1. 17 of 35 Table 5 Maximum Manifold Length Based on Individual Lateral Flow Rates and 2 Foot Lateral Spacing Individual Lateral Discharge Rate 1 1 4 1 1 2 2 3 End Center Diameter Diameter Diameter Diameter Manifold Manifold Manifold Manifold Manifold Manifold 10 5 6 ft 8 ft 12 ft 18 ft 20 10 4 ft 6 ft 8 ft 14 ft 30 15 2 ft 4 ft 6 ft 12 ft 40 20 2 ft 2 ft 6 ft 10 ft 50 25 NP 2 ft 4 ft 8 ft 60 30 NP 2 ft 4 ft 8 ft 70 35 NP NP 2 ft 6 ft 80 40 NP NP 2 ft 6 ft 90 45 NP NP 2 ft 6 ft 100 50 NP NP 2 ft 4 ft Note a NP means Not Permitted Table 6 Friction Loss foot 100 feet in Plastic Pipe Flow in Nominal Pipe Size GPM 1 1 4 1 1 2 2 3 4 10 2 50 11 2 99 12 3 51 13 4 07 14 4 66 1 92 Velocities in this area 15 5 30 2 18 are below 2 feet per second 16 5 97 2 46 17 6 68 2 75 18 7 42 3 06 19 8 21 3 38 20 9 02 3 72 25 13 63 5 62 1 39 30 19 10 7 87 1 94 35 25 41 10 46 2 58 40 32 53 13 40 3 30 45 40 45 16 66 4 11 50 49 15 20 24 4 99 60 28 36 7 00 0 97 70 37 72 9 31 1 29 80 Velocities in this area exceed 10 ft 11 91 1 66 90 per second which are not acceptable 14 81 2 06 100 velocity for this pipe diameter 18 00 2 50 0 62 Note a Table is based on Hazen Williams formula h 0 002082L x 100 C x gpm a L Length
2. i Wis Adm Code Depth of stone aggregate under effluent gt 2 inches distribution network Depth of stone aggregate over effluent gt 2 to lt 6 inches distribution network Depth of pea gravel over underdrain pipe Depth of stone aggregate for underdrain gt 6 inches effluent collection 5 of 35 Table 3 OTHER SPECIFICATIONS continued Number of observation pipes 2 Two 4 inch pipes extending from the filter media aggregate interface to finished grade Location of observation pipes Located at a distance equal to approximately 1 6 the distribution cell length from each end along the center of the filter s width Difference in flow between any two lt 10 orifices in a single lateral Difference in flow between any two lt 15 orifices in the effluent distribution network Stone aggregate sieve specifications Aggregate Maximum minimum Gradation ASTM Standard C33 Size 4 coarse aggregate Sieve Size Passing 2 100 1 1 2 90 100 1 20 55 yA 0 15 3 8 0 5 Hardness Pea gravel sieve specifications Aggregate Maximum minimum Gradation ASTM Standard C33 Size 7 coarse aggregate Sieve Size Passing 3 4 100 y 90 100 3 8 40 70 4 0 15 8 0 5 6 of 35 Table 3 OTHER SPECIFICATIONS continued Pea gravel hardness specification gt value of 3 on Moh s Scale of Hardness Effective size of filter media D10 1 5 to 2 5 mm Uniformity C
3. Distribution Component Manual for Private Onsite Wastewater Treatment Systems publication Excavate and install the necessary tanks at the proper elevations and locations When a watertight container using a durable 30 mil PVC or 45 mil EPDM liner is used the following is required The liner must be protected from punctures that can be caused by sharp rocks and construction tools The filter can be placed at various elevations in the landscape from placement on the ground surface with soil mounded around it to buried with 21 of 35 the top 2 to 6 below original grade surface It is imperative that surface and ground water not be allowed to enter the filter The excavation is made 6 to 12 larger than the filter Untreated plywood waferboard or other suitable material is formed into a box to support the liner and allow the liner to be draped over the top Only sand is placed between the frame and soil to protect the liner after the plywood has decomposed Approximately 2 of sand is placed in the bottom of the excavation prior to placement of the liner The top of the liner must be above the seasonal high water table so groundwater does not flow into the sand filter When the excavation around the frame is backfilled it is done with sand that is placed in one foot increments and compacted by use of water or tamping prior to additional sand being placed Install a four inch diameter underdrain filtered effluent collection
4. Orifices orifices shall be located upward with orifice shields or a half pipe protecting the orifices from becoming blocked by aggregate b Laterals laterals are spaced two feet apart with an upturned long sweep elbow and valve for clean out The lateral length can not exceed that indicated in Graph 1 for various diameters Laterals are sloped back in order to provide drainage of the lateral between doses c Manifold manifolds slope back to provide drainage of the manifold between doses The manifold is sized using Table 5 d Force main Force mains slope back to provide drainage of the force main between doses The force main is sized using Table 6 e Recirculation tank pump the pump is sized to meet flow rate and lateral pressure of at least five feet at distal end The distribution network is placed in the stone aggregate with laterals and manifold sloping back to the force main Additional stone aggregate is placed on top of the network with a minimum cover of two inches The force main is placed through the tank wall The pipe penetration is sealed water tight by the use of a gasket to eliminate the intrusion of groundwater through the opening or to prevent ponded effluent from exiting 16 of 35 Latari Largih in Feat 160 140 120 100 80 60 40 20 Graph 1 Minimum Lateral Diameter Based on Orifice Spacing for 1 8 Diameter Orifices 0 5 1 1 5 Orifice Spacing in Feet
5. are connected to the top of the drain pipe Three to five of the pipes discharge effluent into the recirculation tank while the other one discharges effluent to a pipe which then flows to a pump tank or soil distribution dispersal cell 19 of 35 Figure 6 shows a method of designing a flow splitter fitting The flow splitter fitting may be constructed using proper components or it may be purchased ready to install p Forward flew port Eifuent discharge port ae a Ff i 4 v7 E long dunn tee i From sand fhar galid bulkhead pr Discharge to distribution dispersal cell of dose tank Conneed to by pass wahia Fig 6 Flow splitter fitting using pipe fittings 11 By pass valve The pipe connecting the by pass valve to the discharge pipe is installed on the discharge side of the flow control fitting by the use of a long turn tee fitting The by pass valve is set at an elevation that will open the valve during low or no flow conditions This elevation is determined in step E under Design of Recirculation tank or Chamber of this manual Figures 8 and 9 show two different by pass valves Both of the by pass valves can be constructed using the proper components or they may be purchased ready to install From by pass port of How cowimal Niimg ae d bushing we 4 a B increases Bypass float ball valve with 6 rubber ball A pel poet Wl plastic pipes with caps
6. below pump curve Z Septic tank tested for water tightness Z Owner issued operational manual Residual head at start up Programmable timer settings 34 of 35 Sanitary Permit Number Plan ID Number Parcel Tax Number Base of STPB Base of SFPB STFM pitch ISF INFORMATION ISF outside dimensions Orifice position Filter media source Force main length Force main diameter ELEVATION DATA DM amp PUMP INFORMATION Tie e FrictionLoss SystemHead As BuiltTDH E l System Demand ADMINISTRATIVE REVIEW No No No Revision to plans required Construction directive issued Construction order issued Date of directive Directive deadline Enforcement order date Enforcement order deadline Date compliance issued oo STFM Septic Tank Force Main STPB Septic Tank Pump Basin VRP Vertical Reference Point DEVIATIONS FROM APPROVED PLANS Date Installation Approved Inspector Signature 35 of 35
7. gal gal in inches Infiltration surface of sand filter Infiltrative surface area DWF 5 gpd ft gpd 5 gpd ft f Width and length of sand filter container Width of infiltrative surface infiltrative surface area chosen cell length f ft ft or Length of infiltrative surface infiltrative surface area chosen cell width ft ft ft 27 of 35 L Total number of distribution laterals Total number of distribution laterals quotient of width of distribution cell 2 rounded up to next whole number M Number of orifices in system Number of orifices Length of lateral orifice spacing x number of laterals ft orifices ft x orifices N Diameter of distribution lateral Diameter per Graph 1 using length of individual lateral ID O Minimum discharge rate of recirculation tank pump Discharge rate total number of orifices x 0 41 gpm orifice _ 8pm P Diameter of force main from recirculation tank pump Diameter size from Table 5 using minimum discharge rate of recirculation tank pump ID 28 of 35 IX A EXAMPLE WORKSHEET RECIRCULATING SAND FILTER SYSTEM WORKSHEET Design wastewater flow DWF One or Two family Dwelling DWF 150 gal bedroom x of bedrooms 150 gal bedroom x _4 __ of bedrooms _600 gal day Public facility DWE 1 5 x Sum of each wastewater flow per source per day gal day Recirculation tank liquid ca
8. public facilities gt 150 of estimated wastewater flow in accordance with Table 4 of this manual or s Comm 83 43 6 Wis Adm Code Forward flow Design wastewater flow DWF SAND FILTER MEDIA TANK Wastewater particle size lt 1 8 inch Distribution cell area per orifice Design loading rate DLR lt 5 gpd ft based on forward flow Dose frequency 24 to 48 times per day Every 30 60 minutes Volume of a single dose DWF x 2 3 x recirculation rate dose frequency Recirculation rate 3 1 to 5 1 Table 2 SIZE RECIRCULATION TANK Recirculation tank capacity gt 2 2 x DWF Reserve volume in recirculation tank or gt DWF 2 chamber Surge volume in recirculation tank or 2 2 3 DWF chamber By pass zone volume in recirculation tank 2 DWF or chamber Pump protection volume capacity in 2 Depth as required by pump recirculation tank or chamber manufacturer 4 of 35 Table 2 SIZE continued Total distribution cell area Spacing between lateral and side wall Y2 of spacing between laterals or 12 inches whichever is less Table 3 OTHER SPECIFICATIONS Treatment capability for BODs TSS and gt 90 removal for BOD and TSS Total N and lt 70 removal for Total N Piping material Meets requirements of s Comm 84 30 2 Wis Adm Code for its intended use Fabric cover Geotextile fabric meeting s Comm 84 30 6 g Wis Adm Code Distribution cell aggregate material Meets requirements of Comm 84 30 6
9. 2 of 35 Single dose volume 2 3 DWF x recirculation rate number of doses per day 24 48 5 Determine the elevation at which the by pass valve will open The minimum elevation at which the by pass valve opens equals the elevation above the bottom of the tank which will hold a volume equal to the DWF Elevation at which the by pass valve opens Elevation required in the tank to hold a volume of liquid equal to the DWF 6 Determine the reserve zone capacity of the recirculation tank or compartment The minimum reserve zone is determined by dividing the DWF by 2 Reserve zone capacity DWF 2 7 Determine the surge capacity of the recirculation tank The minimum surge capacity is determined by calculating the two thirds of the design wastewater flow Surge capacity DWF x 2 3 8 Determine the required elevation of the inlet invert of the recirculation tank or chamber The minimum elevation of the inlet invert is determined by dividing the sum of the required volumes of the by pass valve zone surge zone and reserve zones by the gallons per inch value of the tank Elevation of inlet invert by pass valve volume surge zone volume reserve zone volume gallons per inch of tank Step C Design of the Recirculating Sand Filter Component This section determines the required size of the distribution cell area as well as the dimensions for the complete sand filter component Figures 3 and 4 show cross sections of recirculat
10. Fig 8 By pass valve using float ball 20 of 35 r From by pass jori of flow contrel fitting a 2 4 24 bushing Fa pipe Float valve 4 3g pipe i sail Filmat Fig 9 By pass valve using float valve 12 Cover The cover over the distribution net work must extend to final grade and be of either wash aggregate or decorative rock All surface waters must be diverted away from the sand filter 13 Control panel The sand filter is dosed by timed doses The recirculation tank or chamber must provide for surge loading and surge reserve volumes CONSTRUCTION Procedures used in the construction of the recirculating sand filter system component are just as critical as the design of the component A good design with poor construction results in component failure Lay out the location and size of the recirculation tank sand filter and the soil distribution dispersal component and or its dose tank or chamber Determine where the force main from the recirculation tank will connect to the effluent distribution system of the sand filter component The size of the force main pipe is determined from the pressure distribution design and sizing requirements specified in this manual and sizing methods of either Small Scale Waste Management Project publication 9 6 entitled Uniform Distribution in Soil Absorption Fields or Dept of Commerce publication SBD 10573 P entitled Pressure
11. HEET RECIRCULATING SAND FILTER SYSTEM WORKSHEET A Design wastewater flow DWF One or Two family Dwelling DWE 150 gal bedroom x of bedrooms 150 gal bedroom x of bedrooms gal day Public Facility DWE 1 5 x Sum of each wastewater flow per source per day gal day B Recirculation tank liquid capacity Recirculation tank liquid capacity DWF x 2 2 gal x 2 2 gallons Selected tank size and manufacturer gallons tank manufactured by C Average gallons per inch of the recirculation tank Gallons per inch liquid capacity of tank gallons Liquid depth inches gal inches gal in D Elevation of low level emergency pump cut off alarm Elevation of cut off distance required by pump manufacturer inches _in E Volume of a single dose Dose volume 2 3DWE x recirculation rate dose frequency 24 to 48 times day gal dayx s ___ doses day gal dose 26 of 35 Distance from opening point of by pass valve to bottom of tank Distance DWF gallons per inch of tank capacity gal gal in inches Surge zone capacity Capacity DWF x 2 3 si gal x 2 3 ___ gallons Reserve zone capacity Capacity DWF 2 ___ gail 2 ___ gallons Distance from activation point of high water alarm to bottom of tank Distance Distance from opening point of by pass valve to bottom of tank surge zone capacity gal in value of recirculation tank inches
12. RECIRCULATING SAND FILTER SYSTEM COMPONENT MANUAL FOR PRIVATE ONSITE WASTEWATER TREATMENT SYSTEMS State of Wisconsin Department of Commerce Division of Safety and Buildings SBD 10628 P R 6 99 TABLE OF CONTENTS Page I Introduction and Specifications 3 Il Definitions 6 M Description and Principle of Operation 7 IV Design 8 V Construction 20 VI Operation Maintenance and Performance Monitoring 22 VII References 24 VII Worksheet 25 IX Example Worksheet 28 X Plan Submittal and Installation Inspection 31 Published on June 25 1999 by Dept of Commerce Division of Safety and Buildings Safety and Buildings Publication SBD 10628 P R 6 99 ADA Statement The Department of Commerce is an equal opportunity service provider and employer If you need assistance to access services or need material in an alternate format please contact the Department at 608 266 3151 or TTY 608 264 8777 2 of 35 I INTRODUCTION AND SPECIFICATIONS This Private Onsite Wastewater Treatment System POWTS component manual provides design construction inspection operation and maintenance specifications for a recirculating sand filter system component However these items must accompany a properly prepared and reviewed plan acceptable to the governing unit to help provide a system that can be installed and function properly Violations of this manual constitute a violation of chs Comm 83 and 84 Wis Adm Code The recirculating san
13. area e Benchmark and north arrow e Setbacks indicated as per appropriate code e Location information legal description of parcel must be noted e Location of any nearby existing component or well 32 of 35 Plan View Dimensions for Recirculating filter media filter distribution cell s Location of observation pipes Pipe lateral layout which must include the number of laterals pipe material diameter and length and number location and size of orifices Manifold force main locations with materials length and diameter of each Cross Section of Component Lateral elevation position of observation pipes dimensions and depths of aggregates and filter media and type of cover material such as geotextile fabric and depth if applicable Component Sizing For one and two family dwellings the number of bedrooms must be included For public facilities the sizing calculations must be included Tank and Pump Information Other All construction details for site constructed tanks Size and manufacturer information for prefabricated tanks Notation of pump or siphon model pump performance curve friction loss for force main and calculation for total dynamic head Cross section of tank chamber to include storage volumes connections for piping vents and electricity pump off setting dosing cycle and volume and location of vent and manhole Cross section of two compartments tanks or tanks install
14. cifications for electrical and mechanical components Names and phone numbers of local health authority component manufacturer or management entity to be contacted in the event of a failure Information on the periodic maintenance of the recirculating sand filter system including electrical and mechanical components E Performance monitoring must be performed on recirculating sand filter system components installed under this manual 1 The frequency of monitoring must be a At least once every six months after installation for the first two years Then once a year for the next to years Then once ever three years thereafter and b At times of problem complaint or failure F The minimum criteria addressed in performance monitoring of recirculating sand filter system components are 1 Type of use 2 Age of system 3 4 Mechanical malfunction within the component including problems with valves or Nuisance factors such as odors or user complaints other mechanical or plumbing components Material fatigue or failure including durability or corrosion as related to construction or structural design Neglect or improper use such as overloading the design rate poor maintenance of vegetative cover inappropriate cover over the recirculating sand filter system component or inappropriate activity over the recirculating sand filter component Installation problems such as improper materials or locat
15. d filter system component must receive influent flows and loads less than or equal to those specified in Table 1 When designed installed and maintained in accordance with this manual the recirculating sand filter component provides treatment of domestic wastewater The effluent from a recirculating sand filter system typically has monthly average values of 15 mg L for BODs 10 mg L for TSS 30 mg L for Total N and lt 10 cfu 100 ml for fecal coliform when inputs are within the range specified in Tables 1 to 3 Note Detailed plans and specifications must be developed and submitted for review and approval by the governing unit having authority over the plan for the installation Also a Sanitary Permit must be obtained from the department or governmental unit having jurisdiction See Section X for more details Table 1 INFLUENT FLOWS AND LOADS RECIRCULATION TANK Design wastewater flow DWF lt 2250 gal day from primary treatment tanks Monthly average value of Fat Oil lt 30 mg L and Grease FOG Monthly average value of five day lt 999 mg L Biochemical Oxygen Demand BOD Monthly average value of Total lt 150 mg L Suspended Solids TSS Monthly average value of Total lt 180 mg L Nitrogen TN 3 of 35 Table 1 INFLUENT FLOWS AND LOADS continued RECIRCULATION TANK continued Design wastewater flow DWF lt 150 gal day bedroom from one and two family dwellings Design wastewater flow DWF from
16. d ft 600 gpd 5 gpd ft 120 ft K Width and length of sand filter container Width of infiltrative surface infiltrative surface area chosen cell length 120 ft 16 ft 75 ft or Length of infiltrative surface infiltrative surface area chosen cell width ft ft ft 30 of 35 L Total number of distribution laterals Total number of distribution laterals quotient of width of distribution cell 2 rounded up to next whole number 7 5 2 _4 4 M Number of orifices in system Number of orifices Length of lateral orifice spacing x number of laterals 16 ft _2 orifices ftx _4 32 _ orifices N Diameter of distribution lateral Diameter per Graph 1 using length of individual lateral _3 4_ID O Minimum discharge rate of recirculation tank pump Discharge rate flow rate of lateral from table 5 x number of laterals 33 gpmx_4 _13 2 gpm P Diameter of force main from recirculation tank pump Diameter size from Table 5 using minimum discharge rate of recirculation tank pump 1 ID 31 of 35 X PLAN SUMBITTAL AND INSTALLATION INSPECTION A Plan Submittal In order to install a component correctly it is important to develop plans that will be used to install the component correctly the first time The following checklist may be used when preparing plans for review The checklist is intended to be a general guide Conformance to the list is not a guarantee of plan appr
17. e on the side of the underdrain pipe The collection pipe extends outside the sand filter container to the recirculation tank Filtered effluent collection aggregate A layer of stone aggregate meeting the specifications listed in Table 3 is placed in the bottom of the tank to a depth of at least equal to the top of the collection pipe The stone aggregate provides a means for the filtered effluent to flow to the collection pipe Pea gravel cover over filtered effluent collection stone aggregate and pipe A layer of pea gravel meeting the specifications listed in Table 3 is placed over the effluent collection stone aggregate and filtered effluent collection pipe to a depth of at least three inches The pea gravel acts a barrier so the filter media does not migrate into the collection stone aggregate and pipe Filter media A two foot layer of sand media meeting the specifications listed in Table 3 is placed on top of the pea gravel to provide filtration and treatment of the effluent The top of the filter media is leveled Distribution cell aggregate A two inch layer of stone aggregate meeting the specifications listed in Table 3 is placed on top of the pea gravel to spread the effluent out over the filter media 15 of 35 Distribution network The distribution network spreads the septic tank effluent as uniformly as possible over the sand filter surface The network consists of a manifold and laterals Typical design consists of a
18. ed in a series must include information listed above For design flows greater than 1000 gpd include the manufacturer model and location of a metering device which accurately meters the amount of effluent entering the component B Inspections Inspection shall be made in accordance with ch 145 20 Wis Stats and s Comm 83 26 Wis Adm Code The inspection form on the following two pages may be used The inspection of the component installation and or plans is to verify that the component at least conforms to specifications listed in Tables 1 3 of this manual 33 of 35 GENERAL INFORMATION Permit Holders Name VRP Elevation VRP Description Inspector Name amp License Dates Inspected CONTRACTOR INFORMATION Plumber Name TANK INFORMATION Manufacturer Gallons inch Electrician Name Excavator Name Tank Capacity Capacity of First Compartment Capacity of Second Compartment rs haz Inside height Alarm timer override ra r inches inches Timer off Red Off low level alarm Force main Diameter Inches Inches Inches e main ensin Measured from bottom of tank cover OPERATIONAL REVIEW STPB floats tested Yes No No SFPB floats tested No Z Distribution pipes flushed Yes No Ye no Ye fno off DTPB Recirculation tank Pump Basin SFPB Filter media Filter Pump Basin SFPB FM Filter media Filter Pump Basin Force Main Z As built TDH
19. f six inches is over the distribution network 22 of 35 3 Other specifications for materials and design A Filtered effluent discharge pipe The filtered effluent discharge pipe is installed to discharge the effluent to the distribution dispersal cell and recirculation tank All pipe penetrations shall be sealed water tight by the use of gaskets The filtered effluent pump discharge pipe is connected to the flow splitter fitting The flow splitter fitting shall be properly sized to allow 75 to 85 of the effluent to be discharged into the recirculation tank The discharge end of the flow splitter fitting shall be connected to a long turn tee that directs the wastewater to the by pass valve The discharge end of the long turn tee is connected to a pipe which discharges to the distribution dispersal cell by gravity or to a dose tank serving the distribution dispersal cell The bottom of the long turn tee is connected to a two inch diameter pipe that extends down to the by pass valve VI OPERATION MAINTENANCE AND PERFORMANCE MONITORING A The component owner is responsible for the operation and maintenance of the system The county department or POWTS service contractor may make periodic inspections of the components and effluent levels etc The owner or owner s agent is required to submit appropriate records routinely to the county or other appropriate jurisdiction and or the department B Design approval and site ins
20. f the filtered effluent is discharged into the recirculation tank The portion that is not discharged into the recirculation tank flows to soil distribution dispersal cell or a dose tank Physical entrapment increased retention time and conversion of pollutants in the wastewater are important treatment objectives accomplished under unsaturated conditions Some pathogens contained in the wastewater are eventually deactivated through filtering retention and adsorption by the filter media Figure 1 indicates the flow path of a recirculating sand filter system ea imil ee Sand filter tank 2 Recirculathom Hra Soll disnribution dispersal cell of dose tank Fig 1 Flow path of recirculating sand filter system 8 of 35 IV DESIGN A Size Sizing of the recirculating sand filter system must be in accordance with this manual The means of pressurizing the distribution network must provide equal distribution of influent over the distribution cell A pressurized distribution network sized using the charts and graphs contained in this manual and methods delineated in either Small Scale Waste Management Project publication 9 6 entitled Design of Pressure Distribution Networks for Septic Tank Soil Absorption System or Dept of Commerce publication SBD 10573 P entitled Pressure Distribution Component Manual for Private Onsite Wastewater Treatment Systems is acceptable B Recirculating Sand Filter System Compone
21. hwasher and or food waste grinder only Restaurant 24 hr kitchen waste only without dishwasher Patron seating space and or food waste grinder Restaurant 24 hr toilet waste 40 1 50 40 33 Restaurant 24 hr toilet and kitchen waste without Patron seating space dishwasher and or food waste grinder Restaurant 24 hr toilet and kitchen waste with Patron seating space dishwasher and or food waste grinder Restaurant dishwasher and or food waste grinder only Restaurant kitchen waste only without dishwasher and or Patron seating space food waste grinder Restaurant toilet waste Patron seating space Restaurant toilet and kitchen waste without dishwasher Patron seating space and or food waste grinder Restaurant toilet and kitchen waste with dishwasher Patron seating space 22 and or food waste grinder Retail store Patron 70 of total retail area 30 sq ft per patron School with meals and showers Classroom 25 students classroom S S 3 0 0 School with meals or showers Classroom 25 students classroom School without meals or showers Classroom 25 300 students classroom 6 5 Self service laundry toilet waste only Clothes washer Self service laundry with only residential clothes washers Clothes washer Swimming pool bathhouse May be high strength waste 11 of 35 Step B Design of the Recirculation Tank or Chamber This section determines the required liqu
22. id capacity and depth of the recirculation tank or chamber as well as the operation elevation of the by pass valve high water alarm and low level emergency pump cut off Figure 2 shows a cross section of a recirculation tank for a recirculating sand filter Forward flow path Filteced efihia ret discharge points _ Sunge zo Hy pass zone Pump shut off Imeni Figure 2 Cross section of recirculation tank 1 Determine the minimum liquid capacity of the recirculation tank or chamber The minimum liquid volume of the recirculation tank or chamber is equal to 2 2 times the design wastewater flow Minimum liquid capacity of recirculation tank or chamber 2 2 x DWF 2 Determine the gallons per inch of the tank or chamber selected for recirculation tank or chamber The gallons per inch of the tank or chamber equals the tank or chamber capacity divided by the liquid depth Gallons per inch of tank or chamber capacity in gallons liquid depth in inches 3 Determine the elevation of the low level emergency pump cut off The elevation of the low level emergency pump cut off is the minimum required liquid level above base of pump as specified by the pump manufacture 4 Determine the volume of a single dose The volume of a single dose is determined by multiplying the 2 3 of the DWE by the recirculation rate then dividing by the number of doses per day Number of doses per day must between 24 and 48 1
23. ilter system component described in this manual Formula 2 DWF 1 5 x Sum of each wastewater flow per source per day from Table 4 9 of 35 Table 4 eye Public Facility Wastewater Flows Source Unit Estimated Wastewater Flow gpd 3 Campground or Camping Resort Space with sewer connection 30 CmpemleConenetowt eer seer tang 5 Dining hall kitchen waste only without dishwasher and or food waste grinder Dining hall toilet and kitchen waste without dishwasher 5 and or food waste grinder Dining hall toilet and kitchen waste with dishwasher 7 and or food waste grinder Drive in restaurant all paper service with inside seating Patron seating space 0 Drive in restaurant all paper service without inside Vehicle space seating Vehicle space Employees total all shifts Employee Floor drain not discharging to catch basin Gas station convenience store Patron minimum 500 patrons Gas station with service bay Patron Patron Service bay Service bay 50 135 65 Medical office building Doctors nurses medical staff Person 50 Office personnel Person 13 Patients Person Migrant labor camp central bathhouse Employee Mobile Home Manufactured home served by its own Bedroom POWTS Mobile home park Mobile home site May be high strength waste 10 of 35 Table 4 Public Facility Wastewater Flows continued Source Unit Estimated Wastewater Flow gpd Restaurant 24 hr dis
24. in feet Where h Feet of head C Friction factor from Hazen Williams 145 for plastic pipe gpm gallons per minute d Nominal pipe size 18 of 35 10 Observation pipe s At least two observation pipes are placed extending from the top of the filter media stone aggregate interface to finish grade to monitor for ponding and or formation of a clogging mat The pipes must be secured and have perforations in the bottom 4 inches Figure 5 shows two examples of observation pipes a Water tight cap _ 4 min dia Panforations 4 k ht a r Water Closet Collar Barca min dia Fig 5 Observation pipes Discharge of the sand filter effluent The sand filter effluent drains by gravity through the recirculation tank The filtered effluent drain pipe is installed with a means of diverting 75 to 85 of the effluent to the recirculation tank and with a low liquid level by pass valve to divert all of the effluent into the recirculation tank during low or no flow conditions The filtered effluent drain pipe diverts 75 to 85 of the effluent into the recirculation tank by the use of a special flow splitter fitting The flow splitter fitting consists of components as shown in figure 6 The inner wall is a circular piece made of material that is the same as the fitting The inner wall is solvent cemented in place and additional support is provided by the drain pipe Four to six pipes of the same size
25. ion 24 of 35 8 Pretreatment component maintenance including dosing frequency structural integrity groundwater intrusion or improper sizing 9 Pump chamber maintenance including improper maintenance infiltration structural problems or improper sizing 10 Pump malfunction including dosing volume problems pressurization problems breakdown burnout or cycling problems G Reports are to be submitted in accordance to Ch Comm 83 Wis Adm Code VI REFERENCES David Venhuizen 1997 A Minnesota regulator s Guide to the Venhuizen Standard Denitrifying Sand Filter Wastewater Reclamation System James C Converse 1997 recirculating Sand Filters for On Site Treatment of Domestic Wastes T R Bounds P E and Design Staff Orenco Systems Inc 1994 Design Criteria for Recirculating Sand Filters Ted L Loudon Design of Recirculating Sand Filters ASAE proceedings of the Seventh International Symposium on Individual and Small Community Sewage Systems Jeffrey L Ball P E and Grant D Denn Design of recirculating Sand Filters using a Standardized Methodology David Venhuizen P E 1997 Sand Filter Drip Irrigation Systems Solve Water resources Problems ASAE proceedings of the Eighth International Symposium on Individual and Small Community Sewage Systems David Venhuizen P E 1996 Intermittent Sand Filters New Frontiers for an Ancient Art 25 of 35 VII WORKS
26. ion sand filters that can be used in accordance with this manual 13 of 35 Observation plpa Sione aqyregate or decorative rock Finish grade Sione aggregaic Baciti material Liner frame Bedding Fig 3 Formed sand filter Observation pipe Stone aggqreate or decorative rock Finish grade Simme agyreate Stone aggreste Wmderdrabn Fig 4 Sand filter in a tank Determine the distribution cell area The minimum distribution cell area is calculated by dividing the design wastewater flow by a design loading rate of 5 gpd ft Distribution cell area DWF DLR of 5 gpd ft 14 of 35 Sand filter container The sand filter container is a watertight open top vessel The container shall meet requirements of s Comm 84 25 Wis Adm Code or a watertight container constructed of a durable 30 mil PVC or 45 mil EPDM liner is required The container shall be designed to accommodate all the necessary components Components include but are not limited to infiltrative surface required for the system cover distribution system filter media collection system and a means of discharging the collected effluent by gravity The container must be located to prevent surface and groundwater from entering the container Filtered effluent collection A 4 underdrain pipe with slots or holes is placed on the bottom of the container to collect the filtered effluent Installation orientation of the slots or holes must b
27. nt Design Detailed plans and specifications must be developed reviewed and approved by the governing unit having authority over the plan for the installation A Sanitary Permit must also be obtained from the department or governmental unit having jurisdiction Design of the recirculating sand filter system component is based on the estimated wastewater flow It must be sized such that it can accept the daily wastewater flow at a rate that will provide treatment Design of the recirculating sand filter system includes three steps which are A calculating the design wastewater flow B design of the recirculation tank or chamber and C design of recirculating sand filter component Step A Design wastewater flow One and two family dwellings The infiltrative surface size for one and two family dwelling application is determined by calculating the designed wastewater flow DWF To calculate DWF use formula 1 Formula 1 DWE 150 gallons bedroom day Public facilities Infiltrative surface size for a public facility application is determined by calculating the DWF using formula 2 Public facility estimated daily wastewater flows are listed in Table 4 Facilities that are not listed in Table 4 are not included in this manual Many commercial facilities have high BODs TSS and FOG fats oil and grease which must be pretreated in order to bring their values down to an acceptable range before entering into the recirculating sand f
28. oefficient CU lt 2 0 Sand Maximum minimum Gradation Sand media sieve specifications Sieve Size Passing 3 8 100 4 60 100 8 7 75 16 0 5 30 0 3 50 0 2 In accordance with ch Comm 83 Wis Adm Code In accordance with ch Comm 83 Wis Adm Code Installation inspection Management Il DEFINITIONS Definitions unique to this manual are included in this section Other definitions that may apply to this manual are located in ch Comm 81 of the Wis Adm Code or the terms use the standard dictionary definition A By pass valve means a valve that opens to allow effluent from the filter media to be discharged totally to the recirculation tank during low or no wastewater flow conditions B By pass zone means a volume of liquid in a recirculation tank that is designed to provide the filter with sufficient liquid to keep the filter active when the recirculation tank is receiving little or no flow from a facility C Infiltrative surface means a top layer of media that receives effluent from a distribution network D Recirculation rate means the portion of the wastewater effluent that is delivered back into the system compared to the wastewater effluent that is not delivered back into the system E Recirculating sand filter system means an onsite wastewater treatment component which contains a recirculation tank and an effluent filtering comp
29. onent which treats wastewater by passing it through the system more than once 7 of 35 F Recirculation tank means the tank which receives effluent from a septic treatment tank and sand filter and doses the sand filter M DESCRIPTION AND PRINCIPLE OF OPERATION POWTS recirculating sand filter system component operation consists of a recirculation tank or chamber and a fixed film aeration process unit in which wastewater passes through a porous media The system reduces BODs TSS Nitrogen as Total N and Fecal coliform BODs is reduced by supplying oxygen to the wastewater stream TSS is reduced through settling and filtration Nitrogen as Total N is reduced by converting ammonia to nitrate then converting nitrate to nitrogen gas Fecal coliform is reduced by attachment and die off of the bacteria to the media as the wastewater flows through the porous media Oxygen diffuses into the thin film of water as air passes through the media by convection due to temperature differences Air is also drawn in as the wastewater moves through the media The component is designed to encourage passive air movement through the unit Effluent is dosed from the recirculation tank to the filter The filter is of such coarse material that orifices may only cover four square feet of surface area The filtered effluent is then collected and flows by gravity to the recirculation tank Depending on the liquid level in the recirculation tank a portion or all o
30. oval Additional information may be needed or requested to address unusual or unique characteristics of a particular project Contact the reviewing agent for specific plan submittal requirements which the agency may require that are different than the list included in this manual General Submittal Information e Submittal of additional information requested during plan review or and questions concerning a specific plan must be referenced to the Plan Identification indicator assigned to that plan by the reviewing agency e Plans or documents must be permanent copies or originals Forms and Fees e Application form for submittal provided by reviewing agency along with proper fees set by reviewing agent e Onsite verification report signed by the county or appropriate state official Documentation e Architects engineers or designers must sign seal and date each page of the submittal or provide an index page which is signed sealed and dated e Master Plumbers must sign date and include their license number on each page of the submittal or provide an index page which is signed sealed and dated e Three completed sets of plans and specifications clear permanent and legible submittals must be on paper measuring at least 8 1 2 by 11 inches Plot Plan e Dimensioned plans or plans drawn to scale scale indicated on plans with parcel size or all property boundaries clearly marked e Slope directions and percent in component
31. pacity Recirculation tank liquid capacity DWF x 2 2 _ 600 gal x 2 2 1320 gallons Selected tank size and manufacturer _ 1350 gallons tank manufactured by Best Tanks in the World Inc Average gallons per inch of the recirculation tank Gallons per inch liquid capacity of tank gallons Liquid depth inches 1350 gal _50 5__ inches _ 26 74 gal in Elevation of low level emergency pump cut off alarm Elevation of cut off vertical distance required by pump manufacturer inches Volume of a single dose Dose volume 2 3DWE x recirculation rate dose frequency 24 to 48 times day 400 _ gal day x 5 5 1 recirculation rate _24 doses day 83 33 gal dose 29 of 35 F Distance from opening point of by pass valve to bottom of tank Distance DWF gallons per inch of tank capacity 600 gal _26 74 gal in 22 44 inches G Surge zone capacity Capacity DWF x 2 3 _600 galx2 3 400 gallons H Reserve zone capacity Capacity DWF 2 _600 gal 2 300 _ gallons I Distance from activation point of high water alarm to bottom of tank Distance Distance from opening point of by pass valve to bottom of tank surge zone capacity gal in value of recirculation tank 22 44 in 400 gal 300 gal _ 26 74 gal in 22 44 in 26 18 in 48 26 inches Invert elevation of selected tank 50 5 inches J Infiltration surface of sand filter Infiltrative surface area DWF 5 gp
32. pections before during and after the construction are accomplished by the county or other appropriate jurisdictions in accordance to Ch Comm 83 of the Wis Adm Code C Other routine and preventative maintenance aspects are 1 The effluent filter in the septic tank is to be inspected and maintained at least every six months The septic and recirculation tanks are to be inspected and maintained at least every three years If the scum and sludge occupies 1 3 of the tanks volume the tank shall be pumped and its contents properly disposed of If the tank is not pumped at this time it shall be pumped when the scum and sludge occupies 1 3 of the tanks volume Inspections of recirculating sand filter component performance is required at least every six months for the first two years Then once a year for the next two years 23 of 35 4 5 Then once every three years thereafter These inspections include checking the liquid levels in the observation pipes and examination for any seepage around the filter The pump frequency and run time are to be check at least every six months A good water conservation plan within the house or establishment will help assure that the filter system will not be overloaded D User s Manual A user s manual is to accompany the recirculating sand filter component The manual is to contain the following as a minimum l 2 BF Diagrams of all system components and their location Spe
33. pipe with slots or holes by placing it on the bottom of the sand filter tank and connecting it to solid wall pipe prior to exiting the tank The installation orientation of the slots or holes must be on the side of the underdrain pipe The opening in the tank wall shall be sealed by use of a gasket Place a four inch layer of stone aggregate meeting the specifications of Table 3 in the bottom of the filter component tank Place a three inch layer of pea gravel meeting the specifications of Table 3 over the underdrain effluent collection pipe and stone aggregate Place 24 inches of filter media meeting the specifications listed in Table 3 on top of the pea gravel Install the required observation pipes with the bottom four inches of the observation pipes perforated Installations of all observation pipes include a suitable means of anchoring See figure 3 Place two inches of stone aggregate meeting the specifications of Table 3 over the filter media Install the valve boxes cleanouts and pressure distribution network with laterals sloped at least 1 inch toward the manifold Test the system to adjust the head pressure to at least 5 feet at the distal orifice Install the orifice shields or half pipe M Place at least two inches of stone aggregate meeting the specifications of Table 3 over the distribution laterals Cover the sand filter with additional aggregate such as washed rock or decorative rock until a maximum o