Home
Installation & User Manual N-24 round N-21 flat
Contents
1. Sintef product documentation for N 21 Norges branntekniske laboratorium as NBL 7465 Trondheim SINTEF PRODUKTDOKUMENTASJON SINTEF 041 135 FOR LUFTFORURENSNING OG BRANNTEKNISK SIKKERHET Med henvisning til Plan og bygningsloven revidert 1997 06 13 med Teknisk forskrift og tilh rende Veiledning av 1997 01 22 bekrefter Norges branntekniske laboratorium as med grunnlag i pr vingsrapporter og vurderinger at angitt produkt im tekommer norske myndigheters krav til begrenset luftforurensning og brannteknisk sikkerhet S ker og produktansvarlig Nordpeis as Gjellebekkstubben 9 11 3420 Lierskogen Produsent Spartherm D 49305 Melle Tyskland Produktnavn Nordpeis N21 Produkttype Peisinnsats Rentbrennende lukket ildsted for omramming Beskrivelse Ildsted av st lplater med r khette av st pejern brennkammer isolert med Vermiculite i bunn side og hvelv Enkel d r med stort vindu D rh ndtak m betjenes med varmebeskyttende hanske R kuttak topp horisontal eller vertikal r kf ring 150 mm Bruksomr de Brensel ved av lengde 5 35 cm Oppstillingsavstand mot forskriftsmessig brannmur med omramming av ubrennbare materialer 2 20 mm fra utvendig skjermplate Avstand topp omramming til brennbart tak gt 300 mm Omramming m ventileres med pning 500 em ved bunn og gt 750 cm ved topp Brennbart gulv m dekkes med metall eller ubrennbar plate under og foran ildsted Hele gulvflaten innenfor omramming s
2. Use kindling or firelighters to light the fire Open the Lighting draft control fig 1 Keep the door ajar until the chimney is warmed Add larger logs until the fire is established Once established the lighting draft control should be closed Use this vent only for the first 15 min utes after lighting the fire if used for longer the insert may become overheated The air supply should now be adjusted by using the upper draft control fig 2 Add additional logs when required The flames should be burning lively and blue flames indicate an optimal and pure combustion 7 Maintenance Make sure the fire insert is cold before commencing any maintenance The glass door If the glass becomes sooted use either a stove glass cleaner and a soft cloth and wipe clean or sim ply dip a damp soft cloth into the wood ashes and rub this over the glass and then use a clean cloth to buff the glass Only clean the glass when it is cold Check the glass screws regularly to ensure they have not loosened The screws should gently grip the glass they should not be tight as this does not allow enough expansion and can then break the glass The door and glass gaskets should be replaced annually to ensure they serve there purpose correctly Ashes should be removed regularly we recommend that a thin layer of ash is kept at the bottom of the insert to assist with burning Please note that wood ashes can remain hot even the day after the fire has been l
3. House owners name Address Postal code City Installers name Address Postal code City Fireplace model and manufacturer Energy efficiency Fuel type Chimney type e g brick steel prefabricated Cross section Number of fire area cm places on same chimney Controllers name Address Postal code City Qualifications Checked by craftsman during installation Checkpoint Yes No Is fireplace installed according to the manual LJ E Is minimum distance to firewall checked LI Is minimum distance to flammable materials checked E E Is minimum distance to ceiling checked E E Is there a non flammable plate under and in front of fireplace E E Will the floor withstand the weight of the fireplace LI E Do the chimneysweeper have access to soot hatch and smoke pipe J E Do the inset have access to enough combustive air through air vents into the room E LI Is smoke inlet into chimney mounted as recommended by chimney manufacturer LJ Is the chimney suited for this fireplace LI E Do the chimney have an adequate gross section area E E Are there access to product documents and installation manuals on the construction site E roes GE EEE er City Date Craftsman s signature CONTROL DECLARATION Installation is checked by the use of Supplemented checklist J J Visual control J J Video camera J J ME Installation is checked and approved VET 0 en City Date Controllers signature It is a benefit to have documentation of correct installation in existence Hav
4. Nordpeis Installation amp User Manual 24 round 21 flat Fire Inset appliance from Nordpeis AS Congratulations on purchasing a new fireplace insert from Nordpeis Your fireplace insert has been tested and documented by the National Fire Laboratory of Norway SINTEF to assure it s safety and environmental compliance SINTEF test requirements are amongst the strictest in the world to contribute to a safer and healthier environment The purpose of this manual is to provide guidance on how to operate your new appliance safely and efficiently we can not stress the importance of reading this manual before using your appliance enough It is your responsibility to ensure that the wood you intend to burn on this appliance is well seasoned a minimum of 2 years old with a moisture content of no more than 20 this will enable your fire place insert to operate efficiently Nordpeis have over 30 years of experience in developing and manufacturing stoves and fireplace inserts We only introduce our products to the marketplace after several years of research and testing on our combustion techniques have taken place We thank you for chosing a Nordpeis product and hope it will give you many years of warmth and comfort in the future Best regards Nordpeis AS Mn part Stian Varre Managing Director TABLE OF CONTENTS IMPORTANT INFORMATION 4 1 Before installation 5 2 Technical data N 21 6 3 Technical data N 24 7 4 Ins
5. e this form filled in and contain it as security for the residence The homeowner landlord have an obligation to inform the local authorities on the installation of a new fireplace You may also want to send a copy of this form to the local fire dept 19 Nordpeis AS Gjellebekkstubben 9 11 3420 Lierskogen NORWAY Telefon 32 24 47 00 Telefax 32 24 47 08 E post post nordpeis no O po D Q O Le O
6. ed when fire is burning White smoke The combustive temperature is too low Increase air supply to the fire The fire wood is too moist Use only dry and pure fire wood Black or dark smoke Incomplete combustion Increase air supply to the fire 17 10 Appendix Sintef product documentation for N 24 Norges branntekniske laboratorium as NBL 7465 Trondheim SINTEF PRODUKTDOKUMENTASJON SINTEF 041 134 FOR LUFTFORURENSNING OG BRANNTEKNISK SIKKERHET Med henvisning til Plan og bygningsloven revidert 1997 06 13 med Teknisk forskrift og tilh rende Veiledning av 1997 01 22 bekrefter Norges branntekniske laboratorium s med grunnlag i pr vingsrapporter og vurderinger t angitt produkt im tekommer norske myndigheters krav til begrenset luftforurensning og brannteknisk sikkerhet mang a Nordpeis as Gjellebekkstubben 9 11 3420 Lierskogen Produsent Spartherm Feuerungstechnik GmbH D 49305 Melle Tyskland Produktnavn Nordpeis N24 Produkttype Peisinnsats Rentbrennende lukket ildsted for omramming Beskrivelse Ildsted av st lplater med r khette av st pejern brennkammer isolert med Vermiculite i bunn side og hvelv Enkel d r med stort buet vindu D rh ndtak m betjenes med varmebeskyttende hanske R kuttak topp horisontal eller vertikal r kf ring 160 mm Brensel ved av lengde 40 cm Oppstillingsavstand mot forskriftsmessig brannmur med omramming av ubrennbare mater
7. ers Outside 157 Inside 0150 337 888 N QA gt I po u Na I lt a Min 224 __ Max 330 me Important It the fire insert is to be placed on a combustible floor the floor must first be covered with a minimum 0 7 mm thick steel plate 3 Technical data N 24 Firing Door and doorframe finish Black paint chrome faint chrome anthracite paint silver paint golden faint golden Effect SRW Draught control system Lighting draught control and firing draught control Combustion system After burning system pure combustion House heating area Up to 150 m Weigm f Smoke outlets Top rear and both sides Warning If the requirement for sufficient air inlets and air outlet is not maintained it will cause poor air circulation and reduced heating effect In worst case this can cause a conflagration All measures are given in millimeters Outside 157 Inside 150 858 Max 330 me Important It the fire insert is to be placed on a combustible floor the floor must first be covered with a minimum 0 7 mm thick steel plate 4 Installation site Make sure not to under exceed any safety distances The fireplace should be sited with the appliance door no less than 1 meter away from combustial materials Whe
8. ialer 20 mm fra utvendig skjermplate Avstand topp omramming til brennbart tak gt 300 mm Omramming m ventileres med pning gt 500 cm ved bunn og 2 750 em ved topp Brennbart gulv m dekkes med metall eller ubrennbar plate under og foran ildsted Hele gulvflaten innenfor omramming skal dekkes og eventuelt gulvbelegg fjernes Rapport 102040 64 sikkerhet og 102040 64 B milj av 2003 10 17 fra Norges branntekniske laboratorium as Tegningsunderlag Vedlegg til pr vingsrapport av NB blir fu ee med kopi av dette ee skal f lge ildstedet og tl enhver tid v re tilgjengelig for mont r bruker og kontrollerende myndighet feier Produktet skal merkes med SINTEF 041 134 ogs med produktnavn modell produsent produksjonsinformasjon sporbarhet og produktansvarlig Merkingen skal v re lett synlig Produktdokumentasjonens gyldighet er betinget av at det opprettes avtale om tilvirk ningskontroll med NBL eller annet inspeksjonsorgan som NBL aksepterer Kontrollen skal sikre produktets samsvar med vurderingsgrunnlaget Inntil videre men ikke lenger enn til 2008 11 04 Fornyelse utstedes p grunnlag av skriftlig s knad Oppsigelse ved innehaver skal v re skriftlig og med 6 mnd varsel NBL kan tilbakekalle en produktdokumentasjon ved misligheter eller misbruk n r skriftlig p legg om endring ikke blir tatt til f lge Trondheim 2003 11 04 Svein Borel in Sr Svein Baade yvin Brandt avd sjef forsker
9. it so be careful when disposing of the ashes The vermiculite panels in your fire insert ensure a high combustion temperature which in turn provide a more energy efficient fireplace Once the vermiculite panels have reduced to 15mm half their origi nal thickness they must be replaced Important Be careful when removing ash using an ash spade especially for the vermiculite plates 8 Warranty 1 All appliances are supplied under a guarantee against material and manufacturing errors The guarantee is limited to a maximum of the supply of a replacement component and only applies if the instructions for installation and use enclosed with the appliance have been followed and if the product is being used under normal conditions in the dealer s assessment 2 There is a five year guarantee with effect from the date of purchase on cast iron fireplace inserts 3 The guarantee lapses if changes have been made to the appliance without the advance knowledge and written permission of dealer importer and when an appliance has been shipped without sound packaging and transport protection 4 The following are not covered by the guarantee Defects caused by inexpert assembly and or treatment such as overfiring or inncorrect fuel use Costs of transport assembly and dismantling Glass vermiculite panels baffle plates and ceramick fiber gaskets 5 In view of the tremendous variations in the possible options for building a chimne
10. justing screws 1 large clamp strap with 2 adjusting screws 1 heat shield for the back of inset 1 heat shield with self drilling screws for smoke dome 1 heat shield for the combustion air vent 1 cartridge with furnace cement 1 fire inset with door and vermiculite heat insulation plates inside 1 loose grip for air regulator handle A B C D E F G H I J K L IMPORTANT Be careful when touching the fire insert during it s first firings as the paint will be very soft until it has cured It can take several firings to cure the paint 2 Carefully place the inset on it s back and start assembling the legs this way e Fasten adjustment screws to the legs you might want to give the screw a stroke with the hammer to get in place as shown in figure 3a The nut should be fixed into the hexagonal hole e Fasten the legs to the body by using the accompanying screws figure 3b The leg must surround the supporting bracket under the inset as shown in figure 3c The vertical opening in the legs should point towards the centre e Adjust the length of the legs to fit the concrete frame Working range of legs Figure4 From To For N 21 224 mm 330 mm For N 24 240 mm 330 mm 3 Now raise the inset back into upright position do not tilt but lift the insert back into upright position 4 Mounting the smoke dome Mounting lower half of smoke dome e When placed on the inset turn the lower half of the dome
11. k of 33cm is installed 54cm for installations with flue draft stabilisers The fireplace should stand on a fireproof hearth suitably constructed from materials which are able to support the weight of the appliance and the flue system The hearth needs to be 300mm to the front of the appliance and 150mm to each side of the fireplace and must conform to current Building Regu lations You must ensure that the hearth can not be inadvertently be covered by carpet rugs etc this can be done by adding a kerb etc The following clearances around the fireplace must be observed to allow the correct operating proce dure 75mm either side of the fireplace 200mm above the fireplace to non combustible material 380mm above the fireplace to combustible material We have on page 19 placed a check form you can use to prove correct installation of your new fire place 2 Technical data N 21 Dr 7 SSC sS Door and doorframe finish Black paint chrome faint chrome anthracite paint silver paint golden faint golden Fu 717 BOM ete 7 7 SSS Draught control system Lighting draught contol and fring draught control Draught control system Wei T Smoke outlets Top rear and both sides Warning If the requirement for sufficient air inlets and air outlet is not maintained it will cause poor air circulation and reduced heating effect In worst case this can cause a conflagration All measures are given in millimet
12. kal dekkes og eventuelt gulvbelegg fjernes Vurderingsgrunnlag Rapport 10204051 A sikkerhet og 10204051 B milj av 2003 02 19 fra Norges branntekniske laboratorium as Tegningsunderlag Vedlegg til previngsrapport Pr vingsresultater i r ed a r u L blir ful grup med kopi av dete kne taal f lge ildstedet og il enhver tid v re tilgjengelig for mont r bruker og kontrollerende myndighet feier Merking Produktet skal merkes med SINTEF 041 135 ogs med produktnavn modell produsent produksjonsinformasjon sporbarhet og produktansvarlig Merkingen skal v re lett synlig Tilvirknings kontroll Produktdokumentasjonens gyldighet er betinget av at det opprettes avtale om tilvirk ningskontroll med NBL eller annet inspeksjonsorgan som NBL aksepterer Kontrollen skal sikre produktets samsvar med vurderingsgrunnlaget Gyldighetstid Inntil videre men ikke lenger enn til 2008 05 06 Fornyelse utstedes p grunnlag av skriftlig s knad Oppsigelse ved innehaver skal v re skriftlig og med 6 mnd varsel NBL kan tilbakekalle en produktdokumentasjon ved misligheter eller misbruk n r skriftlig p legg om endring ikke blir tatt til f lge Trondheim 2003 05 06 CA vy 3 on at Svein yvin Brandt avd sjef forsker Report form W Nordpeis CHECKLIST AND CONFIRMATION ON VERIFICATION OF FIREPLACE INNSTALLATION Residence address Land number Title number Phone
13. ly pure fire wood YF 16 Hints and tips on problems with the fireplace Problem Cause Repair suggestion Not enough Chimney is choked Clean out smoke pipe and inset If this does not help draught call your chimneysweeper or local dealer for further Smoke pipe is soothed and or there is soot accumu lation on the baffle plate s Misplaced baffle plate s help Smoke ooze out of inset when in use and or when making a fire Lack of fresh air supply to the room where the fireplace is located Open a door or window when making the fire Under pressure in the room electric kitchen vent or air condition evacuates too much air from the room where the fireplace is located Turn of electric vents air condition Smoke pipes from two different fireplaces are con nected to the same chimney at the same level Move one smoke pipe to another level Level difference between two smoke inlets into same chimney should be no less than 30 cm Smoke pipe is elevated downwards into chimney Smoke pipe must be relocated so there is a gradient of at least 10 degree s Alternatively install an electric draught fan with stepless speed control in the chimney Smoke pipe is mounted to far into chimney Smoke pipe must be remounted Must be terminated minimum 5 mm from inner pipe in chimney Soot hatch in basement is open causing false draught into chimney Soot hatches are to be closed at all times A leaky o
14. n the event of skin coming into contact with the fire cement wash off immediately with clean water 1 Before installation Make sure the chimney is in good working order and that the required chimney draft of between 14 25 Pascal negative is obtained A minimum chimney height of 4meters is required The chimney must be Class I suitable for use with wood Please ensure the chimney is swept prior to installing the appliance The chimney is the key to successful installation and operation of the appliance If the chimney is in poor condition or of the wrong design or construction the performance will be adversely effected and problems will be experienced with combustion and possible smoke emission into the room The chimney should be one of the following types e Brick built with suitable liner for use with wood solid fuel appliances e Twin wall stainless steel approved for use with both wood solid fuel appliances Prefabricated concrete type systems approved for use with wood sold fuel appliances DO NOT USE FLEXIBLE LINERS DESIGNED FOR USE ONLY WITH GAS APPLIANCES NEVER ALLOW THE APPLIANCE TO CARRY THE WEIGHT OF THE CHIMNEY You must ensure that there is sufficient fresh air supply within the room as per Building Regulations If insufficient fresh air is provided this will lower the atmospheric pressure within the room and may lead to poor combustion and smoke leakage from the appliance We recommend that a minimum airbric
15. n mounting steel chimney on top of the fireplace we refer to the assembly manual from the respective chimney manufacturer Comply with the safety distances that are required when mounting a steel chimney The fireplace insert model and the concrete surrounding determines height on firewall The distance between smoke pipe and flammable wall amp construction must be at least 300 mm The shortest dis tance between upper air outlets or top of concrete surrounding must be at least 380 mm Placed in corner Placed on straight wall p 20 Firewall rim mounted on wall corner Firewall rim monted on wall straight wall Minimum Minimum firewall width firewall width 575 750 Firewall flush mounted corner Firewall flush mounted straight wall Minimum Minimum firewall width firewall width 760 820 All measures are approximately as misalignment in wall and floor and distance to centre of smoke inlet into chimney can vary 5 Assembling N 21 N 24 The following tools are necessary e 13 mm spanner e Drill screwdriver for crosshead screws e Caulking gun e Possibly a hammer 1 First you should run an inventory on all loose parts and it should contain the following parts look at figure 1 N 21 and figure 2 N 24 3 legs and 3 adjusting screws with set nut Glove and lighter comes with the insert 3 screws with discs 1 smoke dome part 1 1 smoke dome part 2 1 small clamp strap with 2 ad
16. nimal air pollution That is why they use less fire wood to produce the same amount of heating as older fire places and also produce less ash Insets from Nordpeis perform an after burning of the flue gas The combustive process is executed in two steps First there is a conventional fire in the fire wood Then there is a secondary combustion when preheated extreme hot air mixes with the flue gases from the first combustion and a new pure combustion takes place When burning 1 kilo dry fire wood approximately 0 2 kilos disappear as steam 0 6 kilo disappear as flue gases and 0 2 kilo is left behind as charcoal Those 0 6 kilo of flue gases contain only half of the theoretical energy in the fire wood The other half is bound in the charcoal To achieve an optimal combustion the temperature in the inset must be 600 800 C The best way to achieve this is to put less fire wood on the fire more often If one put too much fire wood on the fire the amount of air is insufficient to provide a fire of high enough temperature and the flue gases will disappear uncombusted throughout the chimney This is why it is important to provide the fire with more air after new fire wood is put to the fire to en sure a flash over in the flue gases Use smaller split wood instead of larger This gives a more effective and a cleaner combustive Only pure fire wood is approved as fuel for fire insets from Nordpeis Burning garbage harms the environment amp Use on
17. nt parts that are ready fixed in the inset upon delivery If you need to replace vermiculite please contact your dealer Disassembling of the vermiculite plates is done in reverse order according to figure 11a or 11b Assembling order for inset N 21 figure 11a Assembling order for inset N 24 figure 11b Upper baffle plate flange turned upwards Front moulding Bottom plate Right side plate Left side plate Left corner plate Right corner plate Back plate with logo Lower baffle plate with metal air duct Upper baffle plate flange turned upwards Front moulding Bottom plate Right side plate Left side plate Left corner plate Right corner plate Back plate with logo Lower baffle plate with metal air duct oS 0 YS OONOOARWDN When replacing the upper baffle plate part one the steel profile must be transferred to the new vermiculite plate before mounting When replacing the lower baffle plate the metal air duct must be transferred to the new vermiculite plate Function testing When the inset is assembled an put in place but before pasting up the concrete surroundings one should test these functions Lighting draught control Firing draught control lower right side Top centre Handle turned down closed N21 Handle turned out open N24 Handle turned left open Inner position closed Left position closed Outer position open Right position open Using the in
18. r damaged soot hatch should be replaced Draught controls or doors on fireplaces not in use are open causing false draught into chimney Close doors and draught controls on fireplaces not in use Holes in chimney or open smoke inlets after removed fireplaces causing false draught into chimney Holes and fire inlets no longer in use should be bricked up sealed Defect and leaky brickwork causing false draught into chimney Brick up seal off and render all cracks and leaks Too large cross section area inside chimney gives little or no draught at all Chimney should be renovated Alternatively install an electric draught fan with stepless speed control in the chimney Too narrow cross section area inside chimney caus ing to little smoke evacuation capacity Change to a smaller inset or build a new larger chim ney Alternatively install an electric draught fan with stepless speed control in the chimney Too short chimney causing little or no draught at all Increase height of chimney Smoke ooze out of inset when windy outside Chimney is on a level to low compared to surround ing terrain buildings threes etc Increase height of chimney Alternatively install an electric draught fan with stepless speed control in the chimney Turbulence around chimney due to flat roof Increase height of chimney Alternatively install a chimney cowl Little heat from the fireplace The airflow through
19. rst case this can cause a chimney fire Never operate this appliance with both aircontrols wide open for long periods of time Once the fire is established you should only ever have the one air control open That way one will avoid damage to welded joints and annealing of the steel If you burn the appliance with both air controls open for long periods the insert will quickly overheat which may cause the heat insulation to crack and may cause permanent damage to the insert which is not covered by the warranty Warning The inset must not be overheated This can cause permanent damage to the inset The warranty will not cower such damage Useful information about firing and fireplaces Heating and air distribution We separate between radiation heat and convection heat Convection heat arises in the airspace be tween the inset and the concrete surroundings Cold air is sucked in through the lower air inlet vents in the surrounding This air is heated by the inset and due to the expanding of the air it raises and blows out of the upper air outlets in the concrete surrounding This hot air circulation result in a well distrib uted heat in the house Optimal location of a fireplace is close to centre of the house Radiation heat is the heat one can feel coming through the glass when standing in front of a fireplace Afterburner secondary combustion Modern fire insets are optimized to be extreme energy efficient and at the same time cause mi
20. set as an open fireplace How to remove the door 1 Remove the shipping stop clip on upper door hinge and dispose it Open the door and carefully tighten the little hexagonal socket cap screw right above lower door hinge on the inside of the door figure 12 2 Take a grip on the door close to the body lift the door up and pull the lower hinge free of the body Lower the door and it is disconnected figure 13 Note This fire inset is tested and approved to be a pure combustive energy efficient fireplace It has a narrower and therefore more environmentally friendly smoke dome It requires a strong draft in the chimney to be used as an open fireplace with the door unhooked or wide open 6 Using the fireplace for the first time With your fireplace now installed you can light it for the first time Before you do so please remember The vermiculite panels which line the inside of your fire insert are fragile and can be broken if logs are thrown into the fire insert The vermiculite panels are not covered by the warranty so please be careful when adding wood to your fire During the first few firings the paint will cure Ensure that the room is well ventilated during this period since the paint will give off fumes and a hazy smoke Lighting draft control Upper draft control Warning Never fire up the inset to red hot temperatures This might damage the metal construction Close the upper draught control if this happens
21. tallation site 8 5 Assembling N 21 N 24 9 Vermiculite 12 Function testing 12 Using the inset as an open fireplace 13 6 Using the fireplace for the first time 13 7 Maintenance 14 8 Warranty 14 9 Operating advice 15 Lighting the appliance 15 Recommended fuels 15 Prohibited fuels 15 Useful information about firing and fireplaces 16 Afterburner secondary combustion 16 Hints and tips on problems with the fireplace 17 10 Appendix 18 Sintef product documentation for N 24 18 Sintef product documentation for N 21 18 Report form 19 Last updated 12 09 2007 IMPORTANT INFORMATION This appliance must be installed in line with current building regulations either by a registered installer or in conjunction with your local Building Inspector If in doubt please consult your stockist or local planning office If installed incorrectly this appliance could contribute towards serious accidents and or damage to your property and could invalidate your warranty The manufacturer s responsibility is limited to the supply of this appliance We recommend that a fireguard is used in the presence of children and old infirm people for safety The installer should comply with Health amp Safety regulations Adequate facilities should be provided for handling the appliance Extra care should be taken to avoid accidents and breakage of the glass panels Care should be taken to avoid fire cement contacting the skin The material is caustic and i
22. the Lighting draft control figure 1 page 13 Keep the door ajar until the chimney is warmed Add larger logs until the fire is established Once established the lighting draft control should be closed Use this vent only for the first 15 minutes after lighting the fire if used for longer the insert may become overheated The air supply should now be adjusted by using the upper draft control figure 2 page 13 Add additional logs when required Recommended fuels Dry seasoned hardwood This should be a minimum of 2 years old and have a moisture content no higher than 20 Prohibited fuels Any solid fuel this appliance is suitable for woodburning only Warning Never use treated fuels like gasoline petrol paraffin alcohol or similar to start the fire This can harm both you and the fire inset Paper newspapers leave much ash behind and cartons for milk juice and so one are not suited for starting a fire Warning Do not use impregnated wood painted wood plastic laminated wood plywood fibre plates milk cartons or any other garbage as fuel The warranty is not valid when such materials is used because they can produce harmful flue gas and acid when combusted It is important to use pure and dry fire wood Moist fire wood will produce a lot of soot and steam be cause much of the energy released in the combustion is used to evaporate water and the temperature never gets high enough to getting a pure combustion In wo
23. the inset is too big due to air leaks down in the inset or too much draught from the chimney Difficulties with regulating the combustion and the fire wood burn away at no time Possible leaks must be sealed Too much draught from chimney can come under control buy mounting a damper on the smoke pipe Too much draught Misplaced baffle plates Check baffle plates consult this manual Using super dried fire wood in stead of common fire wood Reduce the fire draught Ceramic gaskets are worn down or flattened Should be replaced with new ones The chimney is too big Call your chimneysweeper or local dealer for further help Glass in inset becomes sooty Wet fire wood Fire wood should contain maximum 20 moist Firing draught control not opened enough Open firing draught control Glass in inset becomes white Poor combustion too low temperature in the inset Consult this manual for correct use and correct firing The use of improper fuel like painted wood plastic laminated wood plywood fibre plates milk cartons Use only dry and pure fire wood Smoke ooze out of inset when its door is opened There is a decompression in the inset Open the door carefully at first only a centimetre or two then wait a few seconds before opening Door is opened when the fire is burning More fire wood should be put on the fire when there is only live coal left Door should not be open
24. to its correct position angle towards the chimney e Use the large clamp strap to fix the dome half and tighten the adjusting screws with the spanner Figure 6b Mounting upper half of smoke dome e Put furnace cement on the part connecting to the upper dome figure 7 e When placed on the lower half of the dome turn the upper half of the dome to its correct position angle towards the chimney figure 7a Use the smaller clamp strap to fix the dome half figure 7b and tighten the adjusting screws with the spanner Figure 7c b 63 6 Mounting heat shield for smoke dome Fix the shield two halves around the smoke dome so the smoke outlet goes through the out cut in the heat shield figure 8 Use the self drilling screws to fix the two halves together 7 Put the heat shield for the combustion air vent loose in place over the air inlets figure 9 7 Installing the flue pipe Figure 10 Q 7 Use150 mm diameter flue pipe to connect the flue pipe into the smoke dome as per figure 10 It is strongly recommended to first stack the concrete surroundings and fire inset without pasting it up to measure out the correct position of the smoke inlet before making a hole into the chimney IMPORTANT Due to the expansion of the inset when heating up the concrete surrounding must not rest on the inset Minimum distance between inset and surroundings are 2 mm Vermiculite The vermiculite consists of 9 differe
25. y we are unable to give any guarantee regarding the draught of a chimney that might lead to complaints about smoke The chimney must be built by a professional and this establishes the guarantee for the proper functioning of this appliance 6 The dealer importer will supply a new component free of charge for every component that be comes defective during the guarantee period The dealer must return the defective compo nent to the importer if requested by the importer stating date of purchase type of appliance and serial number T Renewal or replacement of components that fall under the guarantee cannot prolong the total length of the guarantee The guarantee provides no right whatsoever to indemnification in the event it is not possible to use the fire 8 Liability can never be accepted for loss in any form whatsoever sustained by the customer third parties or their property and caused directly or indirectly by the product 9 Complaints will only be dealt with if the customer has met all his obligations including his obligation to pay Insets from Nordpeis AS comes with five years warranty The dealer who sold the inset handles a pos sible claim in the warranty period 14 9 Operating advice Lighting the appliance During the first few firings the paint will cure Ensure that the room is well ventilated during this period since the paint will give off fumes and a hazy smoke Use kindling or firelighters to light the fire Open