Table of Contents The Multifunction Timegrapher No
Contents
1. 7 8 2 THE INSTRUMENT CAN ENTER TESTING STATE WITH THE SOUND OF D1 BUT AFTER PLACED THE WATCH ON THE SENSOR THE INSTRUMENT DO NOT 7 8 3 SIGNAL LED 15 BRIGHT BUT THE LINES IS SCATTERED OR OCCUR MANY LINES 7 1 2 Instrument function The Multifunction Timegrapher N 0 1000 is a precise mechanical watches test instrument it is used for multi testing by watch manufacturers and watch technician The frequency diagram of the watch can be displayed in the LCD screen According to different watches the instrument will automatically adjust optimal signal level during testing The instrument will automatically calculate the rate amplitude beat error and display them by data in real time For the conventional beat the instrument can automatically response for the special beat can manually select The sampling period can selected by 2 seconds 4 seconds 6 seconds 8 seconds 12 seconds 20 seconds 30 seconds 60 seconds the average of corresponding period will be regard as the precise value of the watch Six kinds of testing position can be adjusted and the simulation sound can be play in the speaker or gute Keys and Display 2 1 Key Function D RATE AMPL I TUDE BEAT ERROR PARAMETERS Q 22800 Aa No 1000 5 sig O value JN B start stop A MULT I GUNCT
2. No 1000 User Manual Table of Contents 1 INSTRUMENT 1 252 KEYS AND DISPLAY 1 2 1 KEC FINGIN eee GS bok feed Geeta tea ee os 1 2 2 PARAMETERS AND 5 2 259 CONNECTION th mei etal Abdo Ci we A Sod ae 3 3 INSTALLATION aa 3 3 1 THE BASIC EQUIPMENT 5 3 3 2 EQUIPMENT INSTALLATION 0 0c ee eee eee ee eee eee eee ee d Y 3 3 2 1 Power 7 2 2 2 3 3 2 2 Microphone 2 2 24 2 4 4 OPERATION 4 8 F aw oe ROLE Ae wee 4 THe USE DF MEW AL ee eee 4 J STAR PAUSE 4 5 2 MENU SPEAKER 4 REV ges sats ool 4 5 4 VALUE KEY t 5 PARAMETERS bcc ep ee 5 6 1 BEAT NUMBERS FREQUENCY NUMBERS 5 625 WER ANGLE hat ttc a saa ee in at Sioa 5 62522 PER VOD dase aS 6 7 TECHNICAL ae ware eb ON ae ees 6 8 COMMON FAULTS AND HANDLING 7 8 1 AFTER INSERT THE SOCKET THE SCREEN IS
3. adjustment press the Value Key can select 4 next lower parameter 5 4 Value Key Press the Value Key f can increase the LCD s contrast when the instrument running After pressed the Menu Key to select the adjustment press the Value Key t can select the next higher parameter 6 Parameters 6 1 Beat Numbers Frequency Numbers The following beat numbers are selected by automatic selection mode 12000 14400 18000 19800 21600 25200 28800 36000 43200 If the tested beat is not in automatically selection theanstrument will display the closest beat number but the test result is not correct At this time use the manual mode to select the relative beat Manual selection can selected out the beat number that Automatic select can not identify and rare beat number The following beat are selected by Manual selection mode 3600 6000 7200 7380 7440 7800 9000 9100 10800 11880 12000 12342 12480 12600 13320 13440 13500 14000 14040 14160 14200 14280 14400 14520 14580 14760 14850 15000 15360 15600 16200 16320 16800 17196 17258 17280 17786 17897 18000 18049 18514 19332 19440 19800 20160 20222 20944 21000 21031 21306 21600 25200 28800 32400 36000 43200 6 2 Lift Angle The lift angle is 52 for many common movements therefore the lift angle value of instrument for factory is set to 52 This value is required to calculate the amplitude and must be selected accordin
4. ION j Start Stop Key The key used for start stop to test the watch B Menu Speaker Key Selection of adjustment item or turn on off speaker C Value Key Selection of the next lower value or adjustment of dips contrast D Value t Key Selection of the next higher value or adjustment of dips contrast 2 2 Parameters and Display A RATE Rate deviation in seconds per day B AMPLITUDE Display of the amplitude in degrees C BEAT ERROR Display of the beat error in ms D PATAMENTS Display of the lift angle or the beat switching by 5s 2 3 Connection Frequency Microphone Calibration A Frequency calibration Connector Only the company s engineers can calibrate the frequency B Sensor Connector C Power Switch 3 Installation 3 1 The BasicyEquipment Components Testing equipment host Microphone Power cable User Manual 3 2 Equipment Installation The instrument is to be installed in such a way that it is not exposed to direct sunlight or to extreme temperature of 60 C The microphone should be placed at a sufficient distance from noisy machines loudspeakers sharp stroke sound and particularly from ultrasonic cleaning machines The high noise will disturb signal sensing by the microphone 3 2 1 Power Supply Insert Power Cable into the mach outlet Power supply voltage
5. g to the watch movement The lift angle can be set to between 30 and 70 6 3 Period The measuring period selectable 25 45 85 125 205 305 60s Use to recalculate the average values of the test result 7 Technical Data Measuring possibilities Rate deviation amplitude beat error of mechanical watches and diagram recording of the beat noise Frequency numbers It can selected out the common beat number automaticly also selected out the less common beat number by manual Rate deviation measurement the range of deviation is 999 sec day 150 sec day Amplitude measurement Numerical display in degrees resolution is 1 measuring range 100 to 360 the lift angle can affect the amplitude range 30 to 70 Under normal circumstances the amplitude value do not exceed 360 Measuring period times for the average numerical results 2s 4s 8s 10s 20s 30s 30s 60s Measuring of the Beat error Frequency error Numerical display in milliseconds Resolution is 0 1 milliseconds the measuring range is 0 9 9 ms Lift Angle the measuring range is 30 to 70 the factory set it to 52 Supply voltage single phase 100 V 240V 10 two line Measure positions to 6 positions Use of the environment 0 to 50 relative humidity 0 to 80 RH Shell Light grey plastic Dimensions 173 9 5 11 5mm Weight 4026 8 Common faults and handling 8 1 After in
6. is between the 100 V 240V 3 2 2 Microphone Connection The sensor plugs to connect to the host interface Department of sensors 4 Operation After connecting of the power and the sensor the instrument will be testing status Place the watch on the signal sensor and the uplift of watch leader should the sheet metal Test position can be changed freely the hand must remove from the sensor after the test position is fixed Green light flashing means have received the signal of watch 5 The Use of Keys 5 1 Start Pause Key Please press the Start Pause Key before adjuStiig any parameters of theanstrument First press the Start Pause Key one time the instrument pause The parameters can be changed when green LEDyis off and LED is on After adjustment rightly press the Start Pause Key again when green LED is on and red LED is off The instrument will be carried out the normal test and refresh the data and the screen to return to running condition 5 2 Menu Speaker Key When the instrument running press directly the Menu Speaker Key can turn on or off the speaker When the instrument pausing press the Menu Speaker Key can enter the Menu window then press the Menu Speaker Key can select the menu item press the Value Key ftor can change the selected items parameters 5 3 Value Key Press the Value Key can decrease the LCD s contrast when the instrument running After pressed the Menu Key to select the
7. sert the socket the screen is dark Check the power pilot LED is bright or not 8 2 The instrument can enter testing state with the sound of Di but after placed the watch on the sensor the instrument do not work Check the second hand whether rotation and amplitude must be more than 100 the crown of watch leading is against at the sheet metal of sensor 8 3 Signal LED is bright sbut the lines is scattered or occur many lines Maybe thebeat is mistake adjusted the right beat frequency by manual selection