FX2N -16CCL-M CC-Link SYSTEM MASTER BLOCK HARDWARE
Contents
1. 625 kbps 2 5 Mbps 5 Mbps 0 set by rotary switch Maximum total cable length maximum transmission distance 1 200 m maximum Varies depending on the transmission speed Refer to USER S MANUAL Remote I O stations 7 maximum Each station occupies 32 I O points of the PLC Remote device stations 8 maximum The following condition must be satisfied 1xa 2xb 3xc 4xd lt 8 a Number of remote device stations occupying 1 station b Number of remote device stations occupying 2 stations c Number of remote device stations occupying 3 stations d Number of remote device stations occupying 4 stations Number of remote I O stations Number of remote device stations lt 15 Maximum number of I O points per system below shall be satisfied For the system configuration calculation refer to USER S MANUAL Connection is allowed as far as the following condition is satisfied Actual number of I O points of PLC Number of points occupied by special extension blocks Number of points occupied by FX2N 16CCL M 8 32 x Number of remote I O modules lt 256 FX2N FX2NC Series PLC or 128 FXiN Series PLC For the system configuration calculation refer to USER S MANUAL Remote I O station Remote I O 32 32 RX RY points Remote device station Remote I O 32 32 RX RY points Remote register 4 RWw points master station remote device station Remote register 4 RWr points remote device stati
2. cable dedicated CC Link cables OR dedicated CC Link high performance cables If both types of cables are used together normal data transmission cannot be guaranteed The shielded dedicated CC Link cable should go through the terminals SLD and FG in each module and both ends should be grounded Class D solid grounding The terminals SLD and FG are connected each other inside the module Master module Remote module Remote module Terminal ee ied ag i a ee Terminal resistor DB i DB DB resistor DG DG H DG SLD Dedicated CC Link cable SLD Dedicated CC Link cable SLD i i 3 SPECIFICATION 3 1 General Specification Dielectric strength 500V AC for 1 minute between the case and the PLC ground Other specification is equivalent to that of the PLC main unit 3 2 Performance Specification Wem Specification Applicable function Master station function The local station and standby master station functions are not provided CC Link version Ver 1 10 ee Selectable by rotary switch among 156 kbps 625 kbps 2 5 Mbps 5 Mbps 0 set by rotary switch Maximum total cable length maximum transmission distance 1 200 m maximum Varies depending on the transmission speed Refer to USER S MANUAL Remote I O stations 7 maximum Each station occupies 32 I
3. equipment you must satisfy yourself as to its suitability for your specific application Note s on the symbology used in this manual At various times through out this manual certain symbols will be used to highlight points of information which are intended to ensure the user s personal safety and protect the integrity of the equipment Whenever any of the following symbols are encountered its associated note must be read and understood Each of the symbols used will now be listed with a brief description of its meaning Hardware warnings A 1 Indicates that the identified danger WILL cause physical and property damage A 2 Indicates that the identified danger could POSSIBLY cause physical and property damage 1 INTRODUCTION 1 1 Associated Manuals Manual name Manual number Description FX2N 16CCL M JY992D93101 Describes programming and handling of the CC User s Manual sent separately Link master block FX2N 16CCL M k FX1S FX1N FX2N FX2NC JY992D88101 Explains the instructions in the FX1S FX1N FX2N Programming Manual II sent separately FX2Nc Series PLC Describes the contents related to the hardware such as specification wiring and mounting of the FX1N Series PLC Describes the contents related to the hardware such as specification wiring and mounting of the FX2N Series PLC Describes the contents related to the hardware ani es such as specification wiring and mounting of the P p FX2NC Series PLC yw FX2
4. error The SW LED indicator turns ON 8 to A Cannot be set because it is already used inside B to F Setting error The SW LED indicator turns ON Transmission Sets the transmission speed of the module Default setting at shipment 0 speed setting Number Setting contents switch 156 kbps 625 kbps 2 5 Mbps 5 Mbps 10 Mbps 5to9 Setting error The SW and L ERR LED indicators turn ON Condition Sets the operation condition Default setting at shipment All OFF setting switch Number Setting description Switch status N FF B RATE 156K 625K e i O zZ esz9SsSrez 2 SW1 to SW3 Unusable Always OFF I 1s l Keep Clear SW4 Input data status in data link faulty station HLD CLR SW5 to Unusable Always OFF ep 4 foe Terminal block Connects dedicated CC Link cables to enable data link For the connection method refer to Section 2 3 The terminals SLD and FG are connected inside ga vd 5q qS Extension Connects the PLC Next step extension Connects an extension equipment connector DIN rail mounting DIN46277 DIN rail mounting groove of 35 mm 1 38 in width groove 2 Installation and wiring A INSTALLATION PRECAUTIONS e Use the m
5. ADVANCED AND EVER APVANCINS MITSUBISHI ELECTRIC a MITSUBISHI PROGRAMMABLE CONTROLLERS CC 1 Link MELSEGP FX2N 16CCL M CC Link SYSTEM MASTER BLOCK HARDWARE MANUAL JY 992D93201A This manual contains text diagrams and explanations which will guide the reader in the correct installation and operation of the FX2N 16CCL M CC Link SYSTEM MASTER BLOCK It should be read and understood before attempting to install or use the unit Further information can be found in the FX series PLC hardware manuals Guidelines for the safety of the user and protection of the FX2N 16CCL M CC Link SYSTEM MASTER BLOCK e Ifin doubt at any stage during the installation of the FX2N 16CCL M CC Link SYSTEM MASTER BLOCK always consult a professional electrical engineer who is qualified and trained to the local and national standards If in doubt about the operation or use of the FX2N 16CCL M CC Link SYSTEM MASTER BLOCK please consult the nearest Mitsubishi Electric distributor e Under no circumstances will Mitsubishi Electric be liable or responsible for any consequential damage that may arise as a result of the installation or use of this equipment e All examples and diagrams shown in this manual are intended only as an aid to understanding the text not to guarantee operation Mitsubishi Electric will accept no responsibility for actual use of the product based on these illustrative examples e Owing to the very great variety in possible application of this
6. CC Link cable is used 130 Q 1 2 W brown orange and brown e The master module can be connected besides to the both ends e Star connection is not allowed e The figure below shows the connection method Important Make sure to use only one type of cable dedicated CC Link cables OR dedicated CC Link high performance cables If both types of cables are used together normal data transmission cannot be guaranteed The shielded dedicated CC Link cable should go through the terminals SLD and FG in each module and both ends should be grounded Class D solid grounding The terminals SLD and FG are connected each other inside the module Master module Remote module Remote module Terminal DA i i DA i i DA Terminal i resistor resistor DB y y DB y y 5E i DG LY a pe 1 DG Pa Po l SLD Dedicated CC Link cable SLD Dedicated CC Link cable SLD m m 3 SPECIFICATION 3 1 General Specification Dielectric strength 500V AC for 1 minute between the case and the PLC ground Other specification is equivalent to that of the PLC main unit 3 2 Performance Specification tem Specification Master station function The local station and standby master station functions Applicable function are not provided CC Link version Ver 1 10 Selectable by rotary switch among 156 kbps
7. N 32CCL two or more FX Series PLCs can be connected as remote device stations to configure a simple distributed system CC Link master block a FX2N 16CCL M Remote I O station 00000 oooo O 7 FX1N FX2N FX2NC Series PLC Partner manufacturer s product Remote I O station 00000 0000 PS Remote device station Remote device station FXoN FX1N FX2N FX2Nc CC Link interface block Series PLC FX2N 32CCL 1 3 Dimensions and Setting Dimensions mm inches MASS Weight 0 4 kg 0 88 Ibs 85 3 34 87 3 43 75 2 95 7 2 04 5 Os at ae TEST1 1 lt 4 L JIO 2 2 SIE o 5 BE sm Da o SE E AEE PT AEA E EH te Description D o LED status indicators 1 name escription ON Module is normal N OFF Watchdog time error has occurred O ON ia F ON Indicates the communication status with the stations set in parameter ON Communication error has ON or FF occurred in all stations flashing Flashing Communication error has occurred in some stations N O MST ON Setas the master station Test result indication Test res
8. N 32CCL JY992D71801 Describes programming and handling of the CC User s Manual packed with product Link interface block FX2N 32CCL Indispensable manual x Manual required depending on equipment used JY992D89301 packed with product xFX N Hardware Manual JY992D66301 yw FX2N Hardware Manual packed with product yFX2NC Hardware Manual 1 2 Overview The CC Link master block FX2N 16CCL M is a special extension block which assigns an FX Series PLC as the master station of the CC Link system 1 Remote I O stations and remote device stations can be connected to the master station FX Series PLC Master station Station which controls the data link system Remote I O station Remote station which handles only the 1 bit information Remote device station Remote station which handles both bit information and word information 2 By using the CC Link interface block FX2N 32CCL two or more FX Series PLCs can be connected as remote device stations to configure a simple distributed system CC Link master block FX2N 16CCL M Partner manufacturer s product Remote I O station pedi J FX1N FX2N FX2NC Series PLC Remote I O station 00000 oooo I Remote device station Remote device station A FXON FX1N FX2N FX2NC CC Link interface block Series PLC FX2N 32CCL 1 3 Dimensions and Setting Dimensions mm inches MASS Weig
9. O points of the PLC Remote device stations 8 maximum The following condition must be satisfied 1xa 2xb 3xc 4xd lt 8 Maximum number of a Number of remote device stations occupying 1 station connected modules b Number of remote device stations occupying 2 stations c Number of remote device stations occupying 3 stations d Number of remote device stations occupying 4 stations Number of remote I O stations Number of remote device stations lt 15 Maximum number of I O points per system below shall be satisfied For the system configuration calculation refer to USER S MANUAL Connection is allowed as far as the following condition is satisfied Actual number of I O points of PLC Number of points occupied by Maximum number of I O special extension blocks Number of points occupied by FX2N 16CCL points per system M 8 32 x Number of remote I O modules lt 256 FX2N FX2Nc Series PLC or 128 FX1N Series PLC For the system configuration calculation refer to USER S MANUAL Remote O station Remote I O 32 32 RX RY points Remote device station Remote I O 32 32 RX RY points Number of link points Remote register 4 RWw points per station master station remote device station Remote register 4 RWr points remote device station master station Communication method Polling method o ttem Specification ransmission format Connection cable Dedicated CC Link cable Dedicated hig
10. d cables specified by the manufacturer The performance of the CC Link system cannot be guaranteed with any cable other than dedicated ones specified by the manufacturer For the maximum total extension length and the cable length between stations observe the specification described in USER S MANUAL With wiring outside the specification range normal data transfer cannot be guaranteed e Make sure to fix communication cables and power cables connected to the module by placing them in the duct or clamping them Cables not placed in duct or not clamped may hang or shift allowing them to be accidentally pulled which may result in malfunction or damage to the module and the cables e When disconnecting a communication power cable connected to the module do not hold the cable area For a cable with connector hold the connector attached to the module For a cable connected to a terminal block loosen screws of the terminal block then disconnect the cable If a cable is pulled while it is connected to a module the module may malfunction or the module and the cable may be damaged WIRING PRECAUTIONS e Perform Class D grounding solid grounding with a wire of 2 mm or more to the grounding terminal in the PLC main units However never perform common grounding with a high voltage system Another Another PLC equipment PLC equipment PLC L l xo o Another equipment Common grou nding no
11. h performance CC Link cable e Automatic return function e Slave station cutoff function e Error detection by link special relay register Number of times of parameter registration Approximately 10 000 times to EEPROM Connectable PLC FXiN FX2N V 2 20 or later and FX2Nc V 2 20 or later Series PLC Number of occupied 8 I O points of FX Series PLC 8 points in total The ratio between inputs and I O points outputs is arbitrary ommunication with PLC By FROM TO instructions via the buffer memory e Scan method Asynchronous mode Automatic refresh Not provided Note Local station function Not provided Standby master station function Not provided Intelligent device station connection function Not provided Lit while 24V DC is supplied from outside Lit while communication is normal Operation indication Lit when communication error has occurred Lit while data is being transmitted Lit while data is being received o PAA RANE Supplied from 24V DC 150 mA external terminal block eae internal power 5 DC is self supplied 5V DC of PLC is not used Terminal resistor e For standard cable 110 Q 1 2 W color cable brown brown and brown 2 cables e For high performance cable 130 Q 1 2 W color cable brown orange and brown 2 cables Special block number label MASS Weight 0 4 kg 0 88 Ibs 1 Dedicated CC Link cables and dedicated high performance CC Link cables cannot be used at the same time Only ei
12. ht 0 4 kg 0 88 Ibs 85 3 34 87 3 43 75 2 95 2 04 5 TEST1 TEST2 cle ls a J 8 n p SIE 5 5 lt 12 BT eons 11 FX2n 16CCL M z siia es 6 5 allij kss 7 i x 406 x 888 0 0 oO NI oO gLogvresd 2 eof ro amp Se eof v ys An X ye ei Xe X PAE BEEN gt Ae DE D S3lzo 8S AMEE O0000000 Bozan 9 0 35 Inside of top cover Description LED LED D oti LED status indicators 1 name aa ON Module is normal BUN OFF Watchdog time error has occurred ON OFF ON Indicates the communication status with the stations set in parameter ON Communication error has ON or OFF occurred in all stations flashing Flashing Communication error has occurred in some stations ON MST ON Set as the master station ON OFF EST Test result indication oreren diaes EST2 Test result indication p g ON Data link is being executed ON host station OFF ON Communication error has occurred host station ON or Fla
13. lace with vibration or impact Using the module outside the range of the general specification may result in electrical shock fire malfunctions or may damage the PLC e When drilling screw holes or performing wiring make sure that cutting chips wire chips or other foreign matter does not enter the ventilation window of the module Such matter may cause fire failure or malfunction e When the installation work is completed remove the dust protection sheet from the ventilation window of the PLC If the sheet remains attached it may cause fire failure or malfunction e Securely connect extension cables to specified connectors Poor contact may cause malfunction WIRING PRECAUTIONS e Before beginning any installation or wiring work make sure all phases of the power supply have been shut down from the outside Incomplete shutdown of the power supply phases may cause electrical shock or damage in the module e Following an installation or wiring work when turning on the power supply and operating the PLC make sure that the terminal cover provided as an accessory has been attached to the module Non attachment of the cover may cause electrical shock e For the CC Link system use dedicated cables specified by the manufacturer The performance of the CC Link system cannot be guaranteed with any cable other than dedicated ones specified by the manufacturer For the maximum total extension length and the cable length between stati
14. lor cable brown orange and brown 2 cables Special block number label MASS Weight 0 4 kg 0 88 Ibs 1 Dedicated CC Link cables and dedicated high performance CC Link cables cannot be used at the same time Only either type of cables are available Attach a terminal resistor in accordance with the cable type 2 When an FXanc Series PLC is connected the interface FX2Nc CNV IF is required Approximately 10 000 times Operation indication Manual number JY992D93201 Manual revision A Date JAN 2001 a MITSUBISHI ELECTRIC CORPORATION HEAD OFFICE MITSUBISHI DENKI BLDG MARUNOUTI TOKYO 100 8310 TELEX J24532 CABLE MELCO TOKYO HIMEJI WORKS 840 CHIYODA CHO HIMEuvI JAPAN Effective JAN 2001 Specifications are subject to change without notice JY992D93201A
15. lt the nearest Mitsubishi Electric distributor e Under no circumstances will Mitsubishi Electric be liable or responsible for any consequential damage that may arise as a result of the installation or use of this equipment e All examples and diagrams shown in this manual are intended only as an aid to understanding the text not to guarantee operation Mitsubishi Electric will accept no responsibility for actual use of the product based on these illustrative examples e Owing to the very great variety in possible application of this equipment you must satisfy yourself as to its suitability for your specific application Note s on the symbology used in this manual At various times through out this manual certain symbols will be used to highlight points of information which are intended to ensure the user s personal safety and protect the integrity of the equipment Whenever any of the following symbols are encountered its associated note must be read and understood Each of the symbols used will now be listed with a brief description of its meaning Hardware warnings A 1 Indicates that the identified danger WILL cause physical and property damage A 2 Indicates that the identified danger could POSSIBLY cause physical and property damage 1 INTRODUCTION 1 1 Associated Manuals Manual name Manual number Description FX2N 16CCL M JY992D93101 Describes programming and handling of the CC User s Manual sent separately Link ma
16. odule in the environment described in the USER S MANUAL General Specification Do not use the PLC in a place with dust soot conductive dust corrosive gas or combustible gas place exposed to high temperature condensation wind or rain or place with vibration or impact Using the module outside the range of the general specification may result in electrical shock fire malfunctions or may damage the PLC e When drilling screw holes or performing wiring make sure that cutting chips wire chips or other foreign matter does not enter the ventilation window of the module Such matter may cause fire failure or malfunction e When the installation work is completed remove the dust protection sheet from the ventilation window of the PLC If the sheet remains attached it may cause fire failure or malfunction e Securely connect extension cables to specified connectors Poor contact may cause malfunction WIRING PRECAUTIONS e Before beginning any installation or wiring work make sure all phases of the power supply have been shut down from the outside Incomplete shutdown of the power supply phases may cause electrical shock or damage in the module e Following an installation or wiring work when turning on the power supply and operating the PLC make sure that the terminal cover provided as an accessory has been attached to the module Non attachment of the cover may cause electrical shock e For the CC Link system use dedicate
17. on master station Communication method _ Polling method Maximum number of connected modules Maximum number of I O points per system Number of link points per station Oo oten ES Uification Error control method CROX pe i Dedicated CC Link cable Dedicated high performance CC Link cable Automatic return function Slave station cutoff function Error detection by link special relay register Number of times of parameter registration to EEPROM Connectable PLC FX1N FX2N V 2 20 or later and FX2nc V 2 20 or later Series PLC Number of occupied 8 I O points of FX Series PLC 8 points in total The ratio between inputs and I O points outputs is arbitrary ommunication with PLC By FROM TO instructions via the buffer memory e Scan method Asynchronous mode Automatic refresh Not provided Local station function Not provided Standby master station function Not provided Intelligent device station connection function Not provided Lit while 24V DC is supplied from outside Lit while communication is normal Lit when communication error has occurred Lit while data is being transmitted Lit while data is being received RD l ae a Supplied from 24V DC 150 mA external terminal block bell EE pOr 5V DC is self supplied 5V DC of PLC is not used Terminal resistor e For standard cable 110 Q 1 2 W color cable brown brown and brown 2 cables e For high performance cable 130 Q 1 2 W co
18. ons observe the specification described in USER S MANUAL With wiring outside the specification range normal data transfer cannot be guaranteed e Make sure to fix communication cables and power cables connected to the module by placing them in the duct or clamping them Cables not placed in duct or not clamped may hang or shift allowing them to be accidentally pulled which may result in malfunction or damage to the module and the cables e When disconnecting a communication power cable connected to the module do not hold the cable area For a cable with connector hold the connector attached to the module For a cable connected to a terminal block loosen screws of the terminal block then disconnect the cable If a cable is pulled while it is connected to a module the module may malfunction or the module and the cable may be damaged WIRING PRECAUTIONS e Perform Class D grounding solid grounding with a wire of 2 mm or more to the grounding terminal in the PLC main units However never perform common grounding with a high voltage system Another Another Another PLC equipment PLC equipment PLC equipment Se Dedicated grounding Common grounding Common grounding best allowed not allowed e Do not bundle control cables and communication cables with the main circuit and power cables Keep control cables and communication cables at least 100 mm away from the main circuit and
19. power cables Otherwise electric noise may cause a malfunction 2 1 Installation Install the FX2N 16CCL M on the right side of an FX1N FX2N FX2NcC Series main unit extension unit or another extension block For the FX2Nc Series the FX2Nc CNV IF is required The FX2N 16CCL M can be installed using a DIN rail DIN 46277 width 35 mm 1 38 in or directly with M4 0 16 in screws In the case of direct installation provide space of 1 to 2 mm 0 04 to 0 08 in between units 2 2 Dedicated CC Link Cable Use dedicated CC Link cables in the CC Link system If any other cable is used the performance of the CC Link system cannot be guaranteed 2 3 Module Wiring with Dedicated CC Link Cables This section describes the connection method of dedicated CC Link cables e The cables can be connected without regard to the station number e Make sure to connect a terminal resistor offered as an accessory of the module between the terminals DA and DB in modules at both ends e Inthe CC Link system the terminal resistor to be connected varies depending on the used cable When a dedicated CC Link cable is used 110 Q 1 2 W brown brown and brown When a dedicated high performance CC Link cable is used 130 Q 1 2 W brown orange and brown e The master module can be connected besides to the both ends e Star connection is not allowed e The figure below shows the connection method Important Make sure to use only one type of
20. shing The settings of the switches 4 OFF flashing to 7 are changed while the power is ON POWER ON 24V DC is supplied from the outside m m JJ J C J Z indicators 2 number setting switch STATION NO x 10 Condition setting switch v ez9Ssrtrez 2 T iw Terminal block ad vd 950 qIS Extension cable Next step extension connector 12 DIN rail mounting groove Description ON Switch setting error has occurred 3 oF i N ON The master station is already MIS present in the same line O RM JON Parameter setting error has occurred O N ON The cable is broken or the transmission route is affected by O N ON Data is being transmitted ON OFF ON Data is being received 0 ON OFF FF i i FF IME ON Data link watchdog timer is actuated FF O error in all stations FF O noise etc ON ON Sets the station number of the module Default setting at shipment 00 lt Setting range gt 00 because the FX2N 16CCL M is dedicated to the master station lf 65 or larger number is set the SW and L ERR LED indicators turn ON Sets the operation s
21. ster block FX2N 16CCL M k FX1S FX1N FX2N FX2NC JY992D88101 Explains the instructions in the FX1S FX1N FX2N Programming Manual II sent separately FX2Nc Series PLC Describes the contents related to the hardware such as specification wiring and mounting of the FX1N Series PLC Describes the contents related to the hardware such as specification wiring and mounting of the FX2N Series PLC Describes the contents related to the hardware such as specification wiring and mounting of the FX2Nc Series PLC yw FX2N 32CCL JY992D71801 Describes programming and handling of the CC User s Manual packed with product Link interface block FX2N 32CCL Indispensable manual yr Manual required depending on equipment used JY992D89301 packed with product yxFX1N Hardware Manual JY992D66301 wFX2N Hardware Manual packed with product JY992D76401 yeF X2NC Hardware Manual packed with product 1 2 Overview The CC Link master block FX2N 16CCL M is a special extension block which assigns an FX Series PLC as the master station of the CC Link system 1 Remote I O stations and remote device stations can be connected to the master station FX Series PLC Master station Station which controls the data link system Remote I O station Remote station which handles only the 1 bit information Remote device station Remote station which handles both bit information and word information 2 By using the CC Link interface block FX2
22. t allowed Dedicated grounding Common grounding best allowed e Do not bundle control cables and communication cables with the main circuit and power cables Keep control cables and communication cables at least 100 mm away from the main circuit and power cables Otherwise electric noise may cause a malfunction 2 1 Installation Install the FX2N 16CCL M on the right side of an FX1N FX2N FXanc Series main unit extension unit or another extension block For the FX2Nc Series the FX2NC CNV IF is required The FX2N 16CCL M can be installed using a DIN rail DIN 46277 width 35 mm 1 38 in or directly with M4 0 16 in screws In the case of direct installation provide space of 1 to 2 mm 0 04 to 0 08 in between units 2 2 Dedicated CC Link Cable Use dedicated CC Link cables in the CC Link system If any other cable is used the performance of the CC Link system cannot be guaranteed 2 3 Module Wiring with Dedicated CC Link Cables This section describes the connection method of dedicated CC Link cables e The cables can be connected without regard to the station number e Make sure to connect a terminal resistor offered as an accessory of the module between the terminals DA and DB in modules at both ends e Inthe CC Link system the terminal resistor to be connected varies depending on the used cable When a dedicated CC Link cable is used 110 Q 1 2 W brown brown and brown When a dedicated high performance
23. tatus of the module Default setting at shipment 0 o Online Sets connection to data ink O s O S Parameter i Refer to USER S MANUAL 6 Hardware test Refer to USER S MANUAL 7 Setting error The SW LED indicator turns ON 8toA Unusable Cannot be set because it is already used inside BtoF Unusable Setting error The SW LED indicator turns ON ets the transmission speed of the module Default setting at shipment 0 Number Setting contents 156 kbps 625 kbps 2 5 Mbps 5 Mbps 10 Mbps 5to9 Setting error The SW and L ERR LED indicators turn ON ets the operation condition Default setting at shipment All OFF Number Setting description Switch status O FF O ep e s SW1 to sw3 Unusable Always OFF Keep Clear SW4 Input data status in data link faulty station HLD CLR SW5 to Unusable Always OFF Cp g ee Connects dedicated CC Link cables to enable data link For the connection method refer to Section 2 3 The terminals SLD and FG are connected inside Connects the PLC Connects an extension equipment DIN46277 DIN rail mounting groove of 35 mm 1 38 in width 2 Installation and wiring A INSTALLATION PRECAUTIONS e Use the module in the environment described in the USER S MANUAL General Specification Do not use the PLC in a place with dust soot conductive dust corrosive gas or combustible gas place exposed to high temperature condensation wind or rain or p
24. ther type of cables are available Attach a terminal resistor in accordance with the cable type 2 When an FXanc Series PLC is connected the interface FX2Nc CNV IF is required Accessories Manual number JY992D93201 Manual revision A Date JAN 2001 Aa MITSUBISHI ELECTRIC CORPORATION HEAD OFFICE MITSUBISHI DENKI BLDG MARUNOUTI TOKYO 100 8310 TELEX J24532 CABLE MELCO TOKYO HIMEJI WORKS 840 CHIYODA CHO HIMEJI JAPAN Effective JAN 2001 Specifications are subject to change without notice JY992D93201A ADVANCED AND EVER APVANCINS MITSUBISHI ELECTRIC a MITSUBISHI PROGRAMMABLE CONTROLLERS MELSECE CC Link FX2N 16CCL M CC Link SYSTEM MASTER BLOCK HARDWARE MANUAL JY 992D93201A This manual contains text diagrams and explanations which will guide the reader in the correct installation and operation of the FX2N 16CCL M CC Link SYSTEM MASTER BLOCK It should be read and understood before attempting to install or use the unit Further information can be found in the FX series PLC hardware manuals Guidelines for the safety of the user and protection of the FX2N 16CCL M CC Link SYSTEM MASTER BLOCK e Ifin doubt at any stage during the installation of the FX2N 16CCL M CC Link SYSTEM MASTER BLOCK always consult a professional electrical engineer who is qualified and trained to the local and national standards If in doubt about the operation or use of the FX2N 16CCL M CC Link SYSTEM MASTER BLOCK please consu
25. ult indication ON Data link is being executed host station OE ON Communication error has occurred host station ON or Flashing The settings of the switches 4 OFF to 7 are changed while the power is ON POWER ON 24V DC is supplied from the outside ON m HE flashing u 2 lolo D Z n3 Description ON Switch setting error has occurred ON The master station is already E me present in the same line R PRM ON Parameter setting error has occurred R 7 O TIME ON Data link watchdog timer is actuated OFF ON error in all stations ON The cable is broken or the LINE transmission route is affected by OFF ON noise etc SD JON Data is being transmitted RD ON Data is being received Sets the station number of the module Default setting at shipment 00 0p indicators 2 Station number setting switch lt Setting range gt STATIONNo 00 because the FX2N 16CCL M is dedicated to the master station lf 65 or larger number is set the SW and L ERR LED indicators turn ON x 10 Sets the operation status of the module Default setting at shipment 0 o Onine Sets connection todatalink O s O S Parameter Refer to USER S MANUAL 6 Hardware test Refer to USER S MANUAL 7 Setting