1. e Attach the power cord buckle e Wrap the power cord using the power cord buckle e Clean the main unit drain bucket and air filter as detailed above e Cover the unit with the original plastic bag that came with the unit or any ap propriate dust cover e Store the unit upright in a dry well ventilated place 14 TIPS ON WHEN TO USE YOUR PORTABLE DEHUMIDIFIER If you have respiratory problems asthma and allergies your Whynter Portable Dehumidifier is a great option for controlling moist environments Creating dry air can keep indoor air pollutants at a more manageable level espe cially when used in conjunction with an air purifier Using your portable dehumidifier can help you save money in the long run because it uses relatively little power and can help furnaces and air conditioners operate more efficiently 1 Excess moisture Indoor environments with excessive moisture can cause mold and fungus to thrive inside the walls and be neath the carpet Many types of mold are potentially dangerous and can lead to health problems This Whynter Portable Dehumidifier reduces the amount of moisture in the air inside a home which makes it far more difficult for harmful mold to grow This portable dehumidifier is also effective for a small area such as a hallway or bedroom 2 Respiratory problems or allergies This Whynter Portable Dehumidifier which is perfect for larger rooms or areas in your home including a liv ing room or fam
2. Gu WHYNTER ELITE D SERIES ENERGY STAR 70 PINT PORTABLE DEHUMIDIFIER WITH PUMP Model RPD 711DWP INSTRUCTION MANUAL ENERGY STAR DISPOSAL INFORMATION Thank you for choosing the Whynter Portable Dehumidifier Please follow the instructions provided in this user guide to obtain the very best performance from your dehumidifier We trust that your Whynter dehumidifier will provide the performance and reliability that we stand for Your Whynter dehumidifier is designed to remove moisture in the air by con densation removal and collecting the condensation water in the drain bucket or draining through a drain hose Please keep this user manual in a safe place for future reference This symbol on the product or its packaging indicates that the appliance can not be treated as normal domestic trash but must be handed in at a collection point for recycling electric and electronic appliances Your contribution to the correct disposal of this product protects the environment Further information about the recycling of this product can be obtained from your local municipal authority PAGE DISPOSAL INFORMATION 2 SAFETY PRECAUTIONS 4 INTRODUCTION TECHNICAL DATA 5 PARTS AND CONTROLS 6 9 OPERATION INSTRUCTIONS 10 11 WATER DRAINAGE INSTRUCTIONS 12 13 MAINTENANCE 14 TIPS ON WHEN TO USE YOUR PORTABLE DEHUMIDIFIER 15 TROUBLESHOOTING 16 17 WARRANTY INFORMATION 18 SAFETY PRECAUTIONS TO REDUCE THE RISK OF FIRE
3. ELECTRICAL SHOCK OR INJURY WARNING WHEN USING YOUR PORTABLE DEHUMIDIFIER FOLLOW THESE BASIC PRECAUTIONS e Read all instructions before using the appliance e Never clean appliance parts with flammable fluids The fumes can create a fire hazard Do not use an exces sively wet cloth industrial solvents and oil based products to clean this appliance e Do not store or use gasoline or any other flammable vapors and liquids in the vicinity of this or any other appli ance The fumes can create a fire hazard e Do not abuse sit on or stand on the appliance e This appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction con cerning use of the appliance by a person responsible for their safety e Children should be supervised to ensure that they do not play with the appliance e lf the power cord is damaged it must be replaced by the manufacturer or its service agent or a similarly quali fied person in order to avoid a hazard e Please dispose of packing materials properly e Use the portable dehumidifier only for its intended function This appliance is designed for household non commercial use only Any other use will void the warranty e To avoid the risk of shock the product should never be used in bathrooms shower rooms or in any other steamy or wet areas e During instal
4. Energy Saver When the unit is running on normal operation once the RH is reached the fan will still run continuously to avoid high start up amperage which makes the unit energy efficient Please note that the fan may run continuously or shut off intermittently depending on the RH and set humidity PARTS AND CONTROLS Bucket Full Indicator The appliance will run continuously until the set RH is reached or when the drain bucket is full When the drain bucket is full the Full indicator light will illuminate and the dehumidifier will stop operating Remove the water in the bucket with two hands then place the drain bucket back to it s proper position and the machine will start operating again Auto Defrost Indicator In the event frost builds up on the evaporator coils the compressor will cycle off and the fan will continue to run until the frost is evaporated This happens when the appliance is operating in low temperatures less than 53 F or 12 C which affects the efficiency of the dehumidifier When this happens the Auto Defrost light will turn on and the ma chine will go into periodic defrost mode automatically Defrost time may vary If the dehumidifier freezes up turn the appliance off for few hours and then restart The appliance will not operate satisfactorily if the room temperature is below 41 F Display The display screen shows a number of different indications depending on the selection function e Shows the set relat
5. If you want to remove more moisture set the unit on Continuous operation Empty drain bucket and insert the bucket to the appliance properly Close all windows or doors You may need an additional dehumidifier for area Clean the air filter The appliance must be placed in a space that does not restrict air flowing into the rear coil or out of the front grille Set the RH level and the appliance will stop when the set RH is reached Set the humidity level to a lower RH We recommend setting the RH to at least 10 lower than the current RH Ensure there is at least 10 of clearance for proper ventilation The appliance will not operate satisfacto rily if the room temperature is below 41 F Close windows or doors This is normal due to refrigerant rushing through the coil Frost will usually disap pear within 60 minutes This happens when the appliance is operating in low temperatures less than 53 F The appliance will not operate satisfacto rily if the room temperature is below 41 F Shut off the appliance and let it sit on lev el surface for at least 6 hours TROUBLESHOOTING Many common portable dehumidifiers problems are easily resolved Try the troubleshooting suggestions below to see if the problems can be resolved before having to contact the service department The dehumidifier leaks The dehumidifier does not operate The pump indicator light blinks Water on floor Continuous gra
6. the continuous gravity drain outlet and the plastic cover is installed 2 Insert the 16 ft pump drain hose included into the bottom pump drain outlet See Fig 8 then lead the drain hose to a suitable drain age facility Make sure that the hose is fully inserted to avoid water leakage and no kinks which will cause the water to stop flowing 3 Press the Pump button to activate the pump operation NOTE The water pump will ONLY engage when the drain bucket is full 4 The water pump may make some noise when it starts to work with Pump Drain in the first 3 5 minutes This is a part of the unit s normal operation Outlet Pump Drain 5 Select the desired humidity setting and fan speed on the unit Hose NOTE The Pump Indicator Light will flash when there is a failure in the pump operation Please turn off the unit and unplug the power cord and check the following points e Clean the pump filter remove the drain bucket from the unit pull down Bi the pump filter and clean See Fig 9 Bic Check the pump drain hose for kinks or obstructions Feo e Reinstall the pump filter and drain bucket properly Turn on the unit If the error repeats call for service e Do not use this operation when the outdoor temperature is equal to or less than 32 F Otherwise water hose may be blocked as the water will turn to ice and cause the unit to fail When the pump drain feature is not being used remove the pump drain hose from the
7. 2 hours before first use e When positioning or moving the appliance ensure that it is not turned upside down or greater than 45 or more off level e This appliance must be installed in an area protected from the element such as wind rain water spray or drips e Always place the appliance on even and hard and level surface that can support the unit when it is full of wa ter e Ensure objects are not obstructing the exhaust and air intake e Never insert your fingers or other objects into the air intakes and air outlets e Do not operate the appliance without the air filter THE MANUFACTURER DISCLAIMS ANY RESPONSIBILITY IF THE ABOVE INSTRUCTIONS ARE NOT FOLLOWED INTRODUCTION How it Works When the dehumidifier is started the fan begins to pull moisture laden air across the dehumidifying coils The coils condense or draw moisture from the air and air flows through the top louver into the room as dry warm air Moisture removed from air is collected in a drain bucket on the front of the dehumidifier The appliance is designed to operate between 41 F 5 C and 96 F 35 C The Compressor circuit has an automatic 3 minute time delayed start if the appliance is turned off and on quickly This prevents over heating of the compressor and possible circuit breaker tripping Make sure the drain bucket is fitted correctly otherwise appliance will not turn on Energy Saving Guide This Whynter dehumidifier is an Energy Star rated ap
8. not even which may cause the water to spill See Fig 3 and Fig 4 4 Remove the water from the drain bucket and replace it back to the dehumidifier The drain bucket must be installed properly and se curely seated for the dehumidifier to operate 5 The machine will restart when the drain bucket is restored in its correct position If the unit was turned off prior to the removal of the drain bucket press the Power button to restore operation NOTES e When you remove the drain bucket do not touch any inside parts of the unit Doing so may damage the product and result to injury Be sure to push the drain bucket gently all the way into the unit Banging the bucket against anything or failing to push it in securely may cause the unit not to operate If the pump filter drops when you remove the bucket see Fig 5 you must reinstall the pump filter properly to the unit before replacing the AL y drain bucket into the unit see Fig 6 ti ui n Pump filter Upon replacing the bucket firmly push the bucket in place until it ele ON Fig 6 locks There should be no gaps between the bucket and the dehu midifier When the drain bucket is removed the unit will beep 8 times and the digital display shows Eb Eb is an error code that indicates that the drain bucket is removed or not positioned correctly Make sure Push up pump that the drain bucket is properly installed and the in right position TS filter in pla
9. of microbes such as viruses fungi and spores WARNING NEVER OPERATE THE DEHUMIDIFIER WITHOUT THE FILTER START OPERATION 1 Ensure that the appliance is connected to the power socket 2 Make sure the drain bucket is placed in proper position 3 Make sure filter is installed Fig 1 4 When the unit is turned on for the first time if the bucket full lamp lights up just pull out the drain bucket then push it back to the proper position Fig 2 5 Set the relative humidity level RH by pressing the lt and gt buttons We recommend setting the RH to at least 10 lower than the current RH Fig 1 Fig 2 10 OPERATION INSTRUCTIONS 20 or more Air Outlet Air Intake 10 or more 10 or more 10 orlmore 10 or more POSITIONING THE UNIT This dehumidifier is intended for indoor residential applications only and should not be used for commercial or industrial applications Place the dehumidifier on a smooth hard and level floor strong enough to support the appliance with a full bucket of water Do not attempt to roll the appliance over objects Avoid placing the appliance in an area where the temperature will fall below 53 F The coils may become cov ered with frost and may reduce performance Do not place the appliance near clothes dryer heater or radiator Shut all doors wndows and openings to your target dehumidifying space for maximum performance Allow at least 10 of ai
10. outlet Fig 9 eee wee Pump filter 13 MAINTENANCE CAUTION Always turn off and unplug the dehumidifier before cleaning 1 Cleaning the air grille and main unit e Use a damp cloth to wrap the main unit or use water and a mild detergent Do not use bleach chemicals or abrasives e Do not splash water directly onto the unit Doing so may cause an electrical shock cause the insulation to de teriorate or cause the unit to rust e Use a vacuum attachment or brush to clean the air intake and outlet grilles 2 Cleaning the bucket e Clean the bucket to prevent growth of mold mildew and bacteria every two weeks e Fill the bucket with clean warm water and add mild detergent to the water e Dry thoroughly before reinserting the bucket to the main unit NOTE Do not clean the bucket in a dishwasher 3 Cleaning the air filter To ensure the air intake is filtered properly and to assure that your dehumidifi er runs efficiently it is recommended to clean the air filter at least once every two weeks e Use a vacuum cleaner or tap the filter lightly to remove loose dust and dirt e Rinse the air filter under warm or cold running water no hotter than 100F e Dry thoroughly before reinserting the air filter e Reinstall the air filter and replace bucket securely 4 End of Season Storage e After turning off the unit wait 24 hours before emptying the bucket to allow excess moisture to drain into the bucket
11. troubleshooting suggestions below to see if the problems can be resolved before having to contact the service department The dehumidifier does not operate The dehumidifier runs too much The dehumidifier runs but the room is not dry enough Frost appears on the coils above the bucket The dehumidifier makes loud noise Power failure outage The automatic switch line fuse or breaker has been tripped The power supply voltage is too low The power cord is damaged The dryness level you selected has been reached Drain bucket is full or not positioned properly Windows or doors near dehu midifier are open Area to be dehumidified is too large Air movement through dehu midifier is blocked Air grille may be dirty Continuous mode is on Humidity setting RH is too high The dehumidifier does not have sufficient clearance to operate Room temperature is too low Windows or doors are opened The dehumidifier has been turned on recently Room temperature is too low Appliance is not leveled 16 Restore the power supply Flip the switch change the fuse turn the breaker back on Also note that you may have too many appliances drawing power on one circuit you may need to move the other appliances to another circuit Move the appliance onto another circuit with the correct voltage Call for service Only authorized person nel should replace damaged power cord or power plug
12. 4 Continuous Button Press to activate the Continuous dehumidifying operation The Continuous indicator light will come on when this mode is selected To stop continuous operation press the Continuous CONT Button and set the desired RH per centage value to resume normal operation Note The Humidity Set Control Buttons will be disabled The compressor will not stop unless the drain bucket is full or is removed 5 Turbo Button Press the Turbo button to engage Turbo Fan mode The Turbo indicator light will come on when this speed is se lected Press the Turbo button again to set the unit to Normal Fan mode The Turbo indicator light will turn off when Normal Fan mode is activated PARTS AND CONTROLS 5 Timer Button Press to activate the Timer delay feature in conjunction with the Timer Control Buttons Timer Delay Switch Off When the appliance is ON press the Timer button to activate Auto stop function and the Timer OFF light will come on Set the desired time delay OFF hours by pressing the 4 and gt buttons The time increments are 1 hour up to 24 hours When the delay time set has elapsed the appliance switches off To cancel the delayed switch off function set the time to 00 or turn off the appliance Timer Delay Switch On When the appliance is OFF press the Timer button to activate Auto start function and Timer ON light will come on Set the desired time delay ON hours by pressing the lt and buttons The
13. ce 12 WATER DRAINAGE INSTRUCTIONS 2 CONTINUOUS GRAVITY DRAIN METHOD Water can be automatically emptied into a floor drain by attaching the 20 continuous gravity drain hose to the con tinuous gravity drain outlet To use gravity to drain your portable dehumidifier it must be installed on a level surface or at least 12 inches above the ground on a sturdy table or shelf unit When using the function of continuous gravity drainage your drain hose must be placed horizontally below the drainage hole Avoid uneven ground and folding the hose 1 Remove the continuous drain cover and then attach the 20 con tinuous gravity drain hose Make sure the hose is securely fastened to prevent leakage 2 Direct the drain hose toward a drain or other suitable drainage outlet Make sure that there are no distortions with the hose that may stop the water flow See Fig 7 3 Select the desired humidity setting and fan speed on the unit for continuous draining to start NOTE When using continuous gravity drainage setup there may be some water collected in the water in the drain bucket 3 WATER PUMP METHOD One of the key features of this dehumidifier is that it has a water pump that pushes water up or over a longer dis tance Using this feature will enable your unit to run maintenance free NOTE The water pump will ONLY engage when the drain bucket is full 1 Make sure the continuous gravity drain assembly is removed from
14. e caused by consumer misuse tampering or failure to follow the care and special handling provisions in the instructions e Damage to the finish of the case or other appearance parts caused by wear e Damage caused by repairs or alterations to the product by anyone other than authorized by the manufacturer e Freight and Insurance cost for the warranty service STOO Oca NA AR Zam 0 O n E Mm U O lt m A ep 0 O M m U gt lt D CS gt A E WO D O ZU Z m lt m gt A Z JIU O CZ COPWO JE VZL 3204 m gt Zz57 lt oz m y m SPEVY TIN CH T C x O TT C So O Z YN gt lt Z O gt U U r lt H VI lt O C lt gt lt gt M Cp O sE gt lt m O E mM A D Q I OA L gt E Aas gt ZJO lt H gt M oe lt po O lt U H gt m O U gt m To obtain service or information contact Whynter LLC via email at service whynter com or call 866 WHYNTER Product contents and specifications may change without notice Copyright 2015 Whynter LLC WWW WHYNTER COM 18
15. ily room If your home is musty you will want to use your portable dehumidifier especially if you have respiratory trouble or allergies This unit can also help relieve symptoms by controlling the relative humidity inside your home and a good idea in general if your home has such underlying problems as a leaky foundation walls or inadequate ventilation or if you live in a humid area By keeping the relative humidity indoors below 50 percent you can keep allergy inducing dust mites and mold from thriving 3 Basements If you have a basement that is below grade you should use your Whynter Portable Dehumidifier This de humidifier will help you keep the moisture levels in your basement down to manageable levels By doing this you can help keep your indoor furnace operating efficiently and even help eliminate minor standing water problems Your portable dehumidifier also can help keep furniture and valuables dry and it will help keep electronics in proper working order 4 Humid climates In humid climates such as areas near a beach or large body of water this Whynter Portable Dehumidifier can help keep the environment in your home at a more comfortable level While the actual temperature won t be affected you ll sleep more comfortably and may actually save money since your unit can keep the indoor humidity and thus your thermostat under control 15 TROUBLESHOOTING Many common portable dehumidifiers problems are easily resolved Try the
16. ive humidity level from 35 RH to 85 RH e Once the RH is set the set RH will stay on the display for about 5 seconds then it will revert back to current RH e Shows Auto Start and Auto Stop time from 0 0 hour to 24 hours e After the option settings are completed the display shows the approximate room humidity level in a range of 30 RH Relative Humidity to 90 RH Error Codes and Protection Code AS Humidity Sensor Error Unplug the unit and plug it back in ee Sensor Unplug the unit and plug it back in Empty the drain bucket P2 Drain Bucket Full Please make sure float moves freely and is not stuck EC Unit Malfunction Please make sure whether the environment temperature is between 41 F 5 C and 96 F 35 C E3 Unit Malfunction Unplug the unit and plug it back in Drain bucket is removed or not positioned correctly Make Eb Drain Bucket Error sure that the drain bucket is properly installed and the in right position Auto Restart In the event of a power outage appliance restarts at the previously set function mode and settings when power is restored not applicable to Timer Function OPERATION INSTRUCTIONS AIR FILTERS INSTALLATION Your Whynter portable dehumidifier is equipped with a 2 in 1 silver coated washable pre filter combo This washable pre filter removes large particles such as dust pet hair and dander The silver coating is designed to kill bacteria in the air and control the growth
17. lation the power supply must not be excessively or dangerously bent or flattened e Do not tamper with controls e Make sure the power plug is placed fully and firm into the wall socket If the wall receptacle you intend to use is not adequately grounded or protected by a time delay fuse or circuit breaker have a qualified electrician install an outlet that is appropriate to local electrical codes and requirements e Do not use multiple socket or of an extension cord as it may overheat and become a risk of fire e Make sure the power plug is clean before usage e Do not turn this appliance on and off by plugging and unplugging Always use the ON OFF switch e After turning the appliance off please take the power plug out of the socket e Make sure hands are dry when connecting the power plug The appliance is equipped with a three prong grounded plug on the power cord for your protection Never modify remove or attempt to repair the power plug yourself e Do not repair disassemble and or modify the appliance by yourself e Always turn off the appliance when cleaning the air filter and transporting e At the end of each season all water must be drained from the appliance and air filter must be cleaned before storage e Do not drink or use the water collected or drained from the appliance e Do not remove the drain bucket during operation e Transport the appliance in an upright position only or leave it in an upright position for at least
18. n indicator light indicator light Indicator light Indicator light Indicator light Indicator light Display Comfort Dehumidifying Operation indicator light PUMP COMFORN FILTER CONT nae boron Filter Continuous Turbo Timer nae boron Button Button Button Button 1 Pump Button Humidity Timer Control Button Press to activate the pump operation The Pump indicator light will illuminate when water pump is in operation Note Make sure the pump drain hose is installed into the unit and the continuous gravity drain assembly is re moved from the unit before the pump operation is activated The water pump function will start when the drain bucket is full 2 Comfort Button Press to activate the Comfort Dehumidifying mode operation The Comfort Dehumidifying indicator light will come on when this mode is selected In this mode the unit will automatically control the room humidity in a comfortable range of 45 55 according to the room temperature The humidity setting function is automatically disabled To stop Comfort Dehumidifying operation press the Comfort button and set the desired RH percentage value to re sume normal operation 3 Filter Button The check filter indicator is a reminder to clean the air filter for more efficient operation The filter light will illuminate after approximately 250 hours of operation To reset after cleaning the filter press the Filter button and the light will turn off
19. pliance Follow the guide below can help to get the best performance and efficiency from your dehumidifier e Do not cover the air intake and outlet e Do not place the appliance in front of curtains or drapes to ensure they do not obstruct the air intake e Keep curtains blinds or drapes closed during the sunniest part of the day e Close all windows and doors e Indoor relative humidity should ideally be kept between 35 RH and 60 RH depending on the ambient temperature e Make sure the appliance is on a hard and level surface e To prolong the compressor s life please wait at least 3 minutes before turning the appliance back on after shutting it off e Inspect and keep the air filter clean by cleaning regularly e Perform routine maintenance TECHNICAL DATA EEV Liters per kW Hour Refrigerant R410A 8 110z PARTS AND CONTROLS CONTROL PANEL HANDLE MOIST AIR INTAKE DEHUMIDIFIED DRY AIR VENT DRAIN BUCKET AIR FILTER POWER CORD BUCKLE CONTINUOUS DRAINAGE OUTLET ROLL CASTORS WATER PUMP POWERED OUTLET POWER CORD OTHER ACCESSORIES 1 20 Continuous Gravity Drain hose Power Cord Buckle Installation For easy storage install the power cord buckle to the rear of the unit Once installed the power cord can be wrapped using the buckle for safe storage PARTS AND CONTROLS Continuous Bucket Full Timer On and Off RH and Timer Clean Filter Auto Defrost on Operation Turbo Fa
20. r space on all sides of the appliance for good air circulation and 20 or more above the appliance NOTE Dehumidifiers working in a basement will have little or no effect on adjacent enclosed rooms such as closets unless there is enough circulation of air in and out of the enclosed area If the appliance has been switched off and needs to be switched on again allow approximately three minutes for the correct operation to resume Select a suitable location and make sure you have easy access to the electrical outlet Ensure the air filter and drain bucket are correctly installed before switching the appliance on Always be careful when moving the appliance with a full drain bucket Ensure that the safety requirements and warnings detailed in this user manual are followed when operating this appliance 11 WATER DRAINAGE INSTRUCTIONS Using a portable dehumidifier requires that collected water be emptied frequently Draining water from this unit can be done in 3 different methods 1 DRAIN BUCKET METHOD 1 When the bucket is full the Full indicator light will light The com pressor and fan will turn off the Full indicator will light and a P2 code will be displayed 2 It is recommended to turn the unit off before removing the drain bucket 3 Grip the left and right handles of the drain bucket securely and carefully pull out the drain bucket Do not put the drain bucket on the floor because the bottom of the bucket is
21. s Gravity Drain method and Water Pump method make sure the hose is securely fastened to prevent leakage Direct the drain hose toward a drain or other suitable drainage outlet ONE YEAR LIMITED WARRANTY This WHYNTER portable dehumidifier is warranted to the original owner within the 48 continental states for one year from the date of purchase against defects in material and workmanship under normal use and service Should your WHYNTER portable dehumidifier prove defective within one year from the date of purchase return the defective part or appliance freight prepaid within two months of purchase after two months to one year cus tomer will be responsible for freight cost to Whynter s service department along with an explanation of the claim to Whynter LLC Please package the portable dehumidifier carefully in its original packaging material to avoid damage in transit Please retain the original box and packaging material Under this warranty Whynter will repair or replace any parts found defective This warranty is not transferable After the expiration of the warranty the cost of labor and parts will be the responsibility of the original owner of the appliance THIS WARRANTY DOES NOT COVER e Acts of God such as fire flood hurricanes earthquakes and tornadoes e Damage accidental or otherwise to the portable dehumidifier while in the possession of a consumer not caused by a defect in material or workman ship e Damag
22. time incre ments are 1 hour up to 24 hours When the delay time set has elapsed the appliance turns on To can cel the delayed switch on function set the time to 00 or turn off the appliance Timer Delay Switch On and Off Sequence When the appliance is OFF press the Timer button to activate Auto start function and Timer light ON will come on Set the desired time delay ON hours by pressing the 4 and buttons Once Timer Delay Switch On is placed press the Timer button again to activate Auto stop function and the Timer OFF light will come on Set the desired time delay OFF hours by pressing the 4 and buttons When the delay time set has elapsed the appliance switches off To cancel the delayed switch off function set the time to 00 or turn off the appliance 6 Humidity Timer Control Buttons e Humidity Set Control Buttons The humidity level can be set within a range of 35 RH Relative Humidity to 85 RH in 5 increments For lower humidity level press the 4 button and set to a lower RH percentage value For higher humidity level press the b button and set to a higher RH percentage value Once the RH is set the set RH will stay on the display for about 5 seconds then it will revert back to current RH e Timer Set Control Buttons If Timer Button is pressed use the lt and gt buttons to set the Auto Start and Auto Stop time from 0 0 hour to 24 hours 7 Power Button Press to turn the dehumidifier on and off
23. vity drain hose is loose Cracked drain bucket Power failure or outage The automatic switch line fuse or breaker has been tripped The power supply voltage is too low The power cord is damaged The dryness level you select ed has been reached Drain bucket is full or not positioned properly Water pump filter is dirty Water pump drain hose is ob structed or kinked Drain bucket is not installed properly Drain hose connection may be loose or not installed properly 17 Secure the drain hose Contact Whynter Service Department Restore the power supply Flip the switch change the fuse turn the breaker back on Also note that you may have too many appliances drawing power on one circuit you may need to move the other appliances to another circuit Move the appliance onto another circuit with the correct voltage Call for service Only authorized person nel should replace damaged power cord or power plug If you want to remove more moisture set the unit on Continuous operation Empty drain bucket and insert the bucket to the appliance properly Clean the filter of the pump Make sure that the water pump drain hose is not obstructed Install the drain bucket securely Make sure that the drain hose is securely installed in the drain outlet For Drain Bucket method make sure that the continuous drain assembly is not in stalled and rubber drain cover is in place For Continuou
Download Pdf Manuals
Related Search
Related Contents
Introduction to the Altera SOPC Builder Using VHDL Design SuperH Family E10A-USB Emulator Additional Document for User`s 取扱説明書 取扱説明書 IOPI® User Manual HP Laserjet P4510 series - Fortin Fournitures d`Impression Ryobi DP121L Drill User Manual Gabarit de fraisage Lamello Copyright © All rights reserved.