Home
PDF spec sheet - Pathfinder Instruments
Contents
1. Portable High Pressure Pneumatic Calibrators PC10 Series Features e High accuracy 0 025 FS e Generates pneumatic pressures to 3000 psi e Dual channel readout pressure and electrical e Self contained rechargeable gas cylinder e RS 232 interface and documenting versions e Coarse fine adjust selection CE The PC10 Series of high pressure pneumatic calibrators are the latest additions to a comprehensive range of com pact and rugged instruments This range of portable calibrators is designed to make testing and calibration of high pressure instruments and systems both quick and simple These self contained portable calibrators from SI Pressure provide unparalleled accuracy and control performance A built in gas cylinder provides source pressures up to 3000 psi a precision pressure regulator and fine volume adjuster ensures optimum control and a digitally characterized sensor measures pressure to better than 0 025 of full scale Field and workshop operation The PC10 pressure cali brators are designed for use in the workshop on the plant or out in the field The large capacity gas cylinder ensures maximum productivity between refills In addition the cali brators can be operated directly from an external pressure source connected to the charging port Dual channel display The PC10 are dual channel instruments able to display both the input and output values simultaneously The calibrators are capable of providin
2. 68 F Built in Nitrogen Air cylinder max refill pressure 3000psi Storage volume 122 cubic inches Capacity 14 0 cubic feet Oxygen Free Nitrogen OFN Please consult factory for list Electrical Input Ranges 50VDC 55mA 15 to 105 F Open Close Switch Temperature coefficient 0 004 reading F w r t 68 F Input Accuracy 0 05 Rdg 0 004 FS 2 F Resolution 100 microV max 0 001mA 0 1 F Output Ranges 10VDC 24VDC 0 24mA Temperature coefficient 0 004 reading F w r t 68 F Output Accuracy 0 1 for 10VDC 5 for 24VDC Maximum Load Display Other Specifications 0 05 Rdg 0 01 FS 10mA for 10VDC 26mA for 24VDC Dual display can simultaneously monitor mA V switch continuity and ambient temperature Also 10VDC and 24VDC power supplies are available for the Device Under Test Pressure Units mA Source Process Functions Power Management Display Data Storage Documenting Features 25 Scale units plus one user defined Auto10 sec step cycle and programmable 60 sec end to end ramp Filter max min tare flow and span Auto power OFF auto backlight OFF battery Status indicator 2 36 x 2 36 inches graphic LCD with backlight 99999 readout 2 reading per second 92 kb memory 1 Calibration mode showing on line error analysis indicating Pass Fail status 2 Storage of As Found and As Left results 3 Graphical analysis of results showing Pass Fail tolerance 4 Two way PC inte
3. 200 200 bar 3 000 psi Box B Type G Gauge A Absolute Box C Documenting S Standard D Fully Documenting Box D Options N NIST Calibration Certificate TTI Inc 8 Leroy Road P O Box 1073 Williston VT 05495 800 235 8367 802 863 0085 802 863 1193 Fax E mail sales ttiglobal com www ttiglobal com
4. g current and voltage excitation to the unit under test UUT and can measure d c voltage d c current and ambient tem perature Electrical terminations are made by industry stan dard 4mm sockets and the large backlit display provides a clear readout of the process parameters Application specific Task Menu A dedicated task key provides instant access to the task menu permitting the cali brator to be configured for specific applications for example the P I task configures the calibrator to source pressure and measure current 24Vdc loop power is also available to allow complete pressure transmitter calibration Running the pres sure switch task captures the open and closed switch values and calculates switch hysteresis The contact resistance of the switch under test can also be monitored Reduce process downtime The PC10 enables calibra tion criteria to be easily entered via the keypad allowing fast diagnosis of field instruments and automatic reporting of errors with a Pass or Fail status i PC10 Series Specifications Pressure Pressure Ranges Accuracy Maximum Overpressure Pressure Reference Temperature Effects Pressure Source Recommended Media Remote Pressure Sensors 39 bar 500 psi 70 bar 1000 psi 100 bar 1500 psi 140 bar 2000 psi 200 bar 3000 psi Combined non linearity hysteresis amp repeatability 0 025 FS 2X FS Gauge or absolute 0 002 of rdg F averaged and w r t
5. rface for transferring test procedures and results Specifications may change without notice Environmental Temperature Operating range 15 to 120 F Calibrated 15 to 105 F Humidity 0 to 90 non condensing Sealing Nema 12 IP54 Conformity EN61010 EN61326 Class A CE marked Physical 28 Ibs dimensions approx 16 9 x 10 x 6 5 in Power Supply Battery powered 6 x 1 5 V NiCad cells 20 hrs nominal use at 68 F The unit will operate from AC power supply and allow the battery pack to recharge Display indicates a low battery condition Options Remote Pressure Sensors Mating Cable for Remote Sensor Accessories The calibrators have a second pressure channel which can be configured with up to 10 remote sensors one at a time The sensors are sup plied with an electrical connector and 1 4 NPT female pressure ports Mating cable is required A 6 foot mating cable for connecting remote sensors to the calibrator At least 1 should be ordered when ordering remote pressure sensor Delivery Ordering Information The PC10 Series is supplied with a battery charger test leads RS 232 cable user manual pressure test certificate calibration certificate and accessory bag as standard Please note The Nitrogen cylinder will be supplied empty for filling on site PC10 AJAJA B C 3 Box A Pressure Range 035 35 bar 500 psi 070 70 bar 1 000 psi 100 100 bar 1 500 psi 140 140 bar 2 000 psi