Home
USER MANUAL - Keene Electronics
Contents
1. 2 Getting Started We recommend that you e Unpack the equipment carefully and save the original box and packaging materials for possible future shipment e Review the contents of this user manual Use Kramer high performance high resolution cables Use only the power cord that is supplied with this machine Go to http www kramerelectronics com to check for up to date user manuals application programs and to check if firmware upgrades are available where appropriate 2 1 Achieving the Best Performance To achieve the best performance e Use only good quality connection cables to avoid interference deterioration in signal quality due to poor matching and elevated noise levels often associated with low quality cables e Avoid interference from neighboring electrical appliances that may adversely influence signal quality e Position your Kramer VA 50P away from moisture excessive sunlight and dust 210 VA 50P Getting Started 3 1 Overview The VA 50P is a 6 port 12V DC power supply It replaces up to 6 separate 12 volt adapters for Kramer TOOLS and other models that use 12V DC power adapters In particular the VA 50P e Is an efficient six outlet universal switching power supply that can output 12V DC with up to 500mA per output but not exceeding 2A total e ls designed to operate Kramer products that normally use an external 12V DC power transformer e Can be secured in a rack using the mode
2. Bar Audio Generator Connect the 12V DC OUTPUT 3 power outlet to the 72DV DC power inlet for example on a Kramer Pico Tools PT102VN unit Connect the 12V DC OUTPUT 4 power outlet to the 72DV DC power inlet for example on a second Kramer Pico Tools PT102VN unit Connect the 12V DC OUTPUT 5 power outlet to the 12DV DC power inlet for example on a third Kramer Pico Tools PT102VN unit Connect the 12V DC OUTPUT 6 power outlet to the 12DV DC power inlet for example on a Kramer Tools VP 100 unit 2 Connectthe power cord to the mains electricity PT102VN PT102VN PT102VN Figure 2 Connecting to the VA 50P VA 50P Connecting the VA 50P 5 Technical Specifications INPUT POWER SOURCE 100 240V AC 50 60Hz Pmax 42VA OUTPUTS 6 x 12V DC outputs maximum 500mA per output maximum 2000mA total current ACCESSORIES Power cord vertical stacking bracket 6 DC to DC cables OPTIONS RK 50RN 19 rack adapter Specifications are subject to change without notice at http www kramerelectronics com VA 50P Technical Specifications EI LIMITED WARRANTY We warrant this product free from defects in material and workmanship under the following terms HOWLONGIS THE WARRANTY Labor and parts are warranted for seven years from the date of the first customer purchase WHOIS PROTECTED Only the first purchase customer may enforce this warranty WHATIS COVERED AND WHATIS NOT COVERED Except as below this warranty covers al
3. KRAMER ELECTRONICS LTD USER MANUAL MODEL VA SOP Power Supply P N 2900 00601 2 Rev 4 Contents 1 Introduction 2 Getting Started 2 1 Achieving the Best Performance 3 Overview 3 1 Defining the VA 50P 4 Connecting the VA 50P 5 Technical Specifications Figures Figure 1 VA 50P Power Supply Figure 2 Connecting to the VA 50P N owownn Introduction Welcome to Kramer Electronics Since 1981 Kramer Electronics has been providing a world of unique creative and affordable solutions to the vast range of problems that confront the video audio presentation and broadcasting professional on a daily basis In recent years we have redesigned and upgraded most of our line making the best even better Our 1 000 plus different models now appear in 11 groups that are clearly defined by function GROUP 1 Distribution Amplifiers GROUP 2 Switchers and Matrix Switchers GROUP 3 Control Systems GROUP 4 Format Standards Converters GROUP 5 Range Extenders and Repeaters GROUP 6 Specialty AV Products GROUP 7 Scan Converters and Scalers GROUP 8 Cables and Connectors GROUP 9 Room Connectivity GROUP 10 Accessories and Rack Adapters and GROUP 11 Sierra Products Congratulations on purchasing your Kramer VA 50P Power Supply which is ideal for the following typical applications e Any audio video system using multiple 12V operated products e As a battery replacement for field battery operated equipment
4. icing
5. l RK 50RN kit that holds two VA 50P units and requires two vertical spaces in a standard 19 rack e Can save valuable space on power strips by replacing up to six wall transformers Make sure that the polarity of the connected unit matches that of the VA 50P that is the center pin is the positive terminal Defining the VA 50P This section defines the VA 50P OW Power Supply Max 500mA per output Max 2000mA total current 12V DC OUTPUTS Figure 1 VA 50P Power Supply Feature Function E POWER Switch Illuminated switch for tuming the unit ON or OFF 12V DC Power OUTPUTS Connect to the power inlet on a 12V DC unit from 1 to 6 Maximum 500mA per output maximum 2000mA total current Power Connector with FUSE Socket for connecting the AC power cord to the unit VA 50P Overview 4 Connecting the VA 50P Always switch off the power to each device before connecting it to your VA 50P After connecting your VA 50P connect its power and then switch on the power to each device To connect the VA 50P as illustrated in the example in Figure 2 1 Connect up to 6 power outlets using DC to DC cables as follows Six DC to DC cables are supplied with the VA 50P Connect the 12V DC OUTPUT 1 power outlet to the 12V DC power inlet for example on a Kramer FC 14 RGBHV to Component Transcoder Connect the 12V DC OUTPUT 2 power outlet to the 72DV DC power inlet for example on a Kramer Tools 810 Color
6. l defects in material or workmanship in this product The following are not covered by the warranty 1 Any product which is not distributed by us or which is not purchased from an authorized Kramer dealer If you are uncertain as to whether a dealer is authorized please contact Kramer at one of the agents listed in the Web site www kramerelectronics com 2 Any product on which the serial number has been defaced modified or removed or on which the WARRANTY VOID IF TAMPERED sticker has been torn reattached removed or otherwise interfered with 3 Damage deterioration or malfunction resulting from i Accident misuse abuse neglect fire water lightning or other acts of nature ii Product modification or failure to follow instructions supplied with the product iii Repair or attempted repair by anyone not authorized by Kramer iv Any shipment of the product claims must be presented to the carrier v Removal orinstallation of the product vi Any other cause which does not relate to a product defect vii Cartons equipment enclosures cables or accessories used in conjunction with the product WHAT WE WILL PAY FOR AND WHAT WE WILL NOT PAY FOR We will pay labor and material expenses for covered items We will not pay for the following 1 Removalor installations charges 2 Costs of initial technical adjustments set up including adjustment of user controls or programming These costs are the responsibility of the Kramer dealer from wh
7. lso have other rights which vary from place to place NOTE All products returned to Kramer for service must have prior approval This may be obtained from your dealer This equipment has been tested to determine compliance with the requirements of EN 50081 Electromagnetic compatibility EMC generic emission standard Part 1 Residential commercial and light industry EN 50082 Electromagnetic compatibility EMC generic immunity standard Part 1 Residential commercial and light industry environment CFR 47 FCC Rules and Regulations Part 15 Radio frequency devices Subpart B Unintentional radiators CAUTION IP Servicing the machines can only be done by an authorized Kramer technician Any user who makes changes or modifications to the unit without the expressed approval of the manufacturer will void user authority to operate the equipment Use the supplied DC power supply to feed power to the machine Please use recommended interconnection cables to connect the machine to other components FCC and CE approved using STP cable for twisted pair products Specifications For the latest information on our products and a list of Kramer distributors visit our Web site where updates to this user manual may be found We welcome your questions comments and feedback Web site www kramerelectronics com KRAMER E mail info kramerel com SAFETY WARNING Disconnect the unit from the power m supply before opening and serv
8. om the product was purchased 3 Shipping charges HOW YOU CAN GET WARRANTY SERVICE 1 To obtain service on you product you must take or ship it prepaid to any authorized Kramer service center 2 Whenever warranty service is required the original dated invoice or a copy must be presented as proof of warranty coverage and should be included in any shipment of the product Please also include in any mailing a contact name company address and a description of the problem s 3 For the name of the nearest Kramer authorized service center consult your authorized dealer LIMITATION OF IMPLIED WARRANTIES All implied warranties including warranties of merchantability and fitness for a particular purpose are limited in duration to the length of this warranty EXCLUSION OF DAMAGES The liability of Kramer for any effective products is limited to the repair or replacement of the product at our option Kramer shall not be liable for 1 Damage to other property caused by defects in this product damages based upon inconvenience loss of use of the product loss of time commercial loss or 2 Any other damages whether incidental consequential or otherwise Some countries may not allow limitations on how long an implied warranty lasts and or do not allow the exclusion or limitation of incidental or consequential damages so the above limitations and exclusions may not apply to you This warranty gives you specific legal rights and you may a
Download Pdf Manuals
Related Search
Related Contents
DKS Enterprises 1814 Telephone User Manual L`adjoint ou R1 et moi le R… TESTER-CCTV-P - AV DELICE SAHARA Showline SL 640 User Manual A185A Plasma Rocket Lamp User Manual Copyright © All rights reserved.
Failed to retrieve file