Home
Certificate of Compliance
Contents
1. CSA INTERNATIONAL Certificate of Compliance Certificate 2174217 Master Contract 181564 Project 2174217 Date Issued 2009 05 27 Issued to Delta Electronics Thailand Public Co Ltd 909 Soi 9 Moo 4 Pattana 1 Rd Bangpoo Industrial Estate E P Z Tambol Phraksa Amphur Muang Samut Prakan 10280 Thailand Attention Ms Kedsuda Veerasirikul The products listed below are eligible to bear the CSA Mark shown Issued by Rob Hempstock AScT Authorized by Lindsay Clark Product Group Manager Pr A PRODUCTS CLASS 5311 03 POWER SUPPLIES Component Type DIN Rail Power Supply component type Model DRP012V060W1XX where X can be 0 1 a z A Z or blank permanently connected intended for use in a controlled environment rated as follows Model DRP012V060W1XX Input 100 240 V ac 1 5 A 50 60 Hz DQD 507 Rev 2004 06 30 CSA INTERNATIONAL Certificate 2174217 Master Contract 181564 Project 2174217 Date Issued 2009 05 27 Output 12 V dc 5 0 A 60 W Notes 1 The wiring terminals are not intended for Field wiring 2 The above power supply has been evaluated in an ambient of 50 C 100 power 60 C 75 power 70 C 50 power and 80 C 10 power 3 The above power supply is certified only as a component for use in other equipment where the suitability of the combination is to be determined in the end product APPLICABLE REQUIREMENTS CAN CSA C22 2 No 0 M91 General Requi
2. evaluated in an ambient of 50 C 100 power 60 C 75 power 70 C 50 power and 80 C 10 power 3 The above power supply is certified only as a component for use in other equipment where the suitability of the combination is to be determined in the end product This report shall not be reproduced except in full without the approval of CSA International 13799 Commerce Parkway Richmond BC Canada V6V 2N9 Telephone 604 273 4581 1 800 463 6727 Fax 604 244 6600 www csc international org 2174217 Report dw DQD 507 10 Rev 2008 11 28 MASTER CONTRACT 181564 REPORT 2174217 Page No 2 PROJECT 2174217 Date Issued May 27 2009 APPLICABLE REQUIREMENTS CAN CSA C22 2 No 0 M91 General Requirements Canadian Electrical Code Part II CSA C22 2 No 0 4 04 Bonding of Electrical Equipment CSA C22 2 No 107 1 01 General Use Power Supplies MARKINGS The following markings appear on the enclosure in a permanent and visible manner i e silk screening permanent ink stamping on adhesive labels that appear on the CSA List of Accepted Adhesive Nameplates or by other permanent method 1 Submittor s name and or CSA file number 181564 2 Model designation 3 Complete electrical Input V A Hz VA or W 4 Complete electrical Output V A Hz if applicable VA or W 5 Date code or date traceable serial number 6 The CSA Monogram 7 The AC terminals are identified L N and ground 8 The DC positive an
3. product was examined and is described in the body of this report Unless specifically stated otherwise the following general definitions terminology and construction details apply Asterisk In Certified or NRTL Recognized the asterisk denotes that the CSA Monogram or UL Component Recognition or Listing Mark appears on the component being described INT Components The phrases INT indicate that the component being described may be replaced by one having the same mechanical configuration and the same or better ratings specified electrical spacings and equivalent CSA and NRTL approval status Low Voltage Limited Energy Circuit A circuit involving an alternating voltage of not more than 30 Vrms 42 4 V peak or a direct voltage of not more than 42 4 volts Dimensions dim All dimensions specified are approximations only Unless stated otherwise the least significant digit is uncertain by plus or minus one unit 2174217 Report dw DQD 507 10 Rev 2008 11 28 MASTER CONTRACT 181564 REPORT 2174217 Page No 4 PROJECT 2174217 Date Issued May 27 2009 Internal Wiring All primary Sec and grounding circuit conductors are certified Type TEW TR 64 TR 32 AWM SR PVC or AWM XL PVC rated min 90 C 300 V ac All wiring is suitably routed and secured away from sharp edges and moving parts to prevent chafing of the insulation Alternatively addition insulation is provided where the wiring passes over sharp edges and through h
4. 000V plus twice rated voltage for equipment rated at more than 250V between low voltage live parts and the enclosure if such circuits leave or enter the enclosure 2 A transformer shall withstand for one min without breakdown the application of an ac potential of 1000Y plus twice the max voltage of the winding applied between each winding and all other windings the core and the enclosure except that if the max voltage of a winding does not exceed 30V the test voltage may be reduced to 500V ac for that winding Ungrounded metallic shields are to be treated as windings when performing these dielectric strength tests Notes E As an alternative potentials 20 percent higher may be applied for one second 2 Where it is more convenient to do so the dielectric strength tests may be made by applying a direct current voltage instead of an ac voltage provided that the voltage used is 1 414 times the values specified above 3 Capacitors in the secondary circuit may be disconnected during the dielectric strength tests 4 Transformer manufacturer s agreement to perform Test No 2 will be acceptable Also this test shall be waived on certified transformers Warning The factory test s specified may present a hazard of injury to personnel and or property and should only be performed by persons knowledgeable of such hazards and under conditions designed to minimize the possibility of injury INTRODUCTION A representative sample of the subject
5. 174217 Report dw Manufacturer Thinking Electronic Industrial Co Ltd Manuf P N TTC 104 Ratings 100k ohm Remarks Secured to HS1 Alternate CSA Certified NRTL Recognized Manufacturer Uppermost Manuf P N TDC05D410 Ratings 100k ohm Remarks Secured to HS1 Diodes SD350 SD351 Ratings 30A 120V min Remarks Secured to HS2 Choke L350 Accepted Manufacturer Various Type Wire wound on core Core Ferrite Winding 1 2 four turns 3 4 four turns Copper wire 130C min Rating 90 uH min Overall Dim 19mm OD by 10 mm ID by 12 mm wide including winding Remarks Refer to Attachment 5 for construction details Heat Sink HS1 Accepted Manufacturer Various Material Aluminum Overall Dim 93 mm by 21 mm by 2mm Remarks HS1 connected to Primary Heat Sink HS2 Accepted Manufacturer Various Material Aluminum Overall Dim 35 mm by 21 mm by 7 mm Remarks HS2 connected to Secondary DQD 507 10 Rev 2008 11 28 MASTER CONTRACT 181564 REPORT 2174217 Page No 9 PROJECT 2174217 Date Issued May 27 2009 TESTS Edition 1 Project 2174217 The following tests were successfully performed at Delta Electronics Thailand under the CSA Category Program CPC and were also witnessed by a CSA representative The following clauses refer to CSA C22 2 No 107 1 01 unless other wise noted Ratings Test Clause 6 2 3 Temperature Test Clause 6 3 Dielectric S
6. Electronics Inc MV TPT8141 Open type construction Phenolic 150C 0 30 mm thick Ferrite Overall dim 30 mm by 20 mm by 19 mm Polyurethane 130C TEX E Triple insulated wire Polyester Poly Tape 130C Class B Refer to Attachment 5 for construction details Various 800V 11A Secured to Heat Sink 1 Bridging Y Capacitors CY3 CSA Certified NRTL Recognized INT Manufacturer Manuf P N Type Ratings Remarks Murato Co Ltd KX Y1 film 2200pfF 250 V ac 125C Enclosed inside a heat shrink tube rated VW 1 105C min 0 4 mm thick Opto couplers IC550 IC650 CSA Certified NRTL Recognized Manufacturer Manuf P N Ratings Alternate Manufacturer Manuf P N Ratings Alternate Manufacturer Manuf P N Ratings Alternate Manufacturer Manuf P N Ratings Alternate Manufacturer Manuf P N Ratings DQD 507 10 Rev 2008 11 28 Vishay System H or J 3000 V ac Isolation CSA Certified NRTL Recognized Vishay TCET1113G 3000 V ac Isolation CSA Certified NRTL Recognized Sharp Corp PC123Y 3000 V ac Isolation CSA Certified NRTL Recognized NEC PS2561BL1 1 3000 V ac Isolation CSA Certified NRTL Recognized Toshiba TLP781F 3000 V ac Isolation MASTER CONTRACT 181564 REPORT 2174217 Page No 8 PROJECT 2174217 Date Issued May 27 2009 n Thermistors NTC601 CSA Certified NRTL Recognized 2
7. d negative terminals are identified by the symbols and or equivalent 9 Caution Refer to installation manual or equivalent 10 The installation and operating manuals contain the following Complete instructions for mounting orientation installing and operating the equipment Environmental and maximum ambient conditions including de rating information for operation in elevated ambients Details of the AC and DC overcurrent protection and disconnects required to be provided as part of the installation 11 Caution wording CAUTION FOR USE IN A CONTROLLED ENVIRONMENT CAUTION WIRING TERMINALS ARE NOT INTENDED FOR FIELD WIRING Note Jurisdictions in Canada may require the markings in above to also be in French It is the responsibility of the Customer to provide bilingual markings where applicable in accordance with the requirements of the Provincial Regulatory Authorities It is the responsibility of the Customer to determine this requirement and have bilingual wording added to the Markings ALTERATIONS 1 The markings are as above 2174217 Report dw DQD 507 10 Rev 2008 11 28 MASTER CONTRACT 181564 REPORT 2174217 Page No 3 PROJECT 2174217 Date Issued May 27 2009 FACTORY TESTS 1 The equipment at the conclusion of manufacture and before shipment shall withstand for one min without breakdown the application of the following ac potentials a 1000V for equipment rated 250V or less and 1
8. e PWB by soldering unless otherwise stated a 2174217 Report dw Fuse F1 Manufacturer Manuf P N Type Ratings Remarks Alternate Manufacturer Manuf P N Type Ratings Remarks Alternate Manufacturer Manuf P N Type Ratings Remarks Varistor Z1 Manufacturer Manuf P N Ratings Remarks Alternate Manufacturer Manuf P N Ratings Remarks DQD 507 10 Rev 2008 11 28 CSA Certified NRTL Recognized Bell Fuse Inc SHT SHTP T T3 15AH 250Vac Enclosed inside a heat shrink tube rated VW 1 105C min 0 4 mm thick CSA Certified NRTL Recognized Littelfuse Inc 215 T T3 15AH 250Vac Enclosed inside a heat shrink tube rated VW 1 105C min 0 4 mm thick CSA Certified NRTL Recognized Schurter SPT T T3 15AH 250Vac 300Vdc Enclosed inside a heat shrink tube CSA Certified NRTL Recognized Littelfuse Inc V300LA20A 300 V ac Enclosed inside a heat shrink tube rated VW 1 105C min 0 4 mm thick CSA Certified NRTL Recognized Littelfuse Inc V320LA20A 320 V ac Enclosed inside a heat shrink tube rated VW 1 105C min 0 4 mm thick MASTER CONTRACT 181564 REPORT 2174217 PROJECT 2174217 Page No 6 Date Issued May 27 2009 Cc Bleeder Resistor RIA RIB RIC Manufacturer Various Type Carbon Ratings 750k ohm 1 4W d Line to Line Capacitor CX1 CSA Certified NRTL Reco
9. ed as shown overall 122 mm x 102 mm x 32 mm 1 5 mm thick Openings Hexagonal ventilation openings on top bottom and side of enclosure 6 5 mm diameter Mounting Spring latch Remarks Refer to Attachment 4 for details 2 Input Terminal Connector CN1 NRTL Recognized Manufacturer Dinkle Manuf P N DT 5C Rating 300Vac 10A Mounting Mounted through enclosure and secured to Connector PWB by solder 3 Output Terminal Block CN2 NRTL Recognized Manufacturer Dinkle Manuf P N DT 5C Rating 300Vac 10A Mounting Mounted through enclosure and secured to Connector PWB by solder 2174217 Report dw DQD 507 10 Rev 2008 11 28 MASTER CONTRACT 181564 REPORT 2174217 Page No 5 PROJECT 2174217 Date Issued May 27 2009 4 Insulation Barrier NRTL Recognized Manufacturer Formex Div of Illinois Tool Works Inc Formerly Fastex Div of Illinois tool Works Inc Manuf P N Formex GK 17 Flammability 94 V0 Rating Passed 3000V Dielectric Strength Test Dimensions Refer to Attachment 4 for details Remarks Provided between Chassis and PWB to meet spacings 5 PWB EOE11010159 NRTL Recognized Material As described in Introduction above Dimensions Overall 112 mm x 96 mm x 1 6 mm thickness Mounting Secured to chassis by 5 machine screws Remarks Insulation barrier Item 4 is provided between chassis and connector PWB to meet spacings The following components are mounted to th
10. gnized INT Manufacturer Acrotronics Manuf P N R 46 Type X1 film Ratings 0 22 uF 250 V ac 100C e Line Filter FL1 Accepted Manufacturer Delta Electronics Inc Manuf P N LFH TPT7038 Core Ferrite Overall dim 24 2 mm by 24 2 mm by 4 0 mm Base Chang Chun Plastics Co Ltd Type T375J Phenolic rated V 0 150C 0 45 mm thick min Bobbin Nan Ya Plastics Co Ltd Type 1403G6 PBT rated V 0 130C 0 75 mm thick min Magnetic Wire 130C min Varnish Polyester Tape Poly Tape 130C Insulation 130C Remarks Refer to Attachment 5 for construction details f Thermistors NTC1 CSA Certified NRTL Recognized INT Manufacturer Thinking Electronics Manuf P N SCK 034 Ratings 3 ohm min g Line to Ground Capacitor CY1 CY2 CSA Certified NRTL Recognized INT Manufacturer Murata Manuf P N KX KH Type Y1 or Y2 film Ratings 100pF 250 V ac 125C h Diode Bridge BD1 Manufacturer Various Rating 600V 4A i Electrolytic Capacitors C1 Manufacturer Various Rating 180uF 400V 105C 2174217 Report dw DQD 507 10 Rev 2008 11 28 MASTER CONTRACT 2174217 REPORT PROJECT 2174217 2174217 Report dw 181564 Page No 7 Date Issued May 27 2009 Transformer T1 Accepted Manufacturer Manuf P N Type Bobbin Core Pri Winding Sec Winding Varnish Tape Insulation Remarks Transistor Manufacturer Rating Remarks 1 Delta
11. oles ELV Wiring All non certified conductors and connectors in ELV sec circuits have insulation materials with a flammability rating of 94V 2 or better or are made of PVC TFE PTFE FEP or Neoprene and are routed and mechanically secured away from contacting all primary circuitry Crimp Connectors All crimp type connectors used in primary SEC and grounding circuits are certified and appropriately sized for the gauge of conductors used rated min 90 C 250 V ac Connectors All connectors used in primary and SEC circuits are certified appropriately sized for the number and gauge of conductors used Printed Wiring Boards PWB All PWBs are made of paper phenolic paper epoxy or glass epoxy min 1 6 mm thick flammability rated 94V 0 rated min 130C with a CTI of 175 min and NRTL Recognized Spacing All spacings between primary terminals and ground and between other bare live parts and ground conform to Table 6 of CSA Std 107 1 01 Spacing on printed wiring boards conform to Not Limited Uncoated Spacing as found in Table 8 Bonding All accessible metal parts liable to become energized are acceptably connected together and to the grounding means by straps and or conductors bolts screws and star washers to ensure surface coating penetration in conformance to Clause 3 4 of CSA Standard C22 2 No 0 4 DESCRIPTION Model DRP0O12V060W1XX 1 Enclosure Chassis Accepted Material Aluminum or steel Dimensions Shap
12. rements Canadian Electrical Code Part II CSA C22 2 No 0 4 04 Bonding of Electrical Equipment CSA C22 2 No 107 1 01 General Use Power Supplies DQD 507 Rev 2004 06 30 Descriptive Report and Test Results CSA INTERNATIONAL MASTER CONTRACT 181564 REPORT 2174217 PROJECT 2174217 Edition 1 May 27 2009 Project 2174217 Vancouver Issued by Rob Hempstock AScT Contents PRODUCTS Certificate of Compliance Pages 1 to 2 Supplement to Certificate of Compliance Page 1 Descriptive Report and Tests Pages 1 to 9 Attachment 1 User Manual 2 pages CSA File Only Attachment 2 Markings 2 pages Attachment 3 Schematics PWB Foil Layout and Silkscreen 4 pages Attachment 4 Construction Drawings 8 pages Attachment 5 Transformer Construction Drawings 14 pages Attachment 6 Test Data 111 pages CSA File Only Attachment 7 Raw Data 76 pages CSA File Only Attachment 8 Photographs 3 pages CLASS 5311 03 POWER SUPPLIES Component Type DIN Rail Power Supply component type Model DRP012V060W1XX where X can be 0 1 a z A Z or blank permanently connected intended for use in a controlled environment rated as follows Model Input Output Volts V ac Amps A Freq Hz Volts V dc Amps A Power W DRPO12VO060W1XX 100 240 1 5 50 60 12 5 0 60 Notes 1 The wiring terminals are not intended for Field wiring The above power supply has been
13. trength Clause 6 5 Insulating Material Clause 6 19 Abnormal Operation Output Overload Clause 6 6 1d e Short Circuit Clause 6 6 1a Forced Ventilation Blocked Vent Clause 6 6 1b Component Short Open Circuit Clause 6 6 7 Ground Impedance CSA 0 4 Refer to Attachments 6 amp 7 for test details 2174217 Report dw DQD 507 10 Rev 2008 11 28
Download Pdf Manuals
Related Search
Related Contents
Manuel d`utilisation 7 - EG Ferramentas African Monitoring of the Environment for Sustainable Quantum 600 Owner`s Manual - HME Mobility & Accessibility 消 防 予 第 102 号 平成 27 年3月 18 日 各都道府県 USB Transfer www.lindy.co USB Transfer & KM Sharing Cable www Trane BAS-SVP10A-EN Thermostat User Manual Mad Catz Magazine Card Game User's Manual Avis Technique non valide Copyright © All rights reserved.