Home

TekTerm Server Software User Manual

image

Contents

1. 1 3 Write Error Code 3 4 WAZEBRA TECHNOLOGIES Zebra and the Zebra head graphic are registered trademarks of ZIH Corp The Symbol logo is a registered trademark of Symbol Technologies Inc a Zebra Technologies company O 2015 Symbol Technologies Inc All other trademarks are the property of their respective owners 8000281 001 Revision A April 2015 tee
2. 2 13 3 13 Backup IP Address 16 4 Barcode 2 10 3 10 7 9 base station 12 3 connectivity options 12 4 TCP IP options 12 4 BaudRate 13 7 Beacon Gateway Interface 15 4 Beacon Period 15 3 Beacon UDP port 15 4 browserinterface 1 3 local connection 1 3 remote connection 1 3 C Callsign Period 13 4 Callsign Ging 13 4 Callsign Text 13 4 cellular switching 14 3 Ee I E EREA A EE E ooo 2 5 3 5 7 4 Close Host sessions on Terminalreset 4 8 Collision Size 13 4 Combination 1 13 7 Combination 2 13 7 Command Region 2 11 3 11 7 10 Communication Protocol 13 3 configuration SV re ee 18 3 ET 18 3 connectivity options base station 12 4 conventions tekt xii Convert 7 to8Bits 4 7 5 6 Custom Device Namses 3 15
3. Command Region These two pairs of text boxes define a region of the host screen which the TekTerm Server examines for the presence of reserved commands The first text box of each pair contains the row number the second contains the column number These four numbers represent the row and column addresses of the upper left corner and the lower right corner of the command region To define the last two lines of the host screen as the command region enter 23 1 24 80 The only commands supported in the command region are ALARM and FONT e When the word ALARM is placed anywhere within the command region the TekTerm Server sends a TESS beep command to the mobile device e When the word FONT is placed anywhere within the command region and followed by a number the font code the TekTerm Server sends the appropriate TESS Change Font command to the mobile device For font codes see Font Code List for Open TekTerm on IngenuityWorking Font codes are only required for versions of OTT before version D Rows 0 to 24 Columns 0 to 80 Default 0 0 0 0 3 12 TekTerm Server Software User Manual AIAG Mode Values The mode character is derived by starting with the decimal value 43 ASCII character 0 zero and adding the appropriate value from the table below Code Description 1 Prevent the AlAG prefix from being displayed 2 Prevent the AIAG prefix from being sent to the host 4 Cause a transmission to the host when all AIAG fie
4. Polling by the Secondary TekTerm Server The secondary TekTerm Server polls the primary TekTerm Server at intervals specified by Poll Interval s After each poll this TekTerm Server waits for a reply It waits for a time specified by Poll Timeout s If there is no reply during this interval the TekTerm Server sends another poll to the other TekTerm Server The total number of polls sent while this TekTerm Server waits for the other TekTerm Server to respond is spec ified by Poll Tries If no response is received to any of the polls this TekTerm Server then pings the arbiter If the TekTerm Server receives a reply to the ping from the arbiter but cannot contact the other TekTerm Server it assumes that the other TekTerm Server is off the network becomes the primary and takes control of the Psion system If this TekTerm Server cannot reach the other TekTerm Server or the arbiter it assumes that the network is not working and remains in secondary mode 16 4 TekTerm Server Software User Manual Redundancy Parameters Screen General Redundancy Options Field Description Enabled When selected the TekTerm Server uses the redundancy feature A second TekTerm Server appropriately configured and an arbiter must be present on the network for the feature to operate properly Default Not selected Preferred Primary When selected this TekTerm Server is the preferred primary TekTerm Server There can only be one preferred primary
5. When auto Telnet and auto login are enabled the TekTerm Server initiates one Telnet session from each mobile device whose terminal number is mapped to this host It then logs each session in to the host using the username and password provided in this screen The username and password is identical for all auto Telnet sessions automatically logged in to this host Values DISABLE AUTO TELNET AUTO TELNET LOGIN Default DISABLE Auto telnet Host The name or the IP address of the host to which auto Telnet requests are directed Any host name which can be used at the TCP gt prompt on the mobile device may be used here Default None Note The host name must be resolvable by the TekTerm Server The TekTerm Server must be able to obtain an IP address for it For example the host name may correspond to an entry in the TekTerm Server host table or the TekTerm Server may be able to query a domain name server 4 10 TekTerm Server Software User Manual Auto telnet Terminal The text presented to the user to request a login Prompt Non printable characters such as are used in escape sequences are allowed These characters can be entered using either octal or hexadecimal digits An octal escape sequence takes one of the forms Od or Odd or Oddd where each d can be any digit 0 to 7 A hexadecimal escape sequence takes one of the forms xh or xhh where each h can be 0 to 9 or any of a to f or A to F Each of these numeric esc
6. Default Selected 3274 Telnet Terminal Naming Screen This screen opens when Configure LU names is clicked on the 3274 Telnet Protocol Options Screen Field Description Terminal number The number of the terminal which has the name in Terminal name Values 1 to lt number of configured terminals gt Default 1 Terminal name An LU name for the terminal This name can contain no more than 10 alphanumeric characters If no terminal name is specified here for a terminal the TekTerm Server appends the terminal number as five digits with leading zeros if necessary to the LU Prefix to create the full LU terminal name Values 1 to 10 characters Default None 2 16 TekTerm Server Software User Manual Buttons Show Set Displays the LU name associated with the terminal number If you have just entered a terminal number and LU name press this button to add the terminal number and LU name to the list of configured terminals Delete Deletes the currently displayed terminal number and LU name from the list OK Saves changes to the database When it is pressed the TekTerm Server displays a confirmation screen Press OK in this screen to save the changes and exit to the 3274 Telnet Protocol Options Screen Validate Validates with the option to save the changes to the TekTerm Server database On the Validation Results screen after reviewing any error messages you can click one of the following Cancel Returns to the 32
7. Default Selected Poll Interval s The poll interval when this TekTerm Server is the secondary Communications Server Values 1 to 10000 Default 10 Poll Timeout s The poll timeout when this TekTerm Server is the secondary Communications Server Values 1 to 10000 Default 2 Poll Tries The number of poll retries when this TekTerm Server is the secondary TekTerm Server Values 2 to 99 Default 3 Available Interfaces At the top of this section of the screen is a list of network adapters detected by the TekTerm Server software Field Description Backup IP Address The address of the other TekTerm Server Values Any valid IP address Default 76 128 0 2 Alias Network Mask The network mask for the alias IP address of the primary and secondary TekTerm Servers This network mask must be the same on both TekTerm Servers Values Any valid IP network mask Default 255 255 0 0 Field Description Redundancy Configuration 16 5 Alias Interface The interface number through which this TekTerm Server communicates with the other TekTerm Server Values Selected from the list of network adapters detected by the Communications Server Default 0 Ethernet Alias IP Address The alias IP address for this TekTerm Server and the other TekTerm Server in the redundancy system This address must be the same on both the primary and secondary TekTerm Servers Devices on the network may have more than one IP address corr
8. Maximum number of hosts 16 Accessing the TekTerm Server Browser Interface 1 3 Accessing Windows Desktop 1 3 Stopping the TekTerm Server 2 0 00 eee ee 1 3 Restarting the TekTermServer 1 3 ReadingeEventLogEntres 1 3 AccessingtheDebugConsole 1 4 Administering the TekTerm Server 1 3 Accessing the TekTerm Server Browser Interface TekTerm Server is configured through a browser interface Connecting locally Use the following http localhost 8008 Connecting remotely Use the following http lt IP address gt 8008 Where lt IP address gt is the IP address of the computer running the TekTerm Server Accessing Windows Desktop TekTerm Server runs as a service under Windows TekTerm Server automatically starts running when the computer starts or restarts Connecting remotely If Remote Desktop access is enabled on the computer whereTekTerm Server is installed you can connect to it remotely Stopping the TekTerm Server To stop TekTerm Server do the following 1 In Control Panel select Services from the Administrative Tools menu 2 Select TekTerm Server Watchdog 3 Select Stop Restarting the TekTerm Server To restart the TekTerm Server without restarting the hardware do the following 1 In Control Panel select Servi
9. Radio Link Features Configuration 14 3 Cellular Switching and Timeplexing In Psion proprietary systems there are two methods of operating on a narrow band radio link The first method is cellular switching Here each base station uses a different radio channel The devices monitor the radio link and automatically switch to the channel with best radio reception This cellular switching capability is trans parent to both the host and the device The second method is timeplexing Here a group of base stations at a site use the same radio channel The TekTerm Server controls the polling sequence so that the base stations do not transmit simultaneously This timeplexing capability is also transparent to both the host and the device Cellular switching and timeplexing can be combined within one Psion system A site may operate on two or more channels with several timeplexed base stations using each channel and cellular switching between the channels In all of these cases the device may move freely throughout the site without loss of communication The Psion system handles channel switching and the handover between base stations Radio Link Features Screen General Options Field Description Operate in Cellular When selected the base stations connected to this TekTerm Server operate in Mode cellular mode enabling devices to move between base stations switching channels if necessary Default Selected Poll ID The poll ID is a
10. 1000 byte s Default Disabled 17 4 TekTerm Server Software User Manual Miscellaneous Options Screen This screen contains settings for the TekTerm Server serial number and the maximum number of terminals allowed to connect to it Field Description Serial Number The serial number for this TekTerm Server Default 0 Enable Telnet User When selected the TekTerm Server reguests a username and password from Telnet Authentication sessions connecting to the TekTerm Server debug console The user names and passwords are those specified in Name and Password in Section User Screen Default Disabled Display Entire Database Contents Database Validation Results Screen 18 3 Export Import Configuration Configuration Database Import Export Menu 18 3 RestarttTekTermServer 18 3 Validate and Save Current Configuration 18 3 Miscellaneous Commands Configuration 18 3 Display Entire Database Contents Database Validation Results Screen Click Show All to display the contents of the TekTerm Server configuration database This is the permanent database from which the TekTerm Server is booted Changes made to the configuration database are stored in a configuration cache which must be saved before the TekTerm Server can use the changes Export Import Configuration Configuration Database Import Export Menu Export Database to a File C
11. D database display contents 18 3 EEN 18 3 Import 18 3 validation results 18 3 database validation results screen 18 3 datastreams xiii ANS ia cd xiii HP 2392 to HTML xiii HP 2392 to TESS xiii HTML to TESS IIIA xiii IBM 3274 to HTML xiii IBM 3274 to TESS xiii IBM 5250 to HTML xiii IBM 5250 to TESS xiii TESS See See xiii debug console 1 4 local connection 1 4 remote connection 1 4 USING EEN 1 4 Device Name Prefik 3 15 Direct TCP Check Duplicate Terminal Number 14 4 Direct TCP Connections for TekTerm 14 4 display database 18 3 Display Emulation Support Code page Character Set Keyboard Type 3 16 Display Timeout 7 4 E ECHO EE 4 5 5 5 emulation LIO EE xii O S xii A E EEA xii JOTO iii as xii ANSI ini ee ao le xii e ON xii remote sockets xii RFmodem xii TESS EE xii emulation options 76 AA ee 7 4 EE 2 4 A SA IN
12. Match a number amp Match a letter either case A Match an upper case letter _ Match a lower case letter Match an alphanumeric character KR Match a letter number or space Match a punctuation character Match any character Match all character positions in the field with the preceding character E Match any remaining characters but not necessarily the remainder of the field with the preceding character 17 12 TekTerm Server Software User Manual 2392 Telnet Protocol Options Screen Field Description Host Port The port number on the host for this connection Values 1 to 32767 Default 23 Maximum Sessions The maximum number of Telnet connections that can originate from per Terminal each mobile device Values 1 to 127 Default 4 First Local Terminal The port number from which the TekTerm Server makes a Telnet connection for Port the first terminal Additional Telnet sessions are assigned higher port numbers Values 1 to 32767 Default 10000 Local IP Address to The IP address of the TekTerm Server interface that connects to this host It is Bind used with the local port numbers to create a unique socket for each mobile device session Default 0 0 0 0 First Terminal Listen The lowest port number on which the TekTerm Server listens for Telnet Port connections initiated by the host When set to 0 zero this option is disabled Values 0 to 32767 Default 0 Auto telnet login When enabled the host connect
13. Procedures Legacy setting The last device to support this is the 7030 When selected the TekTerm Server can send TESS procedures to the mobile devices A TESS procedure is a group of TESS commands that can be executed by the TESS execute procedure command Default Not selected Local Legacy setting The last device to support this is the 7030 When selected the TekTerm Server can provide pages to be loaded as local TESS procedures in the mobile devices The local procedures are selected from a menu on the mobile device The mobile device can perform these procedures when it is offline Later when the mobile device is online it sends the results of these functions to the host Procedures must also be selected Default Not selected Field Description 2392 Telnet Host Configuration 7 5 Passthru When selected the TekTerm Server allows the host to send data directly to the serial port of the mobile device This is commonly used for printing Preparing Host Screens for Pass Through On the screen to be sent through the mobile device serial port the word PASSTHRU has to appear on the first line starting in the second column The actual data to be sent to the mobile device may start anywhere below the first line Attributes occupy a position in the screen buffer An attribute placed between column 2 and the end of the word PASSTHRU pushes all following characters one position to the right Therefore any required attributes shou
14. 18 lineDescripton 3 18 Controller Description 3 19 UC o casara dias iD 3 19 5250 Telnet Host Configuration 3 3 Overview The TekTerm Server can emulate multiple TN5250 sessions The emulation software inside the TekTerm Server converts the IBM 5294 data transparently to and from TESS or HTTP data which is then sent to and from the Psion devices The connection between the TekTerm Server and its base stations access points and devices is transparent to the IBM host Data compression And Caching Software Emulation Host Application Software Base Terminal Station or Communications Server Access Point Host Computer General Host Options Screen Field Description Name The unique name of the host Default Unnamed Host Enabled When selected the host task is started when the TekTerm Server starts Emulation and protocol Emulation and protocol combination for this host Select 5250 Telnet 3 4 TekTerm Server Software User Manual Field Description Terminal range Terminal number range that communicates with this host Range 1 to 3840 For S900L range is 1 to 50 Default 1 to 32 For information on selecting the terminal range see Chapter 19 Setting Terminal Numbers on the General Host Options Screen Auto terminal number When selected TekTerm Server assigns terminal numbers to all mobile devices assignment not that use this se
15. 2392 Telnet Host Configuration describes the 2392 Telnet specific settings Chapter 8 RF Modem Telnet Host Configuration describes the RF Modem Telnet specific settings Chapter 9 HTML Host Configuration describes the HTML specific settings Chapter 10 Narrowband Data Proxy NDP describes the NDP specific settings Chapter 11 Remote Socket Emulation Host Configuration describes the remote sockets specific settings Chapter 12 Base Station Configuration describes the narrow band base station specific settings Chapter 13 RRM Groups Configuration describes the RRM groups specific settings Chapter 14 Radio Link Features Configuration describes the radio link specific settings Chapter 15 802 10 v1 and v2 Features Configuration describes the 802 1Q specific settings xii TekTerm Server Software User Manual Chapter 16 Redundancy Configuration describes how to configure Communications server redundancy settings Chapter 17 System Configuration describes the user SNMP serial number and authentication settings Chapter 18 Miscellaneous Commands Configuration describes the commands that import export and validate the database as well as the restart command Chapter 19 Setting Terminal Numbers on the General Host Options Screen explains how the Terminal Range parameter on the Host General Options screen is calculated Supported Emulations and Protocols Use this Emulation for these Emulation Terminals Telne
16. 4 Two Hosts with No Overlapping Terminal Numbers 19 4 Two Hosts with Overlap in Terminal Numbers 19 5 Setting Terminal Numbers on the General Host Options Screen 19 3 Introduction The terminal range settings on the Host General Options screens define the terminals which are associated with each host session The Host General Options screen maps sessions on the host to terminal numbers on the TekTerm Server A range of n terminals in the Host General Options matches the lower number in the range to the first session defined on this host and the higher number in the range to the nth session defined on this host When the Terminal Range starts at 1 the host session number is identical to the TekTerm Server terminal number the offset is zero When the Terminal Range starts with a number other than 1 an offset is created equal to the lower number minus 1 For instance the range 10 to 20 implies an offset of 9 This means that the first session on the host is TekTerm Server terminal 10 The numbering scheme described in this section works for all host types however some host applications ignore the mapping Telnet connections may or may not have sessions directly associated with client terminal IDs There are some cases where 5250 or 3274 host sessions are directly related to a terminal ID such as when device naming is used The examples in this section demonstrate the effect of
17. Background Colour This is the background colour the colour of the HTML page that the TekTerm Server HTTP server sends to mobile devices connecting via HTTP The choices are the 16 predefined HTML colour names Values Aqua Black Blue Fuchsia Gray Green Lime Maroon Navy Olive Purple Red Silver Teal White Yellow Default Silver User Data Font Size This is the value for the HTML font size attribute that is applied to user data on the browser screen Values 1 2 3 4 5 6 7 Default 3 Function Key Font Size This is the size of the font that is used on the function key buttons on the browser screen Values 4pt 6pt 8pt 10pt 12pt 14pt Default 8pt Enable TekTerm When selected the TekTerm Server uses TekTerm Screen Formatter TekTerm Screen Formatter Screen Formatter was previously called TSF O Default Selected 3 14 TekTerm Server Software User Manual 5250 Telnet Protocol Options Screen Field Description Terminal Type The type of terminal to be emulated by the TekTerm Server Values IBM 5252 11 IBM 5555 B01 3179 2 Default IBM 5252 11 Host Port The port number on the host for this connection Values 1 to 32767 Default 23 Maximum Sessions The maximum number of Telnet connections that can originate from per Terminal each mobile device Values 1 to 127 Default 4 If Enable Telnet Enhancements previously called Enable Virtual Device Names is not selected all the sessions use device
18. Character Set This is the character set to be used for the first 128 character codes decimal 0 to GL 127 hex 00 to 7F This should be set to the same character set as selected in the mobile devices This parameter is only used when page saving is enabled Available character sets are ASCII DEC_Multi DEC_Graphical British_DEC Danish_DEC Dutch_DEC Finnish DEC French DEC French CDN DEC German DEC Italian DEC Portuagal DEC Spanish DEC Swedish DEC Swiss DEC Arabic Thai and a Not Listed selection Default ASCII Upper Character Set This is the character set to be used for the second 128 character codes decimal GR 128 to 255 hex 80 to FF This should be set to the same character set as selected in the mobile devices This parameter is only used when page saving is enabled Available character sets are ASCII DEC Multi DEC_Graphical British DEC Danish DEC Dutch DEC Finnish DEC French DEC French CDN DEC German DEC Italian DEC Portuagal DEC Spanish DEC Swedish DEC Swiss DEC Arabic Thai Latin Latin 2 Latin 3 Latin 4 Latin 5 Latin 6 Cyrillic ISO Arabic ISO Greek ISO Hebrew ISO and Thai ISO Default DEC_Multi Terminal Initialization As soon as communication is established between a mobile device and the Data TekTerm Server this string is sent to the mobile device Default None Host Initialization Data As soon as communication is established between the host and the TekTerm Server thi
19. Field Description Transmit Line When enabled all modified data on the mobile device is automatically transmitted when the operator enters data into an entry field on or above this line The value in this text box specifies the line on the screen which is designated as the transmit line The last entry field on or above the transmit line on the screen is identified as the field which will cause all modified data to be sent to the host Any entry fields that exist on lines below the transmit line will not cause the screen to be transmitted A value of 0 zero disables this feature A value of 24 causes the last entry field on each application screen to be defined as transmit upon entry Values 0 to 24 Default 0 AIAG The decimal value of the special character ASCII used to tag a field to use AIAG mode When barcode data is entered on a mobile device the mobile device searches for AIAG fields on the current page These fields can accept the special barcode data The data preloaded into the AIAG field by the application program determines whether a barcode is accepted The format of the preloaded data is lt mode gt lt AlAG prefix gt The application program distinguishes an entry field as AIAG by preceding the entry field with this special AIAG character A value of 0 zero disables this feature Values 0 to 255 Default 0 For the AIAG mode character table see AIAG Mode Values on page 2 12 3274 Telnet Host Configur
20. Host Prompt 3 When this string is received from the host the string in Auto Response 3 is sent to the host Default None Auto Response 3 See Host Prompt 3 Default None 5 12 TekTerm Server Software User Manual Advanced SSH options Allow SSH version 1 When enabled the SSH1 protocol is used When not enabled the SSH2 protocol is used Default Not selected Cipher List The cipher is negotiated by the host and the TekTerm Server It is chosen from among the ciphers listed in this field Applies to SSH2 only Default aes256 ctr aes192 ctr aes128 ctr aes256 cbc aes192 cbc aes128 cbc blowfish cbc 3des cbc Compression When selected if the host supports compression then the level of compression is negotiated by the host and the TekTerm Server Applies to SSH2 only Default Not selected ANSI Function Key and Arrow Key Mappings Options Screen Function Keys Each of the function key text boxes contains a code that is sent to the host when the corresponding function key is pressed on the mobile device Each code sequence is terminated by a NULL NULLs are not transmitted by the TekTerm Server Arrow Keys Each of the arrow key text boxes contains a code that is sent to the host when the corresponding arrow key is pressed on the mobile device Arrow key remapping also exists on the mobile devices but is applicable only to Telnet and SSH direct connections Function key remapping and arrow key remappi
21. Options Screen Field Description Name The unique name of the host Default Unnamed Host Enabled When selected the host task is started when the TekTerm Server starts Emulation and Emulation and protocol combination for this host protocol Select 3274 Telnet 2 4 TekTerm Server Software User Manual Field Description Terminal range Terminal number range that communicates with this host Range 1 to 3840 For S900L range is 1 to 50 Default 1 to 32 For information on selecting the terminal range see Chapter 19 Setting Terminal Numbers on the General Host Options Screen Auto terminal When selected TekTerm Server assigns terminal numbers to all mobile devices that number assignment use this session not supported by E 8 Direct TCP When not selected terminal numbers must be assigned on the mobile devices Default Selected 3274 Emulation Options Screen 3274 Options Field Description Is Host Fujitsu When selected the TekTerm Server sends data in Fujitsu format The standard IBM formatting codes for start of field setting buffers etc are replaced by the codes used by Fujitsu host computers Default Not selected Use International When selected the TekTerm Server uses the international EBCDIC character set EBCDIC the positions of the and characters are swapped Default Not selected Allow null character When selected empty fields show video attributes properly when using in fixed fie
22. Terminal number 2 15 3 17 terminal number 19 3 Terminal Offline Timeout 15 3 Terminal Protocol 2 4 3 4 Terminal Radios 13 7 terminalrange 19 3 multiple hosts 19 4 MENOS iii AE NEW 19 3 without overlapping numbers 19 4 with overlapping numbers 19 5 Terminal Type 2 13 3 14 4 8 A clad ds ae ce idee os xiii 7 4 emulation xii OPUONS eer e AE chs 2 5 3 5 9 5 text conventions xii Threshold 00 0 0 ccc cee eee tenes 4 5 5 5 timeplerking 14 3 Transmit Line 2 8 3 8 7 7 9 6 Treat EraseWrite NOP as Write NOP 2 4 USE ia 2 6 2 13 3 6 3 13 7 5 9 5 U Upper Character Set GR 4 7 5 7 Use International EBCDIC 3 4 User Data Font Size 2 13 3 13 username and passSWOrd 17 3 V validate configuration 18 3 Visible Match Character 2 9 3 9 7 8 WwW KE UE 13 7 windows desktop 1 3 remote connection
23. Undo Discards all database changes since the last database commit and returns to the Configuration Main Menu screen Displays the list of currently configured terminal names Function Key Mappings Options Screen Use the function key list boxes to select a code that is sent to the host when the corresponding function key is pressed on the mobile device Typical Host Configuration Line Description Parameter Line description Option Category of line Resource name Online at IPL Vary on wait Network controller Local adapter address Exchange identifier Ethernet standard Maximum controllers Error threshold level Text Option Category of line LIND RSRCNAME ONLINE VRYWAIT ADPTADR EXCHID MAXCTL ENETLINE BASIC ELAN LINO21 YES NOWAIT RFCTRLENET 08005AB7C3FD 05629A5A ALL 40 OFF APPN ELAN 5250 Telnet Host Configuration 3 19 Parameter Link speed 10M Cost connect time 0 Cost byte 0 Security for line NONSECURE Propagation delay LAN User defined 1 128 User defined 2 128 Autocreate controller NO Source Service Access Points SSAP Maximum Frame Type AA NONSNA Controller Description Controller description RFCTRLENET Option BASIC Category of controller NET Attached line ENETLINE Online at IPL YES Text BLANK TCP IP Link Parameter Line description Internet address Link type Auto start link ENETLINE 50 0 1 1 ELAN YES
24. applicable only to Telnet and SSH direct connections Function key remapping and arrow key remapping can be enabled and operate independently of each other Arrow key sequences sent from the mobile device can be switched between Application mode and Cursor Key mode by the DECCKM command sent by the host The sequences are CSI 1h and CSI 1l TekTerm Client on the mobile device has a DEC Cursor Keys setting in the Keyboard Modes menu where the mode can be selected The default arrow key sequences in Psion ANSI debug format are In Cursor Key Mode 7 Bit 8 Bit Up arrow 1b A 9b A Down arrow 1b B 9b B Right arrow 1b C 9b C Left arrow 1b D 9b D ANSI Telnet Host Configuration 4 13 In Application Mode 7 Bit 8 Bit Left arrow 1b OA SHA Right arrow 1b OB 8f B Up arrow 1b OC 8f C Down arrow 1b OD 8f D These sequences are remapped by the TekTerm Server to 4 configurable sequences each a minimum of 5 hexadecimal characters long A null entry terminates the map to sequence it is not necessary to transmit nulls The default values for arrow key mappings are the 7 bit Cursor key Mode values The TekTerm Server recog nizes both the 7 bit and the 8 bit forms of the key sequences The same escape timeout applies to arrow key remapping as to function key remapping The cursor key mode setting in the mobile device is ignored by the TekTerm Server If the host changes the key sequence using DECCKM the TekTe
25. characters such as are used in escape sequences are allowed These characters can be entered using either octal or hexadecimal digits An octal escape sequence takes one of the forms Od or Odd or Oddd where each d can be any digit 0 to 7 A hexadecimal escape sequence takes one of the forms xh or xhh where each h can be 0 to 9 or any of a to f or A to F Each of these numeric escape sequences encodes one character For example the sequence 033abc becomes the character array 033 a b c 0 Values Any ASCII string Maximum 60 characters Default Press ENTER to login Notes If the octal ddd is greater than decimal 256 the code value of the represented character will be the remainder of decimal ddd 256 O is considered as a character with a code value of 0 Default Press ENTER to connect Username Prompt not The prompt string that is sent to the mobile device when the host requests a login used if username is This field is not needed when Username saved so users will not be prompted on configured page 5 10 is configured Default Username Password Prompt not The prompt string that is sent to the mobile device when the host requests a login used if password is password This field is not needed when Password saved so users will not be configured prompted on page 5 10 is configured Default Password 5 10 TekTerm Server Software User Manual Host Validation Each SSH host has a host key which is u
26. configuration 3 18 HTML HTTP options 3 13 elle aa seen sha een ee eee 3 4 Telnet protocol options 3 14 Telnet terminal naming 3 17 Telnet terminal naming buttons 3 17 5251 11 terminal xii 5555 B01 terminal xii 802 1Q common settings 15 3 proto munici n aia agen area rer 15 3 V2 settings 15 4 9010 emulation options 6 3 general hostoptions 6 3 protocol options 6 4 9010 Telnet ele Le EE 6 4 9010 TESS emulation UA AAA xii A Active Channel 13 5 Actively Negotiate with Host 2 14 3 15 CA EE 2 8 3 8 7 7 AIAG mode values 2 12 3 12 7 11 ALAN AE AAA da 2 5 3 5 7 4 Alias Interface 16 5 Alias IP Address 16 5 Alias Network Mask 16 4 Allow null character in fixed field 2 4 Allow null character in fixed fields 3 4 Allow TCP Sessions 4 12 analyze RRM groups 13 6 13 7 ANS AA ds oe he xiii arrow key mappings
27. digits then the match string for the field could be HHHH If an entry is different from the preloaded data the entry is displayed the mobile device beeps and the cursor is in the first position of the match field Now either another entry in the match field can be made or the cursor can be moved to a new field When an entry even if it does not match the host preloaded data is made in a match field this entry is sent to the host as part of the modified data from the mobile device during the next transmission A value of 0 zero disables this match field feature Values 0 to 255 Default 0 For the Psion match characters see Match Characters on page 2 12 2 10 TekTerm Server Software User Manual Hidden Match The decimal value of the special character ASCII used to tag a field to use hidden Character match mode A special character is used to mark Hidden Match fields in a TESS screen This character precedes the field contents of the Hidden Match field In hidden match fields as opposed to visible match fields the preloaded entry is not displayed in the entry field on the mobile device A value of 0 zero disables this feature Values 0 to 255 Default 0 For the Psion match characters see Match Characters on page 2 12 Serial 1 0 The decimal value of the special character ASCII used to tag a field to use serial UO mode Serial UO fields are special entry and fixed fields that accept input from and output
28. disables this feature A value of 24 causes the last entry field on each application screen to be defined as transmit upon entry Values 0 to 24 Default 0 AIAG The decimal value of the special character ASCII used to tag a field to use AIAG mode When barcode data is entered on a mobile device the mobile device searches for AIAG fields on the current page These fields can accept the special barcode data The data preloaded into the AIAG field by the application program determines whether a barcode is accepted The format of the preloaded data is lt mode gt lt AlAG prefix gt The application program distinguishes an entry field as AIAG by preceding the entry field with this special AIAG character A value of 0 zero disables this feature Values 0 to 255 Default 0 For the AIAG mode character table see AIAG Mode Values on page 3 12 5250 Telnet Host Configuration 3 9 Field Description Visible Match The decimal value of the special character ASCII used to tag a field to use Character visible match mode With field matching the host computer preloads data into an entry field Now the mobile device operator can make an entry that matches this preloaded data For visible match fields the preloaded data is displayed in the entry field on the mobile device The application program distinguishes an entry field as a match field by preceding it with a special character The special character is entered as the deci
29. from both this device and the Arbiter 1 device they assume that the network is not operating This address should be the same on both the primary and secondary Communications Servers Values Any valid IP address Default 0 0 0 0 UserScreen SNMP Parameters Screen Miscellaneous Options Screen System Configuration 17 3 User Screen This screen defines the username and password for anyone who can log in to this TekTerm Server Field Description Name A username that can be used to log into this TekTerm Server Values An ASCII string Default user Password The password that corresponds to the username This password is case sensitive Values ASCII string up to 32 characters long Default 123456 SNMP Parameters Screen This screen is used to set an option for the TekTerm Server SNMP operation Most of the SNMP options in the TekTerm Server are set through the operating system software Field Description Proxy throttling for non IP Enables throttling for SNMP queries and responses crossing Psion terminals proprietary radio networks Since these networks often use narrow band FM transmissions their maximum data rates may not be as high as those of 802 11 networks Some SNMP queries may result in large amounts of data crossing the RF networks The Proxy Throttling parameter limits the rate at which such data may be sent to prevent saturation of the RF network Values Disabled 100 byte s 500byte s
30. installed in the RRMs Terminal Radios The type of radio installed in the devices with which the RRMs communicate Values mixed TRX7370 only Default mixed Group Parameters This section lists which RRMs belong in each RRM group Field Description Combination 1 Displays the setting of Group 1 on page 13 5 Combination 2 Displays the setting of Group 2 on page 13 5 Results This section lists the results of the analysis Field Description Errors A list of problems which will cause this RRM group configuration to not work Warnings A lists of less serious problems than those in the Errors list This RRM group configuration will work but it will not be optimal Number of RRMs The number of RRMs in this group 13 8 TekTerm Server Software User Manual Field Description RRM Combination Cycle The order that the RRMs in this group are polled See Group Parameters on page 13 5 for details Poll Timeout in The same Poll Timeout must be configured on all mobile devices using this Terminals RRM group This value is a suggested setting for an averagely loaded network average load Poll Timeout in The same Poll Timeout must be configured on all mobile devices using this Terminals RRM group This value is a suggested setting for a heavily loaded network maximum load Cellular Switching and Timeplezing Radio Link Features Screen General Options
31. is the smaller of the two values A value of 1 one disables this feature Values 1 to 79 Default 8 Field Description 3274 Telnet Host Configuration 2 7 Host Print When selected an application can send data to the display on the mobile device as well as to its attached printer The text that is passed to the printer is formatted into a 24 x 80 application screen If the host can initiate the print operation the text is printed The TekTerm Server identifies the additional text as a print page by the presence of the string PRINT beginning in the 2nd column of line 13 on the 24 x 80 screen PRINT should be defined as display only text The print page is positioned below the display page of the mobile device see the following diagram The size of the print page is always the same as the display page of the mobile device assuming that in the mobile device configuration the page length is less than 12 lines When Host Print is enabled the TekTerm Server passes the print page to the mobile device after receiving the application screen from the host Display page 8 x 40 1 2 3 4 5 6 fi 8 Print Page 8 x 40 Unlike with the Passthru option when using Host Print no escape commands can be sent to the printer Support for printing must be enabled on the mobile device refer to the appropriate user manual for the mobile device for more information Default Not selected 2 8 TekTerm Server Software User Manual
32. names supplied by the host If Enable Telnet Enhancements previously called Enable Virtual Device Names is selected the TekTerm Server supplies device names for all sessions and one of the following occurs If the maximum number of sessions is greater than 1 one flexible device names are used Flexible device names have a session letter appended to the fixed portion of the device name If this maximum number of sessions is equal to 1 one device names are fixed No session letter is appended For more information see Enable Telnet Enhancements on page 3 16 First Local Terminal The port number from which the TekTerm Server makes a Telnet connection for Port the first terminal Additional Telnet sessions are assigned higher port numbers Values 1 to 32767 Default 10000 Local IP Address to The IP address of the TekTerm Server interface that connects to this host It is Bind used with the local port numbers to create a unique socket for each mobile device session Default 0 0 0 0 First Terminal Listen The lowest port number on which the TekTerm Server listens for Telnet Port connections initiated by the host When set to 0 zero this option is disabled Values 0 to 32767 Default 0 5250 Telnet Host Configuration 3 15 Field Description Actively Negotiate with When selected the TekTerm Server performs advanced negotiations with the Host host during Telnet connection Default Not selected Auto telnet l
33. not cause the screen to be transmitted A value of 0 zero disables this feature A value of 24 causes the last entry field on each application screen to be defined as transmit upon entry Values 0 to 24 Default 0 Field Overhead The maximum number of characters allowed between two fixed fields which still allows the TekTerm Server to join them into one field Sometimes the TekTerm Server will join two adjacent fixed fields and then send them as one field This reduces the overhead on the radio link For example if two fields were 4 characters apart and this parameter was 5 then these fields would be joined into one This feature affects fields with the Normal display attribute only Values 0 to 80 Default 5 HTML Function Key Mappings Screen These settings change the default function key associated with actions on the Psion mobile devices These settings cannot be overridden by settings in a TekHTML document Field Description Home The function key which requests the default page In TekHTML browser emulation this requests the Start Page See HTML Options on page 9 4 for information Back The function key which requests the previously viewed page Forward The function key which requests the next page This feature only works if the Back function key has been pressed Reset The function key which resets the connection between the mobile devices and the TekTerm Server HTML Host Configuration 9 7 Field
34. stars dee ir 10 4 remote sockets 11 4 RF modem 8 3 general options 12 3 base station 12 3 redundancy 16 4 RRM oroups ccococcccccccccc 13 3 13 6 group options RRM UE Ia 13 7 group settings RRM groups 13 5 H handler software xiv Hidden Match Character 2 10 3 10 7 9 host configuration E AAA AWE 2 17 O A E bg re 3 18 ANS AAA AA AAA WAA 4 13 Host Initialization Data 4 7 5 7 Host Po AE AAA EE eE 2 13 3 14 4 8 7 12 Host Prite 2 REEL BEE REENEN aa 2 7 3 7 7 6 Host Timeout 4 4 5 4 HP2392 u a u xii HTML emulation xii emulation options 9 4 function key mappings 9 6 general hostoptions 9 3 elle 9 4 HTML HTTP options AA WA ds 2 13 EE 3 13 IBM3179 2 Default Color 3 4 IBM3270 eo su EE AA xii EIER xii Ignore lt br gt in Preformatted Blocks 9 4 import database 18 3 Character Width on the terminal 9 4 IP Address 12 4 13 6 Is Host Fujitsu IIIA 2 4 L Last Active Session Ke
35. the Data TekTerm Server this string is sent to the mobile device Default None Host InitializationData As soon as communication is established between the host and the TekTerm Server this string is sent to the host Default None ANSI SSH Protocol Options Screen The SSH Secure Shell protocol allows full negotiation of encryption integrity key exchange compression and public key algorithms and formats All the algorithms used are well known and well established with cryp tographically sound key sizes Every SSH connection involves two authentications which are performed via public key encryption the client verifies the identity of the SSH server server authentication and the server verifies the identity of the user requesting access user authentication Once authentication takes place bulk transfer of data can proceed using private key encryption Public key encryption is used to distribute the private key to the client In this implementation the host is the SSH server and the TekTerm Server behaves as the client on behalf of each mobile device The TekTerm Server implements OpenSSH 5 8 TekTerm Server Software User Manual Field Description Host Address The IP address of the host Default None Note If the host address is not an IP address the host address must be resolvable by the TekTerm Server The TekTerm Server must be able to obtain an IP address for it For example the host name may correspond
36. the TekTerm Server 802 10 v2 Features Field Description Enabled When selected 802 1Q v2 is enabled Default Not selected Beacon UDP port The port number through which the TekTerm Server sends beacon packets This port number must be the same as the value configured in OTT on the Psion mobile devices An 802 1Q v2 beacon is a broadcast sent out to all 802 1Q v2 enabled terminals It allows the 802 1Q v2 terminals to detect the TekTerm Server and obtain the IP address of the TekTerm Server This enables a device to determine whether the TekTerm Server was rebooted and if so how to recover Values 5001 to 65535 Default 8888 Beacon Gateway The physical network interface through which the TekTerm Server sends 802 1Q Interface v2 beacon packets The TekTerm Server may have up to two Ethernet interfaces The interface is identified by its index number and IP address Values index Ethernet Default 0 Ethernet Overview Redundancy Parameters Screen General Redundancy Options Available Interfaces coxis ee gree a a A N ee A Redundancy Configuration 16 3 Overview This feature enables two similarly configured TekTerm Servers to operate in parallel One TekTerm Server is active It is the primary TekTerm Server and it manages communication to the rest of the Psion system The other TekTerm Server is the secondary server and it remains idle Both TekTe
37. the host The host must wait for this packet before sending any more screens including other PASSTHRU screens to the mobile device Refer to the user manual for the mobile device for information about setting parameters on the mobile device for pass through Default Not selected 3 6 TekTerm Server Software User Manual Field Description Procedures Legacy setting The last device to support this is the 7030 When selected the TekTerm Server can send TESS procedures to the mobile devices A TESS procedure is a group of TESS commands that can be executed by the TESS execute procedure command Default Not selected Local Legacy setting The last device to support this is the 7030 When selected the TekTerm Server can provide pages to be loaded as local TESS procedures in the mobile devices The local procedures are selected from a menu on the mobile device The mobile device can perform these procedures when it is offline Later when the mobile device is online it sends the results of these functions to the host Procedures must also be selected Default Not selected Enable TekTerm When selected the TekTerm Server uses TekTerm Screen Formatter TekTerm Screen Formatter Screen Formatter was previously known as TSF O Default Not selected Remote Print When enabled the TekTerm Server sends the print page to a mobile device whenever the mobile device requests it by sending the F17 function key from the mobile device or
38. to a serial port The application program distinguishes this field as Serial I O by preceding the field with a special character If this character precedes a fixed field the data is sent to the serial port of the mobile device If it precedes an entry field the field accepts data from the serial port of the mobile device A value of 0 zero disables this feature Values 0 to 255 Default 0 Print Line The starting line number of the print page on the application screen A value of 1 one causes the display page to be printed A value of 0 zero disables this feature Values 0 to 24 Default 0 Print Form Length The printer form length in lines Values 0 to 24 Default 0 Barcode The decimal value of the special character ASCII used to tag a field to use barcode only mode Barcode input only fields are special entry fields that only accept input from a barcode reader The application program distinguishes an entry field as barcode input only by preceding the field with a special character A value of 0 zero disables this feature Values 0 to 255 Default 0 3274 Telnet Host Configuration 2 11 Entry Line The number of the first line displayed if there is no entry field above this line on the screen and if an entry field is at or below this line The Entry Line parameter allows an automatic offset within the host screen Normally Psion mobile devices only display the upper left corner of the application screen be
39. unique number for this TekTerm Server It is used in the poll header to identify the TekTerm Server when it polls devices This is useful in systems with more than one TekTerm Server Values 0 to 255 Default 35 Polling Protocol The time in minutes that a device is allowed to be offline before the TekTerm Terminal Timeout Server removes it from the system When the device resumes activity it sends a warm initialization message to the TekTerm Server to re establish communication This parameter is used with Percent Polling Protocol Terminal Timeout it is used in narrow band systems Values 0 to 240 Default 60 14 4 TekTerm Server Software User Manual Field Description Percent Polling The time that a device is allowed to be inactive before the TekTerm Server declares Protocol Terminal it offline This time is expressed as a percentage of the Polling Protocol Terminal Timeout Timeout Thus ifthe Timeout parameter is 60 and this parameter is 75 the TekTerm Server declares a device offline after 45 minutes of inactivity 45 minutes is 75 percent of 60 minutes An offline device is still considered part of the Psion system messages to it are queued at the TekTerm Server In this example the device remains offline until it notifies the TekTerm Server that it is online or until the TekTerm Server removes it from the system entirely after 60 minutes of inactivity This parameter is used in narrow band systems Values 50 to
40. 1 3 Reading Event Log Entes ae eek 1 3 Accessing the Debug Console tin a te Leah hasse unge 1 4 Chapter 2 3274 Telnet Host Configuration OVEIVIGW ee eege ala tree 2 3 General Host Options Gcreen muwa www wanu wa muwazima uwana niwa kawawa akana za wawa kama wazawa 2 3 3274 Emulation Options Green 2 4 AO SA 2 4 ESSAY AA AA Ten Re 2 5 ek WE A aaa siini anrd at kanda iaka 2 13 3274 Telnet Protocol Options Green 2 13 3274 Telnet Terminal Naming Screen ooononicinioniniinnnconns cerrar amwamini wazia 2 15 3274 Function Key Mappings Screen aan 2 16 Typical Host ORM Gal ae ee 2 17 Line Description anistia A Ea Rae aA EAE EROE E a eE a araia 2 17 Controller Description eee 2 18 TCP IP Link vi TekTerm Server Software User Manual Chapter 3 5250 Telnet Host Configuration WEIEN geheegt italia ao Eege 3 3 General Host Options Screen aw 3 3 Emulation Options Screen 3 4 5250 6 110 EE 3 4 TESS OPIONS eree a av de nzi 3 5 AIMLA TUPO ptONS csi ee ae Re innen 3 13 5250 Telnet Protocol Options Green 3 14 5250 Telnet Terminal Naming Screen wwwwwmwewanawwnawwna nema wumanunumazumanumauuwzu maziwa anne anna 3 17 Function Key Mappings Options Screen nenne nnnnennnnnneennennnennnnn 3 18 Typical Host CON IU O ass ii ocio iio 3 18 Line Description iia 3 18 Controller Description ee 3 19 TASA AA O O 3 19 Chapter 4 ANSI Telnet Host Configuration OVE NISW nesenie naar EE 4 3 General Host Options Gcreen kuzuia u
41. 4 12 emulaton 22220 eenneeee nennen nenn xii emulation options 4 4 function key mappings 4 12 host configuration 4 13 SSHt protocol options 5 7 Telnet protocol options 4 8 Index 2 TekTerm Server Software User Manual ANSI Telnet general hostoptions 4 4 Arbiter 1 IP Address 16 5 Arbiter 2 IP Address 16 5 arrow key mappings ANSI 4 12 Arrow Key Remapping 4 6 5 6 Auto login failed login 4 11 Auto login Password 4 10 Auto login Password prompt 4 11 Auto login User ID 4 10 Auto login User ID prompt 4 10 Automatic Radio Address assignment range 11 4 14 4 Automatic Terminal Number Assignment 11 4 Auto Startup 15 3 Auto Startup 12 3 13 3 Auto telnet login Enable 2 15 3 15 4 9 7 12 Auto telnet Host 2 15 3 15 4 9 7 13 Auto telnet Terminal Prompt 4 10 Auto telnet Without User Action 2 15 3 15 4 11 7 13 Auto telnet Without User Action Timing Delay 4 11 B Background Colour
42. 74 Telnet Terminal Naming Screen e Commit Commits the entire database and returns to the Configuration Main Menu screen e Undo Discards all database changes since the last database commit and returns to the Configuration Main Menu screen Show Terminals Displays the list of currently configured terminal names 3274 Function Key Mappings Screen Use the function key list boxes to select a code that is sent to the host when the corresponding function key is pressed on the mobile device The 3274 emulator converts the mobile device function keys to Attention Identifier AID characters as shown here ENTER lt Enter gt key The Enter key on the mobile device only triggers a transmission to the host if the mobile device is configured to operate the Enter key as function O FO Consult the user manual for the mobile device for more information F1 to F24 Program Function keys lt PF1 gt to lt PF24 gt PA1 lt PA1 gt Program Access key PA2 lt PA2 gt CNCL Program Access key PA3 lt PA3 gt Program Access key CLEAR lt PA4 gt Clear Program Access key RESET lt Reset gt key SESS Opens a new Telnet session 3274 Telnet Host Configuration 2 17 Selected code AID Character SYSREQ U lt SysRq gt key lt Test gt key Typical Host Configuration Line Description Parameter Line description Option Category of line Resource name Online at IPL Vary on wait Network controller Local adapter address E
43. 8 3 Export Import Configuration Configuration Database Import Export Men 18 3 Restart TekTerm Server ia 18 3 Validate and Save Current Configuration umsssrsssnssannnnnnnnnnnnnnnannnnnnnnnnnnnnnnannnnnnnnnnnnnannnnnnen 18 3 Chapter 19 Setting Terminal Numbers on the General Host Options Screen A WAA AA aa rE E MBE AA mia ma nai MA MEN 19 3 Systems with One Hostia ee 19 3 e NOTE E 19 4 Two Hosts with No Overlapping Terminal Numbers ooooooocccccnnccnncnnccnncnoncnnnnnnnnnnnnnnnnnnncnnnononoss 19 4 Two Hosts with Overlap in Terminal Number 19 5 About this Manuals oc s G ge aoe e WA EN NN el E aa YA xi Supported Emulations and Protocols Text Conventions EmulationsandDatastreams xiii Aboutthis Guide xi About this Manual This manual contains information on the installation basic operation and configuration of TekTerm Server Chapter About this Guide an overview of this manual Chapter 1 Administering the TekTerm Server describes how to open the browser interface access the desktop start and stop TekTerm Server Chapter 2 3274 Telnet Host Configuration describes the 3274 Telnet specific settings Chapter 3 5250 Telnet Host Configuration describes the 5250 Telnet specific settings Chapter 4 ANSI Telnet Host Configuration describes the ANSI Telnet specific settings Chapter 6 9010 Telnet Host Configuration describes the 9010 Telnet specific settings Chapter 7
44. 90 Default 75 Direct TCP When selected the TekTerm Server opens a listening socket on port 9999 so that Connections for TekTerm Client can connect TekTerm f This must be enabled when redundancy is enabled Default Selected Direct TCP Check When selected the Communication Server checks for duplicate terminal numbers Duplicate Terminal among those devices connecting by Direct TCP Number This is only needed if you are manually assigning terminal IDs It is not needed if you are using automatic terminal number assignment Default Selected Expiration period in The amount of time before automatically assigned radio addresses and terminal days for Automatic numbers expire Radio Address and Terminal Number Values 1 to 365 Default 2 Automatic Radio The lower and upper allowed values of radio addresses that are assigned Address assignment automatically to narrow band or 802 1Q devices This is often enabled when Remote range Sockets or NDP is used Values lower upper 0 to 3840 For S900L range must be 1 to 50 Default lower upper 1024 2048 A range of 0 to 0 signifies that this feature is disabled Do not configure a range starting with zero and ending with a number greater than zero 802 18 Protocol au A 4 WA re ee E 3 15 3 802 1Q ConfigurationScreen 15 3 802 10CommonFeatures 15 3 Available INE 22 323 200 an Be See we el e
45. American National Standards Institute Some Psion mobile devices can accept HTML datastreams for display by a browser Other types of supported datastream provided by the host must be converted into TESS or HTML datastreams by the TekTerm Server The emulation software on the TekTerm Server can accept IBM 5250 IBM 3270 HP2392 and HTML data streams from host computers and can convert them to and from TESS TekTerm Server caches and compresses information when creating TESS datastreams to optimize performance This is most useful when transmitting across low bandwidth connections using narrow band radios The emulation software can also convert IBM 5250 and IBM 3270 datastreams to HTML datastreams so that they may be viewed through a web browser on the mobile device TekTerm Server does not cache or compress HTML datastreams ANSI datastreams from host computers are not converted by the TekTerm Server before being sent to the mobile devices The TekTerm Server can however cache and compress ANSI datastreams to conserve band width on a narrow band radio network xiv TekTerm Server Software User Manual Some hosts may have Psion handler or SDK software This software runs on the host and communicates directly with the host applications Handlers and SDKs provide TESS datastreams which are compatible with Psion mobile devices Number of Connections Maximum number of mobile devices 3840 Maximum number of base stations 254
46. Chapter 9 HTML Host Configuration 77 1 27 7 WA AA AA 9 3 General Host Options Gcreen ttrt ttnEAEAEEEAEEEEEEEEEEEEAEEEEEEEEEE Enn E Ennn EEE ent 9 3 HTML Emulation Options Green 9 4 AIME Options een 9 4 TESS OPIONSa n nn ee Wadi 9 5 HTML Function Key Mappings Screen u 242444444444RnRR nn nanHnH Hamann nn nnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnn nenn 9 6 Chapter 10 Narrowband Data Proxy NDP A OT 10 3 General Host Options SCreen iii aa 10 4 Narrowband Data Proxy Emulation Options Gcreen teers eeeeeeeeeeeeeeeeeeeeenaeeeeeeeenee 10 4 Chapter 11 Remote Socket Emulation Host Configuration TEEN eer EE 11 3 General Host Options Screen nuna nennnnnnnnnnnnnnennnnnnnnnnnennnsnnnennsnnn nenn 11 4 Other TekTerm Server Settings Associated with Remote Sockets nnnnonennnneeneeeneeereeererenreeeeeee 11 4 Mobile Device Narrow Band Configuration for Remote Sockets A 11 4 Base Station Narrow Band Configuration for Remote Sockets ccecccceeeeeeeeeeeeeeeeeneeeeeeeeeteeee 11 4 Chapter 12 Base Station Configuration OVA 12 3 General Options Screen cccccceec cece cece cece eee e eee crac n nn EErEE EEEE EE 12 3 Connectivity Options TCP IP Options for Base Station Screen nn 12 4 Chapter 13 RRM Groups Configuration LEINEN AA AA AUWA WAA MAANGA KIE NGA MNAO AA WAMA Ra Naa 13 3 General Options Screen Configure RRM Group Green 13 3 General Options Parameters ococcccccnnccnnnnnnnnnnnnnnnnnnnnnnnnnn
47. Description Use Submit Button When selected the submit button labels are used to determine the function key Labels for Function that is submitted Key ID Submit Button Label The text corresponding to the label on an on screen button This button is for Enter Key processed in the same way as the ENTER key Overview General Host Options Screen Narrowband Data Proxy Emulation Options Screen Narrowband Data Proxy NDP 10 3 Overview These screens set up the TekTerm Server to work with mobile devices running applications that use Narrow Band Data Proxy NDP Client Application Host Application TCP IP Base Mobile Station Device TekTerm Server Host Computer The client application that runs on the mobile device can make use of all the hardware and software features of that device The client application uses the APIs described in the NDP Narrow Band Data Proxy Developers Guide to open and close the connection to the TekTerm Server and to send transmissions to the TekTerm Server A plugin is required on the TekTerm Server to control the flow of data between the host application and the client application The client application on the mobile device uses the NDP APIs to communicate with this plugin The plugin also communicates using TCP IP with the host application In effect the TekTerm Server plugin relays data between the host applicatio
48. OVEIVIEW ee ie A 4 3 General Host Options Screen 4 4 ANSI EmulationOptionsScreen 4 4 ANSI Telnet Protocol Options Screen a 4 8 ANSI Function Key and Arrow Key Mappings Options Screen 4 12 Host Configuration 4 a ei et ie 4 13 ANSI Telnet Host Configuration 4 3 Overview The TekTerm Server manages the radio link caches data going to and from the mobile devices and super vises the hand off of devices as they move from one base to another Figure 4 1 Method 1 Data compression And Caching Software Terminal Software Host Application Base Terminal Station or Access Point Communications Server Host Computer Figure 4 2 Method 2 Data compression And Caching Software Terminal Software Host Application Base Terminal Station or Communications Server Access Point TSDK Software Host Computer 4 4 TekTerm Server Software User Manual General Host Options Screen Field Description Name The unique name of the host Default Unnamed Host Enabled When selected the host task is started when the TekTerm Server starts Emulation and protocol Emulation and protocol combination for this host Select ANSI Telnet Terminal range Terminal number range that communicates with this host Range 1 to 3840 For S900L range is 1 to 50 Default 1 to 32 For information on selecting the terminal
49. R NA NIN 3 4 AE 6 3 ATM ii iia 2 AA 9 4 NDP WA ee 10 4 emulations suppoerted xii Enable Colour Support 3 13 Enable Telnet Enhancements 3 16 Enable Telnet User Authentication 17 4 Enable Virtual Device Names 3 16 EntryLine 2 11 3 11 7 10 Et te EE 13 7 Escape Timeout 4 5 5 5 e EE 1 3 Expiration period in days for Automatic Radio Address and Terminal Number 14 4 export database 18 3 F Field Overhead 2 11 3 11 7 10 9 6 Field Underline Remapping 3 5 First Local Terminal Port 2 14 3 14 4 8 7 12 First Terminal 12 3 First Terminal Listen Port 2 14 3 14 4 8 7 12 8 3 Foreground Colour 2 13 3 13 Free Window Factor 13 4 13 6 Function Key Font Size 2 13 3 13 function key mappings EK nee E ane ee 2 16 A 3 18 ANS liada a 4 12 HTML re deren 3454 9 6 Function Key Remapping 4 6 5 5 G general host options II Bes een Pann MBUA ee VON 7 3 A E 2 3 A AA 3 3 9010 EA 6 3 ANSI Telnet 4 4 FUL ML aaa TAA 9 3 narrowband data proxy 10 4 NDP ii soi Aere
50. RRM is displayed beside its name on the RRM Group Menu RRMs that are not assigned to subgroups poll individually after all of the RRMs in the subgroups poll Field Description Group 1 The numbers of the RRMs in subgroup 1 Default None Group 2 The numbers of the RRMs in subgroup 2 Default None 13 6 TekTerm Server Software User Manual RRMs Screen Configure RRM Screen This screen defines a named RRM It is called from the RRM Group Menu On the RRM Group Menu the RRM number for each RRM is displayed beside its name Field Description Name The name of the RRM Default Unnamed RRM IP Address The IP address and port number of the RRM The IP address is any valid IP address the port number can range from 1024 to 32767 NOTE The base station must be in RRM mode and must have the same port number configured It listens on this port for incoming data from the TekTerm Server which includes the TekTerm Server IP address Default 0 0 0 0 16132 Analyze Screen Analyze RRM Group Screen This screen displays the configured parameters for the selected RRM group on this Communications Server It also displays errors and warnings about things that could potentially cause problems on the network This screen is opened by selecting Analyze on the RRM Group Menu screen General Parameters Field Description Name The name of the RRM group Radio Link Protocol The protocol used by the RRM group named in Name Pol
51. S900L 1 to 50 Default 1 For information on selecting this value for non standard configurations see 9500 Series Communications Servers Setting Terminal Numbers on the Base Station General Options Screen on IngenuityWorking Message Size The size in number of characters of the largest single message that can be passed to a device in a single packet Longer messages are broken into several packets Values Legacy 900Mhz and 2 4 GHz Wireless LAN protocol 32 to 380 Values Narrow band protocol 32 to 116 Default 100 Note Operate in Cellular Mode must be selected See the Radio Link Features Screen General Options on page 14 3 for more information Auto Startup When selected the TekTerm Server commands the base station to start polling as soon as the base station connection has been established Default Selected Note Ifthe TekTerm Server is configured as a slave controller the Auto Startup parameter should be disabled 12 4 TekTerm Server Software User Manual Connectivity Options TCP IP Options for Base Station Screen Field Description IP Address The IP address and port number for the base station Values IP address Any valid IP address Values Port number 1024 to 32767 Default IP Address 0 0 0 0 Port 16100 Note The only time that the default port needs to be changed is when the TekTerm Server is the slave of another TekTerm Server OVEIVIEW Lu aa AE d E e e A NEE ee ee ee ee N 13 3 Genera
52. Smart echo must also be enabled on the mobile device Default Selected Function Key When selected the TekTerm Server remaps the function keys for this host Remapping connection as defined in the ANSI Function Key and Arrow Key Mappings Options Screen Default Not selected For information on function key remapping see Function Keys on page 5 12 5 6 TekTerm Server Software User Manual Field Description Arrow Key Remapping When selected the TekTerm Server remaps the arrow keys for this host connection as defined in the ANSI Function Key and Arrow Key Mappings Options Screen Default Not selected For information on arrow key remapping see Arrow Keys on page 5 12 Page Saving When selected the TekTerm Server uses page saving reducing data transmitted to the mobile devices The TekTerm Server maintains an image of each page stored on the mobile device After receiving an application screen the TekTerm Server tries to match the screen with a stored page If the page is already in the mobile device the TekTerm Server instructs the mobile device to redisplay its stored copy of the page minimal data is sent across the radio link for that page If the TekTerm Server finds no match for the page the complete page is sent to the mobile device If a page is close enough to a saved one close enough being defined by the Threshold setting then only the redisplayed and the changed data are sent resulting in reduced data transmissio
53. TekTerm Server Software TEKTERM SERVER SOFTWARE USER MANUAL 8000281 001 Rev A April 2015 ii TekTerm Server Software User Manual No part of this publication may be reproduced or used in any form or by any electrical or mechanical means without permission in writing from Zebra This includes electronic or mechanical means such as photocopying recording or information storage and retrieval systems The material in this manual is subject to change without notice The software is provided strictly on an as is basis All software including firmware furnished to the user is on a licensed basis Zebra grants to the user a non transferable and non exclusive license to use each software or firmware program delivered hereunder licensed program Except as noted below such license may not be assigned sublicensed or otherwise transferred by the user without prior written consent of Zebra No right to copy a licensed program in whole or in part is granted except as permitted under copyright law The user shall not modify merge or incorporate any form or portion of a licensed program with other program material create a derivative work from a licensed program or use a licensed program in a network without written permission from Zebra The user agrees to maintain Zebra s copyright notice on the licensed programs delivered hereunder and to include the same on any authorized copies it makes in whole or in part The user agrees not to
54. This utility is described in Analyze Screen Analyze RRM Group Screen on page 13 6 Each RRM must be a member of an RRM group there may be more than one RRM group configured on the TekTerm Server An RRM group may contain only one RRM and may contain a maximum of four RRMs General Options Screen Configure RRM Group Screen This screen is used to configure a named RRM group and to list the terminals that are included in the RRM group General Options Parameters Field Description Name The name of an RRM group Default Unnamed RRM Group Communication Protocol The protocol to be used for the connection to this RRM group Values TCP IP Default TCP IP Enabled When selected this RRM group is active Default Selected Auto Startup When selected the TekTerm Server starts polling this RRM group as soon as it starts up Default Selected Polling Protocol Parameters WARNING _ The default settings for the parameters in this section are suitable for almost all situ ations It is not advisable to make changes to them 13 4 TekTerm Server Software User Manual Field Description Number of Poll Windows The number of poll windows in which the RRM listens for terminal responses after sending a poll Values 2 to 4 Default 3 Size of Poll Windows The size of the poll windows in which the RRMs of this RRM group listen for terminal replies Values 5 to 32 Default 8 Maximum Message The size of the largest message segme
55. aa 15 4 802 10 V2 Feal res ten REP a II UU en 15 4 802 10 v1 and v2 Features Configuration 15 3 802 10 Protocol 802 1Q is a Psion proprietary protocol optimized to operate on a wireless LAN 802 1Q protocol is available in two versions 802 1Qv1 and 802 1Qv2 Each mobile device must use only one of these protocols 802 1Qv1 is an efficient proprietary non TCP IP over the air protocol that eliminates the need for a TCP IP stack on a device Psion base stations fitted with 802 11 radios convert it to the protocols of the wired network 802 1Qv2 protocol is an enhanced version of the 802 1Qv1 protocol that transports packets over the UDP layer It provides all 802 1Qv1 capabilities It also allows the mobile device to use a TCP IP stack and communicate with the TekTerm Server through any third party 802 11 access point 802 10 Configuration Screen 802 10 Common Features Field Description Auto Startup When selected this parameter enables the Psion 802 1Q protocol v1 or v2 to start automatically when the TekTerm Server is rebooted Default Not selected Terminal Offline Timeout The time in minutes before the TekTerm Server declares an 802 1Q terminal offline Values 1 to 240 Default 5 Beacon Period The duration in seconds of a beacon Values 1 to 20 Default 2 15 4 TekTerm Server Software User Manual Available Interfaces This section of the screen displays the network interfaces that are available to
56. age to the mobile device containing a link to the start page The user can then request the start page later by following the link The scheme the http part must be provided with the web address of the start page The TekHTML emulator expects it and does not provide it if it is not specified The mobile device requests the start page when the user presses the Home function key Default http See Home on page 9 6 for information on selecting the Home function key Character Width onthe The width in pixels of a single character on the mobile device screen The terminal in Pixels emulator uses this width value when formatting web pages to fit the mobile device screen Values 1 to 10 Default 8 Ignore lt br gt in When selected line breaks lt BR gt tags inside lt PRE gt blocks are ignored by Preformatted Blocks the TekTerm Server Default Selected Return Pre Filled Data When selected data that is pre filled in entry fields is returned to the host even if it to Host is not modified Default Selected HTML Host Configuration 9 5 TESS Options Field Description Passthru When selected the TekTerm Server allows the host to send data directly to the serial port of the mobile device This is commonly used for printing Passthru is implemented using attributes on the BODY element specific to Psion See TekHTML Support on 9500 Series Communications Servers on IngenuityWorking for information Default Not selec
57. ange is 1 to 50 Default 1 to 32 For information on selecting the terminal range see Chapter 19 Setting Terminal Numbers on the General Host Options Screen Auto terminal number When selected TekTerm Server assigns terminal numbers to all mobile devices assignment not that use this session supported by Direct ji ji ji TCP When not selected terminal numbers must be assigned on the mobile devices Default Selected Telnet Protocol Options Screen Field Description First Terminal Listen The lowest port number on which the TekTerm Server listens for Telnet Port connections initiated by the host When set to 0 zero this option is disabled Values 0 to 32767 Default 0 UE WA ee Bee WA 9 3 General Host Options Screen 9 3 HTML Emulation Options Screen 9 4 FULML Options s aa ida EE a a See ee ts 9 4 TESS Opuons aa a wa REY A ach 9 5 HTML Function Key Mappings Screen 9 6 HTML Host Configuration 9 3 Overview The HTML emulation converts HTML pages received from the host into TESS data streams which are trans mitted to the Psion mobile devices A limited set of HTML elements and attributes is supported by the TekHTML emulation on the TekTerm Server For information on developing TekHTML documents see TekHTML Support on 9500 Series Communications Servers on IngenuityWorking Data compression An
58. ape sequences encodes one character For example the sequence 033abc becomes the character array 033 a b c 0 Values Any ASCII string Maximum 60 characters Default Press ENTER to login Notes If the octal ddd is greater than decimal 256 the code value of the represented character will be the remainder of decimal ddd 256 O is considered as a character with a code value of 0 Auto login User ID The user ID presented by the TekTerm Server to the host for the auto login sessions Values Any ASCII string acceptable to the host Maximum 15 characters Default None Auto login Password The password presented by the TekTerm Server to the host for the auto login sessions Values Any ASCII string acceptable to the host Maximum 15 characters Default None Auto login User ID The TekTerm Server compares this text to the text presented to it by the host prompt When they match the TekTerm Server assumes that the host has just sent its request for a user name and it sends the username specified in Auto login User ID to the host Values Any ASCII string that does not include spaces Maximum 15 characters Default gin Notes The match string should be as short as possible yet long enough to uniquely identify the username prompt ANSI Telnet Host Configuration 4 11 Auto login Password The TekTerm Server compares this text to the text presented to it by the host prompt When they match the TekTerm Server assumes th
59. at the host has just sent its request for a password and it sends the password specified in Auto login Password to the host Values Any ASCII string that does not include space characters Maximum 15 characters Default word Notes The match string should be as short as possible yet long enough to uniquely identify the password prompt Auto login failed login The TekTerm Server compares this text to the text presented to it by the host When they match the TekTerm Server assumes that the host has just sent a string informing the mobile device of a failed login attempt The TekTerm Server then presents the Auto telnet Terminal Prompt on the screen of the mobile device to request the user to login manually Values Any ASCII string that does not include spaces Maximum 15 characters Default incorrect Note The match string should be as short as possible yet long enough to uniquely identify the failed login prompt Auto telnet Without When selected the TekTerm Server attempts to connect to the host as soon as a User Action mobile device initializes and it attempts to reconnect if the Telnet session closes Default Selected Auto telnet Without The number of milliseconds between auto Telnet connection requests sent to User Action Timing the host Delay All requests to connect without user action are queued and are processed with this delay between requests This prevents flooding the host with connection and logins when t
60. ation 2 9 Field Description Visible Match The decimal value of the special character ASCII used to tag a field to use visible Character match mode With field matching the host computer preloads data into an entry field Now the mobile device operator can make an entry that matches this preloaded data For visible match fields the preloaded data is displayed in the entry field on the mobile device The application program distinguishes an entry field as a match field by preceding it with a special character The special character is entered as the decimal character code for one of the first 127 ASCII characters For example assume that the gt character ASCII decimal character code 62 is defined for visible match fields This character must immediately precede the entry field Part gt The field Part gt includes the character gt and is followed by the part number entry field on the screen If any other character was chosen as the last character of the text the entry field would not be a match field The preloaded data sent to a mobile device may consist of the exact characters special match characters or a combination of the two For example suppose you wish to preload an entry field with a part number Ifthe exact part number is known you may preload the field with that part number If more flexibility is required and part numbers always begin with two alphabetic characters followed by a hyphen character and four
61. ature Values 0 to 24 Default 0 Print Form Length The printer form length in lines Values 0 to 24 Default 0 Barcode The decimal value of the special character ASCII used to tag a field to use barcode only mode Barcode input only fields are special entry fields that only accept input from a barcode reader The application program distinguishes an entry field as barcode input only by preceding the field with a special character A value of 0 zero disables this feature Values 0 to 255 Default 0 5250 Telnet Host Configuration 3 11 Entry Line The number of the first line displayed if there is no entry field above this line on the screen and if an entry field is at or below this line The Entry Line parameter allows an automatic offset within the host screen Normally Psion mobile devices only display the upper left corner of the application screen because of their smaller display size Values 0 to 24 Default 0 Field Overhead The maximum number of characters allowed between two fixed fields which still allows the TekTerm Server to join them into one field Sometimes the TekTerm Server will join two adjacent fixed fields and then send them as one field This reduces the overhead on the radio link For example if two fields were 4 characters apart and this parameter was 5 then these fields would be joined into one This feature affects fields with the Normal display attribute only Values 0 to 80 Default 5
62. cause of their smaller display size Values 0 to 24 Default 0 Field Overhead The maximum number of characters allowed between two fixed fields which still allows the TekTerm Server to join them into one field Sometimes the TekTerm Server will join two adjacent fixed fields and then send them as one field This reduces the overhead on the radio link For example if two fields were 4 characters apart and this parameter was 5 then these fields would be joined into one This feature affects fields with the Normal display attribute only Values 0 to 80 Default 5 Command Region These two pairs of text boxes define a region of the host screen which the TekTerm Server examines for the presence of reserved commande The first text box of each pair contains the row number the second contains the column number These four numbers represent the row and column addresses of the upper left corner and the lower right corner of the command region To define the last two lines of the host screen as the command region enter 23 1 24 80 The only commands supported in the command region are ALARM and FONT e When the word ALARM is placed anywhere within the command region the TekTerm Server sends a TESS beep command to the mobile device When the word FONT is placed anywhere within the command region and followed by a number the font code the TekTerm Server sends the appropriate TESS Change Font command to the mobile device For fon
63. ces from the Administrative Tools menu 2 Select TekTerm Server Watchdog 3 Select Restart Reading Event Log Entries The TekTerm Server logs events that can be viewed with the Windows Event Viewer The following events are logged e The watchdog task is started The watchdog restarts another task from crash or exit or from checkpoint failure or timeout The user manually starts terminates or restarts a process through the watchdog 1 4 TekTerm Server Software User Manual e There is a change of redundancy status for the TekTerm Server secondary to primary The TekTerm Server starts up as primary or secondary View the logged events 1 In Control Panel select Event Viewer from the Administrative Tools menu 2 Select Application events 3 To view more information on a selected event double click the entry for the event Accessing the Debug Console The TekTerm Server provides a text mode debug console By default no username is needed to open this console however the TekTerm Server may be configured to require a username and password For informa tion on setting a username and password see User Screen on page 17 3 To make the username and pass word required see Enable Telnet User Authentication on page 17 4 Connecting locally Use the following Telnet localhost 9523 Connecting remotely Use the following Telnet lt IP address gt 9523 Where lt IP address gt is the IP address of the computer r
64. d Caching Software Host Application Emulation Software Base Terminal Station or Access Communications Server Point HTTP Server Host Computer General Host Options Screen Field Description Name The unique name of the host Default Unnamed Host Enabled When selected the host task is started when the TekTerm Server starts Emulation and protocol Emulation and protocol combination for this host Select HTML Terminal range Terminal number range that communicates with this host Range 1 to 3840 For S900L range is 1 to 50 Default 1 to 32 For information on selecting the terminal range see Chapter 19 Setting Terminal Numbers on the General Host Options Screen 9 4 TekTerm Server Software User Manual HTML Emulation Options Screen HTML Options These settings configure the TekHTML emulation on the TekTerm Server Field Description Screen Size row x col The number of lines on the mobile device screen and the number of characters in each line If you enter an invalid range an error message results Changes are not written to the database and you can enter a valid range Rows 1 to 40 Columns 1 to 132 Default 24 x 80 Start Page The web address or URL of the start page of the HTML emulator The TekTerm Server retrieves this page parses it into TESS and sends the TESS data stream by default to each mobile device If the TekTerm Server cannot retrieve the start page it sends a simple p
65. d entry is not displayed in the entry field on the mobile device A value of 0 zero disables this feature Values 0 to 255 Default 0 For the Psion match characters see Match Characters on page 7 11 Serial 1 0 The decimal value of the special character ASCII used to tag a field to use serial UO mode Serial UO fields are special entry and fixed fields that accept input from and output to a serial port The application program distinguishes this field as Serial UO by preceding the field with a special character If this character precedes a fixed field the data is sent to the serial port of the mobile device If it precedes an entry field the field accepts data from the serial port of the mobile device A value of 0 zero disables this feature Values 0 to 255 Default 0 Print Line The starting line number of the print page on the application screen A value of 1 one causes the display page to be printed A value of 0 zero disables this feature Values 0 to 24 Default 0 Print Form Length The printer form length in lines Values 0 to 24 Default 0 Barcode The decimal value of the special character ASCII used to tag a field to use barcode only mode Barcode input only fields are special entry fields that only accept input from a barcode reader The application program distinguishes an entry field as barcode input only by preceding the field with a special character A value of 0 zero disables this f
66. decompile disassemble decode or reverse engineer any licensed program delivered to the user or any portion thereof Zebra reserves the right to make changes to any software or product to improve reliability function or design Zebra does not assume any product liability arising out of or in connection with the application or use of any product circuit or application described herein No license is granted either expressiy or by implication estoppel or otherwise under any Zebra Inc intellectual property rights An implied license only exists for equipment circuits and subsystems contained in Zebra products Warranty iv TekTerm Server Software User Manual Revision History Changes to the original guide are listed below Change Date Description Rev 001A 4 2015 About this Manual A xi Supported Emulations and Protocols ccccccecccecceee cece cece cette ee eae anna xii Text CONVENTIONS coccccccccnnnnnnnnnnononononnnnnnn cnn rn xii Emulations and Datasireams uwiii wu mwaume xiii Number Of Connechons cnn nen nnnnnnnnnnnnnnnnnnrnnnnnnnnnnnnnnnno xiv Chapter 1 Administering the TekTerm Server Accessing the TekTerm Server Browser Interface cccccseeeenseeeeeeseeeeceeeeeeeeeeeeteneeeeeeeeeeeeeeeees 1 3 ACCESSING Windows DESKIOD EE 1 3 Stopping the TekTerm Serve wawi mazutima wamuumiza wazinzi 1 3 Restarting the TekTerm Server oocoonnniccionononinicccccronrn nennen
67. ding character 3274 Telnet Host Configuration 2 13 HTML HTTP Options Field Description Foreground Colour This is the foreground colour for the text that the TekTerm Server HTTP server sends to mobile devices connecting via HTTP The choices are the 16 predefined HTML colour names Values Aqua Black Blue Fuchsia Gray Green Lime Maroon Navy Olive Purple Red Silver Teal White Yellow Default Black Background Colour This is the background colour the colour of the HTML page that the TekTerm Server HTTP server sends to mobile devices connecting via HTTP The choices are the 16 predefined HTML colour names Values Aqua Black Blue Fuchsia Gray Green Lime Maroon Navy Olive Purple Red Silver Teal White Yellow Default Silver User Data Font Size This is the value for the HTML font size attribute that is applied to user data on the browser screen Values 1 2 3 4 5 6 7 Default 3 Function Key Font This is the size of the font that is used on the function key buttons on the Size browser screen Values 4pt 6pt 8pt 10pt 12pt 14pt Default 8pt Enable TekTerm When selected the TekTerm Server uses TekTerm Screen Formatter TekTerm Screen Formatter Screen Formatter was previously called TSF O Default Selected 3274 Telnet Protocol Options Screen Field Description Terminal Type The type of terminal to be emulated by the TekTerm Server Values IBM 2378 2 IBM 3278 2 E Defau
68. e can perform these procedures when it is offline Later when the mobile device is online it sends the results of these functions to the host Procedures must also be selected Default Not selected Enable TekTerm When selected the TekTerm Server uses TekTerm Screen Formatter TekTerm Screen Formatter Screen Formatter was previously known as TSF O Default Not selected Remote Print When enabled the TekTerm Server sends the print page to a mobile device whenever the mobile device requests it by sending the F17 function key from the mobile device or the PRINT key on older mobile devices The TekTerm Server sends the function response back to the host Support for printing must be enabled on the mobile device refer to the appropriate user manual for the mobile device for more information Default Not selected Pages The number of host screens or pages stored on the mobile device The TekTerm Server maintains an image of each page stored on the mobile device After receiving an application screen the TekTerm Server tries to match the screen with a stored page If a similar page is already in the mobile device memory the TekTerm Server instructs the mobile device to re display its copy of the page only the necessary changes are sent from the TekTerm Server If no match is found the complete page is sent to the mobile device There is a corresponding parameter on the mobile device itself and the actual number of saved pages
69. e device may consist of the exact characters special match characters or a combination of the two For example suppose you wish to preload an entry field with a part number If the exact part number is known you may preload the field with that part number If more flexibility is required and part numbers always begin with two alphabetic characters followed by a hyphen character and four digits then the match string for the field could be HHHH If an entry is different from the preloaded data the entry is displayed the mobile device beeps and the cursor is in the first position of the match field Now either another entry in the match field can be made or the cursor can be moved to a new field When an entry even if it does not match the host preloaded data is made in a match field this entry is sent to the host as part of the modified data from the mobile device during the next transmission A value of 0 zero disables this match field feature Values 0 to 255 Default 0 For the Psion match characters see Match Characters on page 7 11 2392 Telnet Host Configuration 7 9 Field Description Hidden Match The decimal value of the special character ASCII used to tag a field to use Character hidden match mode A special character is used to mark Hidden Match fields in a TESS screen This character precedes the field contents of the Hidden Match field In hidden match fields as opposed to visible match fields the preloade
70. e device may start anywhere below the first line Attributes occupy a position in the screen buffer An attribute placed between column 2 and the end ofthe word PASSTHRU pushes all following characters one position to the right Therefore any required attributes should occupy column 1 of the first line just preceding the word PASSTHRU For example column line 1 line 2 where is an attribute When the TekTerm Server finishes sending the data to the printer attached to the mobile device it sends a packet containing only a Record Separator Ox1e character to the host The host must wait for this packet before sending any more screens including other PASSTHRU screens to the mobile device Refer to the user manual for the mobile device for information about setting parameters on the mobile device for pass througn Default Not selected Procedures Legacy setting The last device to support this is the 7030 When selected the TekTerm Server can send TESS procedures to the mobile devices A TESS procedure is a group of TESS commands that can be executed by the TESS execute procedure command Default Not selected 2 6 TekTerm Server Software User Manual Field Description Local Legacy setting The last device to support this is the 7030 When selected the TekTerm Server can provide pages to be loaded as local TESS procedures in the mobile devices The local procedures are selected from a menu on the mobile device The mobile devic
71. e devices They are configured once on the TekTerm Server the TekTerm Server then downloads them to the RRMs in the group WARNING The radio parameters are pre configured for your system and should not be changed without a proper understanding of how it affects the radio link Field Description Sync Delay The number of delay characters inserted between the RRM transmission and the first response window Values 3 to 45 Default 28 Remote Txon The number of fill characters sent by the devices to their radios before the devices send message data Values 3 to 60 Default 13 Active Channel The radio channel used by all the RRMs in the RRM group Values 1 to 20 Default 1 Group Parameters These list the individual RRMs in each subgroup If the coverage areas of two or more of the RRMs in this RRM group do not overlap the non overlapping RRMs may be assigned to the same subgroup They then poll at the same time This improves system response time and reduces the amount of signalling on the network As an example ifthe RRM group has 3 RRMs and RRMs 1 and 3 do not overlap RRMs 1 and 3 may be placed in one subgroup They then poll simultaneously RRM 2 may be placed in another subgroup Polling then alternates between the two subgroups To configure a subgroup place the numbers of the RRMs in the text box for that subgroup For instance 13 in the text box for subgroup 1 places RRMs 1 and 3 in that subgroup The number for each
72. e only commands supported in the command region are ALARM and FONT e When the word ALARM is placed anywhere within the command region the TekTerm Server sends a TESS beep command to the mobile device e When the word FONT is placed anywhere within the command region and followed by a number the font code the TekTerm Server sends the appropriate TESS Change Font command to the mobile device For font codes see Font Code List for Open TekTerm on IngenuityWorking Font codes are only required for versions of OTT before version D Rows 0 to 24 Columns 0 to 80 Default 0 0 0 0 2392 Telnet Host Configuration 7 11 AIAG Mode Values The mode character is derived by starting with the decimal value 43 ASCII character 0 zero and adding the appropriate value from the table below Code Description 1 Prevent the AlAG prefix from being displayed 2 Prevent the AIAG prefix from being sent to the host 4 Cause a transmission to the host when all AIAG fields with this mode set are filled The transmission is sent by a Function O FO code 8 Allow overwriting of previously entered data 16 Start the search for a matching AIAG field at the current cursor position Otherwise the cursor starts at the top of the page For example the symbol is used to apply the cursor matching function since adding 16 to 48 results in decimal value 64 which is the ASCII value for the character Match Characters Match Use Character
73. eature Values 0 to 255 Default 0 7 10 TekTerm Server Software User Manual Entry Line The number of the first line displayed if there is no entry field above this line on the screen and if an entry field is at or below this line The Entry Line parameter allows an automatic offset within the host screen Normally Psion mobile devices only display the upper left corner of the application screen because of their smaller display size Values 0 to 24 Default 0 Field Overhead The maximum number of characters allowed between two fixed fields which still allows the TekTerm Server to join them into one field Sometimes the TekTerm Server will join two adjacent fixed fields and then send them as one field This reduces the overhead on the radio link For example if two fields were 4 characters apart and this parameter was 5 then these fields would be joined into one This feature affects fields with the Normal display attribute only Values 0 to 80 Default 5 Command Region These two pairs of text boxes define a region of the host screen which the TekTerm Server examines for the presence of reserved commands The first text box of each pair contains the row number the second contains the column number These four numbers represent the row and column addresses of the upper left corner and the lower right corner of the command region To define the last two lines of the host screen as the command region enter 23 1 24 80 Th
74. ect General Host Options 9010 Emulation Options 9010 Protocol OptionsScreen 9010 Telnet Host Configuration 6 3 General Host Options Field Description Name The unique name of the host Default Unnamed Host Enabled When selected the host task is started when the TekTerm Server starts Emulation and protocol Emulation and protocol combination for this host Select 9010 Telnet Terminal range Terminal number range that communicates with this host Range 1 to 3840 For S900L range is 1 to 50 Default 1 to 32 For information on selecting the terminal range see Chapter 19 Setting Terminal Numbers on the General Host Options Screen Auto terminal number When selected TekTerm Server assigns terminal numbers to all mobile devices assignment not that use this session supported by Direct ji ji ji TCP When not selected terminal numbers must be assigned on the mobile devices Default Selected 9010 Emulation Options Field Description Refrain from sending Narrow band and 802 1Q v1 only When selected the TekTerm Server does not On line amp Off line forward terminal offline and terminal online messages from the base station to messages the host Default Not selected 6 4 TekTerm Server Software User Manual 9010 Protocol Options Screen 9010 Telnet Options Field Description Monitor Polls When selected the TekTerm Server mo
75. ed to terminal names when Configure LU names is set This prefix can be up to five alphanumeric characters Default None Send IAC Interrupt When selected the TekTerm Server sends the IAC Interrupt Process request to the Process as a host as a 3274 System Request System Request Default Not selected Send IAC Break as When selected the TekTerm Server sends the IAC Break request to the host as a a Attention Key 3274 Attention Key Default Not selected 3274 Telnet Host Configuration 2 15 Field Description Auto telnet login When enabled the host connection is automatically selected by the Auto te net Enable Host parameter When disabled Telnet sessions from the mobile devices must be manually initiated Values DISABLE AUTO TELNET Default DISABLE Auto telnet Host The name or the IP address of the host to which auto Telnet requests are directed Any host name which can be used at the TCP gt prompt on the mobile device may be used here Default None Note The host name must be resolvable by the TekTerm Server The TekTerm Server must be able to obtain an IP address for it For example the host name may correspond to an entry in the TekTerm Server host table or the TekTerm Server may be able to query a domain name server Auto telnet Without When selected the TekTerm Server attempts to connect to the host as soon as a User Action mobile device initializes and it attempts to reconnect if the Telnet session closes
76. equested name is not available on the host the session letter increments until a successful connection is established Fixed names are created when the maximum number of sessions is set to 1 one In this case each device name has a maximum length of 10 fixed characters There is no session letter appended If the requested name is not available on the host the mobile device displays a message instructing the user to contact the system administrator Default Not selected For more information see 5250 Telnet Terminal Naming Screen on page 3 17 and Device Name Prefix on page 3 15 Display Emulation The codepage and keyboard type that are configured on the host or server Select Support Code page from the drop down list This setting must be identical to the host setting so that Character Set the correct characters are sent to the host application Keyboard Type Default 037 USA Canada 37 697 USB 5250 Telnet Host Configuration 3 17 5250 Telnet Terminal Naming Screen Field Description Terminal number The number of the terminal which receives the name in Terminal name Values 1 to lt number of configured terminals gt Default 1 Terminal name A virtual device name for the terminal It can include uppercase letters A to Z numbers 0 to 9 and the special characters and Lower case letters are accepted and translated to uppercase characters The prefix must not begin with a number When using flexible device nam
77. equivalent 8 bit character compressing the data For example the escape sequence ESC is converted to CSI Default Not selected ANSI SSH Host Configuration 5 7 Field Description Lower Character Set This is the character set to be used for the first 128 character codes decimal 0 to GL 127 hex 00 to 7F This should be set to the same character set as selected in the mobile devices This parameter is only used when page saving is enabled Available character sets are ASCII DEC Multi DEC_Graphical British DEC Danish DEC Dutch DEC Finnish DEC French DEC French CDN DEC German DEC Italian DEC Portuagal DEC Spanish DEC Swedish DEC Swiss DEC Arabic Thai and a Not Listed selection Default ASCII Upper Character Set This is the character set to be used for the second 128 character codes decimal GR 128 to 255 hex 80 to FF This should be set to the same character set as selected in the mobile devices This parameter is only used when page saving is enabled Available character sets are ASCII DEC Multi DEC_Graphical British DEC Danish DEC Dutch DEC Finnish DEC French DEC French CDN DEC German DEC Italian DEC Portuagal DEC Spanish DEC Swedish DEC Swiss DEC Arabic Thai Latin Latin 2 Latin 3 Latin 4 Latin 5 Latin 6 Cyrillic ISO Arabic ISO Greek ISO Hebrew ISO and Thai ISO Default DEC_Multi Terminal Initialization As soon as communication is established between a mobile device and
78. er instructs the mobile device to re display its copy of the page only the necessary changes are sent from the TekTerm Server If no match is found the complete page is sent to the mobile device There is a corresponding parameter on the mobile device itself and the actual number of saved pages is the smaller of the two values A value of 1 one disables this feature Values 1 to 79 Default 8 Transmit Line When enabled all modified data on the mobile device is automatically transmitted when the operator enters data into an entry field on or above this line The value in this text box specifies the line on the screen which is designated as the transmit line The last entry field on or above the transmit line on the screen is identified as the field which will cause all modified data to be sent to the host Any entry fields that exist on lines below the transmit line will not cause the screen to be transmitted A value of 0 zero disables this feature A value of 24 causes the last entry field on each application screen to be defined as transmit upon entry Values 0 to 24 Default 0 AIAG The decimal value of the special character ASCII used to tag a field to use AIAG mode When barcode data is entered on a mobile device the mobile device searches for AIAG fields on the current page These fields can accept the special barcode data The data preloaded into the AIAG field by the application program determines whether a barc
79. erminal ID 1 Settings are as follows In the Host General Options for Host1 Terminal Range 1 to 9 In the Host General Options for Host2 Terminal Range 10 to 20 In the Base Station General Options for Basel First Terminal 1 Setting Terminal Numbers on the General Host Options Screen 19 5 In this example no physical terminals fall within the ranges of both Host1 and Host2 Thus no terminal can communicate with both hosts Terminals 1 to 9 Communicate with Host1 Terminal 1 is mapped to Host1 session 1 Terminal 9 is mapped to Host1 session 9 Terminals 10 to 20 Communicate with Host2 Terminal 10 is mapped to Host2 session 1 Terminal 20 is mapped to Host2 session 11 As an example Terminal 13 is the Host2 session 4 Two Hosts with Overlap in Terminal Numbers AN IMPORTANT You cannot overlap an ANSI host with another ANSI host or any other type of host Host Terminal Range on Communications Server 1 2 34567 8 9 10 1 12 13 14 15 16 17 18 19 20 2 2 3 4 5 6 7 8 9 J10 11 12 13 J14 15 J16 17 18 19 20 Host1 2 2 3 4 5 6 7 8 9 10 11 Host2 QOOOOOOOOCOOOCOOUOO OO Baset Terminal ID Numbers Terminal ID 1 Terminal ID 20 Settings are as follows In the Host General Options for Host Terminal Range 1 to 20 In the Host General Options for Host2 Terminal Range 10 to 20 In the Base Station General Options for Base 1 First Terminal 1 Terminals 1 to 9 Communicate with Host1 only Terminal
80. es maximum number of sessions is greater than 1 the maximum length for the terminal name is 9 characters More characters results in a validation error Values 1 to 10 characters Default None Buttons Button Description Show Set Displays the virtual device name associated with the terminal number If you have just entered a terminal number and virtual device name press this button to add the terminal number and virtual device name to the list of configured terminals Note Ifa name disappears from the Terminal Name text box after the Show Set button has been pressed the last terminal number entered has not been registered by the TekTerm Server system and the name has been saved to the previous terminal number It is recommended that the terminal names be frequently checked during entry through the Terminal Names screen Delete Deletes the currently displayed terminal number and virtual device name from the list OK Saves changes to the database and returns to the 5250 Telnet Protocol Options Screen 3 18 TekTerm Server Software User Manual Validates with the option to save the changes to the TekTerm Server database Validate Show Terminals On the Validation Results screen after reviewing any error messages you can click one of the following Cancel Returns to the Configuration Main Menu Screen e Commit Commits the entire database and returns to the Configuration Main Menu screen
81. esponding to their network interface and hardware address The primary TekTerm Server presents the alias address to the network as well as its own unique IP address The secondary TekTerm Server only presents its own unique IP address to the network When the secondary TekTerm Server becomes the primary it starts to use the alias IP address The old primary TekTerm Server which becomes the secondary stops using the alias IP address Devices on the network which communicate directly with the Psion network TekTerm Server IP address such as devices using Direct TCP may communicate with the alias IP address They will then communicate with whichever of the two redundant TekTerm Servers is the primary Values Any valid IP address Default 0 0 0 0 Note Direct TCP Connections for TekTerm must be selected See General Options on page 14 3 on Radio Link Features screen for more information Arbiter 1 IP Address The address of a device on the network which is known to be reliable Both TekTerm Servers ping this device if they receive no reply from this device or the Arbiter 2 device they assume that the network is not operating This address should be the same on both the primary and secondary Communications Servers Values Any valid IP address Default 127 0 0 1 Arbiter 2 IP Address Optional The address of a device on the network which is known to be reliable Both Communications Servers ping this device If they receive no reply
82. figured Password saved so The password sent to the host when the host requests it The same password is users will not be provided for all mobile devices using this connection prompted Default None Note This field is not needed if Password Prompt not used if password is configured on page 5 9 is configured ANSI SSH Host Configuration 5 11 Field Description Public key When selected the TekTerm Server attempts public key authentication authentication enabled SSH2 only Default Not selected Private key file name The filename and its path where the private host key is stored on the and path TekTerm Server The private host key is obtained from the host administrator Default None Private key The passphrase used to protect the private key passphrase The private key passphrase is obtained from the host administrator Default None Keyboard Interactive When selected keyboard interactive authentication is enabled authentication enabled fi EEN When selected the three sets of prompt and response in the following fields are active Default Selected Host Prompt 1 When this string is received from the host the string in Auto Response 1 is sent to the host Default None Auto Response 1 See Host Prompt 1 Default None Host Prompt 2 When this string is received from the host the string in Auto Response 2 is sent to the host Default None Auto Response 2 See Host Prompt 2 Default None
83. he TekTerm Server starts or is reset Values 0 to 999 Default 25 4 12 TekTerm Server Software User Manual Field Description Maximum of The number of times the TekTerm Server attempts to connect to a host if the host Auto telnet Retries does not respond If this parameter is zero the TekTerm Server attempts to connect forever Values 0 to 999 Default 1 Allow TCP Sessions When selected sessions requested by the mobile device can be either auto login or TCP sessions At the prompt of a TCP session the operator can specify the desired host to connect to and provide username and password When not selected and Auto telnet login Enable is selected all sessions requested by the mobile device to this host emulation are Auto Login sessions On the mobile device CTRL A requests a new session CTRL B changes to the next available session and CTRL E changes to the last available session Default Selected ANSI Function Key and Arrow Key Mappings Options Screen Function Keys Each of the function key text boxes contains a code that is sent to the host when the corresponding function key is pressed on the mobile device Each code sequence is terminated by a NULL NULLs are not transmitted by the TekTerm Server Arrow Keys Each of the arrow key text boxes contains a code that is sent to the host when the corresponding arrow key is pressed on the mobile device Arrow key remapping also exists on the mobile devices but is
84. he host Remapping e Values None Blink Bold Reverse Default None Alarm When selected mobile devices beep when the word ALARM appears on the application screen in the location specified by the Command Region setting The word ALARM should be a display only field Command Region must also be set Default Not selected Clear When selected the TekTerm Server creates an empty entry field for an entry field that is filled with spaces Default Not selected Passthru When selected the TekTerm Server allows the host to send data directly to the serial port of the mobile device This is commonly used for printing Preparing Host Screens for Pass Through On the screen to be sent through the mobile device serial port the word PASSTHRU has to appear on the first line starting in the second column The actual data to be sent to the mobile device may start anywhere below the first line Attributes occupy a position in the screen buffer An attribute placed between column 2 and the end ofthe word PASSTHRU pushes all following characters one position to the right Therefore any required attributes should occupy column 1 of the first line just preceding the word PASSTHRU For example 2 3 PASST PA column 1 line 1 line 2 where is an attribute When the TekTerm Server finishes sending the data to the printer attached to the mobile device it sends a packet containing only a Record Separator Ox1e character to
85. hen enabled the timeout is applied Values 0 to 255 Default 12 It is recommended that this parameter be left at its default value For more information see Page Saving on page 4 6 Threshold When Page Saving is selected this is the minimum number of bytes that must be received from the host before the TekTerm Server treats the data as a new saved page Values 0 to 999 Default 200 For more information see Page Saving on page 4 6 Echo When selected smart echo is enabled Smart echo reduces the amount of data sent to the mobile device by decreasing the number of radio transmissions When smart echo is not enabled for a character mode application each keystroke is sent to the host in one transmission and the character is echoed by the host in another transmission When smart echo is enabled the TekTerm Server does not send the host echo to the mobile devices if it matches the data sent from the mobile device Thus the number of radio transmissions is reduced This mode also reduces or eliminates the delay between typing a character on the keyboard and displaying the character echoed by the host The maximum number of characters waiting for echo is 25 Any additional characters are sent to the host but not displayed Smart echo must also be enabled on the mobile device Default Selected 4 6 TekTerm Server Software User Manual Field Description Function Key When selected the TekTerm Server remaps the function
86. initiated by the host When set to 0 zero this option is disabled Values 0 to 32767 Default O TCP Session Request Decimal value received from a mobile device to request a new session You must Key ensure that this is the same value as that set on the mobile device Values 0 to 255 Default 1 ANSI Telnet Host Configuration 4 9 Field Description Session Cycle Key Decimal value received from a mobile device to cycle through sessions You must ensure that this is the same value as that set on the mobile device Values 0 to 255 Default 2 Last Active Session Decimal value received from a mobile device to return to the previous session Key You must ensure that this is the same value as that set on the mobile device Values 0 to 255 Default 5 Auto telnet login This list box enables the user to disable or enable automatic connection of Telnet Enable sessions from mobile devices to this host When auto Telnet is disabled Telnet sessions from the mobile devices to the host must be initiated manually from the mobile devices When auto Telnet is enabled the TekTerm Server initiates one Telnet session from each mobile device whose terminal number is mapped to this host Additional Telnet sessions may be initiated from each mobile device to the host but they must be initiated manually Auto Telnet sessions are only initiated for mobile devices which are online that is turned on and operating properly on the RF network
87. ion is automatically selected by the Auto te net Enable Host parameter When disabled Telnet sessions from the mobile devices must be manually initiated Values DISABLE AUTO TELNET Default DISABLE 2392 Telnet Host Configuration 7 13 Field Description Auto telnet Host The name or the IP address of the host to which auto Telnet reguests are directed Any host name which can be used at the TCP gt prompt on the mobile device may be used here Default None Note The host name must be resolvable by the TekTerm Server The TekTerm Server must be able to obtain an IP address for it For example the host name may correspond to an entry in the TekTerm Server host table or the TekTerm Server may be able to query a domain name server Auto telnet Without When selected the TekTerm Server attempts to connect to the host as soon as a User Action mobile device initializes and it attempts to reconnect ifthe Telnet session closes Default Selected General Host Options Screen Telnet Protocol Options Screen RF Modem Telnet Host Configuration 8 3 General Host Options Screen Field Description Name The unigue name ofthe host Default Unnamed Host Enabled When selected the host task is started when the TekTerm Server starts Emulation and protocol Emulation and protocol combination for this host Select MODEM Telnet Terminal range Terminal number range that communicates with this host Range 1 to 3840 For S900L r
88. is host Range 1 to 3840 For S900L range is 1 to 50 Default 1 to 32 For information on selecting the terminal range see Chapter 19 Setting Terminal Numbers on the General Host Options Screen Auto terminal number When selected TekTerm Server assigns terminal numbers to all mobile devices assignment not that use this session supported by Direct TCP When not selected terminal numbers must be assigned on the mobile devices Default Selected 7 4 TekTerm Server Software User Manual 2392 Emulation Options Screen 2392 Options Field Description Send CR with FKEY When selected a Carriage Return is sent after each function key Default Not selected Display Timeout Time in mSec that the TekTerm Server waits for more data from the host Screen data from a 2392 host can be divided into chunks If no more data is received by the TekTerm Server before this time has elapsed the TekTerm Server forwards the screen data received so far to the mobile device Values 50 to 5000 Default 300 TESS Options Field Description Alarm When selected mobile devices beep when the word ALARM appears on the application screen in the location specified by the Command Region setting The word ALARM should be a display only field Command Region must also be set Default Not selected Clear When selected the TekTerm Server creates an empty entry field for an entry field that is filled with spaces Default Not selected
89. keys for this host Remapping connection as defined in the ANSI Function Key and Arrow Key Mappings Options Screen Default Not selected For information on function key remapping see Function Keys on page 4 12 Arrow Key Remapping When selected the TekTerm Server remaps the arrow keys for this host connection as defined in the ANSI Function Key and Arrow Key Mappings Options Screen Default Not selected For information on arrow key remapping see Arrow Keys on page 4 12 Page Saving When selected the TekTerm Server uses page saving reducing data transmitted to the mobile devices The TekTerm Server maintains an image of each page stored on the mobile device After receiving an application screen the TekTerm Server tries to match the screen with a stored page If the page is already in the mobile device the TekTerm Server instructs the mobile device to redisplay its stored copy of the page minimal data is sent across the radio link for that page If the TekTerm Server finds no match for the page the complete page is sent to the mobile device If a page is close enough to a saved one close enough being defined by the Threshold setting then only the redisplayed and the changed data are sent resulting in reduced data transmission When page saving is enabled the number of saved pages is that which is set on the mobile device Refer to the appropriate user manual for details Default Selected Page Saving consider When se
90. l Options Screen Configure RRM Group Screen 13 3 General OptionsParameters 13 3 Polling Protocol Parameters 13 3 RadioParameters 13 5 GroupParameters 13 5 RRMs Screen Configure RRM Screen 13 6 Analyze Screen Analyze RRM Group Screen 13 6 GeneralParameters 13 6 Polling Protocol Parameters 13 6 RadioParameters 13 7 GroupParameters 13 7 RRESUNIS lt 2 AA a ete See AAA De AE AAA 13 7 RRM Groups Configuration 13 3 Overview The remote radio module RRM controls narrow band systems that require timeplexing In such systems the TekTerm Server controls the poll timing of the radio links on the bases The RRMs in each group transmit in turn on the same frequency The TekTerm Server coordinates the trans missions so that no RRMs transmit at the same time This differs from base stations where the timing of the radio transmissions is controlled only by the base stations themselves RRM groups and RRMs use narrow band FM radios The performance of such groups depends critically on the interaction between the radio parameters Psion provides a parameter analysis utility to help you to set up the groups
91. ld 3274 emulation Default Not selected Treat EraseWrite When selected during PASSTHRU printing of multiple screens buffered print data NOP as Write NOP is not erased Default Selected Terminal Protocol The protocol used for the connection between the mobile devices and the TekTerm Server Options are TESS BCM This uses the TekTerm Server data caching and page saving features HTML HTTP This uses the Communication Server HTTP server The browser on the mobile devices must connect to port 80 on the TekTerm Server Default TESS BCM 3274 Telnet Host Configuration 2 5 TESS Options Field Description Alarm When selected mobile devices beep when the word ALARM appears on the application screen in the location specified by the Command Region setting The word ALARM should be a display only field Command Region must also be set Default Not selected For more information see Command Region on page 2 11 Clear When selected the TekTerm Server creates an empty entry field for an entry field that is filled with spaces Default Not selected Passthru When selected the TekTerm Server allows the host to send data directly to the serial port of the mobile device This is commonly used for printing Preparing Host Screens for Pass Through On the screen to be sent through the mobile device serial port the word PASSTHRU has to appear on the first line starting in the second column The actual data to be sent to the mobil
92. ld occupy column 1 of the first line just preceding the word PASSTHRU For example column line 1 line 2 where is an attribute When the TekTerm Server finishes sending the data to the printer attached to the mobile device it sends a packet containing only a Record Separator 0x1e character to the host The host must wait for this packet before sending any more screens including other PASSTHRU screens to the mobile device Refer to the user manual for the mobile device for information about setting parameters on the mobile device for pass through Default Not selected Enable TekTerm When selected the TekTerm Server uses TekTerm Screen Formatter TekTerm Screen Formatter Screen Formatter was previously known as TSF 0 Default Not selected Remote Print When enabled the TekTerm Server sends the print page to a mobile device whenever the mobile device requests it by sending the F17 function key from the mobile device or the PRINT key on older mobile devices The TekTerm Server sends the function response back to the host Support for printing must be enabled on the mobile device refer to the appropriate user manual for the mobile device for more information Default Not selected 7 6 TekTerm Server Software User Manual Field Description Host Print When selected an application can send data to the display on the mobile device as well as to its attached printer The text that is passed to the prin
93. lds with this mode set are filled The transmission is sent by a Function O FO code 8 Allow overwriting of previously entered data 16 Start the search for a matching AIAG field at the current cursor position Otherwise the cursor starts at the top of the page For example the symbol is used to apply the cursor matching function since adding 16 to 48 results in decimal value 64 which is the ASCII value for the character Match Characters Match Use Character Match a number amp Match a letter either case A Match an upper case letter Match a lower case letter Match an alphanumeric character j Match a letter number or space Match a punctuation character E Match any character Match all character positions in the field with the preceding character Match any remaining characters but not necessarily the remainder of the field with the preceding character 5250 Telnet Host Configuration 3 13 HTML HTTP Options Field Description Enable Colour Support When selected when an application fills a field with spaces an empty entry field is displayed Default Not selected Foreground Colour This is the foreground colour for the text that the TekTerm Server HTTP server sends to mobile devices connecting via HTTP The choices are the 16 predefined HTML colour names Values Aqua Black Blue Fuchsia Gray Green Lime Maroon Navy Olive Purple Red Silver Teal White Yellow Default Black
94. lected a double byte character half is replaced with a space preventing Double Byte problems with mobile device screen displays Characters f ji While using double byte character sets for example Chinese or Korean the page saving function can cause a double byte character to be partially overwritten This can cause unprintable screen data and unintended characters and may cause the mobile device to shift data on the screen Select this checkbox only when using double byte character sets Default Not selected RLE When selected the TekTerm Server uses run length encoding RLE on the data it sends across the radio link RLE compresses repeated characters going from the host to the mobile device If repeated characters are found in the data stream the first one is sent followed by a short escape sequence 3 or 4 characters which tells the mobile device how many times to repeat this character In this way RLE compresses the data and decreases the total amount of radio link traffic Default Not selected ANSI Telnet Host Configuration 4 7 Field Description Convert 7 to 8 Bits When selected the TekTerm Server converts 7 bit control sequences to their 8 bit equivalents in ANSI data streams going to the mobile devices This replaces 7 bit two character escape sequences with a single equivalent 8 bit character compressing the data For example the escape sequence ESC is converted to CSI Default Not selected Lower
95. led if Page Saving is enabled Escape Timeout is ignored and dangling escapes are carried over to the next screen When enabled if Page Saving is not enabled Escape Timeout applies Terminal to Host When enabled the timeout is applied Values 0 to 255 Default 12 It is recommended that this parameter be left at its default value For more information see Page Saving on page 5 6 Threshold When Page Saving is selected this is the minimum number of bytes that must be received from the host before the TekTerm Server treats the data as a new saved page Values 0 to 999 Default 200 For more information see Page Saving on page 5 6 Echo When selected smart echo is enabled Smart echo reduces the amount of data sent to the mobile device by decreasing the number of radio transmissions When smart echo is not enabled for a character mode application each keystroke is sent to the host in one transmission and the character is echoed by the host in another transmission When smart echo is enabled the TekTerm Server does not send the host echo to the mobile devices if it matches the data sent from the mobile device Thus the number of radio transmissions is reduced This mode also reduces or eliminates the delay between typing a character on the keyboard and displaying the character echoed by the host The maximum number of characters waiting for echo is 25 Any additional characters are sent to the host but not displayed
96. licking Export displays the Export Configuration Database screen Specify the name of the backup file and then click Export Configuration Import Database From a File Clicking Import displays the Import Configuration Database From File screen Specify the name and the path of the backup file to be imported AN IMPORTANT The newly imported configuration must be validated and committed before it can become the active configuration Restart TekTerm Server Click Restart to restart the TekTerm Server Validate and Save Current Configuration Clicking Validate displays the Validate and Save Configuration screen Validate Configuration When Validate Configuration is clicked the TekTerm Server checks the configuration database cache for errors then displays the Database Validation Results screen which lists configuration errors If Update PComm is selected when Validate Configuration is clicked the existing device definitions are erased and re created from scratch using the current configuration settings for all SNA hosts This allows changes to the terminal range and LU name of the SNA host configurations to be implemented Validate and Commit When Validate and Commit is clicked the validate operation is immediately followed by a commit there is no option to undo INTTOUCIION lt a 0 AA E ee a ie Ree ie 19 3 Systems with One Host 2 iaae eaa ana a A a 19 3 Systems with Multiple Hosts 19
97. ling Protocol Parameters This section lists the settings for the polling protocol parameters Field Description Number of Poll Windows The setting of Number of Poll Windows on page 13 4 Size of Poll Windows The setting of Size of Poll Windows on page 13 4 Maximum Message The setting of Maximum Message Segment Size on page 13 4 Segment Size Free Window Factor The setting of Free Window Factor on page 13 4 Message Mode Limit The setting of Message Mode Limit on page 13 4 RRM Groups Configuration 13 7 Radio Parameters This section lists the settings for the radios in the RRM group Sync Delay Displays the setting of Sync Delay on page 13 5 Remote Txon Displays the setting of Sync Delay on page 13 5 Baud Rate The baud rate for the radios in this RRM group Two level modulation supports baud rates of 4800 and 9600 bits per second Four level modulation supports bit rates of 9600 and 19 200 bits per second The analyzer constrains the available baud rates to those supported by the selected modulation Values 4800 9600 19200 Default 9600 Modulation The type of narrow band FM modulation used by the radios in this RRM group All radios in the group must use the same modulation Available modulations are two level and four level Not all radios support all modulations in particular older radios only support the two level modulation Values 2 level 4 level Default 2 level RRM Radios Displays the type of radio
98. link 14 3 A ee ea 13 6 SNMP 322208 2 tia AS 17 3 TCP IP base station 12 4 TES 2 5 3 5 7 4 9 5 P Pages 2 6 3 6 7 7 9 5 Page Saving 4 6 5 6 Page Saving consider Double Byte Characters 4 6 5 6 Pai ui IA 2 5 3 5 7 5 9 5 Percent Polling Protocol Terminal Timeout 14 4 nii pl Sense ne 14 3 polling protocol RRM groups 2222222eeeeenn 13 3 13 6 Polling Protocol Terminal Timeout 14 3 Poll Interval S 16 4 Poll Timeout S 16 4 Poll Timeout in Terminals average load 13 8 Poll Timeout in Terminals maximum load 13 8 Poll TCS degt cond ine meine bettie E 16 4 Preferred Primary 16 4 Print Form Length 2 10 3 10 7 9 Print Line 2 10 3 10 7 9 Procedures 2 5 3 6 7 4 PFOLOCOI IA A a 12 3 protocol options 2393 Telnet 7 12 WA as ee na 6 4 protocols supported xii Proxy throttling for non IP terminals 17 3 R radio link OPptions 14 3 Radio Link Protocol 13 6 radio options RRM groups 13 7 radio settings RRM group
99. lt IBM 2378 2 Host Port The port number on the host for this connection Values 1 to 32767 Default 23 2 14 TekTerm Server Software User Manual Field Description Maximum Sessions The maximum number of Telnet connections that can originate from per Terminal each mobile device Values 1 to 127 Default 4 First Local Terminal The port number from which the TekTerm Server makes a Telnet connection for the Port first terminal Additional Telnet sessions are assigned higher port numbers Values 1 to 32767 Default 10000 Local IP Address to The IP address of the TekTerm Server interface that connects to this host It is used Bind with the local port numbers to create a unique socket for each mobile device session Default 0 0 0 0 First Terminal Listen The lowest port number on which the TekTerm Server listens for Telnet connections Port initiated by the host When set to 0 zero this option is disabled Values 0 to 32767 Default O Actively Negotiate When selected the TekTerm Server performs advanced negotiations with the host with Host during Telnet connection Default Not selected Configure LU names When selected the TekTerm Server requests LU names when initiating the Telnet connection with this 3274 host Terminal names can be configured on the 3274 Terminal Naming screen Default Not selected For more information see 3274 Telnet Terminal Naming Screen on page 2 15 LU Name Prefix The LU prefix to be add
100. mal character code for one of the first 127 ASCII characters For example assume that the gt character ASCII decimal character code 62 is defined for visible match fields This character must immediately precede the entry field Part gt The field Part gt includes the character gt and is followed by the part number entry field on the screen If any other character was chosen as the last character of the text the entry field would not be a match field The preloaded data sent to a mobile device may consist of the exact characters special match characters or a combination of the two For example suppose you wish to preload an entry field with a part number If the exact part number is known you may preload the field with that part number If more flexibility is required and part numbers always begin with two alphabetic characters followed by a hyphen character and four digits then the match string for the field could be HHHH If an entry is different from the preloaded data the entry is displayed the mobile device beeps and the cursor is in the first position of the match field Now either another entry in the match field can be made or the cursor can be moved to a new field When an entry even if it does not match the host preloaded data is made in a match field this entry is sent to the host as part of the modified data from the mobile device during the next transmission A value of O zero disables this ma
101. n When page saving is enabled the number of saved pages is that which is set on the mobile device Refer to the appropriate user manual for details Default Selected Page Saving consider When selected a double byte character half is replaced with a space preventing Double Byte problems with mobile device screen displays Characters ji r j While using double byte character sets for example Chinese or Korean the page saving function can cause a double byte character to be partially overwritten This can cause unprintable screen data and unintended characters and may cause the mobile device to shift data on the screen Select this checkbox only when using double byte character sets Default Not selected RLE When selected the TekTerm Server uses run length encoding RLE on the data it sends across the radio link RLE compresses repeated characters going from the host to the mobile device If repeated characters are found in the data stream the first one is sent followed by a short escape sequence 3 or 4 characters which tells the mobile device how many times to repeat this character In this way RLE compresses the data and decreases the total amount of radio link traffic Default Not selected Convert 7 to 8 Bits When selected the TekTerm Server converts 7 bit control sequences to their 8 bit equivalents in ANSI data streams going to the mobile devices This replaces 7 bit two character escape sequences with a single
102. n Cellular Mode must be selected e Optionally an Automatic Radio Address assignment range can be set Automatic Terminal Number Assignment must be implemented For details see Chapter 14 Radio Link Features Configuration Mobile Device Narrow Band Configuration for Remote Sockets There are no parameters specific to remote sockets on the mobile device The narrow band radio must be configured to communicate with the base station For information on configuring narrow band radios see Narrow Band Polling Protocol Parameter Settings on IngenuityWorking Base Station Narrow Band Configuration for Remote Sockets There are no parameters specific to remote sockets on the base stations however the base stations or RRMs require configuration Overview General Options Screen Connectivity Options TCP IP Options for Base StationScreen Base Station Configuration 12 3 Overview The parameters in this section control access points and narrow band base stations General Options Screen Field Description Name The name for the base station Values Any text string Default Unnamed Base Station Protocol The protocol to be used for the connection to this base station Values TCP IP Default TCP IP First Terminal The TekTerm Server terminal number that is mapped to the Psion device with Terminal ID 1 that communicates with this base station Values 1 to 3840 For
103. n and the client application You have two options for this plugin Use a standard plugin downloaded from Ingenuity Working e Write a custom plugin Sample code for plugins downloads as part of NDP For details see the NDP Narrow Band Data Proxy Developers Guide You must copy the NDP plugin onto the TekTerm Server as well as any other files that the plugin requires 10 4 TekTerm Server Software User Manual General Host Options Screen Field Description Name The unique name of the host Default Unnamed Host Enabled When selected the host task is started when the TekTerm Server starts Emulation and Emulation and protocol combination for this host protocol Select Narrowband Data Proxy Terminal range Terminal number range that communicates with this host Range 1 to 3840 For S900L range is 1 to 50 Default 1 to 32 For information on selecting the terminal range see Chapter 19 Setting Terminal Numbers on the General Host Options Screen Auto terminal When selected TekTerm Server assigns terminal numbers to all mobile devices that number assignment use this session not supported by ji j Direct TCP When not selected terminal numbers must be assigned on the mobile devices Default Selected E NOTE Itis recommended that Auto terminal number assignment is selected Narrowband Data Proxy Emulation Options Screen Field Description Host Library Path This is the path on the TekTerm Server
104. n sends commands to the TekTerm Server which acts as a socket proxy and creates a TCP socket connection to the host The host application manages the data connection e Fora Windows CE NET 4 2 mobile device use version 2 02 of the Mobile Devices SDK e Fora Windows CE 5 0 mobile device use the latest version of the Mobile Devices SDK 11 4 TekTerm Server Software User Manual General Host Options Screen ap NOTE Use of overlapping terminal ranges is not recommended for the Remote Sockets emulation Field Description Name The unique name of the host Default Unnamed Host Enabled When selected the host task is started when the TekTerm Server starts Emulation and Emulation and protocol combination for this host protocol Select Remote Socket Emulation Terminal range Terminal number range that communicates with this host Range 1 to 3840 For S900L range is 1 to 50 Default 1 to 32 For information on selecting the terminal range see Chapter 19 Setting Terminal Numbers on the General Host Options Screen Auto terminal When selected TekTerm Server assigns terminal numbers to all mobile devices that number assignment use this session not supported by ji ji Direct TCP When not selected terminal numbers must be assigned on the mobile devices Default Selected Other TekTerm Server Settings Associated with Remote Sockets The following must also be configured on the Radio Link Features screen e Operate i
105. nd column of line 13 on the 24 x 80 screen PRINT should be defined as display only text The print page is positioned below the display page ofthe mobile device see the following diagram The size of the print page is always the same as the display page of the mobile device assuming that in the mobile device configuration the page length is less than 12 lines When Host Print is enabled the TekTerm Server passes the print page to the mobile device after receiving the application screen from the host Display page 8 x 40 zl Ch LD WD Fa 8 Print Page 8 x 40 Unlike with the Passthru option when using Host Print no escape commands can be sent to the printer Support for printing must be enabled on the mobile device refer to the appropriate user manual for the mobile device for more information Default Not selected 3 8 TekTerm Server Software User Manual Field Description Transmit Line When enabled all modified data on the mobile device is automatically transmitted when the operator enters data into an entry field on or above this line The value in this text box specifies the line on the screen which is designated as the transmit line The last entry field on or above the transmit line on the screen is identified as the field which will cause all modified data to be sent to the host Any entry fields that exist on lines below the transmit line will not cause the screen to be transmitted A value of 0 zero
106. ng can be enabled and operate independently of each other Arrow key sequences sent from the mobile device can be switched between Application mode and Cursor Key mode by the DECCKM command sent by the host The sequences are CSI 1h and CSI 11 TekTerm Client on the mobile device has a DEC Cursor Keys setting in the Keyboard Modes menu where the mode can be selected The default arrow key sequences in Psion ANSI debug format are In Cursor Key Mode 7 Bit 8 Bit Up arrow 1b A 9b A Down arrow 1b B 9b B Right arrow 1b C 9b C Left arrow 1b D 9b D ANSI SSH Host Configuration 5 13 In Application Mode 7 Bit 8 Bit Left arrow 1b OA SHA Right arrow 1b OB 8f B Up arrow 1b OC 8f C Down arrow 1b OD 8f D These sequences are remapped by the TekTerm Server to 4 configurable sequences each a minimum of 5 hexadecimal characters long A null entry terminates the map to sequence it is not necessary to transmit nulls The default values for arrow key mappings are the 7 bit Cursor key Mode values The TekTerm Server recog nizes both the 7 bit and the 8 bit forms of the key sequences The same escape timeout applies to arrow key remapping as to function key remapping The cursor key mode setting in the mobile device is ignored by the TekTerm Server If the host changes the key sequence using DECCKM the TekTerm Server continues to remap the new key sequences With arrow key mapping enabled DECCKM has no net eff
107. nitors messages and polls from this connection Hosts usually send messages or null polls to the TekTerm Server with a period of approximately 40 seconds If the TekTerm Server does not receive a message or poll within 40 seconds it closes the connection Default Not selected Note For older Unix handlers hosts this parameter should be deselected In all other cases this parameter should be selected OVERVIEW oo ee a YA 7 3 GeneralHostOptions 7 3 2392 EmulationOptionsScreen 7 4 2392 OOUONS EE 7 4 TESS OPUONS a eer wa ES Oe De A A ee RRS ee ae A 7 4 2392 Telnet Protocol Options Screen 2 2 CL nn 7 12 2392 Telnet Host Configuration 7 3 Overview The TekTerm Server can emulate HP2392A display terminals asynchronous terminals capable of character line and block mode These terminals also handle ANSI terminal commands Data compression And Caching Software Terminal Software Host Application Emulation Software Base Terminal Station or Communications Server Access Point Host Computer General Host Options Field Description Name The unique name of the host Default Unnamed Host Enabled When selected the host task is started when the TekTerm Server starts Emulation and protocol Emulation and protocol combination for this host Select 2392 Telnet Terminal range Terminal number range that communicates with th
108. niwie 4 4 ANSI Emulation Options Green 4 4 ANSI Telnet Protocol Options Gcreen tnnt En 4 8 ANSI Function Key and Arrow Key Mappings Options Screen ccccccceceeeeeeeeeeeeeeeeeeeeteeeeeeeees 4 12 ele A ANON E O Naaa AO SESER ER e 4 13 Chapter 5 ANSI SSH Host Configuration EE 5 3 General Host Options aan ae ek 5 4 ANSI Emulation Options Green 5 4 ANSI SSH Protocol Options Screen nenn ennnnnnnnennnennnennnenn nn 5 7 ANSI Function Key and Arrow Key Mappings Options Screen essen 5 12 Chapter 6 9010 Telnet Host Configuration General Host Options weighs as 6 3 9010 Emulation Options seeseeeeeeeeeeeee nener nesr tsrtrsttesrnenttetater ttt nat erate AAEE AEEEAEEEEEEEE EEEE EEEEEEEE EEEE EEEE EEEE EEE 6 3 9010 Protocol Options Gcreen nn nne nenn sneannnnnen 6 4 Chapter 7 2392 Telnet Host Configuration OVEIViEWei ne da ah ee ee 7 3 General Host Options a a ss iaaa 7 3 2392 Emulation Options Green 7 4 SEENEN 7 4 TESS OS aa ambaa ai kaki kakaa mbaaali 7 4 2392 Telnet Protocol Options Screen wwww www ww www wwa awana naww wakana nuna kunakuwa kwakua kukana kukimu eran enanas 7 12 Table of Contents vii Chapter 8 RF Modem Telnet Host Configuration General Host Options Gcreen wawa ww wa www wwa wwa wwa wwa kawawa kwaka wakaka wekwa kukiwa wa kamaa 8 3 Telnet Protocol Options Screen ccc seeeseeeeeceeeeeeeeaaeeaaeeaaeeaaeeaaeaaeeaaeeaaeeaeceaeeeaaecaeceaeeaaeeeeeeaeeeeeess 8 3
109. nnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnennnnnninninnn 13 3 Polling Protocol Parameters sua se ee 13 3 eege Eee 13 5 CNS 13 5 RRMs Screen Configure RRM Screen u enaen een 13 6 Analyze Screen Analyze RRM Group Screen swwmmmsamimananminanemmaaazimimanazimananimanzemi anazimia 13 6 General Paa an ee ee 13 6 Polling Protocol EE Aa aa ali civil 13 6 Radio Gu 13 7 Group Parameters AA 13 7 SE EISE EE 13 7 vili TekTerm Server Software User Manual Chapter 14 Radio Link Features Configuration Cellular Switching and TimepleKing w w wwwwamamanamwwwwananaaamu mumu ee east 14 3 Radio Link Features Screen AI awaka 14 3 General Options cuina as 14 3 Chapter 15 802 IQ v1 and v2 Features Configuration 802 1O Ce e Lei lila 15 3 902 10 Configuration Screen E 15 3 802 1Q Common Features aaa 15 3 Available Interfaces wwwwwwwawwawwamwwa mwanama nee nsennnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnsnnns nenne 15 4 802 1Q v2 Features aa dap ireira ai akauawa kaika shakani 15 4 Chapter 16 Redundancy Configuration LA WA AA AA AA AAA WA WAW AAA 16 3 Redundancy Parameters SO Nini ads 16 4 General le ee 16 4 Available IMA EE 16 4 Chapter 17 System Configuration TA E 17 3 SNMP Parameters Screen nr rr nnnrnnnannnn 17 3 Miscellaneous Options Green 17 4 Chapter 18 Miscellaneous Commands Configuration Display Entire Database Contents Database Validation Results Gcreen 1
110. nt in bytes that will be sent over the Segment Size Psion radio network Larger messages are broken into parts Values 32 to 116 Default 100 Number of Retries The number of times the RRM retransmits a message to a terminal after receiving no acknowledgement from the terminal before it declares the terminal offline Values 1 to 7 Default 3 Collision Size The smallest number of characters of noise received by the RRM that will be interpreted as interfering transmissions from other Psion equipment When this threshold is exceeded the RRM starts collision resolution Values 3 to 10 Default 6 Free Window Factor The probability that the RRM will include a free window in its poll during which any terminal may transmit Values 0 to 7 Default O Message Mode Limit The probability of including a message mode poll in its poll transmission Values 0 to 7 Default 4 Callsign Period The amount of time between transmissions of the call sign This parameter is in minutes A value of 0 zero indicates that no call sign is transmitted Values 0 to 60 Default O Callsign String The text to be transmitted as the call sign of the RRM The text is transmitted as or Morse code Callsign Text Default Teklogix RRM Groups Configuration 13 5 Radio Parameters This group of parameters sets radio parameters on the devices that make up the RRM group These are parameters that should be set to the same values on all the mobil
111. ode is accepted The format of the preloaded data is lt mode gt lt AlAG prefix gt The application program distinguishes an entry field as AIAG by preceding the entry field with this special AIAG character A value of 0 zero disables this feature Values 0 to 255 Default 0 For the AIAG mode character table see AIAG Mode Values on page 7 11 7 8 TekTerm Server Software User Manual Field Description Visible Match The decimal value of the special character ASCII used to tag a field to use Character visible match mode With field matching the host computer preloads data into an entry field Now the mobile device operator can make an entry that matches this preloaded data For visible match fields the preloaded data is displayed in the entry field on the mobile device The application program distinguishes an entry field as a match field by preceding it with a special character The special character is entered as the decimal character code for one of the first 127 ASCII characters For example assume that the gt character ASCII decimal character code 62 is defined for visible match fields This character must immediately precede the entry field Part gt The field Part gt includes the character gt and is followed by the part number entry field on the screen If any other character was chosen as the last character of the text the entry field would not be a match field The preloaded data sent to a mobil
112. ogin When enabled the host connection is automatically selected by the Auto te net Enable Host parameter When disabled Telnet sessions from the mobile devices must be manually initiated Values DISABLE AUTO TELNET Default DISABLE Auto telnet Host The name or the IP address of the host to which auto Telnet requests are directed Any host name which can be used at the TCP gt prompt on the mobile device may be used here Default None Note The host name must be resolvable by the TekTerm Server The TekTerm Server must be able to obtain an IP address for it For example the host name may correspond to an entry in the TekTerm Server host table or the TekTerm Server may be able to query a domain name server Auto telnet Without When selected the TekTerm Server attempts to connect to the host as soon as a User Action mobile device initializes and it attempts to reconnect if the Telnet session closes Default Selected Custom Device Names Click Configure to open the 5250 Telnet Terminal Naming Screen For more information see 5250 Telnet Terminal Naming Screen on page 3 17 Device Name Prefix A prefix for the TekTerm Server generated virtual device name The device name sent to the host starts with the prefix followed by the terminal number which may be followed by a session letter For example if the virtual device name prefix is PTX the first session on terminal number 2 receives a virtual device name of PTX0002A Fo
113. or this host Select ANSI SSH Terminal range Terminal number range that communicates with this host Range 1 to 3840 For S900L range is 1 to 50 Default 1 to 32 For information on selecting the terminal range see Chapter 19 Setting Terminal Numbers on the General Host Options Screen Auto terminal number When selected TekTerm Server assigns terminal numbers to all mobile devices assignment not that use this session supported by Direct f ji E TCP When not selected terminal numbers must be assigned on the mobile devices Default Selected ANSI Emulation Options Screen Field Description Maximum Screen Size The maximum dimensions of the mobile device screen These screen rows x columns dimensions are used to reserve memory for screen caching when page saving is enabled Rows 4 to 60 Columns 10 to 132 Default 24 x 80 Host Timeout When Page Saving is enabled the host timeout in 60ths of a second Values 0 255 Default 15 For more information see Page Saving on page 5 6 Field Description ANSI SSH Host Configuration 5 5 Escape Timeout The escape timeout in 60ths of a second This is the length of time that the TekTerm Server holds an ESC while waiting for another character If another character is received within this time the pair of characters are treated as an escape sequence If another character is not received within this time the ESC is sent on to its destination Host to Terminal When enab
114. os 13 7 S save configuration 18 3 Screen Size row X COl 9 4 Send CR with FKEY 7 4 Send IAC Break as a Attention Key 2 14 Send IAC Interrupt Process as a System Request 2 14 Serial ll III aaa 2 10 3 10 7 9 Serial Number 17 4 server settings remote sockets 11 4 Session Cycle Key 4 9 Size of Poll Windows 13 4 13 6 SNMP settings WWW 17 3 software TT EE xiv SSH protocol options A AA AAA 5 7 starting TekTerm Server 1 3 Start Page ubicada iy eens 9 4 stopping TekTerm Server 1 3 supported emulations xii ProloColS EE xii Sync Del 13 5 13 7 system configuration username and password 17 3 T TCP Session Request Key 4 8 TekTerm Server SIPG ceee eee eee 1 3 TekTerm Serverr Sa ES Laa Ua AA eee ee 1 3 Telnet protocol options 8 3 IA EE 2 13 A alee be twbhodes etal adore Sieseees 3 14 ANS livin e dada de 4 8 Telnet terminal naming A AE Pha de be 2 15 3274 buttons 2 16 BI EIA WA 3 17 5250 buttons 3 17 Terminal Initialization Data 4 7 5 7 Terminal name 3 17
115. r this setting to be active Enable Telnet Enhancements must be selected The prefix can include uppercase letters A to Z numbers 0 to 9 and the special characters and Lower case letters are accepted and translated to uppercase characters The prefix must not begin with a number Values 1 to 5 characters Default None 3 16 TekTerm Server Software User Manual Field Description Enable Telnet When selected the TekTerm Server reguests a specific virtual device name from Enhancements the host for each mobile device session Or When not selected the host assigns a device name to each session Enable Virtual Device Virtual device names are configured through the 5250 Telnet Terminal Naming Names Screen or using the Device Name Prefix When this feature is selected the following sequence is used to assign virtual device names 1 If a full device name has been specified for a terminal using the 5250 Telnet Terminal Naming Screen that name is assigned 2 Ifthe Device Name Prefix is configured this prefix is used to generate a device name for the terminal 3 The host assigns a device name Device names can be either fixed or flexible Flexible device names are created when the maximum number of sessions is configured to be greater than 1 one In this case each device name has a maximum length of 10 characters This consists of a maximum of 9 fixed characters with an incrementing session letter appended to them If the r
116. range see Chapter 19 Setting Terminal Numbers on the General Host Options Screen Auto terminal number When selected TekTerm Server assigns terminal numbers to all mobile devices assignment not that use this session supported by Direct f ji ji TCP When not selected terminal numbers must be assigned on the mobile devices Default Selected ANSI Emulation Options Screen Field Description Maximum Screen Size The maximum dimensions of the mobile device screen These screen rows x columns dimensions are used to reserve memory for screen caching when page saving is enabled Rows 4 to 60 Columns 10 to 132 Default 24 x 80 Host Timeout When Page Saving is enabled the host timeout in 60ths of a second Values 0 255 Default 15 For more information see Page Saving on page 4 6 Field Description ANSI Telnet Host Configuration 4 5 Escape Timeout The escape timeout in 60ths of a second This is the length of time that the TekTerm Server holds an ESC while waiting for another character If another character is received within this time the pair of characters are treated as an escape sequence If another character is not received within this time the ESC is sent on to its destination Host to Terminal When enabled if Page Saving is enabled Escape Timeout is ignored and dangling escapes are carried over to the next screen When enabled if Page Saving is not enabled Escape Timeout applies Terminal to Host W
117. rm Server continues to remap the new key sequences With arrow key mapping enabled DECCKM has no net effect Host Configuration The host should be configured to work with ANSI VT 100 or ANSI VT 220 terminals OVERVIEW ee eee WA 5 3 GeneralHostOptions 5 4 ANSI EmulationOptionsScreen 5 4 ANSI SSH Protocol Options Screen a 5 7 ANSI Function Key and Arrow Key Mappings Options Screen 5 12 ANSI SSH Host Configuration 5 3 Overview The TekTerm Server manages the radio link caches data going to and from the mobile devices and super vises the hand off of devices as they move from one base to another SSH provides a secure shell for the ANSI connection Figure 5 1 Method 1 Data compression And Caching AA Terminal Software Host Application Base Terminal Station or Access Point Communications Server Host Computer Figure 5 2 Method 2 Data compression And Caching Software Terminal Software Host Application Base Terminal Station or Communications Server Access Point TSDK Software Host Computer 5 4 TekTerm Server Software User Manual General Host Options Field Description Name The unigue name ofthe host Default Unnamed Host Enabled When selected the host task is started when the TekTerm Server starts Emulation and protocol Emulation and protocol combination f
118. rm Servers communicate with an arbiter another node which serves as a reference on the network There can only be one secondary TekTerm Server Both TekTerm Servers must be connected to the network and each TekTerm Server is aware of the IP address of the other The secondary TekTerm Server polls the primary TekTerm Server and the primary TekTerm Server responds They exchange information about their status If the secondary TekTerm Server cannot communicate with the primary TekTerm Server but can communicate with the arbiter it assumes that the primary TekTerm Server is not working It becomes the primary TekTerm Server and it assumes control of the Psion system When the original primary TekTerm Server comes online again it assumes secondary status the second TekTerm Server continues as the primary If the TekTerm Servers cannot communicate with the arbiter they assume that the network is not working db NOTE When control of the system is passed from one TekTerm Server to the other TekTerm Server ses sions between hosts and terminals are closed and terminals and bases are reset Both TekTerm Servers must be configured identically with the exception of their own IP addresses and the Backup IP Address parameter the address of the other TekTerm Server A IMPORTANT The TCP Direct Connections for TekTerm parameter on the Radio Link Features screen must be enabled for redundancy to work See Radio Link Features Screen on page 14 3
119. s 13 5 redundancy general options 16 4 interfaces 16 4 OVEIVIEW ooo 16 3 Refrain from sending On line amp Off line messages 6 3 Remote Print 2 6 3 6 7 5 remote sockets base station settings 11 4 emulation xii general hostoptions 11 4 narrow band settings 11 4 OVEIVIEW ooo 11 3 server settings 11 4 Remote Tron 13 5 13 7 restart TekTerm Server 18 3 Return Pre Filled Data to Host 9 4 RF modem emulation xii general hostoptions 8 3 RUE EEN 4 6 5 6 RRM OPUONS tcc tae ne od Ae hota aie ced eles Ss Oh 13 6 RRM Combination Cycle 13 8 RRM groups analysisresults 13 7 ANALYZE ee a ide 13 6 general options 13 3 13 6 group Options 13 7 group settings 13 5 OVEIVIEW ooo 13 3 polling options 13 6 polling protocol settings 13 3 radio options 13 7 radio settings 13 5 RRMRadi
120. s 10 to 20 Can communicate with Host1 and Host2 Terminal 10 is mapped to Host2 session 1 Terminal 20 is mapped to Host2 session 11 When the terminals connect with the TekTerm Server they are given the choice of hosts with which to communicate For instance terminal 13 corresponds to session 13 on Host1 and to session 4 on Host and is given that choice of hosts Numerics 2392 emulation xii emulation options 7 4 general hostoptions 7 3 leide EE 7 4 Telnet protocol options 7 12 3274 emulation xii emulation options 2 4 function key mappings 2 16 general hostoptions 2 3 host configuration 2 17 HTML HTTP options 2 13 lee 2 4 Telnet protocol options 2 13 Telnet terminal naming 2 15 Telnet terminal naming buttons 2 16 3277 terminal xii 3278 2 E terminal xii 3278 2 terminal xii 5250 emulation xii emulation options 3 4 function key mappings 3 18 general hostoptions 3 3 host
121. s string is sent to the host Default None 4 8 TekTerm Server Software User Manual ANSI Telnet Protocol Options Screen Field Description Terminal Type The type of terminal to be emulated by the TekTerm Server Values VT100 VT220 Default VT100 Host Port The port number on the host for this connection Values 1 to 32767 Default 23 Maximum Sessions The maximum number of Telnet connections that can originate from per Terminal each mobile device Values 1 to 127 Default 4 Close Host sessions When selected all host sessions close when the mobile device resets on Terminal reset f ji li ji When not selected the sessions remain open if the mobile device resets Default Not selected First Local Terminal The port number from which the TekTerm Server makes a Telnet connection for Port the first terminal Additional Telnet sessions are assigned higher port numbers Values 1 to 32767 Default 10000 This parameter only takes effect if Local IP Address to Bind is specified Do not set the first local terminal port to 16100 Port 16100 is used as a listening port by hosts using the 9010 protocol Local IP Address to The IP address of the TekTerm Server interface that connects to this host It is Bind used with the local port numbers to create a unique socket for each mobile device session Default 0 0 0 0 First Terminal Listen The lowest port number on which the TekTerm Server listens for Telnet Port connections
122. sed during the key exchange portion of authentication to verify that the client is really talking to the correct server For this to be possible the TekTerm Server should have previous knowledge of the SSH host public key Field Description Automatically accept When selected the public key sent by the host when the connection is initiated new host key is not validated When not selected the public key received from the host when the connection is initiated is checked against the contents of Host Key Default Selected For more information see Host Key on page 5 10 Automatically accept When the public key is changed on the host the new public key is sent to the changed host key TekTerm Server When selected the new key is not validated When not selected the new public key is checked against the contents of Host Key Host Key must be entered manually Default Selected For more information see Host Key on page 5 10 Host Key The public key of the host This is entered only if Automatically accept new key and Automatically accept changed key are not selected Default None User Authentication Field Description Username saved so The username sent to the host when the host requests it The same username is users will not be provided for all mobile devices using this connection prompted Default None Note This field is not needed if Username Prompt not used if username is configured on page 5 9 is con
123. ssion supported by Direct i ji ji TCP When not selected terminal numbers must be assigned on the mobile devices Default Selected Emulation Options Screen 5250 Options Field Description Write Error Code Advisory text Error codes are sent to the mobile device as advisory text This is written at the bottom of the screen Default Screen text Error codes are sent to the mobile device as regular screen text Default Advisory text Use International When selected the TekTerm Server uses the international EBCDIC character set EBCDIC the positions of the and characters are swapped Default Not selected Allow null character in When selected empty fields show video attributes properly when using fixed fields 5250 emulation Default Selected Terminal Protocol The protocol used for the connection between the mobile devices and the TekTerm Server Options are TESS BCM This uses the TekTerm Server data caching and page saving features HTML HTTP This uses the Communication Server HTTP server The browser on the mobile devices must connect to port 80 on the TekTerm Server Default TESS BCM IBM3179 2 Default The default colour for the mobile device Color Green Default TekTermDefined The green attribute is remapped to the TESS Default attribute 5250 Telnet Host Configuration 3 5 TESS Options Field Description Field Underline This is how the TekTerm Server renders underlined fields sent from t
124. such offsets Systems with One Host Ifthe TekTerm Server is configured for one host named Host1 with one base named Base 1 and 20 termi nals the host session numbers are identical to the TekTerm Server terminal numbers Host Terminal Range on Communications Server 123456 7 8 9 10 11 12 13 14 15 16 17 18 19 20 Host1 1 2 3 4 s e6 7 s 9 J10 11 12 13 14 15 16 17 18 19 20 Base VODOOOVOODOOOVOVOODOVOOO Terminal ID Numbers Terminal ID 1 Terminal ID 20 Settings are as follows In the Host General Options for Host Terminal Range 1 to 20 In the Base Station General Options for Base First Terminal 1 19 4 TekTerm Server Software User Manual Systems with Multiple Hosts Terminal number mapping is useful when the TekTerm Server is configured for multiple hosts and there is a need to differentiate between terminals that communicate with one host and those that communicate with another The ranges defined for the hosts can either overlap or be mutually exclusive Two Hosts with No Overlapping Terminal Numbers Figure 19 1 Host Host Terminal Range on Communications Server 12345678 9 1l2 3 ja s 6e 7 s s Host1 ji Range of Host1 begins at Communications Server terminal 1 Terminal ID 1 Figure 19 2 Host2 Host Terminal Range on Communications Server 3 10 1 12 13 14 15 16 17 18 19 20 1l2l3jalsiel7ls s l ol Host2 A Range of Host2 begins at Communications Server terminal 10 T
125. t Protocol 2392 yes 3274 3277 3278 2 3278 2 E yes 5250 5251 11 5555 B01 yes ANSI yes 9010 TESS yes RF Modem yes HTML yes Remote sockets yes Text Conventions dh NOTE Notes highlight additional helpful information AN IMPORTANT These statements provide particularly important instructions or additional information that is critical to the operation of the equipment WARNING These statements provide critical information that may prevent physical injury equip ment damage or data loss About this Guide xiii Emulations and Datastreams Data compression and Caching Software Terminal Software Emulation Software Web Browser Host Application Terminal Station or Access Communications Server Point Host Computer The TekTerm Server performs emulation conversion the translation of data between the emulation of the host computer and the emulation used by the mobile devices The data that is sent from a host computer to a terminal and the data which is returned to the host from the terminal is called a datastream Legacy Psion devices can accept only two types of datastream TESS and ANSI TESS Teklogix Screen Subsystem is the native emulation used by the original Teklogix terminals TESS features such as page saving passthru printing and TekTerm Screen Formatter are available ANSI emulation is a standard type of datastream used by wired VT type terminals these terminals are specified by the
126. t codes see Font Code List for Open TekTerm on IngenuityWorking Font codes are only required for versions of OTT before version D Rows 0 to 24 Columns 0 to 80 Default 0 0 0 0 2 12 TekTerm Server Software User Manual AIAG Mode Values The mode character is derived by starting with the decimal value 43 ASCII character 0 zero and adding the appropriate value from the table below Code Description 1 Prevent the AlAG prefix from being displayed 2 Prevent the AIAG prefix from being sent to the host 4 Cause a transmission to the host when all AIAG fields with this mode set are filled The transmission is sent by a Function O FO code 8 Allow overwriting of previously entered data 16 Start the search for a matching AIAG field at the current cursor position Otherwise the cursor starts at the top of the page For example the symbol is used to apply the cursor matching function since adding 16 to 48 results in decimal value 64 which is the ASCII value for the character Match Characters Match Use Character Match a number amp Match a letter either case A Match an upper case letter Match a lower case letter Match an alphanumeric character j Match a letter number or space Match a punctuation character E Match any character Match all character positions in the field with the preceding character Match any remaining characters but not necessarily the remainder of the field with the prece
127. tch field feature Values 0 to 255 Default 0 For the match characters see Match Characters on page 3 12 3 10 TekTerm Server Software User Manual Hidden Match The decimal value of the special character ASCII used to tag a field to use Character hidden match mode A special character is used to mark Hidden Match fields in a TESS screen This character precedes the field contents of the Hidden Match field In hidden match fields as opposed to visible match fields the preloaded entry is not displayed in the entry field on the mobile device A value of 0 zero disables this feature Values 0 to 255 Default 0 For the match characters see Match Characters on page 3 12 Serial 1 0 The decimal value of the special character ASCII used to tag a field to use serial UO mode Serial UO fields are special entry and fixed fields that accept input from and output to a serial port The application program distinguishes this field as Serial UO by preceding the field with a special character If this character precedes a fixed field the data is sent to the serial port of the mobile device If it precedes an entry field the field accepts data from the serial port of the mobile device A value of 0 zero disables this feature Values 0 to 255 Default 0 Print Line The starting line number of the print page on the application screen A value of 1 one causes the display page to be printed A value of 0 zero disables this fe
128. ted Enable TekTerm When selected the TekTerm Server uses TekTerm Screen Formatter TekTerm Screen Formatter Screen Formatter was previously known as TSF O Default Not selected Pages The number of host screens or pages stored on the mobile device The TekTerm Server maintains an image of each page stored on the mobile device After receiving an application screen the TekTerm Server tries to match the screen with a stored page If a similar page is already in the mobile device memory the TekTerm Server instructs the mobile device to re display its copy of the page only the necessary changes are sent from the TekTerm Server If no match is found the complete page is sent to the mobile device There is a corresponding parameter on the mobile device itself and the actual number of saved pages is the smaller of the two values A value of 1 one disables this feature Values 1 to 79 Default 8 9 6 TekTerm Server Software User Manual Field Description Transmit Line When enabled all modified data on the mobile device is automatically transmitted when the operator enters data into an entry field on or above this line The value in this text box specifies the line on the screen which is designated as the transmit line The last entry field on or above the transmit line on the screen is identified as the field which will cause all modified data to be sent to the host Any entry fields that exist on lines below the transmit line will
129. ter is formatted into a 24 x 80 application screen Ifthe host can initiate the print operation the text is printed The TekTerm Server identifies the additional text as a print page by the presence of the string PRINT beginning in the 2nd column of line 13 on the 24 x 80 screen PRINT should be defined as display only text The print page is positioned below the display page ofthe mobile device see the following diagram The size of the print page is always the same as the display page of the mobile device assuming that in the mobile device configuration the page length is less than 12 lines When Host Print is enabled the TekTerm Server passes the print page to the mobile device after receiving the application screen from the host Display page 8 x 40 zl On LD d LAM Fa 8 Print Page 8 x 40 Unlike with the Passthru option when using Host Print no escape commands can be sent to the printer Support for printing must be enabled on the mobile device refer to the appropriate user manual for the mobile device for more information Default Not selected 2392 Telnet Host Configuration 7 7 Pages The number of host screens or pages stored on the mobile device The TekTerm Server maintains an image of each page stored on the mobile device After receiving an application screen the TekTerm Server tries to match the screen with a stored page If a similar page is already in the mobile device memory the TekTerm Serv
130. the PRINT key on older mobile devices The TekTerm Server sends the function response back to the host Support for printing must be enabled on the mobile device refer to the appropriate user manual for the mobile device for more information Default Not selected Pages The number of host screens or pages stored on the mobile device The TekTerm Server maintains an image of each page stored on the mobile device After receiving an application screen the TekTerm Server tries to match the screen with a stored page If a similar page is already in the mobile device memory the TekTerm Server instructs the mobile device to re display its copy of the page only the necessary changes are sent from the TekTerm Server If no match is found the complete page is sent to the mobile device There is a corresponding parameter on the mobile device itself and the actual number of saved pages is the smaller of the two values A value of 1 one disables this feature Values 1 to 79 Default 8 Field Description 5250 Telnet Host Configuration 3 7 Host Print When selected an application can send data to the display on the mobile device as well as to its attached printer The text that is passed to the printer is formatted into a 24 x 80 application screen If the host can initiate the print operation the text is printed The TekTerm Server identifies the additional text as a print page by the presence of the string PRINT beginning in the 2
131. to an entry in the TekTerm Server host table or the TekTerm Server may be able to query a domain name server Host Port The port number on the host for this connection Values 1 to 65535 Default 22 Terminal Type The type of terminal to be emulated by the TekTerm Server This must be the same as the definition on the host Default xterm Close Host session on When selected all host sessions close when the mobile device resets Terminal reset a s When not selected the sessions remain open if the mobile device resets Default Not selected Connect Without User When not selected SSH sessions from the mobile devices to the host must be Action initiated manually from the mobile devices When selected the TekTerm Server initiates one SSH session from each mobile device whose terminal number is mapped to this host Additional sessions may be initiated from each mobile device to the host but they must be initiated manually These sessions are only initiated for mobile devices which are online that is turned on and operating properly on the RF network The username and password is identical for all SSH sessions automatically logged in to this host To use this feature Username saved so users will not be prompted and Password saved so users will not be prompted must be configured Default Not selected ANSI SSH Host Configuration 5 9 Connect Prompt The text presented to the user to request a login Non printable
132. unning the TekTerm Server Using the debug console You should only use this console with the help of Psion support staff UE WA ee a WA 2 3 General Host Options Screen 2 3 3274 EmulationOptionsScreen 2 4 32 14 ee EE 2 4 TESS OplUO0NS as 44882 ar we a AA AA aa 2 5 HITML HTTP Options 4 4 ter a a a E Te od A OS 2 13 3274 Telnet Protocol Options Screen 2 13 3274 Telnet Terminal Naming Screen 2 15 3274 FunctionKeyMappingsScreen 2 16 Typical Host Configuration 2 17 Line Description ee 2 17 Controller Description 2 18 TOPP LINK 2 44 oa AP ae SRE ke Ae aa Poe erh hair 2 18 3274 Telnet Host Configuration 2 3 Overview The TekTerm Server can emulate an IBM 3274 controller connected to a number of IBM terminals The emula tion software inside the TekTerm Server converts the 3274 data transparently to and from TESS or HTTP data which is then sent to and from the Psion devices The connection between the TekTerm Server and its base stations access points and devices is transparent to the IBM host Data compression And Caching Software Emulation Host Application Software Base Terminal Station or Communications Server Access Point Host Computer General Host
133. where the Narrow Band Data proxy plug in DLL resides Default None UE WA iS ee en ee ee dh ee ey oe Ee ae be ee a ee a amp 11 3 General Host Options Screen 11 4 Other TekTerm Server Settings Associated with Remote Sockets 11 4 Mobile Device Narrow Band Configuration for Remote Sockets 11 4 Base Station Narrow Band Configuration for Remote Sockets 11 4 Remote Socket Emulation Host Configuration 11 3 Overview The Remote Sockets Emulation enables communication between a Psion computer using a narrow band radio and a host on a TCP IP network Implementing remote sockets requires a Communications Server The TekTerm Server provides the socket connections to the TCP IP network for applications running on a mobile device with a narrow band radio Remote Host Application Sockets Proxy Base Terminal Station Communications Server Host Computer Each application on the mobile device makes one or more connections through the narrow band system to the network Each connection is treated as a separate terminal on the narrow band system Narrow band radios are available on the following mobile devices e 7530 and 7530 G2 e 8525 and 8525 G2 e 8530 and 8530 G2 Remote Sockets with the Mobile Devices SDK The Remote Sockets APIs in the Mobile Devices SDK can be used to create an application on the mobile device This applicatio
134. xchange identifier Ethernet standard Maximum controllers Error threshold level Text Option Category of line Link speed Cost connect time Cost byte Security for line Propagation delay User defined 1 User defined 2 Autocreate controller LIND RSRCNAME ONLINE VRYWAIT ADPTADR EXCHID MAXCTL ENETLINE BASIC ELAN LINO21 YES NOWAIT RFCTRLENET 08005AB7C3FD 05629A5A ALL 40 OFF APPN ELAN 10M 0 0 NONSECURE LAN 128 128 NO 2 18 TekTerm Server Software User Manual Source Service Access Points SSAP Maximum Frame Type AA 1496 NONSNA Controller Description Controller description CTRD RFCTRLENET Option BASIC Category of controller NET Attached line ENETLINE Online at IPL ONLINE YES Text BLANK TCP IP Link Line description DEVD ENETLINE Internet address 50 0 1 1 Link type ELAN Auto start link YES OVERVIEW a AN 3 3 General Host Options Screen 3 3 Emulation Options Screen 3 4 Bee EECHER eee ee de 3 4 TESS OpPlONS AA ua u a EN u aa 3 5 HITML HTTP Options use eed od Aa a E 3 13 5250 Telnet Protocol Options Screen 3 14 5250 Telnet Terminal Naming Screen 3 17 Function Key Mappings Options Screen 3 18 Typical Host Configuration 3
135. y 4 9 Local 2 6 3 6 7 4 Local IP Address to Bind 2 14 3 14 4 8 7 12 log EVENT zustehen Meee ek 1 3 Lower Character Set GL 4 7 5 7 M match characters 2 12 3 12 7 11 Maximum Message Segment Size 13 4 13 6 Maximum of Auto telnet Retries 4 12 Maximum Screen Size rows x columns 4 4 5 4 Maximum Sessions per Terminal 2 14 3 14 4 8 7 12 Message Mode Limit 13 4 13 6 Message Size 12 3 Modulation ii IIIA nennen 13 7 Monitor Pole 6 4 Index 4 TekTerm Server Software User Manual N narrowband data proxy emulationoptions 10 4 general hostoptions 10 4 NDP emulationoptions 10 4 general hostoptions 10 4 Number of Poll Windows 13 4 13 6 NumberofRetries 13 4 NumberofRRMS 13 7 0 Operate in Cellular Mode 11 4 14 3 elle Aussen bees pees nee 7 4 KL KEE 7 4 ENEE 2 4 EE 3 4 802 lQ ii AAA 15 3 15102 6 EE 15 4 9010 Telnet 6 4 ANSI cid ce Saree e re ee ee ee 4 4 HTML an 9 4 miscellaneous 17 4 radio