Home
User Manual - SmartThings Support
Contents
1. WWA 02AA to your DISTRIBUTOR for an exchange or for a full refund within 30 days of purchase Or you can return the WWA 02AA to FORTREZZ with an RGA number All products to be returned to FORTREZZ LLC must have a valid Returned Goods Authorization RGA Send the returned unit to FortrezZ LLC Warranty Replacement 1080 Centre Rd Suite C Auburn Hills Hills MI 48462 postage prepaid with a payment of US 9 95 to cover the cost of return shipping postage and handling You must use the original packaging and include a proof of purchase photocopy of receipt along with the RGA and the returned Wireless Water and Freeze Alarm 1080 Centre Rd Suite C Phone 248 481 7092 N Auburn Hills MI 48326 sales fortrezz com FORTREZ www fortrezz com Made in USA 060212 TECHNICAL APPENDIX MANUFACTURER ID 0x0084 PRODUCT ID varies PRODUCT TYPE ID 0x0063 US 0x0061 EU DEVICE CLASS Generic Type Sensor MultiLevel Specific Type Routing Sensor Multilevel COMMAND CLASSES SUPPORTED in addition to COMMAND_CLASS_BASIC COMMAND_CLASS_ALARM_V2 COMMAND_CLASS_BATTERY COMMAND_CLASS_WAKE_UP_V2 COMMAND_CLASS_MANUFACTURER_SPECIFIC COMMAND_CLASS_CONFIGURATION COMMAND_CLASS_SENSOR_MULTILEVEL COMMAND_CLASS_ ASSOCIATION COMMAND_CLASS_VERSION WATER ALARM Sampling every 4 seconds Z Wave transmissions every approx 30 minutes while alarm is active Basic Set with Value OxFF sent to associated nodes in Group 1 and or Group 2 and or
2. cause harmful interference and 2 This device must accept any interference received including interference that may cause undesired operation From section 5 2 RSS Gen Issue 2 June 2007 Equipment Labels Contains IC 8156A Z3X From section 7 1 1 RSS Gen Issue 2 June 2007 a The host device as a stand alone unit without any separately certified modules complies with all applicable Radio Standards Specifications b The host device and all the separately certified modules it contains jointly meet the RF exposure compliance requirements of RSS 102AA if applicable c The host device complies with the certification labeling requirements of each of the modules it contains Eu rope The WWA 02AA module has been certified for use in European countries Test standard ETSI EN 300 328 V1 7 1 2006 10 The Waste Electrical and Electronic Equipment WEEE directive 2002AA 96 EC was approved by the European Parliament and the Council of the European Union in 2003 This symbol indicates that this product contains electrical and electronic equipment that may include batteries printed circuit boards liquid crystal displays or other components that may be subject to local disposal regulations at your location Please understand these regulations and dispose of this product in a responsible manner Limited Warranty THE PRODUCT IS PROVIDED WITH ONE YEAR LIMITED MANUFACTURER WARRANTY FORTREZZ LLC warrants its products to be free from def
3. EZ www fortrezz com Made in USA when the switch is pressed and held for 2 seconds In either case the WWA 02AA will stay awake for approximately 30 seconds after this to allow time for configuration commands from the controller Refer to Status indications below for LED feedback Wakeup Notification The WWA 02AA will wakeup and send a notification every 4 hours default to allow a controller to query and update the status of the unit A brief switch press while in network will also cause the WWA 02AA to wakeup and send a notification The device stays awake for 5 seconds during this time or longer if communicating with the controller Status LED Indications Number of Blinks Meaning Fast Blinks Normal Operation 1 Wakeup Notification Sent after quick switch press while in Network 2 Water Alarm 3 Temperature Alarm either high or low setpoint triggered 4 An active alarm has been cleared when a water alarm or a temperature alarm is no longer active 5 Low Battery repeated every approx 40 seconds Slow Blinks After Battery Replacement or Inclusion Exclusion 1 In Network also after button held while in Network 3 Out of Network also given if inclusion was not completed If the LED remains continually on after inserting a battery please remove the battery and contact FortrezZ LLC customer service Choosing a mounting location The WWA O2AA is suitable for use in dry interior location
4. WWA 02AA Wireless Water amp Freeze yA a Temperature Alarm User Manual Peik EN work together better Thank you for purchasing this Wireless Water amp Freeze Temperature Alarm This product will provide you with peace of mind and the protection you expect Leaking pipes corroded water heaters fixtures in bathrooms and laundry rooms refrigerator drip pans etc can all cause water damage The WWA 02AA is a Z Wave enabled device that will send a water alert on your Z Wave network Devices performing other functions and from other manufacturers can also be part of your Z Wave network and can act as repeaters to extend your network range Functionality The WWA 02AA alarms when water is detected and will also provide a Z Wave alarm signal when the temperature drops below a low temperature setpoint or rises above a high temperature setpoint The WWA 02AA functionality is based on wireless RF transmissions Any wireless transmission can be subject to RF interference and although unlikely this interference may cause the unit to not operate as intended The WWA 02AA must not be used in life support and or safety applications Information provided in this manual is for your convenience and may be superseded by updates The specifications and this manual are subject to change without notice It is your responsibility to ensure that the WWA 02AA meets your specifications Specifications Power Two AA alkaline batteries B
5. an Alarm Command Class V2 Water Leak Report Event Water Leak Detected Unknown Location 0x02AA with Alarm Level OxFF What is sent depends on whether associations are configured and or Water Leak Alarm is enabled with a non zero destination Node ID see Alarm Factory Default State under OTHER below Visual indication of water alarm via LED Alarm Command Class V2 Get Sensor Type 0x05 Water Leak can be used to request water alarm state When water alarm is no longer active sends Basic Set with Value 0x00 to association nodes as above and or Alarm Command Class Water Leak Report Unknown Event OxFE with Alarm Level 0x00 UNDER TEMPERATURE OVER TEMPERATURE ALARM Sampling every 4 seconds with averaging algorithm Sensor has an accuracy of approx 2 degC Default alarm trigger points set at approx 4 degC and 70 degC Z Wave transmissions every approx 30 minutes while alarm is active Basic Set with Value OxFF sent to associated nodes in Group 1 and or Group 3 and or Alarm Command Class V2 Heat Report with Alarm Level OxFF and Event Overheat Detected unknown location 0x02AA or Underheat Detected unknown location 0x06 What is sent depends on whether associations are configured and or Heat Alarm is enabled with a non zero destination Node ID see Alarm Factory Default State under OTHER below Visual Indication of temperature alarm via LED Alarm Command Class V2 Get Sensor Type 0x04 Heat
6. attery Life Calculated to be 1 to 2 years with no alarms and default Z Wave network settings Frequency Range 908 4MHz US 868 4MHz EU Distance Range Max 100ft line of sight in unobstructed environment Size LxWxD and Weight 3 76 mm x 2 1 53mm x 1 1 30mm Product Weight 0 24 Ib 109 g Operating Temperature 10 C 14F to 70 C 158F Reported Temperature Reported temperature is at the unit and has a 2 degC accuracy System Requirement Any Z Wave enabled network and controller Using the WWA 02AA ina Z Wave Network Program Switch for Inclusion or Exclusion The switch is used for including or excluding the WWA 02AA in a Z Wave network Water amp Temperature Sensor Refer to your controller s User Manual for specific details on network inclusion exclusion and association Inclusion in adding to a network 1 Set up the inclusion mode at the controller 2 Briefly press the switch once and the controller will indicate the unit has been included in the network Also the LED will blink when the inclusion completes nclusion and exclusion are always done at normal transmit power mode Exclusion from removing from a network 1 Set up the exclusion mode at the controller 2 Press and hold the switch for approx 2 seconds until the controller indicates the unit has been removed from the network The LED will blink when the exclusion completes Associations Once in a network a controller can be
7. ble for compliance could void he user s authority to operate the equipment FCC Interference Statement Part 15 105 b This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help Industry Canada Statement per Section 4 0 of RSP 100 The term IC before the certification registration number only signifies that the Industry Canada technical specifications were met Section 7 1 5 of RSS GEN Operation is subject to the following two conditions 1 This device may not
8. can be used to request heat alarm state When temperature alarm is no longer active sends Basic Set with Value 0x00 to association nodes as above and or sends Alarm Command Class Heat Report Unknown Event OxFE with Alarm Level 0x00 BATTERY STATUS Battery level percentage estimated based on number of Wakeup1 s see below since battery insertion In addition battery voltage readings can trip the low battery state Low battery report Battery Command Class every approx 30 minutes after low battery becomes active Visual indication of low battery every approx 40 seconds WAKEUPS Wakeup1 Power saving design wakes up every 4 seconds to test water and freeze sensor Wakeup2 Once every approx 4 hours default unit wakes up to send a notification either to a wakeup node or broadcast The unit stays awake for approx 5 seconds or while communicating with a controller Sensors are not checked during this time The Wakeup node is the node configured to receive the Wakeup Notification command This is set in the WWA 02AA by the Wakeup Interval Set command and is typically the Controller node Only one value for the wakeup interval the default interval of 0x003840 4 hours can be set MULTILEVEL SENSOR Multilevel Sensor Report sent with current Temperature Degrees C in response to Multilevel Sensor Get command Unsolicited Multilevel Sensor Report sent to Wakeup Node within 30 minutes of a 1 degree temperature change if Wak
9. ects in material and workmanship under normal use for one year and is not responsible for consequential damages or installation costs of any nature FORTREZZ LLC expressly disclaims all implied warranties including but not limited to the implied warranties of merchantability and fitness for a particular purpose FORTREZZ LLC does not warrant guarantee or make any representations regarding the use or the results of the use of the products or any accompanying materials in terms of their correctness accuracy reliability or otherwise In no event shall FORTREZZ LLC be liable to Purchaser hereunder or in respect of any products ordered or delivered to Purchaser whether in contract tort including negligence or otherwise for a loss of profits or loss of use or for any incidental consequential special or indirect damages howsoever caused whether or not FORTREZZ LLC has been advised of the possibility of such loss or damage FORTREZZ LLC s maximum liability to Purchaser under these conditions shall in no event exceed the amount paid by Purchaser for the products that are the subject of the claim and in respect of all claims for products ordered from FORTREZZ LLC to which these conditions apply to the amount paid by Purchaser for the products which are the subject of the claims If you are not comfortable with your limited warranty or not completely satisfied with the WWA 02AA or the WWA 02AA does not perform as expected we encourage you to return the
10. epending on your specific controller s capabilities you will be able to remotely check the status of any WWA 02AA in your network Testing the WWA 02AA Moisten a paper towel and place over both of the small metal pads on the water sensor until you observe two quick LED blinks The water alarm indication may take up to 4 or 5 seconds If the LED fails to blink your battery may be old or dead or incorrectly installed the sensor may not be moist enough or the water sensor may be damaged If you see the LED blink remove the moistened paper towel and clean the small metal pads of any water residue and the LED should blink four times You can then add the WWA 02AA to your Z Wave network using your controller Examples of Z Wave controllers can be found on the FortrezZ website www fortrezz com Battery Low Battery The WWA O2AA will send an alert on the Z Wave network at regular intervals when it detects a low battery condition In addition it will periodically blink the LED Your controller may be able to be configured to monitor the unit s wake up notifications If these stop then this might also be an indication that the battery has died or that transmissions from the WWA O2AA are no longer being received After a water leak please ensure that there is no moisture in the unit and around the battery Do not install batteries that appear damaged or unsealed When replacing batteries the water seal may be broken around the screws After scr
11. eup node is set filtering is applied to avoid oscillating report transmissions and conserve battery life transmission is independent of a Wakeup Notification CONFIGURATION Parameter 1 sets Low Temperature Trigger Point degrees Centigrade 1 signed byte Default 4 Parameter 2 sets High Temperature Trigger Point degrees Centigrade 1 signed byte Default 70 KEEP ALIVE Switch activated causes 30 sec RF receiver on time intended for Controller configuration after network inclusion Sensors not checked during Keep Alive time OTHER Alarm Factory default state Enabled unsolicited alarm reports underheat overheat and water leak will be sent to Node 0x01 after inclusion This Node ID can be changed via the Alarm Set Command Alarm Command Class V2 All Network Inclusions Exclusions are at normal power levels Up to 5 nodes allowed in each association group Basic Report sent in response to a Basic Get with value equal to Multilevel Sensor Type Temperature 0x01 Built with Z Wave SDK 4 51 S 1080 Centre Rd Suite C Phone 248 481 7092 E Auburn Hills MI 48326 sales fortrezz com FORTREZ www fortrezz com Made in USA 060212
12. ewing the parts back together the use of some sealant such as silicone caulk around the screws is recommended Configuring the WWA 02AA The high and low temperature setpoints in the WWA 02AA can be configured The low temperature setpoint must always be set at least two degrees below the high temperature setpoint The low temperature setpoint cannot be set less than 10 degrees C and the 1080 Centre Rd Suite C Phone 248 481 7092 N Auburn Hills MI 48326 sales fortrezz com FORTREZ www fortrezz com Made in USA 060212 high temperature setpoint cannot be set greater than 70 degrees C The temperature setpoints can be configured via a smart controller after inclusion details are provided in the technical appendix Temperature Reports If your controller sends the wakeup interval set command the controller will also become the Wakeup Master node The WWA 02AA will automatically send temperature reports to this Wakeup Master node within a half hour of a 1 degree C change in temperature FCC Compliance Statement Statements This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 This device must accept any interference received including interference that may cause undesired operation Contains Transmitter Module FCC ID XCT Z3US FCC Warning Part 15 21 Changes or modifications not expressly approved by the party responsi
13. s only Avoid placing the unit close to a metal frame or other metal enclosures that may affect RF range Place the unit so that any leaks that may occur will not drip directly on the unit Recommended WWA O2AA uses Under sink Next to Sump pumps Water Heaters Laundry Room Bathroom Floor Storage Area Garage Utility Sink Vacation Recreation homes Boats etc During an alarm If water is detected at the monitoring location or an over under temperature conditions is detected the unit will send an alert message s to the Z Wave network if included in the network The type of alert message depends on how the WWA O02AA is configured If associations are configured Basic Set messages will be sent as described above under Associations If Water or Heat Alarms have been configured via Alarm Command Class V2 Set commands then the WWA 02AA will send alert messages to the Node ID that configured the alarm Association alert messages and Alarm alert messages may both be configured and sent Drying the sensor contacts will clear the Water Alarm If an over under temperature Alarm occurred and the temperature alarm conditions are no longer present an alarm clear message is also sent to the Z Wave network if included in the network Also depending on your Z Wave controller it is possible to receive a remote alert For example with some gateway controllers you can receive an email or cell phone text message when an alarm is activated D
14. used to associate the WWA 02AA with other devices in the Z Wave network such as a light or another remote audible alarm Refer to your controller s documentation on how to associate WWA 02AA with another device in your network The WWA 02AA supports three association groups with a maximum of 5 devices in each group Basic Set commands are sent at 30 minute intervals to the associated groups while alarms are active A Basic Set Command is sent to the associated nodes if any assigned to Group1 to indicate that EITHER a Water Alarm OR Heat Alarm under or over temperature is active A Basic Set Command with value OxFF is sent to the associated nodes if any assigned to Group2 to indicate that a Water Alarm is active When the water alarm is cleared by drying the contacts one additional report with value 0x00 is sent A Basic Set Command is sent to the associated nodes if any assigned to Group3 to indicate that a Temperature Alarm over or under temperature is active When the temperature alarm is cleared due to temperature change one additional report with value 0x00 is sent Node Info Keep Alive While not in a network the WWA 02AA will send the Z Wave Node information frame when the switch is briefly pressed This is primarily used for inclusion as described above The node information frame will also be sent while in network S 1080 Centre Rd Suite C Phone 248 481 7092 N Auburn Hills MI 48326 sales fortrezz com FORTR
Download Pdf Manuals
Related Search
Related Contents
Blueair ECO10 User's Manual Horno Microondas Con Convección con Sensor MANUEL D`INSTRUCTIONS & PIÈCES Tutorial de usuario - Inicio 原子力災害対応ガイドブック. PR-01DAB - Migros FB Library Start-up Guide Copyright © All rights reserved.
Failed to retrieve file