Home

Shenzhen Legend Beauty Beauty Equipment Co., Ltd.

image

Contents

1. Tattoo Removal Laser System User s Manual E 30 Power 400W Voltage 220 240V 50hZ 110 130 60Hz Packing size 64 49 49cm Page 1 Shenzhen Legend Beauty Beauty Equipment Co Ltd CONTENT 1 Important Notice 2 Technical Specifications 3 Product Features 4 Working Principle 5 Operations Guidance 6 Operation skills for laser tattoo removal system 7 Requirement before treatment 8 Before amp After treatment by laser 9 Maintenance 10 Common Questions and Fixing 11 Special Illustration CAUTION Page 2 Shenzhen Legend Beauty Beauty Equipment Co Ltd 1 When you received the new machine please open it work one minute enjoin from the machine working Soy shut down the machine Affusion water again Anew Open the machine When the water stream very well then you can let the machine working 1 Important Notice 1 Firstly check the circuitry connecting correctly or not before using the machine 2 Before starting work fill up the water tank with distilled water from the Affusion Orifice 3 Water must be distilled water or ion wipe off not the mineral water or tap water 4 Before using the machine infuse the distilled water overflow the overflow Orifice Prohibit to work without water Otherwise if shatter the laser head the user bear it o N nN purity Avoid irradiation to eyes directly Forbid disassembling without manufacture permission Put the head light on fixture av
2. anything abnormally please cure it early 8 Pigment fadeaway is a slow process for the pigmentation skin normally it is 1 3 months In order to get more favorable effect repeated treatment should be 1 3 months interval 9 Maintenance 1 Notice to use purified water or de ionized water not the mineral water or tap water 2 Be careful not to irradiate the machine avoiding the surface of machine injured 10 Common Questions and Fixing Page 8 Shenzhen Legend Beauty Beauty Equipment Co Ltd 1 No signal after power on The reason is that the power plug doesn t reach it please directly connect the power plug 2 No signal after power on because of the fuse blowing Please replace the fuse with 5A 110V AC 3 No signal on the screen because that the Crash stop switch being pressed Please lift the Emergency stop switch up 4 Touch off light is off state pressing the button on the screen when the machine is on pre ignition One reason is that the Xenon Lamp is damaged need to replace a new one Another reason is that the life time for Xenon is full change a new one 5 Water leaking out of machine because of the impact during on shipment process May in the tube joint Please call the service people to deal with it 6 If you feel the energy is not big enough or the curing treatment is not well enough the reason maybe the temperature is too higher or no water in the machine and damaged the body machine Please stop firs
3. art shows pink 2 3 weeks later it appears coffee color and 1 2 months later recover Page 7 Shenzhen Legend Beauty Beauty Equipment Co Ltd 3 Care after treatment 1 You may clean the skin with non stimulator water after treatment 2 If there is slight bleeding when adjust the Volt higher please wipe off and smear the Antiphlogistin such as Illotycin until the scar drops off Not cosmetic or other medicines 3 If the treatment parts is flush and feeling it not comfortable can do ice compress 4 Before the scab dropping off the treatment part must be care not to touch water not being scratching avoiding certain food of hot dark color of coffee Coco Cola etc Prohibit smoking and drinking Let the scabs desquamate naturally not scale off in a force 5 Not taking plenty of sports avoiding of sweat infection 6 After the scab desquamating No need to coat the Illotycin Erythromycin again just smear the suntan lotion SPF15 upwards even in the room preventing UVA UVB and keep along 3 to 6 months because of the treatment skin sensitivity to the sunlight Using suntan lotion or umbrella preventing can improve the effect early 7 Period for laser treatment According to the different treatment parts and pigment dark or not the treatment may be several times Normally one period of treatment is 1 2 times every time at 20 30 days interval If there is no special every 2 4 weeks go to clinic check again if there is
4. d red mark 6 Operation skills for laser tattoo removal system 7 Requirement before treatment 1 Beautician should make record for customers fully understanding customers skin condition and chose the right laser mirror at the same time communicate with your customer freely to let she or he feel relax 2 Clear treating part skin and wait until it is totally dry and sterilize every apparatus 3 Energy reference Page 6 Shenzhen Legend Beauty Beauty Equipment Co Ltd Notice A 1064nm round mirror for blue and black colors B 532nm square mirror for red and brown color 8 Before amp after treatment by laser 1 Preparation before treatment by 1 2 3 4 5 No inflammation in the treatment part No treatment for pregnant woman Fomentation on the treatment part avoid skin dehydration No cosmetic left clean the treatment part Taking photo before treatment compare the effect after operation 2 Skin appearance after treatment 1 2 Reddish swelling on treatment part on the moment it will disappear shortly To some special customers need to be higher when you make the Volt too high there comes the scab but it will drop off naturally after 7 days not to scratch it skin becomes normally about 2 days Taking some Vitamins can lighten the pigment circumfluence Usually there is a feeling of scorching or slight bleeding it is normal and no scar When the scabs fade away the treatment p
5. oid broken after operation Change cooling water every month Long or short the time according to the water 9 Start up the machine after one minute later for the water circulation completely 10 Ensure the machine well grounded 2 Technical Specifications laser type Q Switched ND YAG laser Page 3 Shenzhen Legend Beauty Beauty Equipment Co Ltd wavelength 1064nm amp 532nm cooling system wind closed water circulation cooling Display 6 0 screen Output power 400W pulse energy 1 1500 1 30 frequency 1 5HZ eletrical requirements 100 110V 50 60Hz 230 260V 50 60Hz dimension L W H 50 38 29 cm machine net weight 16KG packing size 64 49 49cm Gross weight 32KG Application Range 6 Remove the black amp blue pigment on eyebrow eye line and lip line Scour off tattoo freckle lentigines old aged marks vascular expansion and type of blood vessel lesions etc 7 No harm to the follicles and normal skin leaving no scar only to lustrate pigment 8 To remove melanin not being eliminated by medicament and other means 9 Be in no need of anesthesia and quick recovery No negative influence 3 Product Features 3 Improve the efficiency and make the best solutions for no burning on the hand piece at all 4 Long lifetime for Xenon Lamp which is with the imported US technology 5 More stability with the hand piece structure inside improved 6 Add the infra
6. red Guide light to aim the target tissue correctly 5 Portable design and easy operation can do the touring treatment lower cost and wider usage can make quick return of investment 4 Working Principle Laser emitted by the system has a strong penetration ability which allows it to reach the deep layer of dermis The pigment particles absorb the light energy and explode sharply burst into the tiny pieces thus diminish the color density and get rid of it So the appliance can effectively do away with mutant pigmentations and vascular tissue based on undamaged ambient tissue This is called Selective heat absorption principle Page 4 Shenzhen Legend Beauty Beauty Equipment Co Ltd in medical field Items times interval notice hai tect ehe 12 30 60day Remove eyebrow hair and protec eyeballs eyelid 13 45 60day Remove eyebrow hair and protect eyeballs lips outline 1 3 15 45day use 532mn mirror Body tattoo 1 4 30 60day Exude blood is effective flecks aged spot 1 5 15 30day Exude blood is effective birth mark 3 7 45 90day Exude blood is effective 5 Operations Guidance Page 5 Shenzhen Legend Beauty Beauty Equipment Co Ltd 3 Treatment interface 2 Oo ND YAG LASER functions 1 1064nm Wavelength Remove black and dark blue tattoo pigments such as tattoos eyebrows dark color around the eyes freckle age spot etc 2 532nm Wavelength Remove red and brown tattoos an
7. tly after half an hour starting the machine again 11 Special Illustration 1 Illustration of rear panel Affusion Hole Overflow Hole Drain Hole 2 Press the plastic circle at the affusion hole when inserting or pulling out the affusion funnel 3 Attention there is a little rubber stuff in the drain hole Don t lose it or it may leak Page 9 Shenzhen Legend Beauty Beauty Equipment Co Ltd water Page 10

Download Pdf Manuals

image

Related Search

Related Contents

Benutzer-Handbuch MASS-STREAM D-6300  1MB  Installation Manual  Grille d`évaluation CCF U33    Hamilton Beach Tango Series User's Manual  シラバス目次 - 東洋食品工業短期大学  MANUEL D`UTILISATION  Blackstar Amplification HT-1RH  Hitachi Projector CP-X935E User's Manual  

Copyright © All rights reserved.
Failed to retrieve file