1. Service Pack Release Letter Security Systems MIC 550 SC Main 2 14 00 08 Table of Contents BOSCH MIC Series 550 Version 01 00 1 Introduction 2 1 1 Disclaimer of Warranty 2 1 2 Purpose 2 1 3 Scope 2 2 About This Service Pack Release 2 3 Hardware Changes 2 4 Software Changes 3 4 1 Remapping Aux Commands Pelco Protocol 3 4 2 Enhancements 3 4 3 Defects Resolved 3 5 Feature Restrictions 3 6 Uploading Firmware 3 7 History 4 Release Notes 01 00 Last 2012 Checked In _ Jan 25 Robert Bosch GmbH reserves all rights even in the event of industrial property rights We reserve all rights of disposal such as copying and passing on to third parties Security Systems Service Pack Release Letter BOSCH MIC Series 550 MIC 550 SC Main 2 14 00 08 Service Pack Release Letter 1 Introduction 1 1 Disclaimer of Warranty Version 01 00 Date 20 Nov 2012 Page 2 of 5 Bosch Security Systems Inc makes no representations or warranties either expressed or implied by or with respect to anything in this document and shall not be liable for any implied warranties of merchantability or fitness for a particular purpose or for any indirect special or consequential damages 1 2 Purpose The purpose of the Service Pack Release Letter document is to communicate major new features and changes in this release of the MIC Series 550 product It also docume
2. in the event of industrial property rights We reserve all rights of disposal such as copying and passing on to third parties Security Systems BOSCH 7 History Service Pack Release Letter MIC Series 550 MIC 550 SC Main 2 14 00 08 The following files have been updated in past Service Pack releases Version 01 00 Date 20 Nov 2012 Page 4 of 5 Component Version MIC550Main G4i 2 14 00 08 MIC500Main G4i 2 12 00 07 MICMain G4i 2 02 00 38 MICMain G4i 2 10 00 04 The following ENHANCEMENTS have been implemented in past Service Pack releases Change Request Description Service Pack IMC00004626 Added Pelco Wiper Only function to Aux Re mapping MIC550Main G4i command list IMC00004657 Improved control when a MIC 550 using ForwardVision MIC550Main G4i protocol is connected to a Synectics system IMC00003589 Implemented special preset commands for Forward Vision MIC550Main G4i protocol IMC0004327 Changed default settings for White Balance and Sharpness MIC550Main G4i IMC00003783 Update to FPGA code for PTZ control FPGA_MIC_SC_ Biphase_550 G4i IMC00004096 Improves sharpness on video image MIC550Main G4i IMC00003685 Users can now remap Pelco Auxiliary commands through 8 MIC550Main G4i This enhancement adds the Aux Setup submenu below the Competitive Protocol menu IMC00004095 Support for enhanced noise
3. property rights We reserve all rights of disposal such as copying and passing on to third parties Security Systems BOSCH Service Pack Release Letter Version 01 00 Date 20 Nov 2012 MIC Series 550 Page 5 of 5 MIC 550 SC Main 2 14 00 08 IMC00003219 FV Add ability to use Bosch camera menu MICMain G4i IMC00002432 FV Implement H command Get Manual Control and MICMain G4i Alarm Status IMC00002447 FV Implement command Get MIC Statistics MICMain G4i The following DEFECTS have been resolved in past Service Pack releases Change Description Service Pack Request IMC00004783 Camera responds when an interactive Pan Tilt Zoom command is sent MIC550Main G4i IMC00004778 ForwardVision Night mode is operational MIC550Main G4i IMC00004847 Added One Push as a Focus mode stored on a preset MIC550Main G4i IMC00004545 Improved noise reduction MIC550Main G4i IMC00003842 Activated Input 8 as a valid input for Alarm Rules MIC550Main G4i IMC00002798 IMC00003903 Corrects issue with wash wipe behavior if the was position is not MIC550Main G4i predefined IMC00003772 Corrects issue with fast address using the Forward Vision protocol MIC550Main G4i IMC00002902 Improve Bicom Commands MICMain G4i IMC00002983 Alarm Menus Restore Defaults option no longer restores defaults for MICMain G4i whole devi
4. ce IMC00002567 Improve Data migration of privacy masks via Bilinx MICMain G4i IMC00003058 Scene departed event was not firing for wash wipe MICMain G4i IMC00003034 Alarm gt Alarm Rules gt Output Option Transmit gt Output period MICMain G4i would not activate IMC00003237 Alarm Output Options gt Type None cannot be set again when another MICMain G4i Type was set before IMC00002919 Some of the alarm options could not be uploaded to CTFID MICMain G4i IMC00003094 Adjust night mode threshold default value MICMain G4i IMC00003074 Incorrect Alarm Output type provided to CTFID MICMain G4i IMC00003052 Switching between Bosch and FV protocols improved MICMain G4i IMC00003359 Prevent False Motion Alarms if Wiper Washer is started MICMain G4i IMC00003342 FV N command Sending max pan at max pan position caused 360 MICMain G4i degree pan IMC00003373 FV Modify the speed conversion algorithm in G command MICMain G4i IMC00003447 False Alarms were triggered When Alarm Input state is selected as N C MICMain G4i as default state IMC00003398 Scene 1 Inactivity did not work after pan tilt moving MICMain G4i IMC00003235 Alarm Rules could only be executed once MICMain G4i IMC00003559 Wash wipe now functional in FV protocol MICMain G4i IMC00003123 Pelco D Above the horizon tilt positions now points to the upper tilt MICMain G4i limit Robert Bosch GmbH reserves all rights even in the event of indu
5. nts component compatibility workarounds and any feature restrictions 1 3 Scope This document describes the MIC Series 550 Service Pack Release which includes the following components Component Version MIC550Main G4i 2 14 00 08 2 About This Service Pack Release e This is an Engineering Release of the firmware components identified section 1 3 3 Hardware Changes None Robert Bosch GmbH reserves all rights even in the event of industrial property rights We reserve all rights of disposal such as copying and passing on to third parties Security Systems BOSCH Service Pack Release Letter MIC Series 550 MIC 550 SC Main 2 14 00 08 4 Software Changes This section identifies enhancements and defect resolutions provided in the current Service Pack for the MIC Series 550 4 1 Remapping Aux Commands Pelco Protocol This service pack adds the Wiper Only function to the list of Pelco commands that can be remapped to a specific Aux number Refer section 9 8 in the MIC Series 550 Camera User Manual for more information Version 01 00 Date 20 Nov 2012 Page 3 of 5 4 2 Enhancements The following ENHANCEMENTS have been resolved for this delivery Change Description Module Request IIMC00005425 Add wiper delay feature to washer function MIC550Main G4i IMC00005156 Add menu option to access the On screen Display menus
6. reduction This enhancement adds MIC550Main G4i the following items to the Camera menu Noise Reduction and Noise Reduction Level IMC00002404 Support Forward Vision FV protocol MICMain G4i IMC00002434 FV Implement L command Go To Preset MICMain G4i IMC00002440 FV Implement W command Reset MICMain G4i IMC00002892 Send Bicom events to the OSRD serial port MICMain G4i IMC00002893 Add Bicom Event for Wiper operation MICMain G4i IMC00002435 FV Implement M command Learn Preset Normal presets MICMain G4i only IMC0000243 1 FV Implement G command Set Manual Control MICMain G4i IMC00002445 FV Implement w command Set Manual Control with MICMain G4i Proportional Zoom IMC00002444 FV Implement s command Set Address MICMain G4i IMC00002438 FV Implement R command Setup Preset Tour MICMain G4i IMC00002439 FV Implement T command Start Stop Preset Tour MICMain G4i IMC00003088 Pelco D Query Type command now provides response MICMain G4i message IMC00002436 FV Implement N command Go To Position MICMain G4i IMC00002437 FV Implement O command Get Position MICMain G4i IMC00002442 FV Implement a command Get Config MICMain G4i IMC00002443 FV Implement q command Set Config MICMain G4i IMC00002433 FV Implement K command Emergency Stop MICMain G4i IMC00002441 FV Implement Y command Get Software Version MICMain G4i Robert Bosch GmbH reserves all rights even in the event of industrial
7. strial property rights We reserve all rights of disposal such as copying and passing on to third parties
8. when using MIC550Main G4i Pelco D IMC00005483 Extended address range from 32 to 255 when using Pelco P MIC550Main G4i 4 3 Defects Resolved The following DEFECTS have been resolved for this delivery Change Description Module Request IMC00003743 The wash wipe function now completes the cycle if Inactivity is turned MIC550Main G4i on IMC00005157 Changed absolute positioning commands to 0 1 degree resolution MIC550Main G4i IMC00005383 direction of absolute position movements when changing between Normal and Inverted operation IMC00004495 The camera returns to its last position when power is disconnected after a MIC550Main G4i wash wipe cycle then reconnected IMC00004496 The camera returns to its last position when the wash wipe cycle is MIC550Main G4i IMC00004442 terminated by a user initiated command IMC00004585 Playback of a recording made via the Forward Vision protocol now MIC550Main G4i contains zoom actions IMC00004441 Camera returns to preset scene after the completion of the wash wipe MIC550Main G4i cycle IMC00004442 The wiper stops if the user interrupts the Wash cycle MIC550Main G4i IMC00005302 Can toggle the IR lamps on off from Camset or the Synectics keyboard MIC550Main G4i 5 Feature Restrictions None 6 Uploading Firmware Refer to the AutoDome 100 600 700 800 and MIC 550 Firmware Update Manual available on the Bosch Security Systems Web site Robert Bosch GmbH reserves all rights even