of Pg4uwMC the existing Log file will be preserved and new data will be appende
20. COP8xxx series e Microcontrollers NEC uPD78xxx series e Microcontrollers Novatek NT68xxx series e Microcontrollers Scenix Ubicom SXxxx series e Microcontrollers SGS Thomson ST6xx ST7xx ST10xx STR7xx series e Microcontrollers Tl MSP430 and MSC121x series e Microcontrollers ZILOG Z86 Z89xxx and Z8xxx series EE 12 eMicrocontrollers other EM Microelectronic Fujitsu Goal Semiconductor Hitachi Holtek Princeton Macronix Winbond Infineon Siemens NEC Samsung Toshiba Notes For all supported devices see actual Device list at www dataman com Programmer through ISP connector e Serial E E PROM IIC series MW series SPI series KEELOQ series serial data Flash PLD configuration memories e Microcontrollers Atmel AT89Sxxx AT90Sxxxx ATtiny ATmega series e Microcontrollers Cypress CY8C2xxxx e Microcontrollers Elan EM78Pxxx EM6xxx series e Microcontrollers EM Microelectronic 4 and 8 bit series e Microcontrollers Microchip PlCmicro PIC10xxx PIC12xxx PIC16xxx PIC17xxx PIC18xxx PIC24xxx dsPIC series e Microcontrollers Motorola Freescale HC11 series HC908 series both 5 wire All wire HCS08 HCS12 e Microcontrollers NEC uPD7xxx series e Microcontrollers Philips LPC2xxx series LPC series 89xxx series e Microcontrollers Scenix Ubicom SXxxx series Microcontrollers MSP430 both JTAG and BSL series MSC12xxx series e PLD Lattice ispGAL22xV10x ispLSMxxxEA ispLSI2xxxE
21. DATAmAn User s Manual for DATAMAN 848PRO ast universal 8x 48 pindrive Stand Alone concurrent multiprogramming system October 2007 COPYRIGHT 2007 Dataman Programmers Ltd This document is copyrighted by Dataman Programmers Ltd United Kingdom All rights reserved This document or any part of it may not be copied reproduced or translated in any form or in any way without the prior written permission of Dataman Programmers Ltd The control program is copyrighted by Dataman Programmers Ltd The control program or any part of it may not be analyzed disassembled or modified in any form on any medium for any purpose Information provided in this manual is intended to be accurate at the moment of release but we continuously improve all our products Please check for an updated manual on our website at www dataman com Dataman Programmers Ltd assumes no responsibility for misuse of this manual Dataman Programmers Ltd reserves the right to make changes or improvements to the product described in this manual at any time without notice This manual contains names of companies software products etc which may be trademarks of their respective owners Dataman Programmers Ltd respects those trademarks ZLI 0308A Table of contents INtHOGUCHIONN Pr 4 DATAMAN 848PRO elements eese nennen nnne nnne nnne enne enne 7 Manipulation with the programmed device
22. V e current limitation overcurrent shutdown power failure shutdown e ESD protection on each pin of socket IEC1000 4 2 15kV air 8kV contact continuity test each pin is tested before every programming operation ISP connector 20 pin male type with miss insertion lock e 6 TTL pindrivers provides L CLK pull up pull down level selectable from 1 8V up to 5V to handle all low voltage devices e 1x VCCP voltage range 2V 7V 100mA can be applied to two pins 11 programmed chip voltage with both source sink capability and voltage sense 1x VPP voltage range 2V 25V 50mA e target system supply voltage range 2V 6V 250mA e ESD protection on each pin of ISP connector IEC1000 4 2 15kV air 8kV contact two output signals which indicate state of work result LED OK and LED Error active level min 1 8V e input signal switch YES equivalent active level max 0 8V DEVICE SUPPORT valid for each programming module Programmer eEPROM NMOS CMOS 2708 27xxx and 27Cxxx series with 8 16 bit data width full support for LV series e EEPROM NMOS CMOS 28xxx 28Cxxx 27EExxx series with 8 16 bit data width eFlash EPROM 28Fxxx 29Cxxx 29Fxxx 29BVxxx 29LVxxx 29Wxxx 49Fxxx series from 256Kbit to 32Mbit with 8 16 bit data width full support for LV series eSerial E E PROM 24Cxxx 24Fxxx 25Cxxx 45Dxxx 59Cxxx 25Fxxx 25Pxxx 85xxx 93Cxxx NVM3060 MDAxxx series full support
23. agreement starts formatting of disk D and installation of control program recovery deletes Programmer directory on disk E and creates new one Also directories Updates and Temp has been erased and recreated When recovery is completed you should see System recovery completed Then press any key and system will restart First start of the operating system after recovery may be a bit longer with one additional restart 43 Troubleshooting and warranty Troubleshooting We really want you to enjoy our product Nevertheless problems can occur In such cases please follow the instructions below elt might be your mistake in not properly operating the programmer or its control program Pg4uw e Please read carefully all the enclosed documentation again Probably you will find the answer right away e Try to install programmer and Pg4uw on another computer If your system works normally on the other computer you might have a problem with the first PC Compare differences between both computers e Ask your in house guru every office has one e Ask the person who already installed the programmer If the problem persists please call the local dealer from whom you purchased the programmer or call DATAMAN direct Most problems can be solved by email fax or phone e E mail Complete and submit the TECHNICAL SUPPORT REQUEST available from our website www dataman com Include everything that you consider being relevant about
24. ctors on back side of programmer Turn on programmer 2 Run the control program double click on icon 3 Find DATAMAN 848PRO Site programmer lt Ctrl F gt or right click on panel Programmer 17 PG4UW v2 43 10 2007 universal control program for Dataman programmers prj Save em t ye Find programmer Programmer Dataman 448Pro Site Dataman 848Pro Site Dataman 48Pro OPIKPto O T51Pro Search all Dataman 448Pro Site O Dataman 48Pro O MEMPro Dataman 40Pro s B ferify Program Erase paTaman jal LPT All port Addre Establish communication Automatic Manual peed DEMO Connect Serialization Filename Select DATAMAN 848PRO Site and then click on Connect button 4 Select site PG4UW v2 43 10 2007 universal control program for Dataman programmers p Load prj Save prj Edit DADRA Log window Processor Intel 15 6 2 Freq CID 5C25 C049 00 14 85 BE 61 4 Operating system Windows XP v Physical RAM memory 1024 MB gt gt 19 10 2007 14 46 45 Default programmer None scan Addresses hex s di Select site Dataman 848Pro Site 1 Dataman B48Pro Site 2 Dataman B48Pro Site 3 Dataman B48Pro Site 4 Dataman 848Pro Site 5 Dataman 848Pro Site 6 Dataman 848Pro Site 7 Dataman B48Pro Site 8 Serialization
25. d to the existing Log file e option Rewrite Log file sets usage of Log file Log file will be created after the first restart of Pg4uwMC For all other following executions of Pg4uwMC the existing Log file will be rewritten and new Log file will be created Data from previous Log file will be deleted e Checkbox Add date information to Log file name allows user to choose additional date information into Log file name When the checkbox is checked the program automatically adds current date string into Log file namethrough the following rules If log file name has format lt log_file_name gt lt log_file_extension gt The name with added date will be lt log_file_name gt lt yyyy mmm dd gt lt log_file_extension gt The new part representing the date consists of yyyy year mmm month and dd day Example Log file name is E Logs reportmc log The final log file name with added date will look like this July 7th 2007 E Logs reportmc 2007 jul 07 log Advanced options about Log file size limit e option Use Log file text truncating when file size limit is reached when checked the Log file size limit is on It means that when Log file size reaches specified value the part of text included in Log file will be truncated When the option is unchecked the size of Log file is unlimited respectively is limited by free disk space only e option Maximum Log file size specifies the maximum size of Log file in kBytes e option
26. e and IP address System date and time Welcome screen can be closed by clicking on button OK Administration of build in PC Introduction e DATAMAN 848PRO Stand Alone multiprogramming system is a powerful programmer equipped with Windows XP Embedded operating system OS There are two major kinds of administration of the OS network and local OS is configured with two users accounts e admin e operator Credentials for DATAMAN 848PRO Stand Alone multiprogramming system users are Login Password Administrator admin saadmin Operator operator saoperator Network administration Connecting to network OS in programmer is configured for operating with TCP IP network To obtain correct IP address the configured DHCP server must run in your local network when programmer is starting After programmer is started it will show Welcome About screen On bottom part of screen in line IP address is the address obtained from DHCP server 39 When IP address is equal to 127 0 0 1 then no network cable is connected DHCP server is not running when device start or other kinds of error occur refer to troubleshooting chapter Dataman D Pg4uwMe v2 43 10 2007 Universal stand alone multiprogramming system Web http www dataman com Programmer type Dataman 848Pro Number of Sites available 8 Operating system Windows XP 5 1 Build 2600 Service Pack 2 Processor Intel 6 15 11 Frequency 2400 2400 06 MHz Physica
27. for LV series e Configuration EE PROM XCFxxx XC17xxxx XC18Vxxx EPCxxx AT17xxx 37LVxx e 1 Wire E E PROM DS1xxx DS2xxx e PROM AMD Harris National Philips Signetics Tesla TI eNV RAM Dallas DSxxx SGS Inmos MKxxx SIMTEK STKxxx XICOR 2xxx ZMD U63x series e PLD Altera MAX 3000A MAX 7000A MAX 7000B MAX 7000S MAX7000AE MAX II ePLD Lattice ispGAL22V10x ispLSI1xxx ispLSI1xxxEA ispLSI2xxx ispLSI2xxxA ispLSI2xxxE ispLSI2xxxV ispLSI2xxxVE ispLSI2xxxVL LC4xxxB C V ZC M4 xx xx M4A3 xx xx MAA5 xx xx MALV xx xx e PLD Xilinx XC9500 XC9500XL XC9500XV CoolRunner XPLA3 CoolRunner Il eother PLD SPLD CPLD series AMI Atmel AMD Vantis Gould Cypress ICT Lattice NS Philips STM VLSI TI e Microcontrollers 48 series 87x41 87x42 87x48 87x49 87x50 series eMicrocontrollers 51 series 87xx 87Cxxx 87LVxx 89Cxxx 89Sxxx 89LVxxx all manufacturers Philips LPC series e Microcontrollers Intel 196 series 87C196 KB KC KD KT KR e Microcontrollers Atmel AVR AT90Sxxxx ATtiny ATmega series e Microcontrollers Cypress CY7Cxxxxx 8 e Microcontrollers ELAN EM78Pxxx e Microcontrollers MDT 1xxx and 2xxx series eMicrocontrollers Microchip PlCmicro PIC10xxx PIC12xxx PIC16xxx PIC17Cxxx PIC18xxx PIC24xxx dsPIC series e Microcontrollers Motorola Freescale 68HC05 68HC08 68HC11 HCS08 HCS12 series e Microcontrollers Myson MTV2xx 3xx 4xx and 5xx series e Microcontrollers National
28. ftware provides full information for ISP implementation Description of ISP connector pins for currently selected chip recommended target design around in circuit programmed chip and other relevant information For general definition recommendation and direction about ISP see section Common notes ISP please Description of ISP connector 2 4 6 8 10 12 14 16 18 20 mg m H 8 NH NH NH NH 1 3 5 7 9 11 13 15 17 19 B NH NH NH NH NH NH Front view at ISP connector Specification of ISP connector pins depends on the device which you want to work with You can find it in the control SW for programmer Pg4uw menu Device Device Info Ctrl F1 Note the ISP programming ISP option of respective device must be selected It is indicated by ISP suffix after the name of selected device These specifications correspond with application notes published by device manufacturers Application notes can be found on www dataman com Support Application Notes Note Pin no 1 is signed by triangle mark on ISP cable connectors DATAMAN 848PRO ISP cable Warnings e Use only ISP cable from delivery package When you use other ISP cable other material length programming may become unreliable e DATAMAN 848PRO can supply power to the programmed device pin 1 of ISP connector and the target system pin 19 and 20 of ISP connector with some limitations see Technical specification ISP connector e DATAMAN 848PRO appl
29. g When folder is selected Change dir button jump up from current directory one level one folder up Note The drive combo box is automatically refreshed each time it is dropped down It is useful for loading project files from USB key which can be plugged temporarily into USB port of standalone programmer and consequently new drive letter assigned with USB key will appear in list of available drives File Manage projects Manage project dialog offers two options Manage projects Please select one of following actions Copy project file from another location i to Projects folder Xx Delete project file from Projects Folder X Cancel 1 Copy project file from another location to Projects folder 2 Delete project file from Projects folder 26 Copy project file to Projects folder Delete project file from Projects folder Look in g Data Select project tile Directory g SProg files epri g Buldm epri L3 kSfta Bu m with ecc epri KSA gBulm with ecc eprj L1 mez8t amp 4 c3bb epri kSgBglBullm epr kSgBgUBulrm without it and id me28f640c3bb_it Directory E Projects Drive Data 71 171 MB of 74 651 MB free Drive Data 71171 MB of 74 651 MB free Change dir v Copy x Cancel Fic Info v Delete x Cancel When option 1 is selected
30. ies programming voltage to target device and checks its value target system can modify programming voltage If the programming voltage is different from expected no action with target device will be executed Note H L read driver H L driver R1 pin of ISP connector R2 read driver in programmer R3 PU PD driver in programmer R1 180R R2 1k3 R3 22k Selftest and calibration check Warning Selftest and calibration check can be run in engineering mode only This mode is available only when external display keyboard and mouse are connected to DATAMAN 848PRO If you feel that your programmer does not react according to your expectation please run the programmer ISP connector s selftest using Diagnostic POD Diagnostic POD for ISP connectors 2 enclosed in the standard delivery package Selftest of programmer e Insert 48 pin diagnostic POD type I into ZIF socket of the programmer Take care about orientation of 48 pin diagnostic POD type see top side of POD e Run selftest of programmer in PG4UW Programmer Selftest plus Selftest of ISP connector e Insert Diagnostic POD for ISP connector 2 into ZIF socket of the programmer Take care about orientation of Diagnostic POD for ISP connector 2 e Interconnect the 20 pin connector of Diagnostic POD for ISP connector 2 with the ISP connector of the programmer with the ISP cable included in delivery with the programmer package Be
31. ith standard text viewers e g byte 5AH is stored as characters 5 and A which mean bytes 35H and 41H One line of this HEX file one record contains start address and data bytes All records are secured with checksum Introduction DATAMAN 848PRO is extremely fast universal 8x 48 pindrive Stand Alone concurrent multiprogramming system designed for high volume production programming with minimal operator effort The chips are programmed at near theoretical maximum programming speed Block scheme of DATAMAN 848PRO external display Windows XP Embedded keyboard driven mouse high performance PC graphics control unit with touch screen optional DATAMAN 848PRO consists of eight independent isolated universal programming modules based on the DATAMAN 48PRO programmer hardware Therefore DATAMAN 848PRO sockets can run asynchronously concurrent programming mode Each programming module starts programming at the moment the chip is detected to be inserted in the socket properly independently of the status of other programming modules This results in seven programming modules working while you replace the programmed chip in the eighth Graphical control unit with touch screen provides basic control and easy monitoring of the programming flow Modular construction of hardware the programming modules work independently allows for continuing operation when a part of the circuit becomes inoperable It also makes service quick and
32. l RAM memory 1014 MB Computer name IEMAVvNHEXEY STZT IP address 182 158 0152 Remote control Administering of DATAMAN 848PRO Stand Alone multiprogramming system is performed through Microsoft Remote Desktop Connection Remote desktop offers fast and comfortable way to update software control software and system distribute project files Find and run Remote Desktop Connection program on your computer In Computer field enter IP address from Welcome screen of standalone programmer f Remote Desktop Connection Remote Desktop Connection Computer 192 168 0 149 v Connect Cancel Help Options gt gt When communication is established enter administrator credentials 40 Remote Desktop Connection Enter your credentials For 192 168 0 145 These credentials will be used when you connect to the remote computer User name admin v Password COD Cl Remember my password Because Windows allows only one user connected at a time next message may be showed Logon Message The user OEM ESP49TO3Z5LYoperator is currently logged on to this computer If you continue this user s Windows Session will end and any un saved data will be lost Do you want to continue Warning Connecting to programmer in time when programming devices is running programming will be immediately terminated your devices may not be fully programmed Restart computer af
33. lation package from the USB key When user confirms another confirmation dialog update process will start Pg4uwlAC Install software System is ready to install software PoduwMC v2 39 The LCD can be blank for some moments during installation Also restart of system will be performed automatically Press OK button to start installation e During update process control program of Stand Alone programmer is closed LCD panel can be blank for some moments and after installation is complete automatic restart of standalone programmer will be performed Whole process should not exceed time of 1 2 minutes 38 Help About Dataman D Pg4uwMe v2 43 10 2007 Universal stand alone multiprogramming system Web http www dataman com Programmer type Dataman 848Pro Number of Sites available 8 Operating system Windows XP v5 1 Build 2600 Service Pack 2 Processor Intel 6 15 11 Frequency 2400 2400 06 MHz Physical RAM memory 1014 MB Computer name DEMAvNHEXEY STZT IP address 182 158 0152 v OK Welcome screen is displayed on standalone s build in LCD screen after successful starting of standalone control software The screen can be also displayed by using menu command Help About Welcome screen contains following basic information version of control software programmer type number of Sites available operating system information about processor and size of installed RAM memory computer nam
34. les The rich featured auto increment function enables one to assign individual serial numbers to each programmed device or simply increments a serial number or the function enables one to read serial numbers or any programmed device identification signatures from a user created file The software also provides a lot of information about programmed device As an example the drawings of all available packages explanation of chip labeling the meaning of prefixes and suffixes on the chips 16 PG4UW v2 36 03 2007 universal control program for Dataman programmers File Buffer Device Programmer Options Help cct A r4 2 Edit Select def v s 4 s bd Davaman 29335300788 8 Log window uvue wore duos Statistics 2007 08 01 16 Success 08 Scanning port s for Dataman 448Pro Site 1 not found Total Scanning port s for Dataman 448Prot Site 1 not found m Scanning port s for Dataman 48Pro not found EC 11 S porvis Count down Disabled Scanning port s for Dataman 46Pro not found EC 11 f Reload Count down Count down Scanning port s for Dataman 40Pro not found Addresses hex Programmer Org Size Type Dataman 48Pro Device x8 888 8 2 Buffer x8 888 8 YES Manual x8 EN Split None CheckSum OOO7F800h Type unselected Serialization None Filename Make a project 1 Connect external display keyboard and mouse to PC conne
35. me non blank data is programmed or they use data with only a few 0 bits FE EF etc This deceptive approach can decrease programming times considerably If you plan to compare ask always which pattern they use e The programming speed depends on the PC speed only slightly SOFTWARE e Algorithms only manufacturer approved or certified algorithms are used e Algorithm updates software updates are available regularly approx every 4 weeks free of charge Internet download OnDemand version of software is available for high prority chip support and or bugs fixes Available nearly same day e Main features revision history session logging on line help device and algorithm information Device operations standard intelligent device selection by device type manufacturer or fragment of part name e automatic ID based selection of EPROM Flash EPROM e blank check read verify e program erase configuration and security bit program e illegal bit test e checksum e interpret the Jam Standard Test and Programming Language STAPL JEDEC standard JESD 71 interpret the VME files compressed binary variation of SVF files security e insertion test reverse insertion check contact check e ID byte check special production mode automatic start immediately after device insertion e lots of serialization modes more types of incremental modes from file data custom generator mode e statistics
36. ng on power The screen is shown during booting up of operating system and starting of standalone control software Pg4uwMC Welcome screen About screen Dataman D Pg4uwM 243 10 2007 Universal stand alone multiprogramming system Web http www dataman com Programmer type Diataman 848Pro Number of Sites available 8 Operating system Windows P 5 1 Build 2600 Service Pack 2 Processor Intel 6715 11 Frequency 2400 2400 06 MHz Physical RAM memory 1014 MB Computer name DEM WNHERXYST2T IP address 192 169 0152 Welcome screen is displayed on Stand Alone build in LCD screen after successful starting of standalone control software The screen can also be displayed by using menu command Help About for more information see Help About Welcome screen can be closed by clicking on button OK 23 LCD main screen Device Programmer Options Help Status Serialization Ready Ready Ready Ready Ready Ready Ready Ready Be serial value Good 0 Fal plone tdn Disabled Device Samsung 96860800 TEOP48 Project kSg8g08ullm epri Checksum 5 Pun Program x Stop Main screen consists of following parts Menu File Device Programmer Options Help Table with information about programmer sites site and serialization status Next serial value Statistics Recently selected device name
37. nly a software update because the DATAMAN 848PRO is based on the truly universal DATAMAN 48PRO programmer With our prompt service you can have new devices added to the current list within days Advanced design of the DATAMAN 848PRO Stand Alone multiprogramming system including protective circuits original brand components and careful manufacturing and long burning in periods allows us to provide a three year warranty on parts and labor for the programmer limited 25 000 cycle warranty on ZIF sockets Although we take as much care as possible to integrate high quality components for the built in computer we can t provide the same level warranty as we get from the suppliers of computer parts Therefore it is a limited warranty of one year for all computer parts such as motherboard CPU HD etc DATAMAN 848PRO elements 48 pin ZIF socket work result LEDs power sleep LED of site YES Button ISP connector graphical control unit with touch screen fan s grid 1 2 3 4 5 6 7 temperature controlled fans banana jack for connection to ground 10 banana jack for ESD wrist straps connection 11 Windows XP Embedded serial number sticker 12 PC connectors e g for display keyboard mouse 13 power switch 14 power supply connector 8 9 Manipulation with the programmed device After the selection of desired device for your work you can insert it into the open ZIF socket lever is up and close socke
38. on the programmer by the power switch placed at back side of programmer 3 When the built in computer is turned on the operating system will start booting up cooling fans should start to work and Please Wait screen should be displayed on graphical control unit 4 Starting of the operating system can take some time normally this time is shorter than 1 minute 5 After the operating system has successfully started the Pg4uwMC control program will start automatically When the Pg4uwMC is ready to work the Welcome screen is displayed on graphical control unit 6 Click the OK button on Welcome screen to continue The main screen with menus and Status panel should appear on graphical control unit 20 Checking if the sites are ready to be connected 7 When first starting Stand Alone multiprogramming system or when error message Programmer Sites not found is displayed then programmer software must be reinitialized by action Search for Programmers available in menu Programmer Search for Programmers 8 dialog Search for Programmers use button Search to search for present programmer sites The result of search will be displayed in table Search results in Search dialog When programmer sites are successfully found then programmer type and its serial number is show in the table Search result Detected programmer can be accepted by pressing touching Accept If no complete programmer was found then No P
39. ons and lt Alt S gt depend on the selected device C a 9 Save project click on and select destination folder write a description of project etc You can make a project on other DATAMAN programmers DATAMAN 48PRO too For more details see Help for PG4UW or Dataman PRO series manual The latest manual may be fiound at www dataman com Production mode Warning External display keyboard and mouse not needed in this mode This part of the software is focused on the easy monitoring of high volume production operations via graphical control unit with touch screen The user can control the following basic operations load project file connect disconnect programmer sites select desired device master operation blank check verify program erase start stop device operation on connected programmer sites Set some advanced options to customize available settings for example Automatic YES Function create Job report e create Problem report e copy project file s from external drive for example from network drive USB key etc to the standalone s local Projects folder e see the progress of device operation including statistics information serialization Step by step instruction Starting Stand Alone multiprogramming system 1 Check if the power switch placed at back side of programmer near power supply connector is on position 0 2 Plug the power cord into the programmer power supply connector and turn
40. or keyboard and mouse Do not use this menu option without these peripherals connected and working File Shut down computer Command is used to close control program and to shut down built in computer It is similar to command Shut down in Microsoft Windows operating systems Menu Device File Device Programmer Options Help Blank Check gerialization verify 3 H4 BProgram Lis Erase HE HF HB Good 0 Fai Ctdn Disabled Device Samsung K3G8GU08U0M 50 48 Project k998g08u0m eprj Checksum 7 serial value of Run Program 6 Stop Device Predefined operation This menu allows user to select device Master operation Following Master operations are available e Blank check e Verify e Program e Erase 28 Each Master operation can consist of a sequence of one or more partial operations for example Program device operation can consist fof the following sub operations 1 Erase 2 Program 3 Verify Selection of sub operations is stored in Project file For details about project file creation and usage refer to Engineering mode chapter Preselected device operation can be started by button Run lt operation_name gt displayed on main screen Menu Programmer File Device Programmer Options
41. phone fax e mail e free lifetime software update via Web site Programming a device DATAMAN 848PRO can operate in two modes Engineering mode for creating a project Production mode for mass production Engineering mode Warning This mode is available only when external display keyboard and mouse are connected to DATAMAN 848PRO To switch to Engineering mode use File Switch to Engineering mode This part of the software is focused on the quick and easy preparation of the project file for use in the production mode of the control software Each programming module is driven by an easy to use control program with pull down menu hot keys and on line help Selecting of the device is performed by its class by manufacturer or simply by typing a fragment of vendor name and or part number It is the same time proven software as is used for other Dataman single site programmers Engineers can use all properties of this software and can make a project for mass production Standard device related commands read blank check program verify erase are boosted by some test functions insertion test connection check signature byte check and some special functions autoincrement production mode start immediately after insertion of chip into socket All known data formats are supported Automatic file format detection and conversion are done during loading of file It is possible to use Jam files JEDEC standard JESD 71 and VME fi
42. project refer to the chapter Menu File and Load project When Load project operation is successfully done for all Sites the Ready status must be displayed in panel Status on touch screen for all connected Sites If there are some Sites with different status use troubleshooting documentation to resolve the problem Selection of predefined device operation 16 Use menu Device Predefined operation to select device Master operation Following Master operations are available Blank check Verify Program Erase For more details about predefined device operations see chapter Menu Device Predefined operation Insertion of devices in programmer sockets and start device operations 17 Insert devices into programmer sockets and press Run operation button on touch screen operation means predefined operation for example when 21 predefined operation is Program device the caption of button Run will be Run Program 18 Selected device operation including sub operations that are part of predefined device operation will start Progress of operations is displayed in panel status for each programmer site You can use some special features of Stand Alone multiprogramming system for example Count down or Statistics 22 Software Detailed description of Graphics user interface with touch screen Please Wait screen Please Wait screen is displayed on standalone s built in LCD screen as the first screen after turni
43. rogrammers found message will be displayed in table Search results and button Accept will be disabled 9 f search result is No Programmers found please try to turn off Stand Alone programmer by menu File Shut down computer turn off the power button on the back Side of programmer wait for 15 seconds or more and start programmer again If the search result is still No Programmers found please refer to troubleshooting documentation Starting programmer sites 10 Each programmer site uses its own hidden control application Pg4uw 11 To start the hidden applications of control programmer sites use menu Programmer Connect Sites 12 The Connecting sites indicator is displayed during connection of sites Additional information about site connection progress is displayed for each site in panel Status on main screen 13 Programmer sites are numbered from 1 to 8 in direction of physical placement of programmer sites from left to right 14 When connection process of programmer sites is complete indicator Connecting Sites will be hidden Panel Status will contain information about each site Loading project file 15 When site status after connection is Ready or No project file is loaded user can begin the Load project operation accessible from menu File Load project The project file can be loaded from default directory Projects or from any other location for example from USB key For more details about Load
44. s Programmers successfuly detected on USB Connecting Programmer Sites 1 SITE 1 07 14 31 Quick Selftest Command displays content of current Log window At top right corner is the button x which is used for closing the Log window and displaying of main screen Options Protected mode Protected mode is special mode of the program When the program is in Protected mode there are disabled certain program operations and commands Protected mode is used to prevent the operator from modifying program or device settings due to insignificance Protected mode is suitable especially for the programming of a large amount of the same type of devices 36 Protected mode can be activated by this menu option or by loading project file that has activated Protected mode Protected mode settings are saved to configuration ini file of Pg4uwMC During next start of program Pg4uwMC the Protected mode settings from ini file are used When Protected mode menu command is used password dialog will appear User has to enter password twice to confirm the password is correct After successful password confirmation program switches to Protected mode File Device Programmer Options Help Site Status Serialization Set password for Protected made Password Confirm password Cancel Keep Load project operation allowed Checksum ee wl wv Pun Program X Suo There i
45. s also available one special option Keep Load project operation allowed The option is set to disabled at default it means the Load project operation button and menu will be disabled when Protected mode is active If the option is enabled checked the Load project operation button and menu will be allowed in Protected mode To switch program from Protected mode back to Normal mode use the menu command Options Normal mode The Password required dialog appears User has to enter the same password as the password entered during switch to Protected mode When Protected mode is active the label Protected mode is visible near the top of Status table of main LCD screen Notes Sometimes when Protected mode is switched from active state to inactive state Normal mode some commands for example command Load project may remain disabled This can be resolved by clicking on button Stop When user forgot the password to turn off Protected mode then protected mode can be turned off by administrator by entering Administrator password Administrator login is not necessary Menu Help Help Index Menu command displays short help on built in touch screen The short help contains brief information about menu commands and basic operations with usage of touch Screen Help Problem report Menu command Create problem report is used for writing more particular diagnostic information to Log window and consequently copy Log
46. s will be distributed with operating system updates For programmer reliability operating system is configured with write filters on Recovery and System disk As a side effect of these filters any configuration changes in entire operating system will be wasted after restart or shutdown programmer Operating system recovery Recovery OS performs refreshing of programmer operating system to state as it was shipped from factory Before operating system recovery connect monitor to programmer and kindly report what you see to programmer manufacturer To perform operating system recovery you must have connected keyboard mouse and display Turn on programmer Starting BIOS screen will show Award Modular BIOS v6 00PG An Energy Star Ally Copyright C 1984 2006 Award Software Inc Intel G965 BIOS for 965GM DS2 F1 lt DEL gt BIOS Setup Q Flash lt F9 gt Xpress Recovery2 lt F12 gt Boot Menu 10 12 2006 G965 ICH8 6A79LGOPC 00 After this screen Windows show next Choose an operating system to start Use the arrow keys to highlight your choice then press ENTER windows XP Embedded Recovery With arrow keys up or down select Windows Recovery and press Enter Recovery system will be started Please be patient This can take about four minutes Then EULA license will show Please read carefully this license agreement close window press A if you accept this agreement 42 Accepting
47. sure that the pins are interconnected properly i e 1 1 2 2 20 20 e Run selftest of ISP connector in PG4UW Programmer Selftest ISP connector 10 Technical specification Specification DATAMAN 848PRO multiprogramming system 8x universal programming module 8x 48 pin DIL ZIF sockets and 8x ISP connector operation result LEDs LED power e line power input 100 240VAC 60W max e banana jack for ESD wrist straps connection e banana jack for connection to ground Specification PC system inside of programmer e Microsoft Windows XP Embedded operation system e PC Intel Core 2 Duo 2 4 GHz e 1024 MB RAM e 160 GB HDD SPECIFICATION valid for each programming module HARDWARE Base unit DACs e USB 2 0 high speed compatible port up to 480 Mbit s transfer rate e on board intelligence powerful microprocessor and FPGA based state machine e three D A converters for VOCP VPP1 and VPP2 controllable rise and fall time e VCCP range 0 8V 1A e VPP1 VPP2 range 0 26V 1A autocalibration selftest e selftest capability Socket pindriver e 48 pin DIL ZIF Zero Insertion Force socket accepts both 300 600 mil devices up to 48 pin e pindrivers 48 universal VPP1 VPP2 can be connected to each perfect ground for each e FPGA based TTL driver provides H L CLK pull up pull down on all pindriver pins analog pindriver output level selectable from 1 8 V up to 26
48. t lever is down The correct orientation of the device in ZIF socket is shown on the picture near the ZIF socket on the programmer cover The programmed device must be remove from the socket when the BUSY LED is off Note Programmer protection electronics protect the target device and the programmer itself against either short or long term power failures and partly against a PC failure However it is not possible to gurantee the integrity of the target device due to incorrect user selected programming parameters Target device may not be destroyed by forced interruption of the control program turn off programmer but the content of programmed cells may remains undefined Don t unplug the target device from the ZIF socket during work with device BUSY LED on In system serial programming by DATAMAN 848PRO Optimized advanced pindrivers deliver programming performance without overshoot or ground bounce for all device technologies Pin drivers operate down to 1 8V so you ll be ready to program the full range of today s advanced low voltage devices The ISP programming solution performs programming verification at the marginal level of supply voltage which obviously improves programming yield and guarantees long data retention The ISP programming solution provides also the power supply for the target system This ISP programming solution provides very competitive price but excellent hardware design for reliable programming The so
49. t file is loaded means the site is successfully connected but no project file is loaded It also means that no device is selected The recommended action is Load project e other text describes current status of site s Programmer Disconnect Sites Menu command is used to disconnect all programmer sites and close Programmer sites control applications The command will apply only if no device operation is currently running on any of connected sites The command does not close main control program Also Stand Alone programmer computer remains running Programmer Automatic YES Command displays dialog Site settings with Automatic YES options Site settings Automatic YES Un n tf 2 Use Project settings m4 x Cancel Three modes of Automatic YES function are available 30 e On Automatic YES Is always On Off Automatic YES Is always Off e Use Project settings Automatic YES setting depends on relevant settings stored in project file When Automatic YES mode is On programmer sites are scanning their device sockets after device operation is completed The control program can detect removing of programmed device and insertion of new device and afterwards automatically start repeat recent operation on new device So operator does not need to press any key or button to program next device When Automatic YES mode is Off operation on next device can be started manually b
50. t have to be used Each site is represented by one check box If the check box n is checked it means the site n is selected and device 31 operations will run on it If the check box n is unchecked the site n is unselected so no device operations will run on the Site The sites can be set as selected or unselected anytime needed except during running device operation Menu Options File Device Programmer Options Help Site Status lization 1 He HS Statistics 4 5 View Log HF Ha Protected made Mext serial value S Lacer es Fait Disabled Device Samsung KIG8G08U0M TSOP48 Project k998g08u0m eprj Checksum Em ww Pun Program x Stop Options Settings Command displays dialog Settings with list of options user can choose from and set their properties and or settings gt Job Report gt Display settings gt TouchPad calibration gt Sounds v Select x Cancel Log file Log file settings screen looks as following Log file Log file settings Rewrite Log file Append Log file Log file name E Logs reportme log Add date information to Log file name Log file size limit v Use Log file text truncating when file size limit is reached Maximum Lag file size 4000 kB 200 kB 2
51. tally reconfigurable 48 powerful TTL pindrivers provide H L pull_up pull_down and read capability for each pin Advanced pindrivers incorporate high quality high speed circuitry to deliver signals without overshoot or ground bounce for all supported devices Pin drivers operate down to 1 8V so you ll be ready to program the full range of today s advanced low voltage devices DATAMAN 848PRO performs on each programming module device insertion test wrong or backward position and contact check poor contact pin to socket before it programs each device These capabilities supported by overcurrent protection and signature byte check help prevent chip damage due to operator error DATAMAN 848PRO has the selftest capability which allows the diagnostic part of software to thoroughly check the health of the each programming module DATAMAN 848PRO has a built in protection circuit for eliminating the damage of programmer and or programmed device due to environment or operator failure All ZIF socket pins of DATAMAN 848PRO programmer are protected against ESD up to 15kV DATAMAN 848PRO performs programming verification at the marginal level of supply voltage which obviously improves programming yield and guarantees long data retention Various socket converters are available to handle devices in PLCC SOIC PSOP SSOP TSOP TSSOP TQFP QFN MLF SDIP BGA and other packages It is important to remember that in most cases new devices require o
52. ter you finish remote administering Because work with remote desktop is similar to working on local station please continue to read chapter Local administration Local administration For local administration of Stand Alone programmer you must have connected standard PS 2 keyboard PS 2 mouse and standard analog display with resolution 1024x768 and 32bit color supported Operating disk is divided to three volumes First volume named as Recovery C contains software for OS recovery of programmer to state as shipped from factory Standard start time of programmer is about 2 minutes When device doesnt start in 10 minutes then it may be necessary to perform OS recovery Before operating system recovery connect monitor to programmer and kindly report what you see to programmer manufacturer For next steps refer to Operating system recovery chapter Second volume is System D and contains Windows XP Embedded operating system 41 Warning Do not delete change files or perform any writes on Recovery or System disk volumes Third volume is named as Data E This volume contains Programmer Projects Logs Updates and Temp directories Programmer is directory where main control software is installed In directory Logs are saved log files from operations with devices When OS update files are available they should be saved to Updates directory Your project files should be in Projects directory Exact update step
53. the dialog with list of project files at specified drive and folder will appear User can select desired drive folder and project file and copy the selected project to the Projects folder by clicking on Copy Change dir button is used to change current directory to directory selected in Directory list on the left side of dialog When folder is selected Change dir button jumps from current directory one level one folder up Note The drive combo box is automatically refreshed each time it is dropped down It is useful for loading project files from USB key which can be plugged temporarily into USB port of standalone programmer and consequently the new drive letter assigned with USB key will appear in list of available drives When option 2 is selected the dialog with a list of project files present in Projects folder will appear User can select desired project and delete selected project by clicking on Delete button The dialog can be closed by Cancel button Also basic information about selected project file can be displayed by clicking File info button File Make Job Report Job Report Samsung K9G8GOBUOM TSO Dataman Job Report created at 2007 10 22 year month day 09 09 02 Project Name E lProgrammerlk3g8g08u0m eprj Project Date 2007 06 27 15 47 44 Protected Mode Disabled Software Revision PgduwMC ver 2 43 10 2007 Programmer Dataman 848Pro Job Start Time 2007 10 22 07 17 02 Job End Time
54. x Enable Count down sets Count down activity enable or disable Edit box following the Enable Count down check box defines initial number of count down counter from which count down starts Actual statistics values are displaying in main window of control program in Statistics panel Statistics panel contains three statistics values Good Fail Total two Count down information values Ctdn status and value Meaning of the values is Good number of operations which where successfully completed Fail number of operations which where not successfully completed Total number of all operations Ctdn informs about Count down activity En enabled or Disabled Remains informs about remaining number of device operations to do Notes When project file is loaded all statistics values are set to zero and Ctdn is set to Disabled For multiprogramming Pg4uwMC software the statistics information is also saved to Job Summary report Options View Log Log file x Welcome to Dataman Pg4uwMcC Multiprogramming Control A Version 2 43 10 2007 Today is 22 10 2007 09 03 50 Processor Intel 6 15 11 Frequency 2400 2400 04 MHz Operating system Windows XP v5 1 Build 2600 Service Pack Physical RAM memory 1014 MB gt gt MC Log file created at 22 10 2007 09 03 51 Log file name E lLogs veportme log Log file mode New rewrite gt gt 22 10 2007 07 14 19 Searching for connected programmer
55. y pressing the YES button near each programmer site Each programmer site has its own YES button Status of the active Automatic YES function is displayed on the bottom left side of LCD main screen with label Automatic YES Is On by following File Device Programmer Options Help Site Status Serialization 118 Please insert a new device into sock Please insert a new device into sock Please insert a new device into sock 1 Please insert a new device into sock Please insert a new device into sock 1 Please insert a new device into sock Please insert a new device into sock itd Please insert a new device into sock Mext serial value Curatistice EXEUNT ioni ail otal f Nene Disabled Device Macronix MX2BFBADC3BB 50 48 Project mx28f640c3bb eprj Checksum 7F300000h Progam Stop If the Automatic YES function is Off no label about Automatic YES is displayed For more details about Automatic YES feature see documentation chapter Programmer Automatic YES Programmer Select Enabled Sites Command displays dialog Select Enabled Sites Select Enabled Sites Enabled Sites Site 1 v Site 2 Site 3 v Site 4 Site 5 v Site 6 Site 7 Site 8 v OK x Cancel This dialog is used to select sites tha