User`s Manual PGT 120
Contents
1. Installation The Unit is for desktop or wall mounting The optionally available wall mounting frame Part No 7100 PGT100 101 can be used to fix the unit to a wall The power is either supplied by a 9V battery or by a power supply Insert the batteries by opening the battery compartment flap on the bottom side of the unit Take care of the proper polarity Close the battery compartment flap again It is strongly recommended to remove old or empty batteries to avoid battery leakage For heavy use or footwear in series mode we recommend using the external power supply Use only an original power supply connected to the AC12V socket on the rear On plugging in external power the internal battery is disconnected The battery should be removed to avoid wear out Do not connect any conducting articles with PGT120 except original accessories power supply battery and foot wear electrode and the door opener Connect the foot electrode with the coloured marked plugs to the back of the unit for footwear test Page 4 of 13 V0108 PGT 120 User s manual from SN 00260 up Part No 7100 PGT120 Wolfgang Warmbier Systeme gegen Elektrostatik Operation This tester has no power switch Pressing an electrode or activating footwear in series activates the electrical circuit The measuring voltage is preset to 100V Use the DIP switches 4 5 to adjust the voltage to either 30V or 50V Refer to the DIP switch configuration table on
2. EA o c o Q O o O Q Page 13 of 13 sockets for foot electrode Dip Switch socket for door opener socket for external power supply Wolfgang Warmbier Systeme gegen Elektrostatik V0108
3. page 8 Wrist strap test Settings Only wrist strap or OR is activated DIP switch 1 2 Put on the wrist strap and connect it via a coil cord to the snap or to the socket on the left side of the unit Press the left electrode and keep it pressed A peep signal indicates the start of measurement After a short measuring time the result is displayed OK Green LED flashes The measured value is o k mm Red LED flashes a Hi Fail audible signal Above the resistance upper limit Lo Fail Red LED flashes Below the resistance lower limit audible signal not applicable if lower limit is disabled Release the electrode Coil cord test A amp SES Settings Only wrist strap or OR is activated DIP switch 1 2 To check only the coil cord connect the coil cord to the 3mm snap located inside the wrist strap symbol and to the 10mm snap or socket on the left side of the unit Press the left electrode and keep it pressed A peep signal indicates the start of the measurement After a short measuring time the result is displayed OK Green LED flashes The measured value is o k PS Red LED flashes f 2 Hi Fail audible signal Above the resistance upper limit Lo Fail Red LED flashes Below the resistance lower limit audible signal not applicable if lower limit is disabled Release the electrode Footwear test single shoe 4 Settings Only footwear or OR is activated DIP switch 1 2 Page 5 of 13 V0108 PGT 120 User s
4. User s Manual PGT 120 From Serial No 00260 up Wolfgang Warmbier Untere GieBwiesen 21 D 78247 Hilzingen www warmbier com PGT 120 User s manual from SN 00260 up Part No 7100 PGT120 Wolfgang Warmbier Systeme gegen Elektrostatik Table of contents Page 2 of 13 V0108 PGT 120 User s manual from SN 00260 up Part No 7100 PGT120 Wolfgang Warmbier Systeme gegen Elektrostatik Introduction The Personnel Grounding Tester PGT 120 is an electronic test instrument for checking personnel grounding systems such as wrist straps coil cords and footwear The PGT120 is suitable for compliance verification of the above products according to the IEC 61340 5 1 Edition 1 0 2007 08 or ANSI ESD S 20 20 2007 2007 03 The unit operates with 3 independent measuring circuits for the left shoe the right shoe and the wrist strap This makes it possible to measure all the values at the same time It is possible to enable or disable separately the measuring circuits The order of tests is random Footwear measurement can be configured to measure in series with hands free for passenger gates Visual and audible test results and a dry relay contact for door opener Use the optionally available Calibration Unit Part No 7100 PGT120 CU to check the unit Hi and Lo limit values Page 3 of 13 V0108 PGT 120 User s manual from SN 00260 up Part No 7100 PGT120 Wolfgang Warmbier Systeme gegen Elektrostatik
5. bled Release the electrode The OK signal only appears when all measured values are within the limits Footwear in series 4 gt Settings Footwear in series activated DIP switch 6 The footwear test can be accomplished hands free without touching a electrode This is useful in combination with passenger handling gates The resistance is measured between the two shoes This mode cannot directly indicate the faulty shoe Press the Shoe electrode on the instrument to identify it Page 6 of 13 V0108 PGT 120 User s manual from SN 00260 up Part No 7100 PGT120 Wolfgang Warmbier Systeme gegen Elektrostatik Stand with both feet onto the foot electrode If the shoes are dissipative the measurement starts automatically with a peep signal After a short measuring time the result is displayed and the connected gate will open OK Green LED flashes The measurement of the footwear in series is o k Hera Red TED Tasten Above the resistance upper limit for series connection audible signal Lo Fail Rote LED flashes Below the resistance lower limit audible signal not applicable if lower limit is disabled You can step of the foot electrode Even if footwear in series is active you can perform a test according chapter to chapter 0 by pressing a electrode for example to identify a bad shoe Page 7 of 13 V0108 PGT 120 User s manual from SN 00260 up Part No 7100 PGT120 Wolfgang Warmbier Systeme gegen E
6. en Elektrostatik Wall mounting instructions Part No 7100 PGT100 101 Fix the wall mounting plate with the supplied dowels and screws and stick the self adhesive Velcro tapes according to the picture 1 The surface of the plate and the bottom side of the PGT120 have to be clean dry and free of grease 2 Remove protecting foil of the velcro tapes and do not touch the sticky side 3 Apply the velcro tapes according to the picture onto the mounting plate 4 Remove the second protecting foil of the velcro tapes and press the PGT120 against them 5 After 24 Hour curing time the PGT120 can be removed from the wall mounting plate Before removing the unit please unplug all wires Hold the unit on both sides and pull it forwards To fix it again press it back onto the velcro tapes Wall mounting plate ca 10mm velcro tape Page 10 of 13 V0108 PGT 120 User s manual from SN 00260 up Part No 7100 PGT120 Specifications Operating voltage Operating conditions Storage conditions Connectors Measuring ranges selectable Test voltage Signals Contact ratings Operating modes Weight Dimensions Serial number 9V E 6F22 battery Wolfgang Warmbier Systeme gegen Elektrostatik external power supply 230V 50Hz 15 40 C 10 60 C Wrist strap Foot electrode Door opener up to 75 relative humidity non condensing up to 85 relative hu
7. lektrostatik Configuration The unit can be configured with the DIP switches on the rear according to the table below Standard settings are marked bold Switch 1 Switch 2 Test mode OFF OFF OR wrist strap or footwear test ON OFF Only footwear test OFF ON Only wrist strap test ON ON AND wrist strap and footwear test Switch 3 Footwear upper limit OFF 35 MQ for single shoe 70 MQ for series ON 70 MQ for single shoe 140 MQ for series Switch 4 Switch 5 Test voltage OFF OFF 30 V OFF ON 50V ON ON 100 V Switch 6 Footwear test mode OFF test according to switch 1 2 ON footwear in series active Switch 7 Lower limit OFF Lower limit disabled ON Lower limit enabled Switch 8 Door opener OFF inactive ON active Page 8 of 13 V0108 PGT 120 User s manual from SN 00260 up Part No 7100 PGT120 Wolfgang Warmbier Systeme gegen Elektrostatik Connectors The connectors for the power supply the foot electrode and the door opener are located on the rear side of the unit Use a RJ12 western modular plug to connect the dry contact of the door opener The door opener relay is triggered and stays on for 3 seconds when the test result indicates OK This function must be enabled with DIP switch 8 Normally Open Pin 3 4 Normally Closed Pin 2 3 123456 Contact function Connector view 123456 Door Opener Page 9 of 13 V0108 PGT 120 User s manual from SN 00260 up Part No 7100 PGT120 Wolfgang Warmbier Systeme geg
8. manual from SN 00260 up Part No 7100 PGT120 Wolfgang Warmbier Systeme gegen Elektrostatik Stand on the foot electrode then press the right electrode and keep it pressed A peep signal indicates the start of measurement After a short measuring time the result is displayed OK Green LED flashes The measured values of both shoes are o k Hi Fail Red LED flashes right audible signal Hi Fail Red LED flashes Right shoe above the resistance upper limit Left shoe above the resistance upper limit left audible signal Lo Fail Red LED flashes Right shoe below the resistance lower limit right audible signal not applicable if lower limit is disabled Lo Fail Red LED flashes Left shoe below the resistance lower limit left audible signal not applicable if lower limit is disabled Release the electrode Wrist strap and footwear test amp n a 4 Settings AND function is activated DIP switch1 2 Put on the wrist strap and connect it via a coil cord to the snap or socket on the left side of the unit Stand on the foot electrode then press one electrode and keep it pressed A peep signal indicates the start of measurement After a short measuring time the result is displayed OK Green LED flashes All measured values are o k Red LED flashes Hi Fail Above the resistance upper limit audible signal Lo Fail Red LED flashes Below the resistance lower limit audible signal not applicable if lower limit is disa
9. midity non condensing 10mm snap 4mm snap 4mm socket 2 sockets 4mm Western socket 6 pin RJ 12 external 12VAC power supply Use only for the original power supply supplied with the instrument Wrist strap Footwear each shoe Footwear in series Tolerance open circuit voltage Green LED Rote LED s and buzzer Door opener Door opener time max voltage max current max power Single test OR Double test AND Only wrist strap test Only footwear test Hands free Mode app 500g 150 x 200 x 63 mm On the side of the unit Complies with CE Page 11 of 13 750kQ 35MQ 00 35M9 100kQ 70MQ 00 70MQ 100kQ 35MA OQ 35MQ 200kQ 140MQ 00 140MQ 200kQ 7OMQ 00 70MQ Hands free Mode 10 30V 10 50V 10 100V 10 OK Hi Fail or Lo Fail Dry contact OK 3 seconds 60V 2A 50 VA V0108 PGT 120 User s manual from SN 00260 up Part No 7100 PGT120 Wolfgang Warmbier Systeme gegen Elektrostatik Pictures sa Je9 A100 159 deus SUM 159 deus ISIM JO 8P0 1199 9 10 9P0 1199 9 JO Suonoouuoo Hull y Ul enj eA peinseew aal JI MO MOJ9Q qa pepeeoxe yw j jeddn qa S9 JE9M 00J wwe deus sjew ut UU MO MOJOQ qal pepeeoxe yw j 1eddn qal 159 deus ISIM V0108 Page 12 of 13 PGT 120 User s manual from SN 00260 up Part No 7100 PGT120 SIW MO N Jeuedo 100p co