1. O x O Ha Hard Surface Raised Flooring Panel 10 O HE N gt lt T O N Female Canopy Clips 16 O E gt lt ae Oo JO gt JU Folding Aluminum Hoops 8 Locking Pins 16 Air Frame Assembly w Attached Canopy 1 HVAC Ports 2 Male Canopy Clips 16 Zippered Folding Windows w Screens 4 Mm pr IM IN IHN e e NPN gt lt X gt lt lt gt lt lo ala Mm pr IM e e e wak gt lt 2 lt ae O IO IO 100 IN Zippered Folding Doors 2 LC12 XX 10 Exterior Wind Anchors 22 LC12 XX 11 Interior D Rings 13 LC12 XX 12 Strapped Female Clips 6 LC12 XX 13 Adjustable Structural Straps 4 Inflation Deflation Valve 1 Mm pr O IO e e Sis gt lt gt lt gt lt gt lt e e gt Pressure Release Valve 1 Receivers for Aluminum Frame 8 Manual Hand Foot Pump Duck Bill Wind Anchors w Straps 22 Storage Netting MM IT pr pr Riel ea NIN Im mo XxX X X X X X X X X X lt N e O INIO Air Beam Receivers w Foam Cushion 4 Ventilation Fan 1 LED Lights 4 Mm pr IM e jeje gt lt 2 lt lt gt X lt gt lt N e LC12 XX 24 Multi Purpose Antenna 1 LC12 XX 25 12V Dry Cell Battery 1 LC12 XX 26 Battery Meter 1 LC12 XX 27 Battery Charger 1 12V to 110V Inverter 1 110
2. RUGGED RELIABLE INSTANT SHELTER Rapid Deployment Shelter System User Manual Life Cube Inc 3463 State St 528 Santa Barbara CA 93105 USA TEL 805 682 9399 www lifecubeinc com USER MANUAL Le d LO gt lt gt gt SHELTER ASSEMBLY The Life Cube Rapid Deployment Shelter System LCRDSS is a unique and efficient way to satisfy a broad range of shelter needs The inflatable airframe assembly allows for rapid deployment and the interior aluminum assembly provides strength and rigidity Please read the following manual to ensure that your shelter is properly deployed and cared for appropriately Life Cube Rapid Deployment Shelter Systems are shipped with the following components e Shipping Container Hard Surface Raised Floor e Inflatable Canopy e Two Position Table Optional e Power Module Optional e Tie Down Kit 1 1 Serial Numbers Each LCRDSS is given its own unique serial number to assist in product tracking warranty issues and customer service concerns The format is as follows LC12MC 12 0001 TI aed Model Serial Size Year 1 2 Technical Specifications LIFE CUBE LC12 SHIPPING PACKAGE UNDEPLOYED UNIT Cube height width depth 5 feet 1 524 m standard rolling hoops Hard flooring container material ABS or Styrene Foam see package options Not less than 5 5 in 140 mm not less than 2 in 50 Flooring elevation from grade thickness mm Unit
3. Life Cube with respect to the goods delivered under this Agreement and may be modified or amended only by a written instrument signed by a corporate officer of Life Cube and accepted by the End user The products that at the End user s request are delivered without complete encapsulation are specifically excluded from the warranty set out in this Agreement All such products are sold as is If product needs repairs the following points apply e Customer pays for shipment to repair facility e Life Cube examines unit to determine if damage caused by defect or negligence If defect Life Cube reimburses shipping charge and pays for repair and return shipment e If negligence Customer pays for repair and return shipment Disclaimer No Other Warranty Except for the express warranty set forth above Life Cube grants no other warranties express of implied by statute or otherwise regarding the products their fitness for any purpose their quality their merchantability or otherwise Limitation of Liability Life Cube s liability under the warranty shall be limited to replacement repair or credit for the customer s purchase price In no event shall Life Cube be liable for the cost of procurement of substitute goods by the customer or for any special consequential or incidental damages for breach of warranty MANUAL LC12 RDSS REV B A N Y a Inn 77 ITI ws Gd Ss PARTS LIST Description
4. sure the unit is completely dry before repackaging to prevent mold 2 2 Storage While temperature is generally not an issue between 40 F and 100 F it is best to store the unit in a dry location to protect the electrical components Repairing Holes and Tears Please follow these instructions to make minor repairs to the shelter airframe Cut a patch large enough to allow 2 of overlap from the edges of the hole Avoid patching over seams when possible Clean both surfaces with thinner cleaner Avoid using oil based solvents such as paint thinner Dry the area thoroughly Apply a thin coat of adhesive to both surfaces shelter and patch Allow to dry 15 30 minutes or until it is no longer tacky to the touch Then apply another thin coat of adhesive Again allow to dry until the adhesive is no longer tacky Align the patch over the hole and press it into place start at the center and work toward the edges Roll out the entire patch area using a flat putty knife with no sharp edges Ensure all air pockets and creases are rolled out It is recommended to allow the patch to cure for two hours before use preferably overnight If waiting is not an option inflate the shelter to a slightly lower air pressure than normal On large cuts or tears it is recommended to patch both the inside and the outside of the cut or tear MANUAL LC12 RDSS REV B One Year Limited Warranty For one year after the date of shipment to End user
5. weight approximate 950 lbs typical for ABS flooring 431 kg Total weight depends on equipment configurations Maximum gross unit weight 1100 Ibs 500 kg Maximum airdrop vertical velocity 20 ft s 6 m s Maximum shock acceleration in any orientation 70 G 700 m s 10 ms max duration non repeating MANUAL LC12 RDSS REV B ae ay Maximum storage altitude Storage temperature and duration Maximum storage duration External charging maintenance port must be used to maintain battery charge during extended storage SHELTER ASSEMBLY 20 000 ft above MSL 40F to 140F 40C to 60C 1 year 2 years w out battery maintenance above freezing 5 years with battery maintenance above freezing 10 years without electrical package or food provisions LIFECUBE LC12 DEPLOYED UNIT PLEASE REFER TO DRAWING FOR UNIT DIMENSIONS Canopy and beam material Canopy color Canopy inflation time nominal deployment strike time Standard canopy CANOPY A Optional 4 door canopy CANOPY B Insulated cold hot climate canopy options Air frame inflation method Maximum deployment altitude Inflation pressure Deployment temperature range Wind resistance when fully deployed and anchored Wind resistance during canopy inflation deployment Maximum deployment grade inclination in any direction Integrated table W X D X Height lowered x Height raised approx Electrical system voltage Integrated lighting Exhaust fan air condition
6. V Electric Port 2 Solar Panel Charger 1 IM e jeje e Il gt lt X lt 2 lt 2 lt lt O IN IN W joo LC12 XX 31 Switchboard 1 LC12 XX 32 Control Panel 1 LC12 XX 33 Carbon Monoxide Alarm 1 MANUAL LC12 RDSS REV PARTS LIST LC12 XX 34 Reversible Inflator Deflator 1 Infrastructure Support Pins 30 MANUAL LC12 RDSS REV
7. ft by 24 ft 6 7 m by 7 3 m Total plan area D x W required for unit and tie downs Total unit height from flat grade including flooring excluding rain fly antennae and other vertical protrusions Not to exceed 12 ft 8 in 3 86 m Standard side fly protrusion approximately Interior clear span floor space approximately 6 ft 1 83 m 11 ft x 11 ft 3 35 m x 3 35 m 116 sq ft 10 75 Usable interior area not less than including table Doorway opening dimensions W x H at least 3 ft x 6 ft 0 91 m x 1 82 m MANUAL LC12 RDSS REV B SHELTER ASSEMBLY MANUAL LC12 RDSS REV B SHELTER ASSEMBLY MANUAL LC12 RDSS REV B INTERIOR ASSEMBLY MANUAL LC12 RDSS REV B gt 1 LL N V lt O MANUAL LC12 RDSS REV B gt 1 LL V V lt MANUAL LC12 RDSS REV DISASSEMBLY MANUAL LC12 RDSS REV B DISASSEMBLY MANUAL LC12 RDSS REV B DISASSEMBLY MANUAL LC12 RDSS REV B 2 Care and Maintenance The LCRDSS is extremely rugged and requires little maintenance However it is important to keep the unit dry and clean to reduce complications in future deployments 2 1 Cleaning Before repackaging be sure to clear all debris with a broom or with the included blower If the unit has been deployed in dusty or muddy areas it may be necessary to wipe the unit down with a water bleach mix Make
8. ing Standard electrical connectivity Please refer to package info for solar power packages available in 60W increments Critical energy reserve capacity OSHA MSHA fire retardant airtight thermoplastic material Standard tan green white camouflage or custom colors optional lt 5 min on full charge 5 min 20 min 2 people 3 doors 4 windows 18 tie points 1 shade fly optional flies 4 doors 0 windows 12 tie points optional rain fly Insulated walls ceiling insulating window material Electric Blower accessible valve port 15 000 ft 4500m not less than 3 psig 20 7 kPa 22F to 122F 30C to 50C Not to exceed 50 mph 22 m s Not to exceed 18 mph 9 m s Not to exceed 15 Aluminum removable telescoping gas stove 48 x 48 x 23 x 30 inches 1 22 x 1 22 x 0 58 x 0 76 m 12V DC 10 6V 14 6V 20W LED utility 5W LED emergency Multi speed exhaust fan optional A C duct connection External charging port 2x 12V 15A sockets AC Charger field selectable 100 240VAC 50 60Hz AC Inverter 120VAC 2x inflations 10 hours of Sw emergency lighting MANUAL LC12 RDSS REV B gt 2355 FRG UB SHELTER ASSEMBLY LIFE CUBE LC12 DEPLOYED UNIT DIMENSIONS Depth including porch excluding all awning and flies Not to exceed 16 ft 4 in 5 m Not to exceed 12 ft 4 in 3 8 m Width excluding all awning and flies Width with standard fly Not to exceed 20 ft 0 in 6 1 m Approximately 22
9. or eighteen months after the date of shipment from Life Cube whichever first occurs Life Cube will at its sole discretion replace repair or furnish credit for any product purchased by End user that in Life Cube s judgment has a defect in material or workmanship provided the product is returned transportation charges prepaid to Life Cube with Life Cube s prior permission and return authorization number and provided further that the product has not been misused improperly operated or subject to unauthorized repairs or modifications This warranty is in lieu of all other warranties expressed implied or statutory including the warranty of merchantability and the warranty of fitness or of suitability for a particular purpose and of all other obligations or liabilities on Life Cube s part and Life Cube neither assumes nor authorizes any other person to assume for Life Cube any other liabilities in connection with the sale of the said product If Life Cube s examination does not disclose a defect in material or workmanship on a product claimed to be defective The Distributor agrees to pay Life Cube s established charges for unpacking testing and repackaging the product for reshipment to the End user This provision states the End user s exclusive and sole remedy for breach of warranty This provision does not extend the original warranty period of any product that has been repaired or replaced by Life Cube This warranty is the only warranty made by