Home

Scoria Bio Installation manual

image

Contents

1. o User manual Installation manual nexus your access LO SUCCESS Biometric Readers Bio Bio SW BioE Product concept Bio and Bio SW is a Biometric reader with adjustable Wiegand Output and can be connected to most Access Controllers with Wiegand interface BioE is a desktop USB biometric reader used for fingerprint enrollment Bio and Bio SW is a surface mount product Bio and BIOSW operate with fingerprint only Connection between the biometric readers is RS485 and it is used for finger print transfer and configuration nexusgroup com contact nexusgroup com Scoria Bio and Bio SW When used with third party controllers the connection between the Biometric readers and the PC is done through a converter CNV100 RS485 to RS232 or CNV200 RS485 to USB or CNV300 RS485 to TCP IP Only one converter is needed per system one converter for 1 2 3 30 31 Biometric readers Configuration of the readers and finger print enrollment is done through PC Software The Biometric Readers can be used with EX8 as standalone access control system or as readers with access control panels o User manual Installation manual nexus your access LO SUCCESS 2 Product Description 2 1 Bio and Bio SW Features O Surface mount biometric reader with capacitive sensor Bio SW has got a swipe sensor Adjustable Wiegand protocol 8 to 128 bit is utilized in the biometry
2. reader which makes it compa tible with other controllers with a Wiegand interface Only fingerprint operation Storage capacity 9000 fingerprints Configuring the system and Finger print enrollment is done through PC locally or remotely Enrollment can be also done from a Desktop Reader BioE Technical Specifications 00 000 Authentication Finger Template capacity 9000 Finger enrollment time lt 1 second for each finger Recognition and matching time lt 1 second for each finger Number of templates for each user 1 10 Templates Fingers Output Wiegand 8 128bit default Wiegand 26bit Communication RS485 Power Supply 12Vdc Consumption 70mA max Weight 200g IP factor Bio IP 44 Bio SW IP 65 Operating temperature 20 C 50 C nexusgroup com contact nexusgroup com Scoria Bio and Bio SW Buzzer sound level adjustment through PC Two free tension LED Wiegand Protocol adjustment is done through PC Separate BioManager Software available free when used with third party controllers The Fingerprints are stored in the reader and a backup copy is kept in the software Elegant aluminium housing in different colours 92mm ENorF User manual Installation manual he XS your access to success Scoria Bio and Bio SW Bio SW Red mmm 12V O Black GND Power Supply Pink m A RS 485 Tricolour LED idle mode Violet 5 J Gray Sa tamp J Timo
3. Add user Atuser table click on the last empty user field and enter user name B lromsmn a5 E oo o bo Click on ID User code field and enter ID number This number will be sent by the reader to the access controller when user finger is recognized by the reader Click on PIN code field and enter the PIN PIN code is used at readers with keypad When PIN code is typed at reader User ID will be sent to the access controller 8 6 Edit user Find user at user table to edit Click on the user field for edit Name ID or PIN Type new value Press Enter on the keyboard Important When ID is changed a warning message is displayed reminding that if ID exists in some readers it should be deleted from reader prior to change 8 7 Delete users Check the users to be deleted Right click on the users table Click on Delete checked users menu nexusgroup com contact nexusgroup com Nor7 User manual Installation manual nexus your access to success Scoria Bio and Bio SW 8 8 Enroll fingers Select the User in the User Column not the check box the check box is for sending the fingerprints and the User name cell will turn blue Select the Biometric reader or Desktop reader BioE from where the enrollment will be done Swipe the finger on the Reader and the fingertip will become blue with percentage of successful enrollment given right beside the fingertip No
4. Blue mmmE tamp p Green mE LG Green LED Orange LR _ Red LED Yellow IE D1 White po Wiegand orange finger not accepted red and finger accepted green Fingerprint Capacitive swipe Sensor Free Tension LED Red Green tG In idle mode the free tension LED is orange G TT gnd LR When access is granted the free tension LED is Green T When Access is denied the free tension LED is red Orange Idle Mode LG and LR not connected Green LG green wire connected to Note There are no terminal blocks in EX8 for the free eee tension LED When Bio SW is connected to EX8 the Red LR orange wire connected to GND tricolour triangle LED gives the access status No Hehe LC rennir and Dit orange wire connected to GND 2 2 BioE Features BioE is used when the enrollment needs to be done from somebody s Desktop Biometric reader USB powered desk It is not necessary to have BioE in Used only for fingerprint enrollment the system The enrollment can be done from any installed biometric reader nexusgroup com contact nexusgroup com ENor7 User manual Installation manual nexus your access to success Scoria Bio and Bio SW 3 Enrollment OO 4 Authentication The tricolour LED has three colour statuses Important Note During user authentica Orange Green amp Red It operates only on tion the finger must be swiped in the same fingerprint en
5. and with the PC Software through a Converter The RS485 Line should be configured in the form of a daisy chain NOT in a form of a star Keep the stubs from the RS485 backbone as short as possible not more than 3 meters Converter Types CNV100 Rs485 to Rs232 CNV200 Rs485 to USB CNV300 Rs485 to TCP IP Wiring Configuration applies to all converters Bio and Bio SW RS 485 A Converter lesen PIN 1 RS 485 gt PIN 2 RS 485 7 Konverters PIN beskrivning CNV100 PIN nexusgroup com contact nexusgroup com Converter RS485 to RS232 Does not require installation CNV200 Converter RS485 to USB Requires installation as USB serial device refer to CNV200 Manual The Drivers are located on the CD CNV300 Converter RS485 to TCP IP No installation IP address set through Internet Brow ser refer to CNV300 Manual ENorZ User manual Installation manual he Xus your access LO SUCCESS Scoria Bio and Bio 8 Configuring the Biometric Readers in BioManager BioManager is software for fingerprint management of PAS Card Biometric Features Fingerprint Enrollment It can be done by ANY Biometric reader in the network or by Desktop USB Bio metric reader Note The Desktop Biometric reader BioE is only compatible to Biometric readers with capacitive sensor not with the ones with thermal sensor Fingerprint
6. o neXus your access LO SUCCESS User manual Installation manual Scoria Bio and Bio SW Reader Scoria Bio and Bio SW Scoria Bio SW is a compact and stylish biometric reader for outdoor environment The reader is equipped with the latest in biometric technology which means that Scoria Bio SW has a capacitive silicon sensor that is tamper proof Biometric Reader Scoria Bio Scoria Bio SW nexusgroup com contact nexusgroup com Content 1 Product concept 2 2 Product Description 3 2 1 Bio and Bio SW 3 2 2 BioE 4 3 Enrollment 5 4 Authentication 5 4 1 Authentication of a user by a fingerprint 5 5 Mounting 6 6 Connecting Biometric Readers to Third Party Controller 6 6 1 Communication chain RS485 7 Converters PIN descriptions 7 8 Configuring the Biometric Readers in BioManager 8 8 1 Add Reader 8 8 2 Edit Reader 10 8 3 Delete Reader 10 8 4 Calibrate sensor 10 8 5 Add user 1 8 6 Edit user 1 8 7 Delete users 11 8 8 Enroll fingers 12 8 9 Upload fingerprint to readers 12 8 10 Delete fingerprints 13 8 11 Deleting one user from the biometric reader 13 8 12 Deleting all users from the biometric reader 13 8 13 Complex user upload 14 8 14 Custom Wiegand 14 9 Wiegand protocol description 15 9 1 Description for the 26 bits Wiegand format 16 10 Connecting the Biometric readers with EX8 controller 16 11 Safety precautions 17 12 Troubleshooting 17
7. Network portal Main entry Configure Flexibility Level Succes 28 03 2010 17 58 15 Network portal Main entry Save Flexbility Level Succes 28 03 2010 17 58 15 Network portal Main entry Configure parameters Succes nexusgroup com contact nexusgroup com C ors nexus your access LO SUCCESS 8 2 Edit Reader Right click on the reader and select Properties Main entry Check at event table if the configuration was successful TDTO 17 5816 Piese past ad Man ertey Cotpet Weged Succes 26 03 2010 17 5815 Netwah palal Menerty Corkgwe Fiti Levi Succes ONTO IF ERIS Neneh pid Menerty Seve Fentiiy Level Sustot TUVA 17 80 1 Peete pata Man eray orbep se pa setm succes 8 3 Delete Reader User manual Installation manual Scoria Bio and Bio SW Edit reader properties and click Save button Right click on the reader and select Upload configuration E Main entry w Right click on the reader and select Delete reader 2013 08 14 15 19 01 2013 08 14 15 18 41 2013 08 14 15 18 41 Ta bort lasare 8 4 Calibrate sensor Right click on the reader and select Calibrate See events panel to check Calibration flow It is recommended to do sensor calibration once after reader is mounted Clean the fingerprint sensor before calibration nexusgroup com contact nexusgroup com ENOo7F User manual Installation manual nexus your access to success Scoria Bio and Bio SW 8 5
8. The Biometric Reader becomes known to the EX8 controller as soon as they are linked No further configuration is required max 50 met gray Blye aMper ponnu Maximum cable length between EX8 and reader is 50 meters For programming please refer to EX8 User Manual nexusgroup com contact nexusgroup com o User manual Installation manual neXus your access LO SUCCESS 11 Safety precautions Do not install the device in a place subject to direct sun light humidity or dust When the device is mounted outside use the protective plastic cover ref ATP ATP MINI Do not install the device and cabling close to a source of strong electro mag netic fields like radio transmitting Scoria Bio and Bio SW Do not clean the device with any form of liquid Use soft and dry cloth only Be careful not to let liquid like water drinks or chemicals leak inside the device Do not let children touch the device without supervision Note that if the sensor is cleaned by detergent benzene or thinner the antenna Donot place the device near or above heating equipment s 12 Troubleshooting Observation The orange Led on the Biometric Reader is blinking all the time The keypad of the Biometric Reader is not working The finger scan in Bio SW works but the proximity does not work Enrollment from desktop reader can be done but the Fingerprints are not sent to all Biometric Readers in th
9. Transfer Finger templa tes can be sent to any Reader in the Network 8 1 Add Reader Right click on the portal connected to the reader and select Add reader A Network portal Fill the Reader form readers when used with third party access controllers Different Users can be sent to diffe rent Biometric readers PIN Codes management and trans fer PIN Code length configuration 1 to 8 digits and PIN Code transfer Wiegand Output Configuration The Wiegand output of the Biometric reader can be customized bitwise Click on Save and the reader icon appears under the selected portal Y ih mais Vis Minit portal P nexusgroup com contact nexusgroup com D 3 wll SW ENorF User manual Installation manual nexus your access to success Scoria Bio and Bio SW Right click on reader and select Version info Ifreader is online new line is added on top of the event table CAA SS Network portal Mainenty Device online Type Bior Version 1 22 Ifreader is not online following line is added on top of the event table 2013 08 14 15 19 00 CNV300 fBiolasare 1 Ingen respons Ifreader is online right click on reader and select Upload configuration re ewen ewe w P Main entrv Check at event table if configuration was successful line Patel Reader Event User a 28 03 2010 17 58 16 Network portal Main entry Configure Wiegand Succes 28 03 2010 17 58 15
10. e network The Biometric Reader is not powered ON The tricolour LED is OFF Fingerprint or PIN Code is recognized the tricolour LED is green but the controller reports other ID number and the access is denied Electro static discharge influences the fingerprint scan PIN Codes are working correctly finger scan does not work The tricolour LED is OFE Reader reading performance is decrea sed Fingerprint is not recognized normally nexusgroup com contact nexusgroup com surface will be damaged and the fingerprint can t be entered Action There were 15 unsuccessful attempts of authentication Finger or PIN The orange LED will turn off after the first accepted finger or PIN The operation mode of the Biometric Reader is set as Finger Please select Key code OR Finger mode The operation Mode of the Biometric Reader is set as Finger Please select Card OR Finger mode Check the serial number of the readers Check if proper termination is done as described In 6 2 Check if the communication wires A and B are properly connected to the reader Check the power supply red and black wire If the user is not deleted from the reader and the same user is enrolled again with new ID the reader will recognize the finger with the first ID To resolve this delete all users from the reader and upload all users to the reader Check the Wiegand Bus yellow and white wire Check if the g
11. ess Scoria Bio and Bio SW 8 13 Complex user upload Complex user upload is used to send multiply user selection to more readers e Click on Upload table at main menu Settings Upload table JEnglish Use mouse click to select the combination you need or use right click to check or clear entire row or column Select Upload Users to readers or Delete Users from readers Tien aiik at right click menu Asupload is progressing check boxes are cleared mining appropriate combination was successfully done When upload is over if there are still checked items repeat the upload command 8 14 Custom Wiegand BioManager has defined Wiegand 26 and 34 bit as standard options and three other Wiegand settings as user definable To setup custom Wiegand format Select Wiegand menu from Settings At Wiegand setup window Custom 1 select one from customs Wiegand nexusgroup com contact nexusgroup com ENOorF User manual Installation manual nexus your access LO SUCCESS Set Wiegand parameters Scoria Bio and Bio SW Click on Save button Note Wiegand settings are out of scope for common end user Please ask your installer to set the parameters and do not change it later For more information please refer to BioManager User Manual 9 Wiegand protocol description The data is sent over the lines DATA 0 for the logic 0 and DATA 1 for the logic 1 Both lines
12. rollment and stays in an way asit was during the enrollment process orange state before authentication This increases the chance of a successful authentication 4 1 Authentication of a user by a fingerprint When swiping a finger the tricolour LED misread authentication for a valid user the turns green for one second and beeps twice tricolour LED turns red for three seconds if the user is valid For an invalid user ora together with multiple beeps nexusgroup com contact nexusgroup com G User manual Installation manual nevis your access to success Scoria Bio and Bio SW 5 Mounting Note The protective plastic cover 7 Mounting is recommended for all outdoor installations 6 Connecting Biometric Readers to Third Party Controller Third Party Controller Third Party Controller BioManager Connect the lines DO D1 Gnd and 12V to the third party Fingerprint enrollment is done from the PC Software controller Connection between the Biometric readers and the PC Connect the RS485 Line A B to the converter Connect must be established the converter in the PC Note The Biometric reader must be powered from the controller or make common ground for the controller and the Biometric reader nexusgroup com contact nexusgroup com User manual Installation manual Scoria Bio and Bio SW us your access LO SUCCESS 6 1 Communication chain RS485 The Biometric readers communicate with each other with a RS485
13. round of the controller and the Biometric Reader is the same Check if the length between Biometric Reader and the controller is less than 50 m Connect the housing of the Biometric Reader to the earth wire Fingerprint sensor malfunction Check the sensor position and its physical condition Reset the system Contact your installer Check if fingerprint reading area is dirty Do not clean the device with any form of liquid Use soft and dry cloth only Reading area is damaged If the damage is minor try to calibrate the sensor Retry after drying the wetness of your finger When your finger is too dry touch your forehead and try again When you have a cut on your registered finger register another fingerprint
14. te If more fingerprints are added for one user all fingerprints will send the same Wiegand Code to the controller 8 9 Ladda registrerat fingertemplat till l sare Check the users which fingerprints will As each user is being sent the checkbox be sent to the Reader will become unchecked indicating that the user is successfully sent In the same time the orange LED of the Biometric reader blinks Note Average time for transferring one Right click on the Biometric reader finger template is 0 6 sec The PIN Codes are those users should be sent and select also being sent if there are any Upload users S nexusgroup com contact nexusgroup com a 0 User manual Installation manual nexus your access to success Scoria Bio and Bio SW 8 10 Delete fingerprints After transferring the fingerprint is stored in the Biometric reader and in the PC Deleting can be done only in the software only in the readers or from the both places 8 11 Deleting one user from the biometric reader Select the user s checkbox Delete users The user is deleted from the reader but his fingerprints are still in the software s database They can be sent ones again without the need of reenrollment 8 12 Deleting all users from the biometric reader Right click on the Reader and select Delete all nexusgroup com contact nexusgroup com ENor7 User manual Installation manual nexus your access to succ
15. use inverted logic meaning that a pulse low on DATA 0 indicates a 0 and a pulse low on DATA 1 indicates a 1 When Code 0 0 DO 5v the lines are high no data is being sent Only 1 of the 2 lines DATA 0 DATA 1 can pulse at the same time Example data 0010 1 0 A i 4h Jh 75uS 1mS 754S D1 5V i Data bit 0 approximately 75 us microseconds Data bit 1 approximately 75 us microseconds Time between two data bits approximately 1 ms millisecond Both data lines D0 and D1 are high nexusgroup com contact nexusgroup com ENor7 User manual Installation manual nexus your access to success Scoria Bio and Bio SW 9 1 Description for the 26 bits Wiegand format Each data block consists of a first parity bit P1 a fixed 8 bits header 16 bits of user code and a 2nd parity bit P2 Such a data block is shown below Parity bit bit 1 8 bits header 16 bits user code 2 bytes Parity bit bit 26 Pl XXXXXXXX XXXXYYYY YYYYYYYY P2 Exempel 170 31527 1 10101010 01111011 00100111 0 Note Parity bits are calculated as follows P1 even parity calculated over the bits 2 to 13 X P2 odd parity calculated over the bits 14 to 25 Y BRB B DEER OB ODDO OO OREM IOs Odd Even Parity Site Code User Code Parity Bit Bit 10 Connecting the Biometric readers with EX8 controller When connected with EX8 controller the Biometric Readers are becoming Standalone Biometric readers

Download Pdf Manuals

image

Related Search

Related Contents

Staff Development & Performance Review: Operating Instructions for  Bedienungsanleitung Inhaltsverzeichnis  Actebis Exsys EX-44012 2P PCI-Express Parallel card  Katalog als PDF  VS Peco Manuale Utente  Sennheiser Mikroport-Solo SKM 4031 User's Manual  Bedienungsanleitung  OFISTAR H7300 はじめにお読みください  CEL-63x field guide FG45_FR.cdr  Hydro-Control V User Guide  