Home

Hot Cupboard Instruction Manual

image

Contents

1. Lincat Installation Operating and Servicing Instructions Panther Hot Cupboards P6B2 P6B3 P6B4 P6B5 P6P2 P6P3 P6P4 P6P5 P8B3 P8B3PT P8B4 P8B4PT P8B5 P8B5PT P8B6 P8B6PT P8P3 P8P3PT P8P4 P8P4PT P8P5 P8P5PT P8P6 P8P6PT Please make a note of your product details for future use Date Purchased Model Number Serial Number Dealer PANTHER IS 464 ECN 3459 Page 1 of 13 CONTENTS Important Information Warnings and Precautions Technical Data aN Installation and Commissioning Operating Instructions Cleaning Servicing Maintenance and Component Replacement 2 3 3 Checklist of Enclosures 4 4 7 9 1 Fault Finding 10 Spare Parts List 11 12 Accessories 12 Service Information and Guarantee 13 NOTE OP p IS 464 IMPORTANT INFORMATION Read these instructions carefully before using this product paying particular attention to all sections that carry warning symbols caution symbols and notices Ensure that these are understood at all times WARNING This symbol is used whenever there is a risk of personal injury CAUTION This symbol is used whenever there is a risk of damaging your Lincat product NOTE This symbol is used to provide additional information hints and tips KEEP THIS MANUAL FOR FUTURE REFERENCE ECN 3459 Page 2 of 13 A WARNINGS AND PRECAUTIONS This appliance must be installed commissioned and
2. NOTE A Set button B Digital readout C Adjust D Adjust E Element On symbol The electronic controller for the cupboard has a range of 20 Deg C to 99 Deg C and is factory set at 85 Deg C On switching the unit on the digital readout B displays the current temperature within the cupboard Pressing the Set button A once displays the temperature the cupboard is currently set to reach To adjust this temperature hold down the Set button for 3 seconds and then set the required temperature by using the adjust buttons C and D on the controller The digital readout then returns to show the current temperature Pre heat the cupboard the element symbol E is extinguished when the required temperature is reached Load the cupboard with heated food as required The desired heat settings will be found with practice and will depend on the amount and temperature of the food in the unit and the frequency of opening of the doors Check food temperature regularly Do not disconnect the cupboard from the supply until it is ready to be moved to the distribution point Re connect as soon as the distribution point is reached Operation of gantries selected models is via the switch on the control panel PG6 units or the gantry overshelf PS8 units To turn the unit off switch off at the mains socket and ensure the green light has gone out A small bowl of water placed on the bottom shelf once t
3. 21 5 P8B4PT 2 45 2 5 4 95 21 5 P8B5 2 7 2 5 5 2 22 6 P8B5PT 2 7 2 5 5 2 22 6 P8B6 2 7 2 5 5 2 22 6 P8B6PT 2 7 2 5 5 2 22 6 P8P3 N A 1 5 1 5 6 5 P8P3PT N A 1 5 1 5 6 5 P8P4 N A 2 5 2 5 10 9 P8P4PT N A 2 5 2 5 10 9 P8P5 N A 2 5 2 5 10 9 P8P5PT N A 2 5 2 5 10 9 P8P6 N A 2 5 2 5 10 9 P8P6PT N A 2 5 2 5 10 9 Connecting to supply P6 models may be connected to the electrical supply by means of the fitted plug and lead For P8 models connect as below referring to Fig 1 The electrical inlet box is fitted to the base using a hook A and slot B method Access the box from the side and remove 2 screws C Pull the box towards you D disengaging the hooks Lower the box E to access the terminal block Disconnect and discard the attached test cables and connect the unit to a suitable supply cable Refit the box ensuring no wires are trapped IS 464 ECN 3459 Page 5 of 13 Fig 1 IS 464 ECN 3459 Page 6 of 13 ACCESS BOX FROM SIDE To fit push bar handle using allen keys provided remove bolts A and discard Fit handle using bolts provided in handle kit Fig 2 OPERATING INSTRUCTIONS Only qualified or trained personnel should use this appliance Ensuring doors are closed switch on the power at the mains supply The green neon illuminates to indicate power to the appliance Electronic controller Fig 3 IS 464 ECN 3459 Page 7 of 13
4. ENCLOSURES Warranty Card Instructions Manual Shelves combinations to make 2 rows Push bar handle kit Gastronorm dividers Bains Marie units only Drain tube Bains Marie units only F INSTALLATION AND COMMISSIONING This appliance must be earthed An equipotential bonding terminal is provided to allow cross bonding with other equipment If replacing the plug connect the terminals as follows Green and Yellow wire Earth E Blue wire Neutral N Brown wire Live L Means of isolation with at least 3mm contact separation in all poles must be incorporated into the fixed wiring of this appliance The fixed wiring insulation must be protected by insulated sleeving having a temperature rating of 60 Deg C Supply cords shall be oil resistant sheathed flexible cable not lighter than ordinary polychloroprene or equivalent elastomer sheathed cord code 60245 IEC 57 Install this appliance on a level surface ensuring all vents are unobstructed IS 464 ECN 3459 Page 4 of 13 Power Ratings Bains Marie Cupboard Current A Model aes aa Total kW Ba ne P6B2 1 1 1 5 2 6 11 3 P6B3 1 35 1 5 2 85 12 4 P6B4 2 45 2 5 4 95 21 5 P6B5 2 7 2 5 5 2 22 6 P6P2 N A 1 5 1 5 6 5 P6P3 N A 1 5 1 5 6 5 P6P4 N A 2 5 2 5 10 9 P6P5 N A 2 5 2 5 10 9 P8B3 1 35 1 5 2 85 12 4 P8B3PT 1 35 1 5 2 85 12 4 P8B4 2 45 2 5 4 95
5. P6B4 P6B5 P6P3 P6P4 P6P5 P8B3 P8B3PT P8B4 P8B4PT P8B5 P8B5PT P8B6 P8B6PT P8P3 P8P3PT P8P4 P8P4PT P8P5 P8P5PT P8P6 P8P6PT SH122 Shelf 324mm P6B3 P6B5 P6P3 P6P5 P8B3 P8B3PT P8B5 P8B5PT P8P5 P8P5PT SH125 Shelf 788mm P6B2 P6P2 TE40 Terminal block 3 way P6B2 P6B3 P6P2 P6P3 P6P4 P6P5 P8B3 P8B3PT P8P3 P8P3PT TE47 Terminal block 7 way P6B3 P6B4 P6B5 P8B3 P8B3PT P8B4 P8B4PT P8B5 P8B5PT P8B6 P8B6PT P8P3 P8P3PT P8P4 P8P4PT P8P5 P8P5PT P8P6 P8P6PT TH34 Thermostat Bains Marie All Bains Marie models TUO1 Silicone rubber tube All Bains Marie models VA19 Drain valve All Bains Marie models IS 464 ECN 3459 Page 11 of 13 Spare Parts for gantries Part Number Part Description Used on GL517 Sneeze screen 885mm PG62A PG62H GL518 Sneeze screen 1110mm PG63A PG63H GL519 Sneeze screen 1435mm PG64A PG64H GL520 Sneeze screen 1760mm PG65A PG65H IN42 Plain insert All PS8 models IN82 Ribbed insert PG64A PG64H PG65A PG65H LA211 Clip in lamp holder All PS8 heated models LA324 200W Heat lamp All PG6 heated models All PS8 heated models LA325 Lamp holder PG62H PG63H PG64H PG65H LA326 Reflector for lamp PG62H PG63H PG64H PG65H LE14 Lens cover for switch All PS8 heated models SW34 Switch All PS8 heated models TE02 Terminal block ceramic All PG6 heated models All PS8 heated models Sp
6. are parts for Accessories Part Number Part Description Used on BU62 Bush tray slide EC03 End cap tray slide EC08 End cap push bar All HA105 Handle door lock LO24 Door lock ACCESSORIES Part Number Part Description Used on PTS2 3 4 5 Drop down tray slides All order width to suit PDL Door lock All PPB6 Additional push bar handle 670 models PPB8 Additional push bar handle 800 models CP16 Carvery pad PHTC Ceramic hot tile All PHTG Glass hot tile factory fitted IS 464 ECN 3459 Page 12 of 13 SERVICE INFORMATION AUTHORISED SERVICE AGENTS Catering equipment should be routinely serviced to ensure a long trouble free life We recommend that this appliance is serviced every 6 months by a competent engineer All service work other than routine cleaning should be carried out by one of our authorised service agents We cannot accept responsibility for work carried out by other persons For help regarding the installation maintenance and use of your Lincat equipment please call LINCAT SERVICE HELP DESK 44 0 1522 875520 Please quote both the model and serial numbers from the data plate attached to the unit Give brief details of the service requirement and if possible the product codes of any spare parts you require Work carried out under warranty will normally be undertaken during normal working hours i e Mond
7. ay to Friday 8 30 a m 5 00 p m CONDITIONS OF GUARANTEE The guarantee does not cover 1 Accidental breakage or damage 2 Operational misuse wear and tear from normal usage incorrect adjustment or neglect 3 Incorrect installation maintenance modification or unauthorised service work IS 464 ECN 3459 Page 13 of 13
8. he appliance is stationary will help prevent food drying out Additional instructions for Models with Bains Marie tops Bains Marie may be used either dry or wet best results are obtained when used wet Temperature is controlled via 1 6 settings on the control knob For dry heat ensure gastronorm dishes are in place then allow unit to heat up for 20 minutes on full before filling with hot food To use wet fill the tank up to the high level mark with hot water 40 Deg C With gastronorm dishes in place allow a further 60 minutes on full for the water to reach optimum heat before filling with hot food Maintain the water level above the minimum mark With the appliance turned off after use allow the water to cool and using the drain tube provided regularly empty the water well via the valve inside the cupboard Clean out the tank and refill with fresh water IS 464 ECN 3459 Page 8 of 13 Operation of tray slide Selected models only 1 Lift up 2 Rotate down Fig 4 CLEANING VAS Do not use a water jet or steam cleaner and do not immerse this appliance Clean all panels with warm water and mild detergent do not use abrasive materials Dry with a soft cloth IS 464 ECN 3459 Page 9 of 13 To access the inside of the cupboard for cleaning remove the doors as shown below Fig 5 1 Lift door up in to top guide 2 Rotate door bottom to lift clear of bottom guide Reve
9. rse procedure to refit Clean the door sliders to ensure smooth operation of the doors SERVICING MAINTENANCE AND COMPONENT REPLACEMENT All servicing maintenance and component replacement on these appliances should be carried out by one of our recommended service engineers FAULT FINDING Please refer to the Service Helpdesk number on the final page of this manual IS 464 ECN 3459 Page 10 of 13 SPARE PARTS LIST Spare Parts for cupboards Part Number Part Description Used on CA150 Castor All DS29 Door slide All EC04 Handle end cap All EC16 Electronic controller All EL177 Bains Marie element 1 1kW P6B2 P6B4 short P8B4 short P8B4PT short EL232 Cupboard element 2 5kW P6B4 P6B5 P6P4 P6P5 P8B4 P8B4PT P8B5 P8B5PT P8B6 P8B6PT P8P4 P8P4PT P8P5 P8P5PT P8P6 P8P6PT EL236 Cupboard element 1 5kW P6B2 P6B3 P6P2 P6P3 P8B3 P8B3PT P8P3 P8P3PT EL279 Bains Marie element 1 35kW P6B3 P6B4 long P6B5 P8B3 P8B3PT P8B4 long P8B4PT long P8B5 P8B5PT P8B6 P8B6PT FA106 Cupboard fan All FA120 Cooling Fan controller All Bains Marie models HA105 Handle All KN203 Control Knob All Bains Marie models NE38 Green neon All PL157 Plug amp lead P6B2 P6B3 P6P2 P6P3 SB05 Gastronorm divider 534mm All Bains Marie models SB06 Gastronorm divider 327mm All Bains Marie models SH119 Shelf 643mm P6B3
10. serviced by a qualified person in accordance with national and local regulations in force in the country of installation If the supply cord is damaged it must be replaced by the manufacturer its service agent or similarly qualified person Ensure that the plug socket is accessible at all times Strip plastic coating and clean the appliance before use During operation parts may become hot avoid accidental contact Disconnect this appliance before servicing maintenance or cleaning TECHNICAL DATA Codes Explained P 6 or 8 BorP 2 3 4 50r6 PT Panther Unit Depth Bain Marie or Number of Pass Through Plain top 1 1 Gastronorms model Model Height mm Width mm Depth mm Weight kg P6B2 900 80 P6B3 1125 95 P6B4 1450 116 P6B5 1775 136 P6P2 900 670 71 P6P3 1125 86 P6P4 1450 105 P6P5 1775 124 P8B3 900 1125 104 P8B3PT 1125 106 P8B4 1450 125 P8B4PT 1450 127 P8B5 1775 800 146 P8B5PT 1775 148 P8B6 2100 166 P8B6PT 2100 168 P8P3 1125 92 P8P3PT 1125 94 IS 464 ECN 3459 Page 3 of 13 Model Height mm Width mm Depth mm Weight kg P8P4 1450 114 P8P4PT 1450 116 P8P5 1775 136 P8P5PT a 1775 890 138 P8P6 2100 158 P8P6PT 2100 160 CHECK LIST OF