1. 10 Vdc 1 Vdc Earth connection Although a terminal is offered for earth connection the connection is optional The instrument does not need this connection for 100 mVdc correct functioning nor for compliance with the security regulations DC Volt Input signal lecti Fuse To comply with security regulation 61010 1 add to the power line labi SE Voltages NOME signal range selection a protection fuse acting as disconnection element easily accessible to the operator and identified as a protection device Power H fuse 250mA time lag Power L fuse 400mA time lag FEMA ELECTRONICA Page 3 User s Manual S 40 D Technical Data Technical Data cont Digits Type Height Display maximum Display minimum Decimal point Overrange Underrange Signals accepted Ranges selectable Connections Types Input impedance Maximum input signal Accuracy at 25 C Acquisitions Display refresh Step response time 4 7 segments red 14mm 9999 1999 selectable 8 8 8 8 9999 flashing 1999 flashing Vdc Adc 600Vdc 100Vdc 10Vdc 1Vdc 100mVdc 5Adc 1Adc 2 wire active signals see table 3 see table 3 see table 3 15 acquisitions second 15 display refresh second lt 210mSec 0 to 99 signal Response time for changes less than 10 FS is lt 75mSec Thermal stability offset span Power Power
2. 2K 4 5Vdc permanent 20mOhm 20mOhm 16A 5 sec 16A 5 sec Table 3 Input signal range specifications FEMA ELECTRONICA Page 4 User s Manual S40 D Mechanical Dimensions mm Information Menu 13 C cane HHHH mA or Vdc 3624 IAA a Configuration ro F E C i ILO 7 BABA C Input Low Te 184 80 8 3 dLa jana Display Low T Panel 32 5 cut out hi affi Input High dhl BEA Display High 69 l rm T 1 i Operating the Information Menu AA BOGE seno Maximum To enter the Information Menu press the SQ button The os _ Information Menu allows to visualize information and does HI n BEBE Memory of minimum not allow to modify the configuration of the instrument It is Minimum not affected by the PASSWord function During operation with the Information Menu alarms remain frozen and are Ti kept on hold Leaving the Information Menu returns to the A LOI H H H H aii measuring state of the instrument without restart Alarm1 HHHH mermi
3. Information Menu Tree See page 5 BBA A Setpoint Rollback After 30 seconds without interaction from the L gt Count operator the instrument leaves the Information Menu h 1 5 Al Al Al Al sai YSTEresis Button SQ Selects the visible option a P Y d E L Ha AA Seconds Button UP Moves vertically along the available menu op Delay tions ZI 1 IC Second Button LE Leaves selected menu or leaves the Informa E E E E A zi zi setpoint Setpoint2 tion Menu 3 7 z I ZI Information Menu Description Lig Sani LI r J See menu for Alarm1 Configuration Conf Information on the configured input signal range 600V 5A and the values for input low ILo Al J r H See menu for Alarm1 display low dLo input high Ihl and display high dhl Maximum MAX Value of the maximum display oFE HHHH Option installed Option1 Minimum Min Value of the minimum display 2 H Option installed AlarmX ALX Configuration of alarm X The sequence of aFE c HH De information shows if the alarm is being managed On Off the alarm type Max Min the setpoint the hysteresis value the activation delay and the value of setpoint2 Off or the HE A 5 pe HHHH i AHA setpoint2 value Measure Input range Measured value OptionX OptX Type of module installed If
4. H Power L Consumption Isolation Configuration 50 ppm C 100 ppm C 85 to 265 Vac dc 11 to 60 Vdc and 24 48Vac lt 4W 3500Veff for power H 2000Veff for power L all levels tested for 60 seconds 3 frontal push buttons and rear jumper for signal selec tion in Vdc or mA Functions available Fixed digits Filter on display Steps Memory of maximum Memory of minimum Zeros to the left Password Measure function Auto correction high Auto correction low Peak amp Hold Double setpoints Brightness control Options Mechanical Mounting Connections Weight Housing materials Front size Panel cut out Deep from panel Protection Temperature Operation Temperature Storage Warm up yes configurable yes recursive configurable yes configurable yes yes yes configurable yes configurable yes yes yes yes yes yes 5 levels maximum 2 panel plug in screw terminals lt 150 grams ABS polycarbonate vergaflex 72x36mm 69x32 5mm 98mm including terminal IP54 standard IP65 optional sealed front filter Opening the housing breaks the seal 0 to 50 C 20 to 70 C 15 minutes 600 Vdc 0 10 FS 20MOhm 1500Vdc permanent 100 Vdc 0 10 FS 2MOhm 200Vdc permanent 10 Vdc 0 10 FS 200K 200Vdc permanent 1 Vdc 0 10 FS 20K 65Vdc permanent 100 mVdc 5Adc 1 Adc 0 10 FS 0 15 FS 0 15 FS
5. there is no module shows nonE Measure MEAS Multimeter function Shows the value of the input signal without scaling This is the real value the instrument is receiving on terminals in Vdc or mA FEMA ELECTRONICA Page 5 User s Manual S40 D Operating the Configuration Menu Configuration Menu To enter the Configuration Menu press the SQ button The aF LS GOL Range 600vac Configuration Menu allows to change the configuration of Input a the instrument Access to the Configuration Menu can be IH UL Range 100vac password protected with the function PASSWord During operation with the Configuration Menu the alarms remain gl Range 10Vdc frozen and are kept on hold When leaving the Configura IT k Range 1Vdc tion Menu the instrument performs a restart and new con IL figuration is applied During the restart of the instrument a ros R 1 100mVd short alarm deactivation is performed LIRE di 5 A Range 5Adc Configuration Menu Tree See page 6 and 7 a IR Range 1Adc Description of Configuration Menu functions See page LIRE 8 and 9 ScHl gt ILa HHBBH4 Rollback After 30 seconds without interaction from the Scaling Input Low operator the instrument leaves the Configuration Menu discarding all changes 7 L o 7 ARAB Display Low But
6. 2Ero an With left zeros Range and scaling 0 600Vdc 0 600 0 Left Zeros Decimal point XXX X o F F Without left zeros Alarms 1 2 3 and 4 Active Off not managed SERA Type maximum Setpoint 1000 Mi f i A H Goo a eee Hysteresis 0 counts Maximum r E 5 L Reset of maxim Delay 0 0 seconds Setpoint2 Off SIE Display Fixed digits Off Hi n A GGG memory of minim Average Off Minimum n Steps Off L C E 5 E Reset of minim Left zeros Off aaa Memory of maximum 1999 Memory of minimum 9999 PALd on BHE Peak amp Hold Off Peak amp Hold Time Sec Tools m F F Password Off Version XXX Ls patata Brightness 3 FEMA ELECTRONICA Page 7 Input Menu The input menu selects the input signal range Options avail able are 600Vdc 100Vdc 10Vdc 1Vdc 100mVdc 5Adc and 1Adc Jumpers 1234 at the rear of the instrument must be closed according to the range selected Otherwise the display will show erratical behavior Scaling Menu The display scaling is based on 4 parameters These param eters define the two points of the straight line signal display Input Low ILo Signal input low Display Low dLo Input High IhI Display High dhl Display low Signal input high Display high User s Manual S 40 D Setpoint SEt Value from 9999 to 1999 Alarm set point Hysteresis hySt Value from 0 to 9999
7. C NO Maximum current 8A resistive load Voltage 250 Vac continuously Instalable in Option1 and or Option2 Connections for Option Connections for Option2 ABCDE FGHIJ eee 000 KUM N OPQR L__ NC LNC Common Common Warranty All instruments are warranted against all manufacturing defects for a period of 24 MONTHS from the shipment date This warranty does not apply in case of misuse accident or manipulation by non authorized personnel In case of mal function get in contact with your local provider to arrange for repair Within the warranty period and after examination by the manufacturer the unit will be repaired or substituted when found to be defective The scope of this warranty is limited to the repair cost of the instrument not being the manufacturer eligible for responsibility on additional damages or costs You may need to access the inside of the instrument to insert additional options Use a flat screwdriver to unlock the upper clips marked with A Then unlock the lower clips marked with B and move out the front filter Let the inside of the instrument slide out of the housing To reinsert the instrument make sure that all modules are correctly connected to the pins on the display module Place all the set into the housing assuring that the modules cor rectly fit into the internal guiding
8. Panel meter 72x36mm size PZ Model 40 D for DC Voltages for DC Currents Panel meter for DC signals voltage and current monopolar and bipolar Measure in CAT III up to 300Vdc and CAT II up to 600Vdc Current measure with ranges for 5Adc and 1 Adc Instrument with reduced housing size with standard 14mm digit height Included measure function visualization of signal input without scaling automatic signal correction peak amp hold double setpoint alarms brightness control filters Universal power options in AC and DC signal retransmission and control options User s Manual S 40 D Meter 40 D Panel meter 72x36mm size for DC voltages and currents Panel meter for DC electrical signals in voltage and current monopolar and bipolar with measure in CAT IIl up to 300Vdc and CAT Il up to 600Vdc Provides measure function for temporary signal input visu alization without scaling automatic signal input correction to associate the actual input signal to the Display High value span correction or to the Display Low value Offset cor rection peak amp hold double setpoint alarms and more Reduced size 72x36mm DIN standard instrument maintains standard 14mm digit height with full 4 digit resolution plus additional negative sign Connections via plug in screw ter minals and configuration via three front push buttons For application on industrial environments Management for up to 4 alarms wi
9. Points of hyster esis The hysteresis applies on the deactivation of the alarm Delay dEL Value from 0 0 to 99 9 seconds Delay to be applied to the relay activation and deactivation Relays are activated and deactivated X seconds after the activation deactivation of the alarm The delay affects only to the relays The delay does not affect to the front leds Setpoint2 SEt2 Value from 1999 to 9999 Second setpoint The second setpoint allows for the creation of acti vation windows If the alarm is configured as maximum with setpoint 1000 and setpoint2 is configured at 1500 the alarm will be activated between 1000 and 1500 and the alarm will be deactivated when display is lt 1000 and gt 1500 Setpoint2 is affected on the same way as the setpoint with hysteresis and delays Decimal Point Menu Display Menu Select the position for the decimal point Modify with the LE button and validate with the SQ button Auto Correction Menu Assigns the current input signal value to the Input Low or Input High configuration parameters The new values for Input and Display are displayed Auto Low A Lo Select A Lo to set the current input signal value to the Input Low configuration parameter Auto High A hl Select A hl to set the current input signal value to the Input High configuration parameter AlarmX Menu The instrument manages up to 4 alarm
10. e select a step of 20 will make the display to change in steps of 20 1420 1440 1460 Left Zero LZEr Value On Off Select On to visualize zeros to the left Maximum MAX Memory of maximum display Indicates the maximum value of display since the last reset of the memory Memory is reset on the following cases manual reset from the Configuration Menu Maximum change on the input signal Input modification on the scaling Scaling change on the decimal point dP modification of the linear ization segments or instrument power down Minimum Min Memory of minimum display Indicates the minimum value of display since the last reset of the memory Memory is reset on the following cases manual reset from the Configuration Menu minimum change on the input signal Input modification on the scaling Scaling change on the decimal point dP modification of the linearization segments or instrument power down FEMA ELECTRONICA Page 8 Peak amp Hold P hLd Peak amp Hold function detects sharp drops in the displayed value and holds the display if a display drop is detected To disable the hold function for a moment press any of the front buttons or wait for a predefined time Time 0 hold disabled Off Time 1a3999 seconds before disabling the hold Time 4000 infinite hold The counting of seconds is started each time there is an in crease in the display value Alarms will follow the i
11. e power connection verify that the voltage level available matches the power levels indicated in the label on the instrument In case of fire disconnect the instrument from the power line fire alarm according to local rules disconnect the air conditioning attack fire with carbonic snow never with water FEMA ELECTRONICA Page 2 User s Manual S 40 D Front View Input signal connections Current The current measuring has a single jumper position Select Alarms E the input range in the configuration menu 12345 SOI 2 4 UL lt A st 1234 Jumpers for input signal range selection See Table 1 Adc on CS esse T O gt E Adc LE UP SQ Range Close Jumpers Rear View Table 1 DC currents Input signal range selection Option1 Option2 Input signal connections Voltage To configure the input signal range select the appropriate jumper according to Table 2 Also select the range in the configuration menu 12345 Signal Jumpers 1234 Power 1234 Jumpers for input signal range selection See Table 2 Vdc Power Connections Vdc 67890 OOO 600 Vdc 100 Vdc
12. iteria B 70 25 cycle Criteria B 0 250 cycle Criteria B Barber del Vall s October 2010 Daniel Junc Quality Manager FEMA ELECTRONICA Page 10 User s Manual S40 D FEMA ELECTR NICA Page 11 other products Panel Meters Panel Meters Panel Meters Standard 96x48mm Small 72x36mm Miniature 48x24mm pe lt Large Displays Signal Converters Panel Meters 60 amp 100mm digit amp Isolators Standard 96x48mm www fema es ELECTRONIC INSTRUMENTATION FOR INDUSTRY FEMA ELECTRONICA S A Altimira 14 Pol Ind Santiga E08210 Barbera del Vall s BARCELONA SPAIN Tel 34 93 729 6004 www fema es Fax 34 93 729 6003 info fema es
13. nput signal while hold is active Tools Menu Password Pass Select a number to act as password This password will be requested when entering the Configuration Menu To deactivate the password select Off Factory Settings Fact Factory default configuration Se lect ES to activate the factory default configuration Version Ver Firmware version installed Light Ligh Luminosity Select between 5 predefined levels of luminosity Options Menu Menu options OPT1 and OPT2 give access to the configura tion menus of the installed options The menu depends on the installed option If there is no option installed the instrument shows nonE User s Manual S 40 D Messages and errors When the instrument detects that the displayed value does not correspond to the input value the display will flash and alternate with a message h udr Hardware underrange The instrument is reading the lowest possible signal and can not follow lower signals h oVr Hardware overrange The instrument is reading the highest possible signal and can not follow higher signals d udr Display underrange The instrument is displaying the minimum value 1999 and can not display below d oVr Display overrange The instrument is displaying the maximum value 9999 and can not display above hoLd The instrument is showing the value present when the hold function
14. nt HOSE gt BEE cons Hysteresis GEL gt BGA Seconas Delay FEMA ELECTRONICA Page 6 User s Manual S 40 D Configuration Menu SE EC on PGA bool H PASS on BEBE etpoin o F F Second setpoint Tools Password 5 E F Select password LI l C cl See menu for Alarm1 E He E no B E y Factory Be yg E 5 Resets to factory de AL r J See menu for Alarm1 V fault values m L r L See menu for Alarm1 E E dl a HEr gt HHHH Firmware version Version d ISP F IHd on HOF55 Display Fixed Digits m E E Fix digits L I G si L I G Minimum brightness E Brightness eo Smee LI oe AU on EGEO LI Ed Default brightness Average 5 F F L I G L I G 5 Maximum brightness SEEPH on H dali Steps Ra o P L Configuration for Option1 Option 5 y Fi p L e Configuration for Option2 I LI Option2 y eu ene mn LI ol F ee Counts for step Default factory configuration L
15. r applications on industrial environ ments See the CE Declaration of Conformity further in this document for information on the category of measure and the degree of pollution levels that apply Installation of this instrument must be performed by qualified personnel only This manual contains the appropriate information for the installation Using the instrument in ways not specified by the manufacturer may lead to a reduction on the specified protection level Disconnect the instrument from power before starting any maintenance and or installation action The instrument does not have a general switch and will start operation as soon as power is connected The instrument does not have protection fuse the fuse must be added during installation The instrument is designed to be panel mounted An appropriate ventilation of the instrument must be assured Do not expose the instrument to excess of humidity Maintain clean by using a humid rag and do NOT use abrasive products such as alcohols solvents etc General recommendations for electrical installations apply and for proper functionality we recommend if possible install the instrument far from electrical noise or magnetic field generators such as power relays electri cal motors speed variators If possible do not install along the same conduits power cables power motor controllers electrovalves together with signal and or control cables Before proceeding to th
16. s Each alarm is controlled by the condition display higher or lower than the configured setpoint The front leds are controlled by the activation deactivation of the related alarm The relays installed on Option1 and or Option2 are controlled by Alarm1 and Alarm2 Active Act Value On Off Defines if the instrument has to manage this alarm or not Select Off for alarm not managed Type tyPE Value Max Min Defines the behavior of the alarm as maximum or minimum alarm The alarms config ured as maximum are activated when the display value is equal or higher than the setpoint The alarms configured as maximum are deactivated when the display is lower than the setpoint The alarms configured as minimum have the inverse behavior Functions on this menu allow for configuration of the visu alization Fixed Digits FIX d Allows a digit to be fixed to a predefined value for example least significant digit fixed to 0 It is a condition to fix a digit that all digits to its right are also fixed Value shows that the digit is not fixed Average AVr Recursive filter applied to display Value from 0 0 to 99 9 The severity of the filter increases with the value selected Increasing the severity of the filter makes the display response slower Steps StEP Display changes on predefined steps Values are 1 2 5 10 20 and 50 The display is made in steps of X counts For exampl
17. slides of the housing Once introduced place again the front filter by clipping first the upper clips A and then the lower clips B Important If your instrument was delivered with the IP65 front seal option accessing the inside of the instrument will perma nently break the IP65 seal on the areas of clips A and B CE Declaration of Conformity Manufacturer FEMA ELECTRONICA S A Altimira 14 Pol Ind Santiga E08210 Barbera del Vall s BARCELONA SPAIN www fema es info fema es Products S40 D The manufacturer declares that the instruments indicated comply with the directives and rules indicated below Directive of electromagnetic compatibility 2004 108 CEE Directive of low voltage 73 23 CEE Security rules 61010 1 Equipment Fixed Permanently connected Pollution degree 1 and 2 without condensation Isolation Double Category CAT III up to 300V CAT II up to 600V Emission rules 61000 6 4 Generic rule of emission Immunity rules 61000 6 2 Generic rules of immunity 61000 4 2 By contact 4KV Criteria B On air 8KV Criteria B 61000 4 3 Criteria A 61000 4 4 On AC power lines 2KV Criteria B On DC power lines 2KV Criteria B On signal lines 1KV Criteria B 61000 4 5 Between AC power lines 1KV Criteria B Between DC power lines 0 5KV Criteria B 61000 4 6 Criteria A 61000 4 8 30A m at 50Hz Criteria A 61000 4 11 0 1 cycle Criteria A 40 10 cycle Cr
18. th 1 or 2 setpoints each with hysteresis and delays Functions available include memory of maximum and minimum left zeros steps on dis play fixed digits recursive display filter password brightness control function measure for visualization of input signal without scaling offset and signal high autocorrection and peak amp hold function Power options in AC and DC with universal range power modules and space for two additional control and or retrans mission modules For measurements in CAT III depends on the range se lected and for environments with degree of pollution 1 and 2 without condensation Standard IP54 front protection with optional upgrade to IP65 protection Order Reference Model Power Option1 Option2 Others S40 D H _ H 85 265 Vac dc R1 1 relay R1 1 relay 65 IP65 L 11 60 Vdc AO Analogue Output AO Analogue Output empty and 24 48 Vac empty empty Precautions on installation Risk of electrical shock Instrument terminals can be connected A to dangerous voltage Instrument is in conformity with CE rules and regulations See Instrument protected with double isolation No earth connection required CE Declaration of Conformity further in this document This instrument has been designed and verified according to the 61010 1 CE security regulation and is designed fo
19. ton SQ Moves horizontally on the menu Allows selec I JSJ ooogo tion of the current option displayed During a value selection gt hl AAA Al menu for example a setpoint value validates the value on Input High display A gt dhi gt BEBBE Button UP Moves vertically on the menu Displays the Display High available menu options During a value selection menu for i 3 Pressi EE torchange selection example a setpoint value increases digit value from 0 to 1 D dP n Good 2 i 2 3 4 5 6 7 8 9 Sii Acar Alo 8888 588688 Button LE Leaves the current menu Pressing LE several Auto correction Auto Low Signal Low Display Low times will leave all menus and leave the Configuration Menu tree During a value selection menu for example a setpoint Ahl AHAB HAAA value allows to select each digit for modification with the Auto High Signal High Display High UP button See Reset Leaving the Configuration Menu forces a restart of A LI the instrument even in case of no changes in configuration Alarms AL C i He 7 Dn Alarm Alarm1 Active On management Inactive Off LI F F Max Maximum MM I PARO Wine Minimum til Alarm as minim i PE gt fla H Alarm as maxim a SEE AEA Setpoi
20. was activated Hold function is active Min The instrument displays the minimum displayed value in memory The minimum visualization is active MAX The instrument displays the maximum displayed value in memory The maximum visualization is active P hLd The instrument displays the peak value Function Peak amp Hold is active Err 0 Values introduced on the ScAL menu are not valid Default values are activated The slope defined by the two points is almost vertical higher than 5000 Err 1 Err 2 The instrument has detected an installed option but was unable to communicate Err 3 Related to the edition of a linearization point Re turns to the point for further edition The value of InPX of the edited point is lower than InPX of the previous point Err 4 Related to the activation Act of the lineariza tion segments Ad dl Activation is not allowed The value InPX of one of the points is higher than InPX of the next point Err 5 Related to the activation Act of the linearization segments Ad dl Activation is not allowed The slope de fined by one of the segments is almost vertical Password incorrect Slope condition for Err 0 and Err5 dhl dLo Counts Ihl ILo mA or Vac lt 5000 FEMA ELECTRONICA Page 9 User s Manual S 40 D Option RI 1 relay Accessing the instrument Relay type 3 contacts Com N