Home
User Manual DTS-12C Standalone Scrambler
Contents
1. current limiting resistance 1 MQ Floor bearing should be greater than 450Kg m Environment Under 5 40 C operate for long time under 0 45 C operate for short temperature time installing air conditioning is recommended Relative Under 20 80 operate for long time under10 90 operate for short temperature time 86 105KPa Installing rubber strip for sealing door gaps and dual level glasses for Door amp window window be covered with wallpaper or brightness less paint rather than easy Wall pulverization dope Fire protection Have Fire alarm system and extinguisher Requiring device power air conditioning power and lighting power are Power independent to each other Device power requires AC power 220V 50Hz 50W Please carefully check before running 2 2 3 Grounding requirement m All function modules good grounding designs are the base of reliability and stability of device Also they are the most important guarantee of lightning arresting and interference rejection Therefore system must follow this rule m Coaxial cable s outer conductor and isolation layer should keep sound electric conducting with the metal housing of device Page 6 DTS 12A User Manual m Grounding conductor must adopt copper conductor in order to reduce high frequency impedance and the grounding wire must be as thick and short as possible m The 2 terminals of grounding wire must make sure for well electric conducting and proce
2. BO EEE tend an DTS 12C Standalone Scrambler User Manual DTS 12A User Manual _ tend an Chapter 1 Product Outline 1 1 Outline DTS 12A stand alone scrambler is applied in the simultcrypt scrambling of input code stream It can send fixed or agile word scrambling according to transport stream The built in simulcrypt synchronization controller transmits the exchange information with ECMG When integrated with CA the scrambler adjusts crypto period appropriately in order to make decoder function normally This is a highly integrated equipment for digital TV scramble 1 2 Features DVB common scramble system description ETR289 common scramble system description DVB Scramble designated program or transport stream Comply with DVB standard arithmetic supports simultcrypt compatible with multi CA system Comprehensive MPEG code stream analysis Re process PSI SI information from TS Channel protection for ASI output Bit rate auto adaption PCR reset and re mark Remote real time monitor of transport stream Auto switch and input backup pocket format auto adaption of 188 204 bit rate Network monitor PCR correction 1 3 Application Program collect distribute Page 1 DTS 12A User Manual SDH network transport satellite DVB T MMDS Digital CATV Front head end Video on demand VOD Digital swerve Video distribution for television network Program encrypt Transport stream disposal Origina
3. al wire The signal connection wires are both ASI 2 4 1 ASI input connection User can find ASI IN1 IN8 input port on the Equipment according to connector mark described in the rear panel illustration and then connecting the Q9 coaxial cable one end to the ASI IN1 8 and the other end to the Encoder s or other equipment ASI output port 2 4 2 ASI Output Port Connection User can find ASI output port on the Equipment according to connector mark described in the rear panel illustration and then connecting the ASI cable in the accessories one end to the JKDH 6102 multiplexer s ASI output port and the other end to the scrambler s or Modulator s input port multiplexer s ASI output port and its connected ASI cable connector illustrated as follow Page 8 DTS 12A User Manual Chapter 3 Operation DTS 12C Stand alone scrambler s front panel is user operation interface before operation we should collocate input output parameters Input parameter setting including program option output parameter setting including realtive setting of transport stream the device can be use directly based on the setted default parameters user also can opt the programs accordingly The display supply specific menu for option Steps as follow Keyboard Function Shift UP DOWN LEFT RIGHT button Turn over cursor set up parameter edit ENTER Store the ending from modified parameter and execute the opted function Modify the activat
4. eck packed goods according to packing list or below items e DTS 12C Stand Alone Scrambler e User manual e Coaxial line with Q9 head for each ends e AC input power cord If there is any missing or mismatch of above items please contact local dealer 2 2 Installation preparation Follow below steps when installing the device The detailed installation will be described at the rest part of this chapter the back panel illustration is for concrete positation reference Following content is the main for this chapter 1 unit lcopy 1 radix 1 radix Checking if there any possible missing or damage device during transport Checking if the situation is suitable for installing Install Stand Alone Scrambler Connecting signal wires Connecting communication port for option 2 2 1 Installation flow per below chart Acquisition Check Fixing Device Connecting Grouding Wire and Power Cord gt Connecting Signal Wire Setting Parameter Running Device Page 5 DTS 12A User Manual 2 2 2 Environment Requirement When user install machines array in one machine hall the Machine hall distance between 2 row of machine frames should be 1 2 1 5m space and the distance to wall should be no less than 0 8m Electric Isolation Dust Free Machine hall Volume resistivity of ground anti static material 1x10 1x10 o floor Grounding
5. ed parameter and turn over LOCK Lock Menu Store Display current situation MENU Cancel 3 1 Homepage Normal Working Condition Stand Alone Scrambler Efficient TS 00 012Mbps 3 2 Press LOCK into Main Menu 1 Input Info 2 Output Setting 3 Network Setting Press UP DOWN to select 4 Saving Config 5 Loading Config 6 Version 7 Language Page 9 DTS 12A User Manual 3 3 Input Information After user select this setting system display as below 1 1 Program 05 Program 1 CCTV1 1 1 Program 05 Program 2 CCTV2 1 1 Program 05 Program 3 CCTV3 1 1 Program 05 Program 4 CCTV4 1 1 Program 05 Program 5 CCTVS5 3 4 Output setting After user select this the system display as below 2 1 Output stream 34 000 Mbps User can finish the setting of Transport stream 3 5 Network Setting After user select this setting the system display as below Page 10 DTS 12A User Manual 3 1 Address 101 101 101 138 3 2 Subnet mask 255 255 255 000 3 3 Gateway 10110110100 3 4 Console Address 101 101 101 211 User can finish the network setting D a 3 7 Saving Config After user select this setting press Enter to save directly the system will display as below Saving Please wait 3 8 Loading Config The system will display as below after enter this setting 5 1 Load Saved CFG 5 2 Load Default CFG 3 9 Version Enter the menu of Version the interface disp
6. l front head end of Center Page 2 DTS 12A User Manual 1 3 Technical Parameter Dimension 44mm 482mm 410mm 0 45 C Operating 20 80 C storage Power supply 220VAC 10 50Hz 25W Miscellaneous Temperature 1 4 Principle Frame Ethernet interface module TS Input TAT module Keyboard 1 5 Appearance and description Front panel illustration StandAlone Scrambler Digital Power O eB A Enter Menu Lock video O a NI gP E O ontsa Lock O nOr V 3 1 2 a 3 6 T g 9 10 Il Page 3 DTS 12A User Manual 1 LCD Screen display 2 Power indicator green 3 Signal lock indicator 4 ECMGI signal indicator 5 EMMG signal indicator 6 EMMG2z signal indicator 7 ECMG 2 signal indicator 8 Up down left right button 9 Confirm button 10 Cancel button 11 Menu button lock button Back panel illustration O sour 1 2 O hernet O 10m O 100M to 2 3 4 j ASI TS output interface 1 ASI TS output interface 2 ASI TS input interface 1 ASI TS input interface 2 Ethernet interface Power on off Fuse Power socket Oo 1 O IN Aa M A wo JN Grounding Page DTS 12A User Manual 2 1 Acquisition check Open the device package and check the articles do check the packing material of samll Charter2 Installation Guide parts ch
7. lay as below Page 11 DTS 12A User Manual 3 10 Language Chinese and English Enter it and select the language according to the UP DOWN button there will be an asterisk before the selected language for confirm The selected language with added asterisk is the current language the default language is Chinese as below English HANS After complete all the setting the system work normal Page 12
8. ss for antirust m Itis prohibited that users use other devices as part of grounding wire s electric circuit m The section of the conjunction between grounding wire and device s frame should be equal or greater than 25 mm 2 2 4 Frame Grounding All the machine frames should connect to protective copper strip The grounding wire should be as short as possible and avoid circling The section of the conjunction between grounding wire and grounding strip should be equal or greater than 25mm 2 2 5 Device Grounding Connecting the device s grounding rod to frame s grounding strip with copper wire 2 3 Wire s Connection The power supply outlet is located at the left of rear panel and the power switch is just above it The protective grounding wire connective screw is located at the down left side of power supply outlet e Connecting Power Cord User can insert one end into power supply outlet while insert the other end to AC power e Connecting Grounding Wire When the device solely connects to protective ground it should adopt independent way say share the same ground with other devices When the device adopts united way the grounding resistance should be smaller than 1Q Caution Before connecting power cord to Encoder user should set the power switch to OFF Page 7 DTS 12A User Manual 2 4 Signal Wire Connection The signal connections include the connection of input signal wire and the output sign
Download Pdf Manuals
Related Search
Related Contents
Manual de instrucciones Iron 6 Sanyo VCC-MC600P User's Manual Acme United NI-51 Ford 2007 F-150 Automobile User Manual Programme Bretagne Aquatic Science à projet: [a DGCS fait [e point Elo Touch Solution 22CM2 Copyright © All rights reserved.
Failed to retrieve file