Contents
1. Rate 100Base TX Ethernet IEEE 802 3u Flow Control and Backpressure IEEE 802 3x Transfer Rate 10 Mbps IEEE 802 3 100 Mbps with Auto Negotiation IEEE 802 3u Fault Alarm Fault Alarm Contact Alarm for System Events 1 Relay Output 1A MAX 24 Vdc or 24 Vac Ethernet Port Ri as Network Cabling 10Base T 2 pair UTP STP Cat 3 4 5 6 cable EIA TIA 568 100 ohm 100m 328 100Base TX 2 pair UTP STP Cat 5 6 cable EIA TIA 568 100 ohm 100m 328 Protocols Configuration Protocols Supported Multiple Access Protocol Carrier sense multiple access with collision detection CSMA CD User User Configuration LED Indication Diagnostics LED Indication Power OK Fault Condition Exists Port LED Indication Link Active Full Duplex Collision Compliance EMI and EMC FCC Part 15 Class A CE EN61000 4 2 ESD CE EN61000 4 3 RS CE EN61000 4 4 EFT CE EN61000 4 5 Surge CE EN61000 4 6 CS CE EN61000 4 8 CE EN61000 4 11 CE EN61000 4 12 CE EN61000 6 2 CE EN61000 6 4 Area UL Class Division 2 een oe Ambient Temperature 60 C 6 www cooperbussmann com wirelessresources Rev 1 1 5 Cooper Bussmann 1050E T Unmanaged Ethernet Switch User Manual General 30 mm x 95 mm x 140 mm 1 18 x 3 74 x 5 51 40 C to 75 C 40 F to 167 F Humidity Rating 5 95 RH Non condensing 0 43 kg 0 95 Ib Power Supply Nominal Supply 12 Vdc to 48 Vdc Under Over Voltage Protection and Reverse Polarity Maximum Curr
2. 1 5 Order Information lt 0 na nn nananana ad Nak ae t Chapter 2 GETTING STARTED 8 2 1 Package Contents Hawa KA AA 8 2 2 Hardware Description 8 Front Panel a8 4 tae MEAN GA KAL bene eee 8 TOD WEN ABE nea ai eee ee eed eee ae 8 2 5 WINO woo pa RA ENGAGE bh exe ee ea gress eee 9 Wiring the Power Inpits 9 Wiring the Fault Alarm Contact 9 Ce tael ae AA AA ed a ee 10 2 4 LED Indications Ports and Cabling 10 LED Indicators 2 ix 2 aun at ane bee ee eke a 10 PONS MAA Oe eee ee ee 10 CAD og bu see bate eeu eek ve ee Gas 11 2 5 Mounting Installation aaa kaaa ns ees 11 DIN rail Mounting 000 eee eee 11 Wall Mount Plate Mounting 12 Appendix A GLOSSARY 0200005 13 4 www cooperbussmann com wirelessresources Rev 1 1 5 Cooper Bussmann 1050E T Unmanaged Ethernet Switch User Manual CHAPTER 1 INTRODUCTION The 1050E T Ethernet Switch from Cooper Bussmann is a cost effective solution that meets the high reliability requirements demanded by industrial applications The 1050E T is a 5 port 10 100TX Slim Type Industrial Unmanaged Switch that includes the following features High Speed Transmissions The Industrial Switch includes a switch controller that can automatically sense transmission speeds 10 100Mbps The RJ 45 interface can also be auto detected so MDI or MDIX is automatically selected and a crossover cable is not requi
3. ELPRO Technologies Pi P2 Fault E E 8 ELPRO Technolo gies 1050E T Ethernet Switch o at o o pa x Cooper Bussmann Read and 1050E T Retain for Future Unmanaged Ethernet Switch Reference User Manual Version 1 1 5 COOPER Bussmann Cooper Bussmann 1050E T Unmanaged Ethernet Switch User Manual Interference Issues This Equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC rules These limits are designed to provide reasonable protection against harmful interference in a commercial or industrial installation This equipment generates uses and can radiate radio frequency energy It may cause harmful interference to radio communications if the equipment is not installed and used in accordance with the instructions UL Listed Models When operating at elevated temperature extremes the surface may exceed 75 Celsius For user safety the 1050E T should be installed in a restricted access location The openings on the enclosure are for air convection Protect the equipment from overheating DO NOT COVER THE OPENINGS UL Notice The Equipment shall be powered using an external Listed Power Supply with LPS outputs or a Class 2 Power Supply The 1050E T must be properly grounded for surge protection before use Hazardous Location Notices This equipment is suitable for use in Class Division 2 Groups A B C and D or non hazard
4. Link Active Green CA Connected to network 1 5 Networking is active Off Not connected to network Duplex Collision Ethernet port full duplex 1 5 Flashing Collision of packets occurs Off Ethernet port half duplex or not connect to network 10 www cooperbussmann com wirelessresources Rev 1 1 5 Cooper Bussmann 1050E T Unmanaged Ethernet Switch User Manual The RJ 45 ports Auto MDI MDIX are auto sensing for 10Base T or 100Base TX devices connections Auto MDI MDIX means that you can connect to another switch or workstation without changing straight through or crossover cabling see the following schematics Switch Router or PC Switch Router or PC 3 TD Chao 3 AD 3 TD 3 RD 6 TD _ 6RD 6 TD f 6RD 1 RD 1 TDt 1 RD 1 TD 2 RD 4 2 ID 2 RD 2 TD Straight Through Cable Schematic Crossover Cable Schematic Cabling Use the four twisted pair Category 5 cabling for RJ 45 port connection The cable length between the switch and the link partner switch hub or workstation must be less than 100m 328 ft 2 5 Mounting Installation DIN rail Mounting The 1050E T ships from the factory with the DIN rail mount kit installed Follow these steps to mount the 1050E T 1 Insert the top of DIN rail into the track 2 Lightly push the button of DIN rail into the track Rev 1 1 5 www cooperbussmann com wirelessresources 11 Cooper Bussmann 1050E T Unmanaged Ethernet Switch User Manual T 3 Check
5. US Fax 1 925 924 8502 Online Resources Visit www cooperbussmann com wirelessresources for the following resources and more e User Manuals e Installation Guides e Configuration Software e Datasheets e Dimensional Drawings el mdi 2013 Cooper Bussmann www cooperbussmann com wireless Your Authorized Cooper Bussmann Distributor is North America amp Latin America 5735 W Las Positas Suite 100 Pleasanton California 94588 USA Telephone 1 925 924 8500 elpro sales cooperindustries com Australia New Zealand Cooper Technology Centre Suite 2 01 Quad 2 8 Parkview Drive Sydney Olympic Park NSW 2127 AUSTRALIA Telephone 61 2 8787 2777 elpro sales cooperindustries com China 955 Shengli Road East Area of Zhangjiang High Tech Park Shanghai 201201 CHINA Telephone 86 21 2899 3600 elpro sales cooperindustries com Southeast Asia 2 Serangoon North Avenue 5 06 01 Fu Yu Building 554911 SINGAPORE Telephone 65 6645 9888 elpro sales cooperindustries com ELPRO Technologies The trade names and brand names contained herein are valuable trademarks of Cooper Industries in the U S and other countries You are not permitted to use the Cooper Trademarks without the prior written consent of Cooper Industries COOPER Bussmann www cooperbussmann com wirelessresources
6. ducts and services does not include or infer any transfer of ownership Release Notice This is the May 2013 release of the 1050E T Unmanaged Ethernet Switch User Manual version 1 1 5 2 www cooperbussmann com wirelessresources Rev 1 1 5 Cooper Bussmann 1050E T Unmanaged Ethernet Switch User Manual Follow Instructions Read this entire manual and all other publications pertaining to the work to be performed before installing oper ating or servicing this equipment Practice all plant and safety instructions and precautions Failure to follow the instructions can cause personal injury and or property damage Proper Use Any unauthorized modifications to or use of this equipment outside its specified mechanical electrical or other operating limits may cause personal injury and or property damage including damage to the equipment Any such unauthorized modifications 1 constitute misuse and or negligence within the meaning of the product warranty thereby excluding warranty coverage for any resulting damage and 2 invalidate product certifications or listings Rev 1 1 5 www cooperbussmann com wirelessresources Cooper Bussmann 1050E T Unmanaged Ethernet Switch User Manual CONTENTS Chapter 1 INTRODUCTION 5 1 1 Module Identification 5 1 2 Features and Benefits 6 1 3 General Specifications 6 1 4 Mechanical Specifications 7
7. e fault alarm contact is in the middle of terminal block connector as shown below The contact will be closed for normal operation and will open in the case of a power failure from either of the two power inputs 1 Insert the wires into the fault alarm contact number 3 and 4 ee nA a 1A MAX 24VDC VAC External Load Power Power Fail Alarm Example A NOTE The wire gauge for the terminal block should be in the range between 12 and 24 AWG Rev 1 1 5 www cooperbussmann com wirelessresources 9 Cooper Bussmann 1050E T Unmanaged Ethernet Switch User Manual Grounding To provide maximum surge and lightning protection the 1050E T should be effectively grounded via a GND screw located on the top of the unit next to the terminal connector block All ground earth wiring should be minimum 14 AWG Pi P2 Faut u 8 8 ELPRO Technologies 1050E T Ethernet Switch 2 4 LED Indications Ports and Cabling LED Indicators Three LEDs display the power status and an additional ten LEDs display the network status These LEDs are located on the front panel of the switch and are described in the following table o ooo Desorption OOOO a Green Power input 1 is active Off Power input 1 is inactive Green Power input 2 is active Off Power input 2 is inactive Fault lt _ lt Power input 1 or 2 is inactive pamo Re l0 Power input 1 and 2 are both functional or no power inputs
8. ent 450 mA Draw 1 4 Mechanical Specifications The following diagram shows the exterior dimensions of the 1050E T Ethernet switch 1 5 Order Information Item Product Code Ethernet Switch 1050E T Basic Ethernet Switch Power Supply PS DINAC 24DC OK AC DC Adapter 24 Vdc 2 5 A 60 W 20 to 70 C Rev 1 1 5 www cooperbussmann com wirelessresources 7 Cooper Bussmann 1050E T Unmanaged Ethernet Switch User Manual CHAPTER 2 GET TING STARTED 2 1 Package Contents e 1050E T Ethernet Switch x 1 e Pluggable Terminal Block x 1 e Wall Mounting Plate x 2 2 2 Hardware Description Front Panel The front panel of the 5 port 10 100BaseTX Industrial Switch is shown below LED Indicator RJ 45 Port Top View The top panel of the 5 port 10 100BaseTX Industrial Switch is equipped with one terminal block connector of two power inputs Terminal Block 8 www cooperbussmann com wirelessresources Rev 1 1 5 Cooper Bussmann 1050E T Unmanaged Ethernet Switch User Manual 2 3 Wiring Wiring the Power Inputs Follow these steps to insert the power wire 1 Insert the positive and negative wires into the V and V contacts on the terminal block connector 2 When using a single power supply to power the device connect the power supply to both power inputs to ensure that the fault alarm is not set Connect V to both pins 2 and 6 and then connect V to both pins 1 and 5 V V v Y Wiring the Fault Alarm Contact Th
9. k device transmits data after detecting that a channel is available However if two devices transmit data simultaneously the sending devices detect a collision and retransmit after a random time delay A DIN rail is a metal rail of a standard type widely used for mounting circuit breakers and industrial control equipment inside equipment racks Electrostatic discharge ESD is discharge of static electricity from a outside source such as human hands into an integrated circuit often resulting in damage to the circuit The Federal Communications Commission FCC is the US agency that regulates interstate and international wire radio and other broadcast trasmissions including telephone telegraph and telecommunications A full duplex or double duplex system allows communication in both directions and unlike half duplex allows this to happen simultaneously Land line telephone networks are exam ples of full duplex since they allow both callers to speak and be heard at the same time Institute of Electrical and Electronics Engineers New York www ieee org A membership organization that includes engineers scientists and students in electronics and allied fields It has more than 300 000 members and is involved with setting standards for computers and communications Medium Dependent Interface MDI describes the interface both physical and electrical in a computer network from a physical layer implementation to the physical medium u
10. mperature range power range serial number and all certifications PERRO AE Bussmann C Ut LISTED L T E E344221 SL Class Div 2 Group ABCD Temp T5 Ta 40C to 60C 450 mA 12 48V MODEL EL 1050E T A YUU VOM TY RN FC bad S N l 09121405000 N16 This device is in compliance with part 15 of the FCC rules Operation is subject to the following two conditions a 1 This device may not cause harmful www cooperbussmann com wireless interference 2 This device must accept any inteference received including inteference that may cause Manufactured in Taiwan uridesired operation Rev 1 1 5 www cooperbussmann com wirelessresources 5 Cooper Bussmann 1050E T Unmanaged Ethernet Switch User Manual 1 2 Features and Benefits IEEE 802 3 10Base T 802 3u 100Base TX e Flow control on full duplex e RJ 45 connectors with auto MDI MDIX functionality e Store and forward switching architecture e Relay alarm contact for system events e UL Class Division Il for Group A B C and D hazardous locations e Supports surge protection 3 000 Vdc for power line e Supports 6 000 Vdc Ethernet ESD protection e Supports redundant 12 Vdc to 48 Vdc power input e Provides flexible mounting DIN rail Wall Mounting e Supports operating temperatures from 40 C to 75 C 1 3 General Specifications Product specifications are subject to change without notice Ethernet Standards Transfer Standards 10Base T Ethernet IEEE 802 3
11. ous locations only For Hazardous Locations operating temperature is strictly 40 C to 60 C only WARNING EXPLOSION HAZARD Do not disconnect equipment unless power has been removed or the area is known to be non hazardous WARNING EXPLOSION HAZARD Substitution of any components may impair suitability for Class Division 2 WARNING EXPLOSION HAZARD The area must be known to be non hazardous before servicing replacing the unit and before installing WARNING Exposure to some chemicals may degrade the sealing properties of materials used in the Sealed Relay Device Recommendations It is recommended to inspect the sealed relay device periodically and to check for any degradation of the materials and to replace the complete product not the sealed device if any degradation is found Important Notice Cooper Bussmann reserves the right to modify the equipment its specification or this manual without prior notice in the interest of improving performance reliability or servicing At the time of publication all data is correct for the operation of the equipment at the voltage and or temperature referred to Performance data indicates typical values related to the particular product No part of this documentation or information supplied may be divulged to any third party without the express written consent of Cooper Bussmann Products offered may contain software which is proprietary to Cooper Bussmann The offer or supply of these pro
12. red All Ethernet ports have memory buffers that support the store and forward mechanism This assures that data is properly transmitted Dual Power Input To reduce the risk of power failure the Industrial Switch provides 12 Vdc to 48 Vdc dual power inputs If there is power failure Industrial Switch will automatically switch to the secondary power input Flexible Mounting The Industrial Switch is extremely compact and can be mounted on a DIN rail or a wall so it is suitable for any space constrained environment Advanced Protection The power line of the 1050E T supports up to 3 000 Vdc EFT Electrical Fast Transient protection which secures equipment against unregulated voltage and makes systems safer and more reliable Its 6 000 V ESD protection for Ethernet ports makes the 1050E T suitable for harsh environments Wide Operating Temperature The operating temperature of the 1050E T is between 40 C and 75 C Given this wide range you can use the Industrial Switch in some of the harshest industrial environments Easy Troubleshooting LED indicators make troubleshooting quick and easy Each 10 100 Base TX port has 2 LEDs that display the link status transmission speed and collision status Also the three power indicators P1 P2 and Fault help you diagnose problems immediately 1 1 Module Identification The module identification label can be found on the bottom of your 1050E T device This label contains the model number te
13. sed to carry the transmission Ethernet over twisted pair also defines a medium dependent interface crossover MDIX interface Auto MDIX ports on newer network interfaces detect if the con nection would require a crossover and automatically chooses the MDI or MDIX configuration to properly match the other end of the link Standard connectors used in Ethernet networks RJ 45 connectors are similar to standard RJ 11 telephone connectors except that RJ 45 connectors can have up to eight wires whereas telephone connectors have four wires A type of hub that efficiently controls the way multiple devices use the same network so that each can operate at optimal performance A switch acts as a networks traffic cop Rather than transmitting all the packets it receives to all ports as a hub does a switch transmits packets to only the receiving port Underwriter Laboratories UL is one of several companies approved to perform safety testing by the US federal agency Occupational Safety and Health Administration OSHA www cooperbussmann com wirelessresources 3 Cooper Bussmann 1050E T Unmanaged Ethernet Switch User Manual Notes 14 www cooperbussmann com wirelessresources Rev 1 1 5 Rev 1 1 5 Customer Assistance Technical Support United States 1 866 713 4409 Australasia 61 7 3352 8624 Other 1 604 944 9247 Email ELPRO Support cooperindustries com Website www cooperbussmann com wireless Australasia Fax 61 7 33528677
14. the module is firmly secured to the DIN rail track To remove the Industrial Switch from the track reverse steps above Wall Mount Plate Mounting Follow these steps to mount the switch using the wall mount plate Unscrew the screws to remove the DIN rail mount from the switch 1 Fit the wall mount plates to the top and bottom ends of the switch 2 Use the mounting screws to secure the wall mount plate to the switch 3 Mount using the wall mount holes provided To remove the wall mount plate reverse the steps above 12 www cooperbussmann com wirelessresources Rev 1 1 5 Cooper Bussmann 1050E T Unmanaged Ethernet Switch User Manual APPENDIX A GLOSSARY 100Base TX 10Base T CSMA CD Full Duplex MDI MDIX RJ 45 Switch Rev 1 1 5 100Base TX is a Fast Ethernet cabling standard 100Base TX devices can transfer data at a rate of up to 100 Mbps and use two wire pairs of wires inside a category 5 or above cable 10Base T is an Ethernet cabling standard 10Base T devices can transfer data at a rate of up to 10 Mbps and use twisted pairs of wires in their Ethernet cabling American wire gauge AWG also known as the Brown amp Sharpe wire gauge is a standard ized wire gauge system used predominantly in the United States and Canada for the diameters of round solid nonferrous electrically conducting wire Carrier Sense Multiple Access Collision Detection is the access method used on an Ethernet network A networ