Home
TULOX 200_EN.indd - Steinbach & Vollmann GmbH & Co KG
Contents
1. oO Steinbach amp Vollmann GmbH amp Co KG 42579 Heiligenhaus Instruction Manual TULOX 200 The lock will now check your entry The display will show one of the following messages e Activate user OK Function was executed without problems e Error Master code Entered master code not OK e Error Already in use A code is already enabled for the user ID e Error The user number is not possible with this lock User On Off All normal users are switched ON or OFF If the user codes are switched OFF the lock can be opened with the master code only Note e This function can only be carried out by the master user tart men Menu k Sta enu glen KEY Change U code lt 1 2 OK 3 gt Select menu option or User on off User On Off lt i 2 OK 3 gt Confirm selection User on off lt i 2 OK 3 gt Enter Master code Enter Master code 00000000 The lock will now check your entry Please wait Check input 60 User on off OK User On Off The lock will now check your entry The display will show one of the following messages e User On Off OK Function was executed without problems e Error Master code Entered master code not OK depending on flash version Steinbach amp Vollmann GmbH amp Co KG 42579 Heiligenhaus 35 A Delete User This fun
2. Check keypad N H w V Check keypad 1 press Press key 1 Press keys 2 8 9 O O O Lock confirms Check keypad User Information Check keypad 2 press Check keypad D O O N Bs The function gives you an overview of the status of each user whether they are deleted or if the code is in use Note e This function can only be carried out by the master user Start menu Menu key Change U code el 2 OK 3 gt Select menu option or 6 User info User info lt 1 2 OK u Confirm selection User info lt 1 2 OK 3 gt Enter master code 000090000 Enter Master code Steinbach amp Vollmann GmbH amp Co KG 42579 Heiligenhaus 37 Instruction Manual TULOX 200 Processing of information re Check input 60 Select user number Example User 01 Already in use Select additional user Example User 02 Deleted ven The information in the display have the following meanings e Already in use A code has already been enabled for the user number and is used e Deleted The user number is still free and another code may be activated e Not available The use of the user ID is not possible with this lock Setting the Time Delay Values Setting the delay Delay Code entry Start of time delay 01 to 99 minutes 2
3. n Enter the current code 0A000000 Enter the new code OKOLOLOLOLOLOLO Enter the new code again OOO OB OO The lock will now check your entry Lock confirms Change U Code The lock will now check your entry The display will show one of the following messages Change U code lt l 2 OK 3 gt Change U code a1 2 OK 377 Current code Enter New code Enter New code Enter again Please wait Check input 60 Change U code OK e Change U code OK Function was executed without problems e Error New code The first and second input of the new code are not equal e Error Current or new code not OK note instructions above 32 Steinbach amp Vollmann GmbH amp Co KG 42579 Heiligenhaus Instruction Manual TULOX 200 Change Master Code Note e The code must be 8 digits long e Do not use any personal or easy to guess data for your code such as birthdays e Simple codes that are easy to guess may not be used Avoid to record the selected code or save to disk Should that for various reasons can not be avoid so the recorded code is to be kept safe and to be protected against unauthorized access by third parties e For security reasons you should change the code only when the safe is open Before closing the door check the correct functioning of the new codes e New codes are rejecte
4. Forgot User Code If a user has forgotten his code Forgot Master Code If a master has forgotten his code Message Display No display The display is in error blocked message No key tone Mechanically Blocked mechanics Delete user see Delete Delete user User 2 OK Please notify customer service Change batteries The keyboard is not attached properly Remove the cover with a light force remove the bat teries and insert them again see Changing batteries The keyboard is not attached properly Check the keyboard see Check Keypad incorrect code entered Cover removed The keyboard is not attached properly If you have entered a correct code and the lock does not open yet please check if the knob is rotated 180 Steinbach amp Vollmann GmbH amp Co KG 42579 Heiligenhaus STUV Steinbach amp Vollmann GmbH amp Co KG Schlo und Beschl gefabrik Parkstra e 11 42579 Heiligenhaus Germany Phone 49 2056 14 0 Fax 49 2056 14 251 Email info stuv de Internet www stuv de 60020148 03 2015 Printed in Germany Permissible variations in models and Colors as well as changes to adapt to the latest technology and produc tion are expressly reserved
5. KG 42579 Heiligenhaus 27 PN Instruction Manual TULOX 200 Configuring the Language You can select various languages Note e After interrupting the power supply for a purpose such as changing the batteries this procedure has to be repeated Menu k Start menu Menu key E eae lt 1 2 OK Ir Select menu option or Mi Language Language lt 1 2 OK E Confirm selection Language lt 1 2 OK iS aed lect lan Select language or English zei 2 OK 3 gt ee Configuring Display Brightness You can change the display s brightness as needed Note e The standard value is 10 e 0 will turn off the display s illumination The display will still be easily readable This configuration is recommended to increase battery life e The brighter the display is set the lower the battery life tart men Menu k Sta eile ee ey Change U code lt 1 2 OK 3 gt Select menu option or f p Brightness Brightness lt i 2 OK 3 gt Confirm selection 103 O lt 1 2 OK 3 gt Select brightness or Zu lt 1 2 OK 3 gt enum 28 Steinbach amp Vollmann GmbH amp Co KG 42579 Heiligenhaus Instruction Manual TULOX 200 Timeout Time before the screen turns off automatically if no operations are performed The timeout can be set from 4 up to 10 seconds en k Se
6. Time delay OK The lock will now check your entry The display will show one of the following messages e Time delay OK Function was executed without problems e Error Master code Entered master code not OK e Error Time delay Entered time not OK Changing the Time Delay Values possible during the opening window only Note e Switching off the function can only be performed during the opening window after elapse of delay time e After switching off the function code entry is possible to open the lock e When new times are set during the opening window they will be taken over after the elapse of opening window 13 Start menu Menu key ar Bede lt 1 2 OK 3 gt Select menu option or 7 Time delay Time delay lt 1 2 OK 3 gt Confirm selection Time delay lt 1 2 OK 3 gt Steinbach amp Vollmann GmbH amp Co KG 42579 Heiligenhaus 39 Instruction Manual TULOX 200 Enter Master code Enter master code 00000000 Delay time Doe ey e switch off 00 00 99 gt M min Please wait Check input O oO o Lock confirms 1 Time delay deleted Dee Deleted The lock will now check your entry The lock will now check your entry The display will show one o
7. lt l 2 OK 3 gt Enter Master code Please wait Check input 60 Auditor on OK 45 Feu Auditor Off via Display ia gt Select menu option Auditor configuration Select menu option Auditor off Enter master code 0A000000 The lock will now check your entry Lock confirms Auditor off Reset Auditor via Display Start menu Select menu option Auditor configuration Confirm selection Select menu point Reset auditor Confirm selection Enter master code The lock will now check your entry Lock confirms Reset auditor 46 Menu key Instruction Manual TULOX 200 Change U code sel 2 OK 3 gt Auditor config lt 2 OK 3 gt Auditor config lt 1 2 OK 3 gt Auditor off lt 1 2 OK 3 gt Auditor off lt l 2 OK 3 gt Enter Master code Please wait Check input 60 Auditor off OK Change U code lt 1 2 OK 3 gt Auditor config x 1 2 OK Sr Auditor config lt 4 OK a gt Reset auditor lt l1 2 OK 3 gt Reset auditor lt 1 2 OK 3 gt Enter Master code Please wait Check input 60 I Reset auditor OK Steinbach amp Vollmann GmbH
8. mode Pressing any key will wake the system The display will show the following screen SLUY TULOX View of display General Information on Operation Menu An incorrect entered number can be deleted with the C key In order to the menu options you can navigate through the menu To do so press the menu key The first menu option offered is Change U Code You can use keys 1 and 3 to move through the menu and select various menu options You may confirm your selection using the 2 key The menu is set up as follows Change U Code s 2 OR e View of display Change U code lt gt Activate user lt gt User on off lt gt te user lt gt User info Language lt gt Reset lt gt Setting clock lt gt Brightness lt gt Check keypad lt gt Time delay Note e The menu function selected will be shown on the top line of the display for 5 seconds e f there is a black cursor flashing on the screen then the system is waiting for your entry Steinbach amp Vollmann GmbH amp Co KG 42579 Heiligenhaus 07 Instruction Manual TULOX 200 Changing the Batteries To insert or change new batteries pull away the cover with a light Remove cover Replace cover force The cover is held in place with magnets Ensure the keys are lined up before allowing the magnet to pull the cover into position Insert the new bat
9. 200 A 1 Master up to 8 User Time Delay Quick Opening Code e Changing Code Master and User Code e Activate User e User On Off e Delete User e Check Keypad e User Information e Reset e Time Delay e Overriding Time Delay Dual mode 1 Master up to 97 User Time Delay Silent Alarm Logging of all Events Time Control e Changing Code Master and User Code e Activate User e Delete User e Check Keypad e User Information e Reset e Silent Alarm e Time Delay e Log Auditor e Auditor Configuration e Loading Time Control 1 Master up to 97 User Time Delay Quick Opening Code Silent Alarm Logging of all Events Time Control e Changing Code Master and User Code e Activate User e User On Off e Delete User e Check Keypad e User Information e Reset e Silent Alarm e Time Delay e Overriding Time Delay e Log Auditor e Auditor Configuration e Loading Time Control Steinbach amp Vollmann GmbH amp Co KG 42579 Heiligenhaus 05 ENGLISH 06 Steinbach amp Vollmann GmbH amp Co KG 42579 Heiligenhaus Instruction Manual TULOX 200 Instruction Manual TULOX 200 Flash 1 to 5 For information about the installation of the lock please refer to the separate installation manual The TULOX electronic safe lock system is equipped with advanced power management features After a few seconds without operation the system turns off the display and starts the power saving
10. a purpose such as changing batteries this procedure has to be repeated Select menu option Language Confirm selection Confirm selection Select language Steinbach amp Vollmann GmbH amp Co KG 42579 Heiligenhaus Change U code lt a Language oe 2 OK 3 gt English lt 1 2 OK 3 gt Deutsch lt 1 2 OK 3 gt I Q co 1 a Instruction Manual TULOX 200 Configuring Display Brightness You can change the display s brightness as needed Note e The standard value is 10 e 0 will turn off the display s illumination The display will still be easily readable This configuration is recommended to increase battery life e The brighter the display is set the lower the battery life lt 1 2 OK Ja lt 1 2 OK a gt lt 1 2 OK 3 gt l 2 OK an Timeout Time before the screen turns off automatically if no operations are performed The timeout can be set from 4 up to 10 seconds tart men Menu k an un IN Change U code lt 1 2 OK ger Select menu option Timeout or Timeout lt 1 2 OK 3 gt Confirm selection Timeout lt 1 2 OK 3 gt Enter Example eee 04 10 sec 00x oons Timeout DE Timeout O i The lock will now check your entry The display will show one of the fol
11. digits Sets the function This time has to elapse before the lock can be opened Time delay Opening window Code entry within the opening window Opening window p g opens the lock 01 to 19 minutes 2 digits Within this period the code must be entered again to open the lock Note e This function can only be carried out by the master user e A shorter opening delay time must be entered within the opening window after the opening time delay e f the function is selected before or during the opening delay time the opening delay time can only be extended Shorter times are not accepted e After changing the times the opening window will continue Code entry for opening is possible e Only with Flash 7 two codes can be entered in the opening window See opening according to the dual mode identification 38 Steinbach amp Vollmann GmbH amp Co KG 42579 Heiligenhaus Instruction Manual TULOX 200 tart men Menu ke Sta un y Change U code lt 1 2 OK 3 gt Select menu option or a Time delay Time delay lt 1 2 OK 3 3 Confirm selection Time delay lt 1 2 OK 3 gt Enter master code SOBEOOBO8O nate Master code ning delay tim arer Ope g de ay 9 Time delay value e 20 minutes Example 00 99 gt W min Enter Opening window Opening window e 6 minutes Example 01 19 gt F min The lock will now check your E lea Wale Check input entry 60 Lock confirms a 5 Time delay
12. ries then 4 pieces 1 5V Alkaline AA Mignon LR6 Battery empty Second step At this stage the supply voltage has reached a critical value therefore an opening can not be exe cuted After entering the code Battery empty is displayed and the lock will not open Tamper Evidence Note After snapping the cover back on the display will show the mes sage Cover removed for a short time This will be showed re Cover removed peatedly until a valid code has been entered If you see this message without having removed the cover then check the keypad for potential tamper evidence Steinbach amp Vollmann GmbH amp Co KG 42579 Heiligenhaus 13 PN Instruction Manual TULOX 200 Change User Code Master Code and User Code Note e The code must be 6 digits long e Do not use any personal or easy to guess data for your code such as birthdays e Simple codes that are easy to guess may not be used Avoid to record the selected code or save to disk Should that for various reasons can not be avoid so the recorded code is to be kept safe and to be protected against unauthorized access by third parties e For security reasons you should change the code only when the safe is open Before closing the door check the correct functioning of the new codes e New codes are rejected if the code is only one digit different from existing code the code is identical to the code of a disabled use
13. the opening window they will be taken over after the elapse of opening window Select menu option Time Delay Confirm selection Steinbach amp Vollmann GmbH amp Co KG 42579 Heiligenhaus 20 Menu key GE Change U code lt 1 2 OK 3 Time delay lt 1 2 OK 3 gt Time delay lt 2 OK 3 gt Instruction Manual TULOX 200 Enter Master code Enter master code DOO OO Delay time r an e switch off 00 00 99 an Enin The lock will now check your entry Lock confirms Time Delay deleted The lock will now check your entry The display will show one of the following messages Please wait Check input O oO o Time delay Deleted e Time delay Deleted Function was executed without problems e Error Master code Entered master code not OK e Error Turning off the function can only be performed within the opening window Opening when Time Delay is Active Note e Entering an invalid code in the menu within the opening delay time will cancel the entire procedure e Only with Flash 4 two codes can be entered in the opening window see opening according to the dual mode identification Bu Code The lock will now check your Please wait Check input entry 60 ames nn Check input Ac
14. 1 2 OK 3 gt Delete user lt 1 2 OK 3 gt Delete user lt 1 2 OK 3 gt Enter Master code Enter User ID Please wait Check input 60 Delete user OK Function was executed without problems maximum number of users depending on flash version with Flash 2 selection of user number is not possible Steinbach amp Vollmann GmbH amp Co KG 42579 Heiligenhaus A Check Keypad Instruction Manual TULOX 200 Press each key in turn once Start with 1 then 2 8 9 0 The Menu and C keys are not checked Note e Each detected button is acknowledged by a high double beep e f the next key is not recognized when pressed you will hear a deeper double beep and the display will show Error en i Select menu option or Check Keypad Press keys 2 8 9 O ODO Check Keypad User Information Change U code lt 3 gt Check keypad lt 2 OK gt Check keypad il 2 OK 3 gt Check keypad 1 press Check keypad 2 press Check keypad OK The function gives you an overview of the status of each user whether they are deleted or if the code is in use Note e This function can only be carried out by the master user en User Information Enter master code D00000 depending on flash version code 3 g
15. Delay Quick Opening Code Note e User ID 99 must be active see Activate user gt page 34 e the user must be turned on see User On Off gt page 35 e first code code for starting the time delay must not user ID 99 e the code of user ID 99 must start with 99 Enter code 000090000 Example for user 01 nn Enter code of user ID 99 00000000 correct code Turn the knob after the mes sage for the correct code within 3 seconds clockwise depending on flash version STUV TULOX Code STUV TULOX Code KKKKKK Accepted Time delay value STUV TULOX Code STUV TULOX Code xx x x Accepted Steinbach amp Vollmann GmbH amp Co KG 42579 Heiligenhaus 41 Instruction Manual TULOX 200 Log Auditor Events are logged in the keypad no codes A special user called the auditor is able to view these events either on the display in abbreviated form or download them via USB port and the TULOX computer software reading detailed information is only possible on computer screens For this function there is a separate code Upon leaving the factory the lock s auditor code is configured as8 7 6 5 4 3 2 1 lf the auditor has not yet been activated factory setting the master takes over this function The following events are logged e Restart Change of batteries e Code accepted e Code denied e Code changed e New user acti
16. TULOX 200 www stuv de EN e Instruction Manual Instruction Manual TULOX 200 Using this Manual Thank you for purchasing a TULOX Safe Lock System of STUV This product was designed and manufactured in Germany It offers completely secure and easy operation of your safe unit The TULOX Instruction Manual has been specially designed to guide you step by step through the functions and operating options of this product e Please read this manual before using the product carefully to ensure safe and proper use e Please keep this manual for future reference Content Flash Version TULOX 200 Flash 1 5 General Operation Information Menu 07 Changing the Batteries 08 Operation 09 Setting Clock Opening 11 Opening by Dual Mode 12 Penalty Closing Battery Warning Tamper Evidence Notes 13 Changing the Code Master Code and User Code 14 Activate User 15 User On Off 16 Delete User 17 Check Keypad User Information 18 Setting Time Delay Values 19 Changing Time Delay Values 20 Opening when Time Delay is Active 21 Overriding Time Delay Quick Opening Code 22 Reset 23 02 Steinbach amp Vollmann GmbH amp Co KG 42579 Heiligenhaus Instruction Manual TULOX 200 Flash Version TULOX 200 Flash 7 8 General Operation Information Menu Changing the Batteries Operation Opening Opening by Dual Mode Identification Penalty Time Closing Battery Warning Tamper Evidence Notes Changing the User Code Changi
17. TUV TULOX Code STUV TULOX KkKkKKKK Denied Code STUV TULOX KkKkKKKK Accepted Code Upon leaving the factory the lock s master code is configured as 1 2 3 4 5 6 By entering the factory default master code alone the lock can not be opened After changing the master code a user must be activated see page 15 DOO OO Enter the second code DOODO Turn the knob after the mes sage for the correct code within 3 seconds clockwise Enter the code incorrect code correct code STUV TULOX Code STUV TULOX Code STUV TULOX Code KKKKKK Denied STUV TULOX KkKkKKKK Accepted Code Steinbach amp Vollmann GmbH amp Co KG 42579 Heiligenhaus Instruction Manual TULOX 200 Time Penalty due to incorrect entered Codes If an incorrect code has been entered successively four times the lock starts a blocking time of 5 minutes The blocking time starts again after two further consecutive incorrect entries 4 x incorrect code during the time penalty no e 2 further incorrect codes access to the lock j 5 min Closing Turn the knob handle counter clockwise Make sure after closing that the lock is closed properly Battery Warning First step A critical discharge battery status is shown at an early stage by a message Battery empty and signaled beeps Change the batte
18. X incorrect code STUV TULOX Code KKKKKKKK Denied correct code Turn the knob after the mes STUV TULOX f th t d Code KKKKKKKK sage or the correct co e neeepeed within 3 seconds clockwise Opening by Dual Mode Flash 7 Upon leaving the factory the lock s master code is configured as 9 8 1 2 3 4 5 6 By en tering the factory default master code alone the lock can not be opened After changing the master code a user must be activated see page 34 incorrect code STUV TULOX Check input Denied 30 Steinbach amp Vollmann GmbH amp Co KG 42579 Heiligenhaus Instruction Manual TULOX 200 STUV TULOX Check input sage for the correct code Accepted within 3 seconds clockwise correct code Turn the knob after the mes Time Penalty due to incorrect entered Codes If an incorrect code has been entered successively four times the lock starts a blocking time of 5 minutes The blocking time starts again after two further consecutive incorrect entries 4 x incorrect codes during the time penalty no 2 further incorrect codes access to the lock 5 min Time penalty Closing Turn the knob handle counter clockwise Make sure after closing that the lock is closed properly Battery Warning First step A critical discharge battery status is shown at an early stage by a message Battery em
19. a 2 OK 3 2 Enter Master code Please wait Check input 60 Load time manag OK e Load time manag OK Function was executed without problems e Error Master code Entered master code not OK 48 Steinbach amp Vollmann GmbH amp Co KG 42579 Heiligenhaus User Manual TULOX 200 PC Program Time Management Menu gt Time manag gt Enter Master Code Connect the USB cable to the PC and start the pro gram TULOX 200 Time Management There are 6 different areas Language 1 Data output Opening Times Generally Settings weekly plan is repeated weekly 2 Data is transferred into the lock Steinbach amp Vollmann GmbH amp Co KG 42579 Heiligenhaus 49 User Manual TULOX 200 3 Loading lock data Opening Times User Entry of the user specific time windows max 97 user 4 User for time configuration 5 Data is transferred into the lock 6 Loading lock data Clock 7 Readout of the date and time of TULOX 8 Setting the date and time Data 9 Loading of a preconfigured file 10 Storing the data in a file 11 Factory setting Holidays Time window for 12 special days e g holidays 12 Data is transferred into the lock 13 Loading lock data Mode 14 Disconnect User selection gt 50 Steinbach amp Vollmann GmbH amp Co KG 42579 Heiligenhaus U
20. amp Co KG 42579 Heiligenhaus User Manual TULOX 200 Ar STUV PC Program Auditor Menu gt Audit Rev gt Connect PC gt Enter Auditor Code Master code only in the case of no Au ditor code Connect the USB cable to the PC and start the program TULOX 200 Auditor CRO 9925 Language 1 Data output Event Window 2 Data output User who caused the event Date and time Event occurred Incorrect entry counter This counter is incremented for each incorrect entry of acode by one max 255 This counter can only be reset by deleting the log files Steinbach amp Vollmann GmbH amp Co KG 42579 Heiligenhaus 47 a User Manual TULOX 200 Clock 3 Displays the time of TULOX lock 4 Setting the time Logfile 5 Data output the data is displayed in the event window 6 Storing the data in a file 7 Printing of the data Tulox 8 Deletion of data 9 Disconnect Incorrect Code Counter 10 This counter is incremented for each incorrect entry of a code by 1 digit Load Time Management ne gt Select menu option or Load time management Enter master code A090000 The lock will now check your entry Lock confirms Load time management The lock will now check your entry The display will show one of the following messages Change U code lt 2 OK 35 gt Load time manag lt 1 2 OK gt gt Load time manag lt
21. cepted Time delay value Start opening window Display flashes and lock beeps in 2 sec clock Re enter valid code within the DOO OO opening window correct code Turn the knob after the mes sage for the correct code within 3 seconds clockwise STUV TULOX Code Check input Accepted Mi Steinbach amp Vollmann GmbH amp Co KG 42579 Heiligenhaus 21 a Instruction Manual TULOX 200 Opening with activated time delay Ricas oniy Start of time delay Delay time Opening window Code entry within the opening window opens the lock Overriding Time Delay Quick Opening Code Note e User ID 9 must be active see User setup e the user must be turned on see User On Off e first code code for starting the time delay must not user ID 9 e the code of user ID 9 must start with 9 ee Bu Code correct code ne STUV TULOX Accepted Enter code of user ID 9 O EDOOO ee STUV TULOX STUV TULOX correct code Turn the knob after the mes ooge krxxxxxx sage for the correct code Accepted within 3 seconds clockwise depending on flash version 22 Steinbach amp Vollmann GmbH amp Co KG 42579 Heiligenhaus Instruction Manual TULOX 200 Reset With this function the lock is reset to a predefined factory setting As a result all programmed user data will be deleted m Start men
22. cks the ID from the lock when power is applied The lock will only operate when the by the hardware submitted ID matches the stored one in the lock General Information on Operation Menu An incorrect entered number can be deleted with the C key In order to the menu options you can navigate through the menu To do so press the menu key The first menu option offered is Change U Code You can use keys 1 and 3 to move through the menu and select various menu options You may confirm your selection using the 2 key The menu is set up as follows Change U code lt 2 OR View of display Steinbach amp Vollmann GmbH amp Co KG 42579 Heiligenhaus 25 Instruction Manual TULOX 200 Change U code lt gt Change M code lt gt Activate user lt gt User on off lt gt Delete user Language User info Timeout Log Auditor Setting clock lt gt Brightness lt gt Check keypad lt gt Load time manag lt gt Auditor config Note e The menu function selected will be shown on the top line of the display for 5 seconds e f there is a black cursor flashing on the screen then the system is waiting for your entry Changing the Batteries To insert or change new batteries pull away the cover with a light Remove cover Replace cover force The cover is held in place with magnets Ensure the keys are lined up before allowing the Ins
23. ction is executed separately for each user Note e This function can only be carried out by the master user ad ey Select menu option or Delete user Enter Master code 0A000000 ie Select user number 01 97 and 99 The lock will now check your entry Lock confirms Delete user The lock will now check your entry The display will show one of the following messages e Delete user OK e Error Master code Entered master code not OK 36 Instruction Manual TULOX 200 code 3 gt Change U lt 1 2 OK Delete user lt 1 2 OK 3 gt Delete user lt 1l 2 OK 3 gt Enter Master code Enter User ID Please wait Check input 60 Delete user OK Function was executed without problems Steinbach amp Vollmann GmbH amp Co KG 42579 Heiligenhaus Instruction Manual TULOX 200 Check Keypad Press each key in turn once Start with 1 then 2 8 9 0 The Menu and C keys are not checked Note e Each detected button is acknowledged by a high double beep e f the next key is not recognized when pressed you will hear a deeper double beep and the display will show Error tart men Menu ke Sta enu y Change U code lt 1 2 OK Ir Select menu option Check keypad pci Confirm selection Check keypad 2 OK 3 gt
24. d if the code is only one digit different from existing code the code is identical to the code of a disabled user vn Select menu option or Change M Code Enter the current code 00000000 Enter the new code 0000000 Enter the new code again A0000 The lock will now check your entry Lock confirms Change M Code The lock will now check your entry The display will show one of the following messages e Change M code OK e Error New code e Error Steinbach amp Vollmann GmbH amp Co KG 42579 Heiligenhaus Change U code lt 1 3 gt Change M code l 2 OK 3 gt Change M code lt 1l 2 OK 3 gt Current code Enter New code Enter New code Enter again Please wait Check input 60 Change M code OK Function was executed without problems The first and second input of the new code are not equal Current or new code not OK note instructions above 33 A Activate User Instruction Manual TULOX 200 When supplied only the user with the master code is active Before other users can operate the lock they must be activated Note e This function can only be carried out by the master user e The code must be 8 digits long e Do not use any personal or easy to guess data for your code such as birthdays e Simple codes that are easy to gu
25. de Enter 0000000 D OOD O OOO New code Enter New code Enter again Steinbach amp Vollmann GmbH amp Co KG 42579 Heiligenhaus Instruction Manual TULOX 200 The lock will now check your entry Lock confirms Change auditor code The lock will now check your entry The display will show one of the following messages e Connect PC e Reset auditor OK e Change code OK e Error Master code e Error Current code e Error Auditor code e Error Change audit code e Error New code Entered master code not OK Entered code not OK Entered auditor code not OK Auditor not activated Auditor On via Display Start menu Menu key Select menu option or Auditor configuration Select menu option or Auditor on The lock will now check your entry Lock confirms Auditor on Steinbach amp Vollmann GmbH amp Co KG 42579 Heiligenhaus Please wait Check input 603 u WU UU L Change audit code O i Function was executed without problems Function was executed without problems Function was executed without problems Current or new code not OK note instructions above code 3 gt Change U 1 2 OK Auditor config lt 1 2 OK 3 gt Auditor config lt 1 2 OK 3 gt Auditor on lt 1 2 OK 3 gt Auditor on
26. ert the new batteries 4x 1 5V al nen magnet to pull the cover kaline AA Mignon LR6 in the key ey into position pad Make sure the right polarity is used as indicated on the casing Place the cover back on the base and snap it on with light pressure Note If the cover is not mounted the lock cannot be operated nor mally 26 Steinbach amp Vollmann GmbH amp Co KG 42579 Heiligenhaus Instruction Manual TULOX 200 After snapping the cover back on the display will show the message Cover removed for a short time This will be showed repeatedly until Cover removed a valid code has been entered If you see this message without having removed the cover then check the keypad for potential tampering For another 3 sec after this entry the display will show the message STUY TULOX Power supply was interrupted This will also be shown repeatedly Power supply until a valid code has been entered was inte fr pt ed Installation of Batteries and first use Remove the cover with a slight force Insert the batteries and replace Example the cover Enter code 0A000000 FLASH VERSION 8 Enter Master code Il Please wait Check input 60 LI Setting clock 31 01 15 14 19 01 01 14 00 00 The lock will now check your entry Steinbach amp Vollmann GmbH amp Co
27. ess may not be used Avoid to record the selected code or save to disk Should that for various reasons can not be avoid so the recorded code is to be kept safe and to be protected against unauthorized access by third parties e New codes are rejected if the code is only one digit different from existing code the code is identical to the code of a disabled user e f the new code is rejected the function is exited immediately e For security reasons you should change the code only when the safe is open Before closing the door check the correct functioning of the new codes e User number 99 for bypassing time delay Quick Opening Code gt see page 38 can be created only if Time delay is set off Time delay is set on delay time has passed and the lock status is within the opening window Operation with Time Delay gt see page 38 ne i Select menu option or Activate user Enter master code 00000000 Select user number Example 01 97 and 99 Enter new code again DOOO OOO The lock will now check your entry Lock confirms Activate user 34 code 3 gt Change U Sad 2 OK Activate user lt 1 2 OK 3 gt Activate user lt 2 OK 3 gt Enter Master code Enter User ID New code Enter New code Enter again Please wait Check input 60 Activate user
28. f the following messages e Time delay Deleted e Error Master code e Error Function was executed without problems Entered master code not OK Turning off the function can only be performed within the opening window Opening when Time Delay is Active Note e Entering an invalid code in the menu within the opening delay time will cancel the entire procedure e Only with Flash 7 two codes can be entered in the opening window see opening according to the dual mode identification Ks HE Start opening window Display flashes and lock beeps in 2 sec clock Re enter valid code within the opening window 00000000 Turn the knob after the mes sage for the correct code within 3 seconds clockwise correct code 40 STUV TULOX Code STUV TULOX KKKKKKKK Accepted Code Time delay value STUV TULOX Code i STUV TULOX KKKKKKKK Accepted Code Steinbach amp Vollmann GmbH amp Co KG 42579 Heiligenhaus Instruction Manual TULOX 200 First code entry Start of time delay Delay time Opening window Code entry within note code of user ID 99 First code entry l Start of time delay Delay time Code entry of user ID 99 within the delay the opening window time opens the lock opens the lock immediately Opening with activated time delay Opening with overriding time delay Overriding Time
29. g Auditor lt 1 2 OK 32 gt Log Auditor lt 1 2 OK 3 gt Event memory a 1 2 OK a gt Event memory a 2 OK 3 gt Enter Code KKKKKKKK Please wait Check input 60 S15 01 15 14 19 00 Protocol 21 lt 2 OR 3 2 43 Steinbach amp Vollmann GmbH amp Co KG 42579 Heiligenhaus A Instruction Manual TULOX 200 Reset Auditor via Display Start menu Select menu option Log Auditor Confirm selection Select menu option Reset auditor Confirm selection Enter auditor code The lock will now check your entry Lock confirms Reset auditor Select menu option Log Auditor Confirm selection Select menu option Change auditor code Confirm selection Enter auditor code Enter new auditor code Enter new auditor code again DOO OO 44 11 Menu key Change U code lt 1 2 OK 3 gt or Log Auditor lt 1 2 OK 3 gt Log Auditor lt 1 2 OK 3 gt Reset auditor lt 1 2 OK 3 gt Reset auditor lt 1 2 OK gt Enter Auditor code Code KKKKKKKK Please wait Check input 60 Reset auditor OK Change U code lt 1 2 OK 3 gt Log Auditor lt 1 2 OK 3 gt Log Auditor x 2 OK 2 gt lt 1 Change audit code 2 OK 3 gt lt 1 Change audit code 2 OK 3 gt Current co
30. lect menu option Timeout Lock confirms Timeout The lock will now check your entry The display will show one of the following messages e Timeout OK e Error Incorrect time entered Setting clock Select menu option or setting clock Enter Code 0A090000 The lock will now check your entry Lock confirms Setting clock The lock will now check your entry The display will show one of the following messages Steinbach amp Vollmann GmbH amp Co KG 42579 Heiligenhaus Change U code lt 2 OK 3 gt Timeout lt 1l 2 OK 3 gt Timeout lt l 2 OK 3 gt Timeout 04 10 sec Timeout OK Function was executed without problems Change U code lt 1 2 OK 3 2 Setting clock lt 1 2 DR 3 gt Setting clock lt 1 2 OK 3 gt Enter Master code Please wait Check input 60 Setting the clock 31 01 125 14 19 01 01 14 00 00 59 PN Instruction Manual TULOX 200 e Setting clock Function was executed without problems e Error Master code Entered master code not OK Error Incorrect time entered Opening Upon leaving the factory the lock s master code is configured as9 8 1 2 3 4 5 6 For security reasons change the factory configured master code immediately Enter the code DOODOO OOO EN STUV TULO
31. lowing messages 10 Steinbach amp Vollmann GmbH amp Co KG 42579 Heiligenhaus Instruction Manual TULOX 200 e Timeout OK Function was executed without problems e Error Incorrect time entered Setting Clock tart men Menu ke Sta Sny y Change U code lt 1 2 OR a gt Select menu option P on Setting clock Setting clock 1 2 OK 3 gt Confirm selection Setting clock lt l 2 OK 3 gt Enter Master code Enter Code D09000 The lock will now check your entry Please wait Check input 60 Setting clock Lock confirms i 31 01 15 14 19 Setting clock 01 01 14 00 00 The lock will now check your entry The display will show one of the following messages e Setting clock OK Function was executed without problems e Error Master code Incorrect entered master code e Error Incorrect time entered Steinbach amp Vollmann GmbH amp Co KG 42579 Heiligenhaus _ _ I A Opening Instruction Manual TULOX 200 Upon leaving the factory the lock s master code is configured as 1 2 3 4 5 6 For security reasons change the factory configured master code immediately Enter the code OD OOOOO O Turn the knob after the mes sage for the correct code within 3 seconds clockwise incorrect code correct code Opening by Dual Mode Flash 4 S
32. ng the Master Code Activate User User On Off Delete User Check Keypad User Information Setting Time Delay Values Changing Time Delay Values Opening when Time Delay is Active Overriding Time Delay Quick Opening Code Log Auditor Auditor Configuration PC Program Auditor Loading Time Control PC Program Time Control Setting Clock Reset Silent Alarm Duress Opening the Lock with Mechanical Key optional Disassembling Keyboard Opening Closing with Key Troubleshooting Guide Steinbach amp Vollmann GmbH amp Co KG 42579 Heiligenhaus 25 26 27 30 31 32 33 34 35 36 37 38 39 40 41 42 43 47 49 51 52 53 54 55 03 Instruction Manual TULOX 200 Flash1 1 User e Changing User Code e Check Keypad e Reset u Flash2 1 Master 1 User Time Delay e Changing Code Master and User Code e Activate User e Delete User e Check Keypad e Reset e Time Delay u Flash3 1 Master up to 4 User Time Delay e Changing Code Master and User Code e Activate User e User On Off e Delete User e Check Keypad e User Information e Reset e Time Delay Flash 4 Dual Mode 1 Master up to 9 User Time Delay e Changing Code Master and User Code e Activate User e Delete User e Check Keypad e User Information e Reset e Time Delay 04 Steinbach amp Vollmann GmbH amp Co KG 42579 Heiligenhaus L L L Flash 5 Flash 7 Flash 8 Instruction Manual TULOX
33. or opening is possible e Only with Flash 4 two codes can be entered in the opening window See opening according to the dual mode identification depending on flash version Steinbach amp Vollmann GmbH amp Co KG 42579 Heiligenhaus 19 Select menu option Time delay Confirm selection Enter Master code Opening time delay e 20 minutes Example pee window 6 minutes Example The lock will now check your entry Lock confirms Time delay The lock will now check your entry Menu key 000000 The display will show one of the following messages e Time delay OK e Error Master code e Error Time delay Instruction Manual TULOX 200 code 3 gt Change U lt 1 OK Time delay lt 1 2 OK 3 gt Time delay 1 2 OK 3 gt Enter Master code Enter Time delay value 00 99 min Enter Opening window 81 19 min Please wait Check input 60 Time delay OK Function was executed without problems Entered master code not OK Entered time not OK Changing the Time Delay Values possible during the opening window only Note e Switching off the function can only be performed during the opening window after elapse of delay time e After switching off the function code entry is possible to open the lock e When new times are set during
34. pty and signaled beeps Change the batte ries then 4 pieces 1 5V Alkaline AA Mignon LR6 Battery empty Second step At this stage the supply voltage has reached a critical value therefore an opening can not be exe cuted After entering the code Battery empty is displayed and the lock will not open Tamper Evidence After snapping the cover back on the display will show the mes sage Cover removed for a short time This will be showed re Cover removed peatedly until a valid code has been entered If you see this message without having removed the cover then check the keypad for potential tampering Steinbach amp Vollmann GmbH amp Co KG 42579 Heiligenhaus 31 ay Instruction Manual TULOX 200 Change User Code Note e The code must be 8 digits long e Do not use any personal or easy to guess data for your code such as birthdays e Simple codes that are easy to guess may not be used Avoid to record the selected code or save to disk Should that for various reasons can not be avoid so the recorded code is to be kept safe and to be protected against unauthorized access by third parties e For security reasons you should change the code only when the safe is open Before closing the door check the correct functioning of the new codes e New codes are rejected if the code is only one digit different from existing code the code is identical to the code of a disabled user
35. r vn a Enter the current code 000000 Enter the new code 000000 Enter the new code again 00000 The lock will now check your entry Lock confirms Change U code The lock will now check your entry The display will show one of the following messages Change U code Sl 2 OK 3 2 Change U code lt 1 2 OK 35 gt Current code Enter New code Enter New code Enter again Please wait Check input 60 Change U code OK e Change U code OK Function was executed without problems e Error New code The first and second input of the new code are not equal e Error Current or new code not OK note instructions above 14 Steinbach amp Vollmann GmbH amp Co KG 42579 Heiligenhaus Instruction Manual TULOX 200 Activate User When supplied only the user with the master code is active Before other users can operate the lock they must be activated Note e This function can only be carried out by the master user e The code must be 6 digits long e Do not use any personal or easy to guess data for your code such as birthdays e Simple codes that are easy to guess may not be used Avoid to record the selected code or save to disk Should that for various reasons can not be avoid so the recorded code is to be kept safe and to be protected against unauthorized access by third parties e Ne
36. ser Manual TULOX 200 E a a EEE amn 0000 EARRA Bae ee Seeeeeeeenn Setting Time Open Time Open Time User Holidays Appears when changing the times mouse click in the editor window Time can be set here Reset With this function the lock is reset to a predefined initial state As a result all programmed user data will be deleted 73 Start menu Menu key en Bo 1 2 OK 3 gt Select menu option or 7 Reset Reset lt 1 2 OK 3 gt Confirm selection Reset lt 1 2 OK 3 gt Enter master code 0000000 Enter Master code Steinbach amp Vollmann GmbH amp Co KG 42579 Heiligenhaus 51 The lock will now check your entry Lock confirms Reset The lock will now check your entry The display will show one of the following messages e Reset OK e Error Master code Entered master code not OK Silent Alarm with external Hardware only Instruction Manual TULOX 200 Please wait Check input 60 Reset OK Function was executed without problems The lock system can send a silent signal to an alarm system if the user is being coerced into ope ning the lock with the entry of a special code which also opens the lock The last digit of the user or master s code should be increased or decreased by 1 to activate the silent alarm signal Upon delivery the master code is fac
37. t Change U ail 2 OK User info lt 1l 2 OK 3 gt User info lt 1l 2 OK 3 gt Enter Master code Steinbach amp Vollmann GmbH amp Co KG 42579 Heiligenhaus Instruction Manual TULOX 200 ie Br 60 Already in use Deleted The information in the display have the following meanings e Already in use A code has already been enabled for the user number and is used e Deleted The user number is still free and another code may be activated e Not available The use of the user ID is not possible with this lock Setting the Time Delay Values Setting the delay Delay Code entry Start of time delay 01 to 99 minutes 2 digits Sets the function This time has to elapse before the lock can be opened Time delay Opening window Code entry within the opening window Opening window a g opens the lock 01 to 19 minutes 2 digits Within this period the code must be entered again to open the lock Note e This function can only be carried out by the master user e A shorter opening delay time must be entered within the opening window after the opening time delay e f the function is selected before or during the opening delay time the opening delay time can only be extended Shorter times are not accepted e After changing the times the opening window will continue Code entry f
38. teries 4x 1 5V al kaline AA Mignon LR6 in the key pad Make sure the right polarity is used as indicated on the casing Place the cover back on the base and snap it on with light pressure Note If the cover is not mounted the lock cannot be operated nor mally After snapping the cover back on the display will show the message Cover removed for a short time This will be showed repeatedly until Cover removed a valid code has been entered If you see this message without having removed the cover then check the keypad for potential tampering For another 3 sec after this entry the display will show the message STUV TULOX Power supply was interrupted This will also be shown repeatedly Power supply until a valid code has been entered was interrupted 08 Steinbach amp Vollmann GmbH amp Co KG 42579 Heiligenhaus Instruction Manual TULOX 200 Installation of Batteries and first use Example D90000 Remove the cover with a slight force Insert the batteries and replace the cover Enter Code The lock will now check your entry Set the date and time Configuring the Language You can select various languages Note FLASH VERSION 5 Enter Master code Il Please wait Check input soso Oba oa Setting clock 31 01 15 14 19 01 01 14 00 00 e After interrupting the power supply for
39. tory set to9 8 1 2 3 4 5 6 Enter the first 7 digits of the 0000000 code Enter the 8 digit of the code Turn the knob after the mes sage for the correct code within 3 seconds clockwise The lock will now check your entry The lock was opened and simul taneously triggered alarm 52 STUV TULOX Code STUV TULOX KKK KKK KK Code Please wait Check input 60 LI I STUV TULOX Check input Accepted Steinbach amp Vollmann GmbH amp Co KG 42579 Heiligenhaus Instruction Manual TULOX 200 Ar STUV EMERGENCY FUNCTION Open the Lock with Mechanical Key optional Depending on the version the TULOX electronic safe lock system is shipped with a mechanical key With this key the lock can be opened in case a valid user and code are unavailable or in the event that the keypad has been tampered with Note e The key must always be taken out after locking so that it is inaccessible to unauthorized parties e The key must always be kept in a safe place e Do not leave the key in your safe e When a key is lost replace the lock immediately Disassembling your Keyboard The keyhole of the lock lies behind the keyboard Pull away the cover with alight force The cover is held in place with magnets Remove the two screws and slide the keyboard off the safe door The axis and the cables are visible Mounting screws Key Ke
40. u Menu key Change U code lt 1 2 OK 3 gt Select menu option or Mi Reset Reset lt 1 2 OK 3 gt Confirm selection Reset lt 1 2 OK 3 gt Enter Master code Enter Master code DOO O O The lock will now check your entry Please wait Check input 603 VD OOUUO Lock confirms Reset Reset OK The lock will now check your entry The display will show one of the following messages e Reset OK Function was executed without problems e Error Master code Entered master code not OK Steinbach amp Vollmann GmbH amp Co KG 42579 Heiligenhaus 23 ENGLISH D4 Steinbach amp Vollmann GmbH amp Co KG 42579 Heiligenhaus Instruction Manual TULOX 200 Ar STUV Instruction Manual TULOX 200 Flash 7 to 8 For information about the installation of the lock please refer to the separate installation manual The TULOX electronic safe lock system is equipped with advanced power management features After a few seconds without operation the system turns off the display and starts the power saving mode Pressing any key will wake the system The display will show the following screen SIUV TULOX View of display General Information Encrypting In the Flash versions 7 8 the keypad entry unit and lock are paired together with a matching ID Both in the fitting and in the lock a unique ID is stored The fitting che
41. vated e User On Off e User deactivated e User information e Time delay e Log Auditor e Event log e Reset auditor e Auditor code changed e Auditor On e Auditor Off e Loading time management e Setting clock e Reset e Time penalty e Silent alarm e Cover removed 42 Steinbach amp Vollmann GmbH amp Co KG e 42579 Heiligenhaus Instruction Manual TULOX 200 Please perform the following steps with the lock to read the information on a computer Read Event Memory Detail on PC Menu key Select menu option or Log Auditor Connect PC en en Enter code 0A000000 MOO OOO auditor master Change U code lt 2 OK 3 gt Log A Auditor lt 1 OK 3 gt Log Auditor lt l 2 OK 3 gt Connect PC lt 1l 2 OK 3 gt Connect PC lt 2 OK 3 gt Enter Code KKKKKKKK The lock will now check your entry Please wait Check input 60 Lock confirms Connect PC Connect PC OK Read Event Memory Short form on display Menu key Select menu option or Log Auditor Event memory venues a 00000000 OOO OOO auditor Enter code master The lock will now check your 2 Change U code lt 1 2 OK gt Lo
42. w codes are rejected if the code is only one digit different from existing code the code is identical to the code of a disabled user e f the new code is rejected the setup is exited immediately e For security reasons you should change the code only when the safe is open Before closing the door check the correct functioning of the new codes u Select menu option or Activate User Enter Master code D00000 The lock will now check your entry Lock confirms Activate User The lock will now check your entry The display will show one of the following messages depending on flash version code 3 gt Change U lt l 2 OK Activate user lt 1l 2 OK 3 gt Activate user lt 1l 2 OK 3 gt Enter Master code Enter User ID New code Enter New code Enter again Please wait Check input 60 LI I Activate user OK maximum number of users depending on flash version with Flash 2 selection of user number is not possible Steinbach amp Vollmann GmbH amp Co KG 42579 Heiligenhaus A e Activate user OK e Error Master code e Error Already in use e Error Entered master code not OK User On Off Instruction Manual TULOX 200 Function was executed without problems A code is already enabled for the user ID The user number is not possible
43. with this lock All normal users are switched ON or OFF If the user codes are switched OFF the lock can be opened with the Master code only Note e This function can only be carried out by the master user k User On Off Enter Master code Da000OO The lock will now check your entry Lock confirms User On Off The lock will now check your entry The display will show one of the following messages e User On Off OK e Error Master code Entered master code not OK depending on flash version code 3 gt Change U lt 1 2 OK User on off lt 1l 2 OK 3 gt User on off lt 1l 2OK 3 gt Enter Master code Please wait Check input 6003 OUUU User on off OK Function was executed without problems Steinbach amp Vollmann GmbH amp Co KG 42579 Heiligenhaus Instruction Manual TULOX 200 Delete User This function is executed separately for each user Note e This function can only be carried out by the master user _ a Delete User Enter Master code Select user number 1 9 DOO O O The lock will now check your entry Lock confirms Delete User The lock will now check your entry The display will show one of the following messages e Delete user OK e Error Master code Entered master code not OK depending on flash version Change U code lt
44. yhole Steinbach amp Vollmann GmbH amp Co KG 42579 Heiligenhaus 53 Instruction Manual TULOX 200 Depending on mounting the cable has been run through the axis into the safe see image page 51 or through a seperate drilling hole If the cable is run through the axis you have to unplug the cable with a short pull from the lock Only now you can put the keyboard with the cable to the side Remove the axis from the keyhole Now the keyhole is accessible and you can open the lock with the key Before the lock can be opened again by entering a code the cable must be replaced and properly installed For this purpose order a service technician If the cable is run through a separate hole you only have to pull the axis out of the keyhole Now the keyhole is accessible and you can open the lock with the key Before the lock can be opened again by entering a code the axis and the keyboard must be installed properly Opening with Key Insert the key fully into the lock Turning the key 170 clockwise opens the lock The key is used to operate the lock When the key is used as a handle for opening the door we point out that only limited amount of force can be transferred from the key In case of overload damage to lock and key may occur Closing with Key Locking is done in the opposite way of the opening 54 Steinbach amp Vollmann GmbH amp Co KG e 42579 Heiligenhaus Instruction Manual TULOX 200 Troubleshooting Guide
Download Pdf Manuals