Home
        50098-677 Rev A
         Contents
1.  into the control drawer  phematic system and connection  block nozzles     e Turn the system on using the ON OFF switch  Confirm  the system powers up to the ENDODRY    Storage and  Drying System home screen     To verify the ENDODRY Storage and Drying System is operational     refer to the document 50098 679   INSTALLATION CHECKLIST   to document and verify proper system installation     Refer to the User Manual for the entry of operator and endoscope  information     MEDIVATORS Customer and Technical Support Toll Free  Phone   1 800 444 4729   FAX  1 866 421 7696    wil Medivators BV Cantel Medical Asia Pacific Pte  Ltd  Medivators Inc  Beijing Representative Office    i  Medivators Inc   E MI   D IVA   O RS 14605 28th Avenue North Sourethweg 11 1A International Business Park Room 1801  Floor 18th  Tower A   Od Minneapolis  MN 6422 PC Heerlen  05 01 Singapore 609933 Beijing Marriott Hotel  Office Building    A Cantel Medical Company 55447 4822 USA The Netherlands Tel   65 6227 9698 No  7  Jianguomen South Avenue   Tel   1 763 553 3300 Tel   31 45 5 471 471 Fax   65 6225 6848 Dongcheng District  Beijing 100005 China  Fax   1 763 553 3387 Fax   31 45 5 429 595 Tel   86 10 65204039    www medivators com       2015 Medivators Inc  All rights reserved  50098 677 A    
2. INSTALLATION calender E  INSTRUCTIONS ENDODRY    Storage  amp  Drying System  This document provides guidance in the installation of the ENDODRY Storage and Drying System   Ba READ THE ENTIRE DOCUMENT BEFORE STARTING INSTALLATION    APPLICABLE DOCUMENTS   e ENDODRY System Site Requirements   e ENDODRY System Pre Installation Checklist   e ENDODRY System Installation Verification Checklist  e ENDODRY Storage and Drying System Users Manual    TOOLS REQUIRED  e 4mm hex wrench    e 8mm hex wrench    CUSTOMER REQUIREMENTS    e The customer is responsible for preparing the facility site prior to the ENDODRY Storage and Drying System arrival  including  all required electrical and air supply needs     INSTALLATION OF ENDOSTORE DRYING CABINET    IMPORTANT  Remove the drying cabinet and provided accessories from its packaging with care  Please inspect the equipment  upon arrival  checking for any evidence of damage during shipping     Inspect the equipment to ensure all supplied parts are complete       QTY   Description  1   ENDODRY Storage and Drying System    barcode reader with cable and holder   2x barcode readers for pass thru models     1   power cord   1      air lines with quick connector  1   Users manual   1   LAN cable             Move the ENDODRY Storage and Drying System to its final location     Check the level of the cabinet front to back and left to right using   a bubble level  If leveling is required  remove the four small white  plugs in each corner of the base as 
3. shown  Use a 4mm hex wrench  to adjust the level  Replace the plugs when complete     IMPORTANT  For optimal user safety and operation  it is  recommended that the ENDODRY Storage and Drying System always  be placed directly on the floor and not on an elevated platform type  device        z  M EDIVATORS    A Cantel Medical Company           f                  Vor   ffnen  OEDS Netzstecker  ziehen          MEDIVATORS    and ENDODRY    are trademarks of Medivators Inc     Install the supplied barcode scanner  s   and the holder s      The barcode scanner holder s  attach  to the top of the cabinet as shown   Use the supplied screws to attach   Tighten the screw with a 8 mm hex  wrench     Note  Two barcode scanners and holders  are Supplied with the pass thru cabinet   The barcode scanners on the pass thru  cabinet are side dependent  If they initially  do not function properly  swap the barcode  scanners     e Connect the power supply  the air line and optional  LAN connection to the panel located on the top  of the system  The wall outlet should be within the  operators reach for easy unplugging     NOTE  Take care to clean the cabinet before operation   Disinfect all contact surfaces with an approved surface  disinfectant     Use only surface disfectants appropriate for medical  devices  Chemicals need to be compatible with polyethylene  terephthalate  polyvinal cholride  PVC   aluminum and stainless  steel  For cleaning  only use a lint free cloth  Avoid saturating  soluton
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
産んだらダメですか?  TDC 33 DMX LED light effect User manual - Bax  do Manual em Português  Bulletin d`abonnement et sommaire ( 120 ko)  Le plan marketing  Manual (Adobe PDF)  施工説明書 床下耐火金庫  Télécharger Programme de la saison 2014-2015  HP Notebook PC User's Manual  INSTRUÇÃO PARA INSTALAÇÃO DO RELÉ PISCA    Copyright © All rights reserved. 
   Failed to retrieve file