Home
User manual
Contents
1. warnings when the temperature falls IF only the Power LED is flashing once per minute then the temperature in the room is 18 C or above Other temperatures below this will result in one of the following indications e Warning The Warning LED will flash Yellow once every 5 seconds when the temperature is 12 C or above and less than 18 C There is a potential risk of ill health e Danger The Alarm LED will flash Red once every 5 seconds and the alarm will sound briefly every 2 minutes when the temperature is 7 C or above and less than 12 C The temperature in the room is far too low This temperature range 10 can lead to hypothermia There is a high risk of ill health Critical The Alarm LED will flash Red every second and the alarm will repeatedly sound for 30 seconds followed by a break of 30 seconds when the temperature is below 7 C The temperature in the room is dangerously cold Should any of these indications occur you should take steps to increase the temperature or if this is not possible try to make yourself warmer When the alarm indicates Danger or Critical temperature ranges it is possible to temporarily silence the alarm for 30 minutes This will allow for any measures you have taken fo increase the temperature in the room to take effect If the temperature continues to fall significantly the alarm will exit silence mode NORMAL 18 C and above WARNING DANGER CRITICAL
2. 6 C and below TESTING YOUR ALARM Test the sounder power pack and circuitry by pressing and releasing the Test Silence button to confirm that the detector is operating properly The sounder should sound as soon as the button is pressed and the Alarm LED will illuminate red indicating that the sounder is working and the power pack is providing power fo the unit This test for the sounder battery and circuitry should be performed on a weekly basis ERROR LOW POWER PACK WARNING The alarm regularly carries out a series of checks on it s circuitry and power pack If the alarm detects an error or if the power pack level is low the alarm will emit a single chirp once every minute and all three LEDs will flash together once every minute If the unit is still within warranty contact the FireAngel helpdesk on 0800 141 2561 If the product is out of warranty replace immediately with a comparable product CAUTION Your FireAngel Cold Alarm is a sealed electrical device and no attempt should be made to open the case Attempting to open the case will invalidate your warranty WARNING DO NOT ATTEMPT TO OPEN DO NOT BURN TECHNICAL INFORMATION Model CDA 9X Power Pack Life Estimated 10 years Life of product Operating Temperature Range 10 C 14 F to 40 C 104 F Operating Humidity Range 30 90 RH relative humidity Weight inc batteries 60 grams 2 10z Dimensions W
3. in stock This warranty applies to the original retail purchaser from the date of original retail purchase and is not transferable Proof of purchase is required 20 Warranty disclaimers This warranty does not cover damage resulting from accident misuse disassembly abuse or lack of reasonable care of the product or applications not in accordance with the user manual It does not cover events and conditions outside of Sprue Safety Products Ltd s control such as Acts of God fire severe weather etc It does not apply to retail stores service centres or any distributors or agents Sprue Satety Products Ltd will not recognise any changes fo this warranty by third parties Sprue Safety Products Ltd shall not be liable for any incidental 2 or consequential damages caused by the breach of any expressed or implied warranty Except to the extent prohibited by applicable law any implied warranty of merchantability or fitness for a particular purpose is limited in duration to 1 one year This warranty does not affect your statutory rights Sprue Safety Products ltd shall not be liable for any loss of use damage cost or expense relating to this product or for any indirect or consequential loss damages or costs incurred by you or any other user of this product 22 RETURNS We recommend that you contact the FireAngel Technical Support Line in the first instance on 0800 141 2561 text phone users dial 18001 08
4. 00 141 2561 or callers from EIRE dial 1 800 523171 as we may be able to remedy the problem quickly over the phone this is to prevent unnecessary returns that take a longer time to process Alternatively e mail technicalsupport fireangel co uk If there is a fault that we are unable to resolve then our technical support team member will provide you with a returns authority number so that your 23 product can be returned for testing To return your FireAngel CDA 9X under warranty send it suitably packed and switched off with postage prepaid a note indicating the returns authority number and describing the reason for return with proof of purchase to Sprue Safety Products Ltd Vanguard Centre Sir William Lyons Road Coventry CV4 7EZ UK 24 DISPOSAL Waste electrical products should not be disposed of with regular household waste Please recycle where facilities exist Check with your local authority retailer or the FireAngel Technical Support Line see page 23 for contact details for recycling disposal advice as regional variations apply You can also return your cold alarm to us for disposal For return address see the section on Returns Please include a note contirming the product is being returned for disposal 25 NOTES NOTES
5. 93mm x H 65mm x D 28mm FURTHER INFORMATION The FireAngel Cold Alarm is designed to offer an early warning of unhealthy low indoor temperatures It will not prevent ill health due to low indoor temperatures It will however alert you to low indoor temperatures in order that you can take steps to improve your environment Neither the manufacturer nor the supplier nor other retailers can be held responsible for ill health or death from cold related illnesses WARRANTY Sprue Safety Products Ltd warrants to the original purchaser that its enclosed CDA 9X Cold Alarm be free from defects in materials and workmanship under normal residential use and service for a period of 1 one year from the date of purchase Provided it is returned with postage prepaid and proof of purchase Sprue Safety Products Ltd hereby warrants that during the 1 one year period commencing from the date of purchase Sprue Satety Products Ltd at its discretion agrees to replace the unit free of charge The warranty on any replacement FireAngel CDA 9X Cold Alarm will last for the remainder of the period of the original warranty in respect of the detector originally purchased that is from the date of original purchase and not from the date of receipt of the replacement product Sprue Satety Products Ltd reserves the right to offer an alternative product similar to that being replaced if the original model is no longer available or
6. CDA 9X User Manual F refingel COLD ALARM Raising the alarm when the temperature drops GNO4A69 R2 Technical Support Line 0800 141 2561 Email info fireangel co uk Web www fireangel co uk Sprue Safety Products Ltd Vanguard Centre Sir William Lyons Road Coventry CV4 ZEZ UK CONTENTS INTRODUCTION 4 INSTALLATION 7 PRODUCT ACTIVATION 8 UNDERSTANDING YOUR 9 COLD ALARM TESTING YOUR ALARM 13 ERROR LOW POWER PACK 15 WARNING TECHNICAL INFORMATION 17 FURTHER INFORMATION 18 WARRANTY 19 RETURNS 23 DISPOSAL 25 Note This User Manual is also available in large text and other formats Please call 0800 141 2561 for further information 3 INTRODUCTION Congratulations You ve made a wise investment in an innovative product and your personal safety The CDA 9X Cold alarm is one of a new generation of domestic life safety products from FireAngel Limited which combines the latest technology and innovative design to provide an aesthetically pleasing and effective contribution to your home safety The FireAngel range of products is constantly being improved and expanded Please visit www fireangel co uk to find out about the latest additions to our product range 4 During an average winter more than 25 000 people die as a result of cold weather in the UK and Ireland Extremely cold weather can cause mild hypothermia which increases the risks of some illnesses
7. including heart attacks strokes and respiratory disease and the likelihood of falls Cold weather and poorly heated homes constitute a severe risk to health particularly the elderly the infirm and the very young This FireAngel Cold Alarm will warn you when the temperature of the room in which the alarm is installed is falling to a dangerously low level The alarm should provoke you to concentrate heating in a single room to move to a warmer area or fo seek outside help before hypothermia or worse occurs INSTALLATION The cold alarm can be wall mounted using the screw and screw anchor provided or it can be free standing on a hard flat surface We recommend it is installed in an area where you spend most time Keep the alarm away from drafts direct sunshine and direct heat sources The alarm is portable PRODUCT ACTIVATION Your cold alarm is powered by a sealed power pack which will provide power for the lifetime of the product which is estimated at 10 years To activate the alarm simply switch the alarm on by sliding the switch on the side of the alarm to the ON position When the alarm is switched on all 3 LEDs will flash briefly and the alarm will chiro once UNDERSTANDING YOUR COLD ALARM The Power LED will flash green once per minute to indicate that the alarm is switched on Power NER Y Alarm Your cold alarm is designed to give a series of visual and audible
Download Pdf Manuals
Related Search
Related Contents
Canon C70 All in One Printer User Manual "取扱説明書" マシューズ SCP-620CMFクリーナー Samsung SL-C2620DW Lietotāja rokasgrāmata Design House 539221 Instructions / Assembly Viking VGIC486-4Q* User's Manual 取扱説明書(PDF:2030KB) Copyright © All rights reserved.