DSO1060 User Manual

image

Contents

1. 2 3 The base of ALT Mag 4 The main time base The following describes the ALT Mag display The screen is divides into two parts The upper half displays the main waveform window and the lower half displays an expanded portion of the main waveform window This expanded portion of the main window is called the ALT Mag window Two blocks shadow the upper half The un shadowed portion is expanded in the lower half The TIME DIV amp C key control the size and position of the ALT Mag The symbol at the right bottom of the screen means the main time base and the symbol on the center 34 DSOIOOO SERIES HANDHELD SCOPEMETER bottom means the ALT Mag time X Y Format This format is useful for studying phase relationships between two signals Channel 1 in the horizontal axis X and channel 2 in the vertical axis Y EUH i AUTO l Figure 2 25 X Y display format The following modes or functions will not work in X Y format m Automatic Measurements m Cursor Measurements m REF and MATH Operations m Horizontal Position m Trigger Controls 35 USER S MANUAL 1060 1200 1500 1600 1600H Set Trigger System The trigger determines when the scope meter starts to acquire data and display a waveform When a trigger is set up properly it can convert unstable displays or blank screens into meaningful waveforms When the scope meter starts to acquire a waveform it collects enough data so that it can draw the waveform to
2. 57 CHAPTER 3 Using examples 61 CHAPTER 4 Multimeter 69 CHAPTER 5 Troubleshooting 80 CHAPTER 6 Specifications 81 CHAPTER 7 AppendiX c2 c S22 84 DSOIOOO SERIES HANDHELD SCOPEMETER General Safety Notice 1 Safety Terms and Symbols Terms in this manual These terms may appear in this manual WARNING Warning statements identify conditions or practices that could result in injury or loss of life CAUTION Caution statements identify conditions or practices that could result in damage to this product or other property Terms on the Product These terms may appear on the product DANGER indicates an injury hazard may be immediately accessible WARNING indicates an injury hazard may be not immediately accessible CAUTION indicates that a potential damage to the instrument or other property might occur Symbols on the Product These symbols may appear on the product A A S 7 Hazardous Refer to Protective Grounding Test Voltage Instuctions Earth Terminal Terminal Grounding of Chassis Terminal 2 General Safety Information Carefully read the following safety information in order to avoid any personal injury or damage on this product or any products connected with it Review the following safety precautions carefully before operate the device to avoid any personal
3. Amp x 100 Overshoot Measured over the entire waveform Middle Voltage of the 50 level from base to top Average voltage of a waveform CRMS The Root Mean Square voltage over the first cycle in the waveform Preshoot 56 DSOIOOO SERIES HANDHELD SCOPEMETER The Time Measurement menu table Width Measured of the first Negative pulse in the waveform Positive Duty Cycle Positive Pulse Width Period x 100 Duty l i Measured of the first cycle in waveform Negative Duty Cycle Negative Pulse Width Period x 100 Duty U Measured of the first cycle in waveform Delay 1 gt 2 4 The delay of rising time between channel 1 and channel 2 Delay 1 22 The delay of falling time between channel 1 and channel 2 NOTE The results of the automatic measurements will be displayed on the bottom of the screen Maximum 3 results could be displayed at the same time When there is no room the next new measurement result will make the previous results moving left out of Screen Cursor Measurement The screen displays two parallel cursors Move the cursors to make custom voltage or time measurements of the signal The values are displayed on the boxes below the menu Before using cursors make sure to set the Signal Source as the channel for measuring Press CURSOR to shows the cursor menu as the following The Cursor menu hace Tyne GoUFee Figure 2 60 The Cursor menu The Cursors menu table ON Turn on off the cursor measure
4. Figure 2 18 The External menu The External menu table Delete File To create afile EM To delete chosen file Go to the Storage menu page Display a Reference Waveform CH2 u 1 88 Figure 2 19 Reference display 1 Press M R button to show the reference waveform menu 2 Press F2 to select the reference channel CH1 CH2 or MATH 3 Press F4 to save REF 4 Press F5 to load an internal REF file 5 Press F1 button to turn on REF 31 USER S MANUAL 1060 1200 1500 1600 1600H NOTE The Reference function is not available in X Y mode Set Horizontal System The horizontal system changes the horizontal scale and position of waveforms The horizontal center of the screen is the time reference for waveforms Changing the horizontal scale causes the waveform to expand or contract with respect to the screen center Horizontal position changes the displayed waveform position relative to the trigger point Press HORI button to show the horizontal system menu The settings of this menu are listed in the following table The Horizontal Menu ALT Mad Haldaf f OFF Figure 2 20 The Horizontal menu The Horizontal Menu Table Y T Show the relative relation between vertical voltage and horizontal time I X Y Show CH1 value at X axis CH2 value at Y axis Time base Roll In Roll Mode the waveform display updates from right to left Pressing this button clears trigger offset and Reset moves the trigger point to the hor
5. Press CH1 F5 F4 ON to set up bandwidth limit to ON status It will reject the frequency component higher than 20M Hz The waveform is displayed as Figure 2 10 24 DSOIOOO SERIES HANDHELD SCOPE METER AUTO oe NETS s EI E T33 my Em 1 Figure 2 10 Turn BW limit On 6 Math Setting The mathematic functions include add subtract multiply division and FFT for Channel 1 and Channel 2 The mathematic result can be measured by the grid and the cursor The mathematic window is displayed as figure 2 11 The Math menu Page 1 2 MATH Enable Operate source Source B lk a B Figure 2 11 The Math menu The Math menu Page 2 2 MA TH m V alt Dir Invert Probe Wi Figure 2 12 The Math menu The Math menu setting table 25 USER S MANUAL 1060 1200 1500 1600 1600H _ Enable ON Turn on math OFF Turn off math Add source A and source B Subtract source B from source A Operate Multiply source B by source A Divide source A by source B Fast Fourier Transform ei Define CH1 or CH2 as source A CH1 Define CH1 or CH2 as source A Source B CH2 1 2 2 2 Coarse Set Voltage range coarsely Vadis Set Voltage range finely invert ON Invert the MATH waveform OFF Waveform display normal 1x Select one according the probe attenuation factor to ensure a correct vertical scale reading 2 2 Back to the previous menu page gt Add Subtraction Multiplication Divisi
6. pletely Notice To avoid superheat of battery during charging the environment temperature is not al lowed to exceed the permissible value given in technical specification Note No hazard will occur even connecting the charger for a long time e g during a whole weekend The instrument can automatically switch to slowly charging status Replacing the Lithium Battery Unit It is usually not required to replace the battery unit But when it is required to replace it only qualified personnel can carry out this operation and only use the same specification lithium battery 85 USER S MANUAL 1060 1200 1500 1600 1600H
7. Mode OFF S USER S MANUAL 1060 1200 1500 1600 1600H Shown as vertical line to measure the horizontal Type parameters Shown as horizontal line to measure the vertical parameters CH1 Source CH2 Select the measurement signal source MATH CusorA SelectCursorAor no Omen ee The scope meter measures the Y or X coordinate values of the cursors and the increments between the two cursors To do cursor measurements please do as the following steps 1 Turn on the cursor measurement Cursor 5Mode Manual Track Auto 2 Select channel Source for measurements by pressing soft button as Cursor Source CH1 CH2 MATH 3 Select the cursors type by pressing soft button as Cursor Type X or Y 4 Press F4 or F5 to select the Cursor A or Cursor B 5 Move the cursors to adjust the increment between the cursors The values will be automatically displayed on the right upper corner of screen when the cursor function menu is hidden or displaying other menus Comments of Cursor Measurements 1 Auto Cursor Mode The Auto Cursor Mode displays the cursors for the current measuring automatically See figure 2 61 2 Manual Cursor Mode In this mode the scope meter measures the Y or X coordinate increments between the two cursors See figure 2 62 1 Select menu Mode gt Manual 2 Select menu Type gt X Y to get the vertical or horizontal of Cursor A or Cursor B 3 Select menu Source gt CH1 CH2 MATH to
8. jacks The four circular jacks are used for voltage resistance mA range current and A range current inputs 3 Multi meter test lead 4 Scope Meter probes 5 Scope Meter input channels USER S MANUAL 1060 1200 1500 1600 1600H Function Check Perform this quick functional check to verify that your scope meter is operating correctly 1 Turn on the instrument Use the power adapter designed for your scope meter only Use a power source that delivers 100 to 240 VACRMS 50Hz Turn on the scope meter 2 Input a signal to a channel Set the attenuation switch on the probe to 10X and connect the probe to Channel 1 on the scope meter To do this m Align the slot in the probe connector with the key on the CH 1 BNC connector m Push to connect and twist to the right to lock the probe in place m Attach the probe tip and ground lead to the PROBE COMP connector Set the probe attenuation of the scope meter to 10X To do this push CH1 Probe 10X Figure 1 5 Set the probe Push the AUTO button Within a few seconds a square wave will display approximately 1 kHz 2 V peak to peak Turn off Channel 1 and turn on Channel 2 repeat steps 2 and 3 DSOIOOO SERIES HANDHELD SCOPEMETER To compensate probes Perform this adjustment to match the characteristics of the probe and the channel input This should be performed whenever attaching a probe to any input channel the first time From CH1 menu set the Probe atten
9. look like the following figure 4 6 Auto Figure 4 6 AC voltage Measurement Making a DC Current Measurement To measure a DC current which is less than 600 mA do the following 1 Press the A key and then DC appears at the screen The unit on the main reading screen is mA Press F2 to switch the measurement between mA and 10A 600mA is acquiescently 2 Insert the black lead into the COM banana jack input and the red lead into the mA banana jack input 3 Connect the red and black leads to the measured points and the DC current value of measured points will be displayed on the screen Then the screen will look like the following figure 4 7 To measure a DC current which is larger than 600 mA do the following To measure a DC current which is larger than 600 mA do the following 1 Press the A key and then DC appears on the screen The unit on the main reading screen is mA 2 Press F2 key to switch to 10A measurement the unit on the main reading screen is A 3 Insert the black lead into the COM banana jack input and the red lead into the 10A 74 DSOIOOO SERIES HANDHELD SCOPE METER banana jack input 4 Connect the red and black leads to the measured point and the DC current value of the measured point will be displayed on the screen 5 Press F2 to return to 600 mA measurement Then the screen will look like the following figure 4 8 Auto DC f T O NXN N mA Figure 4 7 DC current Measurement for 600
10. mA Making an AC Current Measurement To measure an AC current which is less than 600 mA do the following 1 Press the A key and then DC appears on the screen The unit on the main reading screen is mA and mA will display on the bottom of the screen press F2 to switch the measurement between mA and 10A 600mA is acquiescently 2 Press the F1 key once and AC will display on the bottom of the screen 3 Insert the black lead into the COM banana jack input and the red lead into the mA banana jack input 4 Connect the red and black leads to the measured points and the AC current values of measured points will be displayed on the screen Then the screen will look like the following figure 4 10 To measure an AC current which is larger than 600 mA do the following 1 Press the A key and then DC appears on the screen The unit on the main reading screen is mA 2 Press F2 key to switch to10A measurement the unit on the main reading screen is A 15 USER S MANUAL 1060 1200 1500 1600 1600H Figure 4 8 DC Current Measurement for 10A EEn m lit DSOIOOO SERIES HANDHELD SCOPE METER Figure 4 9 AC Current Measurement for 600 mA 3 Press the F1 key once and AC will display on the bottom of the screen 4 Insert the black lead into the COM banana jack input and the red lead into the 10A banana jack input 5 Connect the red and black leads to the measured point and the AC current value of the measured point will be displayed on the s
11. menus and perform basic measurements Connecting the Meter Use the 4 mm safety banana jack inputs for the Meter functions 10A mA COM V O C Multimeter Operation Window l 3 h jJ J k 4 NCC 5 KL mV b in E l i f 8 9 Figure 4 1 Multimeter operation window Description 1 Battery electric quantity indictor 2 Measurement mode indictors DC Direct electric measurement AC Alternating electric measurement 69 USER S MANUAL 1060 1200 1500 1600 1600H 3 The symbol of Mutimeter current mode 4 Manual Auto range indictors among which the MANUAL refers to measuring range in manual operation mode and Auto means the measuring range in automatic operation mode The reading value of measurement The bar graph indictor DC or AC Measurement mode control Absolute relative magnitude measuring control The sign expresses the absolute magnitude measuring control and A represents the relative magnitude measuring control 9 Manually or automatically measuring range control Operating the Multimeter If you are in the scope mode window press DMM OSC key the scope meter will switch to the multimeter mode window Then the screen will display the measure mode window that was in use the last time before you quit multimeter measure When you switch to the multimeter measurement the first time the default measure mode is DC voltage mode Measuring Resistance Values To measure a resistance do
12. of the trigger level of the two channels will be displayed on the upper right of the screen See the ALT screen in figure 2 29 Press TRIG F1 ALT button to show the ALT trigger menu as the following table The ALT Trigger menu Type Edge Page 1 2 Mace Channel Type slope ee wb E Figure 2 30 The ALT trigger menu The Alternative menu table Type Edge Page 1 2 Channel CH1 Set trigger for CH1 CH2 Set trigger for CH2 Tvpe Edge Set Edge Pulse Trigger as the trigger yp Pulse type Eie Rising Trigger on rising edge P Falling Trigger on falling edge 38 DSOIOOO SERIES HANDHELD SCOPE METER 1 2 gt MEE Go to the next menu page CH1 upas s Figure 2 29 ALT Mode Screen Description The Slope type of CH1 Trigger The horizontal trigger position of CH1 Trigger The trigger level value of CH1 The trigger position of CH2 The trigger level value of CH2 The time base value of CH1 The trigger level of CH1 The trigger level value of CH1 The horizontal trigger position of CH2 10 The time base value of CH2 11 The trigger level of CH2 12 The trigger position value of CH2 CO OO N O Om SS Q N gt 39 USER S MANUAL 1060 1200 1500 1600 1600H 13 The volt value of CH1 14 The volt value of CH2 The ALT Trigger menu Type edge Page 2 2 HF Reject SKS Figure 2 31 The ALT Trigger menu The Alternative menu table ni edge Page 2 2 Setting De
13. page The Utility menu table Page 3 4 Menu Setting Description 3 4 Back to the previous menu page Infinite 5MIN Set the shut down time 30MIN Shut Down Select languages Language More languages may be added in later firmware versions Calibrate Calibrate the scope meter 3 4 The Utility menu table Page 4 4 Setting Description 4 4 el Back to the previous menu page Configure No Save Not save the system configuration Save Save the system configuration Update x Update the system System Info ws Show the information of the system 47 USER S MANUAL 1060 1200 1500 1600 1600H 4 4 Ek Go to the first previou menu page Calibrate The calibration adjusts the internal circuitry to get the best accuracy Use these functions to calibrate the vertical and horizontal systems For maximum accuracy at any time run this calibration if the ambient temperature changes by 5 C or more Before running this procedure do these steps 1 Disconnect any probes or cables from all channel inputs otherwise failure or damage to the scope meter may be occurred 2 Push the Utility button and select Calibrate The calibration screen is shown as in Figure 2 44 Calibration CH racessina Calibration CH2 Mot Ye Figure 2 44 The Calibration Screen NOTE The scope meter must have been working or warm up at least 30 minutes before running calibration to get best accuracy The scope meter will calibr
14. the following 1 Press the R key and then resistance measurement window appears on the screen 2 Insert the black lead into the COM banana jack input and the red lead into the V O C banana jack input 3 Connect the red and black test leads to the resistor The resistor value value is shown on the screen in Ohm Then the screen will look like the following figure 4 2 Making a Diode Measurement To make a measurement on the diode do the following 1 Press the diode key and a diode symbol appears at the top of the screen 2 Insert the black lead into the COM banana jack input and the red lead into the VIQIC banana jack input 3 Connect the red and black leads to the diode and the voltage value of the diode is displayed on the screen in voltage value Then the screen will look like the following figure 4 3 70 DSOIOOO SERIES HANDHELD SCOPE METER dad H 29 1HBH 11x x i Figure 4 3 Diode Measurement 71 USER S MANUAL w w L 1 1060 1 200 1 900 1600 1600H Making On off Test To perform an On off test do the following 1 Press the On off key and then On off indictor appears on the top of the screen 2 Insert the black lead into the COM banana jack input and the red lead into the V Q C banana jack input 3 Connect the red and black leads to the test point If the resistance value of the tested point is less than 30 Q you will hear beep sound from the test tool Then the screen will look like
15. the following figure 4 4 DX NT figure 4 4 Making a Capacitance Measurement To measure a capacitance do the following 1 Press the C key and a capacitor symbol appears on the top of the screen 2 Insert the black lead into the COM banana jack input and the red lead into the V O C banana jack input 3 Connect the red and black leads to the capacitor and the capacitance value is displayed on the screen in HF or nF Then the screen will look like the following figure 4 5 ra DSOIOOO SERIES HANDHELD SCOPE METER Juul H s P iI Figure 4 5 Capacitance Measurement Making a DC Voltage Measurement To measure a DC voltage do the following 1 Press the V key and DC appears at the top of the screen 2 Insert the black lead into the COM banana jack input and the red lead into the V O C banana jack input 3 Connect the red and black leads to the measured point and the measured point volt age value is displayed on the screen Making an AC Voltage Measurement To measure the AC voltage do the following 1 Press the V key and DC appears at the screen 2 Press the F1 key and AC appears at the screen 3 Insert the black lead into the COM banana jack input and the red lead into the V O C banana jack input 4 Connect the red and black leads to the measured points and the AC voltage value of measured points will be displayed on the screen r3 USER S MANUAL 1060 1200 1500 1600 1600H Then the screen will
16. 0MHz DSO1060 5 8ns DSO1200 1 7ns Rise Time DSO1500 0 7ns DSO1600 0 58ns DSO1600H 0 58ns Input Impedance Resistance 1M Capacitance 15pF DSO1060 10mv div to 5v div DSO1200 10mv div to 5v div Input Sensitivity DSO1500 2mv div to 10v div DSO1600 2mv div to 10v div DSO1600H 2mv div to 10v div Input Coupling AC DC with Ground Level Indicator Memory Depth 32k at single channel 16k at dual channel Maximum Input 400V DC AC Peak Horizontal DSO1060 150MSa s DSO1200 250MSa s Sampling DSO1500 500MSa s DSO1600 1GSa s DSO1600H 2GSa s Equivalent Sampling 50GSa s Time Base Precision 50ppm 81 USER S MANUAL 1060 1200 1500 1600 1600H DSO1060 5ns div 1000s div DSO1200 2ns div 1000s div Time Base Range DSO1500 1ns div 1000s div DSO1600 1ns div 1000s div DSO1600H 1ns div 1000s div Trigger DSO1060 Edge Pulse Width Alternative DSO1200 DSO1500 DSO1600 DSO1600H Edge Pulse Width Alternative Vedio X Y Mode X Axis Input Channel 1 Y Axis Input Channel 2 Phrase Shift Max 3 degree Cursors and Measurement Voltage Vpp Vamp Vmax Vmin Vtop Vmid Vbase Vavg Vrms Vcrms Preshoot Overshoot Time Frequency Rise time Fall Time Postive Width Negative Width Duty Cycle Delay 1 gt 2 Delay 1 2 Manual Track Auto Measure Modes Math Addition Subtraction Multiplication Divi sion FFT 15 Waveforms and setups Meter Mode Maximum Resolution 6000 Counts D
17. Get the Cursor Source 4 Select Cursor A or Cursor B to adjust the increments between Cursor A and Cursor B 5 Get the values between Cursor A and Cursor B delt x is the time between Cursor A and Cursor B 1 delt x is the frequency between Cursor A and Cursor B 3 Track Cursor Mode In Track Cursor Mode the Cursor A and Cursor B move together with the selected waveform See figure 2 63 58 DSOIOOO SERIES HANDHELD SCOPEMETER Tess m LECH WEIN USER S MANUAL 1060 1200 1500 1600 1600H Figure 2 62 The Manual Cursor Mode Do as the following steps 1 Select menu Mode Manual 2 Select menu Type gt X Y to get the vertical or horizontal of Cursor A or Cursor B 3 Select menu Source gt CH1 CH2 MATH to Get the Cursor Source 4 Select Cursor A or Cursor B to adjust the increments between Cursor A and Cursor B 5 Get the values between Cursor A and Cursor B delt x is the time between Cursor A and Cursor B 1 delt x is the frequency between Cursor A and Cursor B 3 Track Cursor Mode In Track Cursor Mode the Cursor A and Cursor B move together with the selected waveform See figure 2 63 Figure 2 63 Track Cursor Mode Please do the following steps 1 Select menu Mode Track 2 Select Source for measurements Select options as followings Cursor A 2CH1 CH2 Cursor B gt CH1 CH2 3 Select Cursor A or Cursor B Move the Select Cursors to adjust the increments between the Cursors 4 Get the values between Curso
18. Hantek Hantek Electronic co Ltd No 7 zhuzhou road huite industry city QingDao China C DSOIOOO SERIES HANDHELD SCOPEMETER 1060 1200 1500 1600 1600H USER S MANUAL GC Ws eri CH S l i y eue LEE www hantek com cn HANDHELD SCOPEMETER DSOIOOO SERIES Is a AN zi L s O Ys LU We USER S MANUAL 1060 1200 1500 1600 1600H Content e LE A Iert 3 Digital Scope Meters 5 CHAPTER 1 Getting Start 6 General Check 6 User s lnterface 6 Input Connections 11 Function Check 12 To compensate probes 13 To display a signal automatically 15 Using the Scope Meter 15 CHAPTER 2 Operating Scope 18 Set Vertical System 18 Set Horizontal System 32 Set Trigger System 36 Save Recall Waveforms and Setups 42 Sii FUNCUO s TTL 46 Signal Measurement 55 Cursor Measurement
19. MM Testing Modes Voltage Current Resistance Capacitance Diode amp Continuity Maximum Input Voltage AC 600V DC 600V Maximum Input Current AC 10A DC 10A 82 DSOIOOO SERIES HANDHELD SCOPEMETER Display 240 Vertical X 320 Horizontal Dots Interface Power source Line Voltage Range AC 100V 240V 50Hz 60Hz DC Input 8 5 VDC 1500mA Battery Power Installed 6 hours Li ion Battery MECHANICS 245 x 163 x 52 mm Weight 1 2Kgs Other GND Reference Scope meter and Multimeter Independence 83 USER S MANUAL 1060 1200 1500 1600 1600H apter 7 Appendix Appendix A Accessories 1 Probex2 1 5m 1 1 10 1 Passive Probes 2 A Power Adapter that fits the standard of destination country 3 AUser s Guide 4 A User Registration Form 5 AUser Warranty Card Appendix B Warranty Hantek Co Ltd warrants its products mainframe and accessories in materials within the warranty period During the period concerned Hantek guarantees the free replacement or repair of products which are approved defec tive To get repair service or obtain a copy of the whole warranty statement please contact with your nearest sales and service office Hantek does not provide any other warranty items except the one being provided by this summary and the warranty statement The warranty items include but not being sub jected to the hinted guarantee items related to tradable characteristic and any particular purp
20. Probe ensure correct vertical scale reading Set the vertical display position back to middle window 1 2 Go to the next menu page o gt 2 2 Back to the previous menu page 1 Coarse Set Voltage range coarsely VON Fine Set Voltage range finely invert ON Turn on the invert function OFF Turn off the invert function D ON Turn on the BW Limit EI Turn off the BW Limit 2 2 Back to the previous menu page L 1 Change Volt DIV It is the default setting of Volts Div in a 1 2 5 step sequence from 10mV div 20mV div 50mV div to 1V div 5 V div or 10V div The Volt DIV will be displayed in the status bar on the bottom of the screen Figure 2 2 Channel Volt Div Press CH1 Volt Div Coarse Fine to Set Volt range 19 USER S MANUAL 1060 1200 1500 1600 1600H 2 Set Channel Coupling With CH1 taken for example input a sine wave signal containing a dc offset Press CH1 Coupling AC to set AC coupling It will pass AC component but block the DC component of the input signal The waveform is displayed as Figure 2 3 CH1 EBENE Enable Coupling Figure 2 3 Waveform Display Press CH1 Coupling DC to set DC coupling It will pass both AC and DC components of the input signal The waveform is displayed as Figure 2 4 20 DSOIOOO SERIES HANDHELD SCOPE METER CH BH Enable Coupling Probe Figure 2 4 Waveform Display Press CH1 gt Coupling gt GND to set GND coupling it disconnects the
21. Pulse width m Multiple Language User Interface m Pop up menu makes it easy to read and easy to use m Built in multi language help system m Easy to use file system supports Multi Language characters file name input m Selectable 20 MHz bandwidth limit USER S MANUAL 1060 1200 1500 1600 1600H CHAPTER 1 Getting Start This chapter covers the following topics m General Check m Functional Check m he User Interface m input Connections m To compensate probes m To display a signal automatically m Using the Scope Meter General Check When you have got a new DSO1000 series scope meter it is suggested that you should perform a general inspection on the instrument according to the following steps m Check the shipping container for damage Keep the damaged shipping container or cushioning material until the contents of the shipment have been checked for completeness and the instrument has been checked mechanically and electrically m Check the accessories Accessories supplied with the instrument are listed in Accessories in this guide If the contents are incomplete or damaged please notify our distributor at your local area or the overseas sales dept m Check the instrument In case there is any mechanical damage or defect or the instrument does not operate properly or fails performance tests please notify our distributor at your local area or the overseas sales dept User s Interface The first thing to do wit
22. S CRMS LL Figure 2 58 The Measure menu The measure menu Page 5 5 Measure Oyvreshoot FPreshoot 2 5 Figure 2 59 The Measue menu The scope meter provides 22 auto measurements Vpp Vmax Vmin Vtop Vmid Vbase Vamp Vavg Vrms Vcrms Overshoot Preshoot Freq Period Rise Time Fall Time Width Width Duty Duty Delay 1 gt 2 4 Dealy 1 gt 2 12 voltage and 10 timing measurements USER S MANUAL 1060 1200 1500 1600 1600H The Measure menu table A CH1 Select CH1 or CH2 as source CH2 channel for measurement T Voltage Select to measure voltage ype Time parameter Meas All ON Turn on all measurement result OFF Turn off all measurement result Clear ws Clear measurement result on screen 1 2 gt aa Go to the next menu page The Voltage Measurement menu table Pk to Pk Peak to peak Max Min Measured over the entire waveform Voltage of the absolute maximum level Maximum Measured over the entire waveform Voltage of the absolute minimum level Minimum Measured over the entire waveform Voltage of the statistical maximum level Top Measured over the entire waveform Voltage of the statistical minimum level Base Measured over the entire waveform Amp Base Top Amplitude Measured over the entire waveform The Root Mean Square voltage over the entire waveform Positive Overshoot Max Top Amp x 100 Measured over the entire waveform Negative Overshoot Base Min
23. arcsine C D 8 must be in the range of 0 Tr 2 or 311 2 21r if the main axis of the ellipse is between and lll quadrant If the main axis is at I and IV quadrant 6 must be in the range of 11 2 Tr or rr 377 2 USER S MANUAL 1060 1200 1500 1600 1600H Example 3 The FFT Cursor Measurements FFT measurement includes Amplitude measurement Vrms or dBVrms and the Frequency measurement Hz Do these steps as followings 1 Press the key CURSOR to show Cursor menu 2 Select Mode gt Manual to enter the Manual Cursor Mode window 3 Select Type gt X Y select the Cursor Type to X or Y 3 Select Source gt MATH FFT operation in the Manual Cursor Mode window 4 Drag the Cursor to the point of interest See the FFT Measurement Cursor Type Y in figure 3 3 Emm 25 2dBE Im m TI DEA SHE Tim Figure 3 3 FFT Measurement Cursor Type Y See the FFT Measurement Cursor Type X in figure 3 4 64 DSOIOOO SERIES HANDHELD SCOPE METER LI He ini TT IT ET TI Tele Figure 3 4 FFT Measurement Cursor Type X Example 4 The Pass Fail Test The Pass Fail Test is one of the enhanced special functions of the Scope Meter By this function the Scope Meter could compare the input signal with the established waveform mask If the waveform touches the mask a Fail signal occurs Otherwise the test passes When needed a programmable output can be used for external automatic
24. ate in Wet Damp Conditions m Do not operate in an Explosive Atmosphere m Keep Product Surfaces Clean and Dry DSOIOOO SERIES HANDHELD SCOPE METER Digital Scope Meters DSO1000 Series digital scope meters offer exceptional waveform viewing and measurements in a compact lightweight package DSO1000 series is ideal for production test field service research design education and training involving applications of analog circuit tests and troubleshooting Product features m Dual Channel Bandwidth 60MHz DSO1060 200MHz DSO1200 500MHz DSO1500 600MHz DSO1600 600MHz DSO1600H m Maximum real time sampling rate 150MSa s DSO1060 250MSa s DSO1200 500MSa s DSO1500 1GSa s DSO1600 2GSa s DSO1600H m Memory depth 32K points Single Channel 16K points Dual Channels m Color TFT LCD 320x240 pixels resolution m USB storage and printing supports firmware upgrade via USB interface m Adjustable waveform intensity more effective waveform viewing m One touch automatic setup ease of use AUTOSET m 15 Waveforms 15 setups supports CSV and bitmap format m 22 Automatic measurements m Automatic cursor tracking measurements m Waveform recorder record and replay dynamic waveforms m User selectable fast offset calibration m Built in FFT function Frequency Counter m Pass Fail Function m Addition Subtraction Multiplication and Division Mathematic Functions m Advanced trigger types include Edge
25. ate parameter of vertical system CH1 CH2 48 DSOIOOO SERIES HANDHELD SCOPE METER Pass Fail The Pass Fail function monitors changes of signals and output pass or fail signals by comparing the input signal is within the pre defined mask Press Utility Pass Fail to go to the following menu The Pass Fail menu Page 1 2 Enable Source OUTPUT Operate b us Figure 2 45 The Pass Fail menu The Pass Fail menu Page 2 2 Stop Output HE s Mask Figure 2 46 The Pass Fail menu The Pass Fail menu table Page 1 2 Enable ON Turn on Pass Fail test OFF Turn off Pass Fail test Source EB a Select Pass Fail test on CH1 EB a Select Pass Fail test on CH2 Output Fail Output when Fail condition detected Pass Output when Pass condition detected Fail Beep Output and Beep when Fail condition detected Pass Beep Output and Beep when Pass condition detected Operate Stop Pass Fail test stopped press to run Start Pass Fail test running press to stop The Pass Fail menu table Page 2 2 re Back to the previous menu page USER S MANUAL 1060 1200 1500 1600 1600H Stop ON Stop test when output occur output OFF Continue test when output occur 2 2 Back to the previous menu page Mask setting Press Utility Pass Fail Mask Setting to go to the following menu The Mask menu Page 1 2 Vertical Horizontal _ Location _ LESSE 16 Div5 MEINEN Internal Ve Figure 2 47 The Mask menu The Mask
26. control applications The output is built in as a standard feature and is optically isolated Do the steps as followings 1 Press the key Utility to enter the Utility menu 2 Press the key F5 in the panel to enter the page 2 4 3 Select the Pass Fail in the Utility menu to enter the Pass Fail menu 4 Select Enable to ON to turn on Pass Fail Select Source CH2 the input source select Stop Output to OFF or ON in Page 2 2 of Pass Fail menu 5 Create the Pass Fail Mask Change the Vertical or Horizontal value by click the up or down key in the panel to set the div of the vertical or horizontal values Select Create or Save or Load button if you need 6 Select Operate to Start in Pass Fail menu to start the Pass Fail function See the Pass Fail window in figure 3 5 65 USER S MANUAL 1060 1200 1500 1600 1600H Figure 3 5 The Pass Fail Window Example 5 Reduce the noise on a signal See the signal with random noise in figure 3 6 To reduce random noise do the following steps 1 Set the Probe and the channel attenuations to x10 2 Connect the signal to the Scope Meter to display a stable wave 3 Reduce the noise Select the Acquire Mode in Acquire menu If there is noise within the signal and the waveform looks too wide in this case choose average acquisition In this mode the waveform will be thin and easy to observe and measure Use the Average following the steps 1 Select Acquire in the Utility menu to enter
27. creen 6 Press F2 to return to 600 mA measurement Then the screen will look like the following figure 4 10 TP Figure 4 10 AC Current Measurement for 10A Taking a Relative Measurement A currently measured result relative to the defined reference value is displayed in a rela tive measurement The following example shows how to take a relative measurement At first it is required to acquire a reference value 1 Press the R key 2 Insert the black lead into the COM banana jack input and the red lead into the V O C banana jack input 3 Connect the red and black test leads to the resistor The resistor value is shown on the screen in Ohm 4 When the reading leveling off press F1 key and then IZA is displayed on the top of Ig USER S MANUAL 1060 1200 1500 1600 1600H the screen The saved reference value is displayed beside N Then the screen will look like the following figure 4 11 Manual Figure 4 11 Relative Measurement Selecting Automatic Manual Range Adjustment The default range mode of the instrument is automatic range Suppose you are using the DC voltage mode to switch to the manual range perform the following steps 1 Press F3 key to enter the manual range mode and then Manual is displayed on the top of the screen 2 Under the manual range mode the measuring range is increased by a stage when pressing F4 key each time and when reaching the highest stage it jumps to the lowest stage by pressin
28. eforms to be selected for display The reference function will be available after saving the selected waveform to non volatile memory Press M R button to display the Reference waveform menu Select menu Enable gt ON to enter reference function window The reference function window is displayed in figure 2 15 5H ml Figure 2 15 The reference function window Internal Press M R REF Internal and go to the following menu REF menu when using internal memory 29 USER S MANUAL 1060 1200 1500 1600 1600H Enable Source acatian Figure 2 16 The Internal menu REF menu table when using internal memory Enable ON Turn on REF OFF Turn off REF CH1 Select channel1 as REF channel Source CH2 Select channel2 as REF channel MATH Select MATH as REF channel Internal Select memory location in scope Location External Select memory location out scope REF menu table when using external memory Enable ON Turn on REF OFF Turn off REF Sauce CH1 Select channel1 as REF channel CH2 Select channel2 as REF channel Internal Select memory location in scope Location External Select memory location out scope 1 2 gt Go to the next menu page External Press M R REF External and go to the following menu The External REF menu Page 1 2 Enable cure Location OFF GHI Figure 2 17 The External menu The External REF menu Page 2 2 30 DSOIOOO SERIES HANDHELD SCOPEMETER Delete Fie Load
29. g F4 key once again 3 Press F3 key to switch back to the automatic range mode and then Auto is displayed on the top of the screen Attention capacitance measurement without manual range mode 78 DSOIOOO SERIES HANDHELD SCOPE METER Manual Range Figure 4 12 The Manual Mode window 79 USER S MANUAL 1060 1200 1500 1600 1600H Chapter 5 Troubleshooting 1 The scope meter cannot start 1 Check the power cable connection 2 Ensure the power switch is turned on 3 After the above inspection restart the scope meter 4 If the problem still remains please contact us for help 2 The measurement result is 10 times higher or lower than the value expected Check if the probe attenuation is the same as the channel attenuation 3 The waveform is displayed on the screen but is not stable under the scope meter mode 1 Check the Trigger Source and notice if it is set to the channel in use 2 Check the Trigger Type 4 When select the average sampling in the sampling mode or select a long dis play time in the display mode under the scope meter the display speed is slow It is normal in the above case 5 After the Acquisition is set to Averages or Display Persistence is set ON the waveform refreshes slowly It is normal in these settings 80 DSOIOOO SERIES HANDHELD SCOPEMETER apter 6 Specifications Vertical DSO1060 60MHz DSO1200 200MHz Bandwidth DSO1500 500MHz DSO1600 600MHz DSO1600H 60
30. h a new scope meter is to know its front panel This chapter helps to be familiar with the layout of the keys and how to use them Read this chapter carefully before further operations Front Panel Figure 1 1 The buttons not only allow you to use some of the functions directly but also bring up the manual keys on the screen which enable the access to many measurement features associated with advanced functions mathematics and reference or to run control features DSOIOOO SERIES HANDHELD SCOPEMETER m s WAR Enable Coupling Probe Figure 1 1 Scope Meter Front Panel USER S MANUAL 1060 1200 1500 1600 1600H Hl IIXRII HB II SIE AH OL Ueuplina lim sai RE su Ca 1m dome L3 u l nh eom om mm 9 ee Figure 1 2 Front Panel Description Description 1 LCD Display 2 F1 F5 Sets or switch options for the menu 3 Arrow Keys 4 Hori Shows Horizontal menu 5 TRIG Shows Trigger menu 6 Level Adjust the trigger level DSOIOOO SERIES HANDHELD SCOPEMETER 7 RUN STOP key for running or stopping the operation 8 AUTO Be used for auto setting under the oscilloscope operation mode 9 TIME DIV Decrease or Increase the time base 10 CH2 Shows the CH2 menu VOLTS Decrease or Increase the voltage div CH1 Shows the CH1 menu M R Shows the Math or REF menu DMM Buttons The DMM control buttons DMM SCOPE Switch DMM or Scope fu
31. h setting up the pulse width condition Press TRIG F1 Pulse button to show the pulse trigger menu as the following table The Pulse Trigger Menu Page 1 2 ade SOUrCE when Setting E SEN Figure 2 27 The Pulse Trigger Menu The Pulse Trigger Menu Page 2 2 m Sweep HF Reject zn Figure 2 28 The Pulse Menu The Pulse Trigger Table Page 1 2 Ge Define CH1 or CH2 as trigger signal Pulse width more than Pulse width less than Pulse width equal to Pulse width more than Pulse width less than Pulse width equal toTo select pulse condition Setting Set required pulse width 1 2 37 USER S MANUAL 1060 1200 1500 1600 1600H The Pulse Trigger Table Page 2 2 Z Back to the previous menu page Acquire waveform even no trigger occurred Sweep Acquire waveform when trigger occurred When trigger occurs acquire one waveform and then stop SCH Reject high frequency signals Set the trigger level to the center of the signal Back to the previous menu page Note The Pulse width adjust range is10ns 10s When the condition is met it will trigger and acquire the waveform ALT Alternative Trigger Setting When alternative trigger is on the trigger sources come from two vertical channels This mode can be used to observe two non related signals You can choose two different trigger modes for the two vertical channels The options are as follows Edge Pulse Slope and video The info
32. injuries or damages to the device and any products connected to it To avoid potential hazards use the device as specified by this user s manual only m To Avoid Fire or Personal Injury m Use Proper Power adapter Use only the power cord specified for this product 3 USER S MANUAL 1060 1200 1500 1600 1600H and certified for the country of use m Connect and Disconnect Properly Do not connect or disconnect probes or test leads while they are connected to a voltage source m Connect and Disconnect Properly Connect the probe output to the measurement device before connecting the probe to the circuit under test Disconnect the probe input and the probe reference lead from the circuit under test before disconnecting the probe from the measurement device m Observe All Terminal Ratings To avoid fire or shock hazard observe all ratings and markings on the product Consult the product manual for further ratings information before making connections to the product m Use Proper Probe To avoid shock hazard use a properly rated probe for your measurement m Avoid Circuit or Wire Exposure Do not touch exposed connections and components when power is on m Do Not Operate With Suspected Failures If suspected damage occurs with the device have it inspected by qualified service personnel before further operations m Provide Proper Ventilation Refer to the installation instructions for proper ventilation of the device m Do not oper
33. input signal The screen displays as Figure 2 5 21 USER S MANUAL 1060 1200 1500 1600 1600H IIIHIIIIRIT TIIIFEIIIBI Figure 2 5 Waveform Display 3 Set Probe Attenuation The scope meter allows adjusting the probe attenuation scale factor correspondingly in the channel operation menu in order to comply with the probe attenuation scale The attenuation factor changes the vertical scaling of the scope meter so that the measurement results reflect the actual voltage levels at the probe tip To change or check the probe attenuation setting press the CH1 or CH2 button according to which channel in using Toggle the Probe soft button to match the attenuation factor of the probe This setting remains in effect until changes again Enable Coupling Probe Figure 2 6 Probe Setting 4 Invert a waveform The displayed waveform reverses 180 degrees relatively to the ground potential Press CH1 or CH2 F5 F3 to turn on off the Invert 22 DSOIOOO SERIES HANDHELD SCOPEMETER 5 Set Band Width Limit USER S MANUAL 1060 1200 1500 1600 1600H With CH1 taken for example input a signal containing high frequency component Press CH1 F5 F4 OFF to set up bandwidth limit to OFF status The scope meter is set to full bandwidth and passing the high frequency component in the signal The waveform is displayed as Figure 2 9 BLUTO Ge Bees T99 moll on CH1 NINH Figure 2 9 Turn BW limit Off
34. it to change function setting USER S MANUAL 1060 1200 1500 1600 1600H CHAPTER 2 Operating Scope The end user should know how to determine the system setup from the status bar of a Scope Meter This chapter will detail the scope meter function of the test tool m Set Vertical System m Set Horizontal System m Set Trigger System m Save and Recall waveforms and setups m Utility Function m Measure Signal m Cursor Measure Set Vertical System Each channel of Scope meter has its own independent operation menu and it will pop up after pressing CH1 or CH2 button The settings of all items in the menu are shown in the table below To make vertical CH1 and CH2 settings do the following 1 Press the CH1 or CH2 button and then the function menu appears at the bottom of the screen 2 Select and press key from F1 to F5 keys to make different settings Now you can find the menu that looks like the following figure 2 1 The CH1 menu Page 1 2 Enable Coupling Prone Reset The CH1 menu Page 2 2 M LI I B w In YE rt VAT L TI It Figure 2 1 The CH1 Menu The following table describes the channel menu 18 DSOIOOO SERIES HANDHELD SCOPEMETER Enable ON Turn on Channel OFF Turn off Channel AC The dc component in the input signal is blocked Coupling DC The ac and dc components of the input signal are allowed GND Disconnect the input signal Select one according to the probe attenuation factor to
35. izontal center of the screen ON Turn on ALT Mag Holdoff ON Turn on the Holdoff time OFF Turn off the Holdoff time 1 TIME DIV Use this button to select the horizontal time div scale factor for the main 32 DSOIOOO SERIES HANDHELD SCOPE METER TIME DIV Figure 2 21 The TIME DIV button 2 POSITION Press this button to adjust the horizontal position of all channel waveforms The resolution of this control varies with the time base POSITION Figure 2 22 The POSITION button 3 2 1 F a a 1 SUR III IIEHHTrI It ii I l lH dH l lilii C EF EE CES 4 Figure 2 23 The horizontal Time base marks Marks Indicator 1 The current waveform window s position in the memory 2 The trigger position in the memory 3 The trigger s horizontal offset according to the center of the window 4 The horizontal time base main time base 5 The trigger position in the current waveform windows ALT Mag The ALT Mag is a magnified portion of the waveform window Use ALT Mag to locate and horizontally expand part of the main waveform window for a more detailed higher 33 USER S MANUAL 1060 1200 1500 1600 1600H horizontal resolution analysis of signal The ALT Mag time base setting cannot be set slower than the main time base setting Figure 2 24 ALT Mag Mode Description 1 Wave to be horizontally expanded
36. lay back mode Storage Select storage mode OFF Turn off all recorder function source GH Select record source channel Source CH2 lt 1 1000 gt Set number of record frames 51 USER S MANUAL 1060 1200 1500 1600 1600H Start Record stopped press to Start recording Operate Stop Press to stop recording 1 2 gt Go to the next menu page The Record menu table 2 2 2 2 HET lt 4 Back to the previous menu page lt 1 00ms 1000s gt Set time interval between record frames Play back Play back the recorded waveforms The Play back menu Page 1 2 Mode perate ais Gi Interval Figure 2 51 The Play back menu The Play back menu Page 2 2 Start Frame Cur Frame End Frame m ame ame Id Frame I La Figure 2 52 The Play back menu The Record menu table Page 1 2 Operate Start Play stopped press to Start playback Stop Press to stop playing Repeat ON Set repeat play mode or not OFF lt 1 00ms 20s gt Setinterval time to play back The Record menu table Page 2 2 52 DSOIOOO SERIES HANDHELD SCOPE METER 2 2 Back to the previous menu page lt a Start Frame lt 1 1000 gt Set start frame lt 1 1000 gt Select current frame to be played lt 1 1000 gt Set End frame 2 2 c Back to the previous menu page Storage Store recorded waveforms to non volatile memory according to the setup frames The storage menu Page 1 2 Made Start Frame End Fra
37. ls input Connect a signal to the channel 1 input 1 Connect a signal to the scope meter 2 Press AUTO The scope meter may change the current setting to display the signal It will automatically adjust the vertical and horizontal scaling the trigger coupling type position slope level and mode settings Using the Scope Meter This part provides a step by step introduction to the scope functions The introduction does not cover all of the capabilities of the scope functions but gives basic examples to show how to use the menus and perform basic operations Turn on the scope meter Connect scope meter to AC power via a power adapter The scope meter can still work with built in Li ion battery even without AC power supply Turn the scope meter on by pressing down the power on off key The instrument then performs Self checking after power on The welcome picture will display on the screen when the system finishes Self checking The scope meter is powered up in its last setup configuration USER S MANUAL 1060 1200 1500 1600 1600H Hantek HAND HELD SCOPEMETER _ DSO1060 www hantek com cn Figure 1 6 The Login window Menu Operation The following example shows how to use the tools menus to select a function as shown in the following figure pa 6 6008 s L aeu m am m P EfTTTTITIT it lil TODO G me i we CHI 5 BQ EE TT Time 500 6 CHA Enable Coupling Probe Lov T
38. lt T gt WE aka Figure 1 The Menu DSOIOOO SERIES HANDHELD SCOPEMETER 1 Press the MENU ON OFF key to display the Function Menu on the bottom of the screen and the corresponding optional settings on the bottom Press MENU ON OFF again to hide the Function Menu 2 Choose one key from F1 to F5 and press it to change function setting Set up the vertical system 1 Change the vertical setup and notice that each change affects the status bar differently m Change the vertical sensitivity wie or button and notice the change in the status bar 2 Move the signal vertically m The N button moves the signal vertically Also notice that the channel symbol on the left side of the display moves in conjunction with the button To set up the horizontal system 1 Change the time base m The or button changes the time base in a 1 2 5 step sequence and displays thevalue in the status bar 2 Move signal horizontally m The lt or gt button moves displayed signal horizontally on waveform window It sets the trigger point position Set up the trigger system 1 Change the trigger Level m The AA orX7 button changes the trigger level The trigger level value is displayed at the top right of the screen and a line is displayed showing the location of the trigger level 2 Change the trigger setup and notice these changes in the status bar m Press TRIG button in the key panel Choose one key from F1 to F5 and press
39. lyze correlation of data of two channels Lissajous diagram is displayed in the screen when you use X Y Plot which enables to compare frequencies amplitudes and phases of counterpart waveform against the reference waveform This makes it possible to compare and analyze frequency amplitude and phase between the input and output Do these steps as followings 1 Set the probe attenuation to x10 Set the switch to x10 on the probes 2 Connect the CH1 probe to the input of the circuit and connect the CH2 probe to the output of the circuit 3 Click the key AUTO on the panel 4 Adjust the vertical scale and offset to display approximately the same amplitude signals on each channel 5 Select Time Base gt X Y format in Horizontal menu The Scope Meter will display a Lissajous pattern representing the input and the output characteristics of the circuit 6 Adjust the scale and offset of the horizontal and vertical to a desirable waveform display The following picture shows a typical example 7 Apply the Ellipse Method to observe the phase difference between the two channels See Signal in X Y Format in figure 3 2 A AUTO coo Ar CH1 Ha AR Time SB BELIZ Figure 3 2 Signal in X Y Format Instruction of the Ellipse Method 62 DSOIOOO SERIES HANDHELD SCOPE METER signal must be centered in X Sin8 A B or C D where 0 phase shift in degrees between the two signals From the formula above 0 tarcsine A B or t
40. me Location m b s Figure 2 53 The Storage menu The storage menu Page 2 2 Figure 2 54 The Storage menu The storage menu Page 1 2 lt 1 1000 gt Set first frame to be saved Frame 1 1000 Set end frame to be saved Location mema Set up Store location External The Storage menu when the save to Internal memory Page 2 2 Setting Description Sae Save recorded waveform to internal memory location Load DENEN Recall recorded waveform from internal memory location 53 USER S MANUAL 1060 1200 1500 1600 1600H gt Back to the Utility menu page The Storage menu when the save as external memory Page 2 2 Create File DEM Create a new file Delete File BE Delete a selected file Load Recall recorded waveform from external memory location Language DSO1000 series scope meters have multi language user menu choose as your desire Press Utility Language to select the language 54 DSOIOOO SERIES HANDHELD SCOPE METER Signal Measurement Press the MEAS button to display the menu of the automatic measurements settings The measure menu Page 1 5 Measure Source Type eas All Clear up Voltage Figure 2 55 The Measure menu The measure menu Page 2 5 Measure Fk to Pk Maximum mu HS maj Figure 2 56 The Measure menu The measure menu Page 3 5 Measure Middle 75 Figure 2 57 The Measure menu The measure menu Page 4 5 Measure den A Amplitude FM
41. menu Page 2 2 Figure 2 48 The Mask menu The Mask setting menu table Page 1 2 Vertical __ Set vertical clearance to the waveform 0 04div 4 00div Horizontal __ Set horizontal clearance to the waveform 0 04div 4 00div Create _ Create a test mask according to the above clearance Internal Store created test mask into internal External memory Location External 1 2 gt Go to the next menu page The Mask setting menu table Page 2 2 When the save as internal memory 2 2 Back to the previous menu page lt a Save Store created test mask into internal memory 50 DSOIOOO SERIES HANDHELD SCOPE METER load Recall mask setting file from internal memory o gt Back to the previous menu page The Mask setting menu Page 2 2 When the save as external memory Setting Save Go to save menu same as REF save menu Led Recall mask setting file from external memory Waveform Recorder Waveform recorder records input waveforms from CH1 and CH2 with a maximum record length of 1000 frames Press Utility Record Setting to go to the following Waveform recorder Record the waveforms with specified interval The Recorder menu Page 1 2 Mode Source End Frame Operate Figure 2 49 The Recorder menu The Recorder menu Page 2 2 Interval c mz Figure 2 50 The Recorder menu The Record menu table Page 1 2 Record Select record mode Play back Select p
42. nction MENU ON OFF Turn on off the menu SAVE RECALL Shows SAVE or RECALL menu MEAS Shows Measurement menu UTILITY Shows Utility menu CURSOR Shows Cursor menu POSITION Adjust the horizontal trigger position Display screen 1 2 3 1 f 8 WW m Ei 2 60 U cm 9 22 10 21 11 r mam aui penn gend 20 MERE EOD pum res gew E G DI ETH DH DH EH e 13 19 aE IE 1 GAME ind Pros Ti 5 Erabi Casing EU 1T Na 16 Figure 1 3 USER S MANUAL 1060 1200 1500 1600 1600H LCD Display screen Description CO OO N O Om Q N gt 11 12 CH2 waveform Shows the time base Shows the menu title The menu CH1 CH2 Shows the coupling Shows the voltage div CH2 mark CH1 mark Shows the trigger position in current waveform window Shows running status Shows delay time Shows location of the current waveform in the memory Shows the trigger position in the memory Shows the trigger mode Shows the trigger source Shows the trigger level Shows the power The center of current waveform window 10 CH1 waveform The trigger level symbol The grid DSOIOOO SERIES HANDHELD SCOPEMETER Input Connections See the following Figure 1 4 Figure 1 4 Input Connections Description 1 The power adapter is supplied for AC power supply and ad ey recharging 2 Multi meter input jacks including four circular banana
43. ng on the source signal 2 To reduce random noise and aliases components in repetitive or single shot events set the oscilloscope acquisition mode to average 3 To display FFT waveforms with a large dynamic range use the dBVrms scale The dBVrms scale displays component magnitudes using a log scale FFT Window The scope meter provides four FFT windows Each window is a trade off between frequency resolution and amplitude accuracy It depends on the desired measurement and the source signals characteristics to determine the window to use Use the following guidelines to select the best window The FFT Window table Best frequency resolution and Transients or bursts the signal worst magnitude resolution This levels before and after the is essentially the same as no event are nearly equal Equal window amplitude sine waves with fixed frequencies Broadband random noise with a relatively slow varying spectrum Rectangle 28 DSOIOOO SERIES HANDHELD SCOPEMETER Better frequency poorer Sine periodic and narrow band Hanning magnitude accuracy than random noise Transients or Rectangular Hamming has bursts where the signal levels Hamming slightly better frequency before and after the events are resolution than Hanning significantly different Best magnitude worst frequency Single frequency waveforms to Blackman U U l resolution Find higher order harmonics 8 REF Reference Waveforms are saved wav
44. ngs and can be recalled at anytime by Memory location Specify the memory location to save recall the waveforms and setups Load Recall saved waveforms setups and default settings Save Save waveforms and setups NOTE 1 Select save stores not only the waveforms but also the current scope meter 2 The oscilloscope can store 15 settings permanently and can restore at anytime 45 USER S MANUAL 1060 1200 1500 1600 1600H Utility Function Press the Utility button to show the menu of the settings in the Utility system The Utility menu Page 1 4 Sound NI T B AME c lud Figure 2 40 The Utility menu The Utility menu Page 2 4 Record ACQUIre Figure 2 41 The Utility menu The Utility menu Page 3 4 eOhutcdaowrn La HUUaUE Calibrate Calibrate 34 Figure 2 42 The Utility menu The Utility menu Page4 4 Configure Update system info ay mai Mo Save uhi Figure 2 43 The Utility menu The Utility menu table Page 1 4 Sound ON Turn beeper sound on off OFF E C ON Turn on Frequency Counter OFF Turn off Frequency Counter Display w Show Display menu page ON Turn on the multimeter OFF Turn off the multimeter 46 DSOIOOO SERIES HANDHELD SCOPEMETER 1 4 GZ mE Go to the next menu page The Utility menu table Page 2 4 Setting Description 2 4 Back to the previous menu page 1 Pass Fail Go to Pass Fail menu page 2 4 gt Go to the next menu
45. on and FFT In the Math function use the addition subtraction multiplication division and FFT to operate and analyze the waveform The multiplication function window is displayed in figure 2 13 7 FFT The FFT Fast Fourier Transform process converts a time domain signal into its frequency components mathematically FFT waveforms are useful in the following applications m Measure harmonic content and distortion in systems m Characterize noise in DC power supplies m Analyze harmonics in power lines 26 DSOIOOO SERIES HANDHELD SCOPEMETER m Analyze vibration CHI z HHIL Figure 2 13 The multiplication The FFT menu Page 1 2 Enable operate SOUrCE VV pd The FFT menu Page 2 2 atale Display 2 Figure 2 14 The FFT menu The FFT menu table Enable ON Turn on FFT OFF Turn off FFT 27 USER S MANUAL 1060 1200 1500 1600 1600H source je Define CH1 or CH2 as FFT source Source CH2 Rectangle Hanning Hamming Blackman 1 2 Go to the next menu page om Window Select window for FFT 2 2 Back to the previous menu page po Scale Vrms Set Vrms as vertical unit dBVrms Set dBVrms as vertical unit Displa Full Display waveform in full screen ES Split Display waveform in split screen 2 2 gt Back to the previous menu page Note 1 Signals that have a DC component or offset can cause incorrect FFT waveform component magnitude values To minimize the DC component choose AC Coupli
46. ose Hantek will not take any responsibility in cases regarding to indirect particular and ensu ing damage Appendix C Maintenance General Care Do not store or leave the instrument in where the LCD display will be exposed to direct sunlight for long periods of time CAUTION To avoid damage to the instrument or probes do not expose them to sprays liquids or solvents Cleaning If this instrument requires cleaning disconnect it from all power sources and clean it with a mild detergent and water Make sure the instrument is completely dry before recon necting it to a power source To clean the exterior surface perform the following steps 1 Remove loose dust on the outside of the instrument and probes with a lint free cloth Take care to avoid scratching the clear plastic display filter 2 Use a soft cloth dampened with water to clean the instrument NOTICE To avoid damage to the surface of the instrument or probes do not use any abrasive or chemical cleaning agents Storage of Scope meter If the test tool is to be stored for a long time it is required to charge the lithium battery before storage Charging the scope meter The lithium battery is possibly not charged when delivery To make the battery with enough electric quantity it must be charged for 4 hours the test tool must be turned off y 84 DSOIOOO SERIES HANDHELD SCOPEMETER during charging The battery can supply power for 6 hours after being charged com
47. r A and Cursor B delt x is the time between Cursor A and Cursor B 1 delt x is the frequency between Cursor A and Cursor B delt y is the voltage between the Cursor A and Cursor B 60 DSOIOOO SERIES HANDHELD SCOPEMETER Chapter 3 Using examples Example 1 Simple Measurement To acquire and display a signal please do the steps as followings 1 Connect signal to CH1 by using probe 2 Press the key AUTO on key panel The Scope Meter set the vertical horizontal and triggers controls at the best status automatically Also you can adjust the controls to meet your measurements to optimize the waveform display To measure the frequency and Vpp you can do these steps as followings 1 Press the key MEAS Select Source gt CH1 and select Type Voltage then press the key F5 and then press the key F2 to make a Pk to Pk test The Vpp value will display on the bottom of the waveform interface 2 Press the key MEAS select Source CH1and select type gt Time then Press the key F5 and then press the key F2 to make a Frequency test The Frequency value will display on the bottom of the waveform interface 3 Click the item Clear in the Measure menu To clear the measurements on the waveform interface See the measurements in the figure 3 1 Time 1 HE LI1S Figure 3 1 The Vpp and Freq measurement Window 61 USER S MANUAL 1060 1200 1500 1600 1600H Example 2 The Application of the X Y Operation X Y Plot acts to ana
48. scription EM Back to the previous menu page HF Reject Reject high frequency signals or not OFF 60 Set the trigger level to the center of the signal am Back to the previous menu page The ALT Trigger menu Type Pulse Page 1 2 Mace Channel Type hen E b S Figure 2 32 The ALT Tirgger menu The Alternative menu table Trigger Type Pulse Page 1 2 Channel CH1 Set trigger mode for Channel 1 CH2 Set trigger mode for Channel 2 EdgePulse Set Edge Pulse Trigger as the trigger type Pulse width more than Pulse width less than Pulse width equal to Pulse width more than Pulse width less than Pulse width equal toTo select pulse condition 40 DSOIOOO SERIES HANDHELD SCOPE METER 1 2 cc MEE Go to the next menu page The ALT Trigger menu Type Pulse Page 2 2 Setting HF Reject PIN dem UTE OFF al b Figure 2 33 The ALT Trigger menu The Alternative menu table Trigger Type Pulse Page 2 2 2 2 Back to the previou menu page Setting Set the width of the pulse HF Reject Reject high frequency signals or not OFF 56 Set the trigger level to the center of the signal 2 2 S Back to the previous menu page Term interpretation m Auto This sweep mode allows the scope meter to acquire waveforms even when it does not detect a trigger condition If no trigger condition occurs while the scope meter is waiting for a specific period as determined by the time ba
49. se setting it will force itself to trigger When forcing invalid triggers the scope meter cannot synchronize the waveform and the waveform seems to roll across the display If valid triggers occur the display becomes stable on the screen Any factor results in the un stability of waveforms can be detected by Auto Trigger such as the output of Power supply NOTE When horizontal control is set more than 50 ms div Auto mode allows the oscilloscope to capture without trigger signal m Normal The Normal mode allows the scope meter to acquire a waveform only when it is triggered If no trigger occurs the scope meter keeps waiting and the previous waveform if any will remain on the display m Single 41 USER S MANUAL 1060 1200 1500 1600 1600H In Single mode after pressing the RUN STOP key the scope meter waits for trigger While the trigger occurs the scope meter acquires one waveform then stop Save Recall Waveforms and Setups Press the Save Recall button the interface menu for settings shows as follows The Save Recall Menu Table Store or recall waveform Store or recall instrument setups Create or delete bit map files Create or delete CSV files Recall factory setups Internal s Go to menu for internal memory operation External BEEN Go to menu for external memory operation Wave The Wave menu Type r External Figure 2 34 The Wave menu The Wave menu table ena Go to menu for in
50. ternal memoryoperation Exemd Go to menu for external memoryoperation Setup The Setup menu Type arg NUM NX Figure 2 35 The Setup menu The Setup menu table 42 DSOIOOO SERIES HANDHELD SCOPE METER Internal W Go to menu for internal memoryoperation External w s Go to menu for external memoryoperation Bitmap The Bitmap menu Type Figure 2 36 The Bitmap menu The Bitmap menu table Ete Go to menu for external memoryoperation CSV The CSV menu Type Figure 2 37 The CSV menu The CSV menu table Exemd Go to menu for external memoryoperation Factory The Factory menu Type The Factory menu table USER S MANUAL 1060 1200 1500 1600 1600H ded Recall factory setups or files Internal Memory Press SAVE RECALL Internal to go to the following menu IN 01 N Internal l Set up the location of files in internal memory IN_15 N boad Recall waveform files and setup files from the internal memory location Save waveform files and setup files to the Save internal memory location External Memory Press SAVE RECALL External to go to the following menu Delete File ws Delete file Recall waveform and setup from USB storage Load device File system as following 44 DSOIOOO SERIES HANDHELD SCOPEMETER j DS B Dip Delete File M Load Figure 2 39 File System Factory The scope meter has default setti
51. the Acquire menu 2 Select Mode to Average then Press F2 to change the Averages form 2 to 128 to switch the number of averages that best eliminates the noise from the displayed waveform 3 Select Mode to Normal to cancel this function See signal after reducing random noise in figure 3 7 66 DSOIOOO SERIES HANDHELD SCOPEMETER Figure 3 7 Signal after reducing random noise 67 USER S MANUAL 1060 1200 1500 1600 1600H Example 6 Capture a Single signal To capture a single event it needs to gather some pre test knowledge of the signal in order to set up the trigger level and slope correctly For example if the event is derived from TTL logic a trigger level of 2 Volts should work on a rising edge Do these steps as followings 1 Set the probe and the channel attenuations to 1 10 2 Press the key TRIG to show the Trigger menu 3 Select Mode gt Edge Set Source to CH1 and Slope to Rising Set Sweep to Single 4 Adjust the Volts Div and the time base in a proper range for the signal 5 Drag the trigger level sign on the waveform display screen 6 When the trigger conditions are met data appears on the display representing the data points that the Scope Meter obtained with one acquisition 68 DSOIOOO SERIES HANDHELD SCOPE METER CHAPTER 4 Multimeter About this chapter This chapter provides an introduction to the multimeter functions of Protek1000 Series The introduction gives guides to show how to use the
52. the left of the trigger point The scope meter continues to acquire data while waiting for the trigger condition to occur After it detects a trigger the scope meter continues to acquire enough data so that it can draw the waveform to the right of the trigger point Trigger Modes The scope meter provides seven trigger modes Edge Pulse and Alternative Edge An edge trigger occurs when the trigger input passes through a specified voltage level in the specified slope direction Pulse Use this trigger type to catch pulses with certain pulse width Alternative Trigger on non synchronized signals Edge Trigger Setting An edge trigger determines whether the oscilloscope finds the trigger point on the rising or the falling edge of a signal Select Edge trigger Mode to trigger on rising edge falling edge or rising amp falling edge Press TRIG F1 Edge button to show the edge trigger menu as the following table The Edge trigger menu Made SOUrce olope oweep AF Reject Figure 2 26 The Edge trigger menu The Edge Trigger Table Define CH1 or CH2 as trigger signal Rising l Falling Trigger on rising edge or falling edge 36 DSOIOOO SERIES HANDHELD SCOPEMETER Acquire waveform even no trigger occurred Acquire waveform when trigger occurred When trigger occurs acquire one waveform then stop Pulse Trigger Setting Pulse trigger occurs according to the width of pulse The abnormal signals can be detected throug
53. uation to 10X press CH1 Probe 10X Set the switch to 10X on the probe and connect it to CH1 of the scope meter When using the probe hook tip insert the tip onto the probe firmly to ensure proper connection Attach the probe tip to the Probe compensator connector and the reference lead to the ground pin Select CH1 and then press AUTO 2 Check the shape of the displayed waveform Correctly Compensated USER S MANUAL 1060 1200 1500 1600 1600H Over compensated Under Compensated 3 If necessary use a non metallic tool to adjust the trimmer capacitor of the probe for the flattest square wave being displayed on the scope meter 4 Repeat if necessary WARNNING To avoid electric shock while using the probe be sure the perfection of the insulated cable and do not touch the metallic portions of the probe head while it is connected with a voltage source DSOIOOO SERIES HANDHELD SCOPEMETER To display a signal automaticall The scope meter has an Auto feature that automatically sets up the scope meter to best display the input signal Using Auto requires signals with a frequency greater than or equal to 50 Hz and a duty cycle greater than 1 Press the AUTO button the scope meter turns on and scales all channels that have signals applied and it selects a time base range based on the trigger source The trigger source selected is the lowest numbered input that has a signal applied The scope meter has two channe