Home
Installation and Operation Manual
Contents
1. T munem A NEXUS A 1 2 NEXUS WIND Data NATIONAL NEXUS DISTRIBUTORS WARRANTY CARD INSTALLATION and OPERATION MANUAL 7 5 Mw 8 Pin e 11 13 2 INSTALLATION 1 Installation You can install the Nexus Wind Data in three different ways The wind transducer is connected directly to the Nexus Wind Data instrument By using the connection kit when both log and wind transducers are installed with a single Wind Data The installation may also include a Nexus Server where all transducers may be connected All data including power will pass along one cable The installation includes 6 major steps Read the installation and operation manual Plan where to install the transducers and instruments Run the cables Install the transducers and instruments Take a break and admire your installation Learn the functions and calibrate your system 9 9rdx co Before you begin drilling think about how you can make the installation as neat and simple as your boat will allow Plan where to position the transducers Server and instruments Think about leaving space for additional instruments in the future A few do nots you should consider Do not cut the cables too short Allow extra cable length at the Server so it can be disconnected for inspection without having to disconnect all N attached cables Do not plac
2. 36 PART SPECIFICATIONS 1 Part specifications Nexus Wind Data is delivered with all parts for mounting Check prior to installation Wind Data instrument Qty Description Reference 1 Instrument Nexus Wind Data 1 Instrument front cover 1 Drill template 1 Installation and user manual 1 Warranty card 1 National distributors list 1 Power cable red and black 3 m 9 ft 5 Extra wire protectors 0 25 mm 1 100 5 Extra wire protectors 0 75 mm 1 32 4 Mounting screws for the instrument 4 Round rubber covers 1 Tube of silicon grease 1 Connection cover 2 4 pol screw terminal Additional Wind Data complete with transducer Wind transducer Nexus 10 Mast top cable 25m 83 ft 11 Mounting screws for mast bracket 12 Mast head bracket 13 o 0848 Registering of this product Once you have checked that you have all the listed parts please take time to fill in the warranty document and return it to your national distributor By returning this document it will assist your distributor to give you prompt and expert attention in the event of your experiencing difficulties with this product Keep your proof of purchase Also your details are added to our customer database so that you automatically receive new product catalogues as and when they are released PART SPCIFICATIONS
3. 27 5 4 6 C63 Speed reference water or 5 28 5 4 7 C64 Wind trim reference 28 5 4 8 668 Roll adjustment ntes Cr tied tor trea dd ke ie d B aos 28 5 4 9 C69 Pitch adjustment emere bue ci recede ues 28 5 5 C70 Configure Nexus ns eie oe eere eoe Ee 28 5 5 1 O71 Wind master iia eget t beg eode VARA 29 5 5 2072 Eog master ee db do tr bu dede ed dee all dedi 29 5 5 3 C73 Function on terminal INS sarissa nenii s iaag 29 5 5 4 Connection of trim 29 5 5 5 O74 Demor miode 3 n e oed tdg ect eig beg 30 6 Maintenance and fault 1 31 6 1 31 6 2 Fault e D 31 62 1 GEN CMT 31 6 2 2 Fault actioni uade eve dor bodie aede det ru ES VANAN 32 6 2 3 Error messages iota He cH Dee pride obe hati eid buen e tinea add 32 Visier ET 33 FA Technical specifications nierien erede ese lee eo RR v eie lue Dade 33 7 2 Nexus data bus introduction and user 33 8 Optional Accessories minita VANA Eder tis lues edd ed 35 9 Abbreviations EL 37 10 Warranty iioi tacet er aret ede ed
4. 30 6 2 30 6 2 1 Fels kning generellt ssssssssssssssssssssssssssrssssnnsnnnnnsnnn nn nn nn nr NAR Rn nn nn nn 31 6 2 2 Fel Ata 32 T SpecifikatioOner ecce aeaaea ere dedecesecedecetedsdedevacedecedersteeetetens 32 7 1 Tekniska specifikationer 32 7 2 NEXUS NatVark tete 33 8 Andra delar i Nexus 35 9 Forkortningar ee erede 36 43 INNEH LL I F RPACKNINGEN Svenska 1 Inneh ll i f rpackningen Nexus Wind Data levereras tillsammans med alla monteringsdetaljer Kontrollera varje del f re installationen ANTAL DETALJ NUMMER Instrument Nexus Wind Data Instrumentskydd Borrmall Bruksanvisning Garantisedel Aterf rs ljarlista Spanningskabel r d och svart 3 m Extra ndhylsor 0 25 mm Extra andhylsor 0 75 mm Monteringsskruvar f r instrument Runda gummiproppar f r att t cka Monteringsskruvarna F rpackning siliconfett Anslutningsk pa MEUM 2 4 poliga skruvterminaler Qi ABROOH aaa aaa a Endast i f rpackning med Wind data instrument komplett med Vindgivare Nexus 25m mastkabel F stskruvar f r vindgivare Vindgivar
5. 10 3 2 Ominitialisering av ett 12 A UKTI ONC thesi ee 12 43 Om denna Manali avn torte tret mte 12 4 2 S anv nds de fyra 12 4 2 FUNKTION G tete cete retra etri 13 42 2 e 13 ieu UM Uk Mc Mr 13 qd 14 4 2 5 Nollst llning av ett v rde 14 4 12 6 ecce Porte cett co tme ote A ee 15 4 27 BelysSninigr eee eee eee ee RAA RR 15 4 3 H vudfu nktiOner otio eene BA 15 4 4 15 4 5 Underfunktioner ette ec A es 15 4 5 1 Relativ vindhastighet 16 4 5 2 Sann vindhastighet 000022 16 4 5 3 Maximal sann vindhastighet 16 4 5 4 B tfart mot eller med vinden 16 4 5 5 Batterisp nning BAT 16 4 5 6 Batiart BSP e ee te ted 18 4 5 7 Triplog 19 4 5 8 Vattentemperatur TMP 19 4 5 9 Trimfunktion f r kryssvinkel eller fart 19 4 6 Funktioner med Wind Data i Nexus 20 4 6 1 Geografisk vindriktning 21 4 6 2 WCV Fart mot e
6. 5 5 3 Anslutning av extern tryckknapp F r att b de s tta styrreferens STEER Pilot och farttrim SPEED Trim r det optimalt att ansluta en TRIM knapp f r farttrim till Wind Data instrumentet och en TRIM knapp till Nexus Server som s tter kompass minne eller vindvinkelreferens En s dan installation medger att b de farttrim och kurstrim kan utf ras med tv separata TRIM knappar 69 Svenska 5 INST LLNINGAR Inkoppling av tryckknapp Koppla in en slutande tryckknapp mellan terminal 3 och jord Det r m jligt att koppla flera tryckknappar parallellt t ex en p styrbords sida och en babord Tryckknappens artikel nummer 19763 5 5 4 Demo mode C74 Inst llning av demo mode demonstrations l ge sker genom att s tta DEM till On Instrumentet visar d refter exempel p data utan att givare anslutits I intervaller om ca 7s kommer text DEM att visas f r att f rhindra f rv xling med verkligt data om demo valts av misstag 70 6 UNDERH LL Svenska 6 Underh ll och fels kning 6 1 Underh ll e Reng r endast instrumenten med mild tv ll sning Anv nd ej h gtryckstv tt e F rvaring under en l ngre tid i str ng kyla rekommenderas ej e Ta bort vindgivaren fr n en liggande mast som f rvaras ver vintern e Applicera silikonfett p samtliga kontakter redan vid h stupptagningen e Anv nd alltid instrumentskyddet d instrumentet ej anv nds e Kontrollera anslut
7. NEXUS WIND 24 Installation and Operation Manual INTRODUCTION Introduction Thank you for choosing Nexus Wind Data instrument We are convinced that you will appreciate all the valuable information either you are a cruiser or a racer It is important that you are following this instruction regarding installation and operation If the instrument are to be used in a Nexus Network there are some systems settings that are dependent on where the transducers are installed i e at the instrument or at the Server EN This manual is written for Nexus Wind Data instrument version 1 00 Edition June 2000 CONTENTS 1 Part specificatloriS x itidem equi edat E 4 2 Installation 56 5 ei ed odere tt ere f a 6 2 1 Installing the instrument 7 PAN ET y 8 2 3 Connections in Nexus Network 8 2 4 Connection of log 9 3 First start only in a Nexus 10 3 1 Initialising the 10 3 2 Re initialising the instrument 10 L Operati N siha EE 11 4 1 Aboutthis manual tie e eene teca iue 11 4 2 How to use the 4 push buttons 12 42 1 enenatis tte tet elits 12 42 2 DOWN iei teet
8. Kilometer timmen Knop Flytande kristall f nster L g Meter Magnetisk Maximal Engelsk mil i timmen Medel Blandad Navigation N sta terg till tidigare funktion Sj Hur grov f r d mpning Fart ver grund Fast Temperatur Trim Trippm tare Sann Sann vind riktning Enhet Anv ndare Variation missvisning Nyttohastighet Hastighet mot WP Vindvinkel Felet vinkelr tt mot v gen Minus Plus 76 10 GARANTI Sve GARANTI ALLM NT Alla produkter r utvecklade och tillverkade f r att motsvara den yppersta bransch standarden N r produkten r korrekt installerad handhavd och underh llen i enlighet med beskrivningen i produktens manual kommer den att bidra med m nga rs tillf rlitlig drift Ut ver produktens tekniska manual kan ocks v r v rldsomsp nnande terf rs ljar och serviceorganisation bist med ytterligare information och assistans GARANTIOMFATTNING Garantin t cker reparation av defekta delar som beror av fel h nf rda till tillverkningen av produkten Garantin t cker reservdel samt arbetstid om produkten l mnas in och repareras i det land d r produkten ink ptes Garantiperioden framg r av manualen och b rjar l pa fr n den dag produkten ink ptes Ovanst ende garanti r tillverkarens enda garanti vilket inneb r att ytterligare villkor ej r till mpliga p produkten GARANTIVILLKOR Produktens ink pskvitto med angivet ink psdatum och ifyllt garantikort
9. LLNINGAR Svenska Obs om Du t ex konfigurerar f r anslutning av loggivare i Wind Data instrumentet men skruvar in givaren i Nexus Server kommer varken fart logg eller vattentemperatur att visas n gonstans i Nexus Systemet 5 5 1 Vindmaster C71 Inst llning On inneb r att instrumentet r vindgivarmaster i st llet f r Nexus Servern Inst llning OFF inneb r att Vindgivare skall anslutas till Nexus Server Logg master C72 Inst llning On inneb r att instrumentet r loggivar master i st llet f r Nexus Servern Inst llning OFF inneb r att Loggivare skall anslutas till Nexus Server 5 5 2 Funktionsval p skruvterminal 3 C73 Inst llning och val av funktionstyp p instrumentets skruvterminal nummer 3 F ljande val kan g ras TMP Standardinst llning f r temperaturgivare TRM Anslutning av yttre monterad STEER Pilot TRIM knapp SPT Anslutning av yttre monterad SPEED TRIM knapp MOB Anslutning av yttre monterad Man ver bord M O B knapp Endast i Nexus N tverk Roll Anslutning kr ngningsgivare N r val av funktion Roll g rs kan ytterligare offset justeringar g ras i kalibreringsgrupp C64 under vindinst llningar C50 WND Genom att t ex ansluta loggivaren till Nexus Server blir vattentemperatur tillg nglig p Nexus n tverk V ljs SPT SPeed Trim kommer den yttre trimknappen att aktivera ett TRIM kommando som s nds s nds ut till samtliga SPEED Trim instrument
10. e Cut the Nexus Network cable to length Peel off about 35 mm 1 4 of the cable insulation Remove about 6 mm 1 4 from the 3 isolated wires the 4th wire is an earth screen Attach the 4 cable protectors to the wires using a pair of flat pliers e Connect the 4 cable protectors to the 4 pole jack plug as shown Apply silicon paste on all locations as shown Po I Silicon paste X 1 1 pS Siliconfett Re ae z Siliconfett LA ire Note Must be done to avoid corrosion e Apply silicon paste to the instrument connection pins at the back of the instrument Press the jack plug onto the instrument pins Press down the cable in the cable leads Mount the connection back cover with the screw e Mount the instrument in the pre drilled position Note Use all 4 screws and tighten the screws in cross pattern so the gasket will be evenly compressed to 1 3 of its original thickness Very important for a correct sealing to avoid leakage e Press on the 4 rubber caps to seal and hide the mounting screws Your instrument installation is done 2 INSTALLATION 1 2 Installing cable The power cable is connected via a 3A fuse from the battery or at the boats fuse panel and direct to the instrument or Serv
11. is toggling but they can be locked or unlocked by use of the KEY 21 4 OPERATION 3 6 5 BTW Bearing and angle deviation relative next course To get this function set NAV On C14 See 5 1 4 This function is using both the Compass and the navigator information to calculate the angle deviation between the bearing and the course after tack i e the angle deviation is exactly what you should expect after the tack BTW is showing the actual Bering to Waypoint and NXT is showing the negative positive tack or downWind angle that you would expect if you where tacking or jibing You may use COG but our recommendation is to use the Compass since the response and accuracy is superior If you use COG without a differential GPS you will loose too much accuracy in the information BTW and NXT is toggling TACK Example If you expect your drift to be 05 your tack should be made when you read NXT 05 to be on and stay on lay line While you are approaching the proper angle the value is negative i e 12 and then increasing to 00 which is on lay line after tack except for the drift which is the margin you must add to compensate for the drift Note This function is only used on the last leg 22 4 OPERATION DOWN Wind When sailing downWind the boat can always be sailing at the highest speed towards the mark When NXT is 00 you should jibe because your drift is not im
12. NMEA 0183 input output If you need to be able to read the depth information on more then one instrument the Server is the only choice Network bonus function 18 4 OPERATION If you are using the race timer on the Multi or Log instrument you will have a graphical 60 second countdown timer popping up on this instrument In this example there is 45 second to start 3 6 1 Geographic Wind direction TWD To get this function set NAV On C14 See 5 1 4 Text TWD is displayed shortly then is the abbreviation for Wind directions displayed SSW NO WNW etc together with the numerical direction below The graphic direction is also displayed by pressing MODE one or more times until the display to the right is displayed together with the pointer If the Compass transducer is missing but there is a GPS installed you may use the GPS as a reference for heading under the criteria that the vessel must be moving Change C33 from USE Hdc to USE COG See 5 3 3 When the boat is laying still the TWD will be random readings if COG is used Each sector 5 You may also check 2 a marker at present Wind direction asa remainder The marker will stay until power off or by clearing the function MET A Wind shift of 5 will be easy to detect after hours of sailing Select function TWD 360 with MODE and when the text TWD is flashing press KEY The marker is now set When there is a constan
13. Serial number A B C Date of purchase Date installed Dealers stamp Tick here if you do not wish to receive news about future products 39 Svenska INTRODUKTION Inledning Tack f r att du valt Nexus Wind Data instrument Vi vertygade om att Du kommer att uppskatta all v rdefull information som r tillg nglig p detta instrument vare sig Du r en kappseglare eller n jer dig med familjesegling och f r att Du skall f st rsta m jliga nytta av ditt nya vindinstrument r det d rf r viktigt att du noggrant f ljer installationsanvisningen Skall vindinstrumentet anv ndas i ett Nexus n tverk m ste vissa systeminst llningar g ras beroende p var Du installerar log och vindgivare Du kan ven g ra flera val vid anv ndning av tillbeh r som exempelvis yttre TRIM knapp Se mer i kapitel Inst llningar Denna manual r skriven f r Nexus Wind Data instrument version 1 00 40 Utg va Oktober 1997 41 INNEH LL Svenska 141 eee e e 4 SMS TAN P nU toot eee on 6 2 1 Installation 5 7 2 2 Kabe ldragnirg E a 8 2 3 Inkoppling i ett Nexus 8 2 4 Installation av 00 9 3 F rsta start endast i Nexus n tverk 10 3 1 Initialisering av instrumentet
14. att hamna rhumbline efter slag Efter ett slag eller tar det n gon minut innan v rdet NXT har stabiliserats Funktionerna och NXT v xlar men kan l sas l sas upp med NYCKEL 61 Svenska 4 FUNKTIONER 4 6 5 BTW NXT B ring och vinkelavvikelse mot m rke Funktionen kr ver kompass och navigator samt tillval NAV i inst llningar C14 se 5 1 4 BTW visar b ring till m rke NXT visar negativ eller positiv sl r kryssvinkelskillnad efter gipp slag baserat kompasskurs eller COG dvs verklig kurs ver grund inklusive avdrift Vi rekommenderar att anv nda kompass Anv nds COG utan differentiell GPS mottagare kommer kurs ver grund att variera f r mycket f r att upplevas stabilt BTW och NXT visas v xelvis KRYSS Exempel Om Du uppskattar din avdrift till 05 skall Du sla nar NXT visar 05 f r att hamna layline och d rmed g rakt p m rke F rst visas NXT negativt t ex 14 f r att sakta minska 00 och d refter kas b ring positivt vilket r Din marginal d r Du m ste inkludera uppskattad avdrift och of rutsedda vindskift 62 4 FUNKTIONER Svenska SLOR Vid sl r kan b ten alltid seglas med h gsta fart mot m rke VMG eftersom motsvarande sl rbog efter gipp dvs n r NXT visar 00 kommer att ske s att samma optimala sk rningsvinkel kan h llas nda till m rke utan st rre kurskorrigeringar Funktionerna BT
15. fede dete ed vedo ede Steves 12 42 3 UP iib EI p RERO dite cv 12 4 24 KEY au a se ies 12 4 2 5 Olea eb uet EIE RA lutte i etatis tet 13 4 2 6 Calibration zs eo door te beat of pestem decer t edes 13 4 2 7 bighting emet aee uet tie qon daten fae ed 13 43 Main TUMCUO Rs crt 14 4 4 Analogue function 14 4 5 SUDANEN S ea a tere teo ede cette SS ni SE CANE 15 4 5 1 Apparent Wind Speed AWS 15 4 5 2 True Wind Speed TWS 15 4 5 3 True maximum Wind 15 4 5 4 Velocity Made Good 15 4 5 5 Battery voltage BAT 16 4 5 6 Boat speed BSP 16 4 5 7 Trip log TRP Option eit eiu te eis 16 4 5 8 Water temperature TMP 16 4 5 9 Trim function for optimum Wind angle or speed 16 4 6 More Wind Data functions Nexus 18 4 6 1 Geographic Wind direction 19 4 6 2 Waypoint Closing 19 4 6 3 Xt r ck error XT ES iini Re hne Miss 19 4 6 4 HDC NXT Course after tack or jibe 21 4 6 5 BTW NXT Bearing and angle deviation relative next
16. for more information Art No Nexus Complete Sets 20445 3 Multi Control instrument with Server 20445 1 Speed log complete with transducer 20445 2 Depth complete with transducer 21033 1 GPS Navigator complete with instrument and antenna 21440 Wind Data instrument complete with transducer Nexus Digital Repeaters 20445 4 Multi Control 21032 GPS Navigator Nexus NMEA 20445 5 Autopilot instrument 21210 Remote Control Nexus remote and instrument 21434 1 Wind Data repeater Nexus Analogue Repeaters 20550 1 Wind 20550 2 Steer Pilot 20550 6 Compass 20550 3 Log 0 16 KTS 20550 4 Log 0 50 KTS 20550 5 Depth 0 200 m 20550 7 Depth 0 600 FT 20550 8 Speed Trim 20550 9 Rudder Angle indicator Nexus Transducers 20700 Log Temp 0 30 KTS retractable 8 m 26 ft cable 20711 2 Depth 0 8 150 m 2 6 490 ft retractable 3 8 m 10 26 ft cable 20721 Masttop Unit 22 m 72 ft cable 20860 Fluxgate Compass 8 m 26 ft cable 21000 GPS Antenna Nexus NMEA fix 10 m 33 ft cable 21117 GPS Compass XL1000 portable 21170 GPS Navigator XL300 portable 35 8 OPTIONAL ACCESSORIES 21035 21134 21134 21036 19841 19941 19923 69999 21248 19763 21154 19038 19216 18129 18500 18501 20966 67400 15 21453 Nexus inboard hydraulic Autopilot Servo unit Pump set hydraulic steering Pump set complete with cylinder and solenoid Rudder angle transmitter Other Nexus Accessories Maxi repeater via NMEA yellow digit
17. m jligt fran den s krade elpanelen Den tremeters sp nnings kabel som ing r komplett med andhylsor och d rmed f rdig att kopplas in OBS S tt C71 i On se 5 5 1 Anslut alltid Gr ns kring atteri och instrument Sk rm Vit Svart 2 3 Inkoppling i ett Nexus n tverk Om du redan har ett Nexus n tverk dvs en Server r det mer praktiskt att installera givaren till Servern Instrumentet ansluts sedan var som 3A S kring SCREEN 12 GREEN 13 YELLOW 14 WHITE 15 SCREEN 16 Instrumentet ansluts till Servern skruvplint skruv 5 6 7 och 8 eller till n rmaste instrument 48 Sk rm Svart R d 1 Nexus Star D 20 220 eller 2200 2 4 Installation av loggivare 3A S kring uu nar ett annat logginstrument en Star logg 2200 220 Power eller Direction kan du ansluta endast en kabel fr n det instrumentet till skruv 4 p Wind Data instrumentet Om Du inte har n got annat instrument kan en loggivare anslutas direkt till instrumentet F r att underl tta inkopplingen finns en kopplingsbox Art nr 21453 tillbeh r Fr n Server eller annat Nexus instrument 49 Sve 50 INSTALLATION GREEN V YEU Z y CHA INSTRUMENT Loc TRANSDUCER LABEL 1 3 F RSTA START Svenska 3 F rsta start endast i Nexus n tverk 31 Initialisering av instrumentet Vid uppstart av instrumentet utf rs en sj lvtest Displayen visar f rs
18. m ste medf lja f r at validera garantikrav som sker enligt procedur beskriven nedan Produktens garanti r inte m jlig att verf ra utan g ller endast f r den ursprungliga k paren Produktens garantin g ller inte i de fall serienummer saknas felaktig installation skett felaktig els kringsf rfarande omst ndighet f rorsakad av felaktigt handhavande externa orsaker s som modifieringar eller service utf rd av annan n tillverkaren eller av denne auktoriserad distribut r eller genom anv ndning utanf r de tekniska gr nsv rden som specificerats i produktens manual Tillverkaren tillverkarens distribut rer och terf rs ljare r inte ansvarig och kommer inte ati kompensera direkta eller indirekta skador som uppkommit p g a felaktigheter i produkten Tillverkaren r inte heller ansvarig f r person skador eller skador p tredje man som uppkommit p g a anv ndning av produkten Tillverkaren tillverkarens distribut rer och terf rs ljare r inte ansvariga f r kostnader i samband med sj tester fels kningar i b tar etc oavsett om produkten r under garanti eller inte Tillverkaren tillverkarens distribut rer och terf rs ljare bist r g rna med denna service Nedlagda kostnader kommer i dessa fall att debiteras k paren i enlighet med g llande priser Tillverkaren tillverkarens distribut rer och terf rs ljare reserverar sig r tten att i de fall reparation ej r m jlig att genomf ra inom en rimlig tidsperi
19. med vinden Vissa funktioner som beskrivs h r kr ver anslutning till Nexus n tverk Som f rsta exemplet ska vi anv nda TRM AWA Apparent Wind Angle som inneb r val och inst llning av nskad kryssvinkel Vindvinkelavvikelse v lj text TRM OFF Tryck samtidigt p UPP och NER s att displayen blinkar V lj AWA med NER och avsluta med NYCKEL V lj d mpning d0 d9 hur snabb visningen skall vara d0 min d9 max med UPP eller NER och avsluta med NYCKEL Senast inst lld vindvinkel visas se ven C64 5 4 7 ven inmatning av nskad vindvinkel r m jlig Acceptera visad vindvinkel med NYCKEL eller mata in ny nskad 57 Svenska 4 FUNKTIONER vindvinkel med UPP NER och FUNKTION innan Du trycker p NYCKEL Inmatad vindvinkel lagras i flyktigt minne och r endast tempor r Se ven inst llningar av REF i C64 d r vald vindvinkel AWA ligger kvar i minnet och visas automatiskt varje g ng Du v ljer AWA Trim P displayen visas nu texten TRM och AWA v xlande tillsammans med inst lld vindvinkel P den grafiska displayen visas referensen samtidigt med Dii ech sann motsatt sida dvs inst lld vinkel visas upp till TSfarsekti metam 15 bch 30 visas hela sektorn Avvik sl cka de fyllda sektorerna Sektorerna fylls ter n r vindvinkeln ter r inom avvikelseomr det TRA Trimma p fart g till funktion med text Tryck samt
20. nder racetimern p Multi eller Log instrumentet kommer Wind Data automatiskt att visa en grafiskt nedr knings timer fr n 60s till start P bilden till h ger r det 45 sekunder kvar till start 59 Svenska 4 FUNKTIONER 4 6 1 Geografisk vindriktning TWD Tillvalsfunktion NAV z On i inst llningar C10 Text TWD visas kortvarigt d refter visas t ex SSW NO WNW etc tillsammans med numerisk vindriktning i grader Grafisk visning av TWD blir ocksa tillganglig Tryck pa FUNKTION tills dess att TWD 360 visas tillsammans med geografisk vindriktnings pil Saknas kompassgivare kan en GPS navigator delvis ers tta kompassinformationen med COG kurs ver grund under f ruts ttning att b ten g r fart genom vattnet En stillaliggande GPS kommer att orsaka slumpm ssig visning av TWD ndra inst llning C33 fran USE till USE COG se 5 3 3 Kontroll av geografisk vindvridning kan g ras genom att s tta en mark r vid aktuell vindriktning Mark ren ligger kvar tills dess att Du s tter en ny bryter sp nningen eller kopplar ur funktionen En vindvridning 5 blir d rf r l tt att uppt cka ven efter flera timmars segling V lj funktion TWD 360 med FUNKTION och n r texten TWD blinkar blinkar trycker Du NYCKEL Du har nu satt mark ren vid aktuell geografisk vindriktning Vid en best ende vindvridning blir mark ren kvar blinkande och verklig riktning visas med f
21. these functions see C12 5 1 2 3 4 Analogue function Change Wind scale between 180 and 60 with MODE Selected scale is shown with the LCD arrow pointing at scale The text APP displays selected main function as apparent Wind angle or Wind speed MIX 180 The text MIX 180 means that both APP and TRUE Wind angle is displayed in scale 180 MIX 60 The text MIX 60 means that both APP and TRUE is displayed in scale 60 The scale can be altered between 60 and 180 to get more accurate readings At scale 180 each sector represent 5 and at scale 60 each sector represent 1 See the example below VIND True wind angle Apparent wind angle AWA 5 True wind T WIND TWA n wind angle 30 14 4 OPERATION 3 5 Sub functions Select sub function with UP or DOWN Information text for the sub function is displayed You may also park your favourite function so it will automatically be displayed after power on Press both MODE and KEY to park the displayed function The display will flash once to confirm that you have parked the function 3 5 1 Apparent Wind Speed AWS The text AWS Apparent Wind Speed and its value is displayed below The text AWS is toggled with the text KTS KnoTS M S Metres S or BF Beaufort 3 5 2 True Wind Speed TWS The text TWS True Wind Speed and its value is displayed below The text T
22. vad som skall visas de siffrorna Det finns fem olika val AWA Relativ vindvinkel Loggivare kr vs ej TWA Sann vindvinkel relativt b ten Loggivare kr vs AWS Relativ vindhastighet Loggivare kr vs ej TWS Sann vindhastighet relativt b ten Loggivare kr vs WIA G ller endast f r Nexus n tverksanslutning Detta systemval inneb r att en automatiskt systeminst llning utf rs lika C51 i Nexus Multi Control instrument 64 5 INST LLNINGAR 5 1 3 Tillval av batfart logg samt vattentemperatur C13 Inst llning OFF tar bort visning av b tfart triplog samt vattentemperatur f r dig som f redrar att anv nda en separat fartlog Wind Data instrumentet kan anv ndas som Server i Nexus n tverk genom att log och vindgivare ansluts till instrumentet som i sin tur s nder information om b tfart distans och vattentemperatur till ett eller flera Multi Control instrument Man beh ver allts inte se b tfart och vattentemperatur ven om Wind Data instrumentet ber knar och s nder ut informationen se C7 5 5 2 5 1 4 Tillval av NAV funktioner C14 NAV funktioner r endast anv ndbart med Wind Data i ett Nexus n tverk med kompassgivare och navigator Inst llning NAV On adderar funktionerna som visas under Nexus n tverk Se 4 6 5 1 5 Ljudsignal vid knapptryckning C15 OFF eller On Inst llning On inneb r att instrumentet piper vid varje knapptryckning Inst llning OFF inneb r tyst funkt
23. vindvinkel 90 grader tv rs b ten och VMG z b tfart Du med motor rakt mot eller med vinden Se figur 56 4 FUNKTIONER Svenska 4 5 5 Batterisp nning BAT tillval Texten BAT visas och batterispanning i volt Sp nningen m ts i instrumentet och tar inte h nsyn till ev sp nningsfall i kablar fr n batteriet 4 5 6 B tfart BSP tillval Texten BSP och b tfart vattenhastighet visas Text BSP visas v xelvis med vald enhet KTS KMH eller MPH N r loggivare ansluts till Wind Data instrumentet f r Du tillg ng till sann vindhastighet och vindvinkel VMG B tfart Trip samt vattentemperatur 4 5 7 TRP tillval Texten TRP och avverkad tripdistans visas fr n 0 00 till 99 9 sj mil kilometer eller miles d refter fr n 0 00 igen Nollst ll trippdistans genom att samtidigt trycka p UPP och NER 4 5 8 Vattentemperatur TMP tillval Texten TMP och vattentemperatur visas i Celsius eller Farenheit Du kan v lja bort visning av batfart BSP triplog TRP samt vattentemperatur TMP Se inst llningar 4 5 9 Trimfunktion f r kryssvinkel eller fart tillval Text TRM och OFF visas n r funktionen inte aktiverats Trim funktionen kan anv ndas som ett hj lpmedel att h lla nskad kryssvinkel eller till att uppt cka fartf r ndringar efter trim av segel och rigg Trimfunktionen kan t ex visa avvikelse fr n b tfart eller VMG b tfart rakt mot eller
24. 21210 Remote Control Nexus fj rrkontroll och instrument 21434 1 Wind Data Nexus Analoga Repeaters 20550 1 Wind 20550 2 Steer Pilot 20550 6 Kompass 20550 3 Logg 0 16 KTS 20550 4 Logg 0 50 KTS 20550 5 Djup 0 200 m 20550 7 Djup 0 600 FT 20550 8 Farttrim 20550 9 Roder vinkel indikator Nexus Givare 20700 Logg Temp 0 30 KTS l stagbar 8 m 26 ft kabel 20711 2 Djup 0 8 150 m 2 6 490 ft l stagbar 3 8 m 10 26 ft kabel 20721 Masttopsenhet 22 m 72 ft kabel 20860 Fluxgate Kompass 8 m 26 ft kabel 21000 GPS Antenn Nexus NMEA fast 10 m 33 ft kabel 21117 GPS Compass XL1000 handburen 21170 GPS Navigator XL 300 handburen 74 8 TILLBEH R I Nexus SERIEN Svenska 21035 21134 21134 21036 19841 19941 19923 69999 21248 19763 21154 19038 19216 18129 18500 18501 20966 67400 15 21453 Nexus hydrauliska Autopilot Servoenhet Pump set f r hydraulisk styrning Pump set komplett med cylinder och solenoid Rodervinkelgivare Andra Nexus tillbeh r Maxi repeater via NMEA gula siffror Maxi repeater via NMEA r da siffror Mastf ste f r en Maxi repeater Mastf ste f r tv Maxi repeaters Nexus PC interface FD med 1 m 3 3 ft kabel Inneh ller en 3 2 Med mjukvara f r waypoint editeringing och data bus hantering samt NMEA interface Extern tryckknapp f r Taktik och MOB funktion H gfarts Paddelhjul upp till 40 KTS Monteringssats f r inv ndigt montage av lodgivare Bron
25. 4 KEY E A press on KEY unlocks a digit to access edit mode When unlocked the digits are active flashes and can be edited by pressing DOWN UP and MODE as required When finished editing lock the digit by another press on KEY 12 4 OPERATION 3 2 5 Clear A press on DOWN and UP together clear digits 3 2 6 Calibration To access calibration mode press and hold KEY more than 2 seconds To return to main function mode press KEY when the text return RET is shown 3 2 7 Lighting The instrument uses red back lighting for the display and the 4 push buttons The lighting can be set at 4 different levels To access the light control press and hold MODE for more than 2 seconds The flashing text Lit OFF will be displayed and the display will be lit momentarily To select between the 4 light levels press UP LOW MID MAX and OFF To lock the selected level press KEY The selected light level will be copied to all Nexus instruments connected to the system When the lighting is on it is not possible to reduce or turn off the lighting on an individual instrument 13 4 OPERATION 3 3 Main function Top data is relative Wind angle AWA Apparent Wind Angle As an alternative to AWA the following can be displayed AWS Apparent Wind Speed TWA True Wind Angle if the log transducer is connected TWS True Wind Speed if the log transducer is connected To change between
26. 90 135 180 225 270 000 045 090 135 180 225 270 St ll in v rden efter det medf ljande kalibreringssertifikatet f r var 45 e grad 67 Svenska 5 INST LLNINGAR C62 315 315 5 4 6 Hastighets referens vatten log eller GPS C63 Endast f r Nexus n tverk Inst llning BSP inneb r normal anv ndning av loggivare fart genom vattnet f r att ber kna sann vind hastighet och riktning VMG samt NXT funktionen tillsammans med BTW Inst llning SOG inneb r att fartinformation tas fr n GPS i st llet T nk p att med GPS som fartgivare kr vs att b ten g r viss fart f r att ge tillfredsst llande v rden Anv nds differentiell GPS kas noggrannheten betydligt 5 47 Inst llning av trimreferensC64 N r skenbar vindvinkel AWA v ljs som trimreferens efter sp nningtillslag kommer v rdet inst llt i C64 att f resl s 5 4 8 Inst llning kr ngnings offset C68 Denna inst llning r endast tillg nglig om Roll r valt i C73 du m ste l mna kalibreringsl ge och g in igen Inst llning av kr ngningsoffset Montera f rst givaren enligt instruktion justera d refter offset s att Roll visar 00 n r b ten ligger lodr tt dvs krangning r 00 Genom att ange framf r v rdet kommer visad och uppm tt kr ngning att minskas med motsvarande v rde N r offset anges utan tecken kommer v rdet att adderas till uppm tt kr ngning N r givare anslutits komm
27. Inst llning kalibrering av vind 50 2 47 0 3331 26 5 4 1 Nexus Inst llning av sann eller relativ vindvinkel C51 26 5 4 2 Val av enhet f r vindhastighet 52 1111111 26 5 4 3 Vindhastighets kalibrering C53 eese 26 5 4 4 Justering av visad vindvinkel C54 esssss 26 5 4 5 Kalibreringstabell f r vindgivaren C55 C62 26 5 4 6 Hastighets referens vatten log eller GPS C63 26 5 4 7 Inst llning av trimreferensC64 cerent 27 5 4 8 Inst llning av kr ngnings offset 68 27 5 4 9 Inst llning av langskeppslutning offset C69 27 5 5 Konfigurera Nexus 27 5 5 1 Vindm ster C71 5 ce ede ected 27 5 5 2 Logg maslter G72 reee 28 5 5 3 Funktionsval skruvterminal 3 73 1 2 28 5 5 4 Anslutning av extern 29 5 5 5 Demo mode 74 30 6 Underh ll och fels kning 1e 30 6 1 0
28. MITED WARRANTY The warranty covers repair of defective parts due to faulty Manufacturing and includes labour when repaired in the country of purchase The warranty period is stated in the product manual and commences from the date of purchase The above warranty is the Manufacturer s only warranty and no other terms expressed or implied will apply The Manufacturer specifically excludes the implied warranty of merchantability and fitness for a particular purpose CONDITIONS The supplied warranty card and receipt with proof of purchase date must be shown to validate any warranty claim Claims are to be made in accordance with the claims procedure outlined below The warranty is non transferrable and extends only to the original purchaser The warranty does not apply to Products from which serial numbers have been removed faulty installation or incorrect fusing to conditions resulting from improper use external causes including service or modifications not performed by the Manufacturer or by its national distributors or operation outside the environmental parameters specified for the Product The Manufacturer will not compensate for consequential damage caused directly or indirectly by the malfunction of its equipment The Manufacturer is not liable for any personal damage caused as a consequence of using its equipment The Manufacturer its national distributors or dealers are not liable for charges arising from sea trials installation surveys O
29. PP stegar du upp t i underfunktionslistan I redigeringsl ge kar du ett v rde 424 NYCKEL NYCKEL anv nds f r att l sa l sa upp en funktion f r att kunna ndra den N r en funktion r i redigeringsl ge blinkar texten siffran Den g r d att ndra med UPP eller NER l s d refter med NYCKEL igen 888 u 53 Svenska 4 FUNKTIONER 4 2 5 Nollst llning av ett v rde amp att trycka UPP och NER samtidigt nollst lls ett v rde 4 2 0 Kalibrering F r att komma in i kalibreringslage h ll NYCKEL nertryckt i tv sekunder F r att komma ur kalibreringsl ge tryck NYCKEL n r texten 7 0 RET visas 4 2 7 Belysning Instrumentet har en orange bakgrundsbelysning f r display och gt tryckknappar Belysningen valbar i tre steg Tryck FUNKTION under minst 2 sekunder s att texten Lit visas V lj belysningsniv er l g LOW medel MID h g MAX och sl ckt OFF med UPP eller NER avsluta med NYCKEL Vald belysningsniva kommer att s ttas p alla instrument som kopplade till n tverket Om du har en Server ansluten kan du koppla in en str mbrytare till den f r att sl p och av ljuset f r installation se Serverns bruksanvisning 54 4 FUNKTIONER Svenska 4 3 Huvudfunktioner verst visas relativ vindvinkel AWA Apparent Wind Angle Alternativt kan f ljande information visas Relativ vindhastighet AWS Apparent Wind Speed San
30. VMG Velocity Made Good Log transducer TBS Optimum speed based on polar diagram PC NMEA 0183 through Nexus Server OFF Function is OFF When BSP or other function is selected the dampening d3 is flashing Select dampening level and confirm with KEY The text OFF is then displayed to show that the function is selected but no reference is yet set Press KEY to set BSP reference Press the KEY every time you wish to set a new trim reference value There is an option to use an external trim button to set a new trim reference See more in the calibration 3 6 More Wind Data functions Nexus Network By adding or using the Wind Data instrument in the Nexus Network more functions will be added if the corresponding transducer is connected The Wind Data functions may be added or removed by the user The Wind Data instrument can be used in a small Network together with the Multi Log or analogue instrument without a Server In order to make the installation easy when using both log and Wind transducer in a small Network we recommend you to install with connection kit art no 21453 Only one cable will carry the signals to the instrument then there is one Network power cable to the Multi or Log instrument See 2 1 4 When using the Wind Data in a bigger Network with more then 3 transducers we recommend you to use the Nexus Server Only one cable will be used to connect all instruments You will also have the
31. W och NXT v xlar men kan l sas l sas upp med NYCKEL OBS Denna funktion anv nds endast p sista benet 63 Svenska 5 INST LLNINGAR 5 Inst llningar kalibrering F r att komma in i Inst llningar skall Du h lla NYCKEL nedtryckt i minst 2 sekunder Du terg r till normaldrift genom att trycka NYCKEL n r texten rEt visas V lj nskad huvudkalibreringsgrupp C10 C70 genom att trycka p FUNKTION C10 C15 USR Anv ndarinst llningar C20 C24 BSP Logg givar och temperatur kalibrering C30 C33 HDC Kompass inst llning deviation C50 C64 WND Vindgivarinst llning kalibrering C70 C74 CON Konfigurering av Nexus systemet D refter v ljs respektive inst llning kalibrering inom huvudkalibreringsgruppen med NER och UPP F r att ndra tryck NYCKEL Mark ren blinkar p den siffra som kan ndras anv nd minus NER f r att minska v rdet och plus UPP f r att ka samt mark r FUNKTION f r att flytta till n sta siffra N r Du r klar trycker Du ter NYCKEL motsvarar datorns ENTER knapp 5 1 Anv ndarinst llning C10 F r att terg till normaldrift tryck NYCKEL n r rEt visas 511 Inst llning av d mpning C11 D mpning av vindvinkel vindhastighet b tfart VMG mm v lj mellan dO 0s och d9 1 20 F r att ndra dampningen tryck p NYCKEL och ndra med NER eller UPP och lagra med NYCKEL 51 2 Val av huvudinformation C12 Inst llning av
32. WS True Wind Speed is toggled with the text KTS KnoTS M S Metres s or BF BeauFort 3 5 3 True maximum Wind speed Press the KEY in the sub function TWS to display maximum true Wind speed After 5 seconds the display will go back to TWS again Re set or clear the MAX Wind speed value by pressing UP and DOWN together or switch off the power WIND 3 5 4 Velocity Made Good VMG VIND The text VMG Velocity Made Good is displayed with the actual boat speed towards or against the Wind The water speed information from the log transducer is needed The speed information can be taken from the log transducer or from Nexus Network VMG 0 0 knots when the true 2 Wind angle is perpendicular to the boat s 15 4 OPERATION 3 5 5 Battery voltage BAT option The text BAT will display battery voltage The voltage is measured inside the instrument and will not compensate for any voltage drop caused by installation 3 5 6 Boat speed BSP option The text BSP will display boat speed water speed The text BSP will toggle with selected unit i e KTS KMH or MPH As an option you may add or remove displaying boat speed BSP trip log TRP and water temperature TMP See further under calibration 3 5 7 log option The text TRP is displayed and will show trip distance from 0 00 to 99 9 nautical miles kilometre or miles After 99 9 0 00 is displayed Clear trip by
33. ast sektetr Varje sektor motsvarar 5 4 6 2 WCV Fart mot etappm l m rke Texten WCV visas tillsammans med fart rakt mot det aktiva etappm let eller m rket Kr ver navigator samt tillval NAV On i inst llningar C14 se 5 1 4 4 6 3 Avvikelse fr n kurslinje XTE Texten XTE visas f rst d refter visas en symbolisk b t triangeln p sidan om v gen tre streck tillsammans med avst ndet till kurslinjen Kr ver navigator samt tillval NAV on i inst llningar C14 se 5 1 4 Din b t finns till h ger eller v nster om kurslinjen dvs utefter den ursprungliga b ringen d etappm let valdes Avst nd till mittlinjen visas normalt i sj mil men kan ven visas i Miles eller Km N r avst ndet till mittlinjen r lika med noll f rsvinner triangel symbolen dvs b ten ligger mitt p v gen 60 4 FUNKTIONER Svenska 4 6 4 HDC NXT Kurs och kurs att halla efter slag Funktionen kr ver att kompass anslutits till Nexus Server eller Kompass instrument Tillval NAV on i inst llningar C14 se 5 1 4 Saknas kompass kan kompasskurs ers ttas av COG kurs ver grund genom att v lja GPS referens i inst llningar C33 se 5 3 3 Texten HDC visas tillsammans med aktuell magnetisk eller sann kurs Efter ca 4s v xlas Text ver till NXT som visar magnetisk eller sann kurs att h lla efter slag Obs eventuell avdrift m ste alltid inkluderas i beslutet n r det r dags att 5 f r
34. blar upp till 1200 m Data s nds synkront med en startbit 8 databitar 1 paritetsbit samt 2 stoppbitar med en verf ringshastighet av 9600 baud Detta ger m jligheter till mycket snabb datauppdatering Viss information skickas upp till 10 ggr Per sekund Anv ndare av N tverket Nexus N tverket r ppet f r nya anv ndare och applikationer utan licenser eller avgifter Emellertid r N tverket tillverkarens egendom D rf r m ste specifikationerna f ljas f r att skydda tillverkarens taganden vad betr ffar prestanda och drifts kerhet F r de flesta applikationer r PC interface art nr 21248 ett mycket bra hj lpmedel f r att titta p och logga all data som skickas p N tverket Det g r ven att l gga in Waypoints och rutter via PC n PC interfacet r utrustat med en anslutning till Nexus N tverk samt en 9 polig D sub kontakt f r anslutning till kommunikationsporten RS 232 73 Svenska 8 TILLBEH R I NEXUS SERIEN 8 delar i Nexus serien Nedan finner du en f rteckning ver andra instrument och givare i Nexus serien Art Nr Nexus Kompletta Set 20445 3 Multi Control instrument med Server 20445 1 Speed log komplett med givare 20445 2 Ekolod komplett med givare 21033 1 GPS Navigator komplett med instrument och antenn 21440 Wind Data instrument complete with transducer Nexus Digitala Repeaters 20445 4 Multi Control 21032 GPS Navigator Nexus NMEA 20445 5 Autopilot instrument
35. course 22 2615 e T TE MEET 24 54 C10 User setlifigs unte E ta e Het 24 5 1 1 C11 Select the 24 5 1 2 C12 Select main information 24 5 1 3 C13 Displaying boat speed trip log and temperature 25 5 1 4 C14 Display NAV functions 25 5 1 5 C15 Beep when key is 5 25 5 2 C20 Calibration of 1009 25 5 2 1 C21 Select unit for speed 25 5 2 2 C22 Calibration of log transducer 25 5 2 3 C23 Unit for 26 5 2 4 C24 Temperature 26 5 3 C30 Compass Settings tdt op ec vare vu ce need de Degree aed 26 CONTENTS 5 3 1 C31 True or magnetic course 26 5 3 2 C32 Magnetic deviation 26 5 3 3 Reference for Compass static or GPS 26 5 4 C50 Wind Settings incon d RR E 27 5 4 1 C51 Network setting of true or apparent Wind angle 27 5 4 2 C52 Unit for Wind 27 5 4 3 C53 Wind speed 27 5 4 4 C54 Adjustment of Wind 27 5 4 5 C55 C62 Calibration table for the Wind
36. e instrument a logical ID number on the Nexus Network initialise the instrument press KEY on all installed digital instruments one at the time Note Always wait for the text Init OK N to be displayed before you press KEY on the next instrument The Server automatically gives the first unit ID number 16 then 17 and so on The order in which you press KEY is the same order as the instruments will be given a logical ID number on the Nexus Network The example shows that the instrument version number is 1 00 and the given logical ID number is 16 22 Re initialising the instrument If two instruments by mistake have the same ID number this can cause disturbance and block the information on the Nexus data bus To re initialise the instrument press DOWN and UP together during the power up sequence when version and ID numbers are displayed The display self test is then re started on all instruments and you will be asked to press KEY on each instrument as explained above Note If you do not succeed to re initialise we suggest you disconnect all but one instrument with the same ID number then repeat the above procedure 10 4 OPERATION 3 Operation 3 1 About this manual Each time a push button are referred to in this manual the push button name will appear in bold and CAPITAL letters e g MODE e Unless otherwise stated the push button presses are momentary e Each time a function is mentio
37. e sealant behind the display The instrument gasket eliminates the need for sealant Do not run cables in the bilge where water can appear Do not run cables close to fluorescent light sources engine or radio transmitting equipment to avoid electrical disturbances Do not rush take your time A neat installation is easy to do The following material is needed Wire cutters and strippers Small and large Philips and small flat head screw driver Hole saw for the instrument clearance hole 63 mm 212 2 8 mm drill for the mounting holes in wood 3 2 mm g drill for the mounting holes in fibre glass Plastic cable ties If you are doubtful about the installation obtain the services of an experienced technician The warranty is not valid if you have damaged the instrument by drilling through the front mounting holes 2 INSTALLATION 1 1 Installing the instrument e Place the adhesive drill template on the desired location for the instrument Drill the 4 screw holes using a 2 8 mm drill for wood or 3 2 mm g for fibre glass Use a 63 mm 2 hole saw to machine the clearance hole for the instrument connection socket Remove the template Note Never drill through the instruments 4 mounting holes as the gaskets may be damaged and thus cause leakage The warranty is not valid for damage caused by drilling through the mounting holes e Run the Nexus Network cable from the Server to the instrument
38. e with the following formula True distance from the sea chart T T Log trip counter distance L xC The current calibration value C L New calibration value N If you suspect a current in the water drive the boat in both directions and divide trip counter distance by two If the Wind Data is installed with Nexus Server where the log is already calibrated no further calibration is needed 25 5 CALBRATION 4 2 3 C23 Unit for temperature Select degree Celsius C or degree Fahrenheit F 4 2 4 C24 Temperature offset By adding a positive or negative value here it will be added as an offset before displayed as the temperature 4 3 C30 Compass Settings To return to normal mode press KEY when the text rET is displayed 4 3 1 C31 True or magnetic course This function is only used when the instrument is connected in the Nexus Network MAG On will display bearing course and Wind direction as magnetic The LCD indication is MAG Select OFF to display all as true 4 3 2 C32 Magnetic deviation Set the deviation direction first i e E East W West then enter the magnetic value in 1 10 of a degree 4 3 8 C33 Reference for Compass static or GPS Select heading Compass Hdc when the Compass transducer is connected to the Nexus Network recommended Select course over ground COG when a GPS navigator is connected but no Compass Select STA for static use at fixed ins
39. er One red and one black power wire is included Note set C71 On see 5 5 1 Always connect a 3 AMP fuse between Power supply and Green Yelow White 1 3 Soyer in Nexus Network If you already have a Nexus Network i e a Server it is more practical to connect the transducer to the Server due to the single instrument cable installation Note set C71 OFF see 5 5 1 Transducer SCREEN 12 GREEN 13 YELLOW 14 WHITE 15 SCREEN 16 The instrument is then connected to the Server s Nexus Network terminal pin 5 6 7 and 8 or any instrument 2 INSTALLATION From log transducer 14 Connection of log transducer NEXUS star D 20 If you have an other log instrument i e a 2200 220 0 log 2200 log or a 220 log you may connect _ re from that instrument to the Wind Data instrument terminal 4 3A Fuse If you don t have a log instrument but want to install a log transducer use the connection box Art no 21453 GREEN 2 YEL 35 INSTRUMENT From Server or other NEXUS instrument TRANSDUCER LE o 3 FIRST START 2 First start only in a Nexus Network 24 lnitialising the instrument At power on the instrument will perform a self test The display will first show all segments then the software version number and the Nexus Network ID number At first power on after installation you will be asked to press KEY PrSKEY This will give th
40. er for the push button 19763 4 5 5 C74 Demo mode The Wind Data instrument has a built in demonstration mode All values E p are simulated in this mode It is convenient to learn the functions of the instrument by using this mode Every 7th second the text DEM will appear to alert you that demo mode is selected 30 6 MAINTENANCE AND FAULT FINDING 5 Maintenance and fault finding 5 1 Maintenance Do not use detergents or high pressure washing equipment e At least once a year check all your connections and apply additional silicon paste at each connection point Always use the instrument cover for protection when not in use e Storing transducers and instruments when in use for longer periods It is advisable to remove the instruments and transducers and store them inside the boat or at home in room temperature if possible e To clean the instrument use only mild soap solution and rinse with water 5 2 Fault finding Before you contact your Nexus dealer and to assist your dealer to give you a better service please check the following points and make a list of e All connected instrument and transducers including their software version numbers e Instrument software version number e Nexus Network data bus ID numbers for each instrument displayed at power up 5 2 1 General In most cases the reason for faults in electronic equipment is the installation or poor connections Therefore always fi
41. er vindvinkel och vindhastighet att kompenseras i motsvarande grad f r att ka noggrannheten Denna givare var inte tillg nglig d denna manual skrevs 5 4 9 Inst llning av langskeppslutning offset C69 Denna inst llning r endast tillg nglig om Roll r valt i C73 du m ste l mna kalibreringsl ge och g in igen Inst llning av l ngskeppslutning offset Montera f rst givaren enligt instruktion justera d refter offset s att Pitch visar 00 n r b ten ligger lodr tt dvs l ngskeppslutning r 00 Genom att ange framf r v rdet kommer visad och uppm tt l ngskeppslutning att minskas med motsvarande v rde N r offset anges utan tecken kommer v rdet att adderas till uppm tt kr ngning N r givare anslutits kommer vindvinkel och vindhastighet att kompenseras i motsvarande grad f r att ka noggrannheten Denna givare var inte tillg nglig d denna manual skrevs 5 5 Konfigurera Nexus C70 F r att terg till normaldrift tryck NYCKEL n r rEt visas CONfigurering anger Du var vind och loggivare anslutits Detta n dv ndigt eftersom b de Wind Data instrumentet och Nexus Server kan sprida information om vind och fart Ett Wind Data instrument som anslutits till Nexus n tverk kan ta information om b de vind och fart fr n Nexus n tverk eller fr n givare som anslutits direkt till instrumentet Informationen s nds d vidare till vriga Nexus anslutna instrument 68 5 INST
42. era att givaren fungerar M t mellan skruv 4 och jord alla anslutningar m ste vara gjorda ta upp givaren ur genomf ringen Vrid l ngsamt p paddelhjulet halva varvet skall voltm taren visa OV och halva varvet 5V Vid hoppiga v rden kontrollera d mpningen SEA se C11 5 1 1 Felmeddelanden F ljande felmeddelanden kan uppst ERROR 2 Inget Nexus N tverk kontrollera anslutningar ERROR 3 L ngt uppeh ll i data verf ringen kontrollera kablar och Id nummer ERROR 10 ogiltigt V rde t ex 420 ERROR 11 Fj rrkommando som inte kan utf ras 72 7 SPECIFIKATIONER Svenska 7 Specifikationer 7 1 Tekniska specifikationer Dimensioner Wind Data instrument 110 x 110 mm Givarkabel 25m Sp nning 12V DC 10 16V Instrumentet skyddat mot f rv xling av batteripoler Str mf rbrukning Instrument 9 mA med max belysning 90 mA Vindgivare 25 mA Logg och temperaturgivare 15 mA Temperaturomr de Lagring Fr n 30 C till 80 Anv ndning Fran 10 C till 70 C Vikt instrument 283 g Vikt givare 293 g CE godkannande Alla produkter uppfyller EMC kraven f r immunitet och emission Enligt EN 50 08 1 and EN 55022 7 2 Nexus Natvark Introduktion Nexus N tverket ar en dubbelriktad buss med m jlighet att ansluta manga instrument Den ar en RS 485 duplex bus med m jlighet till 32 instrument anslutna samtidigt Den h ga st rokansligheten medger anv ndande av mycket l nga ka
43. et Adderar inst llt offset v rde till uppm tt v rde som d refter visas p displayen Eventuellt minustecken v ljs med minus framf r siffran 5 3 Inst llning av kompass F r att terg till normaldrift tryck NYCKEL n r rEt visas 5 51 Inst llning sann eller magnetisk kurs C31 G ller endast Nexus n tverk V lj On f r att visa magnetisk b ring kurs och vindriktning indikeras MAG V lj OFF f r att visa sann b ring kurs samt vindriktning Kan vara intressant om man har mycket stor missvisning p platsen 5 3 2 Inst llning av missvisning C32 St ll in missvisning E eller W f rst d refter storleken p den lokala magnetiska missvisningen Inst llning medges med 1 decimals noggrannhet vilket ger en korrekt avrundning efter kompensation 5 3 3 Inst llning av kurs referens N r kompassgivare r ansluten till Nexus n tverk Rekommenderas att den V ljs som referens V lj HDC V lj COG kurs ver grund n r GPS navigator r ansluten men ej kompassgivare V lj STA f r statisk anv ndning Anv nds vid fasta installationer sommarstuga skidanl ggning f rjel ge mm f r att visa geografisk vindriktning och vindhastighet Givaren monteras i riktning norrut men om detta inte r m jligt justeras givaren elektroniskt i Inst llningar med ADJust till att visa geografiskt riktigt Observera att COG dvs kurs ver grund endast kan fungera till
44. f ste 9 Fyll i garantikortet du har kontrollerat att alla ovanst ende artiklar finns med i f rpackningen ber vi dig att fylla i garantikortet och skicka det till generalagenten Genom att skicka in garantikortet hj lper du oss att ge dig snabb och korrekt hj lp om det uppst r problem med produkten Beh ll alltid ditt ink pskvitto Du kommer ocks att bli registrerad i v r utskickslista s vi kan n dig med information nyheter mm 44 Svenska INNEH LL I F RPACKNINGEN a es ane NEXUS NEE is 93 ART 20440 2 3 NEXUS NEXUS WIND 2 ata NATIONAL NEXUS DISTRIBUTORS WARRANTY CARD 6 INSTALLATION and OPERATION MANUAL D 4 45 2 INSTALLATION Svenska 2 Installation Du kan installera Wind Data instrumentet tre olika s tt e Anslut vindgivare direkt till Nexus Wind Data instrumentets skruvterminal e Anv nd kopplingsboxen tillbeh r f r att koppla in givare spanning och trimknappar En kabel g r fr n boxen till instrumentet e Anslut Nexus Wind Data i ett befintligt Nexus n tverk Installationen best r av sex steg 1 L s kapitlet om installation i manualen Planera var instrument och givare skall sitta Dra kablarna Installera givare och instrument Ta en paus och beundra din installation L r dig funktionerna och kalibrera instrumente
45. fredsst llande n r b ten g r fart genom vattnet 66 5 INST LLNINGAR 5 4 Inst llning kalibrering av vind C50 F r att terg till normaldrift tryck NYCKEL n r rEt visas 5 4 1 5 4 2 Nexus Inst llning sann eller relativ vindvinkel C51 V lj mellan skenbar AWA eller sann TWA vindvinkel denna inst llning p verkar de analoga vindrepeatrarna samt de Multi instrument som har WIA i sin systemsetup C63 Inst llning C51 r identisk med Multi Control inst llning C51 Val av enhet f r vindhastighet C52 Enheten f r vindhastighet kan v ljas mellan KTS f r knop m s f r meter s samt BF f r Beufour 5 4 3 5 4 4 b tens motor st ller Du C54 till 356 det samma sak som att dra ifr n 49 54 5 C55 C56 C57 C58 C59 C60 c61 Vindhastighets kalibrering C53 Detta v rde r fabriksinst llt p 1 50 och beh ver d rf r inte ndras Justering av visad vindvinkel C54 Justering av mindre vinkelfel efter montering av givaren eller n r vindgivaren avsiktligt placerats t ex 90 vinkelr tt mot masten Inst llt v rde adderas till vindvinkeln Exempel om vindvinkeln visar 4 n r Du g r rakt mot vinden med Kalibreringstabell f r vindgivaren C55 C62 Se medf ljande kalibrerings certifikat F r varje 45 intervall anges ett korrektionsv rde V rdet matas in under respektive angivet intervall Efter kalibrering r vinkelfelet max 1 5 000 045 0
46. horizontal segment when actual angle is equal to the pre set angle At the same time you will see apparent and true Wind angle The deviation is displayed visible upwards or downwards from the horizontal line to 15 The maximum visible deviation is 15 When the deviation is between 15 and 30 the 15 sector is lit When larger then 30 the segment sector is blanked out Trim on speed Pilot MEN Select the trim function Press UP and DOWN together Select text BSP by pressing UP and 26U SE confirm with KEY There is a number of different speeds to be used for trimming The most common is BSP Boat SpeeD and VMG Velocity Made Good The Wind Data instrument can also display deviation from optimum TRT calculated boat speed TBS or Target Boat Speed n The TBS is normally calculated by use of polar diagram on PC with racing software The value Target Boat Speed is transmitted through the Nexus Server on the NMEA 0183 input The Server will then transmit TBS on the Nexus Network On the Wind Data display you will see both the digital value in and the graphical value as a 296 variation for each segment You may select speeds to TRIM from this list BSP Boat speed Log transducer AWS Apparent Wind Speed TWS True Wind Speed Log transducer SOG Speed Over Ground Navigator 17 4 OPERATION DRF Drift Log transducer Compass Navigator WCV Speed towards a waypoint Navigator
47. idigt p UPP och NER s att displayen blinkar V lj t ex BSP med UPP och avsluta med NYCKEL Det finns olika hastigheter att trimma mot De vanligaste r b tfart vattenhastighet och VMG Wind Data instrumentet kan ven visa avvikelse fr n optimal b tfart TBS som ber knas med hj lp av ett program f r PC d r TBS f s ur ett polardiagram f r just din b t Information om Target Boat Speed s nds fr n PC till NMEA 0183 ing ngen Nexus Server som i sin tur s nder ut TBS Nexus n tverk Wind Data displayen kan Du se trim i 96 b de digitalt och grafiskt Varje segment motsvarar 295 Du kan v lja hastigheter att trimma mot ur f ljande lista BSP Vattenhastighet Loggivare AWS Skenbar vindhastighet TWS Sann vindhastighet Loggivare SOG Fart ver grund Navigator DRF Drift Loggivare Kompass Navigator WCV Fart mot aktivt etappm l WP Navigator VMG Fart mot eller med vinden Loggivare TBS Optimal hastighet enligt polardiagram PC NMEA 0183 via Nexus Server OFF Funktionen avst ngd 58 4 FUNKTIONER Svenska Efter t ex val av BSP visas d mpning 90 blinkande v lj d mpning och tryck nyckel Texten BSP OFF visas vilket inneb r att referens saknas Tryck nyckel f r att s tta BSP referens Displayen visar nu 96 v xelvis med texten BSP samt hastighetsavvikelsen uttryckt i 96 Tryck p NYCKEL varje g ng Du vill s tta en ny referens hastighet att tr
48. ight Instrument 283 g 9 98 oz Transducer 293 g 10 33 oz Enclosure Instrument Water proof CE approval The products conforms to the EMC requirements for immunity and emission according to EN 50 08 1 6 2 Nexus data bus introduction and user policy Introduction The Nexus data bus is a Multi talker Multi receiver data bus specially designed for marine navigation applications It utilises the RS485 standard with up to 32 senders and or receivers to form a Local Area Network Data is transmitted synchronously with 1 start bit 8 data bits 1 parity bit two stop bits in 9600 baud User policy The Nexus data bus is open for new users and applications without the licence or a licence fee The data bus however is the property of the manufacturer which means the specification must be followed in order to protect the manufacturers commitments to the Nexus data bus performance and safety For most PC applications the full duplex interface Art No 21248 will be a very useful tool for monitoring real time data to edit and store Waypoints to PC file or to Server and or to the Nexus GPS The interface 33 is supplied with a cable for connection from PC to the Server or Nexus instruments and or the Nexus GPS A 9 pole D sub connector is connected to the RS232 port on the PC 34 8 OPTIONAL ACCESSORIES 7 Optional Accessories Below find a selection of optional accessories available Please contact your local Nexus dealer
49. imma mot Du kan ven ansluta en yttre trimknapp f r att s tta ny trimreferens 5 ga Varje sektor motsvarar 2 4 6 Funktioner med Wind Data i Nexus n tverk Genom att ansluta Wind Data instrumentet till Nexus n tverk kan flera nya funktioner aktiveras under f ruts ttningen att motsvarande givare eller navigations information finns tillg nglig Wind Data instrumentet har flera till ggsfunktioner som kan aktiveras av anv ndaren se i inst llningar f r att passa kappseglare s v l som och familjeseglare Wind Data kan anv ndas i ett litet n tverk tillsammans med Multi Log eller analoginstrumenten F r att underl tta installation i ett litet n tverk rekommenderas kopplingssats Art nr 21453 Anslutning av b de vind och loggivare sker samlat vid t ex mastfoten D refter g r endast en kabel fram till Wind Data med signaler och sp nning Till Wind Data kan Du nu enkelt ansluta t ex ett Multi Control instrument N r Nexus Wind Data skall anv ndas i ett st rre Nexus n tverk med fler n 3 givare log wind ekolod rekommenderas att givare ansluts till Nexus Server Endast en kabel beh vs f r att verf ra b de sp nning och data till samtliga instrument Dessutom ing r ett NMEA 0183 kommunikations interface f r anslutning av annan navigationsutrustning Skall t ex djupinformation visas p flera instrument m ste ekolodsenheten vara ansluten till Nexus Server Bonusfunktion Om Du anv
50. ion 5 2 Kalibrering LOG C20 F r att terg till normaldrift tryck NYCKEL n r rEt visas 521 enhet C21 V lj enhet f r fart knop KTS km h K h eller miles h m h 5 2 2 Kalibrering av loggivare C22 Det r viktigt att Du kalibrerar b tfarten noggrant och n r detta v l r gjort lagras v rdena i instrumentets avbrottsfria minne Har Du redan r tt kalibreringsv rde i ditt Nexus Speed instrument kan samma v rde anv ndas i Wind Data Beh ver Du g ra en ny kalibrering m ste Du v lja tillval C13 BSP till On f r att kunna se b tfart och triplog K r b ten en distans i normalfart och j mf r sedan med den distans som trippm taren visar Ber kna d refter din bats kalibreringsvarde med f ljande formel Sann distans fr n sj kortet T T Loggad distans L xC N Nuvarande kalibreringsvarde C L Nytt kalibreringsvarde N Om du misst nker str m i vattnet under kalibreringen b r Du k ra i b da riktningarna och d refter dividerar Du m tt distans med 2 f r att eliminera p verkan av str mt vatten Om Wind Data installeras med Nexus Server d r b tfart redan kalibrerats beh ver ingen ny kalibrering g ras 65 Svenska Svenska 5 INST LLNINGAR 52 3 Inst llning av enhet f r vattentemperatur C23 5 2 4 V lj enhet f r temperatur grader Celsius C eller grader Farenheit F Inst llning av vattentemperatur offset C24 Inst llning av temperatur offs
51. it will be added When a roll transducer is connected the Wind speed and angle will be compensated for roll and accuracy is increased The roll sensor is not yet available at the time for this manual 4 4 9 C69 Pitch adjustment This adjustment is valid only if roll is selected in C73 you have to exit and enter the calibration again after C73 is set to Roll Adjustment of the pitch offset Mount the pitch transducer according to the instructions Adjust the offset so the pitch is displaying 00 when the boat is horizontal By entering a minus sign in front of the value the roll will be decreased by the value When the offset is without a minus sign it will be added When a pitch transducer is connected the Wind speed and angle will be compensated for pitch and accuracy is increased Pitch does not affect Wind speed and angle as much as roll 4 5 C70 Configure Nexus 28 5 CALBRATION To return to normal mode press KEY when the text rET is displayed In the configuration you will be able to tell the Nexus Network where you have installed the log and Wind transducer This is important because you may optionally install those transducers at the Server too 4 5 1 C71 Wind master On the Wind transducer is connected at the Wind Data instrument OFF the Wind transducer is connected at the Nexus Server 4 5 2 C72 Log master On the log transducer is connected at the Wind Data instrument OFF the l
52. n certificate supplied with each mast top unit Each of the inter cardinal directions are calibrated C55 000 000 C56 045 045 C57 090 090 Set the calibration value according C58 135 135 to the provided calibration certificate 27 5 CALBRATION C59 180 180 C60 225 225 C61 270 270 C62 315 315 4 4 6 C63 Speed reference water or GPS This function is only used when the instrument is connected in the Nexus Network When BSP is selected the reference is water speed provided by the log transducer for calculation of true Wind speed and angle VMG and NXT function together with the BTW When SOG is selected the reference is speed over ground Note the boat must be moving to give correct readings We also recommend you to use differential GPS to get good readings 4 4 7 C64 Wind trim reference This default reference for Wind angle trim Each time the instrument is powered up and apparent Wind angle is selected as trim reference this value will be pre set 4 4 8 C68 Roll adjustment This adjustment is valid only if roll is selected in C73 you have to exit and enter the calibration again after C73 is set to Roll Adjustment of the roll offset Mount the roll transducer according to the instructions Adjust the offset so the roll is displaying 00 when the boat is horizontal By entering a minus sign in front of the value the roll will be decreased by the value When the offset is without a minus sign
53. n vindvinkel TWA True Wind Angle om loggivare ansluten Sann vindhastighet TWS True Wind Speed om loggivare ansluten F r att v xla mellan dessa funktioner se C12 5 1 2 Visas ett minus tecken framf r AWA eller TWA inneb r det att vinden kommer in p babords sida 4 4 Analogfunktioner 180 f r att v xla mellan 180 och 60 vindskala tryck p FUNKTION Inst llt val markeras av en pil under motsvarande vald skala APP Texten APP visar att huvudfunktionen r satt att visa relativ vindvinkel eller vindhastighet motsatsen r sann tru Se inst llningar C12 5 1 2 MIX 180 Texten MIX 1807 visar b de relativ och sann vindvinkel samtidigt utan uppf rstoring MIX 60 Texten MIX 60 visar relativ och sann vindvinkel samtidigt i uppf rstorad skala closed hauled Denna funktion g r att anv nda b de under kryss och undanvind Den analoga skalan kan v xlas mellan 180 och 60 f r att f h gre uppl sning Vid 180 r varje sektor 5 vid 60 r varje sektor 1 Se exemplet nedan VIND True wind angle TWS e gt Aem wind angle SC g AWA eR True wind angie TWA Apparent wind angle 55 Svenska 4 FUNKTIONER 4 5 Underfunktioner V lj underfunktion med UPP eller NER Ledtext till underliggande information visas i den mittersta raden utom vid funktionsbyte av analog visning d informationstext om vald analogfunktion visas blinkande under t
54. ned in the text it will be in brackets and the same format where possible as displayed e g AWA e This manual has been written to be Compatible with Wind Data instrument from software version 1 0 e All functions followed by the text option is not valid a factory set up instrument See calibration to be able to display these functions Note We have put down a lot of effort in order to make this manual correct and complete But since we continuously make our products better some information can differ from the products functions If you need further information contact your national distributor 11 4 OPERATION 3 2 How to use the 4 push buttons APPARENT MAIN INFOTEXT TRUE WIND ANGLE SUB TRIM FUNCTION DOWN UP 3 2 1 MODE A press on MODE change the mode of the graphical display It scrolls in a circular pattern one step for every press The MODE button is also used to move the cursor when in edit mode A press on MODE moves the cursor in a circular pattern one step to the right for every press A press on MODE and DOWN together back steps cursor to the preceding step When in editing mode a long press gt 2sec on MODE will escape from that editing mode 3 2 2 DOWN A press on DOWN moves to the next sub function In edit mode it decreases to previous digit 3 2 3 UP A press on UP moves to the previous sub function In edit mode it increases to next digit 3 2
55. ningar och kablar n gon g ng om ret 6 2 Fels kning Innan du kontaktar Nexus agent vill vi att du kontrollerar en del saker Detta f r att vi skall ha m jlighet att ge bra service e Vilka instrument som r kopplade till Nexus N tverket med dess versionsnummer e Nexus N tverksenhets nummer f r alla instrument 6 2 1 Fels kning generellt e Feli elektronisk utrustning beror ofta p felaktiga anslutningar eller inst llningar Att installationen r gjord enligt instruktionerna Att alla skruvanslutningar r v l tdragna Att inte korrosion uppst t i anslutningar Att det inte r kontaktfel i anslutningarna Att batterisp nningen r korrekt Att s kringen inte har br nt och Att r tt typ av s kring anv nds Att inte tv instrument har samma Id nummer p Nexus N tverket Att f ljande viktiga inst llningar r korrekta C13 C14 C33 C63 C71 och C72 71 Svenska 6 UNDERH LL 6 2 2 Fel tg rd 1 3 Vindfunktioner Om vingivaren ger felaktiga eller hoppiga v rden kontrollera anslutningar om d ckgenomf ringskontakt anv nds kontrollera den Mat med en voltmatare mellan skruv 1 och jord samt skruv 2 och jord v rdet skall ligga mellan 1 5V till 4V m t endast vid vindhastighet ver 3 m s Om voltm taren visar OV eller 5V r givaren eller anslutning felaktig m t endast vid vindhastighet ver 3 m s Fartfunktioner C13 skall st i on Med en voltm tare kan man kontroll
56. od byta ut felaktiga returnerade produkter under garantiperioden med n rmast motsvarande ers ttningsprodukt GARANTIPROCEDUR Produkten skall returneras till Tillverkaren tillverkarens distribut r eller terf rs ljare i det land d r produkten ink pts Giltiga garantikrav kommer d att ers ttas utan kostnad Alternativt kan produkter som anv nds i annat land n ink pslandet l mnas in till den lokala nationella distribut ren eller terf rs ljaren Giltiga garantikrav kommer d att ers ttas utan kostnad Giltiga garantikrav kommer ven d att ers ttas i form av reservdelar men arbetstid och eventuellt tillkommande kostnader f r frakt kommer att debiteras k paren i enligthet med g llande priser F RBEH LL Sunt f rnuft g ller vid anv ndning av navigationsutrustning och tillverkarens produkter skall endast ses som ett navigationshj lpmedel Tillverkaren f rbeh ller sig r tten att ndra produktens specifikation 77 Svenska 10 GARANTI Fil id GARANTIKORT 2224 SKICKAS TILL GENERALAGENTEN GARE Namn Adress Postnummer Land Produktens namn Serie nummer A B O O O gO O 0 OO O 0 0 des EJEJEJEJBJEIS LILJLIEIDIET Ink psdatum Installationsdatum Aterf rsaljarens st mpel Kryssa har om du inte intresserad av information om nya produkter 78
57. og transducer is connected at the Nexus Server 4 5 3 C73 Function on terminal In3 Select function on the terminal pin 3 The following functions are available TMP Standard temperature function from the log transducer TRM Use the external trim button for the STEER Pilot function SPT Use the external trim button for the SPEED TRIM function MOB Use the external trim button for the M O B function Roll Use the roll sensor to compensate Wind speed and angle Not yet available at the time for this manual When the selection roll is made further settings in calibration can be made to correct the offset angle See C68 5 4 8 You may still use the water temperature by connecting the log transducer at the Server When Speed Trim SPT is selected a press on the external trim button will transmit the trim command on the Network to all instrument To be able to set both the STEER reference and the TRIM reference the optimum way is to connect one trim button for speed to the Wind instrument and connect one trim button for Compass and Wind angle to the Server Such a installation gives you the opportunity to trim speed and angle at two separate buttons 4 5 4 Connecti on of trim button Connect the trim button as per the drawing The button should make connection when pressed It is also possible to connect more than one button in parallel for example one on 5 CALBRATION starboard and one on port Article numb
58. portant The functions BTW and NXT is toggling but can be locked or unlocked by use of the KEY Note This function is only used on the last leg WIND 23 5 CALBRATION 4 Calibration To get the most out of your Nexus instrument it is important to carefully calibrate the instrument The calibration values are stored in a non volatile memory To access calibration mode press and hold KEY more than 2 seconds To select a calibration code press DOWN UP and MODE as required To return to normal operation mode press KEY when the text return RET is displayed The different calibration routines are divided into five groups C10 C15 USR User settings C20 C24 BSP Log transducer and temp calibrations C30 C33 HDC Compass settings C50 C64 WND Wind transducer settings calibrations C70 C74 CON Configuration of the Nexus system To change a calibration value press KEY To select calibration value press DOWN UP and MODE as required To lock the selected value press KEY 4 1 C10 User settings To return to normal mode press KEY when the text rET is displayed 411 C11 Select the dampening The dampening will affect Wind angle Wind speed boat speed and VMG Dampening is between dO 0s and d9 1 20 To change the dampening press KEY and change with UP or DOWN and enter with KEY 4 1 2 C12 Select main information Select function to be display at the top left of the LCD displa
59. pressing UP and DOWN together 3 5 8 Water temperature TMP option The text TMP is displayed with water temperature in Celsius or Fahrenheit This function require a Nexus or Star log transducer 3 5 9 Trim function for optimum Wind angle or speed option The text TRM and OFF is displayed when this function is off The trim function can be used as an aid to keep the correct tacking angle or to discover speed changes caused by sail or rig trimming Some of the functions can only be used when the Wind Data is connected to Nexus Network As the first example we will use TRM AWA TRiM Apparent Wind Angle To trim on Wind angle deviation select the text Press UP and DOWN together the display will flash Select AWA with DOWN and confirm with KEY 16 4 OPERATION Select the level of dampening 90 09 and confirm with the KEY The default or latest used Wind angle is displayed You may accept the proposed angle by pressing the KEY or enter a new Wind angle with UP DOWN and MODE before confirming with KEY The entered Wind angle will be lost when power off You may however select a default Wind angle in set up See C64 5 4 7 Every time you select this function or after power up the pre set value is proposed On the display you will see the text TRM and AWA toggling together with your Wind angle On the graphic part you will see your reference angle as Each sector represents 2 one straight
60. r ej f r instrument med borrskadade monteringsh l e Dra fram instrumentkablar till instrumentens innan anslutning enligt punkt 4 sker e Kapa och skala bort ca 3 4 cm av ytterisoleringen d refter skalas de tre isolerade ledarna ca 6mm en av ledarna r blanktr d Kl m fast de extra Andhylsorna p ledarna med en platt ng innan Du ansluter den till skruvterminalen Dra instrumentkabeln om m jligt bakom b tens inredning e Innan den 4 poliga skruvplinten ansluts till instrumentet skall silikonfett appliceras samtliga kontaktytor OP SSA i OOOO Siliconfett Nar Du shi E Siliconfett SUN e Anslut d refter plinten till instrumentet och pressa ner kablarna i respektive kabelspar Skruva d refter fast tackkapan e Skruva fast instrumentet p skottet anv nd alltid samtliga 4 skruvar e Dra korsvis fast instrumentet mot skottet s att skottpackningen monterad p instrumentets baksida komprimeras till ca 1 3 del av sin ursprungliga tjocklek e Montera d refter de 4 runda gummipropparna f r att tata och d lja monteringsskruvarna e Anvand vid behov buntband till att klamra kablar Installationen r klar 47 2 INSTALLATION Svenska 2 2 Kabeldragning Sp nningskabel dras direkt och sa kort som
61. r visits to the boat to attend to the equipment whether under warranty or not The right is reserved to charge for such services at an appropriate rate The Manufacturer reserves the right to replace any products returned for repair within the warranty period with the nearest equivalent if repair within a reasonable time period should not be possible The terms and conditions of the warranty as described do not affect your statutory rights CLAIMS PROCEDURE Equipment should be returned to the national distributor or one of its appointed dealers in the country where it was originally purchased Valid claims will then be serviced and returned to the sender free of charge Alternatively if the equipment is being used away from the country of purchase it may be returned to the national distributor or one of its appointed dealers in the country where it is being used In this case valid claims will cover parts only Labour and return postage will be invoiced to the sender at an appropriate rate DISCLAIMER Common sense must be used at all times when navigating and the Manufacturer s navigation equipment should only be considered as aids to navigation The Manufacturers policy of continuous improvement may result in changes to product specification without prior notice 38 10 WARRANTY File id WARRANTY CARD TO BE RETURNED YOUR NATIONAL DISTRIBUTOR OWNER Name Street City Zip Code Country Product name
62. ra bokst ver exempelvis UPP e Om det inte st r n got annat g ller korta tryck p knapparna e Varje g ng en funktion omn mns i texten skrivs den mellan klamrar och i samma format som p displayen Exempelvis VMG e Alla funktioner som f ljs av texten tillval r inte tillg ngliga pa ett fabriksinst llt instrument Se kalibreringskapitlet f r att f tillg ng till dessa funktioner e Denna manual r skriven f r Wind data instrument version 1 00 OBS Vi har lagt ner mycket m da p att f denna manual korrekt fullst ndig och enkel att f rst Emellertid utvecklar vi st ndigt v ra produkter vilket kan leda till att en del information kan avvika fr n produktens funktion Om du beh ver ytterligare information kontakta din terf rs ljare 52 4 FUNKTIONER Svenska 4 2 5 anv nds de fyra knapparna HUVUD SKENBAR FUNKTION VINDVINKEL LEDTEXT SANN VINDVINKEL UNDER FUNKTION TRIM FUNKTION FUNKTION NYCKEL NER UPP 4 2 1 FUNKTION Med FUNKTION v ljs funktion p den analoga delen skala 60 eller 180 eller endast geografisk vindvinkel tillval FUNKTION anv nds ocks f r att flytta mark ren det blinkande tecknet ett steg t h ger n r man befinner sig i redigeringsl ge Ett tryck p FUNKTION och NER tillsammans flyttar ett steg t v nster 422 Med NER stegar du ner t i underfunktionslistan I redigeringsl ge minskar du ett v rde 4 2 3 UPP Med U
63. ransducer When measuring with voltmeter make sure everything is connected that the power is on and make sure the paddle wheel is rotating e Atthe back of the instrument measure between pin 4 and ground e When not rotating the value should be fixed at either about 0 or 5 V DC When rotating very slowly by hand the value should flip between 0 and 5 V DC When rotating faster the value should average around 2 5 V DC Irregular values Check the speed damping SEA see C11 5 1 1 3 Compass functions No reading e C14 should be ON See 5 1 4 5 2 8 Error messages The following error messages can appear on the display ERROR 2 Nexus Network is missing check colour coded connections ERROR 3 No Network data received within a given time ERROR 10 Range error caused by bad format e g 430 ERROR 11 Remote command that can not be performed If other error messages than the above appears on the Wind Data instrument contact your Nexus dealer 32 7 SPECIFICATIONS 6 Specifications 6 1 Technical specifications Dimensions Wind Data instrument 110 x 110 mm 4 3x4 3 inch Instrument cable Power supply 12 V DC 10 16 V The instrument is polarity protected Power consumption Instrument 0 08 W 0 8 W at max illumination Log and temp sensor 12 mW Wind transducer 50 mW Temperature range Storage From 30 C to 80 C 22 F to 176 Operation From 10 C to 70 C 14 F to 158 We
64. rst check that e Installation and connection is made per instructions for instrument and transducers see 2 1 Screw terminals are carefully tightened No corrosion on any connection points No loose ends in the wires causing short cuts to adjacent wires Cables for damage that no cables are squeezed or worn Battery voltage is sufficient should be at least 10 V DC The fuse is not blown and the circuit breaker has not opened The fuse is of the right type Two instruments do not have the same ID number see 3 Check the following important settings C13 C14 C33 C63 C71 and C72 31 6 MAINTENANCE AND FAULT FINDING 5 2 2 Fault action 1 Wind No reading e f inaccurate Wind data is received check the connections separate through deck connection or below decks connection are properly made e Make sure the transducer is aligned correctly see C54 5 4 4 e Measure with a voltmeter at the screw terminal pin 1 and ground and between pin 2 and ground e If the voltmeter shows 1 5 to 4 V DC minimum Wind speed m s at both measuring points the transducer and the connections are OK e If the voltmeter shows 0 or 5 V DC at both measuring points the transducer or the connections are defect Contact you Nexus dealer with this information 2 Speed and distance functions No reading C13 should be ON See 5 1 3 e f you have a voltmeter available you can check the condition of the t
65. s Maxi repeater via NMEA red digits Single bracket for Maxi repeater Double bracket for Maxi repeater Nexus FD interface PC interface with 1 m 3 3 ft cable Includes 377 disc with software for waypoint editing and a data bus manager and NMEA interface Push button for Tactical and MOB function High Speed Paddle wheel up to 40 KTS Internal mounting kit for depth transducer Bronze through hull fitting Instrument panel in aluminium for up to 6 Nexus instruments Through deck connector 7 pole Through deck connector 4 pole Connector 4 pole 15 angle adjustment for mast top bracket Connection box for Wind instrument 36 9 ABREVIATIONS 8 Abbreviations BSP Boat Speed BTW Bearing To Waypoint C Celsius F Fahrenheit KM KiloMetre KTS KnoTS MH Miles per Hour LCD Liquid Crystal Display LOW LOW MID MID MAX MAX RET RETurn SOG Speed Over Ground TRP TRiP Minus Plus 37 0 WARRANTY WARRANTY GENERAL All our products are designed and built to comply to the highest class industry standards If the products are correctly installed maintained and operated as described in the installation and operation manual they will provide long and reliable service Our international Network of distributors can provide you with the information and assistance you may require virtually anywhere in the world Please read through and fill in this warranty card and send it to your national distributor for product registration LI
66. s genomf ring Instrument panel i aluminium f r upp till 6 Nexus instrument Decksgenomf ringskontakt 7 polig Decksgenomf ringskontakt 4 polig Skarvkontakt 4 polig l mplig f r fj rrkontroll 15 vinkel adapter f r masttopps f ste Kopplingsbox for Wind instrument 75 Svenask 9 F RKORTNINGAR 9 F rkortningar F rkortning ADJ APP AWA AWS BAT BSP BTW C C10 CAL CON DEM F HDC KM KTS LCD LOW m MAG MAX Mh MID MIX NAV NXT RET SEA SOG STA TMP TRM TRP tru TWA TWD TWS Unt USR VAR VMG WCV WIA WND XTE Engelsk beskrivning ADJust APParent Apparent Wind Angle Apparent Wind Speed BATtery Boat Speed Bearing To Waypoint Celcius Calibrate 10 Calibrate CONfiguration DEMonstration Farenheit HeaDing Compass Kilometer per hour KnoTS Liquid Crystal Display LOW Metre MAGnitic MAX Miles per hour MID NAVigation NeXT RETurn Sea Speed Over Ground STAtic TeMPerature TRiM true True Wind Angle Sann vindvinkel True Wind Direction True Wind Speed Sann vindhastiget Unit USeR VARiation Velocity Made Good Waypoint Closure velocity Wind Angle WiND calibration Vindkalibrering Cross track error Minus Plus Svensk vers ttning Justera Skenbar Skenbar vindvinkel Skenbar vindhastighet Batteri B tens fart B ring till etappm l Celcius Kalibrering 10 Kalibrering Konfiguration Demonstration Farenheit Styrkompass
67. t FAR VIL Innan Du b rjar borra Planera f r placering av givare och instrument s att avsedd funktion uppfylls och att kabeldragning blir enkel Om Du t nker anv nda Wind Data i ett Nexus n tverk med flera instrument b r Du nu best mma om vindgivaren skall installeras i instrumentet eller i Nexus Server L s mer i kapitel 2 3 T nk p Kapa inte kablarna f r korta extra kabell ngd underl ttar vid inspektion Anv nd inte sillikon eller liknande bakom instrumentet Instrumentets packning r cker f r att t ta Dra inte kablarna i k lsvinet om de d r kommer att ligga i vatten Dra inte kablar f r n ra lysr r generator eller radioutrustning Stressa inte ta god tid p dig En snygg installation r enkel att g ra F ljande material beh vs Avbitare och skalt ng Stor och liten stj rnskruvmejsel instrumentskruvmejsel H ls g f r instrumentets kopplingstorn 63 2 8 mm borr f r monteringsh l i tr 3 2 mm borr f r monteringsh l i glasfiber Om du r os ker p installationen kontakta en marintillbeh rsinstallat r 46 Svenska 2 INSTALLATION 2 1 Installation av instrument e Instrumentet r avsett f r utanp liggande montering och skall monteras framifr n p en j mn och plan yta Anv nd alltid den medf ljande borrmallen vid monteringen Borra aldrig genom instrumentets monteringsh l eftersom packningarna kan skadas och d rmed g ra instrumentet ot tt Garantin g lle
68. t Wind shift you will see this marker as a slow blinking reminder of the origin Wind direction hifts by entering 3 6 2 WCV Waypoint Closing Velocity To get this function set NAV On C14 See 5 1 4 The text WCV is displayed with the actual speed towards your Waypoint if a Waypoint is selected in your GPS navigator 3 6 3 X track error XTE To get this function set NAV On C14 See 5 1 4 The text XTE is displayed shortly when this function is selected then a symbolic boat is displayed on one side of the road which is displayed as three vertical lines 19 Your boat will be displayed on the right or left side of the road The distance is also displayed and can be in either Nautical mile Km or Miles 20 4 OPERATION 3 6 4 NXT Course after tack or jibe To get this function set NAV On C14 See 5 1 4 This function also needs a Compass connected to the Nexus Server If the Compass sensor is missing the HDC may be replaced by the COG Course over ground by setting the reference in COG See C33 5 3 3 The text HDC is displayed with actual magnetic or true heading After 4secs the text NXT together with the true or magnetic course to keep after tack or jibe Note The boat s drift must be included in your decision when to tack to reach the mark After a tack it will take some minute before the new tack angle is steady due to the dampening The functions HDC and NXT
69. t alla segment d refter visas versionsnummer och enhetsnummer p Nexus bussen N r givaren r ansluten till instrumentet har instrumentet ett fast enhetsnummer nr 9 Efter den f rsta uppstarten efter installationen blir du ombedd att trycka p en knapp PrESKEY Detta kommer att ge instrumentet ett enhetsnummer Nexus bussen Detta kommer endast att ske om flera Nexus instrument inkopplade bussen OBS Om fler instrument nyinkopplade N Nexus bussen m ste du v nta p texten Init OK innan du trycker p n sta instrument Den enhet som r bussadministrat r Nexus Server eller Wind instrumentet kommer att ge det f rsta instrumentet enhetsnummer 16 n sta 17 osv Bilden till h ger visar att instrumentet har versionsnummer 1 00 och enhetsnummer 16 3 2 Ominitialisering av ett instrument Om flera instrument av misstag har f tt samma enhetsnummer m ste de initialiseras om F r att g ra detta tryck UPP och NER samtidigt n r displayen visar versions och enhets nummer Alla instrumenten utf r du en sj lvtest och verg r sedan till att visa texten PrESKEY F lj anvisningarna ovan OBS Om det r problem att g ra en ominitialisering koppla d bort alla instrument utom ett som har samma enhetsnummer 51 Svenska 4 FUNKTIONER 4 Funktioner 4 1 denna manual e Varje g ng det refereras till en knapptryckning i denna manual kommer namnet att st i fet text med sto
70. tallations such as at the yacht club airfield ferry berth and so on In static mode you may mount the transducer in the direction of North or if not possible you may adjust the transducer electronically See C54 5 4 4 Note COG as reference will only operate properly when the boat is doing speed over ground 26 5 CALBRATION 44 C50 Wind Settings To return to normal mode press KEY when the text rET is displayed 4 4 4 C51 Network setting of true or apparent Wind angle Select true TWA or apparent Wind angle AWA as main function The optional analogue Wind instrument will display the same selection All Multi Control instruments which have the calibration code 63 set to WIA will display what is selected in C51 4 4 2 C52 Unit for Wind speed Unit for Wind speed KTS for KnoTS M S for Metres S and BF for Beaufort 4 4 8 C53 Wind speed calibration Do not change this factory setting 44 4 54 Adjustment of Wind angle Mast top unit misalignment adjust value or the so called A fault makes it possible to adjust any horizontal angle Example If the Wind angle is 4 when you sail drive the boat straight into the Wind set the calibration value in C54 to 356 4 4 5 C55 C62 Calibration table for the Wind transducer In channels C55 to C62 you set the calibration values for the mast top unit Each mast top unit is individually calibrated for best accuracy See the separate Wind calibratio
71. tappm l 23 4 6 3 Avvikelse fr n kurslinje 23 4 6 4 HDC NXT Kurs och kurs att h lla efter 51 9 23 4 6 5 BTW NXT Baring och vinkelavvikelse mot 23 5 Inst llningar 24 5 1 Anv ndarinst llning 10 24 5 1 1 Inst llning d mpning 11 24 5 1 2 Val av huvudinformation 12 24 5 1 3 Tillval b tfart logg samt vattentemperatur 13 24 5 1 4 Tillval av NAV funktioner 14 24 5 1 5 Ljudsignal vid knapptryckning 25 5 2 Kalibrering av LOG 20 25 5 2 1 Val av nhet C21 rtc e n e v e re rr ir V v rns 25 INNEH LL Svenska 5 2 2 Kalibrering av loggivare C22 essen 25 5 2 3 Inst llning av enhet f r vattentemperatur 23 25 5 2 4 Inst llning av vattentemperatur offset 24 25 5 3 Inst llning av kompass C30 eese 25 5 3 1 Inst llning av sann eller magnetisk Kurs C31 25 5 3 2 Inst llning av missvisning C32 eene 25 5 3 3 Inst llning kurs referens C33 25 5 4
72. v sekunder Du kan parkera vald kombination av funktioner s att de automatiskt visas vid uppstart Tryck samtidigt p FUNKTION och NYCKEL samtidigt och displayen blinkar till som kvittens att parkering utf rts 4 5 1 Relativ vindhastighet AWS Texten AWS Apparent Wind Speed och den relativa vindhastigheten visas Texten AWS visas v xlande med information om vald enhet Knop KTS Meter s M S eller Beufort BF 4 5 2 Sann vindhastighet TWS Texten TWS True Wind Speed och den sanna vindhastigheten visas TWS kompenserad f r b tens fartvind loggivare m ste vara ansluten Texten TWS visas v xlande med information om vald enhet Knop KTS Meter s M S eller Beufort BF 4 5 3 Maximal sann vindhastighet MAX Wy F r att se MAX uppm tt sann vindhastighet tryck pa NYCKEL Efter 7 ca 5sekunder terg r visningen automatiskt till TWS 235 Exemplet visar att max vindhastighet har uppm tts till 23 5m s eller annan vald enhet Du kan nollst lla MAX vindhastighet genom att samtidigt trycka p UPP och NER eller genom att bryta sp nningen 4 5 4 B tfart mot eller med vinden VIND Texten VMG Velocity Made Good och hastighet rakt mot eller rakt fr n vinden visas Kr ver loggivare eller att loggsignal byglas fr n t ex Nexus logginstrument Information om b tfart kan ven f s via Nexus n tverk VMG 0 0 knop n r Du seglar med sann 2
73. y There is five options AWA Apparent Wind Angle TWA True Wind angle by the use of log transducer AWS Apparent Wind speed TWS True Wind speed by use of log transducer WIA Main setting for the Nexus system When selected all instruments using WIA will be system affected and following the set up in the Multi Control setting C51 24 5 CALBRATION 4 1 3 C13 Displaying boat speed trip log and temperature option When set to OFF the functions will be removed from the display The Wind Data instrument may be used as a Server in the Nexus Network transmitting the log and temp to other Nexus instruments without having the information displayed in this instrument 4 1 4 C14 Display NAV functions option NAV functions are only useful when the Wind Data is connected in a Nexus Network with Compass transducer and a navigator The selection NAV On will add the functions as described under Nexus Network See 4 6 4 1 5 C15 Beep when key is pressed Setting On will make a beep at every key press while OFF is silent 4 2 C20 Calibration of Log To return to normal mode press KEY when the text rET is displayed 4 2 4 C21 Select unit for speed Unit for speed knots KTS km h K h or miles h m h 4 2 2 C22 Calibration of log transducer Calibration value for speed and distance 1 00 1 99 Drive the boat a measured distance at normal speed Compare the distance with the trip counter Calculate the valu
Download Pdf Manuals
Related Search
Related Contents
OPERATION & INSTALLATION MANUAL AIS RX CARBON & AIS CC Pilot XS - maximatecc support 1 - Sony Haier Freezer HCM071AW Service Manual Tarif TTC Adventure au MC700 - Tri-Ed Distribution ADR112 USER MANUAL - Ontrak Control Systems Fiches d`évaluation TPE mode d`emploi Copyright © All rights reserved.
Failed to retrieve file