1. The filter module does not contain any anti freeze agent Therefore the ultrafiltration module may not be exposed to frost as this can lead to damage of the membrane 2 Storage as a spare part Originally packed SMP modules can be stored for up to two years under the following conditions 1 The original packaging must not be removed and must not be damaged so the modules are prevented from drying out 2 The modules may not be exposed to direct sunlight and must be stored in a cool dry place 3 The storage temperature must be between 2 and 20 C 35 68 F 4 The module is stored vertically with the connections upwards 3 Storage after operation A filter module which has already been rinsed and taken into operation can be safely stored for up to six months after a thorough flushing with pure water and adding a 1 sodium bisulfite solution to avoid biological growth and contamination For storage that is longer than six months the module must be washed out again cleaned in the case of strong contamination and rinsed and handled as described above In any case the ultrafiltration module must be rinsed out with an adequate quantity of pure water clean drinking water before renewed usage Make sure the modules are sealed using the original Seccua protective end caps and are prevented from drying out as well as stored in a cool and dry place Store the modules vertically with the opening facing upwards Doc Rev 19122011
2. This system was manufactured to the highest quality standards The warranty and guarantee conditions of our general terms and conditions apply The guarantee voids if the system is not operated stored transported or mounted properly according to the conditions described in this manual The removal performance of pathogens by ultrafiltration membranes is very high The manufacturer has specified removal rate of 99 99 for viruses and 99 999 for bacteria However complete germ removal cannot be guaranteed by any technical system even with an ultrafiltration membrane The warranty obligor for each Region or country of purchase is identified below and is referred to as Seccua herein Seccua s warranty obligations are limited to the terms set forth below Warranty Coverage Seccua warrants Seccua branded hardware against defects in materials and workmanship when installed and operated within Seccua s specifications for a period of ONE 1 YEAR from the date of startup by the original end user or eighteen 18 months from date of ex factory shipment from Seccua whichever comes first Warranty Period If a hardware defect arises and a valid claim is received within the Warranty Period Seccua will at its option exchange the part with a new or refurbished part that is at least functionally equivalent to the original part A replacement part assumes the remaining warranty of the original part When a part is exchanged any repl
3. filter is heavily contaminated dicates that the system is filtering correctly If the left LED If only the red LED blinks an error has occurred if the yellow and red LEDs blink at the same time an The middle LED lights up yellow when the filter module is error alarm must be read out contaminated and a filter change should be taken into consideration soon blinks a flushing is performed The right LED blinks red in the case of alarms and when indicating a required filter change 3 Display The control panel has a single line display comprised of up to 16 characters All communication with the control unit in regard to the selection of the menu and the performance of parameter changes is carried out via this display When the system is connected to the power mains the control unit automatically switches into the permanent volume flow display depending on the pre set units either in liters per minute or gallons per minute The control unit of the system is pre set to your relevant requirements at the factory in regard to the units and lan guage The display has the option of an automatic time out after which the lighting is switched off All systems are pre set to continuous lighting 7 2 Menu structure and operation The control unit of the system is laid out in a simple and clear manner It is restricted to the essential functions of an ultrafiltration system the filtration the cleaning of the filter module and ce
4. the parts In put of the module s serial key page 24 and Calibration page 30 and Set flush mode and minimum filtration duration page 25 Page 18 Doc Rev 100410 s SCCCUC UrSpring Ultrafiltration Unit 6 Operating States 6 1 Filtration The actual ultrafiltration takes place in the operating mode Filtration Water is forced from the feed side through the membrane filter onto the filtrate side Note The instructions on the programming of the system can be found in chapter 7 Control and Programming from page 21 Performance aia LD filtration time 100 Rg8 asannnnnann cee eee ieee eee New clean filter Increase of turbidity e g 60 i TL T ITL EECETEETECEEEE Pee an s ee Threshold for cleaning Cleaning at fouling threshold Fa Cleaning at fouling threshold delayed until min filtration time is reached Time 12 p m 6 p m 12 a m 6 a m Diagram 11 Depiction of a typical filtration cycle A filtration cycle always lasts until an automatically triggered cleaning of the system occurs A cleaning cycle is triggered by the following 1 A threshold value of filter fouling is reached e g decrease of the filter permeability which is obtained from the pressure difference and the volume flow the example shown above for instance shows a decrease to 60 of the initial output 2 Additionally it is performed at a certain time of day this is for in
5. The intelligent control electronic ensures that the filtration cycles of the system are automatically adapted to the fluctuating quality of the raw water In this manner it minimizes rinse water consumption and increases the comfort level by preventing an interruption in supply during water removal 7 1 Control panel of the control unit Diagram 12 Control panel of the control unit 1 Overview keyboard C sewa _ The Enter key activates the current or performed input or the currently shown Enter menu item By pressing this key the control advances to the associated sub l menu Selection key in order to navigate up a level between individual menu items Arrow key up w When pressing this key during the entry of numbers the displayed value is in creased Arrow key Selection key in order to navigate down a level between individual menu items down When pressing this key during the entry of numbers the displayed value is de creased Back Cancel key By pressing this key the current menu is exited and next higher Escap e menu is displayed Any earlier input not activated by pressing enter is deleted Doc Rev 19122011 Page 21 SCCCUG UrSpring Ultrafiltration Unit 2 LED lights and color code Color codes green everything is OK yellow filter performance is reduced red alarm caused by an error See error code or the The left LED lights up green during the filtration and in
6. Page 31 amp SCCCUG UrSpring Ultrafiltration Unit 8 2 Replacement of the filter module Note We recommend having the filter module in the system dismantled and replaced by an authorized service partner Schraube screw 4x Klemimring clamp Diagram 14 Module replacement Follow the following instructions when dismantling the filter modules 1 Close the inlet to the system 2 Open the drain valve of the system by triggering a manual flushing 3 Close the filtrate line downstream of the system if valve is available 4 The system must now be in a pressure less state 5 Ensure that any escaping water is collected Ensure that the system is completely free of pressure when removing the filter module If the system is not pres sure less there is the risk of injury and nothing may be changed in the system 6 Unscrew the end cap C from the module B by loosening the four cylinder head screws and take both side clamps out of the surrounding groove in the filter module 7 Now open the box with the new filter module and remove the module Carefully remove the packaging on the module Note For this see also the assembly instructions in this user manual on page 14 8 Place the new unpacked module flat side down centered above the end cap so that the O ring in the groove of end cap lies between the module and the cap 9 Place the two clamps in the surrounding groove on the underside of
7. esa gt 6enBue1 nn Te sumes F ra weJ6eip seq se nss d Ip MOUS ells 1611 MOUS S y MOY yoeg 91ug yoeg 91lud 5 3 shox yoeg nss d lJiq lt q none N OPIS 191 3 lt naua Jj geq buido D 3 Cc O _ S y mone akiwa yoeg Buisn oN S A 98 660 N 39S lt 191u3 c L a Sk 1 1ud A k 9 skoy moe uO Alle lt a Buisn JjO uO e660 HOMO Aled pel Q yoeg 1 tua SKOy MOY SS a S y moue y Buisn 08 00 utu 18g yoeg 08 00 nou 10S yoeg Tap qan s lnului pue sinou 38S lt 191 u3 gt pee lt 191u3 rep usnid S y MOY eset shoy MOY n S y moe jog ja usni enuen S y moue y Buisn Buisn pjoysesy 08 00 ulu 3S m paua 0 00 s1noy S PATE _ gt 09 gt moj u ym _g pequy Buljnoy ye ue o s lnuluu pue sunoy 38S Buljno 39S yoeg 133 pauma shoy MOLY ysn 4 19 u3 uw 0 0 AOl4 1J 1ug 6uiysny dois 49 Uy u nid UO JEMOd Page 23 Doc Rev 19122011 amp SCCCUG UrSpring Ultrafiltration Unit 3 Alarm All alarms are displayed by the lighting up of the red LED and can be read out and acknowledged via the menu Er ror Alarm The acknowledgement of an alarm is performed by pressing the Enter key If an alarm occurs in the system always determine the type of the alarm first then eliminate the cause of error if possible If the same alarm occurs r
8. filtration duration With this menu item the filtration and rinse cycles of the system can be programmed Doc Rev 19122011 Page 25 oY SCCCUG UrSpring Ultrafiltration Unit 1 Setting the contamination dependent cleaning Start Key Result Display examples Flow 0 0 gom Arrow key down Until Flush Mode is shown Enter Display Clean at fouling Enter Display when flow lt 60 Arrow keys Setting the threshold value which when reached triggers a cleaning cycle The value is determined from volume flow temperature and the pressure difference and in this manner indicates the actual contamination of the filter Enter Ends the entry and opens the menu for entering the minimum filtration duration Display Set hours 00 30 Arrow keys Setting the hours of the minimum filtra tion duration between two cleaning cycles via the arrow keys Enter Ends the entry Display Set min 00 30 Arrow keys Setting the minutes of the minimum fil tration duration between two cleaning cycles via the arrow keys Enter Ends the entry and jumps back to the menu Flush mode Display Clean at fouling Page 26 Doc Rev 100410 2 Setting a daily flushing s SCCCUG UrSpring Ultrafiltration Unit Start Key Result Display examples Flow 0 0 gom Arrow key down Until Flush mode is shown Enter Display Clean at fouling Arrow keys Until Fl
9. the country or state in which the part purchase took place Page 36 Doc Rev 100410 s SCCCUC UrSpring Ultrafiltration Unit Region Seccua Address The Americas Seccua Americas LLC 15508 West Bell Road Suite 101 440 Surprise AZ 85374 USA All other countries Seccua GmbH Krummbachstr 8 86989 Steingaden Germany Doc Rev 19122011 Page 37 EMA water SCCCUG UrSpring Ultrafiltration Unit 11 Appendix 11 1 Performance data at a filter load of 80 gal m x h 300 I m 2 x h 2 4 m h 10 57 gal min 1 2 m h 5 29 gal min at a pressure difference of 14 5 psi at 50 F 1 bar at 10 C 9 5 gal minute 8 4 gal minute Removal performance new module BC for viruses gt 99 99 for bacteria gt 99 999 for parasites gt 99 999 Typical water consumption during flushing The filter output was calculated at 10 C water temperature using drinking water with new membranes 11 2 Ultrafiltration module Membrane Extra robust single bore fiber Material Hydrophobic Polyethersulfone PES modified Active membrane surface UrSpring i6 UrSpring i3 complete system 8 m 86 Sq Ft 4 m 43 Sq Ft The higher the forward pressure upstream of the system the greater the filter output During cleaning draining is performed through the rinse water line as a free outflow is required Here the pressure is approximately 0 psi Ensure that the pressure diff
10. the filter module at a later date 5 Remove the power supply from the packaging connect the M12 plug with the connector on the system and hand tighten it Diagram 3 Rear view of the unit with attached bracket 5 8 Connection of the system to the water and sewage network The systems are easily mounted and integrated into existing piping systems All inlets and outlets are located on the valve block of the system and are fitted with a uniform 3 4 internal thread Furthermore they are optionally equipped with three adapters 3 4 internal thread to pipe with 22 mm outer diameter Use a commercial Teflon tape graded for use in a drinking water installation or permissible Teflon string for sealing the connection threading Do not use too much sealing material and be careful when screwing in the fittings Other wise hair cracks could occur in the plastic and the thread could be damaged If you use the adapters you do not require any additional sealing components as these are self sealing Never use hemp for sealing We generally recommend installation of a shut off option or a stop valve in the feed of the system in the rinse wa ter and in the filtrate line This simplifies later maintenance and cleaning work The unit should be installed with detachable connections to be able to remove or exchange the unit later Doc Rev 19122011 Page 15 oY SCCCUG UrSpring Ultrafiltration Unit 1 Connections and general procedure
11. EMA UrSpring Ultrafiltration Unit User Manual Page 2 oY SCCCUG UrSpring Ultrafiltration Unit For tips and tricks support and sharing of your experiences visit www support seccua com Doc Rev 100410 s SCCCUC UrSpring Ultrafiltration Unit Table of contents L APSO MON TION uu u sinew ce we eee ed cee eeeweteenmcesisee AE a E ENRERE 6 L MGTIO e r e E E A T E A E E E E E A E E 6 1 2 Guaranies GCONONION S uuu uuu uu uu uu 2 susssiassusaihasassyssuskuqasaupakapusqkhuskuskshiskukayqas 6 1 3 Contact for service and technical support J J nnna 7 2 Important Safety Instructions J T U U T T T J 8 3 Operating Conditions and System Layout 9 3 1 Operating data of the system J U Q 9 Be SySI Om UAV OU uuu u A E A E E A A A E E E EE 9 II i SROCK u 2 s au usa s u 9 2 Fraton DEFORMAN CS iaiwvscasecesunsevevunansdustbaweisswuvieninveawanedusiedsiesVeushontarldadswankox ebeswaseadieerdsveneeboosteleneswens 9 So Electrical CONMECUON sicas aa EE aaa aaan 10 4 System Description J Q u U 11 4 1 DIMENSIONS ANG weight U L
12. LIILIUUIIIILI IILI iI s awawawawwawswwwayuwkwwaquswawanawqawuwkipawawawaqqun 11 TOIMEN g G SOME PPIP E E sas 11 UU a erie cates Pasa eee NO es sS ass sss 11 4 2 Components of the UF system J U J J T T T 12 D li LI IO u Z u E ua 13 GOT ISU GEO L u uu E 2 sus assaawaasEa kunakanka aanaaaa 13 5 2 PACKING and package contents J J J J 13 So EICCUICAl CHECKING Lu u ua 2 ass ee twasesyeedineeveseuecessccsucenetct 13 5 4 Checklist casing and pre filtration J U 13 5 5 Required tools and material U J Q 14 5 6 Preparations for installation J U u 14 5 7 Unpacking and wall mounting of the system 14 5 8 Connection of the system to the water and Sewage netwolrk 15 1 Connections and general procedures 16 TORI CONS s uuu n seuinews cient asesasuwaassqsassukasasshisasmaskasasanmusaypashunkasa
13. R ANTICIPATED PROFITS INCLUDING LOSS OF PROFITS ON CONTRACTS LOSS OF THE USE OF MONEY LOSS OF ANTICIPATED SAVINGS LOSS OF BUSINESS LOSS OF OPPORTUNITY LOSS OF GOODWILL LOSS OF REPUTATION LOSS OF DAMAGE TO OR CORRUPTION OF DATA OR ANY IN DIRECT OR CONSEQUENTIAL LOSS OR DAMAGE HOWSOEVER CAUSED INCLUDING THE REPLACEMENT OF EQUIPMENT AND PROPERTY THE FOREGOING LIMITATION SHALL NOT APPLY TO DEATH OR PERSONAL INJURY CLAIMS SECCUA SPE CIFICALLY DOES NOT REPRESENT THAT IT WILL BE ABLE TO REPAIR ANY PART UNDER THIS WARRANTY OR MAKE A PART EXCHANGE WITHOUT RISK OF INTERRUPTION OF WATER SUPPLIES SECCUA SPECIFICALLY DOES NOT REPRESENT FULL REMOVAL OF PATHOGENS BY ITS SYSTEMS AT ALL TIMES Consumer Protection Laws FOR CONSUMERS WHO HAVE THE BENEFIT OF CONSUMER PROTECTION LAWS OR REGULA TIONS IN THEIR COUNTRY OF PURCHASE OR IF DIFFERENT THEIR COUNTRY OF RESIDENCE THE BENEFITS CONFERRED BY THIS WARRANTY ARE IN ADDITION TO ALL RIGHTS AND REMEDIES CONVEYED BY SUCH CONSUMER PROTECTION LAWS AND REGULATIONS Some countries states and provinces do not allow the exclusion or limitation of incidental or con sequential damages or exclusions or limitations on the duration of implied warranties or conditions so the above limitations or ex clusions may not apply to you This warranty gives you specific legal rights and you may also have other rights that vary by coun try state or province This Limited Warranty is governed by and construed under the laws of
14. T Display ofthe Mier SuQIUk uuu uu uuu u E uns aku ui n 28 2 Pressure diference Gisp ayuu uuu uuu dade Dun u ea 29 Te Se LUNGS u su oe sets ae tach EAAS ET E a Z E E S u 2 SE 29 DS PUI la s Ie PPI I I I E E 29 2 Units time format time of day water temperature 29 3 Factory Setting uuu uuu uuu u u neronen sutar r anrr E E E EENE EE EENES ESENE Ern SEENE NP STENA 29 AAG AUD Eni a a E EE E E A E A AN 30 8 Error display and error COCESG ccsecceeeceseceeeceneeeeeceeecceeeceecaeetaueteueteeeeeeeeeeaeeeaeensesteetaeetaeeees 30 8 Maintenance and Cleaning J U Q 31 6 1 Storage of the fillermod ule LULU Ras s sss 31 T 9 L uu nn uu m a uum ee E eae ee 31 2 Storage as A spare pDarluuuu uuu eE EE E EE E E aE EEEE EENE 31 3 OLOFAGS anter 6Op6rgli6 uyu uuu u uu aa E a ai 31 8 2 Replacement of the filter module 32 9 IFTOLDDIGSTHIOOLI GO Uu cst ue cee nceuecetsunsmatucsndawusesnednwesessnvenssdebeuscwadehsusnesdcupssuenwacieeseuneustesee 34 10 Limited Warranty J Q U T 36 Page 4 Doc Rev 100410 O SeccuUq UrSpring Ultrafiltration Unit I LL PAPO SN UK enr E EEr Ea 38 11 1 Perfo
15. acement item becomes the original end user s property and the replaced item becomes Seccua s property Exclusions and limitations This Limited Warranty applies only to hardware parts manufactured by or for Seccua that may be identi fied by the Seccua trademark trade name or logo affixed to them The Limited Warranty does not apply to any non Seccua part or any software even if packaged or sold with Seccua hardware Manufacturers suppliers or publishers other than Seccua may provide their own warranties but Seccua in so far as it is permitted by law provides its parts as is Software distributed by Sec cua with or without the Seccua brand name including but not limited to system software is not covered under this Limited War ranty Refer to the licensing agreement accompanying the software for details of your rights with respect to its use Seccua does not warrant that the operation of the part will be uninterrupted or error free Seccua is not responsible for damage arising from failure of the parts This warranty does not apply a to damage caused by non Seccua products b to damage caused by accident abuse misuse flood fire earthquake or other external causes c to damage caused by operating the part outside the permitted uses described by Seccua d to damage caused by service including upgrades and expansions performed by anyone who is not a representat ive of Seccua or a Seccua Authorized Service Pr
16. acement of the system the module code of the filter must be re entered This contains factory data on the module type and each individual module This code is noted on the serial number label which is located on the module e g Code 000123 To perform this after connection of the system switch into the menu Settings and select the menu item Serial Key Follow the procedure described below Page 24 Doc Rev 100410 s SCCCUC UrSpring Ultrafiltration Unit Start Key Result Display examples Flow 0 0 gom Arrow key down Until Settings is shown Enter Display Language Arrow keys Display Serial Key Enter Display Number _ Arrow keys Enter 7 digit number shown on module Enter Switches to the next number key Back switches to the previous one Press enter after the last number Jumps back to the menu Serial Key Back Display Settings You are back in the main menu 4 Manual Flush The filter module of the system can be rinsed and cleaned manually at any time perform the following to do this Start Key Result Display examples Flow 0 0 gom Arrow key down Until Manual Flush is shown Enter Display Start flushing Enter Flushing is started feed pressure must be present Display Stop flushing Enter Flushing is stopped Display Start flushing Back Main menu item Display Manual Flush 5 Set flush mode and minimum
17. acknowledge the error An insufficient amount of wa System is in the rinse cycle Wait until the rinse cycle has been completed ter comes out of the filtration outlet Membrane capillaries are strongly contaminated Start a rinse as described in the user manual with particles from the raw water filtrate volume flow was higher at the time of commissioning Page 34 Doc Rev 100410 s SCCCUC UrSpring Ultrafiltration Unit and has reduced during operation Intervals between the rinse cycles is too long Adjust the settings for the flushing of the sys filtrate volume flow was higher at the time of tem depending on the raw water quality and commissioning and has reduced during opera reduce the set cycles up to flushing Feed pressure to the system is too low Contact your service partner or installer and ask them about possibilities for increasing the pressure upstream of the system Water suddenly tastes bad The conservation solution of the fiter module The module is conserved with a harmless was not rinsed out completely solution Rinse the system at the time of com missioning or after the replacement for a new module for a sufficiently long time to remove the conservation solution Flushing runs for too long Incorrect setting in the program Change the settings in the control unit as de scribed on page 25 ff Doc Rev 19122011 Page 35 oY SCCCUG UrSpring Ultrafiltration Unit 10 Limited Warranty
18. and accident prevention in structions Follow these additional directives for the safe operation of the system gt Vv Y Y WV VY Vv Y VY V WV Read this user manual carefully before the first commissioning All installations and or changes must be carried out by qualified experts Install the system exactly as described in the user manual Do not connect the system to the power mains if the connecting plug or cable is damaged Only authorized service technicians should perform maintenance on this system For any modifications or repairs contact your service partner Do not expose any electrical cables to water Do not kink the connecting cable Ensure that it is safely and sufficiently attached When performing any repairs disconnect the system remove it from the network and let it cool down Electrical protective measures in accordance with VDE 0100 must be checked by authorized experts Do not use any extension cords in the installation of the system The maximum pressure difference measuring points are upstream and downstream of the filter may not exceed 2 5 bar 36 26 psi Avoid pressure shocks These can be caused e g by shutting of external valves or switching of pumps in the feed or filtrate line of the system Warning Caution electrical voltage The power supply to the system must be interrupted before carrying out work on the control Page 8 Doc Rev 100410 s SCCCUC UrSpring Ultrafiltra
19. antee The guarantee cannot be claimed in the event of damages of the system caused by gt Transport gt Non expert use or incorrect installation gt Non expert and or insufficient maintenance gt Operation of the system outside of the operating conditions described in this user manual or gt Modifications to the system Please be sure that this user manual is always kept in the vicinity of the system and that it is handed over in the event of a change in ownership Page 6 Doc Rev 100410 O SCCCUC UrSpring Ultrafiltration Unit 1 3 Contact for service and technical support Should you require help with your system please contact your service partner or dealer directly Customer support Every effort has been made to assure the completeness and readability of these operating instructions If you have any problems or questions we would appreciate your letting us know so that we can improve this user manual Seccua GmbH Seccua Americas LLC Krummbachstr 8 15508 W Bell Rd Ste 101 440 86989 Steingaden Surprise AZ 85374 Germany United States of America Tel 49 0 8862 91172 0 Tel 1 623 986 5766 Fax 49 0 8862 91172 19 Fax 1 866 352 8178 Internet www seccua com Mail support seccua com Doc Rev 19122011 Page 7 amp SCCCUG UrSpring Ultrafiltration Unit 2 Important Safety Instructions In addition to the instructions contained in this manual be sure to heed all other safety
20. cally This mode will protect the membrane against dam age as far as possible However membrane damage can occur even with a very brief exceeding of the permissible maximum pressure difference between the feed and filtrate This emergency operation is maintained for 20 seconds then the system will switch back into filtration operation 6 4 Sterilization of the system e g after standstill Depending upon the ambient temperature and the contamination of the raw water with dissolved organic compon ents DOC germ growth takes place in standing water The number of germs increases exponentially and can lead to increased germ counts on the pure water side downstream of the system This contamination on the pure water side of the system are not germs from the raw water hence potential pathogens but germs from the line network which were already present before the installation of the system Hence attention must be paid to this during standstill periods of the system flushing the system must be carried out at least every 24 hours This measure serves the purpose of minimizing germ growth in the system After a prolonged standstill of the ultrafiltration system it must be washed out with a rinse with pure water before renewed usage A further supplementary option is the disinfection of the system before the renewed commission ing Page 20 Doc Rev 100410 s SCCCUC UrSpring Ultrafiltration Unit 7 Control and Programming
21. catastrophic faults in the system Rapidly closing valves whether activated manually or automat ically are without question the most frequent cause of pressure shocks in the application A valve closing in 1 5 seconds or less depending upon the size of the valve and the system conditions can cause an abrupt break in the flow A pressure shock audible wave caused by a rapidly closing valve can easily amount to several times the nor mal system pressure 2 Filtration performance The filtration performance of the system among other depends on the following parameters a The utilized filter surface area of the system b The flux rate i e the flux rate throughput per filter surface area Doc Rev 19122011 Page 9 amp SCCCUG UrSpring Ultrafiltration Unit System type Membrane surface area Long time flux rate Flow rate at peak load 2 ve ce h max 3001 m2 h UrSpring i6 8 m2 640 1 280 I h 2 4 m h 145 291 gal h 545gal h UrSpring i3 4 m2 320 640 I h 1 2 m h 72 145 gal h 272 gal h 3 3 Electrical connection The system is supplied with a power supply plug and adapter for different mains plugs The power supply plug provides the system with the required supply voltage An M12 plug 4 poles is located at the other end of the cable in order to connect to the covering hood roma fev few lomo om pov ew s fo Electrical shock gt Follow the instructions in this manual Failure to do s
22. crews 5 3 Electrical checklist Please make sure that the available electrical supply power supply cable and socket corresponds to the require ments of the system Note All electrical connections must be compliant with local ordinance and or DIN VDE directives Electrical shock Follow the instructions in this manual Failure to do so can cause serious injury or death Do not change the connecting plug or the connecting cable Make sure the power supply cable is never in water Do not use extension cords Always disconnect the system from the power supply pull the plug before carrying out installation and main tenance work 5 4 Checklist casing and pre filtration The system is delivered with two connection variants 1 The system is fitted with a metric 3 4 internal thread for connection of the feed the filtrate as well as the rinse water 2 Additionally the system is supplied with 3 4 speedfit couplings which are screwed into the valve block and are sealed by means of an O ring seal and are equipped with a speedfit coupling on the other side which is compatible with smooth pipe copper or plastic with an outer diameter of 22 mm Only utilize silicone grease tape grease or Teflon string for sealing screwed connections and never use fatty seal ant or hemp The latter offers a culture medium for germ growth Furthermore it can be solved in the water and cover the membrane with a layer of grease Th
23. ction available power socket for power supply Please check whether the wall intended for mounting is suitable to carry the weight of the system see chapter 4 1 Dimensions and weight and ensure a sufficient safe attachment of the system with the wall Is there sufficient space on the front side of the system to allow easy operation of the control unit and carrying out of servicing and maintenance Take sufficient space below the system into consideration in order to be able to easily perform later filter re placement approx 20 cm off the ground is sufficient Please observe all the relevant regulations at the time of installation The pressure in the system may not exceed 5 0 bar 72 5psi If necessary please install a pressure reducing valve to reduce the water pressure upstream of the system In any case the pressure difference between the feed and filtrate may not exceed 2 5 bar 36 26 psi 5 7 Unpacking and wall mounting of the system 1 Unpack the system 2 Secure the mounting plate with the supplied screws M8 to the system 3 Check whether any connecting screws have been loosened from the system during transport For this use the supplied Allen wrench Page 14 Doc Rev 100410 s SCCCUC UrSpring Ultrafiltration Unit 4 When mounting the system to the wall Keep a distance of at least 20 cm between the bottom end of the fil ter and the floor in order to facilitate easy installation and removal of
24. e connecting block of the system does not have to be removed during a later module replacement Therefore it can be connected in a rigid manner The pressure in the system at rest may not exceed 5 0 bar If necessary install a pressure reducing valve Doc Rev 19122011 Page 13 amp SCCCURCA UrSpring Ultrafiltration Unit The system has been designed for a maximum water temperature of 40 C Additionally the temperature of the wa ter in the feed may not drop below 4 C 89 F To ensure smooth filtration operation and in order to prevent membrane damage due to rough particles a pre filter max 300 um must be installed upstream of the system 5 5 Required tools and material Note We recommend that the system be installed and commissioned by a qualified installer The following tools and materials not included are required for wall and in line mounting Drill screws wall plugs four mounting screws Screwdriver Pipe wrench Measuring tape Bucket V V Y Y V WV Silicone grease depending on the installation type Teflon tape or equivalent food grade sealing agent for use with drinking water 5 6 Preparations for installation Mounting instructions Please check following points before mounting the device Are all the necessary water connections available feed raw water rinse water filtrate Is there a drain available at the location of installation rinse water Is the necessary electrical conne
25. epeatedly please contact your service partner An alarm with an opened flush valve can stop filtration until acknowledgement has been performed or the cause of the error has been eliminated An index of the alarm messages can be found in chapter 9 Troubleshooting page 34 73 Programming The system is delivered with a control unit that is pre configured for your requirements The language and the units of the system are already configured Therefore the following descriptions are in regard to the possible modifica tions of the settings on site 1 Sleep mode The control unit provides the option of changing into a sleep mode In this mode all settings are retained the system continues to filter and only the display lighting is automatically turned off after a certain amount of time We recommend returning to the display of filtrate volume flow after each programming In this manner it is always visible how much clean drinking water the system is currently producing 2 Filtrate volume flow display Depending on the settings in this state the current filtrate volume flow of the system is displayed In general there are two possibilities Either the filtrate volume flow can be displayed in liters per minute or in gallons per minute After switching on the system connection with the mains the control unit automatically displays this 3 Input of the module s serial key At the first activation as well as after a filter repl
26. erence between the feed and filtrate never exceeds 2 5 bar 36 26 psi This helps avoid 6 ing the risk of a filter damage to the membranes and increases the service life of the filter module Page amp Doc Rev 100410
27. essure Start Key Result Display examples Flow 0 0 gom Arrow key down Until Settings is shown Enter Display Language Arrow key down Until Calibrate Now is shown Enter Display Disconnect Water Enter Calibrates the zero point of the sensors Display Adjustment o k Enter Jumps back to the menu Settings 8 Error display and error codes The last occurring error is displayed in the error menu Start Key Result Display examples Flow 0 0 gom Arrow key down Until Error Alert is shown Enter Display Last Error 104 Enter While the error is displayed the mes sage can be acknowledged by pressing the enter key If no error message is present the user is returned to the main menu The error codes are explained in chapter 9 Troubleshooting Page 30 Doc Rev 100410 ts SCCCUC UrSpring Ultrafiltration Unit 8 Maintenance and Cleaning The systems are designed for low maintenance when the settings have been optimized for the individual require ments of the user and the information contained in the user manual is followed The intelligent control software auto matically recognizes possible errors and informs the user by means of the alarm signal the red LED which lights up on the display 8 1 Storage of the filter module 1 General The filter module was conserved with the conservation medium E223 sodium bisulfite and shipped Note
28. hread does not have to be sealed additionally 2 Put lubricant on the smooth pipe with an exterior diameter of 22 mm copper or plastic and push it into the coupling until the noticeable resistance of the O rings has been overcome Page 16 Doc Rev 100410 O SCCCUC UrSpring Ultrafiltration Unit Diagram 6 Insertion of the pipe in the quick Diagram 7 The coupling engages before the O coupling rings seal Diagram 8 Ensure that the inserted pipe has Diagram 9 Pull the pipe in order to ensure that been fully pushed into the quick coupling a force closed connection has been achieved 3 The pipe is disconnected by simply pressing the release ring Diagram 10 Pressing in the sleeve enables re moval of the pipe Important Fully release the pressure from the system before opening the quick couplings 2 Feed line The trans membrane pressure pressure difference between feed and filtrate side may not exceed 2 5 bar The pressure in the system at rest may never be greater than 5 bar It must be ensured that the filtrate can be drained off downstream of the system An operating pressure pressure between the feed and filtrate side of between 0 5 2 5 bar must be provided for filtration A sampling petcock in terconnection point must be mounted immediately downstream of the installation Install a back flow preventer downstream of the system 4 Drain line The drain line rinse wate
29. ing i3 approx 15 kg 33 Ibs 1268 mm 1055 mm Doc Rev 19122011 Page 11 4 2 oY SCCCUG UrSpring Ultrafiltration Unit Components of the UF system The system comprises a valve block with a covering hood and sensors as well as an ultrafiltration module and an end cap at the bottom end The attachment of the module to the block and the end cap to the module is performed by means of clamps which are inserted in the surrounding grooves of the module housing and fastened with M8 cylinder head screws Simple O ring seals provide the required tightness of the system The cover and control unit of system are firmly connected to the valve block with four countersunk head screws Page 12 Sschraube screw dx Klemmring clamp Abdeckung m Steverung cover with control Ventilblock m Haube valve block with cover 3 4 to 22 mm adaptor UF module schrauben Max screws M amp x20 kemming clamp Endkappe Haltewinkel end cap bracket Diagram 2 Components of the UF system Doc Rev 100410 O SCCCUC UrSpring Ultrafiltration Unit 5 Installation 5 1 General instructions Ensure that your shipment is complete and undamaged Note If your delivery is damaged or incomplete please contact our service desk immediately 5 2 Packing and package contents The system is delivered preassembled Please check the system after unpacking for damage and verify the secure attachment of the s
30. ne as this can damage the membrane filter Any deposits must be removed before connection to the system 2 Flushing of the system Proceed as follows for the flushing of the system 1 Install the system exactly as described above 2 Connect the power supply of the system connect mains plug and plug in 3 When the system is turned on for the first time the control unit will prompt the user to enter the serial num ber of the filter module Follow the procedure as described in chapter 7 3 Programming page 24 4 Begin the filtration and direct the filtrate downstream of the system into the drain Note Please ensure that the filtrate is discharged during the commissioning and flushing procedure and that it does not reach any pure water containers or the supply network 5 Rinse the system in this manner with at least 500 liters 130 gal of water approx 15 minutes with a feed pressure of approx 1 5 bar 22 psi and a free drainage at the collection point downstream of the system Make sure that the rinsed out water does not reach the line network downstream of the system 6 Slowly close the collection petcock downstream of the system 7 The flushing procedure of the system is now completed 3 Commissioning To finalize the commissioning the control has to be used to enter the module code calibrate the sensors and adapt the cleaning options if necessary To see how to do this read in chapter 7 Control and Programming
31. o can cause serious injury or death All electrical connections must be compliant with local ordinance and or DIN VDE directives Do not modify the connecting plug or the connecting cable Do not use extension cords Before opening the cover always disconnect the system from the power supply pull the power supply plug Page 10 Doc Rev 100410 s SCCCUC UrSpring Ultrafiltration Unit 4 System Description 4 1 Dimensions and weight 1 Dimensions Filtrat Ablauf oe Zulauf filtrate drain feed 1055 Tai 1015 F P LA cs Ww Haq P P j A Diagram 1 Dimensions in mm A distance of approx 20 cm 8 inch should be kept between the end cap and the ground to enable an easy ex change of modules at a later point in time There are four M8 threads on the rear of the valve block for wall mounting of the system For this the bracket delivered with the four M8 cylinder head screws is attached to the valve block Now the complete system can be mounted on the wall with the bracket For this purpose there are four holes with a diameter of 9 mm available with a distance of 180 mm horizontally and 35 mm vertically Viewed from the front the inlet feed is located to the left and the drain and filtrate outlet are to the right All connections are 3 4 threads and equipped optionally with adapters 3 4 to pipe with 22mm outer diameter 2 Weight UrSpring i6 approx 15 kg 33 Ibs 1268 mm 1055 mm UrSpr
32. or code 22 SD u te ee ala as adic che a pe tee cn oils ct sn u uu Z E n n un s 22 7 2 Menu structure and operation 22 TOC ON irae suan aa kaway anan E EEEE EEEE EO EET E EEEE 22 2 Menu structure of the control unit aa 22 i AEAEE A A s E un aaa a nay uama nn maana 24 7 3 Prograrmmiigi uuu uuu u a aE E a EEEa S 24 Re eN oo a E E E EA EE 24 2 Filtrate volume flow display a a 24 3 Input of the module s serial key a 24 ey NIL T u uu sS EEA uuu EE S sensei E E AAT 25 5 Set flush mode and minimum Filtration duration a a 25 1 Setting the contamination dependent cleaning 26 2 Selling a Qay ll Silnhguu uuu u k uuu E AE EEEE AEAEE 27 S ii i uuu asna PEAR A ENEA T nan 27 4 Delaying of flushing during water usage 28 PFOP atl Lu unum us ux aaa as u ns aan 28
33. ovider authorized to perform service e to a part that has been modified to signi ficantly alter functionality or capability without the written permission of Seccua f to consumable parts such as filter modules unless damage has occurred due to a defect in materials or workmanship or g if any serial number has been removed or de faced TO THE EXTENT PERMITTED BY LAW THIS WARRANTY AND REMEDIES SET FORTH ABOVE ARE EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES REMEDIES AND CONDITIONS WHETHER ORAL OR WRITTEN STATUTORY EXPRESS OR IMPLIED AS PERMITTED BY APPLICABLE LAW SECCUA SPECIFICALLY DISCLAIMS ANY AND ALL STATUTORY OR IMPLIED WAR RANTIES INCLUDING WITHOUT LIMITATION WARRANTIES OF MERCHANTABILITY FITNESS FOR A PARTICULAR PURPOSE AND WARRANTIES AGAINST HIDDEN OR LATENT DEFECTS IF SECCUA CANNOT LAWFULLY DISCLAIM STATUTORY OR IM PLIED WARRANTIES THEN TO THE EXTENT PERMITTED BY LAW ALL SUCH WARRANTIES SHALL BE LIMITED IN DURATION TO THE DURATION OF THIS EXPRESS WARRANTY AND TO REPAIR OR REPLACEMENT SERVICE AS DETERMINED BY SEC CUA IN ITS SOLE DISCRETION No Seccua reseller agent or employee is authorized to make any modification extension or ad dition to this warranty TO THE EXTENT PERMITTED BY LAW SECCUA IS NOT RESPONSIBLE FOR DIRECT SPECIAL INCIDENTAL OR CONSEQUEN TIAL DAMAGES RESULTING FROM ANY BREACH OF WARRANTY OR CONDITION OR UNDER ANY OTHER LEGAL THEORY INCLUDING BUT NOT LIMITED TO LOSS OF REVENUE LOSS OF ACTUAL O
34. play Diff Pressure 1 Setting language The system can be operated both with a German as well as an English menu display 2 Units time format time of day water temperature Similar to the above described procedure the units time format time of day and water temperature can be set Start Key Result Display examples Flow 0 0 gom Arrow key down Until Settings is shown Enter Display Language Enter Display German Arrow keys Choose English or German Enter Saves the selected language 3 Factory settings This function resets the system back to the factory settings Doc Rev 19122011 Page 29 oY SCCCUG UrSpring Ultrafiltration Unit Start Key Result Display examples Flow 0 0 gom Arrow key down Until Settings is shown Enter Display Language Arrow key down Until Set Default is shown Enter Display Set Default YES Arrow keys Select YES or NO Enter Confirms the selection 4 Calibration With this the analogue sensors of the system pressure sensors in the feed and filtrate are calibrated Return the system to an absolutely pressure less state before performing the calibration for instance by manually blocking the feed as well as the filtrate line and performing a manual rinse as described in chapter 5 9 Flushing and Commis sioning During the flushing the pressure in the system is equalized with the atmospheric pr
35. qtastanmassaqussuyasosusspusmusaasau 16 2 Mounting with screwed connections a 16 3 Mounting with speedfit couplings 16 2 AO INNS e u uuu uuu nan 17 Tillie uuu sn 2 EE ETE E asa a 17 I Diri ee n ee u m s us 17 5 9 Flushing and Commissioning J J u Q Q J 18 STS e cee u s u uuu E E O nu u s 18 2 Flushing of the system a a arar rsssrsssssaaa 18 OO l Oi qu sarees cepa E E E E E S E O 18 Doc Rev 19122011 Page 3 oY SCCCUG UrSpring Ultrafiltration Unit 6 Operating States u J J T 19 6T FISON u u uuu u u u u u us 19 6 CS ANNI casei we u E x 19 6 3 Emergency operation mode u u LIL IIIISIiIS a suikasiiskawaaukipukiuqwankawkiuaqayaqapupa 20 6 4 Sterilization of the system e g after standstill 20 7 Control ANd Programiniligu LULU u 21 7 1 Control panel of the control unit U 21 DOV EI VIG WY EVI OA luu u u E EE E 21 2 LED lights and col
36. r is required in order to discharge the water accumulating during flushing Please note that the nominal size of the drain line should correspond to the feed line pressure and type of system When routing the drain line it must be ensured that no back flow of any type can form Therefore route the drain line without any unnecessary bends and use adequately dimensioned pipe Doc Rev 19122011 Page 17 amp SCCCUG UrSpring Ultrafiltration Unit An open separation must be provided between the system drain and the drain line in order to prevent re contamin ation of the system due to drain water free drain in accordance with DIN 1988 Part 4 Design Classification A as per European Standard EN1717 5 9 Flushing and Commissioning 1 General Before commissioning of the system please first ensure that all impurities are removed from the connection lines in order to avoid damage to the membrane and to guarantee a maximum filtrate quality It must be ensured that the unit is installed in a germ free pipeline network and that no impurities are found in the water downstream of the system If necessary the pipeline network between the system and the consumers must be disinfected The systems are treated with a natural food preservative solution Sodium bisulfite at the factory This must be rinsed out before commissioning of the system Pay attention that no metal or plastic turning or oil residue remains in the connection li
37. rmance data J J J U cud U U U U Q 38 11 2 Ultrafiltration module J J J U U U U U Q 38 Doc Rev 19122011 Page 5 oY SCCCUG UrSpring Ultrafiltration Unit 1 User Information 1 1 General The ultrafiltration UF installation simultaneously removes turbidity and pathogens from water supplied from surface spring or well water sources Cost efficiently without the use of chemicals or radiation The fully automated conditioner uses extra rugged certified ultrafiltration membranes with pore sizes of less than 20 nanometers 1 000 times smaller than those of a conventional micro filter the pores in the membrane nearly completely remove viruses bacteria and legionella from all types of raw water 1 2 Guarantee Conditions Please read the guarantee conditions carefully You can find these in the chapter Limited Warranty at the end of this user manual as well as in the general terms and conditions of the manufacturer This system left our facilities complete and in functioning condition Please check the unit immediately upon receipt for completeness and pos sible shipping damage If the system or parts of the system have been damaged during transport notify the transport company immedi ately Transport damage to the system is not covered by the guar
38. rtain monitoring functions 1 Operation The display has a line in which the relevant menu item or the values to be entered are displayed After switching on connection with the mains plug the control unit shows the filtrate volume flow display The control unit continu ously monitors and measures the volume flow the feed and the filtrate pressure Conclusions about filter fouling and system output can be drawn from these values 2 Menu structure of the control unit See next page If you have a UrSpring without the Dura Kit option some of the settings are meaningless as there are no sensors that are necessary to calculate a differential pressure and fouling Page 22 Doc Rev 100410 SCCCUG UrSpring Ultrafiltration Unit ua ss JOU ISO q p yay 10113 aaa a ara prra _ wwwra _ syinejyap 10 98 io Jueujsnipy o suejeuuesed 00 00 uiw 19S ur IAN uguu 9S aqua pue Buryesedo 19S s y moe Buisn po5 Jati Jl 1 1u3 fellas 1IBip 6 1 u3 yoeg i lu3 Shay mouy ha shay mony a S y mony 1eua eee _ ON SS A 1 PAA JOOUUODSIG equNN 7 nead 18S 00 00 4noy 18S wid we yeueduy usii6u3 19 U 19444 A Jou A A Jo u A 1 1ud y5eg 1 lu3 103 yoeg i lu3 a yoeg i lud yoeg i lu3 uq y92eg 19 443 J yoeg io Uy a y5Seg i lu3 mou lelqilEO lt p Kay eves p InjsqiS SUL 38S lt q gt pwug wy a suun lt
39. s 1 Connections M12 Connector Power electrical connection oF Filtrate Drain Diagram 4 View of the left hand Diagram 5 View of the right hand side side with the feed connection with filtrate and rinse water connection The connections in the connection block are carried out as 3 4 internal threads metric The connection block is made of plastic The system is delivered with speedfit coupling adapters 3 4 external thread to pipe with 22 mm outer diameter Before connecting the system with the pipeline network any turning and other sharp edged residue must be re moved from the pipework in the feed of the system in order to prevent damaging of the membranes 2 Mounting with screwed connections 1 The connection block of the system is made of plastic Ensure that the internal thread of the connection block is not damaged during installation of the component with the screwed connection 2 Only use pipes or fittings with a 3 4 metric external thread for screwing into the block 3 Only use Teflon string Teflon tape or liquid Teflon for sealing the pipe that is to be connected Do not use hemp which swells up in contact with water and can lead to damage of the block or organic grease 4 Pay attention to the maximum thread reach 15 mm 3 Mounting with speedfit couplings 1 First screw the quick couplings into the connection block The couplings seal against the block by means of an O ring Therefore the entire t
40. stance necessary in houses which are not inhabited continuously in order to prevent water standing in the filter 3 However not before a minimum filtration length which can be set has expired this is important or else strongly contaminated filters would be be flushed continuously 4 Not if water is being used e g when a person is taking a shower this function can be suppressed when the systems are for instance utilized in the inlet of an overhead tank Flushing is then delayed until the wa ter usage is turned off If you have a UrSpring without the Dura Kit option you can only do a cleaning cycle at one time of day 6 2 Cleaning During the cleaning of the system the membrane is flooded no water flow takes place through the membrane Flushing should last about 10 seconds and the highest possible flow speed should be achieved Usually it is suffi cient when the feed pressure which is present during filtration is also used as the driving force during flushing Doc Rev 19122011 Page 19 amp SCCCUG UrSpring Ultrafiltration Unit Generally speaking the more turbid the raw water the more frequently the membranes must be rinsed Important With the correct settings the system will adapt to fluctuating water qualities 6 3 Emergency operation mode If a fault occurs in the system caused by excessive trans membrane pressure the system switches into the emer gency operation mode and the flush valve opens automati
41. t 107 Ambient temperature below 0 C 32 F Make sure that water does not freeze The electronic control will work also below 0 C 108 Excessive trans membrane pressure TMP gt Seek for the cause of the possible exceeding 2 5 bar 36 26 psi risk of filter damage of the pressure difference This may not ex ceed a pressure difference of 2 5 bar 36 26 psi between the feed and filtrate side at maximum water consumption The sensors are not functioning correctly Contact your service technician The valve does not switch The power connection is faulty Verify that the power cable mains plug is con the display remains dark nected and inserted properly The control unit is defective or the software on Replacement of the control unit cover or your system has an error flashing of functioning software by your ser vice partner The valves of the system were not connected Have an authorized installer or electrician con correctly with the control unit cover nect the valve with the control unit cover No water comes from the fil Blocking device in the feed line to the system if Open the blocking device trate outlet installed closed Malfunction of the valve of the system or an Verify the function of the valve If necessary alarm occurrence which has led to a perman have this replaced by your service partner ent opening of the drain valve Check whether an alarm has occurred in the system If this is the case
42. tance being used for filling a storage tank as this would suppress a flushing permanently in the case of continuous volume flow Flushing is delayed until water usage is stopped Start Key Result Display examples Flow 0 0 gpm Arrow key down Until Flush mode is shown Enter Display Clean at fouling Arrow keys Until the display of Flush when flow Enter Display Set NO Arrow keys Changing the status Enter Setting is saved Display Flush when flow 6 Operating data 1 Display of the filter status Start Key Result Display examples Flow 0 0 gom Arrow key down Until Operating Data is shown Enter Display Filter State Enter Display of the filter state in of the fil ter performance in regard to the new condition of the filter This value is first recorded after the first cleaning Enter Return to the menu Operating data Display Filter State Page 28 Doc Rev 100410 2 Pressure difference display 7 Settings ts SCCCUC UrSpring Ultrafiltration Unit Start Key Result Display examples Flow 0 0 gpm Arrow key down Until Operating Data is shown Enter Display Filter State Arrow keys Until Diff Pressure is shown Enter Display of the pressure difference feed pressure minus filtrate pressure directly at the membrane filter Unit is bar or psi Enter Return to the menu Operating data Dis
43. the cover A under the valve block and securely connected to it 14 Carry out a cleaning of the system 15 You can now take the system back into operation Doc Rev 19122011 Page 33 oY SCCCUG UrSpring Ultrafiltration Unit 9 Troubleshooting 101 The emergency flush is running or has run This Seek for the cause of the possible exceeding alarm is activated when the maximum permiss _ of the pressure difference This may not ex ible membrane pressure is exceeded in order to ceed a pressure difference of 2 5 bar 36psi avoid damage to the membrane between the feed and filtrate side at maximum water consumption 102 Permeability is too low Contact your service technician 103 Info that the filter should be changed soon Prepare the replacement of the filter if re quired order a replacement filter 104 Indicates that the last cleaning could not raise Check the set minimum filtration length as well the performance of the filter above the set as the threshold value at which a cleaning is threshold value for cleaning triggered If required shorten the minimum fil tration length to 20 minutes and set the threshold value to 60 It should be possible for the system to then incrementally regain its performance in the course of the next days 105 Problem with power supply Check the power supply and socket 106 Ambient temperature above 40 C 104 F Take measures to lower temperature in ambi ent of uni
44. the new module and screw this fin ger tight max 5Nm from above with four cylinder head screws onto the end cap The module B should now be seated tightly on the end cap C and be fastened securely to it 10 Now loosen the four cylinder head screws one after another with an Allen key for M8 on the clamps in the upper surrounding groove of the old module B which joins it with the valve block A Page 32 Doc Rev 100410 s SCCCUC UrSpring Ultrafiltration Unit Warning The ultrafiltration module can weigh up to approx 10 kg 22 Ib The weight of the module must be secured when the screwed attachment between the module and the valve block is loosened 11 Remove the old ultrafiltration module from the system and ensure that the O ring part no 10549 which is placed in the groove of the valve block underside is not lost This remains on the valve block and is reused for the new filter module as long as it is not damaged 12 Insert the new filter module B with the end cap C mounted earlier centrally in the valve block A from below Carefully push the module upwards to a dead stop Ensure the correct position of the O ring seal 13 Place the two clamps in the surrounding groove on the upper side of the new module and screw this fin ger tight max 5Nm from the bottom with the remaining four cylinder head screws onto the valve block A The new module B with the end cap C should now be seated tightly against
45. tion Unit 3 Operating Conditions and System Layout 3 1 Operating data of the system Max operating pressure 5 0 bar 500 kPa 73 psi Operating temperature 4 C to 40 C 39 F to 104 F Water temperature 4 C to 40 C 39 F to 104 F hot water variant 60 C 140 F Storage temperature temperature 0 C to 40 C 32 F to 104 F pH range pH value of 1 to 13 during cleaning pH value of 2 to 11 during operation Chlorine tolerance In regard to free chlorine Total loading 200 000 mo l xh 200 mg l max concentration Pressure difference feed filtrate 0 max 2 5 bar 250 kPa 36 psi Separating limit g mol or Dalton 100 000 150 000 Cleaning method Manual and automatic flushing time interval con trolled or dependent upon the degree of contamina tion through monitoring of the pressure difference and volume flow Note See further details about system performance in the appendix starting on page Fehler Referenz nicht gefunden 3 2 System layout 1 Pressure shocks Rapidly closing valves piston pumps and vertical pipe layouts can cause damaging pressure shocks These in turn can lead to filter damages in the membrane damage to the pipeline network the membrane itself as well as the seals and additionally can cause deviations to system dimensions Pressure shocks normally occur through rapid starting stopping or changes in the direction of flow Any of these causes can lead to
46. ush daily at is shown Enter Display Set hour 00 30 Arrow keys Setting the time of day at which a clean ing is performed First the hours are set via the arrow keys Enter Ends the entry Display Set minutes 00 30 Arrow keys Setting the minutes via the arrow keys Enter Ends the entry and jumps back to the menu Flush Mode Display Flush daily at Arrow key down Until Daily OFF is shown 3 Setting flush time Doc Rev 19122011 Enter Display Daily OFF Arrow keys Switch between ON and OFF Enter Ends the entry and jumps back to the menu Flush Display Daily ON Start Key Result Display examples Flow 0 0 gom Arrow Key down Until Flushmode is shown Enter Display clean at fouling Arrow Key down Until Flush length is shown Enter Display 20 Seconds Arrow Key up Flush length increases Arrow Key down Flush length decreases Enter Setting is saved Display Flush length Page 27 oY SCCCUG UrSpring Ultrafiltration Unit 4 Delaying of flushing during water usage With this function it can be avoided that flushing is performed during water usage and in this manner the water flow is interrupted It is recommended to activate this function only when the system is installed in the direct inlet of a house or an apartment This function must be deactivated when the system is for ins