Home
SA-PAM-SAN-ETH SA-PAM-SAN-ETH-ROHS SA
Contents
1. 2 5 3 Unittermination nanna aA 2 6 ee enc 22 6 1 TADS vives a 22 S Access GmbH Tel 41 44 700 31 11 Oberhausenstrasse 47 Page 3 of 28 Fax 41 44 700 31 03 8907 Wettswil JA Email contact s access ch Switzerland WEB www s access ch SA PAM SAN Eth 7 TECHNICAL SPECIFICATIONS 8 STORAGE CONDITIONS 9 CONNECTOR S DESCRIPTION 9 1 DSL Connector 9 2 DSL Connector for SRL units 9 3 Monitor Connector 9 4 PC and Hub Connectors 9 5 Line1 and Line2 Connector 10 DESCRIPTION OF INTERFACE CABLES 10 1 Ethernet cable 10 2 DSL cable S Access GmbH Oberhausenstrasse 47 8907 Wettswil JA Switzerland User Manual Page 4 of 28 Tel 41 447003111 Fax 41 44 700 31 03 Email contact s access ch WEB www s access ch SA PAM SAN Eth User Manual MPE VERSION CONTROL Version Date Major changes to previous version 1 0 31 12 2001 Initial version of the manual corresponding to version 1 2 of the device micro program 1 1 23 10 2003 New function description corresponding to software release V1 6 Corrected Connecter description 9 1 Changed DSL cable to twisted type 10 2 1 2 26 1 2004 Manual corresponding to software version 1 7 Implementation of SRL models 1 3 07 7 2004 Added Connecter drawing 8 2 Manual corresponding to software version 1 8 Small Text
2. unsnennsenennnsannnnnnnnnnnnnnnannnnnnnnn nn 12 3 2 The SRL SubRackCard delivery Set nn 12 3 3 Connection rules Le rna rna anna 12 3 4 Communication parameters of the terminal 12 4 THE COMMAND SV ST EM A 14 4 1 BASIC TUlCS Here a e b f f 14 4 2 The main a ENa na 14 4 3 Performance management 15 4 3 1 Loop Status submenu 15 4 3 2 Ethernet Status submenu 16 4 4 Configuration 16 e 7 gt 1 o an B 17 4 4 2 Ethernet 5 8 19 4 4 3 Profile submenu nn 20 4 5 Security management 20 5 TIFIPFUPLORB zusenden E 21 5 1 Unit preparation nn nn nn 2 5 2 PC Software download e
3. Configuration Management gt DSL Setup 1 Loop 1 Operation Mode Slave 2 Loop 1 Auto Fixed Fixed 5 Loop 1 Fixed Connection Speed 2312K 36N 6 Loop 1 Annex A B 7 Loop 1 Tx Level Adjustment 0 dB 18 2W 4W 2 Select item number or ESC to Upper level menu gt gt 4 4 1 1 Operation Mode In this menu you can setup the unit to one of the following states Master Slave 4 4 1 2 Auto Fixed This Menu is NOT available if the unit is in AW mode Except the unit has firmware version 2 41 Ask support s access ch if you like to get this special version In this Menu you can setup the unit to one of the following states Auto Fixed If Auto is selected the unit works in the adaptive mode If Fixed is selected the unit works with fixed line rates 4 4 1 3 Min Max Connection Speed only if Auto selected and FW 2 41 for 4W e In the Min Max Connection Speed menu you can specify your desired Adaptive mode speed limit borders in the range of 72 kbps to 2312 kbps for 2wire units and 528 kbps to 4624 kbps for 4wire models S Access GmbH Tel 41 44 700 31 11 Oberhausenstrasse 47 Page 17 of 28 Fax 41 44 700 31 03 8907 Wettswil JA Email contact s access ch Switzerland WEB www s access ch SA PAM SAN Eth User Manual S Access 4 4 1 4 Fixed Connection Speed only if Fixed is selected e Inthe Fixed Connection Speed menu you can specify your desired speed in the range of 72 kbps to 23
4. 1 PORT2 Informs the user about FXO FXS activity on port 2 S Access GmbH Tel 41 44 700 31 11 Oberhausenstrasse 47 Page 8 of 28 Fax 41 44 700 31 03 8907 Wettswil a A Email contact s access ch Switzerland WEB www s access ch SA PAM SAN Eth User Manual S Access The back panel of the SA PAM SAN Eth ROHS modem has POWER xDSL MONITOR HUB Jo The grounding bolt of the modem option The 12Vdc POWER connector The connection of the modem to the 220 V power supplv is implemented using an external power supply unit e the Monitor connector to control the modem and store statistics e HUB connector to connect the modem to the LAN using a straight Patch Cord the DSL connector to connect the modem to the leased physical line The back panel of the SA PAM SAN Eth modem has additionally MONITOR xDSL OO LI PC connector to connect the modem to the LAN using a straight Patch Cord The back panel of the SA PAM SAN Eth FXO FXS modem has additionally LINE1 LINE2 MONITOR xDSL gL 6 0 The LINE1 and LINE2 connector to connect to PABX FXO model or to telephone FXS model S Access GmbH Tel 41 44 700 31 11 Oberhausenstrasse 47 Page 9 of 28 Fax 41 44 700 31 03 8907 Wettswil a A Email contact s access ch Switzerland WEB www s access ch SA PAM SAN Eth User Manual MPE 2 2 Exterior design SRL models
5. SAN Eth User Manual S Access 3 RULES OF SWITCHING 3 1 The SAN Stand alone delivery set The delivery set includes e the subscriber access device a modem e the power supply source an AC adapter e the cables for the line connections 3 2 The SRL SubRackCard delivery set The delivery set includes e the subscriber access device a module e the cables for the line connections 3 3 Connection rules During the connection of the modem stick to the following rules e connect the modem using the straight Patch Cord cable to the hub through the HUB connector or to the PC through the PC connector Only one device can be connected to modem jack at same time e connect the modem if necessary to the serial port of the PC through the MONITOR connector using the straight modem cable e connect the modem to the line using the DSL connector e connect the power supply unit to the AC power system e connect the modem to the power adapter using the DC 12V connector it s necessary to use 13 5V adapter for FXS models e launch the hyper terminal operation program on the PC 3 4 Communication parameters of the terminal configuration It is necessary to set the following parameters to monitor the modem e transmission rate 9600 data bits 8 parity none e number of stop bits 1 e flow control None S Access GmbH Tel 41 44 700 31 11 Oberhausenstrasse 47 Page 12 of 28 F
6. Vac power For SA PAM SAN Eth FXO FXS e up to 2 voice cannel S Access GmbH Tel 41 44 700 31 11 Oberhausenstrasse 47 Page 6 of 28 Fax 41 44 700 31 03 8907 Wettswil JA Email contact s access ch Switzerland WEB www s access ch SA PAM SAN Eth User Manual S Access ORDER INFORMATION SA PAM SAN Eth Modem S Access Discovery Tabletop G shdsi 10 100Base T Bridge VLAN Adapter 230 Vac SA PAM SAN Eth ROHS RoHS Ready Modem S Access Discovery Tabletop G shdsl 10 100Base T Bridge VLAN Adapter 230 Vac SA PAM SRL Eth Modem S Access Discovery SubRack G shdsl 10 100Base T Bridge VLAN Adapter 230 Vac SA PAM SAN Eth 4W Modem S Access Discovery Tabletop G shdsl 2 pairs up to 4 6Mbps 10 100Base T Bridge VLAN Adapter 230 Vac SA PAM SRL Eth 4W Modem S Access Discovery SubRack G shdsl 2 pairs up to 4 6Mbps 10 100Base T Bridge VLAN Adapter 230 Vac SA PAM SAN Eth FXS Modem S Access Discovery Tabletop G shdsi 10 100Base T Bridge VLAN Adapter 230 Vac with FXS interfaces SA PAM SRL Eth FXS Modem S Access Discovery SubRack G shdsl 10 100Base T Bridge VLAN Adapter 230 Vac with FXS interfaces SA PAM SAN Eth FXO Modem S Access Discovery Tabletop G shdsi 10 100Base T Bridge VLAN Adapter 230 Vac with FXO interfaces SA PAM SRL Eth FXO Modem S Access Discovery SubRack G shdsl 10 100Base T Bridge VLAN Adapter 230 Vac with FXO interfaces S Access GmbH Tel 41 44 700 31 11 Oberhausenstr
7. connector for the observation of the download procedure e Enter the Ethernet Setup submenu e Enter menu point Enable TFTP Server and switch TFTP on e Exit menu point Enable TFTP Server e Enter the Profile Submenu and Save the settings to Profile 0 e Restart the unit 5 2 PC Software download e Unzip the download file to an empty directory e If necessary rename the actual bin file to all bin e Open the cmd exe windows menu Start Run cmd e Enter the directory with the unzipped files e Enter the following command I xx xx xx xx PUT all bin e Wait until the program terminates check it on the PC Terminal e Close the cmd exe windows menu 5 3 Unit termination e Enter the Ethernet Setup submenu e Enter menu point Enable TFTP Server and switch TFTP off e Exit menu point Enable TFTP Server e Enter the Profile Submenu and Save the settings to Profile 0 e Restart the unit S Access GmbH Tel 41 44 700 31 11 Oberhausenstrasse 47 Page 21 of 28 Fax 41 44 700 31 03 8907 Wettswil JA Email contact s access ch Switzerland WEB www s access ch SA PAM SAN Eth User Manual S Access 6 SNMP 6 1 Traps The unit supports the following traps Trap Description Cold start Sent on unit startup Linkup Sent on DSL link up Linkdown Sent on DSL link loss Authorization Error Sent on reception of a wrong community string hacker attack S Access GmbH Tel 41 44 700 31 1
8. range 30 C 75 C Operating Temperature range 50 C 75 C Relative humidity of air 5 85 S Access GmbH Tel 41 44 700 31 11 Oberhausenstrasse 47 Page 23 of 28 Fax 41 44 700 31 03 8907 Wettswil JA Email contact s access ch Switzerland WEB www s access ch SA PAM SAN Eth User Manual S Access 8 STORAGE CONDITIONS The equipment of the S Access family while being packed should withstand all means of transport at a temperature in the range form 50 C to 75 C and the relative humidity of air up to 100 at 25 C The equipment can also withstand air transport at a low air pressure of 12 kPa 90 Torr at 50 C The packed equipment of the S Access family can be stored within 12 months from the date of transshipment including transporting time in storage rooms without heating at 50 C 75 C and the mean monthly value of the air humidity of 80 at 20 C short term increases of air humidity up to 98 no more than a month a year at a temperature not exceeding 25 C without moisture condensation is admissible The equipment should be stored in storage buildings which protect the devices from atmospheric precipitations The equipment should be kept on shelves or in factory packages in the absence of vapors of acids alkali and other atmospheric impurities S Access GmbH Tel 41 44 700 31 11 Oberhausenstrasse 47 Page 24 of 28 Fax 41 44 700 31 03 8907 Wettswil JA Email contact s access ch Switzerland W
9. 1 Oberhausenstrasse 47 Page 22 of 28 Fax 41 44 700 31 03 8907 Wettswil JA Email contact s access ch Switzerland WEB www s access ch SA PAM SAN Eth User Manual S Access 7 TECHNICAL SPECIFICATIONS The main technical specifications of modems of the S Access family are presented below in the table Line interface Standard ETSI 101 135 Regulation RoHS RoHS ready Pb free Number of pairs 1or2 Line rate 2 wire models 72 2320 Kbit s 4 wire models 144 4624 Kbit s Communication range for cables with 0 4 mm 0 9 mm the wire diameter of approx approx N 8 2 km 31 km za 3 6 km 13 7 km values are depending on noise environment and line quality Line code G shdsl TC PAM Input impedance of the physical line 135 Ohm Output signal level 0 5dBm 15 5 dBm Transmission spectrum from 0 450 kHz User s interface Standard IEEE 802 3 IEE 802 1Q Interface type Ethernet 10 100Base T Full Half Duplex Connector RJ 45 Management Monitoring VT100 Telnet SNMP Power supply Supply voltage Stand alone JSAN model 230 Vac 10 50 Hz power adapter Sub Rack Card SRL model 36Vdc 72Vdc Power consumption No more than 5 W Grounding resistance No more than 10 Ohm Protection Conforms to the requirements of the GOST State Standard 12 2007 0 85 GOST 7153 85 GOST P 50033 92 and Norm 9 93 Climatic conditions Storage Temperature
10. 12 kbps for 2wire units and 528 kbps to 4624 kbps for 4wire models 4 4 1 5 Annex With the Appendix menu you can choose between A B A B If you don t know what Annex you have to setup then use the A B configuration 4 4 1 6 Tx Level Adjustment e Inthe Tx Level Adjustments menu you can setup you desired TX output level in the range from 2dB to 13dB Please note changing the default value of 0 to another value may cause serious malfunction of the DSL line It should be changed only by qualified personal 4 4 1 7 2W 2CH 4W In the 2W 4W 2wire 4 wire Adjustments menu you can setup you desired number and mode of the DSL line The following modes are possible 2W 1 DSL line normal mode AW 2 DSL lines dual pair mode 4W models only 2CH 2 DSL lines multipoint mode 4W models only S Access GmbH Tel 41 44 700 31 11 Oberhausenstrasse 47 Page 18 of 28 Fax 41 44 700 31 03 8907 Wettswil JA Email contact s access ch Switzerland WEB www s access ch SA PAM SAN Eth User Manual S Access 4 4 2 Ethernet Setup submenu Configuration Management gt EtherNet Setup Speed Auto Duplex Mode Auto Disable Mac Filter No IP Address gt gt 192 168 5 105 Subnet Mask gt gt 255 255 255 0 Gateway Address gt gt 192 168 5 1 NOP WN 8 NMS IP Address gt gt 192 168 5 32 9 Read Community gt gt 10 Write Community gt gt 11 Trap Community gt gt 12 Enable TFTP Server N
11. Auto Fixed Fixed Clock Source Follow Loop Annex A B Fixed Speed 2312K 36N 1 Disconnect Select item number or ESC to Upper level menu gt gt S Access GmbH Tel 41 44 700 31 11 Oberhausenstrasse 47 Page 15 of 28 Fax 41 44 700 31 03 8907 Wettswil JA Email contact s access ch Switzerland WEB www s access ch SA PAM SAN Eth User Manual S Access 4 3 2 Ethernet Status submenu Upon activation of the performance management submenu the following message will be displayed Performance Management gt EtherNet Status Link Link down Link Speed Link Duplex Used Entries 0 Tx Packets 0 Rx Packets 0 Fwd Packets 0 Drop Packets 0 Speed Auto Duplex Auto MAC Address 00 0E 00 02 01 FD 1 Clear Counters Select item number or ESC to Upper level menu gt gt 4 4 Configuration management submenu Upon activation of the configuration management submenu the following message will be displayed Configuration Management 1 DSL Setup 4 EtherNet Setup 6 Profile Select item number or ESC to Upper level menu gt gt S Access GmbH Tel 41 44 700 31 11 Oberhausenstrasse 47 Page 16 of 28 Fax 41 44 700 31 03 8907 Wettswil JA Email contact s access ch Switzerland WEB www s access ch SA PAM SAN Eth User Manual S Access 4 4 1 DSL Setup In this menu you can setup the DSL link When you have selected that menu the following will appear
12. EB www s access ch SA PAM SAN Eth User Manual 9 CONNECTOR S DESCRIPTION 9 1 DSL Connector Type RJ 45 8 pin Number Signal Assignment 1 2 NC RJ 45 3 LB a tip 4W model only 4 LA a tip 5 LA b ring 6 LB b ring 4W model only 7 8 NC 9 2 DSL Connector for SRL units Type RJ 45 8 pin Number Signal Assignment 1 LB a tip 4W model only RJ 45 2 LB b ring 4W model only 3 NC 4 LA a tip 5 LA b ring 6 7 8 NC S Access GmbH Tel 41 44 700 31 11 Oberhausenstrasse 47 Page 25 of 28 Fax 41 44 700 31 03 8907 Wettswil JA Email contact s access ch Switzerland WEB www s access ch SA PAM SAN Eth 9 3 Monitor Connector Type Sub D9 female DB9 female 9 4 PC and Hub Connectors Type RJ 45 S Access GmbH Oberhausenstrasse 47 8907 Wettswil JA Switzerland Number N O oO A O N User Manual Number Signal Assignment 1 NC 2 TXD Transmit data 3 RXD Receive data 4 DTR Data terminal ready 5 SGND Signal ground 6 NC 7 NC 8 NC 9 NC PC assignment HUB assignment TX Tx Rx NC NC Rx NC NC Page 26 of 28 Tel 41 44 700 3111 Fax 41 44 700 31 03 Email contact s access ch WEB www s access ch SA PAM SAN Eth User Manual 9 5 Line1 and Line2 Connector Type RJ 11 4 pin Number Signal 1 NC RJ 11 2 LA a 3 LA b 4 NC S Access Gm
13. S Access GmbH Tel 41 44 700 31 11 Oberhausenstrasse 47 Page 10 of 28 Fax 41 447003103 8907 Wettswil a A Email contact s access ch Switzerland WEB www s access ch SA PAM SAN Eth User Manual S Access Status L informs the user about the status of the local device The following four statuses are possible blinking red informs the user about malfunctioning of the modem s hardware and software In this case the modem is out of order and should be submitted to the service center for being repaired red informs the user about an urgent alarm An abruption of the connection the correspondence of the signal to noise ratio which does not allow to transmit information and a great number of errored blocks can cause an urgent alarm amber informs the user about non urgent alarms An abruption of connection over the user s interface can cause non urgent alarms green absence of alarms Normal functioning of the device Status R informs the user about the status of the remote device At the time being the remote configuring of modems is not provided Ethernet The LED is lit upon an incorrect connection to the LAN The LED is blink upon the detection of packets in the segment of the current LAN S Access GmbH Tel 41 44 700 31 11 Oberhausenstrasse 47 Page 11 of 28 Fax 41 44 700 31 03 8907 Wettswil JA Email contact s access ch Switzerland WEB www s access ch SA PAM
14. User Manual SA PAM SAN ETH SA PAM SAN ETH ROHS SA PAM SAN ETH 4W SA PAM SAN ETH FXO SA PAM SAN ETH FXS SA PAM SRL ETH SA PAM SRL ETH 4W SA PAM SRL ETH FXO SA PAM SRL ETH FXS G SHDSL Modem USER MANUAL Version 1 6 Revision 9 September 2005 Document name UM_SA PAM SAN Eth_v1 6 doc SA PAM SAN Eth User Manual S Access Copyright 2005 by S Access GmbH The contents of this publication may not be reproduced in any part or as a whole transcribed stored in a retrieval system translated into any language or transmitted in any form or by any means electronic mechanical magnetic optical chemical photocopying manual or otherwise without the prior written permission of S Access GmbH Published S Access GmbH All rights reserved S Access GmbH Tel 41 44 700 31 11 Oberhausenstrasse 47 Page 2 of 28 Fax 41 44 700 31 03 8907 Wettswil JA Email contact s access ch Switzerland WEB www s access ch SA PAM SAN Eth User Manual S Access VERSION EONTROL 5 1 6 ORDER INFORMA TION une 7 2 DESCRIPTION OF THE DEVICE ii i d 8 2 1 Exterior design SAN M dels unse ee 8 2 2 Exterior design SRL Models 10 3 RULES OF SWITCHING 12 3 1 The SAN Stand alone delivery set
15. asse 47 Page 7 of 28 Fax 41 44 700 31 03 8907 Wettswil JA Email contact s access ch Switzerland WEB www s access ch SA PAM SAN Eth 2 DESCRIPTION OF THE DEVICE 2 1 Exterior design SAN models The front panel of the device has 3 LEDs FXO and FXS has 2 additional LEDs STATUSO WANO LANO PORTIO PORTO LOCAL informs the user about the status of the local device The following four statuses are possible blinking red informs the user about malfunctioning of the modem s hardware and software In this case the modem is out of order and should be submitted to the service center for being repaired red informs the user about an urgent alarm An abruption of the connection the correspondence of the signal to noise ratio which does not allow to transmit information and a great number of errored blocks can cause an urgent alarm See the Command menu chapter for detail amber informs the user about non urgent alarms An abruption of connection over the user s interface can cause non urgent alarms green absence of alarms Normal functioning of the device WAN informs the user about the status of the remote device At the time being the remote configuring of modems is not provided LAN The LED is lit upon an incorrect connection to the LAN The LED is blink upon the detection of packets in the segment of the current LAN PORT1 Informs the user about FXO FXS activity on port
16. ax 41 44 700 31 03 8907 Wettswil JA Email contact s access ch Switzerland WEB www s access ch SA PAM SAN Eth User Manual S Access To update the information on the screen use the Enter key The following menu will appear on the screen Input Password Please enter your programmed password The unit will be delivered without a password if there is a password default password admin After entering the password the following menu will appear Discovery G SHDSL Ethernet Monitor V2 42 Main Menu Performance management PM 3 Configuration management CM Security management SM 5 Exit Console ws Select item number or ESC to Upper level menu gt gt The modem is ready to be configured S Access GmbH Tel 41 44 700 31 11 Oberhausenstrasse 47 Page 13 of 28 Fax 41 44 700 31 03 8907 Wettswil JA Email contact s access ch Switzerland WEB www s access ch SA PAM SAN Eth User Manual S Access 4 COMMAND SYSTEM 4 1 Basic rules After the command is typed press lt enter gt The lt Backspace gt key is used to edit commands It is necessary to input item number for choosing menu item You can use PageUP PageDown and Space keys for scrolling list of available value of parameters The Esc key is using for canceling of new value of parameters or returning to up menu screen 4 2 The main menu The main menu is the foll
17. bH Oberhausenstrasse 47 Page 27 of 28 8907 Wettswil JA Switzerland Assignment tip ring Tel 41 447003111 Fax 41 44 700 31 03 Email contact s access ch WEB www s access ch SA PAM SAN Eth User Manual S Access 10 DESCRIPTION OF INTERFACE CABLES 10 1 Ethernet cable Side A Color of wire Side B 1 white green 1 2 green white 2 3 white orange 3 4 blue white 4 5 white blue 5 6 orange white 6 7 white brown 7 8 brown white 8 10 2 DSL cable Side A Color of wire Side B 1 white green 1 2 green white 2 3 white orange 3 4 blue white 4 5 white blue 5 6 orange white 6 7 white brown 7 8 brown white 8 S Access GmbH Tel 41 44 700 31 11 Oberhausenstrasse 47 Page 28 of 28 Fax 41 44 700 31 03 8907 Wettswil JA Email contact s access ch Switzerland WEB www s access ch
18. changes 1 4 11 2 2005 Manual corresponding to software version 1 9s SNMP topic implemented TFTP topic implemented Small Text changes 1 5 2 8 2005 Manual corresponding to software version 2 4 CE Model implemented topic modified 1 6 9 9 2005 Manual corresponding to software version 2 42 Modified 4 4 1 3 topic modified S Access GmbH Tel 41 44 700 31 11 Oberhausenstrasse 47 Page 5 of 28 Fax 41 44 700 31 03 8907 Wettswil JA Email contact s access ch Switzerland WEB www s access ch SA PAM SAN Eth User Manual MPE 1 GENERAL INFORMATION e High speed svmmetrical data transmission over one phvsical copper twisted pair with the 135 Ohm impedance according to ETSI TS 101 135 e ITU T G 991 2 G shdsl line encoding e Line rate in the range from 72 Kbit s to 2320 Kbit s Line rate in the range from 144 Kbit s to 4624 Kbit s 4W models only e Manual or automatic mode of line speed adjustment e Ethernet 70 100Base T interface Full Half duplex e Transmission of VLAN packet IEEE 802 1Q e Dynamic table formation of MAC addresses e Accumulation of up to 1024 MAC addresses e Granting of 95 of the digital channel band to the user In built functions of diagnostics and self testing e Low power consumption easy to use applications e Console port for the local management e Telnet port for the local remote management e SNMP Management e Remote TFTP Software upload e 230
19. o Select item number or ESC to Upper level menu gt gt e Inthe Speed menu you can setup the Ethernet speed to the following states 10M 100M or Auto e Inthe Duplex Mode menu you can setup the Ethernet ports to the following states Half Full or Auto e Inthe IP Address Subnet Mask and Gateway Address menu you can setup the desired Ip settings e Inthe NMS IP Address menu you can setup the IP receiver address for the SNMP traps the Network Manager e In the Read Write Trap Community menu you can setup the desired SNMP community address names text TFTP Server S Access GmbH Tel 41 44 700 31 11 Oberhausenstrasse 47 Page 19 of 28 Fax 41 44 700 31 03 8907 Wettswil JA Email contact s access ch Switzerland WEB www s access ch SA PAM SAN Eth User Manual S Access 4 4 3 Profile submenu Users can save and load up to 4 profiles for different tasks The Profile 0 is the default profile during power on Users have to save all new value of parameters before power off 4 5 Security management submenu The security management is using for setting the desired password for the console access S Access GmbH Tel 41 44 700 31 11 Oberhausenstrasse 47 Page 20 of 28 Fax 41 44 700 31 03 8907 Wettswil JA Email contact s access ch Switzerland WEB www s access ch SA PAM SAN Eth User Manual S Access 5 UPLOAD 5 1 Unit preparation Its suggested to connect the PC Terminal to the monitor
20. owing Discovery G SHDSL Ethernet Monitor V2 42 Main Menu Performance management PM 3 Configuration management CM Security management SM 5 Exit Console Select item number or ESC to Upper level menu gt gt The menu consists of five submenus To choose the needed submenu it is necessary to type its number and press Enter The main menu also contains information about the current version of the firmware It is important that you inform the service center about it when being consulted S Access GmbH Tel 41 44 700 31 11 Oberhausenstrasse 47 Page 14 of 28 Fax 41 44 700 31 03 8907 Wettswil JA Email contact s access ch Switzerland WEB www s access ch SA PAM SAN Eth User Manual MTENNI 4 3 Performance management submenu Upon activation of the performance management submenu the following message will be displaved Performance Management 1 Loop Status A EtherNet Status Select item number or ESC to Upper level menu gt gt 4 3 1 Loop Status submenu Upon activation of the performance management submenu the following message will be displaved Performance Management gt Loop Status System Up Time 0 Day 00 16 31 Loop 1 Loop Up Time 0 Day 00 15 07 Operation State Data Line Speed 2312K Rx Gain 5 43 dB Tx Power 14 50 dBm S N Ratio 37 74 dB Framer Status In sync Loop Atten 0 19 dB Operation Mode Slave
Download Pdf Manuals
Related Search
Related Contents
Guia de Hardware IEEE 802.3at Gigabit High Power over Ethernet Injector POE Panasonic KX-TG2340JX telephone Catalogues chinois et birmans à la bibliothèque du Congrès Grille-horaire du 3e degré (non immersion) Mode d`emploi et balises M2MI_MWE 17 Inox Grill Samsung GT-E1081T Керівництво користувача Spécifications techniques manual (PDF/10MB) Copyright © All rights reserved.