Home

Warranty, Regulatory and Safety Information

image

Contents

1. Unplug the printer before you clean it Use only a damp cloth Do not use liquid or aerosol cleaners Place your printer on a firm solid surface If you put it on something unsteady it may fall and be damaged If you place it on a soft surface such as a rug sofa or cushion the vents may be blocked causing the printer to overheat Protect your printer from overheating Make sure no obstructions block the openings of the printer Do not put the printer on or near a heat source such as a radiator or heat register Keep the printer out of direct sunlight Allow enough room around the printer for adequate ventilation and easy access to the paper trays If you put the printer in any kind of enclosure make sure the enclosure is properly ventilated Do not use your printer near water Do not spill liquid of any kind into it Be certain that your power source matches the rating listed on the back of the printer If you are not sure check with your dealer or with your local power company Your printer has a grounded three prong plug as a safety feature This plug only fits into a grounded outlet If the plug does not fit the outlet may be an older non grounded type Contact an electrician to have the outlet replaced Do not use an adapter to defeat the grounding Install the printer near an easily accessed power outlet Avoid damaging the power cord Do not put anything on it or place it where it will be walked on If the cord be
2. FCC regulations Changes or modifications not expressly approved by Oki Data may void your authority to operate this device Industry Canada IC IC Radio Interference Statements 120 Volt Models This Oki Data apparatus complies with the Class B limits for radio interference as specified in the IC Radio Interference Regulations 230 240 Volt Models This Oki Data apparatus complies with the Class A limits for radio interference as specified in the IC Radio Interference Regulations European Union Council of the European Communities EUCEC EUCEC Statements of Conformance Electromagnetic Conformance This product complies with the requirements of the Council Directive 89 336 EEC on the approximation of the laws of the member states relating to electromagnetic compatibility Safety Conformance This product is in conformity with Directive 73 23 EEC on the harmonization of the laws of Member States relating to electrical equipment designed for use within certain voltage limits Safety Information Your OKI printer has been carefully designed to give you years of safe reliable performance As with all electrical equipment there are a few basic precautions you should take to avoid hurting yourself or damaging the printer Carefully read the provided setup and operating instructions Save all provided documentation for future reference Read and follow all warning and instruction labels on the printer itself
3. Laurel NJ 08054 4620 Tel 856 235 2600 Fax 856 222 5320 my okidata com 14 Oki Data Americas Inc 2000 Bishops Gate Blvd Mt Laurel NJ 08054 4620 Tel 856 235 2600 FAX 856 222 5320 http www okidata ccom my okidata com Oki Data Americas Inc 2735 Matheson Blvd East Unit 1 Mississauga Ontario Canada L4W 4M8 T l 1 800 654 3282 T l c 905 238 4427 Oki Data de Mexico S A de C V Mariano Escobedo No 748 8 Piso Col Anzures e p 11590 Mexico DF Tel 52 55 5263 8780 FAX 52 55 5263 8785 Oki Data do Brasil Ltda Av Leonardo da Vinci 1178 1182 Jabaquara S o Paulo Brasil Tel 5511 3444 3500 FAX 5511 3444 3501 Central de suporte 0800 11 55 77 e mail okidata okidata com br OKI is a registered trademark of Oki Electric Industry Company Ltd marque d pose de Oki Electric Industry Company Ltd marca registrada Oki Electric Industry Company Ltd 2004 Oki Data Americas Inc 59365601
4. by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and the receiver Plug the unit into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio television technician for help Note Itis the responsibility of the user to obtain the required shielded cable in order to ensure compliance of this equipment with FCC regulations Changes or modifications not expressly approved by Oki Data may void your authority to operate this device 230 240 Volt Models This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC rules These limits are designed to provide reasonable protection against harmful interference in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense Note Itis the responsibility of the user to obtain the required shielded cable in order to ensure compliance of this equipment with
5. develop appropriate work practice guidelines and employee instructional programs for your operation Preparation Date of MSDS Date September 1 2004 Prepared by Oki Data Americas Inc Engineering Services Department 2000 Bishops Gate Blvd Mt Laurel NJ 08054 4620 Tel 856 235 2600 Fax 856 222 5320 my okidata com 12 Material Safety Data Sheet MSDS 58355001 for Type C4 Yellow Toner P N 41963001 For more information contact Oki Data at 2000 Bishops Gate Boulevard Mount Laurel NJ 08054 4620 Emergency Information call 1 800 654 3282 US and Canada only Emergency First Aid Procedures __ Toner swallowed ingested Immediately seek medical attention Never give anything by mouth to an unconscious person If possible rinse out mouth and give one or two glasses of water or milk to drink Toner inhaled Remove person to fresh air Seek medical attention Toner gets in the eyes Flush eyes with large quantities of cool water for 15 minutes keeping the eyelids open with fingers If necessary seek medical attention Toner gets on the skin Wash toner off the skin with plenty of cool water and soap If necessary seek medical attention Note Small amounts of toner on skin or clothing can easily be removed with soap and cold water Hot water makes toner harder to remove Hazardous Ingredients Silica dioxide about 2 by weight CAS Confidential OSHA PEL Not established ACGIH TLV Not e
6. if the product has been damaged due to abuse misuse misapplication accident or as a result of service or modification by any other than an authorized Oki Data service center THERE ARE NO EXPRESS WARRANTIES OTHER THAN THOSE ON THE FACE HEREOF AND DESCRIBED ABOVE NO WARRANTIES WHETHER EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE SHALL EXTEND BEYOND THE RESPECTIVE WARRANTY PERIOD DESCRIBED ABOVE Some states do not allow limitations on how long an implied warranty lasts so the above limitation may not apply to you OKI DATA SHALL NOT BE RESPONSIBLE OR LIABLE FOR ANY SPECIAL INCIDENTAL OR CONSEQUENTIAL DAMAGES OR LOSS ARISING FROM THE USE OF THIS PRODUCT Some states do not allow the exclusion or limitation of incidental or consequential damages so the above exclusion may not apply to you Additional information on obtaining service under this Limited Warranty in the U S and Canada is available by contacting the Oki Data dealer from whom the product was purchased by contacting Oki Data directly at 1 800 654 3282 1 800 OKI DATA or by contacting one of the service locations listed below Spanish Only call 1 856 222 7496 Canada Only call 1 905 238 4275 This Limited Warranty applies to this printer However the procedure for obtaining service may vary outside the continental United States Contact your Oki Data dealer for such warranty servic
7. quantities of cool water for 15 minutes keeping the eyelids open with fingers If necessary seek medical attention Toner gets on the skin Wash toner off the skin with plenty of cool water and soap If necessary seek medical attention Note Small amounts of toner on skin or clothing can easily be removed with soap and cold water Hot water makes toner harder to remove Hazardous Ingredients Carbon Black about 4 by weight CAS Confidential OSHA PEL Not established ACGIH TLV Not established LDso Not available LCso Not available Silica dioxide about 2 by weight CASH Confidential OSHA PEL Not established ACGIH TLV Not established LDso Not Available LCso Not Available Physical Data Physical State Solid Melting Freezing Point Not available Boiling Point Not available pH Not available Vapor Pressure Not available Vapor Density Air 1 Not available Evaporation Rate Butyl Acetate 1 Not available Specific Gravity H 0 1 1 1 to 1 2 at 20 C 68 F Solubility in Water Not available Solubility in Solvents Some components are soluble in toluene chloroform and tetrahydrofuran Coefficient of water oil Distribution Not available Appearance and Odor Black powder no odor Odor Threshold Not available Percent Volatile Not available Fire and Explosion Hazard Data Minimal fire hazard Large quantities may cause risk of dust explosion Flash Point Method Used Not
8. 0 compliance Federal Communications Commission FCC FCC Declaration of Conformity 1 Product Identification Product Model Product Model C7350 120 V N31033A C7350 230 V N31033B C7550 120 V N31032A C7550 230 V N31032B 2nd 3rd Tray N31050A 2nd 3rd Tray N31051A 2 Statement This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation 3 Responsible Party Oki Data Americas Inc 2000 Bishops Gate Boulevard Mt Laurel NJ 08054 4620 1 800 654 3282 1 800 OKI DATA FCC Radio Frequency Interference Statements 120 Volt Models WARNING This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined
9. Explosion Data Sensitivity to Mechanical Impact Not available Sensitivity to Static Discharge Not available Extinguishing Media In case of small fire use CO In case of large fire shut off air by spraying with water or foam Special Fire Fighting Procedures Fight fire from upwind position Avoid inhalation of smoke or gases Wear self contained breathing apparatus Hazardous Combustion Products Carbon monoxide oxides of nitrogen Toxicological Properties Routes of Entry Inhalation Ingestion Eyes Skin Effects of Acute Exposure Not available Effects of Chronic Exposure Not available Exposure Limits Not available Irritancy Not available Sensitivity Not available Carcinogenicity IARC Silica Dioxide Group 3 Not classifiable NTP No components are listed OSHA No components are listed Reproductive Toxicity Not available Teratogenicity Not available Mutagenicity Not available Name of Toxicoligically Synergistic Products Not available Reactivity Data Stability Stable in general Conditions to Avoid Avoid excess heat and all sources of ignition Polymerization Will not occur Hazardous Decomposition or Byproducts Combustion products include harmful gases such as carbon monoxide and nitrogen oxides Incompatibility Not available Preventive Measures Personal Protective Equipment Respiratory Protection Not normally required For large spills use dust respirator during clean
10. OKI C7350 and C7550 Warranty Regulatory and Safety Information Limited Warranty U S and Canada Oki Data Americas Inc Oki Data warrants this printer to be free from defects in material and workmanship and will remedy any such defect according to the terms of this Limited Warranty Oki Data will repair or at its option replace at no charge any defective component s of the Printer for one 1 year from the date of purchase except for the printheads LED imaging arrays which are warranted for a period of five 5 years from date of purchase This Limited Warranty extends to the original purchaser only This Limited Warranty does not extend to consumable items On Site Repair Note On Site Repair is available in the United States and Canada only On Site Repair does not include the replacement or repair of product consumables or supplies Oki Data will for a period of one 1 year from the date of original purchase repair or replace at Oki Data s option on site at the original purchaser s facility and without charge any defective component s of the printer provided that the warranty service is performed by an Oki Data authorized service provider The printheads LED imaging arrays have a 5 year parts only warranty from date of original purchase Following the first year of warranty coverage the printheads will be replaced by an authorized Oki Data service provider at Oki Data s then current labor rates Ok
11. applicable Flammable Limits Lower Explosive Limit Not available Upper Explosive Limit Not available Auto Ignition Temperature Not available Explosion Data Sensitivity to Mechanical Impact Not available Sensitivity to Static Discharge Not available Extinguishing Media In case of small fire use CO In case of large fire shut off air by spraying with water or foam Special Fire Fighting Procedures Fight fire from upwind position Avoid inhalation of smoke or gases Wear self contained breathing apparatus Hazardous Combustion Products Carbon monoxide oxides of nitrogen Toxicological Properties Routes of Entry Inhalation Ingestion Eyes Skin Effects of Acute Exposure Not available Effects of Chronic Exposure Not available Exposure Limits Not available Irritancy Not available Sensitivity Not available Carcinogenicity IARC Silica Dioxide Group 3 Not classifiable Carbon Black Group 2B Possible Carcinogen NTP No components are listed OSHA Carbon black is designated hazardous according to OSHA 29 CFR 1910 1200 Reproductive Toxicity Not available Teratogenicity Not available Mutagenicity Not available Name of Toxicoligically Synergistic Products Not available Reactivity Data Stability Stable in general Conditions to Avoid Avoid excess heat and all sources of ignition Polymerization Will not occur Hazardous Decomposition or Byproducts Combustion produ
12. arts and consumable supplies contact us at any time e 1 800 654 3282 1 800 OKI DATA www OKIDATA com Your Own Personal Solutions Center my okidata com Your Personal Solutions Center You can easily create your own Personal Solutions Center providing up to the minute Oki information specifically for your product including e Product news e Manuals e Drivers and utilities e Material Safety Data Sheets e Searchable knowledge base e and much more Just take a few minutes setting it up once then you can check your Personal Solutions Center for the latest information at any time Get started today by visiting http MY OKIDATA com Customer Support Representatives 1 800 654 3282 1 800 OKI DATA Customer Support Representatives are available 24 hours a day 7 days a week Please have the model number and serial number for your machine handy Be sure that you are calling from a telephone close to your machine so you can describe your problem accurately and follow up on the suggestions of the Customer Support Representative right while you are on the phone Our Customer Support Representatives are trained on all current OKI products They can answer your questions regarding e Locations of sales and service dealers e Installation of your machine e Usage normal maintenance of your machine e Error message interpretation solutions e Parts and supplies identification e Consumer relations Note Customer Su
13. comes damaged or frayed replace it immediately If you are using an extension cord or power strip with the printer make sure that the total of the amperes required by all the equipment on the extension is less than the extension s rating The total ratings of all equipment plugged into the outlet should not exceed 15 amperes Do not poke anything into the ventilation slots of the printer You could get an electrical shock or cause hazardous electrical arcing which could cause a fire Aside from the routine maintenance described in the documentation do not try to service the printer yourself Removing the cover may expose you to shocks or other hazards Do not make any adjustments other than those outlined in the documentation You may cause damage that will require extensive repair work The provided documentation explains how to get your printer serviced by qualified Oki Data technicians If anything happens that indicates that your printer is not working properly or has been damaged unplug it immediately and follow the procedures in the provided documentation for having your printer serviced Here are some of the things to look for e The power cord or plug is frayed or damaged e Liquid has been spilled into the printer or the printer has been exposed to water e The printer has been dropped or the cabinet is damaged e The printer does not function normally when you are following the operating instructions Specif
14. cts include harmful gases such as carbon monoxide and nitrogen oxides Incompatibility Not available Preventive Measures Personal Protective Equipment Respiratory Protection Not normally required For large spills use dust respirator during cleanup Protective Gloves and or Eye Protection Not normally required For large spills use rubber gloves and safety goggles during cleanup Engineering Controls Ventilation Outside of normal ventilation not normally required Other Protective Equipment and or Hygienic Practices None Spill Cleanup Small Spills 1 Remove sources of ignition 2 Carefully clean up the spill with a wet cloth avoiding inhalation of fine dust Large Spills 1 Remove sources of ignition and keep unnecessary and unprotected personnel away from area 2 Wear protective gear respirator rubber gloves safety goggles 3 Vacuum the spill then wipe up remainder with a wet cloth Waste Disposal e Prevent release of material into natural waters and sewers e Follow appropriate federal state and local regulations e Small amounts can be incinerated Careful Combustion can create harmful gases such as carbon monoxide and nitrogen oxides e Large amounts must be passed to a licensed waste contractor Precautions Precautions for Handling or Storage Protect from the sun Store in a cool room under 104 F 40 C Keep out of reach of children Other Precautions None Shipping Information Sp
15. e information This warranty gives you specific legal rights and you may also have other rights which vary from state to state Service and Support U S and Canada Oki Data is firmly committed to the satisfaction of our customers If you have a problem that your customer documentation cannot solve contact the listed sources for service or support Oki Data Authorized Service Providers For the most comprehensive up to date listing of Oki Data authorized Service Centers in the United States and Canada In the U S go to www okidata com and click Dealer Locator e In Canada and the U S call 1 800 654 3282 1 800 OKI DATA Oki Data Contact Locations United States Oki Data Americas Inc 2020 Bishops Gate Blvd Canada Oki Data Americas Inc 2735 Matheson Blvd East Mt Laurel NJ 08054 Unit 1 Phone 1 800 654 3282 Mississauga Ontario Fax 1 856 222 5247 Canada L4W 4M8 Phone 1 800 654 3282 Fax 1 905 238 4421 Sales and Service Dealers Consult the store location where you purchased your machine or contact Oki Data for the location of the nearest Authorized Oki Data Service Dealer e Prices and minimum charges may vary e Proof of purchase is required for warranty work Be sure to retain your purchase documents Telephone Support Automated Services for Your Convenience Quick Referrals To get quick referrals for a local Sales and Service Authorized Reseller including products p
16. ecial Shipping Information Non hazardous Handle container carefully to avoid shock Do not drop Keep dry User s Responsibility This bulletin cannot cover all possible situations which the user may experience when using this product Each aspect of your operation must be examined in regard to if or where additional precautions may be necessary All health and safety information contained in this bulletin must be provided to your employees or customers It is your responsibility to use this information to develop appropriate work practice guidelines and employee instructional programs for your operation Preparation Date of MSDS Date September 1 2004 Prepared by Oki Data Americas Inc Engineering Services Department 2000 Bishops Gate Blvd Mt Laurel NJ 08054 4620 Tel 856 235 2600 Fax 856 222 5320 my okidata com Material Safety Data Sheet MSDS 58355201 for Type C4 Cyan Toner P N 41963003 For more information contact Oki Data at 2000 Bishops Gate Boulevard Mount Laurel NJ 08054 4620 Emergency Information call 1 800 654 3282 US and Canada only Emergency First Aid Procedures __ Toner swallowed ingested Immediately seek medical attention Never give anything by mouth to an unconscious person If possible rinse out mouth and give one or two glasses of water or milk to drink Toner inhaled Remove person to fresh air Seek medical attention Toner gets in the eyes Flush eyes with
17. ent and or Hygienic Practices None Spill Cleanup Small Spills 1 Remove sources of ignition 2 Carefully clean up the spill with a wet cloth avoiding inhalation of fine dust Large Spills 1 Remove sources of ignition and keep unnecessary and unprotected personnel away from area 2 Wear protective gear respirator rubber gloves safety goggles 3 Vacuum the spill then wipe up remainder with a wet cloth Waste Disposal e Prevent release of material into natural waters and sewers e Follow appropriate federal state and local regulations e Small amounts can be incinerated Careful Combustion can create harmful gases such as carbon monoxide and nitrogen oxides e Large amounts must be passed to a licensed waste contractor Precautions Precautions for Handling or Storage Protect from the sun Store in a cool room under 104 F 40 C Keep out of reach of children Other Precautions None Shipping Information Special Shipping Information Non hazardous Handle container carefully to avoid shock Do not drop Keep dry User s Responsibility This bulletin cannot cover all possible situations which the user may experience when using this product Each aspect of your operation must be examined in regard to if or where additional precautions may be necessary All health and safety information contained in this bulletin must be provided to your employees or customers It is your responsibility to use this information to
18. ghting Procedures Fight fire from upwind position Avoid inhalation of smoke or gases Wear self contained breathing apparatus Hazardous Combustion Products Carbon monoxide oxides of nitrogen Toxicological Properties Routes of Entry Inhalation Ingestion Eyes Skin Effects of Acute Exposure Not available Effects of Chronic Exposure Not available Exposure Limits Not available Irritancy Not available Sensitivity Not available Carcinogenicity IARC Silica Dioxide Group 3 Not classifiable NTP No components are listed OSHA No components are listed Reproductive Toxicity Not available Teratogenicity Not available Mutagenicity Not available Name of Toxicoligically Synergistic Products Not available Reactivity Data Stability Stable in general Conditions to Avoid Avoid excess heat and all sources of ignition Polymerization Will not occur Hazardous Decomposition or Byproducts Combustion products include harmful gases such as carbon monoxide and nitrogen oxides Incompatibility Not available Preventive Measures Personal Protective Equipment Respiratory Protection Not normally required For large spills use dust respirator during cleanup Protective Gloves and or Eye Protection Not normally required For large spills use rubber gloves and safety goggles during cleanup Engineering Controls Ventilation Outside of normal ventilation not normally required Other Protective Equipm
19. i Data reserves the right to use new and or refurbished parts in the warranty repair process As a condition of this Limited Warranty requests for On Site Repair must include the name and phone number of a fully competent and responsible adult with the authority to consent to the entry of the servicing technician to the premises where the printer is located and who will remain with the servicing technician while the service work is performed Any and all dangerous conditions must be removed from the site prior to and throughout the time a service technician is present The service technician may refrain from entering the premises or continuing to provide services at any site if in the servicing technician s reasonable judgement the site poses a risk of physical harm or danger If warranty services cannot be performed or completed due to any of the foregoing reasons the On Site service option is null and void and the product must be returned to an authorized Oki Data service location for warranty repair service To make request or claim for service under this Limited Warranty contact your local Oki Data authorized service center or Oki Data at 1 800 OKI DATA 1 800 654 3282 A written receipt for the product showing the date of purchase dealer s name and both the model and serial numbers of this printer must accompany any request or claim for work to be performed under this Limited Warranty This Limited Warranty shall not apply
20. ications For additional specifications see the on line User s Guide Electrical Voltage 120 110 to 127 VAC 60 Hz 2Hz 230 220 to 264 VAC 50 Hz 2Hz Power Standby 1200 W max average 150 W Operating 1500 W max average 500 W Power Cord Type 13A shielded Caution Be sure to use the power cord supplied with the printer Use of a power cord not supplied with the product or use of an extension cord may result in overheating and could be a safety hazard Environmental Temperature Operating 50 to 89 6 F 10 to 32 C Max Color Print Quality 62 6 to 80 6 F 17 to 27 C Power Off 32 to 110 F 0 to 43 C Storage packed up 14 to 110 F 10 to 43 C Relative Humidity Operating 20 to 80 RH Max Color Print Quality 50 to 70 RH Power Off 10 to 90 RH Storage packed up 10 to 90 RH Material Safety Data Sheet MSDS 58355301 for Type C4 Black Toner P N 41963004 For more information contact Oki Data at 2000 Bishops Gate Boulevard Mount Laurel NJ 08054 4620 Emergency Information call 1 800 654 3282 US and Canada only Emergency First Aid Procedures __ Toner swallowed ingested Immediately seek medical attention Never give anything by mouth to an unconscious person If possible rinse out mouth and give one or two glasses of water or milk to drink Toner inhaled Remove person to fresh air Seek medical attention Toner gets in the eyes Flush eyes with large
21. l Anzures e p 11590 Mexico DF Phone 52 555 263 8780 Fax 52 555 250 3501 Brazil Oki Data do Brasil Ltda Rua Alexandre Dumas 2220 8 andar Ch cara Santo Antonio S o Paulo Brazil 04717 004 Phone 5511 3444 3500 Fax 5511 3444 3501 Support Center 0800 11 55 77 email okidata O okidata com br Contacting Oki Data If you are having a problem with your OKI printer or need service please contact the store where you bought your OKI product or contact any of the Authorized Service Centers shown for your Country Region on our Web site www okidata com for information e Prices and charges may vary e A copy of the proof of purchase is required for the warranty process Regulatory Information ENERGY STAR As an ENERGY STAR Program Participant ane A the manufacturer has determined that this product meets the ENERGY STAR guidelines for energy efficiency Year 2000 Compliance All products currently sold by Oki Data are Year 2000 Compliant Each product contains information technology that accurately processes date and time data between the years 1999 and 2000 and carries no issue for the September 9 1999 9999 programming concern These products when used in combination with products purchased from other manufacturers whose products properly exchange data and time information will accurately process the date and time All future products are committed to meeting the same Year 200
22. l numbers of the Oki Data Product must accompany any request or claim for work to be performed under this Limited Warranty This Limited Warranty shall not apply if the Product has been damaged due to abuse misuse misapplication accident or as a result of service or modification by any other than an authorized Oki Data service center THERE ARE NO EXPRESS WARRANTIES OTHER THAN THOSE ON THE FACE HEREOF AND DESCRIBED ABOVE NO WARRANTIES EXPRESS OR APPLIED INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE SHALL EXTEND BEYOND THE RESPECTIVE WARRANTY PERIODS NOTED ABOVE OKI DATA SHALL NOT BE RESPONSIBLE OR LIABLE FOR ANY SPECIAL INCIDENTAL OR CONSEQUENTIAL DAMAGES OR LOSS ARISING FROM THE USE OF THIS PRODUCT Service and Support Latin America Oki Data is firmly committed to the satisfaction of our customers If you have a problem that your customer documentation cannot solve contact the listed sources for service or support Oki Data Authorized Service Centers For the most comprehensive up to date listing of Oki Data Authorized Service Centers in Latin America e Consult our web site www okidata com e In Spanish speaking countries contact the Latin America Service Coordinator at Oki Data s Corporate Headquarters at 856 222 5276 Spanish only Oki Data Contact Locations Mexico Oki Data de Mexico S A de C V Mariano Escobedo No 748 8 Piso Co
23. l amounts of toner on skin or clothing can easily be removed with soap and cold water Hot water makes toner harder to remove Hazardous Ingredients Silica dioxide about 2 by weight CAS Confidential OSHA PEL Not established ACGIH TLV Not established LDso Not Available LCso Not Available Physical Data Physical State Solid Melting Freezing Point Not available Boiling Point Not available pH Not available Vapor Pressure Not available Vapor Density Air 1 Not available Evaporation Rate Butyl Acetate 1 Not available Specific Gravity 1 0 1 1 1 to 1 2 at 20 C 68 F Solubility in Water Not available Solubility in Solvents Some components are soluble in toluene chloroform and tetrahydrofuran Coefficient of water oil Distribution Not available Appearance and Odor Magenta powder no odor Odor Threshold Not available Percent Volatile Not available 11 Fire and Explosion Hazard Data Minimal fire hazard Large quantities may cause risk of dust explosion Flash Point Method Used Not applicable Flammable Limits Lower Explosive Limit Not available Upper Explosive Limit Not available Auto Ignition Temperature Not available Explosion Data Sensitivity to Mechanical Impact Not available Sensitivity to Static Discharge Not available Extinguishing Media In case of small fire use CO In case of large fire shut off air by spraying with water or foam Special Fire Fi
24. large quantities of cool water for 15 minutes keeping the eyelids open with fingers If necessary seek medical attention Toner gets on the skin Wash toner off the skin with plenty of cool water and soap If necessary seek medical attention Note Small amounts of toner on skin or clothing can easily be removed with soap and cold water Hot water makes toner harder to remove Hazardous Ingredients Silica dioxide about 2 by weight CAS Confidential OSHA PEL Not established ACGIH TLV Not established LDso Not Available LCso Not Available Physical Data Physical State Solid Melting Freezing Point Not available Boiling Point Not available pH Not available Vapor Pressure Not available Vapor Density Air 1 Not available Evaporation Rate Butyl Acetate 1 Not available Specific Gravity 1 0 1 1 1 to 1 2 at 20 C 68 F Solubility in Water Not available Solubility in Solvents Some components are soluble in toluene chloroform and tetrahydrofuran Coefficient of water oil Distribution Not available Appearance and Odor Cyan powder no odor Odor Threshold Not available Percent Volatile Not available Fire and Explosion Hazard Data Minimal fire hazard Large quantities may cause risk of dust explosion Flash Point Method Used Not applicable Flammable Limits Lower Explosive Limit Not available Upper Explosive Limit Not available Auto Ignition Temperature Not available
25. on Ingestion Eyes Skin Effects of Acute Exposure Not available Effects of Chronic Exposure Not available Exposure Limits Not available Irritancy Not available Sensitivity Not available Carcinogenicity IARC Silica Dioxide Group 3 Not classifiable NTP No components are listed OSHA No components are listed Reproductive Toxicity Not available Teratogenicity Not available Mutagenicity Not available Name of Toxicoligically Synergistic Products Not available Reactivity Data Stability Stable in general Conditions to Avoid Avoid excess heat and all sources of ignition Polymerization Will not occur Hazardous Decomposition or Byproducts Combustion products include harmful gases such as carbon monoxide and nitrogen oxides Incompatibility Not available Preventive Measures Personal Protective Equipment Respiratory Protection Not normally required For large spills use dust respirator during cleanup Protective Gloves and or Eye Protection Not normally required For large spills use rubber gloves and safety goggles during cleanup Engineering Controls Ventilation Outside of normal ventilation not normally required Other Protective Equipment and or Hygienic Practices None Spill Cleanup Small Spills 1 Remove sources of ignition 2 Carefully clean up the spill with a wet cloth avoiding inhalation of fine dust Large Spills 1 Remove sources of ignition and keep unnecessary and unp
26. pport Representatives are not trained to provide assistance with the use of commercial software packages Please consult your software user s manual for times and availability of their support Limited Warranty Latin America Oki Data warrants this printer hereinafter Product to be free in defect in material and workmanship and will remedy any such defect according to the terms of this Limited Warranty This Limited Warranty does not extend to consumable items including but not limited to image drum cartridges toner cartridges fuses etc Consumables are covered separately under individual consumable warranties Please refer to the appropriate consumable item s warranty for further information Oki Data will repair or at its option replace at no charge any defective component s of the Printer for one 1 year from the date of purchase except for the printheads LED imaging arrays which are warranted for a period of five 5 years from date of purchase This Limited Warranty extends to the original purchaser only To make a request or claim for service under this Limited Warranty the original purchaser must return the Oki Data Product to an Authorized Oki Data Service Center within the country purchased The purchaser returning the Product for repair must pay for all transportation charges to the repair center A written receipt for the Product showing the date of purchase dealer s name and both the model and seria
27. rotected personnel away from area 2 Wear protective gear respirator rubber gloves safety goggles 3 Vacuum the spill then wipe up remainder with a wet cloth Waste Disposal e Prevent release of material into natural waters and sewers e Follow appropriate federal state and local regulations e Small amounts can be incinerated Careful Combustion can create harmful gases such as carbon monoxide and nitrogen oxides e Large amounts must be passed to a licensed waste contractor Precautions Precautions for Handling or Storage Protect from the sun Store in a cool room under 104 F 40 C Keep out of reach of children Other Precautions None Shipping Information Special Shipping Information Non hazardous Handle container carefully to avoid shock Do not drop Keep dry User s Responsibility This bulletin cannot cover all possible situations which the user may experience when using this product Each aspect of your operation must be examined in regard to if or where additional precautions may be necessary All health and safety information contained in this bulletin must be provided to your employees or customers It is your responsibility to use this information to develop appropriate work practice guidelines and employee instructional programs for your operation Preparation Date of MSDS Date September 1 2004 Prepared by Oki Data Americas Inc Engineering Services Department 2000 Bishops Gate Blvd Mt
28. stablished LDso Not Available LCso Not Available Physical Data Physical State Solid Melting Freezing Point Not available Boiling Point Not available pH Not available Vapor Pressure Not available Vapor Density Air 1 Not available Evaporation Rate Butyl Acetate 1 Not available Specific Gravity 1 0 1 1 1 to 1 2 at 20 C 68 F Solubility in Water Not available Solubility in Solvents Some components are soluble in toluene chloroform and tetrahydrofuran Coefficient of water oil Distribution Not available Appearance and Odor Yellow powder no odor Odor Threshold Not available Percent Volatile Not available 13 Fire and Explosion Hazard Data Minimal fire hazard Large quantities may cause risk of dust explosion Flash Point Method Used Not applicable Flammable Limits Lower Explosive Limit Not available Upper Explosive Limit Not available Auto Ignition Temperature Not available Explosion Data Sensitivity to Mechanical Impact Not available Sensitivity to Static Discharge Not available Extinguishing Media In case of small fire use CO In case of large fire shut off air by spraying with water or foam Special Fire Fighting Procedures Fight fire from upwind position Avoid inhalation of smoke or gases Wear self contained breathing apparatus Hazardous Combustion Products Carbon monoxide oxides of nitrogen Toxicological Properties Routes of Entry Inhalati
29. tion must be examined in regard to if or where additional precautions may be necessary All health and safety information contained in this bulletin must be provided to your employees or customers It is your responsibility to use this information to develop appropriate work practice guidelines and employee instructional programs for your operation Preparation Date of MSDS Date September 1 2004 Prepared by Oki Data Americas Inc Engineering Services Department 2000 Bishops Gate Blvd Mt Laurel NJ 08054 4620 Tel 856 235 2600 Fax 856 222 5320 my okidata com 10 Material Safety Data Sheet MSDS 58355101 for Type C4 Magenta Toner P N 41963002 For more information contact Oki Data at 2000 Bishops Gate Boulevard Mount Laurel NJ 08054 4620 Emergency Information call 1 800 654 3282 US and Canada only Emergency First Aid Procedures __ Toner swallowed ingested Immediately seek medical attention Never give anything by mouth to an unconscious person If possible rinse out mouth and give one or two glasses of water or milk to drink Toner inhaled Remove person to fresh air Seek medical attention Toner gets in the eyes Flush eyes with large quantities of cool water for 15 minutes keeping the eyelids open with fingers If necessary seek medical attention Toner gets on the skin Wash toner off the skin with plenty of cool water and soap If necessary seek medical attention Note Smal
30. up Protective Gloves and or Eye Protection Not normally required For large spills use rubber gloves and safety goggles during cleanup Engineering Controls Ventilation Outside of normal ventilation not normally required Other Protective Equipment and or Hygienic Practices None Spill Cleanup Small Spills 1 Remove sources of ignition 2 Carefully clean up the spill with a wet cloth avoiding inhalation of fine dust Large Spills 1 Remove sources of ignition and keep unnecessary and unprotected personnel away from area 2 Wear protective gear respirator rubber gloves safety goggles 3 Vacuum the spill then wipe up remainder with a wet cloth Waste Disposal e Prevent release of material into natural waters and sewers e Follow appropriate federal state and local regulations e Small amounts can be incinerated Careful Combustion can create harmful gases such as carbon monoxide and nitrogen oxides e Large amounts must be passed to a licensed waste contractor Precautions Precautions for Handling or Storage Protect from the sun Store in a cool room under 104 F 40 C Keep out of reach of children Other Precautions None Shipping Information Special Shipping Information Non hazardous Handle container carefully to avoid shock Do not drop Keep dry User s Responsibility This bulletin cannot cover all possible situations which the user may experience when using this product Each aspect of your opera