Home

MULTI XS 3600 - Active Robots, Ltd.

image

Contents

1. the positive pole of the battery and the black wire to the negative pole Begin Charging 1 Set the correct voltage for the battery by pushing the Mode Selector Button until the light for the correct voltage is lit see Bat tery Types and Settings 2 When you are sure the battery leads are correctly placed connect the power cord to the power outlet to begin charging If the battery leads are wrongly connected the pole changing switch will ensure the battery and charger are not damaged The fault indica tor will light In which case start from the beginning again 3 The charging lamp will now indicate charging or the mainte nance lamp il will indicate that the battery is fully charged If the voltage drops the charger sends a pulse to the battery The length of the pulse depends on how much the voltage has dropped The charger can be connected for months 4 lf nothing happens If the voltage indicator is lit but no other lamp is lit there could be a bad connection to the battery or chassis or the battery could be faulty Check the wall power outlet If you experience problems start with the sensitive connection between the battery clamps and the charger 5 Charging can be stopped at any time by disconnecting the supply cord or by setting the charger on Standby Always remove the power cord from the power outlet before disconnecting the battery leads from a battery in a vehicle When you stop charging a battery in a vehic
2. 1 Ah month A normal figure for other charger is 1 Ah day which could ruin your battery Quality of the current and voltage is very important A linear charger produces a current with a high ripple High current ripple heats up the battery and makes the positive electrode age prema turely High voltage ripple could harm other equipment connected to the battery Multi XS 3600 produces a high quality current with very low ripple There is no need to disconnect the battery from the vehicle LIMITED WARRANTY CTEK SWEDEN AB Rostugnsv 3 SE 776 70 VIKMANSHYTTAN SWEDEN issues this limited warranty to the original purchaser of this product This limited warranty is not transferable CTEK SWEDEN AB guarantees this unit for two years from the date of purchase against defect workmanship or material It is the obliga tion of the purchaser to forward the unit together with proof of pur chase to the manufacturer or its representative with transportation cost prepaid This warranty is void if the unit is abused handled carelessly or repaired by anyone other than CTEK SWEDEN AB or its authorized representative CTEK SWEDEN AB makes no warranty other than this limited warranty and expressly excludes any implied warranty including any warranty for consequential damages This is the only expressed limited warranty and CTEK SWEDEN AB neither assumes nor authorizes anyone to assume or make any other obligation towards the product other than this limite
3. Switch Mode BATTERY CHARGER For lead acid batteries 1 2 120Ah MULTI XS 3600 User s Manual and a guide to professional battery charging For Starter Deep Cycle batteries cCTEK INTRODUCTION The MULTI XS 3600 is a switch mode charger with pulse mainte nance and is one of a series of professional chargers from CTEK SWEDEN AB It represents state of the art technology within battery charging A MULTI XS 3600 will prolong the service life of your battery Please read this manual carefully and follow the instructions CHARGING Charging batteries in a vehicle 1 The power cord should be removed from the power outlet before connecting or disconnecting the battery leads 2 Identify which of the poles is the earth connected to the chas sis The earth is normally connected to the negative terminal 3 Charging of negative earthed battery Connect the red wire to the positive pole of the battery and the black wire to the vehicle chassis Make sure the black wire is not connected close to a fuel hose or the battery 4 Charging of positive earthed battery Connect the black wire to the negative pole of the battery and the red wire to the vehicle chassis Make sure the red wire is not connected close to a fuel hose or the battery Charging of a battery not connected to a vehicle 1 The power cord should be removed from the power outlet before connecting or disconnecting the battery leads 2 Connect the red wire to
4. batteries Mode 14 4V 3 6A Normal setting for wet batteries MF and for most GEL batteries teries in minus degrees Mode 14 7V 3 6A This setting is recommended for many AGM batteries such as Optima Maxxima and ok Odysseys This mode is also useful for charging bat CHARGING CYCLE MULTI XS 3600 operates in a three step fully automatic cycle IUoUp It begins charging with an almost constant current 0 8 Aor 3 6 A until maximum voltage 14 4 V or 14 7 V is reached The charger changes mode at this point It locks the voltage at maximum level and allows the current to drop The MULTI XS 3600 switches automatically to pulse maintenance charging when the current drops to 0 4 A The charging cycle restarts if the battery voltage drops to 12 8 V die amp or 12 9 V gt Voltage Current Voltage Current Time Bulk Charging where 80 of the energy is returned The charger delivers an almost constant current until the battery voltage reaches maximum level Absorption Charging up to almost 100 The charge current falls and the voltage is kept constant at the maximum level Pulse Maintenance phase where the charger delivers a pulse if the battery voltage drops Charging varies between 95 and 100 The battery receives a pulse when the voltage reduces Keep the battery in good condition when not in use The charger can be connected for months BULK CHARGING TIME TEMPERATURE PROTECTION The charger is interna
5. d warranty DECLARATION OF COMPLIANCE Manufacturer CTEK SWEDEN AB Rostugnsvagen 3 SE 776 70 VIKMANSHYTTAN SWEDEN Tel 46 225 351 80 Declares under sole responsibility that the battery charger MULTI XS 3600 to which this declaration relates complies with the follow ing standards EN60335 1 EN 60335 2 29 following the provisions of directive 73 23 EEC amended by 93 68 EEC and EN 55014 1 EN 61000 3 3 EN 61000 3 2 EN 55014 2 following the provisions of directive 89 336 EEC amended by 92 31 EEC and 93 68 EEC Vikmanshyttan Sweden 2002 03 12 B rje Maleus Managing Director CTEK SWEDEN AB CTEK SWEDEN AB Rostugnsvagen 3 SE 776 70 VIKMANSHYTTAN SWEDEN Fax 46 225 307 93 www ctek se CCTEK 13840162_UK
6. le remove the cable from the chassis before removing the other cable 6 If the charger lamp and the maintenance charger lamp are flashing alternately the reason for this is due to e An interruption during charging due to a loose connection or because the battery has ceased to work The battery has become sulphated If the lamps flash for more than 30 minutes this indicates that the battery is dead and needs to be replaced e If there is an interval of more than 10 seconds between the flashes this indicates that the battery has a high self discharge rate and may need to be replaced SAFETY The charger is designed for charging 1 2 120 Ah lead acid batter ies Do not use it for any other purpose Always use safety goggles and turn your face away from the battery when turning it on and off When being charged batteries could emit explosive gases Prevent flames and sparks close to the battery Always provide for proper ventilation during charging e Avoid covering the charger Battery acid is corrosive Rinse immediately with water if acid comes into contact with skin or eyes Seek medical advice Never charge a frozen battery e Never place the charger on top of the battery when charging BATTERY TYPES AND SETTINGS The following recommendations should only be seen as guidelines Please consult the battery manufacturer for further instructions Mode 14 4V 0 8A ce This mode is normally used for lt 14 Ah
7. lly protected from becoming overheated The power reduces when the ambient temperature increases MAINTENANCE The MULTI XS 3600 does not need any specific maintenance Please note that dismantling the charger will cancel the warranty A defective power cord has to be replaced Keep your charger clean Wipe it with a soft tissue and mild cleaning liquid The charger must be disconnected for cleaning EQUIPMENT The MULTI XS 3600 is delivered with a set of battery leads with battery pole clamps Leads with eyelet terminals are available as accessory SPECIFICATION Voltage AC 220 240 VAC 50 60 Hz Output power is reduced at lower input voltage A perfect charge will still be achieved Current 0 6 Arms Starting Current lt 25A Back Current Drain 1 3mA Charging Voltage Nominal 12 V 14 4 V or 14 7 V Ripple Max 50 mV rms max 0 13 A Charging Current 3 6 Amax Ambient Temperature 20 C till 50 C Automatic reduction of power at increased ambient temperature Cooling Natural convection Charger type Three step fully automatic IUoUp with pulse maintenance mode Type of batteries All types of lead acid batteries Wet MF VRLA AGM and GEL Battery Capacity 1 2 till 120 Ah Dimensions 165 x 61 x 38mm LxWxH Insulation IP 65 Weight 0 5 kg Back Current Drain is what drains the battery if the charger is connected without the power cord connected Multi XS 3600 extremely low Back Current Drain is equal to

Download Pdf Manuals

image

Related Search

Related Contents

Bedienungsanleitung Serie 9500    Catalog    EE 2145230 Chapter 11 Power Distribution Systems  Bedienungsanweisung  Package Insert - Sekisui Diagnostics  Frigidaire FFEW2725PB Product Specifications Sheet  取扱説明書 - キッコーマン バイオケミファ  2014 Highland Ridge RV Owners Manual All Models  

Copyright © All rights reserved.
Failed to retrieve file