Contents
1. mim mt So Voltage charging station can be SaS set can be set Tp O ea om cpp LOAD ON A A Temperature display around the 0 0 PY OFF Undervoltage protection voltage y probe Undervoltage recovery voltage can be set 2 Function keys Set parameters Set parameters Manual switch load gt Toggle key plus Minus D Long press and hold this button for 5 seconds to restore the factory settings x error or system failure click this button you can troubleshoot or eliminate x 3 Parameter settings 25 seconds keystrokes parameters are saved automaticall gt PV OFF 88 8V LOAD ON 24H LOAD OFF 88 8V LOAD ON 88 8V Set order automatic cycle Parameters setting Parameters setting This button can be manually open load or manually close the load Long press and hold this button for 5 seconds to restore the factory settings x error or system failure click this button you can troubleshoot or eliminate x 4 Common fault with processing methods Battery under voltage protection Battery normal power supply a Under voltage protection and handling screen display as shown on the right indicates the battery voltage is below the undervoltage protection voltage the controller has entered undervoltage b Retaining state disconnect the load circuit Using solar panels or charger to charge the battery when t
2. lt 25m ED weight lt 360g lt 800g lt 1000g Temperature AmV Cell C compensation Charging mode mode PWM mode Loop pressure drop lt 160mV
3. SOLARG60 SOLARS0O Solar Charging and discharging Controller User s Manual 1 Product introduction Solar LCD series a kind of intelligent multi purpose solar charge and discharge controller LCD screen display Battery reverse discharge protection Easy operation interface Battery reverse polarity protection PWM charging mode Battery under voltage protection Parameter user can reset Overload short circuit protection A key to open and close the load Automatic temperature compensation function A key to restore the factory settings Optional USB 5V charging for 500mA 2 Installation Instructions Installation Q Ready Qi installation tools and materials and cable Please matching suitable cable 2 Ensure that the current density lt 4A mm2 this will help to reduce the line pressure drop E Recommended 930A current 10mm2 60A current 20mm2 80A current 25 mm2 cable Check whether the aR installation site Comply with the relevant safety requirements avoid 1 damp dusty there is easy Inflammable explosive and corrosive gases place to install using the controller 3 Install the controller fixed to the vertical plane see Section V mounting aperture and hole spacing In order to ensure a good controller cooling conditions the controller on the bottom of each reserved 10cm space 4 As shown on the right wiring sequence load battery solarQ Battery plate is connected to the controller to be taken to ensure tha
4. he accumulator c After the battery voltage reaches the undervoltage recovery voltage the controller will restore power to the load into normal working condition 1 Overload protection and processing methods The screen shown at right load circuit current is greater than the rated current or load short circuit overload state controller has entered Reduce the load troubleshooting ress the button restore power to the load x Q oer oer System fault or Fault has ruled out 2 To charging failure handling method a Solar energy to battery charging if there is no correct configuration solar panels of power or exceed rated charging current voltage will appear charge fault the checking and debugging press the button recoverability work X Char e fault g Fault has ruled out 3 Solar panels fault and processing a 24 hours in the case of sun light the controller is not charging the solarsenergy is not connected or not connected correctly check the solar panel to the connecting cable of the controller is open troubleshooting recoverability work No solar charge ne Are chargin 5 Parameter table hiami Tee current 10mm Rated working 12V 24V Working 10 C 60 C voltage temperature Solar panels voltage eee 30 C 70 C voltage settable l l requirements a Low ee 128 mmx 188 m_ Low voltage 12 5V 25 0V Mounting hole a 98mmx178 mm ase a a D5 mm 5 mm 05 Nodoadloss load loss
5. t the load battery The polarity of the solar cell panel and controller Before use external temperature sensor probe into the left of the controller temperature probe interface probe placed in similar battery temperature Line extension must be built in devices of the external temperature probe coextensive Otherwise the controller will control parameters of the temperature compensation of the error 6 Warning In order to prevent accidents from occurring install non professionals can not be engaged in loading and unloading operations 3 LCD operating interface description 1 LCD graphic symbol description pall al Failure Discharge identit Charging logo Battery voltage Discharge fault Load state Solar panels B Charging current Discharge current Charging stops voltage Discharge stop voltage Undervoltage restore the power supply voltage Battery logo System state light control when the Percentage of battery capacity control normally open time setting lt H LOAD ON 1 H 23H Load control 1 hour 23 hours can be set Oh light control mode power supply load after dark closed after daybreak the load 24h represents a normal mode in the case of no fault the load is always in the power supply state 1h 23h light control delay mode after dark began to power the load and delay to set the time to close the load 00 0 Charging current mm g Discharge current mom oo oE int v F LOAD OFF