Home

Installation Manual VID-W03L040 Vista Infra-Red

image

Contents

1. Installation Manual VID W03L040 Vista Infra Red Detector Medium Range Curtain A Detector for Outdoor Perimeter Protection Manual VID W03L040_1 2008 doc page 1 10 www norbain co uk Table of Contents Page 1 MOGUCOM cts weisers test E cep ees eect E E E EEE 3 A E cnc scene atatnas eae eueeas samen cee eees pu neauaneeentsindemsuwenegeisesysdsnauiinesaeugenantoceesoaisseecantaneas 3 m Gap Free Coverage with Creep ZONES ccccccccecccceececseeeecaeeeecaeceeseeeeaecesseeeesseeeeseeeeeseeeeseeeeessueessneseesgeeeeas 3 E 4 Meter 13 Feet Mounting Height snannnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnn nnmnnn mnnn nnna 3 M Advanced Tamper Detection c csccccssssecseeseeeeesseecesseeseesseeeenseeseaseeeeensesoesseeeenseesensseseonseenonseneaes 3 E Low Power Consumption Ideal for Wireless and Solar Applications ssccceesseeseeseeees 3 M Wide Power Supply RANGGC c ssscccnnscsssccsnsessecnsnseseecnsesnecensesseecnnssseennssssecnosesecenenassssensessseenenesees 3 m Integrated Bracket for Wall MOUNTING ccccceeseeseeeseeeeeneeseeseeseeaseeeoeseseeeseseeaseesonseesoeanesensessons 3 3 M o ning and IS TAN AON saeesccsecce cee eeccceeres secemeevensepemsenide nas eeceecensesensai esses ease sosserccsevedesasweexsensvsnswceetes 3 4 Connecting the VID WOSLO040 cc cseesseeeeensseeeeensseeeceassesesonsseeeconsseeesonssesooonsseseoonssssenonasees
2. Height Advanced Tamper Detection Low Power Consumption Ideal for Wireless and Solar Applications Wide Power Supply Range Integrated Bracket for Wall Mounting 3 Mounting and Installation The mounting structure should be sold enough to resist significant movement in windy conditions Movement of the VID W03L040 caused by vibrations or other movements will result in changing fields of view covered by the VID WO03L040 and could cause erratic signals These unwanted signals may lead to an increase in the alarm threshold level which reduces the detection probability or in certain cases can lead to unwanted alarms The stainless steel bracket is ideally suited for wall mounting For pole mounting the VID PA is available the pole mount bracket comes with two strap bands for poles with diameters of 4 16cm For further information please refer to 15 2 It is very important that the cover of the detector is tightened securely Tighten the two screws to the point where it cannot be tightened further with reasonable force There should be less than 1mm gap between the cover and the bottom part of the housing The detectors are fitted with two M16 cable entry points The nut on the cable entry assembly should be tightened to clamp the cable in place If the cable diameter is too small to be held properly insulation tape should be wound around the cable to increase the outside diameter to a suitable size 4 Connecting the VID W03L040 For
3. the definition of the electronic board and terminal block see appendix 18 1 5 Alarm Signalling There are two types of alarm outputs on the VID W03L040 one SPST potential free relay contact one open collector transistor output Cover Switch A tamper detection switch is fitted for the cover this contact opens when the cover is opened 6 Field of View The VID W03L040 has a curtain shaped field of view with differential detection areas For the nominal range and width at that range see table below VID W03L040 Nominal Range 40m 130 feet Width at Nom Range 3m 10 feet 7 Alignment The detection range of a PIR detector is not limited but it is a function of the target size soeed and temperature contrast against its background The VID WO03L040 should be aligned so that a natural or artificial background at the end of the range terminates the field of view Vertical alignment is optimal when the upper edge of the field of view is at 1 5 to 2 5m 5 to 8 ft above ground at the end of the required detection range Use the grove on the top of the detector for correct alignment This line of sight corresponds to the upper edge of the detection pattern To limit the detection range a terminating screen can be used to prevent detection of targets beyond the required range Manual VID W03L040_1 2008 doc page 3 10 www norbain co uk 7 1 Vertical alignment of VID W03L040 for a required detection up to nominal range The VID W
4. 03L040 should be aligned vertically so that at a minimum the lower half of a person standing upright at the maximum required range will be within the field of view see Fig 1 below Side view OO o _ _ a _ _ _ _ _ 1 5 m 5 ft 0 1m 3 3 ft Nominal Range Fig 1 7 2 Horizontal alignment of VID W03L040 Horizontal alignment should be done in a way to avoid unwanted signals being generated by miscellaneous objects branches bushes and fences etc that are likely to be moVID by wind see Fig 2 below Movement within the field of view will reduce the sensitivity of the VID WO03L040 by increasing the alarm threshold level and may also lead to unwanted alarms Top view D eA O E ESS D n ____ e 7 aar e r Width The width of the zone at ground level near the detector is in the order of 1 6m 5 5 ft edge to edge when the detector is mounted at a height of 4m 13 ft This means that special care has to be taken when mounting a detector onto a wall and aiming along the wall in order not to pick up disturbances caused by air turbulences along the wall 8 Sensitivity Settings The settings of the VID W03L040 are adjusted by means of multiple DIP Switches on the printed circuit board The DIP Switches 1 and 2 are for setting sensitivity depending on the required detection performance If
5. D indicates correct connection and power 3 Antenna To be placed straight in the detector housing Manual VID W03L040_1 2008 doc page 6 10 www norbain co uk 15 2 Pole Mount Adapter VID PA Pole mounting bracket with two strap bands for poles of 4 16cm 1 6 6 25 diameter Da 16 Maintenance The detector has been designed to be virtually maintenance free but the following precautions are recommended 1 2 3 Visual inspection of the front window for accumulation of dirt on the outer surface or damage to be carried out at approximately 6 monthly intervals Clean the surface with a paper tissue and avoid rubbing dirt into the surface Walk tests for checking the detector alignment and sensitivity settings to ensure optimal performance and reliability Inspection is recommended following extreme conditions such as snow storms sand storms hail etc to make sure that nothing has been damaged and the sensitivity is not reduced by accumulation of snow sand or dirt on the front window Snow or dust in front of the window should be remoVID by hand or by using of a soft instrument 17 General Comment on the VID W03L040 Despite the advanced design and state of the art features of the VID W03L040 it is in the nature of a Passive Infrared Detector that an absolute detection probability and freedom from nuisance alarms cannot be achieVID masking of the VID W03L040 cannot be excluded Detection is a function of
6. hout limitation loss of business loss of profits or loss of data arising out of your use of the products Without limiting this general disclaimer the following specific warnings and disclaimers also apply Fitness for Purpose You agree that you have been provided with a reasonable opportunity to appraise the products and have made your own independent assessment of the fitness or suitability of the products for your purpose You acknowledge that you have not relied on any oral or written information representation or advice given by or on behalf of Vista or its representatives Total Liability To the fullest extent permitted by law that any limitation or exclusion cannot apply the total liability of Vista in relation to the products is limited to i in the case of services the cost of having the services supplied again or ii in the case of goods the lowest cost of replacing the goods acquiring equivalent goods or having the goods repaired Indemnification You agree to fully indemnify and hold Vista harmless for any claim cost demand or damage including legal costs on a full indemnity basis incurred or which may be incurred arising from your use of the products Miscellaneous If any provision outlined above is found to be invalid or unenforceable by a court of law such invalidity or unenforceability will not affect the remainder which will continue in full force and effect All rights not expressly granted are reserved 23 Wa
7. ith the unit powered on the detector determines its alignment position and after 5 minutes stores this value without the detector being in permanent alarm state The anti vandal function is activated by setting DIP Switch 6 to on Switch 6 AVF off on Factory Setting 12 LED The electronic board is fitted with a dual LED having a red and green colour side This can be monitored during installation while the cover is open m The red LED on indicates that the detector is in an alarm state z The green LED flashing at 2 Hz frequency indicates the detector ready state During the turn on time the red LED is on Manual VID W03L040_1 2008 doc page 5 10 www norbain co uk 13 Alarm Time Alarm time per event is determined by the duration of the detected event and depends on the shape and amplitude of the alarm signal Individual alarm pulses have a minimum time of approximately 2 5 seconds 14 Internal Temperature Compensation The VID W03L040 is detecting the radiation differences of a target against its background In the course of a day and a year the contrast of a person will vary considerably and affect the signal strength To compensate for this contrast variation the VID W03L040 has an internal temperature compensation with maximum sensitivity setting of approximately 30 C where the contrast of a human target is weakest and gradual reduction at higher and lower temperatures When installing a unit the inte
8. n co uk 18 Appendix Electronic Board and Terminal Block 18 1 Terminal Block Normally closed Output Transistor OC Not used GND Supply voltage 10 5 30 VDC 24V AC B Not used Not used Relay shown in energised non alarm condition 18 2 Dip Switches Sensitivity Function Switches SW1 SW2_ Function SW Function HW setting 75 HW setting 40 6 Anti vandal function Manual VID W03L040_1 2008 doc page 8 10 www norbain co uk 19 Appendix Specification Model S S CSDWOBLOQO i 2 5 4 0m 8 13 ft Sensor Pyroelectric differential single channel Front Window PE Filter IR transmissive saa Agusimeni DIP switches wel TAE Heavy duty plastic Colour white Weight app 900 g 2 0 Ibs incl mounting bracket Cable Feeds 2 x M 16 with cable clamp Outer Cable Diameter 4 5 10 mm 0 18 0 40 inch trical Supply Voltage 10 5 30 V DC 24 V AC 15 30 V DC 100 mA Terss 20 C 60 C 4 F 140 F Humidity 95 RH max Sealing IP 64 splash proof Operating Temperature 19 1 Mechanical Dimensions Dim in mm Manual VID W03L040_1 2008 doc page 9 10 www norbain co uk 20 Disclaimer The contents of this document are provided on an as is basis No representation or warranty either express or implied is made as to the completeness accuracy or reliability of the contents of this document The manufacturer
9. rd and Terminal BIOCK cccccseseeceeseeseenseesenseeceeneeseenseesenseeseeneesones 8 MO TAN OG anse E NE AES E EEN EN EE NE EEE AE EA EES 8 S DIDONE aan E E E N E AE E E E E EEE E A AE EE S 8 19 Appe ndix Specificati IM sci cee cocecite cece eats rercce anaa ene discon eneeesncceenicideceseaweteveewsbodecedecnweceausesecx 9 19 1 Mechanical DIMENSIONS ccccccceeeceeeceeeceneceneceneceu ees ecsecceueceeeceuecsuecsueceuecsuecegeceuecsaeesueeseseeueesaeeseeeseeenes 9 20 MNS SN AUN cate aca eee annie wee E AT E E 10 21 General Warning sssrin aE aSa aa A E aa EE a EEEE ENE NE E 10 22 LAOU eos E EEE EEEE e 10 23 Wairanty and Servic sisisi a i TOES a a aaia 10 291 PACIO SOVICO erir E Ee N E 10 ZZ ACORN AOUE Sn EE E E EE E E E 10 Manual VID W03L040_1 2008 doc page 2 10 www norbain co uk 1 Introduction The VID W03L040 is a highly sensitive Passive Infrared Detector designed for detection outdoors with a narrow curtain shaped differential field of view It incorporates microprocessor controlled signal processing including signal shape analysis adaptive threshold level by feedback of environmental effects temperature compensation and rejection of disturbance signals Sensitivity adjustments are done with DIP Switches for each individual unit in function of the required detection range in order to adapt to the specific needs of an installation 2 Features Gap Free Coverage with Creep Zones 4 Meter 13 Feet Mounting
10. reserves the right to change designs or specifications without obligation and without further notice Except as otherwise provided all warranties express or implied including without limitation any implied warranties of merchantability and fitness for a particular purpose are expressly excluded 21 General Warning This product must only be installed configured and used strictly in accordance with the General Terms and Conditions User Manual and product documents available from Vista All proper health and safety precautions must be taken during the installation commissioning and maintenance of the product The system should not be connected to a power source until all the components have been installed Proper safety precautions must be taken during tests and maintenance of the products when these are still connected to the power source Failure to do so or tampering with the electronics inside the products can result in an electric shock causing injury or death and may cause equipment damage Vista is not responsible and cannot be held accountable for any liability that may arise due to improper use of the equipment and or failure to take proper precautions 22 Liability You agree to install configure and use the products strictly in accordance with the User Manual and product documents available from Vista Vista is not liable to you or any other person for incidental indirect or consequential loss expense or damages of any kind including wit
11. rnal temperature may take up to 30 minutes or more to stabilise to the actual external temperature Sufficient time should be given to the VID WO0O3L040 to reach the correct internal temperature and sensitivity before performing walk tests During the initial period of operation it is strongly recommended that walk tests are repeated under various weather conditions such as high and low temperatures wind fog snow rain etc to obtain comparative data and information on the effects of environmental conditions on detection and nuisance alarm probabilities for this particular site Fine tuning of the detector based on this data by changing the sensitivity settings may optimise the performance 15 Accessories 15 1 Cordless Walk Tester VID WT The cordless walk tester VID WT is an accessory for remotely checking the detector alignment During a walk test it indicates a detection alarm with a beeper and a LED The walk tester VID WT consists of a transmitter VID WT T and a receiver VID WT R For further information regarding the use of the VID WT please refer to chapter 10 15 1 1 Receiver LED Description Power LED indicates power is on and battery o k dims when voltage is low Comm LED indicates communication with transmitter is o k Alarm LED lights up as long as alarm is activated 15 1 2 Transmitter Description eet Power and Communication plug This plug connects to the detector s test socket 2 Power LED LE
12. rranty and Service 23 1 Factory Service If the unit requires factory service contact the dealer who supplied the unit to you for the correct procedures on returning the unit to the factory or the nearest factory service centre If the dealer is not available contact the manufacturer of the unit as detailed below and request a Return Material Authorization number RMA The units serial number must be provided before a RMA number can be issued Units returned to the factory for service must have freight and insurance prepaid and must show the RMA number clearly on all shipping documents The failure symptoms must be clearly described by the operator and enclosed with the unit together with a copy of the original suppliers invoice Failure to comply with these instructions will delay service of the unit and may result in the unit not being accepted by the Repair Centre 23 2 Factory Address Vista Norbain House Eskdale Road Winnersh Triangle Wokingham Berkshire England RG41 5TS www norbain co uk Telephone 44 0 118 944 0123 Fax 44 0 118 944 0999 Manual VID W03L040_1 2008 doc page 10 10 www norbain co uk
13. soooans 3 5 AMM SNAN cers s nite ess eee ee we cee E te eee cee dee ees Eea EE 3 6 NON OR VN OW atc cis eie E E ese vasaaeneeucetcecusetensceemeapn tee sueeupeneseees 3 M Net eee cree E rc cece ce oe xe see tome nme se eee tee scene O ence E E E E 3 7 1 Vertical alignment of VID W03L040 for a required detection up to nominal range cceeeeeeeeeeeeeeeeeees 4 7 2 Horizontal alignment of VID WO3LO040 o oo cccecccccceeeeeeeeeeeeeeeeeeeeeeseeeeeeseeeeeeaeeeeesseaeeeesaaeeeessaueesesenseeeaaaes 4 B lt SEMSIIVITY SENINGS sicrie aa aE a Ea enescacressctedeutectvsncccussecantecsens 4 9 Adaptive Threshold Discrimination ATD ccccccssessesseseseeceseeceseeeensesonseeoessesensesensesonsesseneees 5 10 ToS E AEA e Ea AEEA T 5 11 Anti Vandal Function AVF wicisissscisnstiscnidewecccesdesatstunccassssatcasacandecsmucniesetwadcawadasdenscesscaavcadawenadinneanes 5 T LED ea E EOE event eceuaanewenespeuseeeeuee 5 O Aam TNE ee A E E 6 14 Internal Temperature Compensation ssusnnnunnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnn nnmnnn mnnn 6 TS ACOSSUS rrn A E a 6 ISA SSORGICSS Wak Tes er viO Terna EEA OEE EAEE 6 Aa IROCO O a E E E E EE EE E 6 Dice e A AA O r E EEE E EEEE E A E EAE A 6 192 Pole Moun Adapter VID PA sasea a e AE AO Eae T 19 Maint nahte sesona Ea a AE EEE 7 17 General Comment on the VID WO3LO040 ccccceceeeeeeeseeeeneecenseeeeseseansecanseceaseeeassseanseseaseseasesoases 7 18 Appendix Electronic Boa
14. the maximum required range is less than the nominal range of the detector a reduction in the overall sensitivity is recommended to reduce nuisance alarms Overall Sensitivity 40 75 100 Factory Setting Not used Manual VID W03L040_1 2008 doc page 4 10 www norbain co uk 9 Adaptive Threshold Discrimination ATD The background noise is constantly averaged and used to adjust the threshold levels for the alarm This special feature reduces the probability of nuisance alarms caused by wind moving vegetation or objects that have a thermal contrast usually weaker than that of a person Each signal exceeding a certain minimum value will activate the ATD and increase the threshold levels depending on its strength The time constants for increase and decrease are chosen in a way to adapt to gradual changes Signals generated by a person moving within the specified speed range however are strong enough for detection Repeated movement of any kind within the field of view is therefore activating the ATD reducing the overall sensitivity This has to be noted particularly when walk testing the following installation The DIP Switch 3 is used to activate or deactivate the ATD Adaptive Threshold Discrimination Switch 3 ATD off on Factory Setting Operation of the VID W03L040 in this mode is possible but not recommended in outdoor applications as the nuisance alarm rate could increase significantly as a result of t
15. thermal contrast speed and size of a target crossing the detectors field of view Contrast conditions can vary significantly in the course of the day and year Detection depends also on the sensitivity settings the exact aiming and the prevailing weather conditions as well as the nature of the target and background The detection pattern and frequency response of the VID W03L040 has been optimised for the detection of a human target crossing the field of view in an upright position at speeds in the range of 0 2 5 0 meters second Detection of slow moving targets at long ranges may become difficult under weak contrast conditions Limiting the zone length is strongly recommended to less than the nominal range when human targets moving at the minimum specified speed need to be detected with a high probability of accuracy Animals or crawling people may or may not be detected depending on their size speed contrast and distance from the detector It is therefore strongly recommended to combine the VID W03L040 with alarm verification such as CCTV or a second system using other physical means of detection e g VMD Any liability for direct or indirect damage resulting from the use of the VID W03L040 as a detection device is explicitly disclaimed The information in this product manual is based on testing of samples taken at random from production and believes to be representative E amp OE Manual VID W03L040_1 2008 doc page 7 10 www norbai
16. urbulences When the unit is walk tested the threshold level will increase as a result of the signal generated by the target it will subsequently decrease exponentially in time after the event To make sure that original sensitivity is reached wait at least for 3 minutes between each crossing walk test or disable the ATD function by setting DIP Switch 3 to off The DIP Switch 4 has no function in this model 10 Test When conducting a walk test using the VID WT DIP Switch 5 needs to be set to on On completion switch test to off Switch 5 Test off Factory Setting on The VID WT s transmitter has to be placed within the housing with the detector cover closed and securely tightened The antenna of the transmitter needs to be placed vertically or horizontally in the detector housing 11 Anti Vandal Function AVF The VID W03L040 is equipped with a sophisticated protection against vandalism mechanism These detectors can sense certain changes to the original their alignment position as set during installation A change of the detector s alignment generates a permanent alarm until the detector s alignment is returned to its original position or until the position is manually reset After the turn on time typically 60 seconds from power on the detector determines and stores its alignment position this will only occur when the detector cover closed After opening and closing the cover w

Download Pdf Manuals