Home

USER MANUAL Stand Alone FOM Card Chassis SAC-1-AC

image

Contents

1. FIDER fiberplex com 301 604 0100 7 Figure 1 SAC 1 AC Front Face O Smoked Glass Face Plate Allows viewing of FOM status display panel and protects interior from dust and foreign object intrusion Rear Indicators Connections Figure 2 SAC 1 AC Rear Face 2 Standard IEC 320 Power Inlet For detachable power cord included FOM Mounting Holes Captive screws on FOM rear face secure here Internal Edge Connector Mates with FOM gold finger edge connectors Power Reguirements amp FOM Installation The SAC 1 AC power supply module accepts voltages from 100 240 VAC 50 60 Hz Maximum power consumption is approximately 16W for the FOMs with the greatest current draw The chassis power supply is fused internally no user serviceable fuse may be accessed for replacement Although the FOM cards are designed and rated for hot swap capability it is optimal practice to insert the module into the chassis prior to the application of AC power The FOM installation is shown below Figure 3 Installing a FOM Card into the SAC 1 AC Surface Mount Configuration The SAC 1 AC can optionally be surface mounted on any flat surface such as closet wall rack wall or even the side of a desk All of the parts necessary for surface mounting are included in the package 1 Attach the Surface Mounting Flange 118462 to each side of the bottom of 1 S
2. TECHNOLOGIES LLC Fiberplex USER MANUAL Stand Alone FOM Card Chassis SAC 1 AC Warning for Your Protection Read these instructions Keep these instructions Heed all warnings Follow all instructions Do not use this apparatus near water Clean only with a dry cloth Do not block any of the ventilation openings Install in accordance with the manufacturer s instructions ou DOB WN PB Do not install near any heat sources such as radiators heat registers stoves or other apparatus including amplifiers that produce heat 9 Do not defeat the safety purpose of the polarized or grounding type plug A polarized plug has two blades with one wider than the other A grounding type plug has two blades and a third grounding prong The wide blade or the third prong is provided for your safety If the provided plug does not fit into your outlet consult an electrician for replacement of the obsolete outlet 10 Protect the power cord from being walked on or pinched particularly at plugs convenience receptacles and the point where they exit from the apparatus 11 Only use attachments accessories specified by the manufacturer 12 Use only with the cart stand tripod bracket or table specified by the manufacturer or sold with the apparatus When a cart is used use caution when moving the cart apparatus combination to avoid injury from tip over 13 Unplug this apparatus during lightning storms or when unu
3. AC may be rack wall or desktop mounted utilizing the included components of the SAC 1 Mounting System e Possible bracket configurations are e Mounting to a desktop wall or similar surface e Rack mounting in a single installation occupying 1U of vertical space e Rack mounting in a dual configuration occupying 1U of vertical space Key Features Clear face plate allows safe viewing of the FOM status display while the module remains protected e Power entry and FOM interface cables are located at the rear of the unit e Mounting configuration requires no disassembly of the chassis e Cooling airflow is passive for silent operation Getting Started Initial Inspection Immediately upon receipt inspect the shipping container for damage The container should be retained until the shipment has been checked for completeness and the eguipment has been checked mechanically and electrically If the shipment is incomplete if there is mechanical damage or if the unit fails to operate notify FiberPlex and make the shipping materials available for the carrier s inspection Chassis Mounting Mount the chassis using the included bracket system All fasteners necessary for the various installation options are included Ensure that space exists below and above the ventilation slots at the installed position The chassis should be located in an environment where an ambient temperature between 0 and 50 C can be maintained Front Indicators
4. unit Condensation may not be present during operation If the unit is installed in a location subject to large variations of ambient temperature e g in an OB van appropriate precautions must be taken Unobstructed air flow is essential for proper operation Ventilation openings of the unit are a functional part of the design and must not be obstructed in any way during operation e g by objects placed upon them placement of the unit on a soft surface or improper installation of the unit within a rack or piece of furniture The unit must not be unduly exposed to external heat sources direct sunlight spot lights Ambient Temperature Units and systems by FiberPlex are generally designed for an ambient temperature range i e temperature of the incoming air of 5 40 C When rack mounting the units the following facts must be considered The permissible ambient temperature range for operation of the semiconductor components is O C to 70 C commercial temperature range for operation The air flow through the installation must allow exhaust air to remain cooler than 70 C at all times Average temperature increase of the cooling air shall be about 20 C allowing for an additional maximum 10 C increase at the hottest components If the cooling function of the installation must be monitored e g for fan failure or illumination with spot lamps the exhaust air temperature must be measured directly above th
5. AC 1 AC using 4 Flat Head Machine Screws as shown 2 screws on each flange Pan Head Wood Screws x4 2 Mount completed assembly on surface using supplied Wood Screws Part Number 118462 Surface Mounting Flange Flat Head Machine Screws x4 Single Rack Mount Configuration co Tiberi Eh All the parts necessary to mount a SAC 1 AC in a 1U rack space are included in the package 1 Attach the Small Rack Mount Ear 118451C to the SAC 1 AC using 4 Flat Head Machine Screws as shown 2 screws on top and 2 on the bottom 2 Attach the Large Rack Mount Ear 118450C to the opposite side using 4 Flat Head Machine Screws as shown 2 screws on top and 2 on the bottom 3 Mount the complete assembly into a standard 19 rack using customer supplied rack screws Flat Head Machine Screw x8 Sa g Part Number 118450C Large Rack Mount Ear LS Part Number 118451C Small Rack Mount Ear Dual Rack Mount Configuration DN Fer FREE epson 20100507 Marion 51 LS Half of the parts necessary to mount 2 SAC 1 AC in a 1U rack space are included in each SAC 1 AC package Together all parts needed are supplied 1 Attach the Small Rack Mount Ear 118451C to the right side of 1 SAC 1 AC using 4 Flat Head Machine Screws as shown 2 screws on top and 2 on the bottom 2 Attach another Small Rack Mount
6. Ear 118451C to the left side of the otherSAC 1 AC using 4 Flat Head Machine Screws as shown 2 screws on top and 2 on the bottom 3 Attach the Binding Plate 118473 to the right SAC 1 AC using 4 Flat Head Machine Screws as shown 2 screws on top and 2 on the bottom 4 _ Push the 2 SAC 1 AC together and install the 4 Flat Head Machine Screws in the remaining holes on the Binding Plate as shown 2 screws on top and 2 on the bottom 5 Mount the complete assembly into a standard 19 rack using customer supplied rack screws Flat Head Machine Screw CODEN Part Number 118473 A Binding Plate x2 YN Part Number 118451C Small Rack Mount Ear x2 Specifications All units are Inches mm 7 00 177 8 8 00 203 2 1 21 30 7 be exe o DDnnnnnnnnannn U U VV SA c y 11 97 304 0 A n D UUU JUL 7 36 187 0 Figure 4 SAC 1 AC Dimensions PHYSICAL SPECIFICATIONS Length Width Height Weight 11 97 in 304mm 8in 203mm 1 21in 31mm 2 lb 0 9 kg Case Dimensions 1U ELECTRICAL SPECIFICATIONS Power Reguirement Voltage Range VAC Power Consumption W 12 16 Envi
7. e modules at several places within the enclosure Grounding and Power Supply Grounding of units with mains supply class equipment is performed via the protective earth PE conductor integrated in three pin Phoenix connector Units with battery operation lt 60 V class lll eguipment must be earthed separately Grounding the unit is one of the measures for protection against electrical shock hazard dangerous body currents Hazardous voltage may not only be caused by defective power supply insulation but may also be introduced by the connected audio or control cables This eguipment may reguire the use of a different line cord attachment plug or both depending on the available power source at installation If the attachment plug needs to be changed refer servicing to gualified personnel Warranty Service and Terms and Conditions of Sale For information about Warranty or Service information please see our published Terms and Conditions of Sale This document is available on fiberplex com or can be obtained by reguesting it from clients fiberplex com or calling 301 604 0100 Disposal Disposal of Packing Materials The packing materials have been selected with environmental and disposal issues in mind All packing material can be recycled Recycling packing saves raw materials and reduces the volume of waste If you need to dispose of the transport packing materials recycling is encouraged Disposal of Used Eguipme
8. nt Used eguipment contains valuable raw materials as well as substances that must be disposed of professionally Please dispose of used eguipment via an authorized specialist dealer or via the public waste disposal system ensuring any material that can be recycled has been Please take care that your used eguipment cannot be abused After having disconnected your used eguipment from the mains supply make sure that the mains connector and the mains cable are made useless Disclaimer The information in this document has been carefully checked and is believed to be accurate at the time of publication However no liability is assumed by FiberPlex for inaccuracies errors or omissions nor for loss or damage resulting either directly or indirectly from use of the information contained herein Hardware Contents In addition to the SAC 1 AC chassis and power cord the following hardware parts are included to facilitate all of the possible mounting options for the SAC 1 AC Please inspect your package to ensure all pieces are available IEC Power Cord Part Number 118450C Large Rack Mount Ear Part Number 118451C Small Rack Mount Ear Part Number 118473 Binding Plate Part Number 118462 Surface Mounting Flange Flat Head Machine Screw V Cay x8 Introduction The FiberPlex SAC 1 AC is a standalone FOM card chassis providing power enclosure and secure mounting for a single Fiber Optic Module Each SAC 1
9. ronmental Storage Temperature C 40 85 Operating Temperature C 0 50 ber pilex TECHNOLOGIES LLC 18040 412 Guilford Rd Annapolis Junction MD 20701 UMSAC1 fiberplex com clients fiberplex com 301 604 0100 150105
10. sed for long periods of time 14 Refer all servicing to qualified service personnel Servicing is required when the apparatus has been damaged in any way such as power supply cord or plug is damaged liquid has been spilled or objects have fallen into the apparatus the apparatus has been exposed to rain or moisture does not operate normally or has been dropped The apparatus shall not be exposed to dripping or splashing No objects filled with liquids such as vases shall be placed on the apparatus WARNING To reduce the risk of fire or electric shock do not expose this apparatus to rain or moisture General Installation Instructions Please consider these general instructions in addition to any product specific instructions in the Installation chapter of this manual Unpacking Check the equipment for any transport damage If the unit is mechanically damaged if liquids have been spilled or if objects have fallen into the unit it must not be connected to the AC power outlet or it must be immediately disconnected by unplugging the power cable Repair must only be performed by trained personnel in accordance with the applicable regulations Installation Site Install the unit in a place where the following conditions are met The temperature and the relative humidity of the operating environment must be within the specified limits during operation of the unit Values specified are applicable to the air inlets of the