1. If the user code is wrong the keypad buzzer will emit a long beep Press 7 and start entering the code again After entering the user code and ARMED LED turning on exit the objective through Entry Exit zone before exit time was over After exit time was over all LEDs will turn off but ARMED LED Exit time value is 120s by default In order to chande it see section 06 System parameter programming menu Before arming the system make sure that all protected zones doors and windows are closed Leave the rooms protected by PIR detectors If System LED is lit check the following the alarm memory 5 command If there are alarms in the memory they will be cleared when arming the system bypassed zones 3 User code command Make sure that all zones displayed as being bypassed are intentionally bypassed system state 4 command If there is trouble with the battery or the 220Vac power fix them before arming If READY LED is not lit then one or more zones are open The system cannot be armed unless Ready LED is lit 6 Cerber C41S User MANUAL INSTANT PERIMETER ARMING INSTANT STAY 1 User Cone This arming mode is used for perimetral protection Thus the user can stay inside the protected area i e arming the panel at night while staying home and no guest is expected After pressing the user code the system automatically isolates the STAY zones inside th
2. active siren period OPERATION BRIEFING ARMING User code Normal arming 0 0 Comlpeted quick arm 0 1 QUICK INSTANT STAY 0 2 INSTANT STAY 1 User code Instant stay arming 2 User code Stay arming DISARMING User code ZONE BYPASSING 3 User code By pressing the corresponding keys bypassing is enabled disabled 13 Cerber C41S UsER MANUAL SYSTEM STATE DISPLAY 4 After this command LEDs will show Zone 1 LED Zone 2 LED Low batery 220Vac loss ALARM MEMORY DISPLAY 5 After this command the first 9 alarms which have occured since last arming can be visualisedby pressing the keys from 1 to 9 By pressing key 0 all alarmed zones will be displayd simultaneously CuivE ON OFF 6 This command enables disables Chime function 3 beeps will confirm function enabling one long beep will confirm function disabling PROGRAM MobIFY USER CODES 7 Master code The next operations can be performed after this command CHANGING ADDING A CODE ERASING A CODE Code number New code number Code number MONOSTABLE ACTIVATION COMMAND 9 User code 14 Cerber C41S User MANUAL WARNING LIMITATIONS OF THIS ALARM SYSTEM Since this system is an advanced design security system it does not offer protection against burglary fire or other emergency butwarning Any alarm system whether commercial or residential is subject to
3. compromise or failure to warn for a variety of reasons For example Intruders may gain access through unprotected openings or have the technical sophistication to bypass an alarm sensor or disconnect an alarm warning device Intrusion detectors e g passive infrared detectors smoke detectors any many other sensing devices will not work without power Battery operated devices will not work without batteries with dead batteries or if the batteries are not put in properly Devices powered solely by AC will not work if their AC power supply is cut off for any reason however briefly Ausermay notbe able to reach a panic or emergency button quickly enough Smoke detectors may not activate or provide early warning for a variety of reasons Some of the reasons smoke detectors used in conjunction with this system may not work are as follows Smoke detectors may have been improperly installed and positioned Smoke detectors may not sense fires that start where smoke cannot reach the detectors such as chimneys in walls or roofs or on the other side of closed doors Smoke detectors may not sense a fire on another level of a residence or building A second floor detector for example may not sense a first floor or basement fire Moreover smoke detectors have sensing limitations No smoke detector can sense every kind of fire every time In general detectors may not always warn about fires caused by carelessness and safety hazards like smoking i
4. sere beo p chest e ea creux 10 Door Chile On OIT uere tae a eo to tete PERO Fee RUE sandal a Kad ava ug 10 Program Modify User Codes 241 Monostable activating Command 5 crore otto tete ente crei co Fee cca cerros 12 Keypad ala srnu itta reet nde eget Peter pt gute bus ta due 12 Operation briefing etd Warning Limitations of this Alarm System aaaaaaavaaaaaaisansaaasnnnsaannnnnnnnnnnnannnnnnnnnnnnna 15 Cerber C41S User MANUAL INTRODUCTION BASIC FEATURES Cerber C415 is a digital interfaced alarm control panel for small and medium objective radio monitorization It is ideal for flats villas company headquarters where a local burglary system or remote radio central station monitorization is needed Cerber C418 is a keypad operated burglary system with built in monitoring facilities alarm memory the first 9 events could be displayed on the keypad 1 Installer code 1 Master code 14 user codes and 1 Duress code The system multiple facilities are KP 04LED keypad programmable The central unit is up dated and RISC microprocessor designed The electric scheme also includes an EEPROM memory Thus the programmed parameters are retained even after all power was removed from the control panel The next basic features are common to the system 4EOLzones programmed as Prewarning Entry Exit Instant Follower 24 hour tamper 24h medical emergency 24h fire 24h pan
5. the user should leave the protected area before Exit time was over After the Exit time was over the whole system will arm and the Armed LED will stay lit Quick ARM iN INSTANT PERIMETER Mone QUICK INSTANT STAY 110 1 Similar to Instant Perimeter Arming INSTANT STAY Quick Arm iN PERIMETER Mone QUICK STAY 0 2 Similar to STAY arming DISARMING User cope One can only enter the protected area through an Entry Exit zone While opening Entry Exit zone Entry time will begin counting Keypad buzzer will sound a continuous beep during the Entry time indicating that the system should be disarmed Press one of the access codes 1 to 15 If wrong press key and repress the code again The Armed LED will turn off and so will the buzzer If the system is not disarmed during the Entry time the panel will alarm Note In order to modify the Entry time see system parameter programming section 06 Cerber C41S User MANUAL MISCELLANEOUS ZONE BYPASSING 3 User cone Zone bypassing can be done only if the system is disarmed The initiating devices from a bypassed zone will not be considered by the panel Zone bypassing is used when access is needed in that particular zone even if the system is armed a sensor is out of order or wiring is defective Zone bypassing is also used when some initiating devices or wires are damaged and restoring is not immediately possible Arming can be done
6. K2 EOL zones e 1 Keyswitch and all 24h type 2K2 EOL zone Main board outputs e 5 open collector outputs with negative trigger NPN transistors max 400mA PGMs e 2 open collector outputs with negative trigger NPN transistors max 5 CLK and DATA e 1 open collector siren output with positive trigger PNP transistor tipical consumption 500mA max 1A Cerber C41S UsER MANUAL OPERATION Zone LEDs READY LED SYSTEM LED ARMED LED The keypad is the device which helps program the system enter data and display system state System operation is done using the keypad and the indications of LEDs located in front of the keypad There are 4 zone LEDs and 3 state LEDs READY SYSTEM ARMED on the keypad OPERATION CODES The system recognizes 1 Master code code 0 14 user codes codes 1 to 14 if they have been programmed 1 Duress code code 15 necessary in case of transmission to a central station and 1 special code installer code Master code code 0 is programmed by default The default value for the Master code is 1234 Using the Master code one can operate the system and program the other user codes as well The allowed operations are Arming Disarming Zone Bypass Zone Bypass Cancelling Operating code programming Monostable PGM output enabling User codes codes 1 to 14 not programmed by default The allowed operations are Arming Disarming Zone Bypass Zone Bypass Cance
7. USER BOOK Doc 10101 13 04 00 Version 1 11 Cerber C41S 4 zone 1 special zone burglary control panel with a digital interface for radio monitoring Cerber C41S User MANUAL Table of Contents INTRODUCTION echt soe Pacts aa aE tes deese noctes coco eat Seep tei ete coca erre ren 3 BASIC featues 5 oen rtm er Eh DR Pe ERE CO ERE X EE EDO STEATE 3 Technical Specifications noinine oa aek N ENEE adaa EEE R aaa 4 OPERATION ninna nia a aE K a B Val p a Eaa a aad lag 5 Operation COdE Sansir uo tT t aV laa even aare N E ETa taresinaa sats 6 Installer Programming Code 0269 by default ccccceccceseseeceeeeeeeeeeeeaeeseaeeseneeseeeeesenes 6 AIMN ae a a nanneee ate 6 Instant perimeter arming Instant stay erroris irienner 7 Perimeter arming Instant Stay icri errore oe dne e reete bci oe edet 7 Quick Arming Modes no code Te Ulred i ddscdasssndskanksanuslastavudnadassnadsnandatbeinasrn 8 Quick arm completed cn e UR PR EE ED ER REEL aries 8 Quick arm in Instant Parameter Mode neret a inns 8 Quick arm im Parameter Mode scion a a rr oes 8 DISARMING D 8 WIESEN OU C M 9 ZODe DVDBSSIIOE A ics eorr pecs ccset ven dent ca detur re sera sse PAM Rise MEER E E Ud ee A I IE cece 9 Syst m State DISplay A ta 9 Alarm Memory Display uoc derriere eee nee reise corta reti
8. e house That is why the yellow System LED will turn on during exit delay After the Exit time was over delayed zones will become Instant and they will trigger an alarm the very moment they are opened Perimeter zones are those which have not been designated as STAY type by the installer The red Armed LED will blink instead of being steady indicating that the delayed zones are instant now PERIMETER ARMING STAY 2 User Cone This arming mode is also used for perimetral protection This time the user also stays inside the protected area but is allowed access through the Entry Exit zones After pressing the user code the system automatically isolates the STAY zones inside the house Thus the yellow System LED will turn on during Exit delay After the Exit time was over the whole system will arm in a perimeter mode Entry Exit zones keep their characteristics and the Armed LED will stay lit Any code user 1 15 can enter the building thruogh Entry Exit zones During the entry lapse of time the code user may enter his her own code in order to disarm the system Cerber C41S UsER MANUAL Quick ARMING MODES No CODE REQUIRED This function will be used by someone who doesn t own an access code This arming mode can also be used when arming in presence of someone who must not finf out the user code Quick ARM COMPLETED 0 0 Arming will be done by pressing the sequence 0 0 Next
9. fic Finally alarm warning devices however loud may not warn hearing impaired people or waken deep sleepers Telephone lines needed to transmit alarm signals from a premises to a central monitoring station may be out of service or temporarily out of service Telephone lines are also subject to compromise by sophisticated intruders Eventhe system responds to the emergency as intended however occupants may have insufficient time to protect themselves from the emergency situation In the case of a monitored alarm system authorities may not respond appropriately The most frequent cause of an alarm system not functioning when an intrusion or fire occurs is inadequate maintenance This alarm system should be tested weekly to make sure all sensors are working properly 15 ROMANO ELECTRO INT L innovating for EJ safer life 27 29 Calimachi Str Sect 2 72266 f Bucharest ROMANIA TA Tel 40 1 242 20 20 Fax 40 1 242 20 30 E mail tehnic roel ro www roel ro
10. having one or more zones bypassed even if sensors on these zones are open While the system is disarmed press 3 Access code to display the bypassed zones The System LED will blink and the corresponding zone LEDs will be lit To bypass a zone press the corresponding digit while the corresponding LED will turn ON To cancel zone bypassing press the corresponding digit while the corresponding LED will turn OFF If the zone corresponding to the key pressed does not have the feature able to be bypassed set up this feature can be modified as in sections 01 04 bypassing will not be allowed which is confirmed by a long beep fro the keypad buzzer and the LED corresponding to that key will still be off Note 24h zones cannot be bypassed If one 24h zones one of 1 to 4 zones had the able to be bypassed feature set up before having declared it a 24h one then when entering 3 User code sequence the keypad will confirm 24h zone bypassing However the 24h zone will not be actually bypassed Exit bypassing mode by pressing NOTE When disarming the system the bypassed zones will be cleared SYSTEM STATE DISPLAY 114 The alarm system monitors some trouble conditions If one of these conditions occurs the System LED will turn ON To display these conditions press 4 The conditions will be displayed on zone LEDs as follows Zone 1 LED Low Battery if the battery is disconnected or LOW this LED is li
11. ic e 1 special EOL zone programmed as 24h tamper 24h medical emergency 24h fire 24h panic keyswitch arming disarming Keypad programming 1 programmable user code 1programable Master code e 14 user codes 1 Duress code all programmable Quick arming Stay arming Instant stay arming e 4zone attributes each individually programmable ZoneBypass Programmable Chime function Programmable Bell cut off time Steady Pulse or Silent programmable alarming periods Programmable Entry delay Exit delay Optional Keyswitch arming disarming Cerber C41S USER MANUAL Qoptions for 5 programmable outputs which are Latch on alarm Arm ing Disarming Entry delay Exit delay Trouble Steady siren Pulsing siren Silent alarm Panic Monostable Monostable programmable output enabling for all user codes Alarm memory the first 9 alarm events are displayed on keypad 2Digital outputs CLK and DATA used for radio transmission Monitoring system battery and AC power state Individual state LEDs for 1 to 4 zones indicating the alarm state Systemstate LEDs READY SYSTEM ARMED e Current limitation for back up battery loading 220mA TECHNICAL SPECIFICATIONS Power e 12V 4Ah battery e 14Vac 20VA power transformer e stand by current control panel 100mA keypad 12mA 2A maxim power output on AUX power supply tipical 1A 2 2A protected Inputs 4 fully programmable 2
12. lling Monostable PGM output enabling Duress code Ambush code 15 not programmed by default If the control panel also uses the transmission to a central station when disarming the system using code 15 the panel will transmit a special code meaning that the system was disarmed under threat If radio transmission is not used code 15 can be used as any other user code Code modifying including Master code is done by 7 Master Code command Cerber C41S User MANUAL INSTALLER CODE 0269 By DEFAULT Only the system installer is entitled to have this code Making use of this code the installer has access to the system parameter programming menu except user functions The default Installer Code is 0269 Control panel parameter programming is achieved by this code and the 8 Installer s code command only if the control panel is disarmed system user s agreement is necessary This code should be changed after system installing Note The control panel is provided with an option for valid code guessing attempts without regards to the type of code Master user installer After successively entering 10 wrong codes the keypad will no longer take commands for the next 8min ARMING USER CODE In order to arm the system enter a 4 digit user code When pressing each digit the keypad buzzer will emit a short beep After entering the user ode ARMED LED will turn on and the keypad buzzer will emit 6 beeps
13. n bed violent explosions escaping gas improper storage or flammable materials overloaded electrical circuits children playing with matches or arson Depending on the nature of the fire and or the location of the smoke detectors the detector even if operates as anticipated may not provide sufficient warning to allow all occupants to escape in time to prevent injury or death Passive Infrared Motion Detectors can only detect intrusion within the designed ranges as diagrammed in their installation manual Passive Infrared Detectors do not provide volumetric area protection They do not create multiple beams of protection and intrusion can only be detected in unobstructed areas covered by the beams They cannot detect motion or intrusion that take place behind walls ceiling floors closed doors glass partitions glass doors or window Mechanical tampering masking painting or spraying of any material on the mirrors windows or any part of the optical system can reduce their detection ability Alarm warning devices such as sirens bells or horns may not alert people or wake up sleepers who are located on the other side of closed doors If warning devices sound on a different level of the residence from the bedrooms then they are less likely to waken or alert people inside the bedrooms Even persons who are awake may not hear the warning if the alarm is muffled by noise from a stereo radio air conditioner or other appliances or by passing traf
14. ramming to factory default settings see Commissioning In this programming modifying mode Ready System and Armed LEDs will blink continuously After having completed all desired changes exit this programming modifying mode by pressing 7 MONOSTABLE ACTIVATING COMMAND 9 User Cope When activating this command any output PGM1 PGM2 PGM3 PGM4 and PGM5 programmed as monostable will activate by negative triggering during the programmed lapse of time in section 9 system parameter programming menu KEYPAD ALARMS These events can be performed by pressing some keys simultaneously 1 and 3 Medical emergency alarm 7 and 9 Fire alarm 4 and 6 or and 7 Panic alarm 12 Cerber C41S UsER MANUAL Note 1 When the event Emergency Alarm is keypad generated the next will activate Silent siren will not be heard PGMs programmed with Silent Alarm feature value 7 in section 9 Programmable 1 5 PGM output type during active siren period even if it is silent 2 When the event Fire Alarm is keypad generated the next will activate Pulse siren PGMs programmed with Pulse Alarm feature value 6 in section 9 Programmable 1 5 PGM output type during active siren period 3 When the event Panic Alarm is keypad generated the next will activate Steady siren PGMs programmed with Pulse Alarm feature value 5 in section 9 Programmable 1 5 PGM output type during
15. rmed zones simultaneously To exit this display mode press 7 key The alarm memory will clear while arming the panel again Door CHIME On OFF 6 The Door Chime feature causes the keypad buzzer to sound 6 short beeps whenever an Entry Exit door is activated The feature is useful if the Entry Exit doors are out of view and the user desires an indication of when the door zones are opened The Door Chime feature works only when the system is disarmed To turn the feature on off enter 6 command If the feature is being turned 10 Cerber C41S UsER MANUAL ON the keypad buzzer will emit 3 beeps If the feature is being turned OFF the keypad buzzer will sound 6 beeps Note Chime feature is disabled by default Mopirv PRoGRAM Access Copes 1 15 7 Master Cove The 7 Master Code command allows Master user to modify all user codes but the installer code Enter 7 Master Code Ready LED will be off Armed LED will be lit System LED will start blinking and zone LEDs are off In order to choose the code to be entered modified enter the 2 digit code order number i e for Code 7 enter 07 this very moment the keypad will emit 3 beeps and zone LEDs will act as follows Note 1 If 1 2 3 and zone LEDs are blinking then the code has already been programmed 2 If only zone 1 LED is blinking then the respective code is not programmed 3 When the code is being p
16. rogrammed 1 and 2 zone LEDs are lit and READY SYSTEM and ARMED LEDs are blinking From this moment on the codes are to be modified as follows Changing or Adding a Code Code entering or changing can be cancelled by pressing A new code can be entered if the next sequence will be entered by keypad IXIXIXIXI where IXIXIXIXIisthe new 4 digit user code In order to issue another code its order number will be entered and the procedure will be resumed All 15 user code can be thus added or modified Note Do not press when entering the code 11 Cerber C41S User MANUAL Erasing a Code After entering a code order number the keypad buzzer will emit 3 beeps and 1 2 3 and 4 zone LEDs will blink if the respective code does exist If the respective code has not been previously programmed only zone 1 LED will blink If the code does exist in order to erase it press this key being the first one to be pressed after the order number was entered In this case the keypad buzzer will emit 6 beeps If key is not the first one to be pressed but the second the third or the fourth the current code will not be erased the old code being kept In this case the keypad buzzer will emit a long beep Erasing all codes If 2 0 keys are pressed all codes will be erased but Master code The keypad will emit 6 beeps NOTE Never erase Master Code If by mistake the Mater Code is erased reset system prog
17. t The LED will tum OFF within 8 seconds after restoring the battery Cerber C41S User MANUAL trouble Zone 2 LED AC Power OFF if AC power is OFF or the transformer is burnt this LED is lit The LED is also lit if AC power circuit fuse is burnt The LED will turn OFF instantly after restoring AC power trouble To exit this mode press key ALARM Memory DisPLAY 1 5 The first 9 alarms produced during the last arming are memorized and can be visualized on the keypad LEDs To display the alarmed zones press 5 System LED will blink and so will the LEDs of the last alarmed zones 1 to 4 One can press 1 to 9 keys in order to visualize the first 9 alarmed zones during the last arming of the panel Pressing the key 1 one of zone LEDs will turn on showing the first zone alarmed while pressing the key 9 one of zones LEDs will turn on showing the most recently alarmed zones Note LED interpreting when presing one of the keys from 1 to 9 is done as follows 1 If LED 1 is lit and SYSTEM LED is blinking READY LED is off then an alarm has occured in zone 1 2 If LED 2 is lit SYSTEM LED is blinking READY LED is off then an alarm has occured in zone 2 3 If LED 3 is lit SYSTEM LED is blinking and READY LED is off then an alarm has occured in zone 3 4 If LED 4 is lit SYSTEM LED is blinking and READY LED is off then an alarm has occured in zone 4 Pressing the key 0 one can see all the ala