CP-RIO6-923-F User Manual

image

Contents

1. 14 iv CP RI06 923 F User Guide www kontron com List of Figures Figure 3 1 CP RIO6 923 F Front Panel 15 Figure 3 2 CP RIO6 923 F12 Front 15 Fe FI 15 v CP RI06 923 F User Guide www kontron com Preface Proprietary Note This document contains information proprietary to Kontron AG It may not be copied or transmitted by any means disclosed to others or stored in any retrieval system or media without the prior written consent of Kontron AG or one of its authorized agents The information contained in this document is to the best of our knowledge entirely correct However Kon tron AG cannot accept liability for any inaccuracies or the consequences thereof or for any liability arising from the use or application of any circuit product or example shown in this document Kontron AG reserves the right to change modify or improve this document or the product described herein as seen fit by Kontron AG without further notice Trademarks Kontron AG and the Kontron logo are trade marks owned by Kontron AG Germany In addition this document may include names company logos and trademarks which are registered trademarks and therefore propri etary to their respective owners Environmental Protection Statement This product has been manufactured to satisfy environmental protection requirements where possible Many of the
2. www kontron com 14 CP RI06 923 F User Guide Hardware Description 3 4 Air Baffle The CP RI06 923 F12 variant has an air baffle along the lower edge of the board This significantly reduces air flow across the board thus improving air flow on other boards in the system WARNING Be careful when handling the CP RI06 923 F12 The air baffle has A sharp edges which might lead to injuries 3 5 Front Panel Elements Figure 3 1 CP RI06 923 F Front Panel a O O 3 Figure 3 2 CP RI06 923 F12 Front Panel Figure 3 3 CP RI06 923 F 8M12 Front Panel 15 CP RI06 923 F User Guide www kontron com Appendix A Getting Help www kontron com A Getting Help If at any time you encounter difficulties with your application or with any of our products or if you simply need guidance on system setups and capabilities contact our Technical Support at North America EMEA Tel 450 437 5682 Tel 49 0 8341 803 333 Fax 450 437 8053 Fax 49 0 8341 803 339 If you have any questions about Kontron our products or services visit our Web site at www kontron com You also can contact us by E mail at North America support ca kontron com EMEA support kom kontron com Or at the following address North America EMEA Kontron Canada Inc Kontron Modular Computers GmbH 4555 Ambroise Lafortune Sudetenstrasse 7 Boisbriand Qu bec 87600
3. 2 12 Technical TN Ge 3 2 Installation 2 41 S jety Re uirements 5 2 2 Installation 6 E EAEE EEEN 7 2 Hardware Description savne 3 1 RI451000BASE TPO NS ciccia 9 3 2 M12 100BASE TX Ports rire re re reo 10 3 3 COMPAR BUS LOMNCELONS NEEE 11 ALI 15 3 5 Front Panel 15 A Getting AL A 1 Returning 5 A 2 A2 When Retuming A 3 iii CP RI06 923 User Guide www kontron com List of Tables Table 1 1 CP RIO6 923 F Main Specifications srl ee 3 Table 3 1 Ethernet NNN 9 T ble 3 2 RJ45 ila 10 DET Eth rnet Port Mapping ee 10 Table 3 4 M12 D coded female Connector Pin Assignment ieri 11 Table 3 5 J3 Connector Pin Assignment siii 12 Table 3 6 J4 Connector Pin 13 Table 3 7 J5 Connector Pin Assignment
4. Before any installation or setup ensure that the board is unplugged from power sources or subsystems If you encounter a problem verify the following items e Make sure that all connectors are properly connected e Verify your boot devices e Ifthe system does not start properly try booting without any other 1 0 peripherals attached including AMC adapters xi CP RI06 923 F User Guide www kontron com Preface Make sure your system provides the minimum DC voltages required at the board s slot especially if DC power is carried by cables If you are still not able to get your board running contact our Technical Support for assistance Storing the Boards Electronic boards are sensitive devices Do not handle or store device near strong electrostatic electromag netic magnetic or radioactive fields General Instructions on Usage In order to maintain Kontron s product warranty this product must not be altered or modified in any way Changes or modifications to the device which are not explicitly approved by Kontron AG and described in this manual or received from Kontron s Technical Support as a special handling instruction will void your warranty This device should only be installed in or connected to systems that fulfill all necessary technical and spe cific environmental requirements This applies also to the operational temperature range of the specific board version which must not be exceeded If batteries
5. ations and inspections of this product in order to ensure product integrity at all times Unpacking Follow these recommendations while unpacking Remove all items from the box If any items listed on the purchase order are missing notify Kontron customer service immediately e Inspect the product for damage If there is damage notify Kontron customer service immediately e Keep all the original packaging material for future storage or warranty shipments If it is necessary to store or ship the board please re pack it as nearly as possible in the manner in which it was delivered Do not handle this product out of its protective enclosure while it is not used for operational purposes unless it is otherwise protected Whenever possible unpack or pack this product only at EOS ESD safe work stations Where a safe work sta tion is not guaranteed it is important for the user to be electrically discharged before touching the product with his her hands or tools This is most easily done by touching a metal part of your system housing It is particularly important to observe standard anti static precautions when changing mezzanines ROM devices jumper settings etc If the product contains batteries for RTC or memory back up ensure that the board is not placed on conductive surfaces including anti static plastics or sponges They can cause short circuits and damage the batteries or conductive circuits on the board Powering up the System
6. e Non Operating 5 95 non condensing at 40 C 104 F Designed to meet or exceed the following Altitude e Operating 4000 m 13123ft e Non operating 15000 m 49212 ft Designed to meet or exceed the following e Bellcore GR 63 Section 4 4 e Operating 2gRMS 1 00 5 500Hz each axis e Non operating 0 5G 5 50Hz 3 00 50 500Hz each axis Designed to meet or exceed the following e DIN IEC 60068 2 27 e MIL STD 810E Method 516 30G half sine 11ms each axis Humidity Vibration Shock Designed to meet or exceed the following Safety e UL60950 1 e 60950 Designed to meet or exceed the following e FCC 47 CFR Part 15 Subpart B e EN55022 EN55024 e 300 386 MTBF according to Bellcore Issue 6 Ground Benign 40 C is e CP RI06 923 F gt 2 621 000 hours e CP RI06 923 F12 gt 2 431 000 hours e CP RI06 923 F 8M12 gt 2 397 000 hours EMC Reliability 3 CP RI06 923 F User Guide www kontron com Chapter 2 Installation www kontron com Installation 2 Installation The CP RI06 923 F has been designed for easy installation However the following standard precautions installation procedures and general information must be observed to ensure proper installation and to pre clude damage to the board other system components or injury to personnel 2 1 Safety Requirements The following safety precautions must be observed when installing or operating the CP RI06 923 F Kontron assume
7. to Kontron Customers may reprint and use this user s guide in other publications Customers may alter this user s guide and publish it only after they remove the Kon tron name cover and logo Kontron reserves the right to make changes without notice in product or component design as warranted by evolution in user needs or progress in engineering or manufacturing technology Changes that affect the operation of the unit will be documented in the next revision of this user s guide ii CP RI06 923 F User Guide www kontron com Table of Contents REVISION History e ii Customer Sem mauriske ara i Proprietary vi Trademarks vi Environmental Protection Statement L rire vi Before YOU dei eredi vii When Working Inside a Computer rrnnornnnorvnnnrrnnnvrnnnnvnnnnennnnernnnernnnnernnvennneevnnesennesennnevennesennneee viti Advisory ea IX cote nie Special Handling and Unpacking Instructions rire xi General Instructions On Usage slo aa ala xii Regulatory Compliance Statements xiii TWO E EEE N E a xiv i Introduction PRE sec
8. 12 12x FL 13 13x FL 14 14x FL_15 15x FL_16 16x FL_17 17x FL_18 18x FL_19 19x The RJ45 connectors are not equipped with LEDs for displaying the link status or activity These are on the switch board front panel 10 CP RI06 923 F User Guide www kontron com Hardware Description The table below shows the pin assignment of one M12 D coded female connector Table 3 4 M12 D coded Female Connector Pin Assignment Pin Signal Industrial Ethernet M12 il TD 2 RD 2 3 TD a Se 1 0 3 Housing Shield 4 3 3 CompactPCI Bus Connectors Three daughter card connecters rJ3 rJ4 and rJ5 are used for the connection between the CP RI06 923 F and the backplane e rJ3 connects FL Port 1 to FL Port 8 and FL Port f e rJ4 connects FL Port 20 to FL Port 23 e rJ5 connects FL Port 9 to FL Port 19 Connector rJ3 is not implemented on the CP RI06 923 F 8M12 11 CP RI06 923 F User Guide www kontron com Hardware Description The cPCI connectors have the following pin assignment Table 3 5 13 Connector Pin Assignment le DN a eee 19 NC NC NC NC NC GND 18 FL DA24 f FL DA24 f GND FL DC24 f FL DC24 f GND 17 FL DB24 f FL DB24 f GND FL DD24 f FL DD24 f GND 16 FL DA8 FL DA8 GND FL DC8 FL DC8 GND 15 FL DB8 FL DB8 GND FL DD8 FL DD8 GND 14 FL DA7 FL DA7 GND FL DC7 FL DC7 GND 13 FL DB7 FL DB7 GND FL DD7 FL DD7 GND 12 FL DA6 FL 6 GND FL DC6 FL DC6 GND 11 FL DB6 FL DB6 G
9. A 2 When Returning a Unit e Inthe box you must include the name and telephone number of a person in case further explana tions are required Where applicable always include all duty papers and invoice s associated with the item s in question e Ensure that the unitis properly packed Pack itin a rigid cardboard box e Clearly write or mark the RMA number on the outside of the package you are returning e Ship prepaid We take care of insuring incoming units North America EMEA Kontron Canada Inc Kontron Modular Computers GmbH 4555 Ambroise Lafortune Sudetenstrasse 7 Boisbriand Qu bec 87600 Kaufbeuren J7H 0A4 Canada Germany A 3 CP RI06 923 F User Guide www kontron com
10. Advisory Conventions CAUTION This symbol and title indicate potential damage to hardware and tells you how to avoid the problem A CAUTION A Electric Shock A This symbol and title warn of hazards due to electrical shocks gt 60V when touching products or parts of them Failure to observe the pre cautions indicated and or prescribed by the law may endanger your life health and or result in damage to your material WARNING This symbol and title emphasize points which if not fully understood A and taken into consideration by the reader may endanger your health and or result in damage to your material A ESD Sensitive Device This symbol and title inform that electronic boards and their components are sen sitive to static electricity Therefore care must be taken during all handling oper ations and inspections of this product in order to ensure product integrity at all times Please read also the section Special Handling and Unpacking Instructions Note This symbol and title emphasize aspects the reader should read through carefully for his or her own advantage CE Conformity This symbol indicates that the product described in this manual is in compliance with all applied CE standards Please refer also to the section Regulatory cpmpli ance Statements in this manual ix CP RI06 923 F User Guide www kontron com Preface Safety Instructions Your new Kontron product wa
11. G kontron Kontron User s Guide CP RI06 923 F Document Revision 1 1 Document ID CP RI06 923 F Issue Date April 2011 9 9 9 Revision History 0 5 Initial Issue 29 09 2009 1 0 Frontplate drawing updated 01 10 2009 11 Minor changes in chapter 1 Section M12 100BASE TX Ports added in 27 04 2011 chapter 3 and other minor changes Customer Service Contact Information Kontron Canada Inc Kontron Modular Computer GmbH 4555 Ambroise Lafortune Sudetenstrasse 7 Boisbriand Qu bec Canada 87600 Kaufbeuren J7H 0A4 Germany Tel 450 437 5682 49 0 8341 803 333 800 354 4223 Fax 450 437 8053 49 0 8341 803 339 E mail support ca kontron com support kom kontron com Visit our site at www kontron com 2011 Kontron an International Corporation All rights reserved The information in this user s guide is provided for reference only Kontron does not assume any liability arising out of the application or use of the information or products described herein This user s guide may contain or reference information and products protected by copyrights or patents and does not convey any license under the patent rights of Kontron nor the rights of others Kontron is a registered trademark of Kontron All trademarks registered trademarks and trade names used in this user s guide are the property of their respective owners All rights reserved Printed in Canada This user s guide contains information proprietary
12. Kaufbeuren J7H 0A4 Canada Germany A 1 Returning Defective Merchandise Before returning any merchandise please do one of the following Call e Call our Technical Support department in North America at 450 437 5682 or in EMEA at 49 0 8341 803 333 Make sure you have the following on hand our Invoice your Purchase Order and the Serial Number of the defective unit e Provide the serial number found on the back of the unit and explain the nature of your problem to a service technician e The technician will instruct you on the return procedure if the problem cannot be solved over the telephone e Make sure you receive an RMA from our Technical Support before returning any merchandise A 2 CP RI06 923 F User Guide www kontron com e Fax e Send usa fax at North America 450 437 0304 EMEA 49 0 8341 803 339 In the fax you must include your name your company name your address your city your postal zip code your phone number and your e mail You must also include the serial number of the defective product and a de scription of the problem e E mail e Send us an e mail at RMA ca kontron com in North America or at orderprocessing kontron modular com in EMEA In the e mail you must include your name your company name your ad dress your city your postal zip code your phone number and your e mail You must also include the serial number of the defective product and a description of the problem
13. ND FL DD6 FL DD6 GND 10 FL DA5 FL DA5 GND FL DC5 FL DC5 GND 9 FL DB5 FL DB5 GND FL DD5 FL DD5 GND 8 FL DA4 FL DA4 GND FL DC4 FL DC4 GND 7 FL DB4 FL DB4 GND FL DD4 FL DD4 GND 6 FL DA3 FL DA3 GND FL DC3 FL DC3 GND 5 FL DB3 FL DB3 GND FL DD3 FL DD3 GND 4 FL DA2 FL DA2 GND FL DC2 FL DC2 GND 3 FL DB2 FL DB2 GND FL DD2 FL DD2 GND 2 FL_DA1 FL_DA1 GND FL_DC1 FL_DC1 GND 1 FL_DB1 FL_DB1 GND FL_DD1 FL_DD1 GND 12 CP RI06 923 F User Guide www kontron com Hardware Description Table 3 6 J4 Connector Pin Assignment PS ET LE ee MILA FL_DA20 FL_DA20 FL_DC20 FL_DC20 24 FL_DB20 FL_DB20 GND FL_DD20 FL_DD20 GND 23 FL_DA21 FL DA21 GND FL DC21 FL DC21 GND 22 FL DB21 FL DB21 GND FL DD21 FL DD21 GND 21 FL DA22 FL DA22 GND FL DC22 FL DC22 GND 20 FL DB22 FL DB22 GND FL DD22 FL DD22 GND 19 FL DA23 FL DA23 GND FL DC23 FL DC23 GND 18 FL DB23 FL DB23 GND FL DD23 FL DD23 GND 17 NC NC NC NC NC GND 16 NC NC NC NC NC GND 15 NC NC NC NC NC GND 14 13 Key Area 12 11 NC NC NC NC NC GND 10 NC NC NC NC NC GND 9 NC NC NC NC NC GND 8 NC NC NC NC NC GND 7 NC NC NC NC NC GND 6 NC NC NC NC NC GND 5 NC NC NC NC NC GND 4 NC NC NC NC NC GND 3 NC NC NC NC NC GND 2 NC NC NC NC NC GND 1 NC NC NC NC NC GND Note On the CP RI06 923 F 8M12 rJ4 has no connections at all and is only provided for mechanical stability 13 CP RI06 923 F User Guide www kontron com Hardware De
14. ards connect to J3 J4 and J5 but the backplane provides slot interconnection and RIO support the CP RI06 923 F can be used without restrictions WARNING A If the CP RI06 923 F is used with a backplane that supports slot interconnect on J3 to 35 as well as RIO support make sure that no other board in the system connects to J3 to J5 Otherwise unpredict able behaviour or even damage may occur The CP RI06 923 F is a rugged design intended to be used in harsh environments and features e Support of extended temperature range e Optional conformal coating High shock amp vibration capabilities Three variants are available providing different numbers and types of Ethernet ports e CP RI06 923 F Dual slot 8HP width with 24 1000Base T RJ45 Ethernet ports e CP RI06 923 F12 Single slot 4HP width with 12 1000Base T RJ45 Ethernet ports e CP RI06 923 F 8M12 Single slot 4HP width with 8 100Base TX Industrial M12 Ethernet ports 2 CP RI06 923 F User Guide www kontron com Introduction 1 2 Technical Specification Table 1 1 6 923 Main Specifications CP RI06 923 F SPECIFICATIONS 6U CompactPCI Front panel 1 0 board e 233 mmx 160 mm Mechanical Weight e 06 923 380g e P RI06 923 F12 320g e CP RI06 923 F 8M12 400g Temperature e Operating 40 C to 85 C Designed to meet or exceed the following e Bellcore GR63 Section 4 1 Operating 15 90 non condensing at 55 C 131 F
15. are present their temperature restrictions must be taken into account xii CP RI06 923 F User Guide www kontron com Preface Regulatory Compliance Statements FCC Compliance Statement for Class B Devices This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful inter ference in a residential installation This equipment generated uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures e Reorient or relocate the receiving antenna e Increase the separation between the equipment and receiver e Connect the equipment into an outlet on a circuit different from that to which the receiver is connect ed e Consult the dealer or an experience radio TV technician for help WARNING A This is a Class B product If not installed in a properly shielded enclo A sure and used in accordance with this User s Guide this product may cause radio inter
16. components used structural parts printed circuit boards connectors batteries etc are capable of being recycled Final disposition of this product after its service life must be accomplished in accordance with applicable country state or local laws or regulations vi CP RI06 923 F User Guide www kontron com Preface Before you Begin Before handling the board read the instructions and safety guidelines on the following pages to prevent damage to the product and to ensure your own personal safety Refer to the Advisory Conventions section for advisory conventions used in this user s guide including the distinction between Warnings Cautions and Notes e Always use caution when handling operating the computer Only qualified experienced authorized electronics service personnel should access the interior of the computer The power supplies produce high voltages and energy hazards which can cause bodily harm e Use extreme caution when installing or removing components Refer to the installation instructions in this user s guide for precautions and procedures If you have any questions please contact Kontron Technical Support WARNING A High voltages are present inside the chassis when the unit s power A cord is plugged into an electrical outlet Turn off system power turn off the power supply and then disconnect the power cord from its source before removing the chassis cover Turning off the system power switch do
17. ed or deactivated To install the RIO module in a system proceed as fol lows 1 Ensure that the safety requirements indicated in section 2 1 are observed gt WARNING Failure to comply with the instruction below may cause damage to the board or result in improper system operation WARNING A Care must be taken when applying the procedures below to ensure A that neither the CP RI06 923 F nor other system boards are physi cally damaged by the application of these procedures 2 Carefully insert the board into the slot designated by the application requirements for the board until it makes contact with the backplane connectors WARNING A DO NOT push the board into the backplane connectors Use the ejec A tor handles to seat the board into the backplane connectors 3 Using both ejector handles engage the board with the backplane When the ejector handles are locked the board is engaged 4 Fasten the front panel retaining screws 5 Connect all external interfacing cables to the board as required 6 Ensure that the board and all required interfacing cables are properly secured 6 CP RI06 923 F User Guide www kontron com Installation 2 3 Removal Procedure For removing the CP RI06 923 F it is not required that the system is powered down or the switch board in the corresponding front slot is removed or deactivated To remove the RIO module proceed as follows 1 Ensure that the safety requirements indica
18. es not remove power to components vii CP RI06 923 F User Guide www kontron com Preface When Working Inside a Computer Before taking covers off a computer perform the following steps e Turn off the computer and any peripherals e Disconnect the computer and peripherals from power sources or subsystems to prevent electric shock or system board damage This does not apply to when hot swapping parts e Disconnect telephone or telecommunications lines from the computer In addition take note of these safety guidelines when appropriate e help avoid possible damage to system boards wait five seconds after turning off the computer be fore removing a component removing a system board or disconnecting a peripheral device from the computer When you disconnect a cable pull on its connector or on its strain relief loop not on the cable itself Some cables have a connector with locking tabs If you are disconnecting this type of cable press in on the locking tabs before disconnecting the cable As you pull connectors apart keep them evenly aligned to avoid bend ing any connector pins Also before connecting a cable make sure both connectors are correctly oriented and aligned N CAUTION i A Do not attempt to service the system yourself except as explained in A this user s guide Follow installation and troubleshooting instruc tions closely viti CP RI06 923 F User Guide www kontron com Preface
19. ference in which case users may need to take addi tional measures at their own expense Safety Certification All Kontron equipment meets or exceeds safety requirements based on the IEC EN UL CSA 60950 1 family of standards entitled Safety of information technology equipment All components are chosen to reduce fire hazards and provide insulation and protection where necessary Testing and reports when required are performed under the international IECEE CB Scheme Please consult the Kontron Safety Conformity Policy Guide for more information CE Certification The product described in this user s guide was tested in a representative system and is found to be compliant with the CE marking requirements For computer systems to remain CE compliant only CE compliant parts may be used Maintaining CE compliance also requires proper cable and cabling techniques Although Kon tron offers accessories the customer must ensure that these products are installed with proper shielding to maintain CE compliance Kontron does not offer engineering services for designing cabling systems In addition Kontron will not retest or recertify systems or components that have been reconfigured by custom ers xiii CP RI06 923 F User Guide www kontron com Preface Two Year Warranty Kontron AG grants the original purchaser of Kontron s products a TWO YEAR LIMITED HARDWARE WARRANTY as described in the following However no other warranties that
20. ich are accessible via the module are listed in the following table Table 3 1 Ethernet Port Mapping PICMG 2 16 Backplane Port CP RI06 923 F Port Label CP RI06 923 F12 Port Label FL Fx FL 01 1x 1x FL_02 2x 2x FL_03 3x 3x FL_04 4x 4x FL 05 5x 5x FL 06 6x 6x FL 07 7x 7x FL_08 8x 8x FL_09 9x 9x FL_10 10x 10x FL_11 11x 11x FL_12 12x 12x FL_13 13x FL_14 14x FL_15 15x FL_16 16x FL_17 17x FL_18 18x FL_19 19x FL_20 20x FL_21 21x gt FL_22 22x FL_23 23x 9 CP RI06 923 F User Guide www kontron com Hardware Description Note that ports marked with a are not available at the module The RJ45 connectors are not equipped with LEDs for displaying the link status or activity These are on the switch board front panel The next table shows the pin assignment of one 10 100 1000BASE T RJ45 connector Table 3 2 RJ45 Pin Assignment BI_DB BI_DB BI_DA BI_DD BI_DD BI_DA BI_DC BI_DC NO WT HR W Ne 3 2 M12 100BASE TX Ports The CP RI06 923 F 8M12 supports 100Base TX operation on eight Industrial M12 D coded female connec tors on the front panel There is a separate magnetics device for each port The module supports PICMG 2 16 backplane ports FL12 to FL19 The switch interfaces which are accessible via the CP RIO6 923 F 8M12 are listed in the following table Table 3 3 Ethernet Port Mapping PICMG 2 16 Backplane Port CP RI06 923 F 8M12 Port Label FL
21. ity for any given task remains that of the purchaser In no event will Kontron be liable for direct indirect or consequen tial damages resulting from the use of our hardware or software products or documentation even if Kontron were advised of the possibility of such claims prior to the purchase of the product or during any period since the date of its purchase Please remember that no Kontron Modular Computers GmbH employee dealer or agent is authorized to make any modification or addition to the above specified terms either verbally or in any other form written or electronically transmitted without the company s consent xiv CP RI06 923 F User Guide www kontron com Chapter 1 Introduction www kontron com Introduction 1 Introduction 1 1 Product Overview The CP RI06 923 F CP RI06 923 F12 and CP RI06 923 F 8M12 hereinafter all generally referred to as CP RI06 923 F are a family of PICMG 2 0 compliant 6U rear panel 1 0 board that can be used with PICMG 2 16 compliant switches like the CP6923 or CP6930 They provide access to up to 24 of the switch ports connected over a one to one backplane This module is intended to access the backplane ports of a PICMG 2 16 compliant switch board directly These are the ports located on connectors J3 J4 and J5 Any connections on the backplane on these connectors between the switch and any other board are not usable together with the RIO module However if no other bo
22. may be granted or implied by anyone on behalf of Kontron are valid unless the consumer has the express written consent of Kontron AG Kontron AG warrants their own products excluding software to be free from manufacturing and material defects for a period of 24 consecutive months from the date of purchase This warranty is not transferable nor extendible to cover any other users or long term storage of the product It does not cover products which have been modified altered or repaired by any other party than Kontron Modular Computers GmbH or their authorized agents Furthermore any product which has been or is suspected of being damaged as a result of negligence improper use incorrect handling servicing or maintenance or which has been dam aged as a result of excessive current voltage or temperature or which has had its serial number s any other markings or parts thereof altered defaced or removed will also be excluded from this warranty If the customer s eligibility for warranty has not been voided in the event of any claim he may return the product at the earliest possible convenience to the original place of purchase together with a copy of the original document of purchase a full description of the application the product is used on and a description of the defect Pack the product in such a way as to ensure safe transportation see our safety instructions Kontron provides for repair or replacement of any part assembly or sub a
23. s developed and tested carefully to provide all features necessary to ensure its compliance with electrical safety requirements It was also designed for a long fault free life However the life expectancy of your product can be drastically reduced by improper treatment during unpacking and installation Therefore in the interest of your own safety and of the correct operation of your new Kontron product you are requested to conform with the following guidelines gt WARNING A All operations on this device must be carried out by sufficiently skilled personnel only WARNING gt Do not connect a switch port to a telephone line A WARNING For installation in a Hot Plug system observe the safety instructions specific to the system Read the relevant documentation N CAUTION A Electric Shock High voltages are present inside the chassis when the unit s power cord is plugged into an electrical outlet Turn off system power turn off the power supply and then disconnect the power cord from its source before removing the chassis cover Turning off the system power switch does not remove power to components gt gt x CP RI06 923 F User Guide www kontron com Preface Special Handling and Unpacking Instructions ESD Sensitive Device This symbol and title inform that electronic boards and their components are sen sitive to static electricity Therefore care must be taken during all handling oper
24. s no responsibility for any damage resulting from failure to comply with these requirements ESD Sensitive Device This CompactPCI board contains electrostatically sensitive devices Please observe the necessary precautions to avoid damage to your board e Discharge your clothing before touching the assembly Tools must be dis charged before use e When unpacking a static sensitive component from its shipping carton do not remove the component s antistatic packing material until you are ready to install the component in a computer Just before unwrapping the anti static packaging be sure you are at an ESD workstation or grounded This will discharge any static electricity that may have built up in your body e When transporting a sensitive component first place it in an antistatic con tainer or packaging e Handle all sensitive components at an ESD workstation If possible use an tistatic floor pads and workbench pads Handle components and boards with care Do not touch the components or contacts on a board Hold a board by its edges or by its metal mounting bracket e Donothandle or store system boards near strong electrostatic electromag netic magnetic or radioactive fields 5 CP RI06 923 F User Guide www kontron com Installation 2 2 Installation Procedure For installing the CP RI06 923 F it is not required that the system is powered down or the switch board in the corresponding front slot is remov
25. scription Table 3 7 J5 Connector Pin Assignment De 21 20 19 18 17 16 15 14 13 12 11 pa e NU 5 U N CO FL_DA19 FL_DB19 FL_DA18 FL_DB18 FL_DA17 FL_DB17 FL_DA16 FL_DB16 FL_DA15 FL_DB15 FL_DA14 FL_DB14 FL_DA13 FL_DB13 FL_DA12 FL_DB12 FL_DA11 FL_DB11 FL_DA10 FL_DB10 FL_DA9 0894 FL 19 FL DB19 FL DA18 FL DB18 FL 17 FL DB17 FL DA16 FL DB16 FL DA15 FL DB15 FL DA14 FL DB14 FL DA13 FL DB13 FL DA12 FL DB12 FL DA11 FL DB11 3 FL DA10 FL 10 3 FL 9 3 FL DB9 3 GND GND GND GND GND GND GND GND GND GND GND GND GND GND GND GND GND GND GND GND GND FL DC19 FL DD19 FL DC18 FL DD18 FL DC17 FL DD17 FL DC16 FL DD16 FL DC15 FL DD15 FL DC14 FL DD14 FL DC13 FL DD13 FL DC12 FL DD12 FL DC11 FL DD11 FL DC10 FL DD10 3 FL DC9 FL DD9 3 FL DC19 FL DD19 FL DC18 FL DD18 FL DC17 FL DD17 FL DC16 FL DD16 FL DC15 FL DD15 FL DC14 FL DD14 FL DC13 FL DD13 FL DC12 FL DD12 FL DC11 FL DD11 3 FL DC10 FL DD10 3 FL DC9 FL DD9 3 GND GND GND GND GND GND GND GND GND GND GND GND GND GND GND GND GND GND GND GND GND GND FL9 FL10 and FL11 are not connected to the backplane on the CP RI06 923 F 8M12 variant
26. ssembly at their own discretion or to refund the original cost of purchase if appropriate In the event of repair refunding or replacement of any part the ownership of the removed or replaced parts reverts to Kontron Modular Computers GmbH and the remaining part of the original guarantee or any new guarantee to cover the repaired or replaced items will be transferred to cover the new or repaired items Any extensions to the original guarantee are consid ered gestures of goodwill and will be defined in the Repair Report issued by Kontron with the repaired or replaced item Kontron Modular Computers GmbH will not accept liability for any further claims resulting directly or indi rectly from any warranty claim other than the above specified repair replacement or refunding In particu lar all claims for damage to any system or process in which the product was employed or any loss incurred as a result of the product not functioning at any given time are excluded The extent of Kontron Modular Computers GmbH liability to the customer shall not exceed the original purchase price of the item for which the claim exists Kontron Modular Computers GmbH issues no warranty or representation either explicit or implicit with respect to its products reliability fitness quality marketability or ability to fulfil any particular application or purpose As a result the products are sold as is and the responsibility to ensure their suitabil
27. ted in section 2 1 are observed WARNING A Care must be taken when applying the procedures below to ensure A that neither the CP RIO6 923 F nor system boards are physically damaged by the application of these procedures 2 Disconnect any interfacing cables that may be connected to the board 3 Unscrew the front panel retaining screws 4 Disengage the board from the backplane by first unlocking the board ejection handles and then by pressing the handles as required until the board is disengaged 5 After disengaging the board from the backplane pull the board out of the slot 6 Dispose of the board as required 7 CP RI06 923 F User Guide www kontron com Chapter 3 Hardware Description www kontron com Hardware Description 3 Hardware Description This chapter describes the board specific features of the CP RI06 923 F The building blocks are e Ethernet ports e CompactPCI bus connectors The module does not require a power supply There are no active components on the board 3 1 RJ45 1000BASE T Ports On the RJ45 variants three Integrated Connector Modules network magnetics RJ45 are the physical interface for the 10 100 1000Base T ports there are three 2x4 modules on the CP RI06 923 F and three 1x4 modules on the CP RI06 923 F12 The CP RI06 923 F supports PICMG 2 16 backplane ports FL1 to FL23 and FLf Fabric to Fabric Link Port The CP RI06 923 F12 supports FL1 to FL12 The switch interfaces wh