Insallation instruction
Contents
1. Cleaning Inspection and cleaning of floor drains are required every 6 months at the latest or as needed in shorter time intervals Odour seal must be checked in case of requirement For cleaning purposes the odour seal has to be dismantled Drain body and odour seal can be cleaned with fat dissolving rinsing water e g water with commercial dishwashing agent The sealing ele ment at the odour seal must also be cleaned Hood and stand pipe of the stainless steel odour seal can be dismantled for cleaning pur poses Installation of odour seal must be carried out as per above mentioned instructions Replenish the drain body with water again fig 6 Fig 6 Connection of sealing gt Apply sealing to the fixed flange adhering flange of the drain body in accordance with the pertinent standards and regulati ons gt With the compression sealing flange the sealing has to be clamped with the loose flange subsequently The contact pressure of the nuts must be adapted to sealing used refer to manufacturer s indications and the nuts must be tightened evenly across The max torque is 20 Nm gt Top section Extension Upper part intermediate section Upper part intermediate section with lateral inlet Detail 1 Fig 7 Service Line Tel 49 0 36965 819 0 Fax 49 0 36965 819 361 ACO Haustechnik 0152 87 58 B Assembly of upper part intermediate section Variant CR Conn
2. 0 00 230 230 een 9190 10 00 425 8 230 a Connection to the pipeline Floor drain 9390 10 00 425 8 230 gt Drain socket DN 70 Variant CR f 9292 13 00 230 230 in connection with h element included in scope o c9 en trhose E 9192 13 00 425 8 230 supply suitable for connection to SML pipe ae 9392 13 00 425 3 230 without hose element suitable for connection to plastic 9296 10 00 230 E 230 pipe Floor drain 9396 13 00 230 230 gt Drain socket DN 100 DN 150 single body 9496 10 00 230 230 suitable for SML pipe DN 100 DN 150 9496 13 00 230 230 9495 30 00 300 a When connecting to other pipe types use relevant transition DN 100 f 9495 35 00 300 Industrial drains elements DN 150 9595 30 00 480 8 300 9595 35 00 480 8 300 9795 30 00 480 8 300 E Grout drain body in recess core bore Service Line Tel 49 0 36965 819 0 Fax 49 0 36965 819 361 Information on odour seal The drain should not be used for disposal of solid matters risk of blockage The odour seal must be fitted following connection of the drain to the drainage system at the latest Installation of bell shape odour seal with roller ring ACO Floor drains Variant CR DN 70 DN 100 with inclination 90 The bell shape odour seal must be rolled in without lubricant the roller ring must be placed into the lower groove Place odour seal vertically on drain socket fig 2 and roll in The rollin
3. ACO Haustechnik User manual 0152 87 58 B 02 2011 edition ACO Floor drains Variant CR DN 70 DN 100 and DN 150 This user manual contains important information It Core bores must be handed on to the end user who has to keep it Stainless steel floor drains in a safe place with without bell shape odour seals Note Prior to installation check the components for their proper condition do not fit damaged parts General installation information For completion of drain body relevant top and intermediate sections for point drainage or channels for line drainage from our current catalogue range have to be used For the installation of top sections relevant user manuals are attached to the components F ees p Fig 1 shows floor drain Variant CR DN 100 Inthe case of use in floors with fire resistance class e g F90 the special instructions for fire resistance floor drains Nominal Designation Art no Oa b Oc have to be observed when installing the drain body refer to width mm mm mm assembly instructions of fire protection kit or ACO Fit in 9290 07 00 150 J 150 9190 07 00 350 8 150 Installation of floor drain Floor drain 9390 07 00 350 8 150 DN 70 Variant CR 9292 07 00 150 150 gt Place drain body in existing recess For core bores observe 9192 07 00 350 8 150 the following table eer 130 9290 1
4. ection of sealing must be executed as described before Upper parts with adhering flanges compression sealing flanges are supp lied with a sealing ring which must be fitted between drain body and upper part During assembly of upper part the correct seating of the sealing ring lip pointing downwards is important refer to detail 1 The sealing ring fig 7 prevents the ingress of back flowing wastewater into the existing floor structure If seepage water shall be drained away from the lower sealing membrane the sealing ring must not be installed refer to se lection aid fig 9 10 In case of need the upper part can be cut to length O Incase of upper parts with lateral inlet the inlet pipe is shoved into the lateral sleeve Commercial plain conduit sleeve systems DN 40 are suitable for floor drain upper parts DN 70 plain conduit sleeve systems DN 50 are sui table for floor drain upper parts DN 100 Assembly of upper part intermediate section of industrial drain Contrary to the Variant CR drain a sealing ring with lips is used with the industrial drain instead of a roller ring During installation works this sealing ring has to be inserted in such a way between drain bo dy and upper part intermediate section that upper edge is placed on the drain flange fig 8 Lubricant must be applied to the sealing lips Cut top sections must be chamfered in the socket area Drain body Fig 8 Assembly of e
5. esive Compound sealing Floor drain Variant CR with compression sealing flange DN 100 with bell shape Unfinished i odour seal concrete slab Inclined screed Sealing membrane Insulation Fig 11 Especially in floors with fire resistance classes the ACO Fit in dry construction kit in connection with ACO floor drains and fire pro tection kit complies with fire protection requirements up to R 120 accessories gt For further installation notes refer to ACO Fit in installation manual il ACO Fitin dry construction kit Fig 12 Service Line Tel 49 0 36965 819 0 S Fax 49 0 36965 819 361 ACO Passavant GmbH Im Gewerbepark 11c 36457 Stadtlengsfeld Tel 49 0 36965 819 0 Fax 49 0 36965 819 361 www aco haustechnik de The ACO Group A strong family you can build on 0152 87 58 B 02 2011 edition HT 905 03 2011 e Vers 2 0 eLTC Subject no 0152 87 58 B Subject to technical alterations
6. g in surface in the drain socket must be free of grease lf the odour seal with the roller ring is not located properly risk of leakage persists which leads to water escaping and no longer pro tecting against sewer odours Bell shape odour seal Fig 2 Installation of bell shape odour seal with lip seal ACO Floor drains Variant CR DN 100 with inclination 90 Lubricant must be applied to the lip seal and the odour seal must be placed vertically into the drain socket During assembly it must be observed that sealing is properly seated fig 3 Bell shape odour seal Fig 3 Service Line Tel 49 0 36965 819 0 Fax 49 0 36965 819 361 Installation of dip pipe odour seal ACO Floor drains Variant CR DN 70 DN 100 with inclination 1 5 Insert odour seal and tilt in direction of arrow Turn catch by 90 fig 4 Dismantling in reverse order Dip pipe odour seal Drain body Fig 4 Installation of dip pipe odour seal ACO Industrial drains Variant CR DN 100 DN 150 with inclination 90 and 1 5 Pay attention to correct position of sealing Ridge must point to outlet direction Sealing offset must be positioned in the outlet notch fig 5 Bucket Sealing Dip pipe odour seal Drain body Fig 5 Insert odour seal Tighten both nuts right and left at odour seal evenly across span ner width 17 Insert bucket Dismantling in reverse order
7. ng ring fig 10 When using the sealing ring the annular gap between drain body and top section socket is closed buoyancy safe Seepage water is not drained off when using the sealing ring Potential equalisation In the case of buildings with a protective equipotential bonding via the main earthing terminal for the whole electrical plant floor drains must principally not be connected to an additional protective equipotential bonding if expertly installed in accordance with these instructions In buildings in which connection to the protective equipotential bon ding is recommended connection can be carried out at existing ear Service Line Tel 49 0 36965 819 0 Fax 49 0 36965 819 361 Fig 9 Fig 10 hing screw in the case of stainless steel drains with adhering flange This is marked with the symbol Connection of drains with compression sealing flange is possible at all screws above the loose flange In the case of drains without earthing screw connection with a suita ble earthing clamp is possible The specifications of DIN VDE 0100 701 have to be observed ACO Haustechnik 0152 87 58 B Installation examples Floor structure with sealing and thin bed process Floor structure DN 100 with compression sealing flange Kitchen side room Flexible joint Floor tiles laid in gradient NAN NAN ANA SNSNSANSANN NSN SANS ANNAN NNN NANA AANA NNN SSNS NANANNNSASY Tile adh
8. xtension In the case of high floor structures the socket of the top section must be adjusted by means of the extension art no 9392 27 31 DN 70 125 mm art no 9392 20 31 DN 100 198 mm or art no 9595 20 31 DN 100 DN150 242 mm In case of need the extension can be cut to length For assembly refer to top sections Assembly of top section gt Inthe case of floor drains which are equipped with continuous ly height adjustable top sections the retaining ring must be shoved over the cylindrical socket of the top section with the reinforcement ribs pointing downwards gt Then the top section must be inserted in the drain body in such a way that the top section with its socket extends into the drain for at least 5 mm When using the retaining ring and if top section is grouted with liquid material please make sure that no grouting component enters the drain through the retaining ring For further information refer to top section installation manual Selection aid planning installation Retaining ring with seepage water bars fig 9 When using the retaining ring with seepage water bars seepage water possibly accumulating may be drained into the drain base body above the lower sealing level e g when using the connected sealing membrane as water bearing level Possibly accumulating water in the outlet e g with pipe blockage may enter the floor structure between the seepage water bars or Seali