Home
Intellipack Manual
Contents
1. Battery state 4 The battery needs charging At this stage some E of the functionality of the lift is lost At this battery stage it is only possible to drive the lifting arm down Furthermore an audio signal will be provided when a control button is activated The symbol will switch between the two pictures The battery symbol is shown when the box is awake until power down 2 minutes after use Charging of battery When the mains cable is plugged in and a control button is activated the symbol to the left is Shown at the display The purpose of the symbol is to tell the user that usage of the lift is not possible as the mains is plugged Service The control box will show the service symbol when it is time for service The standard setting is after 12 months 8000 cycles The first time that the service symbol is show the control box will provide an audio sound 1 second so that the user gets a note about checking the display Even though it is time for service the system will still be functional and work as normal Overload When overload occurs according to the pre defined current cut off limit the overload symbol will be shown on the display The MAX text will blink 3 times and the overload symbol will be shown for 10 seconds in total Service information read out Some basic service info can be read out on the display To get the service information on the display please press the liftin
2. E mail info linak de www linak de INDIA LINAK A S India Liaison Office Phone 91 120 4273708 Fax 91 80 2224 3863 E mail info linak in www linak in IRELAND LINAK UK Limited Phone 44 0 121 544 2211 Fax 44 0 121 544 2552 E mail sales linak co uk www linak co uk ITALY LINAK ITALIA S r l Phone 39 02 48 46 33 66 Fax 39 02 48 46 82 52 E mail info linak it www linak it JAPAN LINAK K K Phone 81 45 533 0802 Fax 81 45 533 0803 E mail linak linak jp www linak jp MALAYSIA LINAK A S Asian Representative Office Phone 60 4 210 6500 Fax 60 4 226 8901 E mail info linak asia com www linak asia com NETHERLANDS LINAK Actuator Systems B V Phone 31 76 5 42 44 40 Fax 31 76 5 42 61 10 E mail infoGlinak nl www linak nl NEW ZEALAND LINAK New Zealand Ltd Phone 64 9580 2071 Fax 64 9580 2072 E mail nzsales linak com au www linak co nz NORWAY LINAK Norge AS Phone 47 32 82 90 90 Fax 47 32 82 90 98 E mail info linak no www linak no POLAND LINAK Polska Phone 48 22 500 28 74 Fax 48 22 500 28 75 E mail dkreh linak dk www linak pl SPAIN LINAK Actuadores S L Phone 34 93 588 27 77 Fax 34 93 588 27 85 E mail linakact linak es www linak es SWEDEN LINAK Scandinavia AB Phone 46 8 732 20 00 Fax 46 8 732 20 50 E mail infoGlinak se www linak se SWITZERLAND LINAK AG Phone 41 43 388 31 88 Fax 441 43 3
3. aluminium and alloy steel Plastic can e g be divided into ABS PA PE and PP The can be disassembled and sorted into the following recycling groups Plastic housing Plastic recycling or combustion CBJ Cable Cable scrap or combustion PC board Electronics Scrap By now all our casted plastic units are provided with an interior code for plastic types and fiber contents if any 23 DECLARATION OF CONFORMITY LINAK A S 8 DK 6430 Nordborg hereby declares that LINAK Actuator System composed of Control Box CBJC with without internal charger And Linear Actuator s LA28 and or Linear Actuator s LA31 and or Linear Actuator s LA34 and or Linear Actuator s LA44 And Battery Box BAJ1 and or Battery Box BAJ2 And Handset HB5X and or Handset HB7X and or Handset HB8X And External Charger CHJ2 and or External Charger 00CH01 xx complies with the EMC Directive 2004 108 EC according to following standards EN60601 1 2 2007 EN 61000 3 2 2006 and EN 61000 3 3 2008 and complies with Low Voltage Directive 2006 95 EC according to the standard EN 60601 1 1990 A1 1993 A2 1995 Additional information The system does also comply with the standard EN ISO 10535 2007 Hoists for the transfer of disabled persons Requirements and test methods clause 4 3 1 23 Date 2010 01 27 Signature hr John Kling Certification and Regulatory Affairs LINA
4. and we therefore reserve the right to carry out technical modifications LINAK A S Important information Description of the various signs used in this manual Warning Failure to comply with these instructions may result in accidents involving serious personal injury nel Failing to follow these instructions can result in the product being damaged or destroyed Safety instructions A Safe use of the system is possible only when the operating instructions are read completely and the instructions contained are strictly observed Failure to comply with instructions marked with the NOTE symbol may result in serious damage to the system or one of its components Persons who do not have the necessary experience or knowledge of the product products must not use the product products Besides persons with reduced physical or mental abilities must not use the product products unless they are under surveillance or they have been thoroughly instructed in the use of the apparatus by a person who is responsible for the safety of these persons Moreover children must be under surveillance to ensure that they do not play with the product ate It is important for everyone who is to connect install or use the systems to have the necessary information and access to this User Manual If there is visible damage to the product it must not be installed the appliance is not intended for use by young children infirm persons Y w
5. 4 Fax 421 517563 410 E mail jp linak sk www linak com USA LINAK U S Inc North and South American Headquarters Phone 1 502 253 5595 Fax 1 502 253 5596 E mail info linak us com www linak us com SUBSIDIARIES AUSTRALIA LINAK Australia Pty Ltd Phone 61 3 8796 9777 Fax 61 3 8796 9778 E mail sales linak com au www linak com au AUSTRIA LINAK GmbH Austria Phone 43 0 2746 210 36 Fax 43 0 2746 210 44 E mail info linak de www linak at BELGIUM amp LUXEMBOURG LINAK Actuator Systems NV SA Phone 32 0 9 230 01 09 Fax 32 0 9 230 88 80 E mail info linak be www linak be BRAZIL LINAK do Brasil Com rcio de Atuadores Ltda Phone 55 11 2832 7070 Fax 55 11 2832 7060 E mail info linak com br www linak com br CANADA LINAK Canada Inc Phone 1 905 821 7727 Fax 1 905 821 4281 E mail info linak ca www linak ca CZECH REPUBLIC LINAK C amp S S R O Phone 420581741814 Fax 420581702452 E mail ponizil linak cz www linak cz DENMARK LINAK DANMARK A S Phone 45 86 80 36 11 Fax 45 86 82 90 51 E mail linak linak silkeborg dk www linak dk FINLAND LINAK OY Phone 358 10 841 8700 Fax 358 10 841 8729 E mail linak linak fi www linak fi FRANCE LINAK FRANCE S A R L Phone 33 0 2 4136 3434 Fax 33 0 2 4136 3500 E mail linak linak fr www linak fr GERMANY LINAK GmbH Phone 49 6043 9655 0 Fax 49 6043 9655 60
6. 88 31 87 E mail info linak ch www linak ch TAIWAN LINAK A S Taiwan Representative Office Phone 886 2 250 80296 Fax 886 2 2508 3604 E mail info linak com tw www linak com tw TURKEY LINAK A S Turkey Representative Office Phone 90 312 4726338 59 Fax 90 312 4726635 E mail vozen linak com tr www linak com tr UNITED KINGDOM LINAK UK Limited Phone 44 0 121 544 2211 Fax 44 0 121 544 2552 E mail sales linak co uk www linak co uk DISTRIBUTORS ARGENTINA NOVOTEC ARGENTINA SRL Phone 54 11 4303 8900 89 Fax 54 11 4032 0184 E mail info novotecargentina com www novotecargentina com COLOMBIA MEM Ltda Phone 57 1 334 7666 Fax 57 1 282 1684 E mail servicioalcliente memltda com co www memltda com co INDONESIA PT HIMALAYA EVEREST JAYA Phone 6 221 544 8956 65 Fax 6 221 619 4658 1925 E mail hejplastic divecentrin net id www hej co id IRAN Bod Inc Phone 98 21 2203 9435 Fax 98 21 2203 9430 E mail info bod ir www bod ir MEXICO ILSA S A de Phone 52 55 5388 3960 Fax 52 55 5388 3966 E mail linak ilsamexico com www ilsamexico com RUSSIAN FEDERATION 000 FAM Phone 7 812 3319333 Fax 7 812 3271454 E mail purchase fam drive ru www fam drive ru SINGAPORE SERVO DYNAMICS PTE Ltd Phone 65 6844 0288 Fax 65 6844 0070 E mail servodynamics servo com sg www servo com sg SOUTH AFRICA Industrial Specialised
7. Applications Phone 27 11 312 2292 or 27 11 2077600 Fax 27 11 315 6999 E mail gartht isagroup co za www isaza co za SOUTH KOREA UNITEK ENG Phone 82 2 567 0888 Fax 82 2 3453 1177 E mail unitekeng unitekeng co kr www unitekeng co kr UNITED ARAB EMIRATES Mechatronics 971 4 267 4311 Fax 971 4 267 4312 E mail mechtronGemirates net ae www mechatronics ae For contact details on other countries please visit www linak com or contact LINAK INTERNATIONAL Fax 45 74 45 90 10 E mail info linak com www linak com Terms of use The user is responsible for determining the suitability of LINAK products for specific application LINAK takes great care in providing accurate and up to date information on its products However due to continuous development in order to improve its products LINAK products are subject to frequent modifications and changes without prior notice Therefore LINAK cannot guarantee the correct and actual status of said information on its products While LINAK uses its best efforts to fulfil orders LINAK cannot for the same reasons as mentioned above guarantee the availability of any particular product Therefore LINAK reserves the right to discontinue the sale of any product displayed on its website or listed in its catalogues or other written material drawn up by LINAK All sales are subject to the Standard Terms of Sale and Delivery for LINAK For a copy hereof p
8. HARGE FAN Battery 3 light emitting diodes JUMBO CARE Green There is no need to charge the battery Yellow Battery needs charging ext Yellow Battery needs charging Incl acoustic signal when the hand eqs control is activated When one continues to use the application at the lowest battery level the diode will blink and continue to give an acoustic signal At that time it will be possible to drive channel 1 lifting arm down but not up and leg spread is not possible ON CHARGE 4 1 What to read out on the display Below you find information about what to read out on the display version of CBJ Care Basically the functionality for the display version is the same as the diode version but more information can be read out on the display Driving information 4 M As long as a hand control button is activated driving information will be shown on the display Either lifting arm up lifting arm down legs in or legs out y The only exception to this is when the battery is flat stage 3 and 4 see below At that point the battery information will be show instead Battery The battery discharging will be shown in four stages Battery state 1 The battery is ok no need for charging Battery state 2 Battery needs charging Battery state 3 Battery needs charging Buzzer sound is provided when a button is pressed at this battery stage
9. K application policy The purpose of the application policy is to define areas of responsibilities in relation to applying a LINAK product defined as hardware software technical advice etc related to an existing or new customer application LINAK products as defined above are applicable for a wide range of applications within the Medical Furniture Desk and Industry areas Yet LINAK cannot know all the conditions under which LINAK products will be installed used and operated as each individual application is unique The suitability and functionality of the LINAK product and its performance under varying conditions application vibration load humidity temperature frequency etc can only be verified by testing and shall ultimately be the responsibility of the LINAK customer using any LINAK product LINAK shall be responsible solely that the LINAK products comply with the specifications set out by LINAK and it shall be the responsibility of the LINAK customer to ensure that the specific LINAK product can be used for the application in question 25 26 27 FACTORIES CHINA LINAK Shenzhen Actuator Systems Ltd Phone 86 755 8610 6656 Fax 86 755 8610 6990 E mail sales linak cn www linak cn DENMARK LINAK A S Group Headquarters Guderup Phone 45 73 15 15 15 Fax 45 74 45 80 48 Fax Sales 45 73 15 16 13 E mail info linak com www linak com SLOVAKIA LINAK Slovakia s r o Phone 421 517563 41
10. USER MANUAL We move body and mind INTELLIPAC LI NAK Contact 1 800 694 4525 WE IMPROVE YOUR LIFE www vancare com Contents Preface Important information Safety instructions Before start up During operation Maintenance Manufacturer s declaration IP Protection degree Environmental conditions Label Key to symbols System and compatibility General description control box General descripton external charger option CHJ2 General description batteries 2 nnne nennen CBJ Care versions What to read out of the diodes Service Battery What to read out on the display Driving information Battery Charging of battery Service Overload SOGVICE ART OMA redd oUt Seesen OA O 1 1 1 1 n Use of Service data tool with CBJ Care ninin ccoo eene nnne tenere 7 How to use the lowering lifting function on the control box 17 Learn mode for current cut off Learn mode function How to use learn mode Procedure for registration of max weight Precautions Hand controls for CBJ Care Mounting of CBJ Care Mounting brackets available Drawings Repairs Warrant
11. connected to the mains power T 1 a 1 Mains cable input internal charger version Channel 1 Channel 2 OLED display as option for CBJ Care Handset main lift leg spreader Diode display as option on CBJ Care actuator only actuator only The CBJ Care control box provides Switching and direction control for each actuator function when a button on the handset is pushed Two speed operation of the main lift actuator special option Current sensing electronic overload protection EOP to the actuators Indication of low battery condition via a built in buzzer When the buzzer sounds you need to charge the battery The buzzer will only be active when the handset is operated Option of OLED display or diode display showing battery condition Soft start stop function on channel 1 which reduces any sudden jolt when the actuator is starting or stopping Electrical emergency activation functions for up down operation of the main lift actuator In case of handset failure it is possible to operate the main lift actuator by using the point of a ball point pen in the positions marked on the front cover of the control box Red Emergency Stop Button that disconnects battery power to the control box Pushing the button activates the stop button To reset rotate the stop button clockwise until it releases Activation of the emergency stop interrupts all battery supply and prevents any functions from operating Whe
12. e CHJ2 charger or CBJ Care control box 24V capacity providing 2 9 Ah between 20 50 lifts depending on load actuator type and stroke e DC plug for charging of the battery pack by means of the CHO1 plug pack wall charger BAJ2 only or internal charger The batteries in the battery packs are of the lead acid type and require regular charging BAJ1 is the standard battery pack BAJ2 has a DC charging socket for connecting a plug pack charger LINAK type or 3 part charger versions JUMBO CARE IMB ARE JUMB Different versions of CBJ Care is available e gt No indicators on the front cover x Diodes on the front cover bor ve RER Display ni P No indicators Diodes on the Display What to read out of the diodes on the front front cover Service SOET Service indicator will blink yellow diode e Every 12 months norm EN10535 recommendation after 8000 Cycles whichever comes first Via a Hand control it is possible to reprogramme and set other service intervals see paragraph about hand controls for CBJ Care The first time that the service symbol is show the control box will pro vide an acoustic signal When it is time for service the service indicator will remain illuminated 2 minutes after use Afterwards the control box will power down to save the battery When the service indicator lights up the system will still be functional and work as normal JUMBO CARE ON C
13. e is exchanged it will be necessary to reset the max load to work within the requirements of EN10535 for the new system as a whole Hand controls for CBJ Care A CBJ Care can be used with a normal hand control That is HB50 HB70 or HB80 The general functionality for a hand control is seen below m Channel 1 Main lift Channel 2 leg spreader if fitted Diode lights up when hand control is activated until power down when connected to CBJ Care Only available on HB50 The CBJ Care can also use OpenBus hand controls e g HB80 OpenBus VO Two speed regulations of channel 1 is an option on CBJ Care when using an OpenBus hand control The two speed function of the lifting actuator is explained below Channel 1 main lift slow speed Channel 1 main lift fast speed Channel 2 leg spreader if fitted 19 A special HB7x OpenBus hand control item number HB7x235 00 has been created which must be used in order to activate the learn mode function WC iil To be activated while driving the lifting arm up with load see paragraph about learn mode The service interval can be changed via a HB80 OpenBus V2 handset tem number HB8646V2010 71 The hand control allows a service interval as number of months only number of cycles only or number of months and or cycles whatever comes first After having set a different service interval the control box will provide an audio sound as a receipt SERVICE INTERVALS do
14. equipment For indoor use Alternating Current Direct current Attention consult accompanying documents Demko approval Fimko approval Australian approval mark Australian approval mark Recognised Component Mark Canadian Recognised Component Mark Recognised Component Mark for Canada and the United States T Mark RW T v approval Produkt Service TUV Rheinland CS95145V LISTED File E97199 File E175209 File E151104 6 El x CE UL Listing Mark C UL Listing Mark C UL US Listing Mark UL Listing Mark UL file number UL file number c L file number CSA PSE Mark Product with a thermofuse Electronics scrap Equipment KI 2 Double square CE Mark C TICK China RoHS System and compatibility Channel 1 LA31 LA34 LA44 Channel 2 LA28 Standard and fast motors 24V LA31 Standard and fast motors 24V LA12 Standard motor LA30 Standard motor LA23 B Motor HB HB70 HB80 HD80 BAJ1 2 LA44 LA31 Spreader LA12 ud Precautions It is not possible to use other battery types than BAJ1 BAJ2 with the CBJ Care General description control box Green light ON indicates the charger Emergency stop Operation UP Operation DOWN If internal charger If internal charger Yellow light ON indicates the battery is charging light OFF indicates battery fully charged is
15. g By using the learn mode function it is possible to programme the LINAK CBJ Care so that the control box is able to lift max load but never more than 1 5 time max load How to use learn mode Load your lift with max load e Drive up using learn mode see detailed explanation on next page Your lift is now adjusted according to the norm EN10535 Your lift will always be able to lift max load e Your lift will never be able to lift more than 1 5 times max load Procedure registration of max weight Press the R button and also the UP button carried out in the area where the actuator lifts the greatest load Drive the lifting arm down and connect the special Put on the load which should be max load for the lift hand control HB7X235 00 When the actuator stops running the largest current simultaneously driving the lifting arm up If not driving value is registered and stored in the microprocessor at full stroke you have to make sure that the lift is When the current cut off value is stored in the microprocessor the control box will provide and audio sound After this the actuator will stop the current will cut off whenever max load is reached Precautions AN The registration function can only be activated by using a specially produced 18 handset HB7x235 00 A standard handset cannot activate the function e f an actuator or CBJ Car
16. g arm up button only Y second press The information will be shown for minute or until other buttons are activated Total cycles done by the lifting actuator channel 1 Total work done by the lifting actuator channel 1 Total number of overloads channel 1 Days since last service Days between services YY YY One cycle is defined as driving upwards with load for minimum 6 seconds The A S value Amps Seconds is an expression of the amount of work the actuator has done Use of Service Data Tool with CBJ Care Please see the manual service readout and Service Data Tool with CBJ Care for information about use of Service Data Tool within CBJ Care How to use the lowering lifting function on the control box On the control box there are either buttons or holes JUMBO CARE The lifting arm can be lowered or lifted via pressing e g a pen in the hole This is a permitted method of lowering lifting The lowering lifting buttons works as normal hand control buttons you do not get extended functionality by using these when the battery is low Learn mode for current cut off When choosing a CBJ Care it is possible to use the learn mode function to set the current cut off value Learn mode function The patient hoist norm EN10535 states that a patient hoist must not lift more than 1 5 times the max weight it is intended for For example if the lift is intended for max 100 kg it should not be able to lift more than 150 k
17. ic They must not break down grease The following disinfectants detergents are recommended Neodischer Dekonta dosage 1 396 made by CHEMISCHE FABRIK Dr WEIGERT CCOTRADE RW dosage 0 596 made by CCOTRADE GmbH Warning The systems must not be sprayed directly with a high pressure cleaner Environmental conditions Environment conditions Operating Temperature Relative humidity Atmospheric pressure 5 C to 40 C 20 to 90 30 C not condensing 700 to 1060 hPa Storage Temperature Relative humidity Atmospheric pressure 10 C to 50 C 20 to 90 30 C not condensing 700 to 1060 hPa Valid where nothing otherwise is stated under the specific products in a later section Labels Uin 400 240 V 50 60 Hz Max 400 mA 37 53 VA DESIGNED IN DENMARK U Out 24 V max 250 VA IPX4 KW 10 Max 2min 18min WE IMPROVE YOUR LIFE lin 0155 011014 int Date 2010 08 12 80 222222 exce CxO Condor IS UL Sta 606 4 ro am TIENI MADE BY LINAK DENMARK Cartified to CAN CSA Sta C22 2 No 6011 Key to symbols The following symbols are used on the label on the LINAK products 00009 gt APPROVAL V94265 APPROVAL NO 97122 BAUART GEPRUFT Type B equipment as per EN60601 1 Protection against contact foreign matter first character and water second character as per EN60529 Class 2
18. ithout supervision Young children should be supervised to ensure that they do not play with the ud appliance T The LINAK products cannot tolerate the influence of strong solvents basic or alkaline liquids Residual risk A Some of the products contains software based components LINAK has done various possible efforts to assure that the software is free of errors and that the software has been developed according to the rules of IEC 60601 1 4 software in Medical products That involves Risk Analysis which shows a small residual risk for unwanted unintended movement of actuators under specific conditions According to the above rules it must be informed and if necessary considered in the Risk analysis of the final application More details to residual risk can be provided by LINAK if necessary Warning The plastic parts in the system cannot tolerate cutting oil Warning LINAK s actuators and electronics are not constructed for use within the following fields Planes and other aircrafts Explosive environments Nuclear power generation Warning If faults are observed the products must be replaced Before start up Make sure that the system has been installed as instructed in the User Manual Make sure that the voltage of the control box is correct before the system is connected to the mains System connection The individual parts must be connected before the control box is connected to the mains Du
19. lease contact LINAK 3 LINAK A S reserve the right to make technical alterations Copyright LINAK 2010 10 MA M9 02 345 WE IMPROVE YOUR LIFE
20. n releasing the emergency stop button the system is ready for use without any need to reset Connections for up to 2 actuators for main lift and leg spreader General description external charger option 2 If the control box has internal charger the mentioned diodes will appear on the control box instead Green light ON indicates mains power is ON Yellow light ON_ indicates battery is charging Optional cable hook The charger is either mounted between the control box and the battery on the patient lift or mounted separately on the wall or elsewhere When the charger is mounted between the control box and the battery the control box functions are disabled when mains power is supplied to the charger The charger is of the SMPS Switch Mode Power Supply type input voltage 100 240V AC Charging time max 4 hours for battery pack BAJ1 BAJ2 Exchangeable mains cable with locking ring Green light ON indicates the charger is connected to the mains power Yellow light ON indicates the battery is charging light OFF indicates battery fully charged Cable hook for storing the mains cable when the charger 15 not in use option Easy mounting of the charger on the JUMBO mounting brackets General description batteries BAJ2 DC plug for CHO1 external charger By means of a snap in system the battery pack can easily be mounted on th
21. nes Choose number of Choose number of cycles months between sevice a EN 9 service wo poo wen peoo Press this button if no months Press this button if no cycles are wanted as service interval J wa pam Lo wanted as service interval HD80 is another Hand control option for CBJ Care The diodes on HD80 have the same conditions for illumination as the CBJ Care please see the functionality paragraph Yellow diode at overload blinks if overload occurs Mounting of CBJ Care UP DOWN Mus CBJ Care has to be mounted vertically to ensure the IP protection 20 Mounting brackets available MBJ3 CHJ BAJ MBJ2 MBJ1 si E 2 5 8 E a E 21 Drawing 95 5 LINAK CBJ001B 158 137 22 Repairs In order to avoid the risk of malfunction all repairs must only be carried out by authorised LINAK workshops or repairers as special tools must be used and special gaskets must be fitted Products under warranty must also be returned to authorised LINAK workshops Warning A If any of the LINAK products are opened there will be a risk of subse
22. quent malfunction Warranty and service life The LINAK warranty covers manufacturing defects in the products starting from the date of manufacture There is 18 months for MEDLINE and CARELINE products The warranty is limited to the value of the LINAK product There is 12 months warranty for batteries from date of production covering manufacturing defect LINAK s guarantee is only valid so far as the products have been used and maintained correctly and has not been tampered with Furthermore the products must not be exposed to violent treatment In the event of this the warranty will be ineffective invalid LINAK s warranty is only valid if the system is unopened and has been used correctly All LINAK products are designed to have an optimum service life as a matter of course but the expected service life in a specific application is very dependent on how the products are used Disposal of LINAK s products LINAK s products may be disposed of possibly by dividing them into different waste groups for recycling or combustion We recommend that our product is disassembled as much as possible at the disposal and that you try to recycle it As an example of main groups within sorting of waste we can mention the following Metal plastic cable scrap combustible material and collection for recoverable resources Some of these main groups can be sub divided into groups e g metal can be divided into iron stainless steel and
23. ring operation Ensure that the cables are not damaged Unplug the mains cable on mobile equipment before it is moved Maintenance The LINAK products must be cleaned at regular intervals to remove dust and dirt and inspected for mechanical damage wear and breaks e The LINAK CBJ s are closed units and require no internal maintenance e Electronics must be inspected at attachment points wires cabinet and plugs Inspect the connections cables cabinet and plugs and check for correct functioning LINAK WE IMPROVE YOUR LIFE DECLARATION OF INCORPORATION OF PARTLY COMPLETED MACHINERY LINAK A S Smedevaenget 8 DK 6430 Nordborg Name and address of the person authorized to compile the relevant technical documentation John Kling Group Headquarters Guderup DK 6430 Nordborg email jkI linak com Herewith declares that LINAK Actuators and Actuator Systems comply with the following parts of the Machinery Directive 2006 42 EC ANNEX I Essential health and safety requirements relating to the design and construction of machinery 1 5 1 Electricity supply Directive 2006 95 EC on the harmonization of the laws of Member States relating to electrical equipment designed for use within certain voltage limits 1 5 10 Radiation 1 5 11 External radiation Directive 2004 108 EC on the approximation of the laws of the Member States relating to electromagnetic compatibility The relevant technical documentation is compiled in accordance
24. with part B of Annex VII and that this documentation or part hereof will be transmitted by post or electronically to a reasoned request by the national authorities This partly completed machinery must not be put into service until the final machinery into which it is to be incorporated has been declared in conformity with the provisions of this Directive where appropriate Date 2010 01 01 Signature John Kling Certification and Regulatory Affairs IP Protection degree All LINAK products can be cleaned as followed according to their IP protection which is stated on the product label IP Protection Cleaning instrucions IPX4 Clean with a damp cloth X can have a value of between 1 and 6 The materials are resistant to the majority of cleaners and disinfectants used in the hospital and nursing home sector Cleaning with a steam cleaner for example is not permitted as it will not be possible to maintain a minimum distance of 300 mm from the electrical parts When cleaning note that e The handset and motor plug must be pushed right in The water temperature must not exceed 65 C Cooling with cold water is not permitted The following directions regarding cleaners and disinfectants must be complied with They must not be highly alkaline or acidic pH value 6 8 They must not contain caustic agents Their contents must not be able to change the structure of the surface or adhesion of the plast
25. y and service life Disposal of LINAK s products Declaration of conformity LINAK application policy Addresses Preface We are delighted that you have chosen a product from LINAK LINAK systems are high tech products based on many years of experience in the manufacture and development of actuators electric control boxes controls and chargers This User Manual will tell you how to install use and maintain your CBJ Care We are sure that your LINAK system will give you many years of problem free operation Before our products leave the factory they undergo full function and quality testing Should you nevertheless experience problems with your systems you are always welcome to contact your local dealer LINAK subsidiaries and some distributors situated all over the world have authorized service centres which are always ready to help you LINAK provides a warranty on all its products This warranty however is subject to correct use in accordance with the specifications maintenance being done correctly and any repairs being carried out at a service centre which is authorized to repair LINAK products Changes in installation and use of LINAK systems can affect their operation and durability The products are not to be opened by unauthorized personnel The User Manual has been written on the basis of our present technical knowledge We are constantly working on updating the information
Download Pdf Manuals