Home
Aroma-Nebuliser User Manual
Contents
1. OF THE INNER STEM ONLY USE ESSENTIAL OILS AND NOT WATER OR OTHER PRODUCTS see below this step by step for full details 4 Place the glass stopper into the top of the chamber ensuring all protective wrapping has been removed 5 With dry hands plug the power supply into the unit and a standard electrical outlet 6 Turn the silver dial on the ceramic base to the right to turn on the unit The LED light should come on and the unit should gently vibrate when the Nebuliser is turned on Note turning the dial to the right increases the intensity of the diffusion For best results and to ensure a long life for your lonic Nebuliser we do not recommend using any any viscous essential oils as they will clog up the inner mechanics of your diffuser over time We also do not recommend that you add any essential oil dilutions massage oils or carrier oils in this product Examples of viscous essential oils include Benzoin Jasmine Absolute Myrrh Patchouli Sandalwood and Vetiver CLEANING INSTRUCTIONS Clean unit thoroughly 1 2 times a week or when a new oil is used When cleaning the machine please follow these steps 1 Ensure the unit is properly switched off before removing the glass chamber from the ceramic base 2 Remove the glass stopper and pour out any remaining oil 3 Place a capful 3 5ml of isopropyl alcohol IPA or rubbing alcohol into the chamber and gently swirl it around for 2 3 minutes before emptying USE CAUTION WHE
2. electrical outlet on and the light is Check that the main outlet is working properly not working Check that the fuse has not gone in the power supply plug The light is on To be working the unit should be vibrating gently for two minutes with one however the unit minute break does appear to Check that it has not already been on for two hours if this is the case be vibrating or simply turn the unit off and back on again this should reset the timer dispersing mist Check that there is adequate oil in the glass chamber If this does not work try thoroughly cleaning the glass chamber to remove any built up residue that could be blocking the unit SEE CLEANING INSTRUCTIONS Check that the chamber is properly installed and that the stopper is in place Restart the unit There is less Check that there is adequate oil in the glass chamber dispersal than usual If this does not work try thoroughly cleaning the glass chamber to remove when the unit is any built up residue that could be blocking the unit SEE CLEANING INSTRUCTIONS Check that the chamber is properly installed and that the stopper is in place Restart the unit powered on We will be happy to assist you with any further issues or questions you may have Please feel free to contact us using any of the options below Full details of how each of our essential oils and blends can benefit you are available on our website www absolute aromas com ABSOLUTE ar
3. Aroma Nebul CONTENTS Glass Stopper 1 Glass Chamber 2 Ceramic Base Unit 3 Power Supply OTHER ELEMENTS Internal Stem attached 4 On Off Switch and Intensity Dial 5 This Professional Cold Air Aromatherapy Nebuliser changes the essential oil from liquid to an extremely fine mist without destroying any chemical constituents and is a very effective way of diffusing essential oils for around the home or office SAFETY OPERATION DIGITAL CONTROL USER FRIENDLY FEATURES SUGGESTION The Nebuliser creates a fine mist of your essential oils without the use of any flame or heat source The diffuser will function on a 2 minutes on and 1 minute off basis for two hours allowing the oil to last longer Energy efficient Digitally programmed to stop automatically when minimum oil level is reached To save energy the power automatically turns off after 2 hours The diffusion intensity level can be adjusted to reflect your personal needs This product is also easy to clean Up to 5 different colours of LED light can be used as a night light Try adding 4 drops of lavender oil 2 drops of peppermint oil and 4 drops of rosemary oil to create a fresh positive and clear aroma OPERATING INSTRUCTIONS 1 Install the glass chamber onto the ceramic base 2 Remove the glass stopper from the chamber 3 Place between 10 and 20 drops of undiluted essential oil into the chamber DO NOT FILL PAST 2 3
4. N USING IPA AS THIS IS A FLAMMABLE IRRITANT SEE THE LABEL ON THE BOTTLE FOR FULL CAUTIONS DO NOT USE A CLEANING AGENT 4 Allow all of the remaining alcohol to evaporate before reinstalling the chamber Alternatively gently soak the glass chamber in warm soapy water for approximately ten minutes and rinse DO NOT EMERSE THE CERAMIC BASE OR POWER SUPPLY IN WATER SAFETY INSTRUCTIONS 1 Please follow the instructions to operate the unit 2 Use only the power supply provided to operate the unit 3 Do not fill above 2 3 of the inner stem inside the chamber 4 Do not place water thick oils or products other than pure undiluted essential oils into the chamber Keep the unit on a flat and secure surface at all times Do not operate the unit with wet hands 7 Ifa problem arises shut off and unplug the unit from the power Do not attempt to open the unit repairs should only be carried out by a qualified service centre 8 Do not immerse the ceramic base or power supply in water and ensure glass chamber is properly dry after cleaning before reinstalling into the base 9 The unit will automatically stop working when the oil level reaches its minimum level or when it has been on for two hours 10 For indoor use only 11 Keep away from young children and pets au TROUBLESHOOTING SOLVING PROBLEMS PROBLEM SOLUTION The unit does not Check that the power supply is securely plugged into both the unit and appear to be turning
5. omas LAVENDER High Altitude lavandula angustifolia ABSOLUTE aromas b LAVENDER y High Altitude ende angustifolui 10ml 1 3fl oz Absolute Aromas Ltd Tel 44 0 1420 540400 www absolute aromas com facebook Y O Tube sales absolute aromas com facebook OJ Youll