1. onlinecomponents com THE ONLINE DISTRIBUTOR OF ELECTRONIC COMPONENTS ILB ETH 24 DI16 DIO16 2TX Possible Reasons DDI NF TASK CREAT ERR 0x0001 Error when starting a task DDI NF LISTENER ERR 0x0002 Listener task error DDI NF RECEIVER ERR 0x0003 Receiver task error DDI NF ACCEPT ERR 0x0004 Accept function error DDI NF ECHO SERVER ERR 0x0005 Echo server task error DDI NF HOST CONTROLLER ERR 0x0006 Host controller task error DDI NF DTI TIMEOUT 0x0007 DTI timeout occurred DDI NF HOST TIMEOUT 0x0008 Host timeout occurred DDI NF USER TEST 0x0009 NetFail set by user DDI NF CONN ABORT 0x000A Connection aborted DDI NF INIT ERR 0x000B Initialization error DDI NF DTI WATCHDOG 0x000C Process data watchdog triggered DDI_NF_MBUS_TIMEOUT 0x000D Modbus timeout occurred PHOENIX CONTACT 24 13 Modbus TCP Protocol The module supports a Modbus TCP server with the following features 13 1 Modbus Connections The module supports up to eight connections at the same time In this way a connection can quickly be re established This implies that the client can successfully restore an interrupted Modbus connection 13 2 Modbus Interface The Modbus interface according to the standard port 502 supports Modbus communication via the ILB ETH 24 DI16 DIO16 2TX module 13 3 Modbus Conformity Classes The ILB ETH 24 DI16 DIO16 2TX module supports Modbus conformi
2. 10 2 Structure of the Web Pages The module web pages are divided into two parts with the navigation tree and the relevant submenus on the left hand side and the corresponding information displayed on the right hand side PHOENIX CONTACT 17 THE ONLINE DISTRIBUTOR OF ELECTRONIC COMPONENTS ILB ETH 24 DI16 DIO16 2TX ILB ETH 24 DI16 DIO 16 2TX General Instructions Ly Information Device Information Device Information Technical Data Hardware Installation Local Diagnostics gt Device Configuration IP Configuration SNMP Configuration Software Update Change Password Watchdog Hardware Port Configuration Block IO Process Data Monitoring Process Data Watchdog Remote Diagnostics Process Data Event Table 6155A004 Figure 9 Structure of the web pages 10 3 IP Configuration Menu Figure 10 shows the set IP parameters and addressing mechanism To change the IP parameters via the WBM BootP Request must be set to Disable or the module s BootP requests must not be answered no BootP server must be activated in the network IP Configuration IP Address fi 92 168 2 81 Subnet Mask 255 255 255 0 Default Gateway 0 0 0 0 Please enter IP Address Subnet Mask and Gateway Address in dotted decimal notation e g 172 16 16 230 The changes will fake effect after the reboot of the LB ETH 24 DIT6 DIOTE 2TX Enter Password Reboot BootP Requests f Enable C Disable B
3. 24 V communicatons power present OFF 24 V communications power not present UA ee C IN OUT Each Connector Short circuit or overload of the outputs Yellow Input output active Tet Netw Input output not active D IN Each Connector Short circuit or overload of one of the sensor supplies No sensor supply error von ow Input active OFF Input not active i If the error LED E of a group of eight outputs e g connector 3 4 or connector 5 6 lights up this indicates that a short circuit or overload is present at one or more of the outputs in this group 7046_en_02 PHOENIX CONTACT 11 onlinecomponents com THE ONLINE DISTRIBUTOR OF ELECTRONIC COMPONENTS ILB ETH 24 DI16 DIO16 2TX 7 Connecting Ethernet the Supply and Actuators and Sensors 7 1 By default upon delivery the Ethernet connections have been set to auto negotiation with auto crossover Connecting Ethernet If a port is set to fixed transmission parameters speed duplex mode auto crossover is deactivated In this case the port acts like a switch port MDI X The pin assignment is specified accordingly The module must be connected to termination devices using a 1 1 cable and to other configuration devices using a cross over cable Connect Ethernet to the module using an 8 pos RJ45 connector For the pin assignment of the RJ45 female connector please refer to the following table RD re
4. ASN1 descriptions of this product It can be downloaded at www download phoenixcontact com The password for read access is public and cannot be modified By default upon delivery the password for read write access is private and can be modified at any time The same password is used for the web interface see page 18 7046_en_02 PHOENIX CONTACT 21 THE ONLINE DISTRIBUTOR OF ELECTRONIC COMPONENTS ILB ETH 24 DI16 DIO16 2TX 12 Monitoring Functions Monitoring functions with different features are available for monitoring Ethernet communication Process data watchdog process data monitoring Connection monitoring for Modbus see Modbus Connection Timeout on page 30 and DTI see Connection and Error Monitoring on page 27 There are monitoring functions according to the features functions that need to be monitored According to the application requirements the appropriate monitoring function can be activated By default upon delivery process data watchdog is activated Monitoring Mechanism Monitoring the Client the the Ethernet Process Data Application Individual Connection Exchange Channels Process data watchdog process X X X data monitoring Connection monitoring for Modbus X X X and DTI In the event of an error the system reacts with a fault response The user determines the required fault response mode 12 1 Setting the Required Fault Response Mode The required fault response
5. PLUG RJ45 GR 2 2744856 2 Green RJ45 connector set for crossed cable FL PLUG RJ45 GN 2 2744571 2 Double sheathed Ethernet cable FL CAT5 HEAVY 2744814 1 Flexible Ethernet cable FL CAT5 FLEX 2744830 1 Assembly tool for RJ45 connector FL CRIMPTOOL 2744869 1 Matching dust protection covers and safety systems for RJ45 connections can be found in the product range of Reichle amp De Massari Switzerland Accessories Software Description Type Order No Pcs Pkt Factory Manager network management software FL SWT 2831044 1 You can use Factory Manager for Ethernet network diagnostics as well as for firmware updates of the ILB ETH 24 DI16 DIO16 2TX module However it is not required for module startup INTERBUS OPC server IBS OPC SERVER 2729127 1 CD ROM with German and English product version 2 1x and online documentation Additional language versions are available on request Accessories Connectors as Replacement Item Description Type Order No Pcs Pkt Connector for the supply color print ILB SCN 12 PWR IN CP 2863164 5 Connector for digital 4 channel or 16 channel Inline input terminals with color IB IL SCN 12 ICP 2727611 10 print Accessories Other Description Type Order No Pcs Pkt Recommended end clamp placed both to the right and left of the module to CLIPFIX 35 5 3022276 50 secure it on the DIN rail Documentation Description Type Order No Pcs Pkt Mounting and Removing Inline Block IO Modules application no
6. ccccseccececeeeseeeseeeeeeeceecceescececeeesensces MQ MMe csseceecceesceescesscessonesceesseeess 29 EE Ge EEE RE VEE EEE 29 15 2 I O Diagnostic Register cccccccccseeeeecceseeeecseseceeccsees Micon egal ccccsscccesccssceccscseeeeseescaseeeescuseeeeesoueeeeses 29 15 3 NetFail Reason EEE AMMAN KE ERE 29 16 Special Register cccccccececeeeceececeee scenes cee e es MEAD ccc cceccceceseseeceeesceeesonsseenesaeeeceeeeseenesaees 30 16 1 Modbus Connection Timeout c ccccccccccsssseduccsbeccessecsceeccsuecececeueececsueeeessseeecesageeeessuueeeeessaeeeessenseeesaas 30 16 2 Process Data Watchdog Timeout rrrrrnnrrvnnnnrevnnnrrrrnerernnnrerrnnrrennnrernnnsrennnnnennnneennnnennnnsernnnsennneennnneennnnsen 30 16 3 Fault Response Mode ccccceccccseecesececanecenenseueeceuceceuceceueeseueeeueessauessueesauuessaeessueeseueessaeessusessueessueesanenas 30 16 4 Command Register cccccccc ees QW Reece eeccecccsenecccceeceescassueesceseeecescneeeecueesesscuseeeecassaeeescseeessscesesesees 30 7046_en_02 PHOENIX CONTACT 3 THE ONLINE DISTRIBUTOR OF ELECTRONIC COMPONENTS ILB ETH 24 DI16 DIO16 2TX 2 Ordering Data Product Description Type Order No Pcs Pkt Inline Block IO module for Ethernet ILB ETH 24 DI16 DIO16 2TX 2832962 1 with 16 digital inputs and 16 digital inputs or outputs Accessories Ethernet Description Type Order No Pcs Pkt Gray RJ45 connector set for linear cable FL
7. mode can be set via web based management by writing to Modbus register 2002 using DTI byte address 4004 or via the ETH_SetNet FailMode function The following fault response modes are available Fault Response Mode Reset fault mode The C outputs are set to 0 default Standard fault mode 0 All outputs are set to 0 Hold last state mode 2 All outputs retain their last value Ev As this module does not have analog outputs the behavior in reset fault mode and standard fault mode is identical 7046 en 02 PHOENIX CONTACT 22 onlinecomponents com THE ONLINE DISTRIBUTOR OF ELECTRONIC COMPONENTS ILB ETH 24 DI16 DIO16 2TX 12 2 Process Data Watchdog Process Data Monitoring Ev By default upon delivery the process data watchdog is activated with 500 ms timeout Process Data Monitoring f Reset Fault Mode default Standard Fault Mode C Hold Last State Mode Process Data Watchdog for Timeout su ine Fault Response Mode The time is indicated in milliseconds and ranges from 200 ms fo 65 000 ms A value of 0 ms disables fhe Process OUT Data Monitoring Enter password Apply Network Failure Status No network failure NF occurred Confirm Enter password Figure 13 Configuring process data monitoring in the WEB Process Data Watchdog Function A process data watchdog is integrated into the ILB ETH 24 DI16 DIO16 2TX module to avoid uncontro
8. rrrnnnnnnnnnnnnnnnnenrnnnnnrnnnnnnrrnvrnnnrennnnnrrennnnsnennnnnssnennnnnsenennnseennnnnsseennnnsnsen 17 10 2 Structure of the Web Pages rrrrrrarnrnnrnnnnovnrnnnnrnvrnnnnnrnrnnnnrnnnnnnnrnnrnnnesrnnnnnnsnnnnnsnrrnnnnnnsnnnnnnannnsnnnnnnessnnnnnnsnnn 17 10 3 IP COmfiQguratioMMGQu cccccccseceeccssseeeesceseeecceceeeescaseneescceseeessosaaeescaseeeeescoseeesscasaseeeescuseeesssceeeeeseas 18 VOB PTE rs duawtdaiel Scbseenorundaateuenial tt 18 10 5 Firmware Update via WBM rrrrnnnonnnrrrnnrrnnnrrvnnnrnnnnrnnnrrnnnrnrnnrnnnnennnnrnnnsennanennanennneennnnennanennanenennnennnsnnnssnnnnene 19 10 6 Procgss Mata ACCESS via ML sicaciedenicinatvodaatteadaiaadacnciasaieeoteususdiikdiaa uisieadiabaetesean taal Mens veeaeniesshuwexsdanasedtaaveals 19 107 MEST 20 SP 21 va ME ed re eRe re eR ee ee ee ee ene ee eee 21 VU VS 21 12 Monitoring FUNGIONS marsk E EE DEEE EAEE 22 12 1 Setting the Required Fault Response Mode rrrannrnnnnnrnnannonrnnnenrnnnevnnnnrnrrnnrrnnnnrnnnannennnnsennnasennnnsennnnsennnnnsene 22 12 2 Process Data Watchdog Process Data Monitoring rrrrrnrrnrvvrnnnrevnrnnnrrrrnnnnnernrnnerrennnnerrennnnsrennnnnsrrennnnnsnnen 23 12 3 Fault Response Acknowledgement rrrnnnnvrnnnnnvnnnnevnnnnnennnnnennnnnvnnnnnennnnnsrnnnnennnnnennnnnnennnnsrnnnnnennnnssnnnnnennnnnsen 24 7046 en 02 PHOENIX CONTACT 2 onlinecomponents com THE ONLINE DISTRIBUTOR OF ELECTRONIC COMPONENTS ILB ETH 24 DI16 DIO16 2TX 13 MONS TC
9. 1500 V rms 50 Hz to 60 Hz 1 min 5g load 2 5 hours in each space direction 25g load for 11 ms half sinusoidal wave 3 shocks in each space direction and orientation 0 78g load 2 5 hours in each space direction Criterion B 4 kV contact discharge 8 kV air discharge Criterion A Field strength 10 V m Criterion B Remote bus 2 kV Power supply 2 kV I O cables 2 kV Criterion A All interfaces 1 kV Criterion B DC supply lines 0 5 kV 1 0 kV symmetrical asymmetrical Signal lines 1 kV 1 kV symmetrical asymmetrical Criterion A Test voltage 10 V Class A 2 x Ethernet twisted pair according to 802 3u via RJ45 connector shielding directly connected to functional earth ground 24 V Module Supply Communications Power Sensor and Actuator Supply UL Us and Ua Nominal value Tolerance Ripple Permissible range Current consumption at UL Current consumption at Us and Us Current consumption at Ua and Uno Safety equipment for communications power Safety equipment for sensor supply Safety equipment for actuator supply Connection 7046_en_02 24 V DC 15 20 according to EN 61131 2 5 according to EN 61131 2 19 2 V DC to 30 0 V DC 70 mA 2x2A 2x4A Surge protection and protection against polarity reversal Surge overload and short circuit protection Surge protection Via power connectors PHOENIX CONTACT 6 Digital Outputs Number Connection method for actuators Nominal output vol
10. 2103 UL 508 25 C to 60 C 25 C to 85 C 10 to 95 according to EN 61131 2 80 kPa to 108 kPa up to 2000 m above sea level 66 kPa to 108 kPa up to 3500 m above sea level IP20 Class 3 according to VDE 0106 IEC 60536 According to DIN VDE 0110 IEC 60664 IEC 60664A DIN VDE 0160 EN 50178 IEC 62103 Plastic PVC free PBT self extinguishing VO 2 condensation not permitted during operation PHOENIX CONTACT 95 Electrical Isolation Isolation of the Voltage Areas Test Distance I O Logic I O functional earth ground Logic functional earth ground Ethernet interface signals logic Mechanical Requirements Vibration test sinusoidal vibrations according to EN 60068 2 6 IEC 60068 2 6 Shock test according to EN 60068 2 27 IEC 60068 2 27 Broadband noise according to EN 60068 2 64 IEC 60068 2 64 Conformance With EMC Directive 89 336 EEC Noise Immunity Test According to EN 61000 6 2 Electrostatic discharge ESD EN 61000 4 2 IEC 61000 4 2 Electromagnetic fields EN 61000 4 3 IEC 61000 4 3 Fast transients burst EN 61000 4 4 IEC 61000 4 4 Surge voltage EN 61000 4 5 IEC 61000 4 5 Conducted interference EN 61000 4 6 IEC 61000 4 6 Noise Emission Test According to EN 61000 6 4 Noise emission of housing EN 55011 Interface Ethernet interface THE ONLINE DISTRIBUTOR OF ELECTRONIC COMPONENTS ILB ETH 24 DI16 DIO16 2TX Test Voltage 500 V AC 50 Hz 1 min 500 V AC 50 Hz 1 min 500 V AC 50 Hz 1 min
11. 2125 118 22 12 25 15 22142 25 1523 Terminai pi ONDE 23 13 28 1 23 13 20 frs lza 13 28 lis 23 13 Sausindieator Sot ww 909 800 iB penupppupppyuppe Nr 7046 en 02 PHOENIX CONTACT 28 15 Diagnostic Register 15 1 Status Register Address Modbus Register 4 DDI Word starting with 08 Via the Ethernet host controller e g PLC the user can read current diagnostic information from the network interface status word without using a configuration software Only those two least significant bits bit 0 and bit 1 have a function Bit 2 up to bit 15 are reserved Bit 0 0 An error occurred e g a bit in the diagnostic register is set Bit 0 1 No error Bit 1 0 No NetFail Bit 1 1 NetFail is present This results in the following values for the status word Register Contents 0000 ex An error occurred e g a bit in the diagnostic register is set 000 The 0002 hex A NetFail occurred 23 The errors are indicated until they are acknowledged 15 2 Address Modbus Register 5 DDI Word starting with 04hex The I O diagnostic register is used to indicate detailed information on module diagnostics The DIA LED is red if a bit is set here I O Diagnostic Register 7046_en_02 onlinecomponents com THE ONLINE DISTRIBUTOR OF ELECTRONIC COMPONENTS ILB ETH 24 DI16 DIO16 2TX s a a 2 ijo 1 Short circuit output overload 1 Shor
12. 4 13 12414 24 14 24 fk 24 1 24 A 24 eT Terminai pont GND 28 1 23 113 2 te 2313 ze fte las 13 28 lie 23 15 Status indicator ep upper uppepupppupp p Assignment of the Terminal Points to the IN Process Data Word Slots 3 to 6 Word bit view Word Word gt Be E fr Mi 10 fe Ja P A e 18 f2 0 Module 3707 Freminalpont U 25 15 22 12 25 15 22 12 25 15 22 12 25 15 22 12 Terini po OND 28 1 23 13 fas ts aw ze 12 23 13 120 15 23 13 Status Indicator 01 Assignment of the Terminal Points to the IN Process Data Word Slots 7 to 10 Word bit view 1 Module Slot ae E E Teminat Op 28 1522 112 25 115 22 12 125 15 22 12 25 1522 Termin pi GND 23 13 28 ts 23 13 ze fte 23 13 128 hs 23 13 Sausindieator Sot ww 909 800 ep pe PE Pe Pies 2 7046_en_02 PHOENIX CONTACT 26 THE ONLINE DISTRIBUTOR OF ELECTRONIC COMPONENTS ILB ETH 24 DI16 DIO16 2TX 14 Device Driver Interface DDI The ILB ETH 24 DI16 DIO16 2TX module supports access via the Device Driver Interface DDI A driver for Windows NT and Windows 2000 can be found at www download phoenixcontact com It is called Ethernet Driver 2 0 exe Phoenix Contact informs you about drivers for other operating systems on request Using this interface requires the appropriate driver to be installed on the host For a detailed description of the services please refer to the Driver Reference Manual
13. 6 en 02 Total power dissipation of the module Current from the sensor supply at slots 3 to 6 Current from the sensor supply at slots 7 to 10 Continuous index Number of set outputs n 1 to 16 Load current of output i Continuous index Number of set inputs n 1 to 32 A 8 tot 2 0 Mo 6992B012 A l tot 6992B013 T PHOENIX CONTACT 8 4 Internal Circuit Diagram LNK1 2 ACT1 2 BOOT nF RDY DIA Z Z al 3 7 sf A1 U A r7 DIO1 8 DIO9 16 a ry 2TX ETH Figure 2 Internal wiring of the terminal points Ke LED Microprocessor Switch Transmitter fig e Le bel 5 Relevant Notes Shielding The shielding ground of the connected twisted pair cables is electrically connected with FE When connecting network segments avoid ground loops potential transfers and equipotential bonding currents using the braided shield 7046_en_02 onlinecomponents com THE ONLINE DISTRIBUTOR OF ELECTRONIC COMPONENTS ILB ETH 24 DI16 DIO16 2TX 7046B004 Power supply unit with electrical isolation Optocoupler Short circuit proof output Short circuit proof sensor supply Electrostatic discharge The module contains components that can be damaged or destroyed by electrostatic discharge When handling this module observe the necessary safety precautions against electrostatic discharge ESD in accordance with EN 61340 5 1 and EN 61340 5 2 PHOENIX CONTACT 9 THE ONLINE D
14. ILB ETH 24 DI16 DIO16 2TX THE ONLINE DISTRIBUTOR OF ELECTRONIC COMPONENTS Inline Block IO Module 1 for Ethernet With 16 Digital Inputs D and 16 Digital Inputs or Outputs pp AUTOMATIONWORX Data Sheet 7046 en 02 PHOENIX CONTACT 03 2007 1 Description The ILB ETH 24 DI16 DIO16 2TX module is designed for use within an Ethernet network It is used to acquire and output digital signals 1 1 Ethernet Features 2 x Ethernet twisted pair according to 802 3u with auto negotiation and auto crossover connected via an integrated managed 3 port switch 2 external ports 1 internal port Transmission rates of 10 Mbps and 100 Mbps IP parameter setting via BootP Software interface Modbus TCP or DDI Device Driver Interface Management via WEB and SNMP OPC server 2 14 support 1 2 1 3 Input Features Connections for 16 digital sensors Connection of sensors in 2 and 3 wire technology Maximum permissible load current per sensor 125 mA Maximum permissible load current from the sensor supply 2 0A Combined Input and Output Features Connections for 16 digital sensors actuators Each single channel can only be used as an input or as an output Connection of sensors in 2 and 3 wire technology Maximum permissible load current per sensor 125 mA Maximum permissible load current from the sensor supply 2 0A Connection of actuators in 2 wire technology Nominal current per output 0 5 A Total current of all output
15. IN DIO 1 0 O3hex 16 bit IN DI Disabled Disabled Trine back output register Obes Owe Stetusregser Dis Onex OBnex _WOdiagnosticregister Ds ed Whee ODnex NetFalreason Ds For OPC compatibility 40004ec 40014ec Process data watchdog timeout Process data watchdog timeout A004 dec 40054ec Fault response mode Fault response mode NetFail test EE value as register OChex 40124ec 4013 dec Te register Command register MG en PHOENIX CONTACT 27 THE ONLINE DISTRIBUTOR OF ELECTRONIC COMPONENTS ILB ETH 24 DI16 DIO16 2TX 14 5 Process Data Assignment DDI Assignment of the Terminal Points to the OUT Process Data Word Slots 3 to 6 Byte bit view Word Word Byte Bt ee dae ees ee da 0 Module 107 Terminal pot gran 24 4 at ci ea sa 24 1 24 ta 24 1 24 a 2410 Terminai pone GND 28 1 23 113 28 te 23 113 20 fts 23 13 28 lie 23 15 Status indicator Assignment of the Terminal Points to the IN Process Data Word Slots 3 to 6 Byte bit view Word Word fa Bye Bk 7 Je 15 Ja fa fe 1 Jo M le 18 2 0 Module 3707 Freminalpont U 28 115122 11212515 22112 25 1 22 12 125 1522 12 Teminat pone OND 28 1 23 13 fas 1 aw 125 18 23 13 120 15 23 13 Status indicator 3001 Assignment of the Terminal Points to the IN Process Data Word Slots 7 to 10 Byte bit view 2 a 3 Module Slot a Temno Ua 28 15122 11
16. ISTRIBUTOR OF ELECTRONIC COMPONENTS ILB ETH 24 DI16 DIO16 2TX Oo Cc cC O V pas Oo Q O Cc O O X Cc O ke A O oO N bi O om 3 14 C O D n O lt Oo am C Oo Q O O O Oo oO Q Se 14 Local Diagnostic and Status Indicators 6 7046A002 I eee a Ee N 1099 0 03 2TX module Diagnostic and status indicators of the ILB ETH 24 DI16 DIO16 Figure 3 PHOENIX CONTACT 10 7046 en 02 THE ONLINE DISTRIBUTOR OF ELECTRONIC COMPONENTS ILB ETH 24 DI16 DIO16 2TX Designation color weaning O O OOOO A Module and Ethernet BOOT Boot loader inactive firmware successfully started Flashing Waiting for BootP reply ON oo Start firmware OFF Firmware not active em Firmware ready to operate Connection to a process data client established OFF No network error error occurred during the firmware update Hardware watchdog triggered Flashing together with DIA There is no module diagnostics ON Therei is module diagnostics A bit is set in the diagnostic register i Flashing Firmware error Flashing Hardware watchdog triggered together with Gage KE ACT1 2 Yellow No transmission or reception of Ethernet telegrams at port 1 2 pen Transmission or reception of Ethernet telegrams at port 1 2 B PWR US1 2 ION Sensor supply 1 2 present Me Sensor upp 1 not present ON 7
17. P PO vere dee 25 13 14 Modbus COMMGCH OMS RR 25 13 2 MENE 25 13 3 Modbus Conformity Classes rrrrrannnrnnnrnnnrrnrnnnnnrnrrnnnrnnnnnnnrrnrnnnnrrnnnnnersnnnnnsnsnnnnnsnrennnnnsennnnnsssssnnnnnsneennnnsnsen 25 13 4 Modbus Function Codes rrannnnrrnnnnnrnnnnnnnrrnnvnnnnrennrnnsrrrnnnnsrevnrnnsrsennnnnsnnnnnnsnsennnnnsrennrnnsneennnssnssnennnnnsseennnnsnsen 25 Tor Moapi ET 0 gt ERE EEE EE E A A 25 13 6 Process Data Assignment Modbus rrrrrrrvrrnnnrrvrrnnnrrenrnnnnrrvrnnsnrrnvnnnrrnnnnsrrrnnnnsnennnnnserennnnsnennnnnnssrennnnnssenn 26 14 Device Driver Interface DDI rrranrnnnnrnanrrnanernnnnnnnrnnnnnnannnnanennnnnnanennanennnarnanenannnnanennuennnsnnnnne 27 14 1 Connection and Error Monitoring cccccceecceecneeeeeeseeeeeeecaeeeeeeeeaeeeeeeseeeeeeeseaeeeeeesaeseeesseaeeeeeseseaeeeeeeseneeeeeaas 27 14 2 Services for Process Data Monitoring rrrrrrnnnnrvnrrnnnrrrrnnnnnrnrnnnnrenrnnnnrrnnnnnnnennnnnrennnnnrerennnnsennrnnnnsneennnnsnsen 27 14 3 Services for Ethernet Connection Management rrnnnnnnnnnnnnnnrnnnnnennnnnnnrrnnnnnrrrnannnnenrnnnntennnnnnesnnnnnsnrennnnnsnnn 27 14 4 Structure of the DT Area cc ccccccccsseceeccesseeecceeeeeeceessceeeceusececseeseeesseseccaneasseebeseaseeeseuseugseesssuseeesseseeeeeas 27 14 5 Process Data Assignment DDI ccccccccseseeeecceseeeeesceeeeessceseseccees er MMB cccccssesecccsseeeesseceseeeeesceeeeeses 28 15 Diagnostic Register c
18. RMINAL and ILB BUS PD IN This area is used by all group lt s that use input ILB BUS TERMINAL data The number of process data words depends This data area contains information about the module vi FN l l this module Belonging to this data area PD OUT TERMINAL_TYPE This area contains the module designation i e always ILB ETH 24 DI16 DIO16 2TX This area is used by all terminals with output data The use of bits is identical with the that in PD_IN NAME Contains the user specific station names The station name can be modified via SNMP or WBM IP_ADDRESS Contains the IP address of the station GROUP_NUMBER 2 DIO and DI DIAGNOSTIC_REGISTER Contains the module status represented by all bits of the I O diagnostic register ILB_BUS Frame for the existing groups ILB_GROUP Frame for the data of an individual group GROUP TYPE Contains the terminal type Possible types are DI and DIO PD CHANNELS Number of process data channels in a group For digital modules the number of channels is equal to the number of supported bits Always 16 bits with this module 7046_en_02 PHOENIX CONTACT 20 onlinecomponents com THE ONLINE DISTRIBUTOR OF ELECTRONIC COMPONENTS ILB ETH 24 DI16 DIO16 2TX lt xml version 1 0 encoding ISO 8859 1 gt lt DOCTYPE ILB_STATION View Source for full doctype gt lt ILB_STATION gt lt ILB BUS TERMINAL gt lt TERMINAL TYPE gt ILB ETH 24 DI16 DIO 16 2T
19. Supply and Actuators and Sensors rnrrnrrnnrennnrnnnennnrnnernnernnnrnnnennne 12 7 1 Connecting Ethernet cccccsssccesceseeeecsceseeeccssseceesccesescescess Am Qccccccccsecccesasenecsscacsseneesccseeeessceseessees 12 7 2 Connecting the Supply Actuators and Sensors rrrrrranrrrnnrnnerranvnnnnrrnnnnnnnrrnrnnsrrennrnnsrrennnnnrrrnnnnnenenrennnnnsnee 13 7 3 Terminal Point Assignment of the Power Connectors Connectors 1 and 2 in Figure 6 ccccesseeeeees 13 7 4 Terminal Point Assignment of the Input and Output Connectors Connectors 3 and 6 in Figure 6 on page 13 rrrnrrnnnrnnnnrnnnrnnnnnnnnennnnnrennrnnrrennnnerrennnnnerrennnsnrsnnnnnsrennnnnnssen 14 7 5 Terminal Point Assignment of the Input Connectors Connectors 7 to 10 in Figure 6 on page 13 14 Connection EX AION S avse tend iMacs Wher oeccnsiectoanaadsecebseucdsuasvetesedadceustabsccnssWicbsenceseneeeat 15 260 er Ch ie ee eee ee eee 16 9 1 Default upon Delivery Default Settings cece ccccccececcceesecececeeceecceeseeecseuseecsseuseeeseeeeeecsuaseseesegseeesssaeeees 16 EEE GOGL Ga EEE 16 9 3 Sending BootP Requests rrrrrrnnrrrnrrnnnrnnnnnnnnrnrnnnnnrrnrnnnnrnnnnnnrrnnnnnsrrnnnnnnsnnnnnsnnsnnnnsessrnnnnnsrnnnnnnsnnnnussrnnnnnnee 17 9 4 Reconfiguration Button 4 s rrrrvvnnrrvrrrnnnnrvvrnnnnnvrvnnnnnrrrvnnnnrnnnnnnnrnnnnnnnnennnnnnnnnnnnnnsnnnnnnnnnsnnnnnnnnnsnnnnnnnennnnnnnee 17 10 1 Calling Web Based Management
20. X lt TERMINAL TYPE gt lt NAME gt Inline Block IO lt NAME gt S Station data lt IP ADDRESS gt 172 16 16 1 lt IP ADDRESS gt lt GROUP NUMBER gt 2 lt GROUP NUMBER gt lt DIAGNOSTIC_REGISTER gt O lt DIAGNOSTIC_REGISTER gt iill 1 0 diagnostic register lt ILB_BUS_TERMINAL gt lt ILB_BUS gt lt ILB_GROUP number 1 gt lt GROUP_TYPE gt DIO lt GROUP_TYPE gt lt PD_CHANNELS gt 16 lt PD_CHANNELS gt lt PD WORDS gt 1 lt PD WORDS gt lt Io1 I04 IN gt lt PD_IN word 1 gt 0 lt PD_IN gt ill DIO input data lt l IOl I04 OUT gt lt PD OUT word 1 gt 0 lt PD_OUT gt illl DIO output data lt ILB_GROUP gt lt JLB_GROUP number 2 gt lt GROUP_TYPE gt DI lt GROUP_TYPE gt lt PD_CHANNELS gt 16 lt PD_CHANNELS gt lt PD WORDS gt 1 lt PD WORDS gt lt l 4 IN gt lt PD IN word 1 gt 0 lt PD_IN gt ef DI input data lt ILB_GROUP gt lt ILB_BUS gt lt ILB_STATION gt Figure 12 Screen for XML data 11 SNMP 11 2 Traps The ILB ETH 24 DI16 DIO16 2TX module supports the following traps Cold Start is transmitted with every restart of the 11 1 MIBs module in version v1 and V2c Authentication wrong password for SNMP access The ILB ETH 24 DI16 DIO16 2TX module supports SNMP v1 and v2c The module supports the following MIBs MIB Il defined by RFC 1213 ILB ETH 24 MIB in version 1 0 For the object descriptions please refer to the
21. ble and a reply with values for TFTP Server IP Address and Downloadable File Name is received the entries done in WMB are overwritten with these specifications After restart the values accepted are displayed in WBM In the event of an error during flash programming e g voltage interrupt the device can only be restarted by repeating the update The device indicates this by means of the BOOT and NF LED combination The devices starts the update automatically after a restart Access to WBM is no longer possible IR An application note for TFTP download using Factory Manager AH EN TFTP FIRMWARE UPDATE can be found at www download phoenixcontact com 10 6 Process Data Access via XML The web server of the ILB ETH 24 DI16 DIO16 2TX offers the possibility to access the process data via a web page in XML format You can access the web pages via a standard web browser For calling the XML pages with the process data enter the address in the following format in the address line of the browser http lt IP address gt processdata xml PHOENIX CONTACT 19 onlinecomponents com THE ONLINE DISTRIBUTOR OF ELECTRONIC COMPONENTS ILB ETH 24 DI16 DIO16 2TX 10 7 XML File Structure The XML file contains different data areas PD WORDS Number of process data words in a group Always ILB STATION one process data word with this module Frame for the entire XML file The obligatory elements of this frame are ILB BUS TE
22. ceive data RD receive data For further information on Ethernet cabling please refer to www iaona eu com Pin D 6 __ D vansmitdata SSCS e Rema 7046_en_02 NG Eo DER Syke A SYA g 60 Dog g De D 5p Figure 5 For further information on t 7046A006 8 pos RJ45 female connectors he reconfiguration button please refer to page 16 PHOENIX CONTACT 12 onlinecomponents com THE ONLINE DISTRIBUTOR OF ELECTRONIC COMPONENTS ILB ETH 24 DI16 DIO16 2TX 7 2 Connecting the Supply Actuators and Sensors gt K AN MW A N EN N NA ESN N Va SN A SY Su ess f I Sua VE Cay VS SJ DN CRs SY JA CYA S REL S NA Sa Ne A UDI 7046A003 Figure 6 Terminal point assignment of the Inline connectors 7 3 Terminal Point Assignment of the Power Connectors Connectors 1 and 2 in Figure 6 Terminal Point Assignment Terminal Point Assignment 24V sensor supply Us 24 24Vsensorsupplylsg a2 24V communications power 22 24V communications power U K E 28 em 14 E CEC a5 24V communications powerU 25 24V communications power UL 6 C E E Connector 2 PWR 2 14 Actuator suppy Um Actuator supply Ue O O a2 24V communications power 22 24V communications powerUL m C 28 em H 24
23. cknowledgement 0004hex Diagnostic message acknowledgement I O error PHOENIX CONTACT GmbH amp Co KG 32823 Blomberg Germany 30 Phone 49 0 5235 3 00 Fax 49 0 5235 3 4 12 00 www phoenixcontact com
24. e click on Apply and Reboot for the update to take effect immediately Check execution of the update After Apply and Reboot the browser automatically updates the web pages and displays the result in the TFTP Update Status field After successful update and initial firmware start Firmware Update was successfully executed is displayed In the event of an error during downloading the corresponding error message is indicated The device indicates this error by means of the BOOT RDY and NF LED combination A restart repeats the downloading process Activating Disable in the Software Update on Next Reboot field allows for update abortion and starting the previous firmware again software Update TFTP Server IP Address TETRA 1192 168 2 10 Downloadable File Name filb eth dil 6 dio16 2tx v Software Update on Net Di Reboot Enable Disable TFTP Update Status Firmware Update was successfully executed ifthe software update status is set fo enable fhe ILB ETH 24 DITE DIOT6 2TX will fry fo load new software within fhe next reboot Press fhe apply button fo change fhe software uodate status The settings will fake effect after fhe next reboot of the ILB ETH 24 DITE DIOTE 2T X Enter password Apply Apply and Reboot Figure 11 Software Update menu 7046 en 02 onlinecomponents com THE ONLINE DISTRIBUTOR OF ELECTRONIC COMPONENTS ILB ETH 24 DI16 DIO16 2TX If BootP is set to Ena
25. efore disabling automatic BootP setting be sure fo record the current IP address You will need he current IP address if you want fo re enable BootP setting of fhe P address If you forget the IP address the only way IS fo delate fhe whole configuration over the Reconf Bufton Enter Password Apply Figure 10 IP Configuration menu 10 4 Password Protection All status changes to the module are only possible after entering a password The password can be changed at any time Your unique password must be between four and twelve characters long note that the password is case sensitive By default upon delivery the password is private The password for the web is the same as for the SNMP read and write access Forgetting the password requires resetting the entire configuration using the reconfiguration button in order to be able to access the module again PHOENIX CONTACT 18 7046_en_02 10 5 Firmware Update via WBM The following steps must be carried out when executing a firmware update via WBM In WBM click on Device Configuration and then Software Update Enter the IP address of the TFTP server in the TFTP Server IP Address field Then enter the file name of the firmware and the path name if necessary in the Downloadable File Name field In the Software Update on Next Reboot field click on Enable Enter your password and click Apply to execute a reboot at a later tim
26. f 24 V communications power U 25 24V communications power ep 26 en The terminal points can have a total current of The supply points have the same ground 8 A per terminal point The maximum current potential All ground supplies on a module are carrying capacity of 8 A must not be exceeded electrically connected with one another If the total output current in your application is The communications power is also electrically gt gt 8 A supply the module via a minimum of two connected via all contacts In this way it can terminal points connected in parallel supply all potentials with just one supply without the need for additional terminals see Connection Example on page 15 7046_en_02 PHOENIX CONTACT 13 THE ONLINE DISTRIBUTOR OF ELECTRONIC COMPONENTS ILB ETH 24 DI16 DIO16 2TX 7 4 Terminal Point Assignment of the Input and Output Connectors Connectors 3 and 6 in Figure 6 on page 13 Terminal Point Connector 3 Connector 4 Connector 5 Connector 6 101 102 103 104 Signal input IN and output OUT 12 22 1222 11222 12 22 Sensor voltage U for 2 and 3 wire termination 1 3 23 14 3 2 3 14 3 2 3 1 3 2 3 Ground contact GND for 3 wire termination 4424 4424 14 24 44 24 Signal nput IN and output OUT 1 5 25 15 25 15 25 1 5 2 5 Initiator supply U for 2 and 3 wire termination 1 6 26 16 26 16 26 1 6 2 6 Ground contact GND for 3 wire termination Each channel on the con
27. for G4 Based Controller Boards Using PC Bus and Ethernet see Ordering Data on page 4 The following services are supported Services for remote access to the DDI DDI DevOpenNode DDI DevCloseNode DDI DTI ReadData DDI DTI WriteData DDI DTI ReadWriteData GetlBSDiagnostic The module only supports the process data channel DTI Access to the mailbox channel MXI is not supported and thus rejected with the corresponding error message Read Access O2hex ce se 16 bit OUT DIO Process data g r 7 O prar O O c D S Q A008 ge 40094c a test Special register 7046 en 02 14 1 Connection and Error Monitoring ETH SetDTITimeoutCtrl ETH ClearDTITimeoutCtrl ETH SetNet Fail ETH GetNet FailStatus ETH ClrNet FailStatus ETH_SetNet FailMode ETH GetNet FailMode 14 2 Services for Process Data Monitoring ETH ActivatePDinMonitoring ETH DeactivatePDinMonitoring 14 3 Services for Ethernet Connection Management ETH InitiateManagement ETH AbortManagement ETH HardwareReset ETH EnableHardwareReset ETH_DisableHardwareReset 14 4 Structure of the DTI Area The special registers can only be accessed individually with a length of 2 bytes In this way invalid parameters can be rejected selectively Byte Aoroa DTI IN DTI OUT Todt 16 bit
28. forgets the IP address set the reconfiguration button can be used to access the module again lf the reconfiguration button is pressed during power on all permanently stored parameters are reset to the default upon delivery The reconfiguration button must be pressed until the BOOT LED and the RDY LED are on As soon as the reconfiguration button has been released the module starts with the default parameters 7046_en_02 THE ONLINE DISTRIBUTOR OF ELECTRONIC COMPONENTS ILB ETH 24 DI16 DIO16 2TX 10 Web Based Management WBM The ILB ETH 24 DI16 DIO16 2TX module has a web server which generates the required pages for web based management and depending on the requirements of the user sends them to Factory Manager or a standard web browser Web based management can be used to access static information e g technical data MAC address or dynamic information e g IP address status information or to change the configuration password protected 10 1 Calling Web Based Management The ILB ETH 24 DI16 DIO16 2TX web server can be addressed using the IP address if configured correspondingly The module homepage is accessed by entering the URL http lt ip address gt in the address line of your browser Example http 192 168 2 81 Inline Block IO last update 16 24 19 ILB ETH 24 DI16 DIO16 2TX 1 General Instructions I Device Information I Device Configuration C Block 10 Figure 8 WBM homepage
29. ge Nominal input current for Un Current flow Delay time Permissible cable length to the sensor Use of AC sensors Error message to the higher level control system 7046_en_02 Short circuit overload of outputs 32 16 permanent 16 freely selectable 2 and 3 wire technology According to EN 61131 2 Type 1 Uimax lt 5 V Unmin gt 15 V Sensor supply Us ground 24V DC 30 V lt Un lt 30 V DC 5 mA typical Linear in the range 1 V lt Un lt 30 V lt 500 us 100 m AC sensors in the voltage range lt Uj are limited in application Sensor supply not present Short circuit overload of sensor supply PHOENIX CONTACT 7 Power Dissipation Formula to Calculate the Power Dissipation of the Electronics THE ONLINE DISTRIBUTOR OF ELECTRONIC COMPONENTS ILB ETH 24 DI16 DIO16 2TX n m Pror 1 68 W lagg Iero X 0 06 Q E 0 129 W 1 x0 280 1 0 35 V 0 125 W fed Where Prot Is36 Is710 l n lli j m Limitation of Simultaneity No limitation of simultaneity derating Derating Ambient Temperature Ta Total Current hot Outputs Connectors 3 to 6 25 C to 30 C 8A 30 C to 60 C 8 A Ta 30 C x 0 2 A C Sensor Supply Connectors 3 to 6 25 C to 30 C 2A 30 C to 60 C 2 A Ta 30 C x 0 05 A C Sensor Supply Connectors 7 to 10 25 C to 30 C 2A 30 C to 60 C 2A Ta 30 C x 0 05 A C Approvals For the latest approvals please visit www download phoenixcontact com 704
30. he module the firmware is started The following LED sequence is shown ED meaning SS BOOT flashing Boot Loader is started BootP requests are sent Starting the Firmware BOOT ON Firmware is extracted BOOT and RDY ON Firmware is started RDY flashing 7046_en_02 THE ONLINE DISTRIBUTOR OF ELECTRONIC COMPONENTS ILB ETH 24 DI16 DIO16 2TX PHOENIX CONTACT 16 9 3 Sending BootP Requests Initial startup During initial startup the module transmits a BootP request without interruption until it receives a valid IP address The requests are transmitted at varying intervals 2s 4 s 8s 2 s 4 s etc so that the network is not loaded unnecessarily If valid IP parameters are received they are saved as configuration data by the module Further restarts If the module already has valid configuration data and BootP is not disabled it only transmits three more BootP requests on a restart If it receives a BootP reply the new parameters are saved If the module does not receive a reply it starts with the previous configuration If BootP is disabled and a valid configuration is available the module starts immediately 23 9 4 Reconfiguration Button For presetting the IP address via BootP you can use Factory Manager see Ordering Data on page 4 or any BootP server available By modifying the network parameters you can block your access to the module via Ethernet If for example BootP is disabled and the user
31. lled setting resetting of the I O station outputs in the event of an error If outputs of the stations are set ensure access of the controlling process to the station In the event of an error e g network line interrupted or function error in the controlling process the module can react appropriately By default upon delivery the watchdog is activated with 500 ms timeout The first write process activates the process data watchdog The next write process is expected during timeout default 500 ms During error free operation the write process is performed during timeout and the watchdog is restarted triggered 23 Reading calls do not trigger the process data watchdog NET FAIL If there is no triggering during timeout an error occurred Two responses follow The selected fault response mode is executed The NetFail signal is set the Net Fail LED is red The reason for setting the NetFail signal is listed in the reason code For safety reasons the user cannot stop the watchdog once it has been activated In case the user terminates the controlling application there is no watchdog triggering when timeout has expired the NetFail signal is set and the selected fault response mode is executed After the watchdog has performed its task the outputs are only enabled again after acknowledgment When the error is acknowledged the watchdog is restarted This means that it must be triggered during timeout other
32. module is grounded when it is snapped onto the DIN rail To ensure reliable functional earth grounding of the module even when the DIN rail is dirty or the metal clip is damaged Phoenix Contact also recommends grounding the module via one of the FE terminal points 7046 en 02 onlinecomponents com THE ONLINE DISTRIBUTOR OF ELECTRONIC COMPONENTS ILB ETH 24 DI16 DIO16 2TX PHOENIX CONTACT 15 9 9 1 Startup Default upon Delivery Default Settings By default upon delivery the following functions and features are available For SNMP and web based management the password is private IP configuration IP address Subnet mask Default gateway BootP requests Software update Software update on next reboot TFTP server IP address Downloadable file name Port configuration Mode of port 1 Mode of port 2 SNMP configuration Name of device Description Physical location Contact Trap configuration Sending traps Trap manager IP address 1 to 5 Services HW watchdog Process data monitoring Process data watchdog timeout Fault response mode 0 0 0 0 0 0 0 0 0 0 0 0 Enable Disable 0 0 0 0 Auto negotiation Auto negotiation Inline Block I O ILB with 16 IN and 16 IN DUT Unknown Unknown Disable 0 0 0 0 Enable 500 ms Reset fault mode default Ev By default the ILB ETH 24 DI16 DIO16 2TX module has no valid IP parameters 9 2 After you have applied voltage to t
33. nectors three to six If a channel is used as input this input must can either be used as input or output A not be set as an output configuration is not required ERE 7 5 Terminal Point Assignment of the Input Connectors nies 7 to 10 in Figure 6 on page 13 Terminal Point Connector 7 Connector8 Connector 9 Connector me EE een Dr 14 1 1 2 1 Signal input IN r nat tha Sensor voltage Ujs for 2 and 3 wire termination 2 eer ees ln Ground contact GND for 3 wire termination aga 1424 44 24 4424 Sal npat ON 1 5 25 11 5 2 5 11 5 25 1 5 2 5 Initiator supply Uj for 2 and 3 wire termination 1 6 26 1 1 6 26 16 26 1 6 2 6 Ground contact GND for 3 wire termination 7046_en_02 PHOENIX CONTACT 14 8 Connection Example de 25 ww Ou QE OG Op Qu OG Op Oo ETHERNET 2TX 704601007 Figure 7 Connection example The numbers above the module illustration identify the connector slots Ev The module has an FE spring metal clip on the bottom of the electronics base This spring creates an electrical connection to the DIN rail Use grounding terminals to connect the DIN rail to protective earth ground The
34. s 8 A Short circuit and overload protected outputs The ILB ETH 24 DI16 DIO16 2TX module is designed for SELV operation according to DIN VDE 0805 EN 60950 IEC 60950 on page 4 Please refer to the Mounting and Removing Inline Block IO Modules application note see Ordering Data Make sure you always use the latest documentation It can be downloaded at www download phoenixcontact com A conversion table is available on the Internet at www download phoenixcontact com general 7000 en 00 pdf 23 For OPC server use an example configuration file can be downloaded at www download phoenixcontact com DOGO M000 Weonnc ODE INSPIRING INNOVATIONS onlinecomponents com THE ONLINE DISTRIBUTOR OF ELECTRONIC COMPONENTS ILB ETH 24 DI16 DIO16 2TX Table of Contents j PENN 1 1 1 EEE Se 1 1 2 ML FRI 1 1 3 Combined Input and Output Features rrrrrrarrrrrannroranrrornnnrrnnnnnrrnnnnnnrnnnrnrnnnrrnnnnnennnnennnnsennnunensenransnnnassnnnn 1 2 EDNA 4 gt E 1ea 1102 DE GE EE EE NE eee reer eee 5 4 Internal Circuit Diagram rranrnnnnornnrrnanennnnnnnnrnnnnrnannrnnnennnnennnnnnanenanennnsennnddnnennanenneennnsennnenenunene 9 5 Relevant Notes r rrnnnrnnnnrnnnrnnrvnnsvnnnnnnnnnnnnnnnrnnnvnnnrnnevnnennnnnnnnnnennnner rer ap cccecccscscesscsessceeeoees 10 6 Local Diagnostic and Status Indicators rrrrnrrnrnnrrnnnnrvrnnrrnnnnrvrnnrrnnnnrnnnnernnnnernnnrrrnerennnnsennsnennnn 10 7 Connecting Ethernet the
35. t circuit sensor supply overload 1 Sensor supply U missing 1 Sensor supply U missing Reserved 704601008 Figure 15 Assignment of the I O diagnostic register 23 The diagnostic register always indicates the current status 15 3 Address Modbus Register 6 DDI Word starting with OChex This register can be used to read the NetFail reason after setting the NetFail signal If no NetFail signal is present the register is 0 For a list of the reasons please refer to Section Reasons for Fault Response on page 24 NetFail Reason PHOENIX CONTACT 29 16 Special Register 16 1 Modbus Connection Timeout Modbus Register 1280 A monitoring mechanism can be activated for every Modbus TCP connection in order for the ILB ETH 24 DI16 DIO16 2TX module to detect an error in the network e g defective cable or in the client operating system crash or error in the TCP IP protocol stack and react accordingly The monitoring mechanism is activated via the relevant TCP connection upon the first read or write procedure To change the timeout value for the relevant TCP connection write the new timeout value to the timeout table to the special address 1280 using functions fc 6 or fc 16 The value of this entry is the value of the timeout table The time is specified in milliseconds in the range from 200 ms to 65000 ms A timeout value of 0 deactivates the monitoring function Values between 1 ms and 199 ms and
36. tage Uour Differential voltage at lhom Nominal current lhom per channel Total current Protection Nominal load Ohmic Lamp Inductive Switching frequency with nominal inductive load Overload response Response with inductive overload Reverse voltage protection against short pulses Resistance to permanently applied reverse voltages Response upon power down Limitation of the voltage induced on circuit interruption One time unsolicited energy Protective circuit type Overcurrent shutdown Maximum output current when switched off THE ONLINE DISTRIBUTOR OF ELECTRONIC COMPONENTS ILB ETH 24 DI16 DIO16 2TX 16 freely selectable 2 wire technology 24V DC lt 1V 0 5A 2x4A Short circuit and overload protection 489 12 W 12 W 12 VA 1 2 H 50 Q 0 5 Hz 1 2 H 50 Q maximum Auto restart Output may be damaged Protected against reverse voltages Protected against reverse voltages permissible current 2 A maximum The output follows the supply voltage without delay 41 0 V 1J maximum Integrated free running circuit in the output chip 0 7 A minimum 10 pA 23 When not loaded a voltage can be measured even at an output that is not set Error message to the higher level control system Digital Inputs Number Connection method for sensors Input design Definition of switching thresholds Maximum low level voltage Minimum high level voltage Common potentials Nominal input voltage Uj Permissible ran
37. te AH ILB INSTALLATION 9014931 1 Firmware Updates for Devices Supporting TF TP Firmware Updates AH EN TFTP FIRMWARE UPDATE 7090 1 application note Driver Reference Manual for G4 Based Controller Boards Using PC Bus and IBS PC SC SWD UME 2745172 1 Ethernet user manual 7046 en 02 PHOENIX CONTACT 4 3 Technical Data General Data Housing dimensions with connectors width x height x depth Weight Operating mode Transmission speed Type of sensor and actuator connection Housing Dimensions THE ONLINE DISTRIBUTOR OF ELECTRONIC COMPONENTS ILB ETH 24 DI16 DIO16 2TX 156 mm x 55 mm x 141 mm 500 g with connectors Process data mode with 4 bytes 10 Mbps and 100 Mbps with auto negotiation and auto crossover 2 and 3 wire technology 7151B005 Figure 1 Housing dimensions of the module dimensions in mm Ambient Conditions Regulations Ambient temperature operation Ambient temperature storage transport Humidity operation storage transport Air pressure operation Air pressure storage transport Degree of protection according to IEC 60529 Class of protection Air and creepage distances Housing material Pollution degree according to EN 60664 1 IEC 60664 1 EN 61131 2 IEC 61131 2 Surge voltage class 7046_en_02 Developed according to VDE 0160 EN 50178 IEC 6
38. ty classes 0 and 1 13 5 Modbus Table Modbus Register Table 16 Bit Words Modbus Input Discretes Table Bits 163 Process data Modbus Coil Table THE ONLINE DISTRIBUTOR OF ELECTRONIC COMPONENTS ILB ETH 24 DI16 DIO16 2TX 13 4 Modbus Function Codes The following function codes are supported Function Code fe Rees O ooo fo2 Read input discretes fc1 fc2 fc3 fc4 fc6 f fa Readinput registers e Write snge regse 0 o Readony Digital inputs DIO Read only Digital inputs DI Read write Digital outputs 2 gt d 4 Read only_ Status register VG 7 O prar m O c D S Q Read only I O diagnostic register Readonly NetFail reason T Read only IBS diagnostic register for compatibility with FL IL 24 BK Read only IBS para register for compatibility with FL IL 24 BK Special register 2006 7046_en_02 428011 Read write Modbus timeout connection monitoring 9000 E 2002 read Faut response mode 9008 Rvs Nota test came value as rear 6 Read write Process data watchdog timeout Read write Command register PHOENIX CONTACT 25 THE ONLINE DISTRIBUTOR OF ELECTRONIC COMPONENTS ILB ETH 24 DI16 DIO16 2TX 13 6 Process Data Assignment Modbus Assignment of the Terminal Points to the OUT Process Data Word Slots 3 to 6 Word bit view Word Word gt et Heemi r de ed ed i 0 Module 3707 Femina pot gn 24 1a 2
39. values greater than 65000 ms generate exception response 3 ILLEGAL DATA VALUE EJ Connection monitoring with the new timeout values is only activated after a Modbus TCP function has been executed on the relevant TCP connection After the first access by a Modbus TCP function all other access must be carried out using the entered timeout value Otherwise fault response mode is activated and the Modbus TCP connection is disabled PHOENIX CONTACT 03 2007 7046_en_02 onlinecomponents com THE ONLINE DISTRIBUTOR OF ELECTRONIC COMPONENTS ILB ETH 24 DI16 DIO16 2TX 16 2 Process Data Watchdog Timeout Modbus Register 2000 DDI Word starting with 4000 4ec Setting or reading the timeout value for the process data watchdog The time is specified in milliseconds in the range from 200 ms to 65000 ms A timeout value of 0 deactivates the watchdog see also page 23 16 3 Fault Response Mode Modbus Register 2002 DDI Value starting with 4004 Setting or reading the fault response mode For information on fault response mode settings please refer to Section Setting the Required Fault Response Mode on page 22 16 4 Command Register Modbus Register 2006 DDI Value starting with 40124ec The network interface command register can be used to transmit commands with basic functions to the module using the Ethernet host controller e g PLC Function Code 0000hex 0002hex NetFail a
40. wise an error is detected again Configuration of the Process Data Watchdog Timeout can only be changed if the watchdog is in INIT state The INIT state is present After power up as long as process data exchange has not taken place In case of timeout and if fault response has been activated and if NetFail has not yet been acknowledged Process data watchdog timeout can be configured from 200 ms to 65000 ms Timeout can be set using the web based management by writing to Modbus register 2000 or using DTI byte address 4000 PHOENIX CONTACT 23 7046_en_02 Deactivating the Process Data Watchdog The process data watchdog can only be deactivated if it is in INIT state For deactivation the timeout value is set to Zero Status INIT Write OK ClearNetFail Watchdog Timeout gt 0 ACTIVE Write_OK Watchdog Timeout lauft ab Set Net Fail Fault Response 61560029 Figure 14 Status diagram of the process data watchdog 12 3 Fault Response Acknowledgement The NetFail signal can be acknowledged using the web based management by writing command 0x0002 to the command register Modbus register 2006 or DTI byte address 4012 or using the ETH CirNet FailStatus function Reasons for Fault Response The web based management Modbus register 6 DTI byte address 12 or the ETH GetNet FailStatus service can be used to request the reasons for fault response mode 7046_en_02