Home

Manual - ETS

image

Contents

1. epe epe puto 8 18 GHZ 6 ed rt tege eret 8 40 GHz Models essseeeeeeeeenneen eene enn rennen nnns 8 12 4 GHz Model 8 EMCenter Modular RF Platform Required 9 EMSwitch Remote Relay 10 Standard Gonfig ratiOn cae ccce recepto o cet epe ree 10 Optlonial Itemss tee Ae 10 2 0 Maintenance eere nennen 11 Maintenance of Fiber Optics If 11 Service Procedures ee ete hts 12 Contacting ETS Lindgren sseeeennn 12 Sending a Component for 12 3 0 Specifications erae scutteddecehcceds 13 Performance Specifications 13 Lifetime Relays sese nnne 14 Electrical Specifications esee 14 Physical Specifications etin RR HERES 15 Environmental Specifications enne 15 4 0 EMSwitch Card Controls and Connectors 17 Relay Number and Contact Definitions Interlock ir citt t rrr Pme 5 0 EMSwitch Plug In Card Installation 19 Plug In Card Installation 6 0 EMSwitch Remote Relay Front and Back Panel Connectors ets lindgren com Set Up RS 232
2. 2 OR x y OR x Returns the software version number VERSION HW 2 OR x y OR x Returns the hardware version number ets lindgren com EMSwitch Command Set COMMAND SET MODEL SPECIFIC 7001 001 7001 002 7001 011 7001 012 7001 021 Description Command Reply Returns the status of internal relay 1 2 3 or 4 NO or NC INT_RELAY_A INT_RELAY_B INT RELAY C INT RELAY D Sets the internal relay A B C or D to NO NO or NC INT RELAY A NO INT RELAY B NO INT RELAY C NO INT RELAY D NO Sets the internal relay A B C or D to NC NO or NC INT RELAY A NC INT RELAY B NC INT RELAY C NC INT RELAY D NC Returns the analog temperature of the internal 100 relay A B C or D Three ASCII INT TEMPERATURE A characters with INT TEMPERATURE B temperature in INT TEMPERATURE C degrees Gellys INT TEMPERATURE D Set switch 2 of EMSwitch Remote Relay 1 to OK position 3 N11RELAY 2 3 Set switch 2 of EMSwitch Remote Relay 2 to OK position 4 N12RELAY 2 4 34 EMSwitch Command Set ets lindgren com Description Command Reply Get position of switch 2 of EMSwitch Remote Relay 1 N11RELAY 2 One of the following 1 2 3 4 5 6 Get position of switch 3 of EMSwitch Remote One of the following Relay 2 2 3 4 5 6 N12RELAY 3 Set switch type of switch 3 of EMSwitch Remote OK Relay 2 to 1 to 2 1 to 3 1 to 4 1 to 5 or 1 to 6
3. 5 or 6 outputs To connect external relays you must use the mating connector set included with the remote relay ets lindgren com EMSwitch Remote Relay 21 The relay x drive connectors on the back panel of the remote relay will switch the relays into position e Fora24V relay connect pin 1 24 V DC output to the Common of the relay power terminals e Fora 12V relay connect pin 2 12 V DC output to the Common of the relay power terminals Connect pin 3 8 to the power terminals 1 6 of the relay The number of power terminals to connect depends on the type of relay you use For example a 1 6 relay requires all of the pins and a 1 3 relay requires three pins Readback Function The relay x readback connectors on the back panel remote relay can verify if the external relay is set into position 1 Connect pin 1 3v3 out to the indicator common of the relay 2 Connect pin 2 to the first indicator of the relay 3 Connect pin 3 to the second indicator continue until complete The number of indicator terminals to connect depends on the type of relay you use Pin 8 is not in use Set the readback function on or off in the EMCenter Modular RF Platform depending on the number of relay s with readback function that you use 22 EMSwitch Remote Relay ets lindgren com Set Up RS 232 Address You can connect up to four external switch boxes to one EMCenter Interconnect the switch boxes with straight RS 232 ca
4. Address iere eee eR HIR Regens 23 T O Operation oic iere ss eet ctore cnet taandas iniae 25 Powering On and Off EMCenter ssssssseeeeeem m 25 Ido mo M 25 Power Off 3n i nie in n HE Hie 27 Manual Control of EMSwitch sessseeeeeeeenen nn 28 Safety Interlock 29 Relay Errors ire pre rer eere n eue serere pero erba rage 30 8 0 EMSwitch Command Set esee 31 Examples oreet De teet eei LN sese M rs ses err 31 Example 1 Request Software 31 Example 2 Set Internal 31 Example 3 Set External 32 Remote Commands creme Ee eq ne as 33 Command Set Common to All EMSwitch Models 33 Command Set Model Specific 7001 001 7001 002 7001 011 700170125 7001 021 sn eene Ue HERR HERES 34 Command Set Model Specific 7001 003 7001 005 7001 013 7001 015 Error Codes Power Handling i nseni certae d a gen 39 MAY aki 41 Appendix A Warranty eren 43 Scope and Duration of Warranties 43 Warranty Excl sions ertet tne tr DH re Peine Buyer s Re
5. N12RELAYTYPE 3 2 N12RELAYTYPE_3 3 N12RELAYTYPE_3 4 N12RELAYTYPE 3 5 N12RELAYTYPE 3 6 Get switch type of switch 3 of EMSwitch Remote One of the following Relay 2 2 3 4 5 6 N12RELAYTYPE 2 Disable readback to switch 3 of EMSwitch Remote OK Relay 2 N12READBACK 3 0 Enable readback to switch 3 of EMSwitch Remote OK Relay 2 N12READBACK 3 1 Get readback status to switch 3 of EMSwitch Remote Relay 2 N12READBACK 3 0 disabled OR 1 enabled ets lindgren com EMSwitch Command Set 35 COMMAND SET MODEL SPECIFIC 7001 003 7001 005 7001 013 7001 015 Description Command Reply Returns status of internal relay A or B INT RELAY A INT RELAY B One of the following 1 2 3 4 5 6 Sets internal relay A or B INT RELAY A 1 INT RELAY A 2 INT RELAY A 3 INT RELAY A 4 INT RELAY A 5 INT RELAY A 6 One of the following 1 2 3 4 5 6 36 EMSwitch Command Set ets lindgren com Error Codes Error Code Description ERROR 201 Switch error while trying to switch to NC internal relays only ERROR 202 Switch error while trying to switch to NO internal relays only ERROR 203 Temperature error NC internal relays only ERROR 204 Temperature error NO internal relays only ERROR 205 Interlock error internal relays only ERROR 206 Error Switch A ERROR 207 Error Switch B ERROR 208 Error Switch ERROR 20
6. SENDING A COMPONENT FOR SERVICE 1 Contact ETS Lindgren Customer Service to obtain a Service Request Order SRO 2 Briefly describe the problem in writing Give details regarding the observed symptom s or error codes and whether the problem is constant or intermittent in nature Please include the date s the service representative you spoke with and the nature of the conversation Include the serial number of the item being returned 3 Package the system or component carefully If possible use the original packing materials or carrying case to return a system or system component to ETS Lindgren 12 Maintenance ets lindgren com 3 0 Specifications Note The first switch on each EMSwitch card can be used as a true interlock switch Performance Specifications Number of Frequency RF Switching Capacity Relays Band 7001 001 2x SPDT DC to 3 GHz 240 W 7001 002 4x SPDT 310 8 GHz 150W 18 GHz 7001 003 2x SP6T 8 to 12 4 GHz 120W 7001 005 1XSP6T 12 4 to 18 GHz 100W 7001 011 2x SPDT DC to 6 GHz 80 W 7001 012 4x SPDT 6 to 12 4 GHz 60 W 12 4 to 18 GHz 50 W 18 to 26 5 GHz 20 W 26 5 to 40 GHz 10 W 40 GHz 7001 013 2x SP6T DC to 6 GHz 40 W 7001 015 1xSP6T 12 4 to 18 GHz 25 W 18 to 26 5 GHz 15W 26 5 to 40 GHz 5 W 7001 021 1x SPDT 12 4 GHz DC to 1 GHz 700 W 1 to 2 GHz 500 W 2 to 3 GHz 400 W 3 to 8 GHz 250 W 8 to 12 4 GHz 200 W ets lindgren com
7. Specifications Lifetime Relays e SPDT relays SMA or 2 92mm 10 000 000 cycles e SP6T relay SMA 5 000 000 cycles e SP6T relay 2 92mm 2 000 000 cycles e N type relay 1 000 000 cycles Electrical Specifications All EMSwitch RF Switch Plug in Cards perform to the following electrical specifications e Supply Voltage Volts Through EMCenter Note The supply voltage for the Model 7001 004 Remote Relay is 230 VAC e Power Consumption Max Watts 30 W 14 Specifications ets lindgren com Physical Specifications Exterior RF Remote Control Dimension Connectors External Relays 7001 001 One slot 7001 002 SMA type 7001 003 Two slots 7001 005 One slot BNC type 7001 011 One slot 7001 012 Fiber optic link k type 2 92 mm 7001 013 Two slots 7001 015 7001 021 One slot N type 7001 004 2U x 250 mm x SMA type Hx W x D 482 6 mm 2U x 9 8 in x 19 in Environmental Specifications All EMSwitch cards perform to the following environmental specifications e Temperature Range 0 C to 40 C 32 F to 104 F e Relative Humidity 10 to 90 non condensing ets lindgren com Specifications 15 This page intentionally left blank 16 Specifications ets lindgren com 4 0 EMSwitch Card Controls and Connectors provided in Safety Information on page v CAUTION Before placing into operation follow the information Relay Number and Contact
8. will display ISwitch 7001 001 EMSWIEIT TOO 021 EMSense 7007 001 No probe EMControl 7006 001 358 9 100 0 cm iSense 7007 002 Standby Press to start 30 000 000 MHz RF OFF Sample EMCenter Home Screen 26 Operation ets lindgren com POWER OFF 1 Press the Off button located on the EMCenter screen EMPower 7002 001 i ld EMSwitch 7001 001 EMSwitch 7001 021 EMSense 7007 001 EMControl 7006 00 EMSense 7007 002 Standby Press to start 30 000 000 MHz RF OFF Press OK to switch off the system The standby light located on the front panel of the EMCenter will flash and then will illuminate steadily Note When the EMCenter is in standby mode touch the screen anywhere to reboot Turn the power switch located on the back panel of the EMCenter to the off position Remove the power cord from the power connector on the back panel of the EMCenter Remove the interlock jack from the interlock connector on the back panel of the EMCenter ets lindgren com Operation 27 Manual Control of EMSwitch To change relay position settings on the Home screen press the status box to the right of the slot number for the installed EMSwitch plug in card This will display the following switch screen switch A Home switch B Back Info Ext Box1 Ext Box2 Ext Box3 Ext Box4 Config Sample Switch Screen Com Common NO Normally Open NC Normally Closed Press a switch butt
9. 9 Error external card ERROR 210 Error no external card connected ERROR 211 Error status unknown ERROR 215 Error out of config ets lindgren com EMSwitch Command Set 37 This page intentionally left blank 38 EMSwitch Command Set ets lindgren com 9 0 Typical Data Power Handling The RF power rating is the capability of handling RF power CW power through closed contacts The RF power should be removed turned off before switching the relay Power ratings assume the following specifications see the power handling data chart on page 40 Unity VSWR matched load e Room temperature 25 C 77 F e Sea level pressure 14 7 psi e Cold switching Changes to these specifications require power derating see the VSWR data chart on page 41 ets lindgren com Typical Data 39 ets lindgren com zH9 A9N3n0333 001 0l Lo L00 INN 21048 peog od AWS WIN OWS AWS e z 5 1090 Lads spem 9NILYY YIMOd 39 VH3AV Typical Data 40 VSWR The average power input must be reduced for load VSWR above 1 1 ets lindgren com YOLIVA ONILVYAG 0 1 V S W R Typical Data 41 This page intentionally left blank 42 Typical Data ets lindgren com Appendix A Warranty Scope and Duration of Warranties Seller warrants to Buyer that the Products to be delivered hereunder will be 1 free from defects in material manufacturing work
10. Definitions 7001 001 7001 002 7001 011 7001 012 Relay number Indicated below each relay A to D Common The center SMA connector of each relay labeled COM Normally Open The left SMA connector of each relay labeled NO Normally Closed The right SMA connector of each relay labeled NC 7001 003 7001 005 7001 013 7001 015 Common The center connector the six contacts are labeled J1 to J6 7001 021 Common The center N connector labeled COM Normally Open The bottom N connector labeled NO Normally Closed The top N connector labeled NC ets lindgren com EMSwitch Card Controls and Connectors Interlock The interlock connector provides two floating contacts which require shorting for the first relay If the interlock is open the first relay will illuminate red on the EMCenter Modular RF Platform screen and the relay cannot be used Use the supplied connector to wire to the emergency switch of your site Connect the two pins of the connector 18 EMSwitch Card Controls and Connectors ets lindgren com 5 0 EMSwitch Plug In Card Installation CAUTION Before connecting any components follow the information provided in Safety Information on page v ONLY with the EMCenter Do not use the card in Q CAUTION The EMSwitch card is designed to be used combination with any other system Plug In Card Installation Note D
11. EMSwitch RF Switch Plug In Card User Manual Model 7001 001 Model 7001 003 Model 7001 002 not all models shown WETS gt LINDGREN An ESCO Technologies Company ETS Lindgren Inc reserves the right to make changes to any product described herein in order to improve function design or for any other reason Nothing contained herein shall constitute ETS Lindgren Inc assuming any liability whatsoever arising out of the application or use of any product or circuit described herein ETS Lindgren Inc does not convey any license under its patent rights or the rights of others Copyright 2014 2015 by ETS Lindgren Inc All Rights Reserved No part of this document may be copied by any means without written permission from ETS Lindgren Inc Trademarks used in this document The ETS Lindgren logo is a registered trademark and EMCenter EMSwitch TILE and EMQuest are trademarks of ETS Lindgren Inc Revision Record MANUAL EMSWITCH Part 399343 Rev C Revision Description Date A Initial Release June 2014 B Updated EMCenter models June 2014 C Added Model 7001 005 updated July 2015 EMSwitch Remote Relay ets lindgren com Table of Contents Notes Cautions and 5 V Safety Information ssssssssssseeeeenenneen ennemi V 1 0 Introduction irae 7 EMSwitch Models
12. bles The DIP switches on the back panel of the EMCenter allow you to set the individual addresses DIP Switch EMSwitch Remote Relay Address 1 2 3 On On On Address 1 Off On On Address 2 On Off On Address 3 Off Off On Address 4 ets lindgren com EMSwitch Remote Relay 23 This page intentionally left blank 24 EMSwitch Remote Relay ets lindgren com 7 0 Operation CAUTION Before placing into operation follow the information provided in Safety Information on page v CAUTION Prior to operation verify that the mains voltage is within the operating range of the equipment Powering On and Off EMCenter Note For information on using the EMCenter touchscreen see the EMCenter Modular RF Platform User Manual O POWER ON Note Verify all cards are installed correctly in the EMCenter Verify that the EMSwitch RF Switch Plug in Card safety relay interlock connection is closed For more information see page 29 Plug the power cord from the mains inlet on the back panel of the EMCenter into a power outlet Plug the interlock jack into the interlock connector on the back panel of the EMCenter gt ps Q Turn the power switch located on the back panel of the EMCenter to the on position ets lindgren com Operation 25 5 Touch anywhere on the EMCenter screen It will take approximately 20 seconds to boot The Information screen will flash and then the Home screen
13. e Rules of the American Arbitration Association and judgment upon the award rendered by the Arbitrator may be entered in either the Federal District Court for the Western District of Texas or the State District Court in Austin Texas all of the parties hereto consenting to personal jurisdiction of the venue of such court and hereby waive the right to demand a jury trial under any of these actions 46 Warranty ets lindgren com Appendix B EC Declaration of Conformity ETS Lindgren Inc declares these products to be in conformity with the following standards following the provisions of EMC Directive 2004 108 EC EMSwitch RF Switch Plug In Card Emission EN 61326 1 2006 Class B Electrical equipment for measurement control and laboratory use Immunity EN 61326 1 2006 Industrial level performance criteria A Electrical equipment for measurement control and laboratory use Technical Construction Files are available upon request ets lindgren com EC Declaration of Conformity 47
14. failure of Buyer to prepare the site or provide an operating environmental condition in compliance with any applicable instructions or recommendations of Seller 3 absence of any product component or accessory recommended by Seller but omitted at Buyer s direction 4 any design specification or instruction furnished by Buyer its employees agents or contractors 5b any alteration of the product by persons other than Seller 6 combining Seller s product with any product furnished by others 7 combining incompatible products of Seller 8 interference with the radio frequency fields due to conditions or causes outside the product as furnished by Seller 9 improper or extraordinary use of the product or failure to comply with any applicable instructions or recommendations of Seller including maintenance calibration and cleaning procedures and intervals or 10 acts of God acts of civil or military authority fires floods strikes or other labor disturbances war riot or any other causes beyond the reasonable control of Seller This warranty does not include 1 batteries 2 cables 3 gasket 4 fingerstock or any item that is designed to be consumable Seller does not warranty products of others which are not included in Seller s published price lists 44 Warranty ets lindgren com Buyer s Remedies If Seller determines that any product fails to meet any warranty during the applicable warranty period Seller shall co
15. for additional information 20 EMSwitch Plug In Card Installation ets lindgren com 6 0 EMSwitch Remote Relay CAUTION Before placing into operation follow the information provided in Safety Information on page v For applications that require to switch higher power signals gt 700 Watts it is not possible to use internal relays of the switch cards in those cases special dedicated relays are needed in the test setup For these external relays EMSwitch Model 7001 004 Remote Relay which is capable of driving two external relays is available Model 7001 004 can drive any relay with a supply voltage of 12V 24V or 28V and from SPDT to SP6T For each relay a driver current of 0 5A is available or 1A if only one relay is connected The type of relay and the usage of indicator contacts can be configured in software The connection for relay 1 and relay 2 are identical Front and Back Panel Connectors The front panel includes a key switch and an LED If the EMSwitch Remote Relay is connected to a 220 V AC power supply and the on off switch on the back panel is set to the I position you can power on the remote relay by turning the key clockwise The LED will illuminate The Remote Relay must be connected to a 220 V AC power supply via the mains lead connected at the AC inlet on the back panel Relays You can connect four relays to the remote relay It is possible to connect relays with 1 input and 2 3 4
16. high field strengths when entering the test chamber Relay Errors The EMSwitch plug in card checks for the following error conditions of the internal relays 1 Over temperature A temperature sensor close to each relay checks for excessive heating of the relay A high temperature error will display if the relay temperature exceeds 85 C 185 F 2 Switching error Each internal relay has a set of control contacts which are used to check if a relay has changed position A switching error message will appear if this check fails 3 Interlock open for safety interlock relay When the interlock of relay A is opened this will result in a safety interlock open error 30 Operation ets lindgren com 8 0 EMSwitch Command Set See Hemote Commands on page 33 for the commands that can be used with the EMSwitch RF Switch Plug in Card Each command must include a device ID number as the prefix see the EMCenter Modular RF Platform User Manual for complete information on device ID numbers e Terminate each command with a line feed LF shown as n in command syntax e Each response from the device is terminated with a line feed LF shown as n in command syntax Examples EXAMPLE 1 REQUEST SOFTWARE VERSION To request the software version of the EMSwitch card with device ID number 1 S1 VERSION SW EXAMPLE 2 SET INTERNAL RELAY To set the internal relay A from the EMSwitch card with device ID number 1 to nor
17. information about EMCenter see page 9 The first relay of each EMSwitch card can be used as a standard relay or as a safety interlock relay When being used as a safety interlock relay the RF input signal to the RF amplifier can be switched off to prevent personnel from being subjected to high RF fields The RF interlock input can for example be connected to a switch mounted on the entrance door of the test chamber EMSwitch is fully supported by ETS Lindgren TILE Totally Integrated Laboratory Environment ETS Lindgren EMQuest Data Acquisition and Analysis Software and other test automation software packages Contact ETS Lindgren for additional information ets lindgren com Introduction EMSwitch Models EMSwitch cards switch RF signals up to 40 GHz depending on the model with powers up to 240 W 3 GHz directly or any RF power switches indirectly When high power RF amplifiers are used in a test system the EMSwitch card can be connected to an optional EMSwitch Remote Relay Module For more information see page 10 The following models of the EMSwitch card are available Note The EMCenter supports any installed combination of EMSwitch cards 18 GHz MODELS e 7001 001 Two SPDT coaxial relays e 7001 002 Four SPDT coaxial relays e 7001 003 Two coaxial relays e 7001 005 coaxial relay 40 GHz MODELS e 7001 011 Two SPDT coaxial relays e 7001 012 Four SPDT coaxial relay
18. mally open S1 1NT RELAY A NO ets lindgren com EMSwitch Command Set 31 EXAMPLE 3 SET EXTERNAL RELAY To set the external relay 3 from the EMSwitch Remote Relay with address 4 connected to the EMSwitch card at slot 2 position 5 S2 N14RELAY 3 5 S Device character of EMSwitch card 2 Board number of EMSwitch Indicates EMSwitch card to pass message to external interface 4 Address of EMSwitch Remote Relay configurable with DIP switches RELAY Message to switch relay 3 Number of switch on EMSwitch Remote Relay _ Separator 5 Instruction to put switch in position 5 Capes EMCenter 3 EMSwitch Module EMSwitch Module 32 EMSwitch Command Set EMSwitchBox EMSwitchBox P EMSwitchBox EMSwitchBox ets lindgren com Remote Commands Note If you receive an error code in response to a command see page 37 for a list of error codes COMMAND SET COMMON TO ALL EMSwitcH MODELS Command Description Reply IDN Model Version X Y Z Request device identification Example ETS Lindgren EMSwitch 7001 003 3 5 10 LOCAL Return to local mode the local display is used to set items RESET n Reset clear the current error ID NUMBER Request unique identifier number VERSION SW
19. manship and title and 2 conform to the Seller s applicable product descriptions and specifications if any contained in or attached to Seller s quotation If no product descriptions or specifications are contained in or attached to the quotation Seller s applicable product descriptions and specifications in effect on the date of shipment shall apply The criteria for all testing shall be Seller s applicable product specifications utilizing factory specified calibration and test procedures and instruments All product warranties except the warranty of title and all remedies for warranty failures are limited to three years Product Warranted Duration of Warranty Period EMSwitch RF Switch Plug in Card 3 Years Any product or part furnished to Buyer during the warranty period to correct a warranty failure shall be warranted to the extent of the unexpired term of the warranty applicable to the repaired or replaced product The warranty period shall commence on the date the product is delivered to Buyer however if Seller assembles the product or provides technical direction of such assembly the warranty period for such product shall commence on the date the assembly of the product is complete Notwithstanding the foregoing in the event that the assembly is delayed for a total of thirty 30 days or more from the date of delivery for any reason or reasons for which Seller is not responsible the warranty period for such
20. medies Appendix B EC Declaration of Conformity iv ets lindgren com Notes Cautions and Warnings Note Denotes helpful information intended to provide tips for better use of the product could result in minor personal injury and or property damage Included text gives proper procedures Warning Denotes a hazard Failure to follow instructions could result in SEVERE personal injury and or property damage Included text gives proper procedures Caution Denotes a hazard Failure to follow instructions Safety Information High Voltage Indicates presence of hazardous voltage Unsafe practice could result severe personal injury or OR death Protective Earth Ground Safety Ground Indicates protective earth terminal You should provide uninterruptible safety earth ground from the main power source to the product input wiring terminals power cord or supplied power cord set Laser Warning Denotes a laser class 1M is part of the operating system of the device gt Class 1M ets lindgren com This page intentionally left blank vi ets lindgren com 1 0 Introduction The ETS Lindgren EMSwitch RF Switch Plug in Card is a general purpose multi channel switch matrix used to switch the RF path of equipment for RF measurement applications including immunity emissions and wireless measurements EMSwitch is designed for use with the EMCenter Modular RF Platform for more
21. on Optional Items e Model 7001 004 Remote Relay 10 Introduction ets lindgren com 2 0 Maintenance lt CAUTION Before performing any maintenance follow the information provided in Safety Information on page v WARNING Maintenance of the EMSwitch card is limited to external components such as cables or connectors If you have any questions concerning maintenance contact ETS Lindgren gt Customer Service Maintenance of Fiber Optics If Used Fiber optic connectors and cables can be damaged from airborne particles humidity and moisture oils from the human body and debris from the connectors they plug into Always handle connectors and cables with care using the following guidelines CAUTION Before performing any maintenance disconnect the fiber optic cables from the unit and turn off power When disconnecting fiber optic cables apply the included dust caps to the ends to maintain their integrity Before connecting fiber optic cables clean the connector tips and in line connectors Before attaching in line connectors clean them with moisture free compressed air Failure to perform these tasks may result in damage to the fiber optic connectors or cables ets lindgren com Maintenance 11 Service Procedures CONTACTING ETS LINDGREN Note Please see www ets lindgren com for a list of ETS Lindgren offices including phone and email contact information
22. on switch A switch B and so on to toggle between NO and NC 28 Operation ets lindgren com Safety Interlock Relay Relay A on each EMSwitch plug in card can be used as a safety interlock relay As long as the connector is shorted by an external interlock switch the relay can be activated However as soon as the interlock circuit opens relay A will return to the idle position Note If you do not want to use this relay as a safety relay the connector must be shorted in order to use it as a standard relay When the safety interlock relay is activated the power supply to the first relay of the card will be interrupted fully hardware controlled causing the relay to switch to the normally open position The EMCenter will detect this interlock status and display a message For safety reasons the software is not able to overrule this interlock condition After the interlock has been closed again the relay will switch automatically to its original condition interlock error switch B Ext Box1 ExtBox2 Ext Box3 ExtBox4 Config Sample Interlock Error Screen ets lindgren com Operation 29 The interlock hardware is implemented in a redundant way for maximum safety The interlock relay can be used to interrupt the signal path between the signal generator and the power amplifier An interlock switch mounted on the door of the test chamber can be used to activate the safety relay preventing personnel from being subject to
23. product may at Seller s options commence on the thirtieth 30th day from the date such product is delivered to Buyer Buyer shall promptly inspect all products upon delivery No claims for shortages will be allowed unless shortages are reported to Seller in writing within ten 10 days after delivery No other claims against Seller will be allowed unless asserted in writing within thirty 30 days after delivery or assembly if the products are to be assembled by Seller or in the case of alleged breach of warranty within the applicable warranty period ets lindgren com Warranty 43 Warranty Exclusions Except as set forth in any applicable patent indemnity the foregoing warranties are exclusive and in lieu of all other warranties whether written oral express implied or statutory EXCEPT AS EXPRESSLY STATED ABOVE SELLER MAKES NO WARRANTY EXPRESS OR IMPLIED BY STATUTE OR OTHERWISE WHETHER OF MERCHANTABILITY OR FITNESS FOR ANY PARTICULAR PURPOSE OR USE OR OTHERWISE ON THE PRODUCTS OR ON ANY PARTS OR LABOR FURNISHED DURING THE SALE DELIVERY OR SERVICING OF THE PRODUCTS THERE ARE NO WARRANTIES WHICH EXTEND BEYOND THE DESCRIPTION ON THE FACE HEREOF Warranty coverage does not include any defect or performance deficiency including failure to conform to product descriptions or specifications which results in whole or in part from 1 negligent storage or handling of the product by Buyer its employees agents or contractors 2
24. remedies and Seller s sole liability for claims based on failure of the products to meet any warranty whether the claim is in contract warranty tort including negligence and strict liability or otherwise and however instituted and upon the expiration of the applicable warranty period all such liability shall terminate IN NO EVENT SHALL SELLER BE LIABLE TO BUYER FOR ANY SPECIAL INDIRECT INCIDENTAL OR CONSEQUENTIAL DAMAGES OF ANY KIND ARISING OUT OF OR ASA RESULT OF THE SALE DELIVERY NON DELIVERY SERVICING ASSEMBLING USE OR LOSS OF USE OF THE PRODUCTS OR ANY PART THEREOF OR FOR ANY CHARGES OR EXPENSES OF ANY NATURE INCURRED WITHOUT SELLER S WRITTEN CONSENT DESPITE ANY NEGLIGENCE ON BEHALF OF THE SELLER IN NO EVENT SHALL SELLER S LIABILITIES UNDER ANY CLAIM MADE BY BUYER EXCEED THE PURCHASE PRICE OF THE PRODUCT IN RESPECT OF WHICH DAMAGES ARE CLAIMED This agreement shall be construed in accordance with laws of the State of Texas In the event that any provision hereof shall violate any applicable statute ordinance or rule of law such provision shall be ineffective to the extent of such violation without invalidating any other provision hereof Any controversy or claim arising out of or relating to the sale delivery non delivery servicing assembling use or loss of use of the products or any part thereof or for any charges or expenses in connection therewith shall be settled in Austin Texas by arbitration in accordance with th
25. rrect any such failure by either at its option repairing adjusting or replacing without charge to Buyer any defective or nonconforming product or part or parts of the product Seller shall have the option to furnish either new or exchange replacement parts or assemblies Warranty service shall be performed at the Seller s factory or the Buyer s site at the sole discretion of the Seller Within the warranty period the Buyer shall be responsible for all transportation to the Seller s factory and the Seller shall be responsible for transportation of goods to the Buyer s site Within the contiguous 48 United States warranty service performed during the applicable warranty period will be performed without charge to Buyer during Seller s normal business hours After the warranty period service will be performed at Seller s prevailing service rates Subject to the availability of personnel after hours service is available upon request at an additional charge Outside the contiguous 48 United States travel and per diem expenses when required shall be the responsibility of the Buyer or End User whichever is applicable regardless of the warranty period The remedies set forth herein are conditioned upon Buyer promptly notifying Seller within the applicable warranty period of any defect or non conformance and making the product available for correction ets lindgren com Warranty 45 The preceding paragraphs set forth Buyer s exclusive
26. s e 7001 013 Two coaxial relays e 7001 015 coaxial relay 12 4 GHz MODEL e 7001 021 One SPDT coaxial relay 8 Introduction ets lindgren com EMCenter Modular RF Platform Required The EMCenter Modular RF Platform is required for operation and is sold separately EMCenter Front Panel Back Panel The EMCenter may be controlled from a computer using these software products e ETS Lindgren TILE Totally Integrated Laboratory Environment e ETS Lindgren EMQuest Data Acquisition and Analysis Software e Other test automation software Contact ETS Lindgren for ordering information ets lindgren com Introduction EMSwitch Remote Relay Optional The Model 7001 004 Remote Relay is an optional 19 inch 2U rack mountable device to control up to four external coax relays using the touchscreen on the EMCenter or with one of these software products e ETS Lindgren TILE Totally Integrated Laboratory Environment e ETS Lindgren EMQuest Data Acquisition and Analysis Software e Other test automation software It has an internal power supply to power 12 VDC 28 VDC relays For more information on the Remote Relay see page 21 Standard Configuration e EMSwitch RF Switch Plug in Card Interlock required for operation and is sold separately Contact Note The Model 7001 001 EMCenter Modular RF Platform is ETS Lindgren for ordering informati
27. ue to the width of the 7001 003 7001 005 7001 013 and 7001 015 EMSwitch cards two consecutive empty slots are required for installation 1 Determine in which empty slot in the EMCenter Modular RF Platform you want to install the EMSwitch RF Switch Plug in Card Looking at the back of the EMCenter the slots are numbered 1 through 7 from left to right 2 Remove the blank panel from the slot by removing the two screws at the top of the blank panel and the two screws at the bottom Remove two consecutive blank panels if you are installing the 7001 003 7001 005 7001 013 or 7001 015 EMSwitch card 3 Carefully insert the EMSwitch card into the slot s of the EMCenter Tighten the four screws 4 Turnon the EMCenter The EMCenter will automatically detect the newly installed EMSwitch card 5 Depending on the test setup requirements connect coaxial cables to the relay connections on the back panel of the EMCenter 6 Connect the EMCenter to a personal computer using USB RS 232 Ethernet or IEEE optional 7 Plug the interlock into the connector on the back of the EMCenter ets lindgren com EMSwitch Plug In Card Installation 19 The card installation is complete You can control EMSwitch through the EMCenter touchscreen with ETS Lindgren TILE Totally Integrated Laboratory Environment ETS Lindgren EMQuest Data Acquisition and Analysis Software and other test automation software packages Contact ETS Lindgren

Download Pdf Manuals