1. 7 Space required for servicing the machine should be considered before installation Environmental Specification temperature amp humidity IE 5 C 35 C 41 F 95F o Temperature In In Storage 0 C 40 C 32 F 104F umidi Power Requirements 100W Free Voltage Main Power Supply 90 264VAC SP HYOSUNG NAUTILUS HYOSUNG INC MX 4000W Installation Manual ATM Dimension Front View AM m s 478 0 18 82 482 0 18 98 643 0 25 31 ATM Dimension Plan View 643 0 25 31 62 3 2 45 324 7 12 78 SP HYOSUNG NAUTILUS HYOSUNG INC MX 4000W Installation Manual ATM Dimension Side View 34 2 1 35 Gi HYOSUNG MAUTILUS HYOSUNG INC MX 4000W Installation Manual Installation and Service Clearance Following diagram is describing the areas required for installing and servicing the MX 4000W NOTE All the unit in the dimension is mm and is inch scale Hyousng recommends it is more convenient for your service personnel to have enough maintenance space as described below to service this ATM machine 744 0 29 29 dA m jJ p aea CI O K O i co O CI O co 455 6 17 94 11 Gi HYOSUNG NAUTILUS HYOSUNG INC MX 4000W Installation Manual Packing Dimensions In some cases it may be necessary to store the ATM in its box before it is installed See figure below for information on the dimensions of out box including tw
2. Do not place the equipment where the floor cannot sustain the weight of the equipment or on slanted or unstable surface Equipment may fall down and cause injury or damage CAUTION 1 TO REDUCE THE RISK OF FIRE USE ONLY No 26 AWG OR LARGER TELECOMMUNICATION LINE CORD 2 RISK OF EXPLOSION IF BATTERY IS REPLACED BY AN INCORRECT TYPE DISPOSE USED BATTERIES ACCORDING TO THE INSTRUCTIONS 3 FOR PLUGGABLE EQUIPMENT THE SOCKET OUTLET SHALL BE INSTALLED NEAR THE EQUIPMENT AND SHALL BE EASILY ACCESSIBLE 4 THE EQUIPMENT IS TO BE SECURED TO THE BUILDING STRUCTURE BEFORE OPERATION 5 A SECURITY CONTAINER SHALL BE PERMITTED TO OPTIONALLY BE PROVIDED WITH A SECONDARY LOCK BUT IMPROPER USE OF THE SECONDARY LOCK FEATURE WILL REDUCE THE SECURITY LEVEL OF THE ATM SP HYOSUNG NAUTILUS HYOSUNG INC MX 4000W Installation Manual Installation Information Installation condition and space Following conditions should be met before installing equipment 1 Temperature while operating should be between 41 F 95 F 2 Relative humidity while operating should be between 25 lt RH lt 85 Non Condensed 3 Avoid locations where intense direct light is reflected off the LCD screen 4 Avoid locations where strong static electricity can occur 5 Avoid placing the product next to equipment that produces electromagnetic waves It could interfere with data transfer 6 The floor must allow easy wheelchair access from the front or the side
3. HYOSUNG NAUTILUS HYOSUNG INC MX 4000W Installation Manual Fig 5 To help meet ADA guidelines it is recommended that the bottom of the mounting frame bracket is 1m 39 37inch off the floor 11 5 0 45 1000 0 39 37 Gi HYOSUNG MAUTILUS HYOSUNG INC MX 4000W Installation Manual Fig 6 Hanging the ATM on the mounting frame bracket 18 SP HYOSUNG NAUTILUS HYOSUNG INC MX 4000W Installation Manual Fig 7 Hanging the ATM on the mounting frame bracket and fastening the screws 6ea SP HYOSUNG NAUTILUS HYOSUNG INC MX 4000W Installation Manual Fig 8 Taking out the power amp LAN cable from the ATM To take the power cable and LAN cable out of the ATM separate the bracket on the bottom inside the ATM After taking them out place the bracket on its original position Power amp LAN Cable Hole when installing MX 4000W on the wall 20 G HYOSUNG NAUTILUS HYOSUNG INC MX 4000W Installation Manual Fig 9 The external appearance after the completion of installation D I O i O i C og n o o or 3 ei hs N O lt p lt L S Sr g S E H O CO v N W O 0 3 sa 02 lt as IBS L sa A L S c Gl O I 0 O W 5 W 9 De co O E O O de LL a 8 278 9 10 21 G HYOSUNG NAUTILUS HY SUNG INC
4. to provide installation guide for the MX 4000W ATM and provide detailed description of the following e Information for installation e Environmental Specification e Power Specification All information described in this manual is a licensed product of Nautilus Hyosung Corporation It is the policy of Nautilus Hyosung Corporation to improve products as new technology components software and firmware become available Therefore Nautilus Hyosung reserves the right to change specifications without notice SP HYOSUNG NAUTILUS HYOSUNG INC MX 4000W Installation Manual Warning Signs Common Precaution for Safety Precautions outlined this manual provide information on safe and proper handling of the product Non compliance of the precautions may result in injury or damage to the product This precaution symbol with sample term tells you safety warnings during equipment handlings Please read the following instructions before operating equipment 1 Operate equipment in the order outlined in this manual 2 Follow precautions indicated in this manual as well as the equipment itself Failure to properly address these precautions may lead to injury or damage to the product 3 Avoid operations not addressed in this manual 4 If you cannot remedy system problems using the methods outlined in this manual please refer to contact information listed in the manual 5 Any change or modifications in construction of this device which ar
5. MX 4000W Installation Manual S HYOSUNG NAUTILUS HYOSUNG INC Copyright 2011 Nautilus Hyosung Inc All right reserved MX 4000W Installation Manual Revision Record DATE PAGE VERSION DESCRIPTION OF CHANGE December 2011 New Publication SP HYOSUNG NAUTILUS HYOSUNG INC MX 4000W Installation Manual Table of Contents MON ere 4 Warning Signs EE NE NE NE EN EN E NE EE 5 Common Precautions for Safety ir i ee mei 5 Description of Precaution Symbols eee 6 Installation Iniormalionia i cca aiar 8 Installation Condition and Space ie 8 Environmental Specification Temperature amp Humidity eee 8 Power Requirements iii 8 ATM Dimension Front View seen 9 ATM Dimension Plan View iii iii ica 9 ATM Dimension Side View iene 10 Installation and Service Clearance ninni iii 11 Packing Dimensions rie 12 System No 13 Unpacking iii eee eee 13 Physical Installation Wall Mounting iii ee eee 14 3 Gp HYOSUNG NAUTILUS HYOSUNG INC MX 4000W Installation Manual Introduction The MX 4000W is a wall mounted ATM and designed to meet the everyday demands of immediate cash needs for individuals with a compact size to fit in virtually any place This Automated Teller Machine ATM is connected to a network processor to verify accounts and any other inquires through the insertion of a customer s card The MX 4000W is easy to use easy to service and is able to support customer s needs This manual is designed
6. e not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment NOTE This equipment has been tested and found to comply with the limits for a Class digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense G HYOSUNG MAUTILUS HYOSUNG INC MX 4000W Installation Manual Description of Precaution Symbols Risk Of Electric Shock Do not remove cover Only a maintenance engineer should open the cover e To avoid risk of electric shock do not touch e Make sure to turn off the power before servicing the equipment Moving The equipment is heavy Make sure at least 2 people lift or move the equipment Do not attempt to move the equipment alone You may be injured from dropping the heavy equipment Risk of Injury Always lock Push Plate before adding cash to cassette Refer to user manual for details Hot Surface e Do not touch the equipment when it is o
7. ill need to prepare the hardware e g shank to mount the mounting frame bracket Due to the variety of walls and their composition Nautilus Hyosung can not supply the hardware you may require The maximum shank diameter of the mounting hardware is 1 5 inch e It is the owner s responsibility to ensure that the machine is anchored securely Personal injury and equipment damage can occur if the machine is not properly secured 1 Unlock the key lock and press the Push End button to open the front door 2 Take out the cash dispenser unit by pulling it out and separate the mounting frame bracket Unfasten the screws 6ea 3 Attach the mounting frame bracket separated in the previous step on the wall using the hardware prepared in advance It is recommended that the bottom of the mounting frame bracket is 1m 39 37inch off the floor to help meet ADA guidelines 4 Hang the ATM on the mounting frame bracket and fasten the screws 6ea unfastened in the step of 2 5 To take the power cable and LAN cable out of the ATM separate the bracket on the bottom inside the ATM After taking them out place the bracket on its original position SP HYOSUNG NAUTILUS HYOSUNG INC MX 4000W Installation Manual Fig 3 Attaching the mounting frame bracket separated from the ATM Gi HYOSUNG MAUTILUS HYOSUNG INC MX 4000W Installation Manual Fig 4 Attaching the mounting frame bracket using the hardware e g shank studs and so on Gi
8. n The equipment can get extremely hot and may cause a burn Make sure to close the cover before running the equipment Risk of Injury Turn off the machine before performing any service work Use caution to avoid injury Handling Heavy Equipment You may be injured if machine is dropped or mishandled Use caution when moving the machine to avoid injury Risk of Injury Use caution when operating the push plate to avoid injury The covers should be locked to avoid injury e Refer to operating manual before installing the cassette Gi HYOSUNG NAUTILUS HYOSUNG INC MX 4000W Installation Manual gt Fire Hazard e Place the equipment in an area away from any combustible materials e The equipment may catch on fire from overheating or short circuit of the powe supply unit Disassembly Do not disassemble or modify the equipment unless you are a certified engineer Contact the service center for maintenance adjustments and repairs e Improper disassembly may cause fire or electrical shock Unplug the Equipment Stop using the equipment immediately if it smokes emits an unusual smell makes abnormal sounds or if liquids or other foreign materials enter the equipment e If the above mentioned abnormalities occur immediately turn off the power unplug the equipment and contact the service center e If you ignore these symptoms the equipment may catch on fire or cause electric shock Fall down
9. o MX 4000W ATMs 760mm 29 92 840mm 33 07 NOTE 1 The dimensions of a boxed MX 4000W ATM are 620x770x425mm 24 41x30 31x16 73inch HXWXD 2 Approximate weight of each MX 4000W ATM is 99 21 110 23lb 45 50 Kg Actual weight will vary depending on ATM component configuration SP HYOSUNG NAUTILUS HYOSUNG INC MX 4000W Installation Manual System Installation Unpacking 1 Cut the straps that are fastened around the box with a knife See Fig 1 below Be careful when cutting the straps 2 Use an appropriate tool to remove the nails from the palette See Fig 2 below 3 Remove the lid then box from the top Do not discard the packaging materials until you have verified any shipping damage claim Contact your distributor immediately if you see any shipping damage Store the box in a safe place to re use or discard of appropriately 4 Verify the contents carefully with the packing list to be sure all items listed are included Notify your distributor of any shortages Fig 1 Fig 2 CAUTION In order to move the machine and place it in a proper location you should seek the help of professionals trained in moving heavy equipment SP HYOSUNG NAUTILUS HYOSUNG INC MX 4000W Installation Manual Physical Installation Wall Mounting To install MX 4000W ATM perform the following steps referring to the picture in the following pages NOTE e Prior to the installation you w