1.    2   INPUTS     1  0  1  2     3 30 VDC from Proximity switches  Encoders     Potential free contacts  Limit switches etc   SENSOR SUPPLY   In built 12 VDC  410    30 mA  INPUT SPEED   1  30 Hz   2  2 5 kHz   CONFIGURATION LOCK   via rear terminals   RESET   1  On front panel    2  Remote reset   via rear terminals    MEMORY RETENTION   10 years   SUPPLY VOLTAGE   90 to 270 VAC DC   50 60 Hz   OPERATING TEMP    Operating  0   50  C   Storage  0 to 50  C  HUMIDITY   95  RH   HOUSING   Flame retardant plastic   WEIGHT   250 gms     PANEL DIMENSIONS dimensions in mm     k       96     gt 1    Panel i                                           Description Terminal  Short to select NPN sensor 1 2  Short to select PNP sensor 2 3  Count input 2   12V supply 4  COM  GND  6  Reset input 5 6  Short to Filter input noise 6 7  Short to enter configuration 9 10  Live   Neutral L  N  INPUT CONNECTIONS     PNP proximity sensor       NOTE  For PNP sensor input  short terminals 2  amp  3     NPN proximity sensor       sen      cee EST GOM  Short 1 amp 2  NOTE  For NPN sensor input  short terminals 1  amp  2     scsi free contact    CNT  i 412V  RST COM    Short 2 amp 3  NOTE  Short terminals 2  amp  3     pae    123     k   92    gt  Sensor color codes      Red    12V  Green   CNT  Black   GND     Baer Brown    12V  Black   CNT  Blue   GND     TERMINAL CONNECTION    SENSOR  SELECTION    NPN   PNP    Short to filter  input noise   12V RST com FILTER    CONFIG  i          NOTE        In some a
2. OPERATING INSTRUCTIONS  RC102C       Please maintain these instructions and  review them prior to using the unit     awarniea    1  This unit is panel mounted type with its  output terminals getting connected to the  host equipment  Such equipment shall also  comply with basic EMI EMC and safety  requirements like BSEN 61326 1 and  BSEN 61010 respectively    2  To avoid electric shock  power supply of the  unit should be kept off while wiring  Wiring  should be done strictly as per the terminal  layout  given in the manual    3  Use lugged terminals to meet M3 5 screws    4  The unit does not have a built in fuse   External fuse with a rating of 275 VAC 1A is  recommended     ACaution    1  This unitis notintended for outdoor use    2  The power connection cable must have a  cross section of atleast 1mm    and insulation  capacity of atleast 1 5kV    3  The output connections must not be loaded  beyond the specified values range    4  Avoid inflow of dust and contact of conductive  material with the internal circuitry of the unit    5  The unit must not operate in presence of  heating sources  caustic vapors  oil  steam   vibration orimpactetc    6  Use clean soaked cloth cleaning     SPECIFICATIONS   DISPLAY  Type  7 segment LED  Height  0 5      Counter  6 digits  Rate  4 digits   RANGE  Counter  9999 99  99999 9  amp  999999   Rate  Auto ranging  4 00 to 9999 RPM    ACCURACY  Rate  0 05      2 count         SCALE FACTOR    Programmable from 0 00001 to 9 99999x10     n    3
3. no 9  amp  10   3  Turn power on     TO READ SCALE FACTOR   RESOLUTION  amp  SPEED    NAME    DESCRIPTION    KEY PRESS     MOMENTARY  DISPLAY    Scale Factor   Mantissa     Scale Factor   Exponent     Totaliser Least  Count    Maximum Input  Speed          NOTE  Maximum display time is 3 sec  If the key  is pressed again within 3 sec of previous key  press  display shows next parameter  otherwise  it shows rate or total as per selection        TYPICAL APPLICATION    Objective  To display  a  The total length of cord  in  meters  that has passed over the measuring  wheel   b  The delivery rate of cord  meters   minute     Data available    The proximity switch generates 1 pulse    revolution of the measuring wheel  The diameter  of the wheel is 10cm        Cae a TOTAL    g RC102    selec    Switch  Calculations  Circumference of the wheel   3 14285 x 0 1    0 314285m     Therefore the length of rope delivered per  revolution is 0 314285m    Since the proximity switch gives one pulse per  revolution  the display should increment by  0 314285 for every pulse  Therefore  scale factor   0 314285    Set scale factor mantissa   3 14285  amp  exponent    10     The RC102C will show rate in meters   minute  amp   total in meters     Example 2  If 60 PPR encoder is fitted instead of  proximity    Length of rope delivered per revolution is  0 314285m    Number of pulses per revolution   60    Length of rope delivered   pulse   0 314285   60    0 005238m    The display should increment b
4. on unit will go into configuration  setting mode  To quit configuration setting mode   1  Turn power off   2  Remove link between terminal nos 9  amp  10   3  Turn power on     Document name  Operating   0809   RC102C   ver3 OP191 V03  Page 1 of 2     _     CONFIGURATION SCHEME    To enter configuration short terminals 9  amp  10  and turn the power on     Configure the unit as per the instructions below     1  To select scale factor mantissa  KEY PRESS  DISPLAY DESCRIPTION    E facto Set between  E i0000    0 00001 to 9 99999  as described below   The blinking digit increments by 1 for every press  of the Q key  amp  rolls over from 9 to 0  The blinking  digit shifts to next digit  right  for every press of       key  Using these keys user can set the required  value     2  Press R T   key to select scale  factor exponent   cale factor    m   exponent      U   Press Q    Press  a  Press  a  Press    a    Press    a    3  Press R T    key to select  totaliser resolution    resolution    10    100    10     0 001    10     0 01          10      0 1      Least count   1    Least count   0 1    Press Q    Least count   0 01  Press Q             4  Press R T    key to select max   input frequency    pax Fed E 2500  F Fast peed  frequency  maximum 2500 hz   Slow speed  Press Q  2 38 j     maximum 30 hz    5  Press R T   key to complete  setting  display will go to step 1   scale factor mantissa setting    To quit configuration   1  Turn power off   2  Remove link between terminal 
5. pplications  the proximity sensors  may pick up high frequency noise form nearby  switching circuits like AC   DC drive  Due to  this the counter may show erroneous reading   Short terminals 6 7 for RC102C as shown in  figure above  to filter out high frequency  spurious pulses by limiting the input frequency to  about 200Hz  1200 RPM               RATE OR TOTAL DISPLAY MODE  a    The RC102C toggles between RATE display and  TOTAL display at the momentary press of R T     key   In rate mode RATE LED glows  amp  in totaliser mode  TOTAL LED glows        selec te oww             RATE  press          key momentary           23 456   DO    at Rc102             TOTAL    RESETTING THE RC102C    A  By front key  Press R T   key continuously for 3  sec  The totaliser resets to zero and starts counting  again  and the display shows the rate or total as per  selection    B  Remote reset    The RC102C can be reset from a remote push  button as shown in the figure below     Reset by potential free switch    CNT  12V RST COM    INITIALISATION    Switch off the power  Short terminal no  9  amp 10  Press  key    at the time of turning the power on  The key  must continue to remain pressed for another 3 sec   When this sequence is correctly performed  the unit  initialises and all parameters are set to factory  settings    Scale factor changes to 1  mantissa   1 0000  amp   exponent   10   1   Resolution   1  Maximum input  frequency   2500 Hz  Totaliser resets to 0        After initialisati
6. y 0 005238 for  every pulse  Therefore  scale factor   5 23800 x  10     Set scale factor mantissa   5 23800  amp  exponent    10  for the required display         Specifications subject to change as development  is a continuous process      Selec Controls Pvt  Ltd   India    Formerly Selectron Process Controls Pvt  Ltd    Tel 91 22 28476443  Fax 91 22 28471733   Website  www selecindia com   E  mail  sales   selecindia com        Document name  Operating   0809   RC102C   ver3 OP191 V03  Page 2 of 2     
    