1. Thermo Recorder ThermoWorks TR 71U TR 72U ach pata Logger with use Connection Our compact lightweight TR 71U 72U units allow you to effortlessly measure and record temperature in a range of 60 to 155 C and humidity from 10 to 95 That data can then be transferred via high speed USB cable to your computer whereby our exclusive software empowers you to create colorful graphs and tables for saving or printing k v z 5 Easy to Use Software makes Graph and Table Creation a Snap T amp D Corporation Thermo Recorder 2Ch Data Logger USB Connection TR 71U 72U Easy USB Connection Multiple Units OK Real time Monitoring and Graph Display Adjustment Function Enabled Software 1 Year Operation with only 1 AA Battery TR 71U TULLU UWL SS TR 72U ee Measure Record 2 Measurement and Recording Channels in Each Unit TR 71U TR 72U Thermo Recorders are data loggers capable of measuring displaying and recording temperature and humidity data TR 71U has two temperature channels and TR 72U has one temperature and one humidity channel The data recorded into the TR 71U TR 72U units can then be downloaded quickly via USB cable to your computer whereby with our exclusive software you can easily process the data into graphs tables save to files and or print it out Moreover it is possible to connect more than one unit at the same time Wide Temperature Measuring Range 60 C to 1
2. Others Data List Display Calculation Range Settings Data Maintenance LCD Display Ch1 only Ch2 only alternating display Measurements Edit Recording Conditions Delete Data by Channel Recording Status Battery Life Warning Amount of Recorded Data Re order Data by Channel Unit of Measurement Other Serial Port Auto Find Function Power AA alkaline battery LR6 File Output T amp D Common Data File Text File CSV etc Battery Life About 1 year 2 Selected Range or File for Entire Period Data Back up Activated when battery power is low or when switch is off About 1 year Printing Graphs Tables Interface USB Communication Cable option RS 232C Compatible OS Microsoft Windows 2000 XP English USB Communication Time When downloading 1 unit of full data about 8 seconds Microsoft Windows 98 Me English Dimensions H55mm x W78mm x D18mm Microsoft WindowsNT 4 0 English 1 Weight About 62g Including one AA battery PC CPU IBM Compatible with higher than Pentium 90MHz Attached Sensors TR 0106 x 2 TEP Resin coated sensors TR 3100 x 1 Temp Humidity Sensor USB Port 1 0 1 1 Accessories AA alkaline Battery LR6 x 1 User s Manual Warranty x 1 Memory More than 16MB included in package USB Cablex 1 US 15C length 1 5m Hard Disk More than 4 MB of free space Data will need more space Software Set x 1 User s Manual Warranty x 1 Monitor VGA 640 x 480 more than 256 colors 1 There are two types of temperature sensor for TR 71U dependi
3. 0 3 C 20 to 80 C Average 0 5 C 40 to 20 80 to 110 C TR 1C30 3000 Sensor Extension Cable Cable Length 3m Note Only one cable per sensor Can not be used with 1 Temperature Humidity sensor TR 3110 or TR 3100 TR 5C10 wa Sensor Extension Cable Cable Length 1m Note Only one cable per sensor Can not be used with 1 Temperature Humidity sensor TR 3110 Materials Vinyl Chloride Coated Wire TR 07C 1000 Serial Communication Cable Cable Length 1m Note For communication with computer TR 4C10 Serial Communication Cable Cable Length 1m Note For communication with RTR 57C unit mm TR 07K2 TT PT Wall Attachment fy Included Wall Mount Screws x 2 Double Sided Adhesive Tape x 1 D D 32 Material ABS Resin L 56 600 o D j TR 0706 Stainless Protection Sensor Cable Length 0 6m Thermal Constant Time In agitated water Approx 18 Sec 5 6 Materials 1 Thermistor 2 TPE resin shielded sensor 3 TPE resin shielded wire 4 M3Screw Hole 5 Compaction Tube 6 Stainless Pipe SUS304 7 Stainless Pipe SUS316 avin Product Specifications Software Specifications unit TR 7AU TR 72U Measurement Channel 2 Channels Select from Ch1 internal Ch 2 external 2 Channels Temperature and Humidity Compatible Devices TR 71U
4. TR 72U Measurement Item Temperature Temperature Humidity Communication Recording Start Programmed Start Immediate Start Recording Stop Internal Sensor 10 to 60 C 10 to 60 C Functions Main Unit Settings Recording Interval Recording Method Upper and Lower Limits External Sensor 40 to 110 C 0 to 50 C 10 to 95 RH Downloading of Recorded Data Optional Sensor 60 to 155 C 1 40 to 110 C Temp Humidity Graph Temperature and Humidity Graphs for each Channel Measurement Accuracy Average 0 3 C 20 to 80 C 5 RH Graph Display Zoom in out and scroll with mouse or keyboard Standard Sensor Average 0 5 C 40 to 20 80 to 110 C At 25 C 50 RH Change Channel Colors Turn ON and OFF Channel Display Measurement Resolution 0 1 C 1 RH Data Display Channel Name Recording Interval Number of Readings Sensor Materials Thermistor Macromolecular Highest Lowest and Average Readings Unit of Measurement Humidity Sensor AB Cursor Dates Times and Data Readings Recording Interval 1 2 5 10 15 20 30 Seconds 1 2 5 10 15 20 30 60 Minutes Total of 15 choices Calculated Difference between Cursor A and B Recording Capacity 8 000 Readings x 2 Channels Number of Channels 8 Channel Simultaneous Display and Processing Recording Method Endless Loop Method Overwrite from the oldest data when recording capacity is full Possible to process mixed data from TR 71U and TR 72U units up to 4units One Time Method Stop recording when recording capacity is full
5. 2 connected Graph Table Printing Function You can print out in color or monochrome the graphs just as they appear on your screen You can also print out in table form all of the data in order of date and time Creating Text Files You can create Text Files CSV format etc to allow you the option of processing and managing your data using Excel Lotus or any other popular spreadsheet software Optional Sensors OTR 71U 4 TR 72U TR 1106 Teflon Shielded Sensor Cable Length 0 6m Thermal Constant Time In the Air Approx 15 Sec In agitated water Approx 2 Sec TR 1220 Stainless Protection Sensor Cable Length 2m Thermal Constant Time In the Air Approx 36 Sec In agitated water Approx 7 Sec TR 1320 Stainless Protection Sensor Cable Length 2m Thermal Constant Time In the Air Approx 12 Sec In agitated water Approx 2 Sec 1 2 3 A 70 30 2000 A Pr D Materials 1 Thermistor 2 Stainless Pipe SUS316 3 Teflon Compaction Tube 4 Teflon Resin FEP Shielded Possible Measurement Range 60 to 155 C Sensor Temperature Durability 70 to 180 C Water Resistant Ability Splash Resistant Measurement accuracy Average 0 5 C 40 to 80 C Average 1 0 C 60 to 40 80 to 100 Average 2 0 C 100 to 155 C TR 3110__ amp 2 m Humidity and Temperature Sensor Cable Length 1m TR 3100 Humidity and Temperature Sensor Materials 1 Temperature Humid
6. 55 C The external sensor that comes with the TR 71U can measure and record from 40 C to 110 C while optional sensors can give you a range of 60 C to 155 C There is an array of optional external sensors to meet your every need Humidity Measurement Range 10 to 95 RH The two channel external sensor that comes with the TR 72U can measure and record temperature from 0 to 50 C and humidity from 10 to 95 RH Large Data Capacity 8 000 Readings X 2 Channels Each channel can record up to 8 000 readings giving you about one year of continuous recording at a recording interval of 60 minutes 15 Recording Intervals 2 Recording Methods You can select from 15 recording intervals from one second to one hour There are also two methods of recording to chose from One Time Method Recording stops when 8 000 readings have been recorded Endless Loop Method When 8 000 readings have been recorded the oldest data is overwritten and recording continues Accurate Compact Lightweight and Affordable Our exclusive design and technology has allowed us to create a highly accurate yet compact and lightweight unit 55x78x1l8mm 62g that is unbelievably affordable Ready to Use All in One Package Everything you need to get started main unit sensor battery software communication cable and user s manual is included in this All in One Package All you need to do is supply the computer Connect Download and Analyze Reliab
7. e software allows you to control all aspects of set up for any TR 71U TR 72U unit as well as to print and to create text files tables and colorful graphs from the recorded data Up to 8 Channels of Data can be Processed at One Time post adjusted value By simply downloading the data from the main unit a colorful graph representing that data will be automatically created Up to 8 channels 4 units of data can be represented in one graph Bp Vidrect 0e_test 1409786153 1409786153 70031776 113536 trx Temperatu MeL Yew ToD Gaia Neb a BSG Gay lease Sie 1 2 3 Adjustment Function By setting adjustment values beforehand you can record and display the post adjusted measurement values You can choose from two adjustment methods l point and 2 point Adjustment will be carried out using an adjustment equation of Y aX b where X is the pre adjusted measurement value and Y is the Current Readings Monitoring Display With our exclusive software you cannot only monitor the current measurements at a set interval but can view those measurements in a continually changing graph You can simultaneously display the current measurements and corresponding graphs for the number of units you have 122009 t2709 To view help Press F 1 12 2003 12 2003 12009 2700 1322400 172900 Cursor A 1200003 122744 CQursor B 12000003 13 2590 A lt gt B 0 000766 Calculation Range trom 12 202003 132100 to 1220 2003 13 354
8. g environment recording interval communication frequency and ambient temperature The above battery life test was carried out using a brand new battery and in no way do we guarantee a battery s life Easy to Read Multi Functional Display The easy to read LCD displays present temperature recording condition battery life warning and unit of measurement ne PRIA com ENESES 1 The channel number of the measurement being displayed will appear 2 The recording condition will appear ON Recording in progress BLINKING Waiting for programmed start 3 After every 2000 readings the scale will be marked from left to right 4 This will appear when data is being sent or received 5 ONETIME When the number of recorded readings reaches 8000 FULL will appear in the unit s LCD display and recording will automatically stop ENDLESS When the number of recorded readings reaches 8000 the oldest data reading will be overwritten and recording will continue 6 When the battery power becomes low this will appear in the LCD display If the battery power becomes even lower SLP will appear and normal operations will stop If the ig signal appears please change the battery as soon as possible 7 The unit of measurement C F for the display will appear 8 Current measurements or operational messages such as FULL or SLP will appear Standard Software T amp D Recorder for Windows Easy to use Windows comapatibl
9. ity Sensor 2 Polypropylene resin 3 Vinyl Chloride Coated Wire D Humidity Measurement Range 10 to 95 RH Temperature Measurement Range 0 to 50 C Sensor Durability Range 10 to 55 C unit mm Humidity Measurement Accuracy 5 RH at 25 C and 50 RH Service Life lyear under normal conditions Operational Conditions No Dew Condensation or Water Leakage No contact with organic solvents solutions or gasses emitted from spoiled foods TR 0106 TPE resin shielded sensor Cable Length 0 6m Thermal Constant Time In the Air Approx 75 Sec TR 0206 Stainless Protection Sensor Cable Length 0 6m Thermal Constant Time In the Air Approx 75 Sec TR 0306 Stainless Protection Sensor Cable Length 0 6m Thermal Constant Time TR 0406 Stainless Protection Sensor Cable Length 0 6m Thermal Constant Time TR 0506 Stainless Protection Sensor Cable Lenth 0 6m Thermal Constant Time In agitated water Approx 18 Sec In agitated water Approx 20 Sec In agitated water Approx 20 Sec 15 600 ONE eee PN 1 2 3 50 600 a 4 1 5 3 ia 40 600 a 1 6 3 Only stainless section is water resistant 200 600 _ 1 6 3 Only stainless section 1s water resistant 600 T A Only stainl ti 1 6 3 e a Possible Measurement Range 40 to 110 C Sensor Temperature Durability 50 to 115 C Measurement Accuracy Average
10. le Backup Function We have eliminated the worry of losing data due to power loss or the switch being accidentally turned off When Battery Power becomes Low When battery power becomes low a battery life warning will appear on the unit s display indicating that the battery should be changed If within a short time the battery is changed measurement and recording will not be interrupted and there will be no data loss If the battery is not changed the unit will automatically go into SLEEP mode whereby measurement and recording will stop but due to our BACK UP FUNCTION data will not be lost and will remain saved for up to one year leep Mode Battery Life ry Indicator Warning Indicator When the Switch is turned OFF If while recording the power switch is accidentally turned OFF data will not be lost but will be saved for up to one year from the time it was switched OFF Note Even if the unit is in sleep mode it needs battery power Hence a total loss of battery power or removal of the battery will result in the loss of data One Year Continual Use on One Battery Using our specially designed low energy consumption circuit this unit can run on one AA Alkaline battery for up to one year of continued use No need to worry about where you place it as the battery will allow you to measure and record over long periods of time no matter if the unit is in transit or in a distant place Note Battery life will depend on the recordin
11. ng on measurement range 1 USB communication with TR 71U 72U data loggers cannot be carried out using WindowsNT4 0 2 Battery life depends upon the measuring environment recording interval and quality of the battery being used System Setup AA Alkaline battery Software LR6 x 1 T amp D Recorder for Windows Standard Temperature Sensors TR 0106 x 2 Install Standard Humidity MF 5 f 7 Le and Temperature Sensor USB Communication Cable ORIIRE US 15C TR 3100 Connect Printout 270 North Main Street Suite D Alpine UT 84004 Ph 800 393 6434 Fax 801 756 8948 www thermoworks com CUD ThermoWorks