1. It is not necessary to open the fixture before power supply Make the power supply before insert the luminary into installation box Power supply is solved simple with 1 5m cable Cord plug connections Symbol Pin Wire Colour Screw US L live brown yellow or brass N neutral blue silver a ground earth yellow green green 04 MAINTENANCE To tackle all Safety Information 01 Damage caused by inadequate cleaning or maintenance is not coveredby warranty Regular cleaning is demand dust dirt Order code Product name Maintenance policy Unplug mains before maintenance and at least 10 minutes cool off LL32 480 LL A3 SPOT 07 IN GROUND W Appliance do not illegal open or demount LL32 490 LL A3 SPOT 07 IN GROUND N Clean up dust only from outer surface f Use vacuum or dumpy duster warm water Accessories Before reinstalling to check failure free state no wet parts LL41 455 LL BOX SPOT IN GROUND If you have any question please contact support leaderlight sk
2. Leader Light s r o M Gorkeho 33 SK 052 01 Spisska Nova Ves Slovakia www leaderlight eu USER MANUAL LL A3 SPOT 07 IN GROUND W N LL32 480 LL33 485 COMPLIMENTS ON YOUR PURCHASE LEADER LICHT professional lighting products All dimensions are in millimeters S N O 165 290 V __V BOX IN GROUND Following items are included LL A3 SPOT 07 IN GROUND with 1 5m cable 1 pc LL BOX SPOT IN GROUND 1 pe User manual 1 pe Additional items needed Screws and washers Content 01 SAFETY INFORMATION 01 1 Risk of eyes damage 01 2 Protection from electric shock 01 3 Fire prevention 02 PRODUCT SPECIFICATION 02 1 Technical Specification 03 INSTALLATION 03 1 Unpacking 03 2 Physical installation 03 3 Connecting to AC power 04 MAINTENANCE ENVIRONMENT eS Do not throw away the appliance with the normal household waste at the end of its life but hand it in at an official collection point for recycling By doing this you help to preserve the environment MMxX Leader Light All right reserved 01 SAFETY INFORMATION ZN WARNING Carefully read before installing powering or servicing Nothing to do if anything misunderstand Installation can be done only by a qualified professional in accordance with relevant local codes 01 1 Risk of eyes damage A Do not look directly into LED lamps Do not look into light beam from a
3. distance of less than 40 cm 16 inches 01 2 Protection from electric shock A Shut down power before installation or maintenance Luminaries and recommended AC power supply must be installed by a qualified professional in accordance with relevant local codes Only acceptable source of AC power and frequency that complies with local building and electrical codes to use Do not use or do not connect the products if the power cable power plug or fixtures are any way damaged wet or if they are overheating Do not modify alter or attempt to service the LeaderLight appliance Doing so will void the warranty Before removing or installing any cover or part of appliance disconnect it from AC power Appliance always connect to earth eltech 01 3 Fire prevention A Follow all safety consideration Thermostatic switches or fuses never to bypass Device never shield Around the axis of the fitting 180 must be maintained space for cooling The fixture use only with original floor box figure 1 1 LEDs never direct cover with filters or other materials Allowing max ambient temperature is 40 C 104 F LL A3 SPOT 07 IN GROUND is not suitable for standard dimming 02 PRODUCT SPECIFICATION 02 1 Technical Specification Lamp type 7 x W N Acriche Lifetime Over 35 000 hrs Optic Standard 5 on request 25 40 60 Max input power 28W Power connection 220 240V 50 60Hz AC 1 5m cable On req
4. uest US version 100 120V Net weight 2kg IP eo Ambient temp Ta Maximum 40 C Cooling Conventional Materials and finish Powder painted aluminium RAL 9006 other colours on request Installation In ground mounting Acriche W White 6300 K _ N Neutral White 3000 K Edtion A 2010 03 INSTALLATION 03 1 Unpacking Unpack carefully This is electronic equipment and should be handled carefully Damaged delivered package or if are any mechanical parts broken it must be claim immediately by the transport company Photo pictures as evidence are valuable for future claim 03 2 Physical installation The floor box install in slot The fixture never input directly into the ground without any floor box Hairbreadth from combustible materials is 0 5m Installation in floor Cut out 150mm WM Connect the fixture to AC power supply and put the fixture in the box Fit the top of luminary with screws in the floor ee The installation box insert in floor WARNING py L The fixture never input directly into the ground without any floor box If you have any question please contact support leaderlight sk 03 3 Connecting to AC power To tackle all Safety Information 01 For protection from electric shock the device must be grounded earthed

Download Pdf Manuals

image

Related Search

Related Contents

BETOLEVEL 15  寸胴鍋用バイメタル温度計 取扱説明書  ビジランスヘモダイナミックモニター    Manual de instrucciones  WORX WG773E lawnmower  Student User Guide (updated 2.06.06)  MODE D`EMPLOI CONTRAT D`APPRENTISSAGE  Intel Server Platform SRKA4  Digitus PCI USB 2.0 card  

Copyright © All rights reserved.
Failed to retrieve file