SVP-3DS User Manual

image

Contents

1. SVP 3DS DART 3 D Scanner X Y User Manual Revision 2 Document 7 5 056 io sense Your source for open air mass spectrometry IonSense Inc 999 Broadway Suite 404 Saugus MA 01906 Copyright 2005 2015 by lonSense Inc All rights reserved The information in this document has been carefully checked and is believed to be reliable However no responsibility is assumed for inaccuracies Statements in the document not intended to create any warranty expressed or implied Specification and performance characteristics of the hardware and software described in the manual may be changed at any time without notice lonSense Inc reserves the right to make changes in any product herein in order to improve reliability design or function lonSense does not assume any liability arising out of application or use of any product or circuit described nor does it cover any license under its patent rights or the rights of others The apparatus and application of the apparatus described in this document is protected by US Patent Number 6 949 741 and used under license additional patents pending All trademarks are properties of their respective owners Table of Contents Scope of Delivery Standard System Components Configuration Dependent Components Functional Description Safety Installation X Rail Installation Attaching the XY 2nd Rail Mount Slide Y Rail Installation Mounting the DART SVP Source on the SVP 4
2. 345 Range 0 500 Increment 1 Fixed not user adjustable Start Position 43 8mm Y and X speed when not scanning 10mm sec Troubleshooting lf the methods do no run correctly with respect to alignment of the sampling areas and the exit of the DART source please read the following statements Please check that the carriage positions for both the X and Y rails are correct The measurements are taken from the edge of the linear rail carriage to either the end of the motor for the Home switch position or to the end of the linear rail for the Limit switch position Refer to page 15 in the DART SVP Hardware and Network Installation Manual for a visual explanation of this measurement X Rail Measurements Home switch 56 mm Limit switch 134 5 mm Y Rail Measurements Home switch 56 mm Limit switch 44 mm Maintenance No special maintenance is required for the X Y scanner Replacement Parts SI 90XX XX Ceramic Tubes see the VAPUR Interface Ceramic Tubes Reference Sheet 7 5 038 for lengths JG10019 Graphite Vespel Ferrule Revision History Revision History DCR Description of Change Effective Date Initial Release 11 11 2013 2 200 Updated format to match DART 4 09 2015 SVP hardware manual including new sections scope of delivery functional description safety troubleshooting maintenance and replacement parts Updated the photos and descriptions in the installation section to show the m
3. 5 A Module Mounting the 3D Scanner Adjustment Module Installing the Ceramic Tube Linear Rail Settings Operation X Y Scanner Method Troubleshooting Maintenance Replacement Parts Revision History KABA 12 15 16 17 18 Scope of Delivery This chapter lists the components of the 3 D Scanner X Y Figure 1 Scope of Delivery Standard System Components 1 JVL 2066 A 3D Scanner Adjustment Module 2 JVL 2064 A Tray Holder Assembly 3 JG10044 Ceramic Cap 32 5 Deg 4 SHSC_SS188 M3 _ 10mm Bag of M3x10 Screws Qty 16 5 N A XY 2 Rail Mount Slide see below for details 6 N A Linear Rail see below for details 7 23992 00 Cable V2 0 Linear Rail Driver not pictured installed inside controller 8 JG10019 Graphite Vespel Ferrule not pictured Configuration Dependent Components 1 SI 90XX XX Ceramic Tubes see the VAPUR Interface Ceramic Tubes Reference Sheet 7 5 038 for lengths 2 HW10046 47 Left Right Handed Rail motorized 100mm Movement 3 JVL 2068 2068 R Left Right Handed XY 2 Rail Mount Slide NOTE Left or right hand orientation is dependent on the Mass Spectrometer 4 SSS Functional Description Figure 2 3 D Scanner X Y right handed configuration shown The 3 D Scanner X Y enables continuous scanning across a 2 dimensional rectangular space Definitions X Rail The X Rail is the 300 mm rail that comes with the DART SVP Y Rail The Y Rail is the 100 mm rail that comes with th
4. e 3 D Scanner XY Rail Carriage The Rail Carriage is cre ppp the part of the linear rail that moves and has threaded holes for modules to attach TRail Carriage Figure 3 Rail with Rail Carriage highlighted Y Rail Cradle The Y Rail Cradle is the part of the XY 2nd Rail Mount Slide that holds the Y Rail Y Rail Cradle Figure 4 XY 2nd Rail Mount Slide with Y Rail Cradle highlighted Safety Refer to the SVP Hardware and Network manual for safety warnings regarding operating the DART Installation X Rail Installation The DART SVP source has an X Rail Cradle Simply place the linear rail directly into the cradle on the baseplate The rail will click into place when it is correctly positioned Lock the rail into place using a 1 5 mm Allen wrench to tighten the two set SCrews Figure 5 DART SVP Source with X Rail Attached Attaching the XY 2nd Rail Mount Slide Place the XY 2nd Rail Mount Slide on top of the X Rail Carriage Using four M3x5 screws and the 2 5mm Allen wrench loosely secure the XY 2nd Rail Mount Slide onto the X Rail Carriage aligning it so that the Y Rail Cradle covers the X Rail motor o Ce ny RA 3 heat ee eee D Car eee 2e APE Re ee Figure 6 XY 2nd Rail Mount Slide with the cradle covering the X Rail Motor PN 27 NT Tighten the two 1 5mm set screws on the side of the XY 2nd Rail Mount Slide facing the DART SVP for good alignment and then finish tighteni
5. gure 11a and 11b 3 D Scanner X Y linear rail settings rails HW10029 amp HW10046 Lua ur Ed Operation X Y Scanner Method Method Description This method enables continuous scanning across a User Defined 2 Dimensional rectangular space Maximum 109mm x 61mm Minimum 1mm x 5mm It will scan from left to right in right hand configuration or vice versa in left hand configuration for each scan at a user defined speed and temperature Prior to each row scan a contact closure signal will be sent represented by the in the figure below t wo a p a j Figure 12 X Y Scanner Method scan path Parameter Definitions User Defined Sample Count Number of samples that will be run Default 11 Range 1 Sample Count Maximum Increment 1 Sample Count Maximum Y Length 4 6mm Y Spacing lon Mode Default Positive Other option Negative Heater Temperature C The set temperature for the DART heater Default 350 Range 0 500 increment 1 Heater Wait time sec The desired amount of time at the beginning of each run to allow for the ionization gas flow and temperature to stabilize A minimum of 30 seconds is recommended Default 30 Range 1 65563 18 hours Increment 1 Contact Closure Delay sec The amount of time spent sitting between samples to give time for contact closure signals and to provide some temporal resolution in the chromatogram Default 5 Range 1 65563 18 hou
6. ner Adjustment Module for proper alignment and then finish by completely tightening the four 2 5mm hex screws on the top of it f 3 S SS Arey lt e 7 AVI EA a s 4 k s A lt sty D ae Ca eS oe sA erat M A me br e A se ess fr oa 5 o Figure 10 3D Scanner Adjustment Module with set screws circled in red Installing the Ceramic Tube Insert the longer ceramic tube into the VAPUR inlet taking care to leave a 2mm gap between the end of the ceramic tube and the API inlet Refer to the specific Vapur Flange Manual for the mass spectrometer that the DART SVP is being installed on for more details Linear Rail Settings Before running the method be sure the Linear Rail software settings are correct lf they aren t the methods won t run properly To check click on the Settings tab in the software open both Linear Rail 1 X and Linear Rail 2 Y e For systems with linear rail part numbers HW10029 and HW10046 left should be selected for both Motor Location and Sample From e For systems with linear rail part numbers HW10039 and HW10047 right should be selected for both Motor Location and Sample From a A A g G T i f N Settings Motor Location m i Len Motor Location Left Sample From ee P Lett Set Target 0 00 Target Position mm 0 00 i 7 000 L Target Position Use Current Position Target Position Lise Current Position il th or Fi
7. ng the four 2 5mm screws on top of the XY 2nd Rail Mount Slide to finish the attachment ehh EA Figure 7 XY 2nd Rail Mount Slide with Set Screws Circled in Red Y Rail Installation Slide the non motor end of the rail into the cradle leaving it so the end of the rail is flush with the end of the XY 2nd Rail Mount Slide Using the 1 5mm Allen wrench tighten the two set screws to lock the rail in place Vas KA JL Late Piven Z eA COU Mer ie at U LIEU de tS SLI Ea 72 ke ame y A 4 lled with set screw x Se Sr A Er SA Lis he PR H circled in re me 4 ye HAINE PS Bia JA Figure 8 Y Rail insta Mounting the DART SVP Source on the SVP 45A Module Pull the DART SVP source housing all of the way back from the mass spectrometer inlet and remove the ceramic tube from the VAPUR interface Remove the DART SVP source from the baseplate by unscrewing the thumb Screw Attach the DART SVP source to the SVP 45A Module with the DART SVP source thumb screw Attach the SVP 45A module to the baseplate with the thumb screw on the SVP 45A module See figure 9 on the next page for reference Figure 9 Source with SVP 45A module Mounting the 3D Scanner Adjustment Module Place the 3D Scanner Adjustment Module on the Y Rail Carriage and loosely secure it using four M3x10 hex screws Using a 1 5mm Allen wrench tighten the two set screws on the back side of the 3D Scan
8. ost recent version of the product Updated the operation section with method descriptions from the method definition documents
9. rs Increment 1 X Sample Speed mm sec The Speed of the X rail when moving from sample to sample across the plate Default 2 0 Range 0 2 10 Increment 0 1 X Y Scanner A method thal enables scanning continuously across User Defined 2 Dimensional rectangular space It will scan from Left to right in right hand configuration or vice versa in lett hand configuration for each scan at a user defined speed Sample Count 11 lon Mode Positive Temperature c 350 Heater Wait Time sec 30 Contact Closure Delay sec 5 X Sample Speed msec 20 X Length imm 100 Y Length mm 60 Y Spacing imm 5 Shutdown State Standby Standby Temperature c 345 Figure 13 X Y Scanner Method Parameters X Length mm X_dimesional_object_size The size of the object or scanning area in the X dimension Default 100 Range 1 109 increment 1 Y Length mm Y_dimesional_object_size The size of the object or scanning area in the Y dimension Default 60 Range 5 61 increment 1 Y Spacing mm Y spacing between rows Default 5 Range 2 5 Y Length 4 6 Increment 1 Shutdown State The system can be kept in run or standby mode for repeated use or automatically shut down at the end of the analytical run Default Standby Other options Off Run Standby Temperature C If the system is kept in run or standby mode this temperature will be maintained It should be a little less than the start temperature Default