Home

USFM 100 Installation Guide

image

Contents

1. pd gt Extron Electronics HTERFACIAES EX WWITLDLHUPJES AMO CONTAC USFM 100 e Installation Guide IMPORTANT SAFETY INSTRUCTIONS Read all instructions before starting installation When using this accessory basic precautions should always be followed including the following WARNING Risk of Personal Injury Maximum setup load for the USFM 100 projector arm is 20 Ibs 9 1 kg AVERTISSEMENT Risque potentiel de blessure grave La charge maximum d installation pour le USFM 100 le bras du projecteur est 9 1 kg 20 Ibs SAVE THESE INSTRUCTIONS NOTE Refer to local building standards and codes to verify that the installation will meet the regulatory requirements Observe all local and national building and safety codes UL requirements and ADA accessibility guidelines WARNING Risk of Personal Injury and Property Damage Do not exceed specified weight limits of any component of the installation Follow the manufacturer s specifications and installation instructions AVERTISSEMENT Risque potentiel de blessure grave ou de dommages mat riels Ne d passez pas les limites de poids de n importe quel composant de l installation Suivez les sp cifications et les instructions d installation du fabricant The Extron USFM 100 is a mounting kit for suspending ultra short throw projectors from a wall The USFM 100 base plate enclosure is capable of mounting a PoleVault System switcher and its supplied power supply with suffic
2. 4 4 1 4 1 2 4 4 4 WARNING Risk of Personal Injury and Property Damage Before commencing installation the wall structure must be examined to determine if it is suitable for the proper installation and support of this product If needed the installer should reinforce the wall Drywalls should have a minimum thickness of 1 2 inch and a maximum thickness of 5 8 inch Improper installation of this product could lead to serious injury AVERTISSEMENT Risque potentiel de blessure grave ou de dommages mat riels Avant de commencer l installation la structure du mur doit tre examin e afin de d terminer si elle est appropri e pour l installation et la prise en charge correctes de ce produit Si n cessaire l installateur devra renforcer le mur Les murs en plaque de pl tre doivent avoir une paisseur minimum de 2 54 cm 1 2 inch et une paisseur maximum de 12 7 cm 5 8 inch Une installation non conforme de ce produit peut engendrer des blessures graves The location and type of wall where the USFM 100 is to be installed should be identified before starting installation This determines the installation method and the type of fasteners used to secure the plate to the wall Recommended Installation Tools e evel 24 inch e Ladder e Tape measure e Stud finder e Drill and drill bits e Phillips screwdriver e Allen hex wrench 5 64 size 1 Mount the Base Plate NOTE Before installation see the user manual for the display device
3. to determine the proper location and placement of the mount Take into consideration the projector lens offset screen size screen aspect and projected image throw distance See page 8 for the dimensions of the USFM 100 with the projector pipe and UPB 25 attached to aid in this determination a Atthe desired site use an edge to edge stud finder to locate the center of the wall studs wood or steel Mark each stud location Minimum joist size should be 2 inches by 4 inches ATTENTION Potential Damage to Property For secure installation it is required to attach the base plate to two wall studs using a minimum of four securing points Drywall toggles can be used for holes that are not aligned with studs see figure 3 This product is not intended to be mounted solely to drywall ATTENTION Risque de dommages mat riels Afin de s curiser l installation il est n cessaire de fixer la base a deux poteaux muraux en utilisant au moins 4 points de fixation Des chevilles bascules adapt es la cloison peuvent tre utilis es si les percements ne sont pas align s sur le support Ce produit n est pas concu pour tre mont directement sur une cloison s che b Hold and level the base plate against the wall Mark a minimum of four positions two top two bottom using either the mounting slots or the keyholes slots uppermost that are on the stud lines see the marks in figure 2 Where applicable mark the mounting holes on the w
4. all for drywall toggles USFM 100 Cutout for Marker for ue Base Plate Signal Cable Level Pilot Hole ue Access Signal Cables Exiting from Cutout Figure 2 Wall Mounting Features c If the cables are to be run behind the wall to the USFM 100 location mark the cutout area on the wall large enough for signal cables see inset in figure 2 d Remove the base plate and set it aside Cut out the marked area for cable access For drywall with wood studs i Drill inch 6 35 mm pilot holes at the marked stud locations ii Align the base plate mounting holes over the pilot holes and lightly secure with 5 16 inch lag screws and washers NOTE If using toggle screws for assembly follow the installation method steps A D shown in figure 3 A Grasp plastic handle collapse B Slide plastic washer down C Cut off plastic handle close D Hand screw in pan head bolt toggle and insert into wall into pilot hole to wall until 1 8 inch gap remains Figure 3 Steps for Toggle Assembly Installation iii Verify level and position and fully tighten down all the screws to secure the plate flush to the wall For drywall with steel studs i Drill a v inch 13 mm hole through the stud at each of the locations four recommended ii Insert the supplied toggles through the studs and lightly secure the plate using the four supplied 14 20 x 2 inch bolts and washers iii Verify level an
5. d position and fully tighten down all the bolts to secure the plate flush to the wall USFM 100 Installation Guide cont d 2 Mount the Switcher a Place the mounting plate flat on the switcher base with the two small raised tabs on top and the small securing tab over the front panel Align the two mounting holes in the switcher base with the corresponding holes on the mounting plate Secure the plate to the switcher using the two 4 40 x inch pan head screws b Secure the mounting plate and switcher to the base plate by aligning the two small tabs on the back of the mounting plate over the corresponding tabs on the base plate see figure 4 inset Slide the mounting plate and switcher down into place Secure it to the base plate by passing a 6 32x 4 inch screw up through the securing tab see figure 4 Tighten down the screw NOTE Mount the switcher with the rear panel uppermost for ease of cable connection see figure 4 USFM 100 Base Plate Side View Device Rear Panel Mounting Plate 2 4 40 x 1 4 Screws Securing Tab Run signal cables from the PoleVault input wallplates control device location and the speakers to the USFM 100 location Cables can be routed behind the walls through a surface raceway such as Wiremold 700 or 2400 or through conduit directly to the USFM 100 If running cable behind the walls Run all the cables from all the locations to the USFM 100 and through th
6. e access hole cut in step 1d Proceed to step 4 If using a surface raceway or conduit a Turn over the left or right USFM cover as needed and from the inside cut the most suitable marked raceway or conduit knockout for the cable to enter the USFM 100 Remove the knockout b Run the raceway or conduit from all locations to the marked entrance and attach to the baseplate c Run the cables through the raceway or conduit to the USFM 100 Raceway Option A p A Signal Cable Access Cutout Option Figure 5 Cabling Run Options 4 Cable the Switcher Connect the cables from the PoleVault wallplates control device MediaLink Controller speakers and optional accessories VoiceLift Page Sensor Kit to the rear ports of the switcher See the PVS 305SA Setup Guide for connection details 5 Attach the Boom Arm Power Supply and Projector a Hook the boom arm over the top rail on the base plate so that the tab on the arm see figure 6 inset is against the rail Secure the arm at the bottom with the two supplied 10 32 x 3 8 inch pan head screws and washers and at the top with the single 74 28 x inch screw A SS Screw SS SS RSS O LOS n P gt L S amp Ss lt i i amp A p Phillips Pan Head Screws Set Screw Figure 6 Hook Boom Arm Over Rail and Secure USFM 100 Installation Guide cont d Depending on the power supply used either e Secure t
7. ers over the installed USFM base plate and boom arm and secure with supplied screws USFM 100 Dimensions 2 20 34 40 5 59 cm 87 38 cm F C 2 C C y C 2 C b C 2 T 2 C y T LO E E E A 11 14 O 28 29 cm H gt gt gt 6 G i G 6 O O Base Plate front view 36 29 E 92 19 cm Tro T 2 74 Ue LATA HUELLA m 6 96 cm z E Abs B on ARAAAAAAAAAAAAAD BARARAAAAARARAR V 12 94 32 86 cm E AAA A A AAA RARAS Vu gEEUFUVEVEVV A 1 Base Plate with Plastic Covers 31 80 max li e077 cm Foie E 30 00 max a 76 20 cm 1 65 54 99 cm i 3 60 9 14 cm O o ON e Boom Arm top view 12 50 min 31 75 cm Dc I C Y AO G 3 Da 2C DG ESL 9 3 85 mp Gi Co C J EAN C C a 2C Ic Os O pe 31 80 To Wall 80 77 cm 21 65 54 99 cm 7 125 m E 8 18 cm L Be E Boom Arm side view 12 54 31 86 cm USFM 100 Installation Guide cont d Aligning the Projector When ali
8. gning the projector to the screen or wall display consult the projector manual for the relevant throw lengths See the images below for the dimensions of USFM 100 with the UPB 25 installed Page 7 shows the basic USFM 100 unit dimensions and the diagram below shows the installed unit dimensions L 31 80 max E Center of UPB 80 77 cm 2 ON COMI 30 00 max i 0 0 2 0 76 20 cm 0 5 08 m EM Lo a ry C O O matt i 8 18 13 26 cm m EE mm 12 54 31 86 cm Y 3 71 9 42 cm y 34 40 i 87 38 cm 9 95 amp _ 12315 5 60 12 15 edm Base Plate 30 86 cm 14 22 cm 30 86 cm Mounting Holes BN 0 20 0 51 cm Underside of LLS Underside of 27 78 cm Boom Arm 6 25 Boom Arm 15 88 cm 8 90 22 61 cm Extron Headquarters Extron Asia Extron China Extron Korea 1 800 633 9876 Inside USA Canada Only 65 6383 4400 86 21 3760 1568 82 2 3444 1571 Extron Europe Extron Japan Extron Middle East Extron India 31 33 453 4040 81 3 38511 7655 971 4 299 1800 91 80 3055 3777 2014 Extron Electronics All rights reserved All trademarks mentioned are the property of their respective owners WWW extron com 68 1838 01 Rev D 8 09 14
9. he power supply within the support end of the boom arm To do this pass the tie wraps through the holes on one side of the arm and then around the power supply see figure 7 left image Tighten the tie wraps The cables should then be easily and safely routed to the electrical outlet and to the switcher OR e Using the two 4 40 x inch pan head screws secure the power supply to the second device mounting bracket Secure the mounting plate and power supply to the base plate by aligning the two small tabs on the back of the mounting plate over the corresponding tabs on the base plate above the installed switcher see figure 7 right image Slide the mounting plate up into place Secure it to the base plate with a 6 32x 4 inch screw through the securing tab Tighten down the screw EI Mounting Brackets C DER Y PoleVault Switcher Figure 7 Secure the Power Supply in the Boom Arm or the Mounting Bracket Extend the boom arm to the appropriate projector throw distance and secure in the applicable slots with the four supplied 4 20 x Ya inch screws and washers NOTE Do not overtighten the screws Loosen the set screw located in the lower hole on the boom arm end and screw the threaded pipe up into the end of the arm A minimum of three turns is needed to safely secure the pipe in place Lock it in place by tightening down the set screw NOTE The upper hole on the boom ar
10. ient room remaining for installing additional devices and cable management It is designed to be used with the UPB 25 universal projector bracket supplied with the Extron WallVault system The USFM 100 has knockouts on all four sides that allow external raceways or conduits to be attached for cabling runs where necessary Extron USFM 100 Boom Arm Arm Cover top Arm Cover front Arm Cover buttom Plastic Enclosure Cover Figure 1 USFM 100 Parts USFM 100 Installation Guide cont d Hardware Included in the Kit Y4 20 x 2 inch pan head bolts 4 Base plate to wall installation Ya inch toggle assembly 4 Baseplate to wallinstallation___ inch metal washers 47 64 inch O D 8 Base plate to wall installation O 5 16 x 3 inch lag screws 4 Baseplateto wallinstallation___ 5 16 inch metal washers 11 32 inch I D 11 16 inch O D 4 Base plate to wall installation and boom arm 14 28 x 3 4 inch screw 1 Securingboom arm top 4 20 x 1 2 inch button screws 4 j Secuingboomarm exensio 10 32 x 3 8 inch pan head screws 10 32 x Y4 inch set screw 1 Securing projector pipe gt 4 ME 6 32 x inch button screws Securing covers for boom arm 10 Securing device mounting plates 6 32 x 1 2 inch button screws Securing plastic covers for enclosure Tie wraps Securing power supply wires 4 40 x inch pan head screws OA Securing switcher to plate Installation ty 4 4
11. m end is for attaching an optional seismic support wire Run the VGA and composite video cables from the switcher to the projector through the boom arm so that they exit down the projector mounting pipe NOTE Provide sufficient cable slack within the boom arm to allow for future arm length adjustment Referring to the UPB 25 User Manual screw the UPB 25 upper mounting plate onto the threaded pipe and attach the projector to the UPB 25 projector bracket Attach the projector bracket with projector installed onto the UPB 25 mounting plate and secure it Connect the output cables from the switcher any MLC control cables and the power cable to the projector CAUTION Electrical Shock That May Result in Injury Do not thread the projector power cable through the boom arm or mounting pipe Threading it through the arm or the pipe violates national electrical regulations ATTENTION Choc lectrique qui peut causer des blessures N enfilez pas le cable d alimentation du projecteur sur le support flexible ou le tuyau de montage L enfiler sur le support ou le tuyau enfreint les r glementations lectriques nationales 6 Complete the Installation a Switch on the display device control device and signal sources and configure the system Adjust the position and length of the boom arm as needed adjusting the UPB 25 to center the image When fully satisfied secure the arm and tighten down all the UPB 25 locking screws Place the cov

Download Pdf Manuals