Home

EKI-2525P User Manual

image

Contents

1. r44s4400 18 Appendix A Pin Assignment amp Wiring 20 Figure A 1 RJ 45 Pin Assignment 20 Figure A 2 EIA TIA 568B ee 20 Figure A 2 EIA TIA 568A eseese 20 vii Contents EKI 2525P User Manual doc Vill CHAPTER Overview Sections include e Introduction e Features e Specifications e Packing List e Safety Precaution Chapter 1 Overview 1 1 Introduction The EKI 2525P is a cost effective solution and meets the high reliability requirements demanded by industrial applications Using fiber port can extend the connection distance that increases the network elasticity and performance Besides the industrial switch provides the PoE function for kinds of Powered Devices to receive power as well as data over the RJ 45 1 1 1 High Speed Transmissions The EKI 2525P includes a switch controller that can automatically sense transmission speeds 10 100 Mbps The RJ 45 interface can also be auto detected so MDI or MDI X is automatically selected and a crossover cable is not required All Ethernet ports have memory buffers that support the store and forward mechanism This assures that data is properly transmitted 1 1 2 Power over Ethernet PoE PoE eliminates the need to run AC power to other devices on a wired LAN While using Power over Ethernet system installers need to run only a single Category 5 Ethernet cable that carries both power and data to each device This allows greater flexibility in
2. 2 1 1 3 Dual Power Input u n en 2 1 1 4 Flexible Mounting 4 ss nn 2 1 1 5 Advanced Protection 0 400 gt 2 1 1 6 Wide Operating Temperature 2 1 1 7 Easy Troubleshooting 2 1 2 Beate eee ane retain Sen 3 1 3 SPSCHICAU OMS ass to aan 4 1 A gt Packing LiSt Jensen 6 1 5 Safety Precaution ana sem linea 6 Chapter 2 Installation ccccseeeeeeeeseeeeeees 8 2 1 LED Indicator S sun sre se as 8 Table 2 1 EKI 2525P LED Definition 8 2 2 Dimensions units mm u en 9 Figure 2 1 Front View of EKI 2525P 9 Figure 2 2 Side View of EKI 2525P 10 Figure 2 3 Rear View of EKI 2525P 11 Figure 2 4 Top View of EKI 2525P 12 23 1MOURUNG seele 13 2 3 1 Wall mounting 444444ee nennen 13 Figure 2 5 Combine the Metal Mounting Kit units TO ee ee ee 13 2 3 2 DIN rail Mounting 4444 4000 14 Figure 2 6 Installation to DIN rail Step 1 14 Figure 2 7 Installation to DIN rail Step 2 15 2 4 Network Connection cccccccceeseeeeeeaeeeeesaeees 16 2 5 Power Connection cccccccsssecceeeeecseseeeseeees 16 Figure 2 8 Pin Assignment of the Power Connector 16 Chapter 3 Troubleshooting
3. 1 and 2 are both active or no power input On A device is connected utilizing Power over Ethernet on the corresponding port FWD 1 4 Green pencng p Off No device attached or power over Ethernet function failed On Connected to network aa Green Flashing Networking is active Off Not connected to network On Ethernet port full duplex ee Yellow Flashing Collision of packets occurs Off Ethernet port half duplex or not connect to network EKI 2525P User Manual doc 8 2 2 Dimensions units mm P1 P2 P Fail EEE E FWD 4m 3 m 2m ig EKI 2525P Figure 2 1 Front View of EKI 2525P 9 Chapter2 D007 1 party 104 00 Figure 2 2 Side View of EKI 2525P EKI 2525P User Manual doc 10 3 50 3 50 Figure 2 3 Rear View of EKI 2525P 11 Chapter2 Please refer to page 16 for pin assignment Figure 2 4 Top View of EKI 2525P EKI 2525P User Manual doc 12 2 3 Mounting The EKI 2525P supports two mounting methods DIN rail amp Wall 2 3 1 Wall mounting EKI 2525P can be wall mounted by using the included mounting kit Then hang on the EKI 2525P to the nails on the wall First use the screws included in the package to combine the EKI 2525P and metal mounting kit And then you can install the device firmly via the components please see Figure 2 5 as below EKI 2300x 158 00 Figure 2 5 Combine the Metal Mounting Kit units mm 13 Chapter2 2 3 2 DIN rail Mounting You
4. can also mount EKI 2525P on a standard DIN rail by below steps The DIN rail kit is screwed on the industrial switch when out of factory If the DIN rail kit is not screwed on the industrial switch please screw the DIN rail kit on the switch first First hang the EKI 2525P to the DIN rail with angle of inclination See figure 2 6 Figure 2 6 Installation to DIN rail Step 1 EKI 2525P User Manual doc 14 Then let the device down straight to slide over the rail smoothly See Figure 2 7 Figure 2 7 Installation to DIN rail Step 2 15 Chapter2 2 4 Network Connection The EKI 2525P has 5 x RJ 45 ports that support connection to 10 Mbps Ethernet or 100 Mbps Fast Ethernet and half or full duplex operation EKI 2525P can be connected to other hubs or switches through a twisted pair straight through the cable or a crossover cable up to 100m long The connection can be made from any TX port of the EKI 2525P MDI X to another hub or switch either MDI X or uplink MDI port The EKI 2525P supports auto crossover to make networking more easy and flexible You can connect any RJ 45 MDI X station port on the switch to any device such as a switch bridge or router 2 5 Power Connection The EKI 2525P supports dual 48 Voc power inputs and power fail relay output C PWR2 1A 12V PWRI BEN PLL V2 V2 LW V1 V1 P Fail Figure 2 8 Pin Assignment of the Power Connector You can connect an alarm indicator buzzer or other signaling
5. equipment through the relay output The relay opens if power input 1 or 2 fails Open means if you connect relay output with an LED the light would be off EKI 2525P User Manual doc 16 CHAPTER Troubleshooting Chapter 3 Troubleshooting 1 Power Input Verify that is using the right power cord adapter 48 Voc please don t use the power adaptor with DC output voltage higher than 48V or it will burn this converter down 2 Cable Select the proper UTP cable to construct user network Please check that is using the right cable Use Unshielded Twisted Pair UTP or Shielded Twisted Pair STP cable for RJ 45 connections 100 Category 3 4 or 5 cable for 10 Mbps connections or 100 Category 5 cable for 100 Mbps connections Also be sure that the length of any twisted pair connection does not exceed 100 meters 328 feet 3 Diagnosing LED Indicators The switch can be easily monitored through panel indicators which describes common problems user may encounter and where user can find possible solutions to assist in identifying If the power indicator does not light up when the power cord is plugged in user may have a problem with power cord Then check for loose power connections power losses or surges at power outlet If user still cannot resolve the problem contact the local dealer for assistance If the Industrial switch LED indicators are normal and the connected cables are correct but the packets still cannot transmit ple
6. the equipment For safety reasons the equipment should be opened only by qualified service personnel If one of the following situations arises get the equipment checked by service personnel a The power cord or plug is damaged b Liquid has penetrated into the equipment c The equipment has been exposed to moisture d The equipment does not work well or you cannot get it to work according to the user s manual e The equipment has been dropped and damaged f The equipment has obvious signs of breakage DO NOT LEAVE THIS EQUIPMENT IN AN ENVIRONMENT WHERE THE STORAGE TEMPERATURE MAY GO BELOW 40 C 40 F OR ABOVE 85 C 185 F THIS COULD DAMAGE THE EQUIPMENT THE EQUIPMENT SHOULD BE IN A CONTROLLED ENVIRONMENT Safety Precaution Static Electricity Follow these simple precautions to protect yourself from harm and the products from damage 1 To avoid electrical shock always disconnect the power from your PC chassis before you work on it Don t touch any components on the CPU card or other cards while the PC is on 2 Disconnect power before making any configuration changes The sudden rush of power as you connect a jumper or install a card may damage sensitive electronic components EKI 2525P User Manual doc vi Contents Chapter 1 OVervieW scscseeseeeeeeseseeeeeees 2 Tt Introductions a ea 2 1 1 1 High Speed Transmissions 2 1 1 2 Power over Ethernet PoE
7. EKI 2525P 5 port Industrial PoE Unmanaged Ethernet Switch User Manual Copyright The documentation and the software included with this product are copyrighted 2007 by Advantech Co Ltd All rights are reserved Advantech Co Ltd reserves the right to make improvements in the products described in this manual at any time without notice No part of this manual may be reproduced copied translated or transmitted in any form or by any means without the prior written permission of Advantech Co Ltd Information provided in this manual is intended to be accurate and reliable However Advantech Co Ltd assumes no responsibility for its use nor for any infringements of the rights of third parties which may result from its use Acknowledgements Intel and Pentium are trademarks of Intel Corporation Microsoft Windows and MS DOS are registered trademarks of Microsoft Corp All other product names or trademarks are properties of their respective owners Part No 2nd Edition Printed in China February 2008 EKI 2525P User Manual doc ii Product Warranty 2 years Advantech warrants to you the original purchaser that each of its products will be free from defects in materials and workmanship for two years from the date of purchase This warranty does not apply to any products which have been repaired or altered by persons other than repair personnel authorized by Advantech or which have been subject to misuse abuse accident or impr
8. ase check your system s Ethernet devices configuration or status EKI 2525P User Manual doc 18 A Pin Assignment amp Wiring APPENDIX Appendix A Pin Assignment amp Wiring It is suggested to adopt ELA TIA as the wiring of the RJ 45 Figure A 1 RJ 45 Pin Assignment 1 White Orange N Orange White Green Blue White Blue Green lt Pin nn LA Ping White Brown cor nN Brown Figure A 2 EIA TIA 568B N White Green N Green W White Orange Blue White Blue A Orange White Brown oo u A Brown Figure A 2 EIA TIA 568A EKI 2525P User Manual doc 20
9. e and ship it prepaid to your dealer iii Declaration of Conformity CE This product has passed the CE test for environmental specifications Test conditions for passing included the equipment being operated within an industrial enclosure In order to protect the product from being damaged by ESD Electrostatic Discharge and EMI leakage we strongly recommend the use of CE compliant industrial enclosure products FCC Class A This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense Technical Support and Assistance Step 1 Visit the Advantech web site at www advantech com support where you can find the latest information about the product Step 2 Contact your distributor sales representative or Advantech s customer service center for technical support if you need additional assistance Please have the following information ready before you ca
10. er Manual doc 2 1 2 Features Provides 5 x 10 100Base TX Ethernet ports with 4 PoE injectors of RJ 45 connector Supports full half duplex flow control Supports store and forward transmission Supports auto negotiation Supports MDI MDI X auto crossover Provides surge protection EFT 3 000 Vpc for power line Supports 4 000 Vpc ESD protection for Ethernet Supports 48 Vpc power input Provides flexible mounting DIN rail Wall Mounting Supports operating temperature from 10 60 C 3 Chapter 1 3 Specification Communications Compatibility LAN Transmission Distance Transmission Speed Interface Connectors LED Indicators Power Power Consumption Power Input Fault Output Mechanism Dimensions WxHxD Enclosure Mounting Protection ESD Ethernet Surge EFT for power Power Reverse Current Overload Protection Environment Operating Temperature Operating Humidity Storage Temperature EKI 2525P User Manual doc IEEE 802 3 802 3u 802 3x 802 3af 10 100Base TX Up to 100 m Up to 100 Mbps 5 x RJ 45 6 pin removable screw terminal power amp relay Unit P1 P2 P Fail TX port Link Active Duplex Collision 65 Watts Full load with PoE 2 x Unregulated 48 Voc 1 Relay Output 37 x 140 x 95 IP30 Metal shell with solid mounting kits DIN rail Wall 4 000 Voc 3 000 Voc Yes 3A 48Vp5c Re settable Fuse 10 60 C 5 95 non condensing 40 85 C Certifications Saf
11. ety UL 60950 1 CAN CSA C22 2 N0 60950 EMC U S A FCC Part 15 CISPR 22 EU EN55011 EN61000 6 4 EN55022 Class A EN61000 3 2 3 EN55024 IEC61000 4 2 3 4 5 6 8 EN61000 6 2 4 Free Fall IEC60068 2 32 Shock IEC60068 2 27 Vibration IEC60068 2 6 5 Chapter 1 4 Packing List 1 x EKI 2525P Industrial Ethernet Switch 1 x eAutomation Industrial Communication CD ROM with software and User manual 2x Wall Mounting Bracket and Screws 1 x DIN rail Mounting Bracket and Screws 1 x EKI 2525P Startup Manual 1 x DC Jack Cable 2 0 150mm 1 5 Safety Precaution Attention IF DC voltage is supplied by an external circuit please use a protection device on the power supply input EKI 2525P User Manual doc 6 CHAPTER Installation Sections include e LED Indicators e Dimensions e Mounting e Network Connection e Power Connection Chapter 2 Installation In this chapter you will be given an overview of the EKI 2525P hardware installation procedures 2 1 LED Indicators There are few LEDs display the power status and network status located on the front panel of EKI 2525P each of them has its own specific meaning as the table below Table 2 1 EKI 2525P LED Definition LED Color Description On Power input 1 is active P1 Green Off Power input 1 is inactive On Power input 2 is active P2 Green Off Power input 2 is inactive On Power input 1 or 2 is inactive P Fail Red Off Power input
12. ll Product name and serial number Description of your peripheral attachments Description of your software operating system version application software etc A complete description of the problem The exact wording of any error messages EKI 2525P User Manual doc iv Safety Instructions 1 2 3 an 10 11 12 13 14 15 Read these safety instructions carefully Keep this User s Manual for later reference Disconnect this equipment from any AC outlet before cleaning Use a damp cloth Do not use liquid or spray detergents for cleaning For plug in equipment the power outlet socket must be located near the equipment and must be easily accessible Keep this equipment away from humidity Put this equipment on a reliable surface during installation Dropping it or letting it fall may cause damage The openings on the enclosure are for air convection Protect the equipment from overheating DO NOT COVER THE OPENINGS Make sure the voltage of the power source is correct before connecting the equipment to the power outlet Position the power cord so that people cannot step on it Do not place anything over the power cord All cautions and warnings on the equipment should be noted If the equipment is not used for a long time disconnect it from the power source to avoid damage by transient overvoltage Never pour any liquid into an opening This may cause fire or electrical shock Never open
13. oper installation Advantech assumes no liability under the terms of this warranty as a consequence of such events Because of Advantech s high quality control standards and rigorous testing most of our customers never need to use our repair service If an Advantech product is defective it will be repaired or replaced at no charge during the warranty period For out of warranty repairs you will be billed according to the cost of replacement materials service time and freight Please consult your dealer for more details If you think you have a defective product follow these steps 1 Collect all the information about the problem encountered For example CPU speed Advantech products used other hardware and software used etc Note anything abnormal and list any onscreen messages you get when the problem occurs 2 Call your dealer and describe the problem Please have your manual product and any helpful information readily available 3 If your product is diagnosed as defective obtain an RMA return merchandize authorization number from your dealer This allows us to process your return more quickly 4 Carefully pack the defective product a fully completed Repair and Replacement Order Card and a photocopy proof of purchase date such as your sales receipt in a shippable container A product returned without proof of the purchase date is not eligible for warranty service 5 Write the RMA number visibly on the outside of the packag
14. the locating of network devices and significantly decreasing installation costs in many cases 1 1 3 Dual Power Input EKI 2525P redundant power input design is with power reserve protection to prevent the switch device broken by wrong power wiring When one of power input is fail P Fail LED will turn on and send an alarm through a relay output for notifying user 1 1 4 Flexible Mounting EKI 2525P is extremely compact 37 x 140 x 95 mm and can be mounted on a DIN rail or a panel so it is suitable for any space constrained environment 1 1 5 Advanced Protection EKI 2525P supports up to 3 000 VDC surge protection for power line and also supports 4 000V ESD for Ethernet ports With these 2 strong protections it can secure equipment against unregulated voltage and make systems safer and more reliable Further EKI 2525P provides currency overload protection with a resettable fuse to ensure that the device component won t be damaged by overload current 1 1 6 Wide Operating Temperature The operating temperature of the EKI 2525P is between 10 60 C With such a wide range you can use the EKI 2525P in some of the harshest industrial environments that exist 1 1 7 Easy Troubleshooting LED indicators make troubleshooting quick and easy Each 10 100 Base TX port has 2 LEDs that display the link status transmission speed and collision status Also the three power indicators P1 P2 and P Fail help you diagnose immediately EKI 2525P Us

Download Pdf Manuals

image

Related Search

Related Contents

Ikelite 6240.97 underwater camera housing    WICHTIGE SICHERHEITSHINWEISE    BitTorrent Sync - The Insight Centre for Data Analytics  Polycom® RealPresence® Capture Server - Guia  Gear Head AU1200M headset  Manual del Propietario  カタログ(PDF:1477KB)  

Copyright © All rights reserved.
Failed to retrieve file