1. Illuminator User Guide Ultima Illuminator Models Covered by this manual UFO 250 UG A UFO 250 UP A UFO 250 UGC A UFO 250 UPC A UFO 250 UGCF A UFO 250 UPCF A UFO 250 UGCFF A UFO 250 UPCFF A UFO 250 UGCS A UFO 250 UPCS A UFO 250 UGCFS A UFO 250 UPCFS A UFO 250 UGCSS A UFO 250 UPCSS A Universal Fiber Optics LLC 6119A Clark Center Avenue Sarasota Florida 34238 Tel 1 800 UFO 5554 Tel 941 343 8115 Issue 2 Revised 24072013 www fiberopticlighting com INTRODUCTION Thank you for purchasing this UFO illuminator Please read these instructions fully before connecting your unit to the electrical supply and keep them for future reference A high performance 250W metal halide illuminator for ultimate brightness which can be fitted with a choice of wheels for decorative lighting effects IMPORTANT THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE INSTALLATION CODE BY A PERSON FAMILIAR WITH THE CONSTRUCTION AND OPERATION OF THE PRODUCT AND THE HAZARDS INVOLVED Do not operate without complete lamp enclosure in place or if lens is damaged KEEP HARNESS IN PLACE WHEN IN OPERATION CAUTION Hot surface Keep away from curtains and other combustible materials WARNING RISK OF FIRE INJURY TO PERSONS Keep away from combustibles Unplug to change lamp Do not touch lamp WARNING RISK OF FIRE Do not place lamp where the overhead surface is closer than 0 3m to the illuminat
2. Description Mains Input Socket Fuse Drawer Power Indicator Light Cooling Fan Separate Feed Power Inputs Fiber Port Motor Covers 4 Access Screws 4 x Mounting Holes INSTALLATION GUIDE In order for the Ultima illuminator to function safely and efficiently it must be installed according to this user manual Please read all sections thoroughly before switching on the illuminator POWER SUPPLY REQUIREMENTS Before plugging in the unit please make sure that the supply is correct Failure to do so could cause the unit to malfunction The unit requires a 120VAC 60Hz supply and it MUST BE EARTHED The illuminator units are provided with a cordset fitted with a standard plug UNIT MUST NOT BE DIMMED POSITIONING THE UNIT Standard horizontal mounting on shelf table Vertical mounting fixed to wall Upside down mounting fixed to underside of shelf The illuminator can be mounted horizontally vertically or upside down on any flat surface Keyhole slots are provided on the base of the unit to allow for securing to a surface The illuminator is only suitable for use in a dry area If the unit is being mounted at a higher than the ground level block access below the work area before installing Verify that any screws or bolts can safely bear the weight of the illuminator INSTALLATION GUIDE Continued Verify that the supporting structure can safely bear the weight of all installed units cables an
3. d any other equipment For horizontal mounting it is recommended that the illuminator is secured to a solid surface using 4 x M4 or M5 screws or bolts and the keyhole slots This is particularly important if the illuminator location is not at ground floor level To mount the illuminator vertically first securely install 4 x M4 or M5 screws or bolts at the required distances so that they will line up with the keyhole slots The illuminator can then be mounted onto them and slid into position The bolts or screws MUST then be fully tightened To mount the illuminator under a surface first securely install 4 x M4 or M5 screws or bolts at the required distances so that they will line up with the keyhole slots The illuminator can then be mounted onto them and slid into position The bolts or screws MUST then be fully tightened CLEARANCE VENTILATION It is recommended that a gap of 300mm or more is left around the unit This is to allow air to circulate and prevent overheating The location must have free ventilation INSTALLATION GUIDE Continued CONNECTION There are 2 main connections required the fiber port and the mains power supply Connect and secure the fiber optic connector to the fiber port before connecting the electrical supply Never run the illuminator with the fiber connector unplugged For separate feed units there will be additional power connections required OPERATION After installing and connecting the il
4. luminator as described above all you have to do is turn the power on The lamp will take 3 4 minutes to reach full brightness This is normal for this type of illuminator If no light is produced please consult the TROUBLESHOOTING section in this manual MAINTENANCE LAMP REPLACEMENT 1 Disconnect the illuminator from the power supply and allow to cool for 10 to 15 minutes 2 Remove the cover A from the illuminator 3 The lamp is located near the rear of the illuminator To free the lamp from its holder gently pull the lamp forwards B DO NOT unscrew the brass holder C as this will impair the light output 4 Dispose of the old lamp carefully 5 Fit the new lamp D DO NOT touch the lamp glass as this may cause it to EXPLODE If you do carefully clean it with a lint free cloth and alcohol 6 Replace the lid and reconnect to the power supply FUSE REPLACEMENT 1 Unplug unit from electrical supply and allow to cool 2 The fuse is located in a drawer under the mains input connector 3 Open the fuse drawer 4 Withdraw fuse from its holder 5 Replace with identically specified fuse see specification table in this manual 6 Close the fuse drawer and power up the illuminator MAINTENANCE Continued CLEANING THE UNIT Disconnect unit from power supply and allow to cool before attempting any cleaning of the unit The body of the unit can be cleaned with a soft damp cloth do not use a
5. mp off randomly Unit is overheating No power to separate feed Decorative wheel not turning on separate electrical feed models Motor faulty 10 TECHNICAL SPECIFICATIONS Description Ultima 250W Philips MSD250 2 Glass BLV MHR 250N PMMA c 3000h Glass c 4000h PMMA 8500K Glass 4200K PMMA 70 Glass 72 PMMA L 16 407mm x W 11 4 290mm x H 6 5 165 mm NOTES 11 NOTES NOTES 11 NOTES UNIVERSAL FIBER OPTICS Universal Fiber Optics LLC 6119A Clark Center Avenue Sarasota Florida 34238 Tel 1 800 UFO 5554 Tel 941 343 8115 www fiberopticlighting com
6. ny abrasives on the unit The fans and vents should be kept clear by periodically blowingthem out with compressed air Non abrasive glass cleaner can be used to clean the glass lens inside the unit Please note that a record of all maintenance MUST be kept in the table below indicating what maintenance was undertaken and when Maintenance Undertaken Remedy Main fuse blown Check and replace fuse Check that power is switched on and power supply 15 plugged in Replace lamp Allow unit to cool for 5 to 10 minutes and investigate reason for overheating Check plug connection ensure lamp is properly seated in its holder and the pins are fully mated TROUBLESHOOTING Probable cause s Unit is completely dead Lamp and LED power indicator are not illuminated AIG power toum Lamp blown Thermal switch activated LED power indicator amp fan are on but no light is output Lamp wires are not connected Lamp needs replacing Replace lamp Unit needs cleaning Clean reflector and glass lens Poor light output Incorrect power supply Ensure power supply is 120VAC 60Hz Ensure fiber port connector is plugged in correctly and that the screw is tightened up properly Allow unit to cool for 5 to 10 minutes and investigate reason for overheating Check power is switched on and unit is plugged in Check and replace fuse if necessary Replace motor Fiber port connector not plugged in correctly Lamp going on a
7. or IMPORTANT SAFETY INFORMATION INSTRUCTIONS PERTAINING TO A RISK OF FIRE ELECTRIC SHOCK OR INJURY TO PERSONS IMPORTANT SAFETY INSTRUCTIONS Lighted Lamp is HOT WARNING To reduce the risk of FIRE ELECTRIC SHOCK OR INJURY TO PERSONS 1 Unplug and allow to cool before replacing lamp 2 Lamp gets HOT quickly Only contact plug when turning on 3 Do not touch hot lens guard or enclosure 4 Do not remain in light if skin feels warm 5 Do not look directly at lighted lamp 6 Keep lamp away from materials that may burn 7 Use only with an approved 250W lamp 8 Do not touch the lamp at any time Use a soft cloth Oil from skin may damage lamp 9 Do not operate product with missing or damaged guard lamp containment barrier lens or fiber optic harness SAVE THESE INSTRUCTIONS e Always disconnect the unit from the power supply before opening or attempting to perform any work on it e UNIT MAY GET HOT always allow unit to cool down before handling or moving it Do not touch or attempt to remove the lamp while it is hot e Ensure that the power supply is correct for the unit before powering it up e Always ensure that the unit is properly EARTHED e Do not expose the unit to rain or moisture e Keep away from all combustible materials e Never attempt to tamper with the wiring or other internal components e Keep the unit away from gas oil and any other flammable or explosive materials ILLUMINATOR LAYOUT