1. Parameters Image Up Down Image Left Right Night Vision Mode Wide Dynamic Mode adjustable HD Brightness Saturation Contrast Image Up Down Image Left Right adjustable Functional Interfaces Audio Interface Mic input and 1 linear output optional Alarm Input 1 alarm input normally opened or normally closed optional Alarm Output 1 switch output maximum working voltage AC 120V 1A DC 24V 1A Motion Detection Allow 4 independent detection areas Control Interface 1 RS485 Memory Support TF card for video storage and image capture 32G maximum optimal Network Interface 10Base T 100Base TX Ethernet interface WiFi 802 11b g wireless optional Supported Network Protocols TCP IP HTTP TCP ICMP UDP ARP IGMP SMTP FTP DHCP DNS DDNS NTP UPNP and RTSP etc Working Environment Input Power DC 12V Z1 5A PoE Ethernet power supply comply with 802 3af regulation optional Max Power Consumption 10W Working Temperature 20 55 C Working Humidity 10 95 RH Level of Protection IP66 Installation Mode Wall Mount Overview 1 4 Product Appearance LIE Stereoscopic Drawing Wall mounted Camera Support E Dimensional Drawing in mm rm 287 0 1 Left View User s Manual for ZKIR3 Series IR Day amp Night Weatherproof Bullet IPC V1 7 107 8
2. e 1 Power Interface Connect to the adapter The device employs the power supply of DC 12V and no lower than 1 5A Do not use any different power supply as it may damage the device 2 Network Interface 10 100M self adapting Ethernet interface is used to connect the device with various network equipments such as switch router and hub When it is connected to 10M network the orange lamp is on When it is connected to 100M network the green lamp is always on This interface can also employ Ethernet power supply POE optional and allow the transmission of power and data through Ethernet cable Overview 1 PoE Swicth Ese La Lee Reset Button When the device fails to function during incorrect operation or accidental failure e g forget IP address or password or it is used in different scenes press down the button for above 5s after a delay of 30s from powering on to restore the device to its factory default The default user s name is admin the default password is admin and the default IP address is 192 168 1 88 Alarm Interface Connect to alarm input and alarm output When the device receives an alarm from alarm output or Web motion detection this interface can send a signal to alarm output to realize real time monitoring and overall protection while triggering a remote alarm The specific interfaces are presented in the following fig
3. User s Manual for ZKIR3 Series IR Day amp Night Weatherproof Bullet IPC V1 7 5 Use the standard power cord when the power supply is too far away from the device and consider the voltage drop caused by long distance 6 Read through the instructions for connecting terminal and wire strictly according to interfaces Any damage to the device due to improper operation will be disqualified from the guarantee 7 All the exposed parts of connecting terminal should not exceed 5mm in order to prevent any accidental contact from damaging the device Uncovered cable should be less than 5mm 8 Mount the relay equipment in the middle to avoid signal attenuation when the straight communication distance from the device to the incoming equipment exceeds 80m Please use repeater when exceeding 80m 9 When RS485 is employed if the communication distance exceeds 100m the final equipment on the 485 bus must be connected to a 1202 terminal resistance in parallel 10 Pay attention to provide lightning protection if the device is mounted outdoor Do not touch the device during lightning 12 Installation and Network Configuration 11 Use the device in the working conditions Ambient temperature 20 C 55 C ambient relative humidity 10 959 RH my a NLZ PAN 12 Keep the cle
4. Ctrlt DN Advanced pen File CtrltShiftt ei pen Folder Ctrl F 2 Ctrl D Ctrl N View Help ef pen Capture Device Ctrl C Open Location from clipboard CtrltV Recent Media d Save Playlist to File CtrltY Convert Save CtrltR te Streaming Ctrlts XX guit Ctrl g 3 Type in the network URL in the form of rtsp lt IP address gt lt RTSP port gt lt stream code Open Media ES Wetwork Ef Capture Device Network Protocol Please enter a network URL tsp 192 168 80 187 11 http xample com stream avi rtp mms ampl rtsp Y ampl http www rourtube oO Show more options 19 User s Manual for ZKIR3 Series IR Day amp Night Weatherproof Bullet IPC V1 7 4 Click Play and the media player will play the real time video of the device T d Y Mo emo eif es ECELCAREEXEZT Note 1 The default RTSP port of device is 554 If it must be modified please refer to User Manual Using Browser for Video Surveillance in the supplied CD 2 If it is necessary to learn about how to use RTSP media player for video surveillance please refer to User Manual Using Browser for Video Surveillance in the supplied CD 20 Accessing device 3 3 Using Mobile Devices If it is necessary to use mobile devices for video surveillance please firstly ensure the device can be accessed on Internet Please ref
5. HD cam to support the browsing by 14 users simultaneously 4 in primary code stream and 10 in secondary code stream SD cam to support the browsing by 20 users simultaneously 10 in primary code stream and 10 in secondary code stream Overview 1 3 Technical Parameters Product Name IR Waterproof Bullet IPC Product Model ZKIR372 ZKIR373 ZKIR352 ZKIR353 Cam Properties Image Sensor 1 3 Megapixel Progressive 1 3 2 Two megapixel CMOS Sensor Progressive CMOS Sensor WDR HD HD Image Resolution 1280x720 Day Night Switch IR Cut filter switch Type of Lens 12mm fixed lens for ZKIR373 353 343 323 4mm fixed lens for others Minimum Illumination 1 Lux IR lamp off 0 Lux IR lamp on IR Lamp 48 pcs 5 IR lamps Effective Projection 10 15m 20 30m 10 15m 20 30m Distance IR Projection Angle 60 25 60 P i Video Coding Primary Processor Hi3512 Operating System Embedded Linux Video Compression Algorithm H 264 main profile level 3 Audio Compression Algorithm G726 G 711 Video Compression Code Rate 32 6114 Kbits s adjustable Video Resolution Primary Code Stream 1280x720 Secondary Code Stream 320x240 Video Frame Rate 1 25 frames optional Video WDR HD Brightness Saturation Contrast Illumination Sensitivity Shutter User s Manual for ZKIR3 Series IR Day amp Night Weatherproof Bullet IPC V1 7
6. NS NTP and UPNP etc Aluminum alloy with IP66 protection and extremely strong resistance to dust water corrosion and impact Large sunshade to well protect the machine from sunshine for cooling and more suitable for outdoor application X Snap on base to simplify the installation User s Manual for ZKIR3 Series IR Day amp Night Weatherproof Bullet IPC V1 7 Safe and reliable socket head lock screws Double glass front cover for better optical isolation and mist prevention surface for better night viewing Three layer shield magnetic ring design to eliminate signal interference Numerous additional functions e g alarm audio talkback 485 control TF card and reset etc Support Ethernet power supply PoE 802 3af regulation optional Support WIFI 802 11b g n standard wireless network module optional IR Cut filters to automatically switch between day and night for optimal monitoring Double web indicator lamps for easy judgment of web status Analog video output interface for HD to facilitate site commissioning Self recovery from abnormality and auto reconnection after network interruption Automatically capture images during an alarm and send them to the designated email Support motion detection and external detector alarm Allow setting several alarm times and support the remote alarm linkage Support dynamic IP DHCP and dynamic domain name system DDNS Network time synchronization NTP
7. User s Manual for ZKIR3 Series IR Day amp Night Weatherproof Bullet IPC Document Version 1 7 Date 2012 10 Introduction This document mainly introduces the functional features installation process and access methods of ZKIR3 series IPC Important Notices Thanks for selecting our company s IPC Before use please read through the user s guide to avoid any unnecessary damage All functions depend on the actual product Since the product is subject to updating our company is not responsible for any difference from this guide and not liable for any dispute over different technical parameters from this guide The project is subject to any change without notice To learn more please visit our company s website www zkivision com or local office Table of Contents Table of Contents IV 1 T T Product Descriptoti uer recente eet eter tee aed 1 12 Product Beater ete ede er e eo tt eed 1 13 Technical Parameters unten n e ea FREE ET 3 LA enee DEE 5 1 5 Connecting Terminal REOR TP E Roter qnn 6 1 6 Basic Procedure i rito ee pe ae e egeta 10 2 Installation and Network Configuration eere eee enin tn etna 11 2 1 Hardware Installation eese nne 11 2 2 Operating Environment 15 2 3 Network Connection iccacccecesccecoencss sescessesnsenegeoeesneecdeasnuncersonsencaesnsencsntests 15 3 ACCESSING device sesesssseseesososeseseseseosososcocoscscscoroseseseseseoso
8. anness of double glasses in front of lens If too dirty clean them with soft fabric LI Schematic Diagrams of Installation 1 Press the installation template against the wall and make holes as marked on the template including screw holes and lead wire hole in mm P 13 User s Manual for ZKIR3 Series IR Day amp Night Weatherproof Bullet IPC V1 7 2 Align the screw holes of base with the holes on the wall and fix the base onto the wall 3 Tighten the screws after hanging the camera on the base and fix the camera onto the base 4 Loosen the side and bottom screws with a screwdriver to adjust the camera angle to the appropriate area and then tighten the screws 14 Installation and Network Configuration 2 2 Operating Environment Operating System Windows 98 Windows2000 2003 XP Vista Windows 7 CPU Pentium III 1GHZ or higher Memory 256MB or higher at least 128MB possibly affect performance and some functions HDD 1 5GB available Screen Resolution 800x600 or higher Browser IE6 0 or latest version A better computer can considerably improve the effect of monitoring so it is recommended to use a better computer for monitoring 2 3 Network Connection The device can be connected to network in two ways The first way is to connect to the network by means of Ethernet cable and the sec
9. c diagram Overview Alarm Output amp e Terminals s 3 Alarm COM NO switch Output Device Power Supply of Alarm Output Device Schematic Diagram of Alarm Output Normally Closed Connection RS485 Interface Supports standard 485 PTZ protocols for remote device control The device can be turned remotely and monitored in all directions The relevant parameters are set as detailed in User Manual Using Browser for Video Surveillance The specific interface is shown in following figure 485 E IN Ea 485 9 Wi 5 GN Audio Input Interface Connect to external audio acquisition e g MIC for sound acquisition as detailed in User Manual Using Browser for Video Surveillance Audio Output Interface Connect to audio player e g active speaker for sound broadcasting Analog Video Output Interface Special for SD camera and engineering commissioning After being installed and connected this interface can be used locally to connect with the image display device and adjust the camera angle to the appropriate monitoring area according to the realtime video User s Manual for ZKIR3 Series IR Day amp Night Weatherproof Bullet IPC V1 7 1 6 Basic Procedure 1 Unpack and check whether any component is missing 2 Connect the device to computer by means of patch cable 3 If your computer IP is in a netw
10. er to User Manual Using Browser for Video Surveillance in the supplied CD for more details about how to visit device on Internet 1 Install the media player in the supplied CD into the mobile device 2 Click the icon HIPlayer to enter the media player t RT 3 C 14 07 gt guu 4 2 2 Off sl gt O D X 3 Click the button E at the lower right corner to the setting interface type in the user name password domain name and port of the device or select a set device from the favorite 21 User s Manual for ZKIR3 Series IR Day amp Night Weatherproof Bullet IPC V1 7 LO ME r e 4 Click Play and the medial player will play the real time video of the device Note 1 The operating system of mobile device must be Android BlackBerry or iOS 2 As the internet service is required for watching video please consult with your internet service provider for specific charges 22 Accessing device 3 4 Using Video Surveillance Software ZKiVision Client Software is our company s free video surveillance software which can help manage and monitor multiple devices in a real time manner Install the software in the supplied CD and add devices to the software Then the real time monitoring can be started If needed to learn about how to use the video surveillance software refer to ZKiVision Client Software User Manual in the CD 23
11. ond way is to connect to wireless network optional 9 une eet AN Connect by Ethernet Cable 1 Use Ethernet cables to connect the device to network or directly to computer 2 Connect the power supply of the device 3 During normal connection if it is a 10M network the orange lamp is always on if itis a 100M network the green lamp is also on The physical connection with network is completed after the lamp shining 4 In the Start menu select Programs Accessories Command Prompt and input the ping command to the device address e g type in ping 192 168 1 88 If Request timed out does not pop up the device is successfully connected to network 15 User s Manual for ZKIR3 Series IR Day amp Night Weatherproof Bullet IPC V1 7 OR 1 The default IP address is 192 168 1 88 and the default HTTP port is 80 If needed to change IP address or port refer to Network Setting in User Manual Using Browser for Video Surveillance 2 If the device is in a network section different from computer refer to How to Visit IPC on Internet in User Manual Using Browser for Video Surveillance for the connection during different network sections Oa anean iipon iisa Connect to Wireless Network Before starting the wireless network connect the IPC to network by Ethernet cable visit the device through browser enter Network Setting interface and set the wireless network connection following the ope
12. ork section different from device IP please set it to the same network section as device IP such as 192 168 1 87 4 Log in the device through client software or browser to check whether the video functions normally 5 Adjust the code stream and other video parameters 6 Modify the network parameters of device and reboot the device 7 Repeat Step 3 8 Revisit the device through client software or browser to check till the video functions normally 9 Install the device and adjust the device angle to the appropriate area 10 Visit the device through client software or browse for video monitoring 10 Installation and Network Configuration 2 Installation and Network Configuration 2 1 Hardware Installation 1 Installation Notices Read through the guide for installation prior to installation Check whether any component is missing against the packing list if yes please contact your supplier Wire during power off If the device does not function normally during operation please cut off the power before check Do not connect cables when power is on Orr The wiring during power on may seriously damage the device which will be disqualified from the guarantee DC12V 1 5A Use the power supply of DC12V and no lower than 1 5A for the device or PoE power supply optional Too high or low voltage or AC power supply may cause the abnormal operation of the device 11
13. rating procedure as detailed in Network Setting in User Manual Using Browser for Video Surveillance 16 Accessing device 3 Accessing device There are 4 methods can be used to access the device Browser RTSP Media Player Mobile Device and Video Surveillance Software ZKiVision client software 3 1 Using Browser 1 Open a browser type in the dynamic domain name or IP address of the device e g http 192 168 80 123 press OK to open the following login interface prep m http 192 158 80 123 2 Type in user s name and password and click OK and the guide page will show as below initial use 3 Click Watch the video to enter Preview interface 17 User s Manual for ZKIR3 Series IR Day amp Night Weatherproof Bullet IPC V1 7 0012 07 25 10 23 45 O image Lattiat Linen von Mode Li wise Dinamu Mode ue When accessing the device via browser for the first time it is necessary to download the control More details about how to use browser for video surveillance please refer to User Manual Using Browser for Video Surveillance in the supplied CD 18 Accessing device 3 2 Using RTSP Media Player 1 Download and install a media player supporting RTSP protocol e g VLC media player 2 Open the media player select the menu Media Open Network Stream pop up the input interface of URL VLC media player Video Tools Open File
14. sesoeeososesesesessesesesessosesesee 17 3 7 Using BIOWSEP nero ee qr te xe e Eb teeny enemies 17 32 Using RISP Media Player eek e ere eR eta 19 3 3 Using Mobile Devices aire einer era eeaeee ieir eene 21 3 4 Using Video Surveillance Software 23 Overview 1 Overview 1 1 Product Description ZKIR3 colored 24h weather proof IPC employs the design of aluminum alloy up to the IP66 protection This product adopts two megapixel CMOS sensor or high quality SONY CCD sensor and is featured by IR lamp with long distance and wide range projection and favorable night viewing The optimized H 264 coding algorithm ensures its clearer and smoother video transmission The embedded Web Server allows a user s real time monitoring and remote control of PTZ conveniently by means of browser This product has mega pixels high definition HD or pixels standard definition SD optional and is wall mounted It is easy to install convenient to operate and universal indoor and outdoor It is suitable for all weather monitoring the short distance wide angle places with high protection rating such as communities factories and banks etc and any cases in need of remote network video 1 2 Product Features Hi3512 high performance multimedia processor supporting H 264 Main Profile video coding e Dual code stream suitable for various networks e Support all kinds of protocols such as TCP IP HTTP TCP UDP ARP SMTP FTP DHCP DNS DD
15. ure NC o COM e Alarm output H NO 5 gt GND o aimi e IN Alarm input The schematic diagram of alarm input connection is as follows Alarm Input fe Terminals Alarm IN GND switch Input Device Power Supply of Alarm Input Device Schematic Diagram of Alarm Input Normally Opened Connection User s Manual for ZKIR3 Series IR Day amp Night Weatherproof Bullet IPC V1 7 Alarm Input A Terminals Alarm IN GND ach Input Device Power Supply of Alarm Input Device Schematic Diagram of Alarm Input Normally Closed Connection GH When external alarm input is started different alarm inputs have different software settings Please select Normally Opened or Normally Closed on the Web page according to the type of alarm input as detailed in User Manual Using Browser for Video Surveillance 2 The schematic diagram of alarm output default connection is as follows Alarm Output Terminals Alarm COM NO ee Output Device Power Supply of Alarm Output Device Schematic Diagram of Alarm Output Normally Opened Connection OQ notice The connection with normally opened alarm output e g normally opened lock is performed as shown in the following schemati
Download Pdf Manuals
Related Search
Related Contents
HP_1490C_Breadboard_.. Project Design Manual Bewator Entro user's guide Olympus E-300 Quick Start Guide Mode d`emploi Télécharger - Archives de Rennes Instrucciones de montaje y servicio EB 8384 Safety and Installation Manual Flyer Journée Faut-il y croire pour guérir VF Copyright © All rights reserved.