CA-10 with LCD-L keypad user manual

image

Contents

1. type or if it belongs to another partition Pressing the key or will end the function The control panel will automatically end the function if none of the outputs is of the MONO switch type or if no key on the keypad is depressed for 40 seconds The function is accessible to the master user as well as to the users with authority levels 1 and 5 N Control panel CA10 plus with LCD L keypad User s Guide Bi Switch function 8 The purpose of the function will be determined by the installer It can be used e g for switching on external lighting or any electrical equipment After calling the function the control panel generates two short beeps and waits for the output number key 1 6 to be pressed Provision is made for multiple control of the same output or control of different outputs of the BI switch type after single calling of the function Activation of the output is confirmed by four short and one long beeps and its deactivation with three short beeps Refusal of control is signaled with two long beeps The control panel may refuse control if the output is not of the BI switch type or if it belongs to another partition Pressing the keys or will end the function The control panel will automatically terminate the function if none of the outputs is of the BI switch type or if no key on the keypad is depressed for 40 seconds The function is accessible to the master user as well as to the user
2. display zone descriptions partition and user names Technical Reliability of the Alarm System The alarm system is built of the devices whose reliability is vital in effectiveness of offered protection The elements of the alarm system are subject to various outside influences for example weather conditions outside signaling devices lightning overhead telephone lines power lines outside signaling devices mechanical Control panel CA10 plus with LCD L keypad User s Guide 13 damage keypads detectors Only permanent control of the alarm system operation ensures keeping high level of burglary and fire protection The control panel is equipped with a number of safeguards and auto diagnostic functions testing the reliability of the system The control panel signals trouble detection by switching the TROUBLE control on the keypad on The signal should be immediately taken care of if necessary the installer should be consulted It is necessary to periodically test the reliability of the alarm system check every single detector s ability to signal zone violation by opening the protected windows doors etc It is also necessary to check signaling devices and telephone voice messaging system The installer gives specific instructions on how the system should be controlled Periodic commissioning of the installer s maintenance service is strongly recommended HISTORY OF THE MANUAL UPDATES The updates below refer to the manual for the
3. event e access to numerous USER FUNCTIONS by means of function list item selection Armed modes To adapt the alarm system to various needs the control panel CA 10 plus offers several armed modes Audible armed mode The mode in which detectors connected to the panel control the protected facility and violation of the protected zones is signaled by the panel with all available means sirens monitoring stations message transmission telephone messages Silent armed mode Armed mode in which alarms are signaled only in the panel keypads The installer can decide which of the detectors are automatically by passed in this mode he can also choose signaling device to be used in that mode Partial armed mode The installer can determine the detectors in the system which will be excluded from the surveillance on arming the system with the special access code authority level 7 It enables the user by entering an appropriate code to arm the system fully or in a chosen part only 2 Control panel CA10 plus with LCD L keypad User s Guide Stay armed mode In this mode the panel enables automatic bypassing of chosen detectors if immediately after arming the system the user did not leave the facility and did not activate the entrance exit detector Operating instructions Operating of the alarm system consists basically in arming and disarming the system setting surveillance mode and offering an appropriate reaction to the information
4. of the system Arming and disarming will occur every day at a specified time The control panel can also be armed with a timer and disarmed manually by a user Alarm System Status Telephone Messages The owner of the facility with CA 10 plus control panel installed can check if the alarm is on by means of a standard telephone connection In order to do so he has to phone the facility the control panel will answer the phone and will brief the caller on the system status The control panel will answer telephone calls only when the whole protected facility is armed On receiving the call the control panel sends e one beep a second if since the last arming time there no alarm occurred e speech synthesizer message if the alarm occurred within the last hour e sequence of five short beeps if the alarm occurred more than an hour ago The installer decides if the function is on and how the control panel answers the phone calls number of rings double calling etc Control Panel Interfacing with MST 1 Telephone Control Module The control can be effected from a telephone the control panel calls up during voice messaging immediately after the message from speech synthesizer is reproduced or after a connection is established with the panel from any telephone set Having answered the call the module connected to the CA 10 plus reports its readiness with three beeps high low and high pitched It is possible to perform operations of tw
5. OBRA Control panel CA10 plus with LCD L keypad User s Guide 3 By creating new user access code the master user assigns specific so called authority level determines which of the panel functions are available for a particular user and which are excluded Normally entering access code in one keypad will affect only in one partition It is possible to switch on installer accessible option global access codes Switching on this option causes that users access codes are accepted in all 4 partitions each user can access do any of existing partitions In this case there will be no information about user number in panel s event log Arming Access code Arming is only possible when the partition is not signaling alarm and is not already armed ALARM and ARMED diodes are off In order to arm the system access code should be entered and confirmed by pressing key If while typing the code user makes a mistake key should be pressed and the code re entered When the code is correctly entered the display shows both a message confirming entering armed mode and the name of the user who activated it Then an exit countdown message is displayed if the option was allowed by the installer The partitions in which the countdown procedure is on are visually represented by blinking ARMED diodes with appropriate partition letters Accepting the command to arm the system can also be confirmed with an appropriate sound code thr
6. Own Code function 1 The function enables changing the access code of the user who called it On calling the function a new code should be entered and confirmed by pressing key The keypad will confirm the access code change and will display the new user s name The function is available to the master user and users with authority level 1 2 or 7 Add User function 2 The function is available only to the master user The user can add new users to a specific partition assigning an access code to them and determining their authority level The master user thus determines the extent of the remaining users control over the system The function enables new access code programming determining new code s authority level and entering new user s name An access code can have the following authority levels 1 all functions available except for creating and deleting users 2 arming and disarming functions available as well as changing access code 3 arming function available as well as disarming but disarming only on condition that the system was automatically armed 4 access code trap arming and disarming functions available but after disarming the system the DURESS message is sent to the monitoring station 5 activates the output of mono type the use of the switch is determined by the installer 6 switches the output to bi type the use of the switch is determined by the installer Control panel CA10 plus with LCD L keyp
7. User Manual Alarm Control Panel CA10 plus software version 4 7 with LCD L Keypad Sarre GDANSK N WARNING In order to avoid any operational problems with the control panel it is recommended that you become familiar with this manual before you start using the equipment Telephone terminals of the panel should be connected to PSTN lines only Connecting to ISDN lines may lead to damage of the equipment In case of upgrading the PSTN line to ISDN system owner should contact the installer Making any construction changes or unauthorized repairs is prohibited This applies in particular to modification of assemblies and components Maintenance or repair operations should be performed by authorized personnel i e the installer or factory service CAUTION The alarm system is fitted with a battery After expiry of its service the battery must not be thrown away but disposed of as required by the existing regulations European Union Directives 91 157 EEC and 93 86 EEC The SATEL Company recommends that operation of the whole alarm system be regularly tested However a reliable alarm system does not prevent burglary assault or fire from happening it only diminishes the risk that such a situation will cause no alarm or notification History of the updates to this manual is attached at the end hereof Control panel CA 10 plus with an LCD keypad Alarm control panel CA10 plus is a modern microprocesso
8. ad User s Guide 7 partial arming of the system the code arms the system with simultaneous bypassing of a group of zones determined by the installer in service functions except for that the code gives the same authority as level 2 8 arming and disarming available without the possibility of changing access code 9 only arming available 0 only clearing the alarm available NOTES The access codes of type 5 and 6 may be used in the following way 1 In the user function basic mode CODE 7 or CODE 8 which allows multiple control of single outputs see description of user functions 2 In the mode realized in the previous versions of alarm control panel i e CODE which simultaneously controls all the particular types of outputs belonging to the partition to which the given access code is assigned Using the access code with authority level 5 or calling the function 7 is recorded in event log as the Entry Exit guard round To make the control possible there must be compatibility between the code type output type and partition assignment New user s access code can be edited with additional arrow keys After confirmation of the new access code and its authority level the keypad displays the current name of the user for example P 1 user 1 It can be changed by entering new name max 16 characters deletes the character before the cursor alphabet switches between insert typeover modes alpha
9. age appears when the battery voltage is too low lower than 12V under normal operational load The state may hold for several hours after current supply disconnection or after connecting alow battery The battery charging time is dependent on its capacitance the battery is charged with 350mA or 700 mA direct current the battery testing time necessary for determining its state is about 12 minutes Telephone line troubles e No voltage on the telephone line the message appears when the telephone line to which the control panel is connected is cut off It may also appear when the telephone connected to the same line is off hook for longer than the time specified by the installer service function FS117 e No dialtone or Wrong dialtone the cause of the message is telephone connection trouble no signal or busy signal while going off hook The message does not disappear till the next successful 8 Control panel CA10 plus with LCD L keypad User s Guide telephone connection It can be cleared by calling the alarm check function and pressing key OutX trouble no detectable load for example the siren wiring is cut or overloading short circuit in most cases service should be called No RS printer stands for not ready status of the printer attached to RS 232 port of the control panel as a result of for example paper load trouble or no power supply The RS 232 port is monitored if the installer sets up real tim
10. bet a ay While programming text messages the keys lt gt change the cursor position key switches the operating function mode numeric or text and key confirms the entered text The remaining keys has functions dependent on the operating mode Text mode is signaled with a sign in the upper right corner of the display Control panel CA10 plus with LCD L keypad User s Guide 11 Numeric keys in text mode insert letters at the cursor position according to the preceding table Small characters are entered by pressing a numeric key twice AY keys enable the previous next character selection In numeric mode A key deletes the character before the cursor and W key switches between insert typeover modes Erase User function 3 The function enables deleting the user selected with the cursor blinking field On pressing and holding down the A or W key the name of the user indicated with the cursor appears The cursor can be positioned with lt gt Function is available only to the master user Zone Bypassing function 4 The function enables zone bypassing in order to partially switch off the alarm system in the protected facility or skip the broken down detectors W key changes the status of the zone operational bypassed indicated by the cursor Pressing A key displays the zone name The cursor can be positioned with lt gt keys It is possible to choose a zone by giving its number with the numeric keys of the panel
11. by holding the appropriate number key down For example the keypad is attached to partition 1 it is its basic partition after holding down the key 2 for a short time it is switched to partition 2 after repeating the procedure with key 3 it is switched to partition 3 and after holding down key 1 the basic partition returns Attention The GOTO function described above is active only when the installer sets the parameter Function GOTO Calling mode according to LCD Alarm Memory Review Holding down key 5 activates the Alarm Memory Review function The message Alarm Memory Review W lt is displayed Pressing any of the arrow keys causes the date time and last alarm origin name to appear Pressing A or v keys enables scrolling the event log Pressing lt and gt keys causes the zone description to appear key cancels Alarm Memory Review function The control panel distinguishes between three types of alarms Control panel CA10 plus with LCD L keypad User s Guide 7 zone alarms break in assault fire etc alarms set up by the installer anti tampering alarm signaling attempts to dismantle or damage any part of the alarm system keypad activated alarm fire auxiliary or panic type alarms Trouble Memory Review On holding down key 6 the Trouble Memory Review M4 gt message is displayed Pressing any of the arrow keys causes the date time and last trouble type detected name to appear On pressing A key
12. control panel with program version 4 1 Date Program Description of updates version 08 2002 4 2 A new section added operation via a telephone of the control panel working with MST 1 telephone control module see p 4 NOTE Control is not made available by the panel if it calls itself reporting an alarm 01 2003 4 3 e Disarming only effected by entering CODE from keypad p 3 previously also CODE e Battery trouble added as one of conditions of preventing the system from being armed p 3 e Control panel operation made available on receiving alarm message in case of a joint work with MST 1 module p 5 e Change of the control panel reaction to entering CODE from keypad Now the panel always enters the user function mode thus enabling the functions 7 or 8 irrespective of whether it is armed or not The other user functions are only available with no alarm condition and the system disarmed p 9 e Introduction of notes regarding codes with authority level 5 and 6 p 10 e Audible distinction introduced in functions 7 and 8 for output activation deactivation p 11 e Change of description regarding performance of user functions 7 and 8 pp 11 12 07 2003 4 7 e A note on functioning of the trouble indicator has been added key 7 function p 7 e Anew type of trouble added No battery p 7 e New option that applies to possibility of activation the functions assigned to ar
13. e event printout RAM error the message appears on erratic microchip operation of the system it may be caused by strong electromagnetic interference produced by lightning in most cases service should be called Keypad power supply trouble signals an installation error servicing is necessary the message can be displayed only while reviewing alarm memory Switching the Chime on off The function enables switching the chime on off acoustic signaling of the violation of specified detectors by means of the keypad The switching off of the function with the keypad is confirmed with three short beeps switching on with one longer and four short beeps The installer decides which zone and which keypads can use chime to signal their status Fire Alarm The function enables switching on off of fire alarm by means of the keypad Auxiliary The purpose of the alarm depends on the current needs It may for instance be an emergency call for doctor s help The function may transmit an appropriate message to monitoring station and activate voice messaging Panic alarm The function enables activating the panic alarm by means of the keypad CHANGING DISPLAY MODE OF SYSTEM STATE This function makes it possible to change the LCD display operating mode from displaying text messages about the system state into displaying the state of armed zones or the other way round The keypad will automatically return to the installer s
14. ee short beeps if the option of key sound confirmation was turned on by the installer The panel may fail to arm the system if e in the panel there are specifically designed zones which cannot be violated while the system is being armed and one of them is being violated at the time the panel signals the situation with three long beeps In such a case a delay is recommended until all the exits are ready and arming the system again Pressing the lt button displays the exits being violated If one of the exits remains violated the cause being for example the detector trouble the armed mode can be switched on after the exit has been blocked function 4 e access code entered is incorrect the control panel signalizes the event with two long beeps e in the partition there are no armed type zones the control panel signalizes the event with two long beeps access code is correct and allows for example to call user functions e battery trouble three long beeps proper option is selected to prevent the system from being armed in case of battery trouble Quick Arming O On pressing the sequence 0 user can without typing access code arm the system The Quick Arming function can be blocked by the installer Arming is not influenced by any detectors being violated at the time The installer can assign a special key to arm the system quickly Disarming and clearing the alarm Access code When the control panel is ar
15. et operating mode after approx 40 sec User function menu If the control panel is not armed and is not signaling any alarm after entering the access code and pressing key the panel switches to user function selection mode The beginning of the list of user functions appears on the keypad The set of user functions currently available depends on the authority level of the access code with which the user functions menu was activated Control panel CA10 plus with LCD L keypad User s Guide 9 list of functions Change own code Add user Erase user Bypass zones Arming silent Set time Mono outs activ Bi outs switch Supply reset Tel DWNL start Events review the arrow points to the function that will be activated by pressing or gt key gt Change own code Add user SCOMNDARWYo The A and W keys enable scrolling through the user functions and gt keys activate the given function It is possible to activate a function directly when User Functions Menu appears on the display by means of pressing an appropriate numeric key similarly to calling a function by means of LED keypad Choosing User Functions with the Menu is very simple as the display shows clear function descriptions NOTES The functions 2 and 3 are only available to the partition master code user The functions 7 and 8 are always available irrespective of whether the control panel is armed or not Change
16. for example 3 will enable bypassing of zone 13 The function is available only to the master user with authority level 1 Silent Armed Mode function 5 In silent armed mode the alarms are signaled only in keypads and by sending an appropriate message to monitoring station The installer decides if silent armed mode is valid in all the protected facility or if in a selected area it will be disarmed The function is not available for user with authority level 5 6 0 Setting Time function 6 The programmable parameters time data year can be edited with additional keys lt and keys position the cursor A key deletes the character before the cursor W key switches data entry mode insert typeover The function is available only for the master user and a user with authority level 1 Mono Switch function 7 The purpose of the function will be determined by the installer It can activate e g electric locks bells signal lamps or any other devices After calling the function the control panel generates two short beeps and waits for the output number key 1 6 to be pressed Provision is made for multiple control of the same output or control of different outputs of the MONO switch type after single calling of the function Correct performance of the control is confirmed by four short and one long beeps and refusal of the control by two long beeps The control panel may refuse control if the output is not of the MONO switch
17. ling the function shows by means of ARMED diode s the partition s where alarm was activated and on the LCD display the names of partitions every time the A key is pressed next partition name is shown Find the violated zones lt key The function displays the names of violated zones The zones are shown on pressing the lt key the function shows the partition zones as selected in Zone Setup by the installer Find the zones that caused the alarm gt key The function displays the zone names for which the alarm has not yet been cleared individual alarm memory for zones Every time the key is pressed next zone name is shown Find the partition where the keypad is attached Vv key The function displays the name of the basic partition operated with a keypad the partition to which the keypad is physically attached User HOLD DOWN Functions The functions are available to every user without entering any access code They are activated by holding the function key down for a short time Switching to n partition GO TO n DOO In alarm systems divided into several partitions Subsystems single keypad control over the whole system is possible The keys 1 2 3 4 kept down for a short time switch the partition the keypad is currently controlling The keypad remains in the chosen partition for some time and then returns to its basic partition It is possible to switch between the partitions and return to the basic partition
18. med ARMED diode is on or signalizes the alarm ALARM diode is blinking it can accept only one order disarming the system or Control panel CA10 plus with LCD L keypad User s Guide clearing the alarm Typing the access code confirmed by pressing keys disarms the system or turns off the alarm If while typing the access code user makes a mistake she he should press button and re enter the code The control panel will not be disarmed or allow the alarm clearing if e the access code is incorrect e or the access code authority level does not allow disarming for example authority level 3 or 9 see User Functions Menu New User It is possible to cancel the alarm without disarming the system with authority level 0 access code Disarming the system is confirmed with an appropriate message on the LCD display and the name of the user who armed the system If the alarm has been cleared the keypad will display the message Review AV gt the arrow buttons allow reviewing partition status to find out the source of alarm In the alarm system divided into zones it is only possible to cancel the alarm in the zone whose keypad is signaling alarm with its alarm LED By pressing the A key you can check in which zones the alarm was triggered Timer Controlled Arming and Disarming Arming and disarming of the system can be controlled with a control panel timer The installer can program the exact hour and minute of arming disarming
19. o types 1 Checking the status of zones or partitions 2 Performing a user function Control panel CA10 plus with LCD L keypad User s Guide 5 The below table presents the functions performed by the MST 1 module hecking the status of partition 2 hecking the status of partition 3 hecking zones status Zones bypass Controlling of the output of BI switch type The control is performed using DTMF signals of the telephone keyboard To call the selected function press sequentially telephone keys in accordance with the calling method as shown in the table Partition status signalling e three short beeps partition disarmed e four short and one long beeps partition armed Alarm in a partition or memory of an alarm are signalled with a series of short beeps changing from high to low that last approx 2 5 seconds directly after signals informing on partition status The function Checking zone status can readout the information which of keypad s LEDs shine with a steady light and which of them are blinking During co operation with CA 10 plus control panel the module informs in accordance with the settings of service functions FS 12 do FS 15 The indication of a zone of an armed partition means memory of an alarm triggered by this zone while the indication of a zone of a disarmed partition means violation of the zone In the CA 10 plus control panel the installer himself defines the numbers of zones to be indica
20. r based device designed for signaling burglaries and assaults The CA 10 plus panel controls the operation of an alarm system responds to information coming from the alarm system detectors about an intrusion on a protected facility and informs about the event The panel is designed to be operated with LCD display keypads and LED keypads Basic functions of CA 10 plus e signaling burglary panic and fire alarms e informing of alarms with telephone voice messages or messages to a paging system e answering phone calls and informing the user of system status whether an alarm occurred since its arming e monitoring communication with telephone monitoring stations real time transmission of detailed information about specified events in a protected facility e real time printout of reports on all events in the system on an external printer Features of CA 10 plus e panel operation controlled with LCD text display keypads 2x16 characters e clear text messages describing system status and important events e installer defined zone descriptions simplifying identifying the alarm origin e simultaneous detailed status presentation of up to 16 zones controlled by the panel e visible clock and system date display helpful in supervising and ensuring error free operation e reviewing the alarm and trouble logs or detailed memory log of all system events with text description zone name partition name or user name and exact time of the
21. row keys has been added p 6 LCD DISPLAY time and date or partition ALARM alarm in the current TROUBLE signals trouble name and system status message partition detection in the system to check press key for 3 seconds DDA pressing any of the ARMED A B C D where ABC D keys for 3 seconds switches to ALARM CONTROL PANEL CA 10 LCD Satel stands for partition available in one of the four partitions the system 1 A 2 B 3 C 4 D io what Goer 6 4 control on the partition is armed control blinking counting down exit pressing the key for 3 delay time seconds activates Alarm Memory Log Review j trouble pressing the key for 3 seconds activates Trouble Memory Log lt identifying violated zones Review i A identifying the partition gt identifying zones where signaling alarm alarm occurred Y displaying partition name pressing the key for 3 seconds switches between text and zone state displaying pressing the key for 3 seconds displays the trouble currently detected pressing the key for 3 seconds pressing the key for 3 seconds activates Panic Alarm activates Fire Alarm pressing the key for 3 pressing the key for 3 CODE arming disarming ACCESS CODE user menu seconds activates Auxiliary seconds switches the chime functions Alarm on off
22. s with authority levels 1 and 6 Power Supply Reset function 9 The function is used with special detectors equipped with individual on off memory which is cleared by shutting down power supply for example smoke detectors broken glass detectors The function temporarily disconnects power on the power outputs with RESET function The function is available for the master user and a user with authority level 1 Start Download function 0 The function can be activated by the master user and a user with authority level 1 It starts the control panel servicing PC remote telephone connection The function enables the panel PC telephone connection when an attempt at establishing connection from the outside computer is blocked When the panel is in DOWNLOAD mode the telephone line is busy only while data is being transmitted During programming sessions the PC can send a request to stop the current connection and wait for the next one Such an attempt at re establishing connection will be accepted by the panel regardless of the outside connections being blocked Closing the programming session will be successful after the PC sends the CLOSE message or after four hours since the last connection elapse Reviewing Events Memory Log additional function On activating the function users can review the memory log in which all the events are recorded in detail AW keys enable scrolling the list of events lt gt keys enable additional data
23. ted by LEDs of the keypad assigned to the partition such keypad needs to be connected to the control panel It is possible to check the status of LEDs numbered from 1 to 12 The method of checking the zone status e After the first calling of the function 9 the module generates short beeps the number of which is equal to the lowest number of a shining LED If none of LEDs shines the module generates two long beeps e The subsequent calling of the function 9 indicates the next LED which is shining The review needs to be continued till hearing two long signals informing that there are no more LEDs shining The repeated calling the function after two long signals will restart the review of zone status e In order to check the zones status in the control panel CA 10 plus first it is necessary to check the status of one of zones through calling an appropriate function 1 2 8 or 4 and afterwards to check the status of its zones with the function 9 Each of zones needs to be called separately C C Checking the status of partition 4 C A 6 Control panel CA10 plus with LCD L keypad User s Guide lt A Y P Key Functions Activated by installer functions assigned to 4 a V gt keys help in everyday control of the system operation Find the partition where alarm was activated A key In multi partition systems the find function enables determining the partition where alarm was activated On cal
24. the control panel signals on the keypad The keypad displays the information about the status of the alarm system by means of a two line backlit LCD display 2x16 characters and six additional LED controls LED functions e ALARM diode on signals alarm mamconmaor eanet caro co Satel e TROUBLE the LED is blinking when the control Io Repr 13 265 Ad panel detects a technical System OK problem or a telephone messaging trouble Pe e ARMED ABCD partition status signaling blinking while the alarm control is off signals exit delay running control stays on when the partition is armed The LEDs marked with letters AB C D correspond to numerical denotation of Figure 1 View of LCD L keypad partitions available in the system LED A partition 1 LED B partition 2 LED C partition 3 LED D partition 4 User access codes For everyday operation of the system assigning user access code is essential The control panel comes with one factory set code master user code for each partition 1234 for partition A 2345 for partition B 3456 for partition C 4567 for partition D Programming of additional 12 user access codes is possible in each partition but no more than 32 in the entire system The code can be 4 to 6 digits long The number key letters help the user memorize a code by associating it with a particular word e g the 5 6 2 7 2 code corresponds to the word K
25. the list of previously detected troubles is displayed on pressing W key the list of subsequent troubles key cancels the function Current Trouble Check out When the control panel indicates a trouble detection TROUBLE diode is blinking holding down key 7 activates the Current Trouble Check out function On the keypad display a trouble message appears If there are more than one trouble pressing of 4A or WP allows scrolling through all the troubles detected NOTE If the installer has activated the Indicate trouble until cancelled option the trouble indicator will be on until cancelled even if the trouble cause has been removed The trouble will be cleared after completing the trouble memory review and quitting the function by pressing the key Quitting the function by means of another key will not cancel blinking of the TROUBLE diode The control panel detects the following problems No 230V power supply the control panel is equipped with back up power supply that enables it to function for a specified period of time If however the non 230V power supply message appears in spite of the fully operational wiring service should be informed Clock loss the message appears on disconnecting and reconnecting the control panel the clock can be set with user function 6 No battery the battery is not connected or almost discharged or the fuse on the control panel board is out of order Low battery the mess