Home

A- GPRS1090 User`s Manual

image

Contents

1. Information 2010 7 31 15 16 11 Start successful Clear Record 2010 7 31 15 16 11 Server Listen Port 8000 the maximum number of allowed connections 100 Save Record Look over record 19 O Beijing ART Technology Development Co Ltd Chapter 5 Application Introduction 5 1 Protocol Transmission 5 1 1 Configuration Settings 1 First of all select Agreement transfer of transfer mode 2 DNS of Server DNS1 and server DNS2 has been set if need we can change it Default settings are DNS1 211 136 17 107 DNS2 202 106 0 20 3 Master data center IP uses the public IP if we use the main data center domain name then the current item must be empty Note the public network IP address changes every day so it needs to be updated 4 Main data center domain we can use software to application a domain name by a third party to manage the domain name it is more convenient for us Note The main data center IP must be set to empty when we use the domain name to connect 5 Main data center port No The computer that is using ARTServer exe application needs to open a port number and the port number is set in the current item 6 Select TCP mode of Main Data Center link Mode GPRS Configuration Tool U6 81 19 Local COM Configur B COM COM1 v Device ID 149241003604875 BaudRate 1115 2kbps Device name ARTDTUOL Data Bit 8 SIM card number 15810687274
2. SIM Card Number PHON Mobile phone number 11 ASCII characters such as 15810437433 MODE There are three modes for A GPRS1090 Always online Offline when idle Power down when idle E Always online It will connect to the preconfigured server when power on the module And it will be kept online all the time so the data can be transmitted at any time BR Offline when idle It will connect to the preconfigured server when power on the module The module will disconnect and turns to the sleeping mode if there isn t any data in a period of time There are three methods to enable re establish connection between the module and the server 1 Send data to the serial port of the module the module will connect to the server and then send the out 2 Telephone wake up call the SIM card number hang up after it rings for two times the module will re establish a connection with the server 3 SMS wake up set one of the SMS certification users to the SIM card number in the Configuration Tool The format of the number is 861 for China s SIM card it is 86 Send the SMS 888888 Wakeup It will return OK which means the module has re connected to the serve BR Power down when idle after the module disconnecting the connection with the server the module will cut off the power of GPRS module and make the system into power down status to achieve low power consumption There is only one method to wake
3. Work mode Always online Stop Bit 1 S Module Type Client Be None Transfer mode Agreement transfer Parity Bit Data Certer Number 1 DNS1 211 136 17 107 DIN Q 06 0 20 r 7 Main Data Center IP 221 218 157 69 Exit configuration Main Data Center Domain Main Data Center Port No 5000 Get information Main Data Center link Mode TCP Backup Data Center IP Save setting Backup Data Center Domain www art control com Backup Data Center Port No 4000 Reset DTU module Backup Data Center link Mode UDP 1 e The number of reconnection 3 The number of reconnection interval 10 The two batches of target is heavy co 1 Export configuration J D L COM Baud Rate 115200 a e 8 Import configuration COM Data Bit length COM Stop Bit length 1 Serial Check Type None Heartbeat Package Intervals 100 Language English v Heartbeat Package Timeoutis 300 COM Baud Rate R A Z A 20 CZ Beijing ART Technology Development Co Ltd 7 Serial port settings A GPRS1090 provides a serial port to transfer the data serial port configuration is shown as the following 8 Heart rate settings Heartbeat Package Interval it will send a heartbeat in a certain time the default value is 30s and we can change it in the program Heartbeat Package Timeout the module will re connect in timeout if there is no heartbeat The default value is 120s we can change it in the program GPRS Configuration Tool U6 81 19
4. 0 43 1 0 Wuel COMCOME 30 ec io e Delete Terminal System information Terminal information Terminal Property Information 2010 8 217 7 43 Close Server Monitor port 5000 _ cearrecoa 2010 8 217 7 50 Start successful 2010 8 217 7 50 Server Listen Port 5000 the maximum number of allowed connections 100 2010 8 2 17 8 52 Module DTU109X 0 has client connection IP 117 136 0 41 L saverecod 2010 8 2 17 15 23 Start TCP Port mapping success Port 6000 2010 8 2 17 16 59 Module DTU109X 0 has client connection IP 117 136 0 43 2010 8 218 6 10 StartVitual COM mapping success TOM B7 Terminal Amounts P Sever Settings G 1 On line number 1 x Data distribution rules virtual serial port forwarding Open the COMI to connect with A GPRS1090 COMI can send data to the ARTServer and then ARTServer can transmit data to the virtual serial port COM6 We can detect the uplink data that is sent by COM1 of A GPRS1090 through terminal information of the server program the virtual serial port COM6 sends the downlink data Shown as the following 28 C Beijing ART Technology Development Co Ltd 5 2 Transparent Transmission 5 2 1 Configuration Settings 1 First set the transferring mode to the transparent transmission 2 Others are the same as protocol transmission Note in this mode data packets do not have the header 5 2 2 Server Configuration Use Network D
5. 17 8 52 117 136 0 41 a 0 30 120 Delete Terminal lt System information Terminal information Terminal Property Information 2010 8 217 7 43 Close Server Monitor port 5000 Clear Record 2010 8 217 7 50 Start successful g 2010 8 217 7 50 Server Listen Port 5000 the maximum number of allowed connections 100 Sever Settings 2010 8 2 17 8 52 Module DTU109X 0 has client connection P 117 136 0 41 Terminal Amounts 1 On line number 1 x Data distribution rules physical serial port forwarding Open the serial port COM3 to connect A GPRS1090 device connect the physical serial port COM1 with another unoccupied serial port COM2 COM3 can send data to ARTServer and then data is transmitted from the server to the COMI We can detect the uplink data that is sent by COM3 of A GPRS1090 through terminal information of the server program COM1 can connect with other devices to send the downlink data 2 TCP serial port forwarding test Click the left Mapping management button it will pop up dialog box Mapping Manage Terminal name DTUIORX 0 ei Mapping to ES SC D lt Mapping 25 U Beijing ART Technologv Development Co Ltd Map the DTU 1090 0 which is new connection device to the TCP serial port we can change serial number the default number is 5000 Click the mapping button show as the following Mapping Manage Ma
6. A GPRS1090 User s Manual CO Beijing ART Technology Development Co Ltd 0 Beijing ART Technologv Development Co Ltd Contents Contents sive cians i ie sa dE EES Eege dia dee 2 Chapter 1 Introductions minisun ee b ses e e l ae 3 MV OVER VIG W sr e e e e 3 LEE e A A EE AE EAS 3 1 3 Hardware Introduction niisiis E a E E a E A EAEE dd bba 4 1 3 1 Serial Communi Catt OMe sses sieunna aeaa EE EEN gege 4 l 3 2 Indicator EiS EE 5 LA CHECK List ii si iruis iibiiitiari aeaeaei aaaea A EAS E tothe be AS AEE E gen BA a a tu g ada ati 5 i 3 Installitieti E 6 Chapter 2 Parameter Confisuratioti 2 si Pie e B g ei 7 2 1 Lo al Seral Port Cons uration ett gege EES EES EENEG ees EA 7 2 1 1 GPRS Config exe Configuration Program 8 2 1 2 AT Parameter Configuration Protocol en nneenennnnan nanna anna inana ata nanna iaasa 8 2 2 Long distance Configuratio j sescisesese crave ia ei bt tie EA g G EEA ip e B ba Ea EN G rt bet 11 2 3 Messase EE EE 12 Chapter 3 Function Settings Description c ciicc ccccsscestestesccsecescavtoctcocnossbccasvesunesenveesonsseavtosausudveaduentdesuevutevseussuvesveostessvensdsentes 13 ENEE e 16 AV OV RVI eege ie e a e Saude a g e aas 16 A 2 Usape Instructions seins iio EES 16 Chapter 5 Application Introduction 0 eee eccesecseeeeceeeeseesecseeeeceaecseseecesecsesseseeeesecsesseseeecascaeseeeeaecaesaeseeeeaseaeeeseeeeaaees 20 5 1 Protocol Transmissie e e B ep E G SEa S 20 5 1 1 eent ere 20 9 1 2 ARFServer server Pro
7. Local COM Configur B Goal Setting Data Certer Number 1 COM1 sl 115 2 kbps DNS1 211 136 17 107 DNS2 202 106 0 20 Main Data Center IP 221 218 157 69 i 8 Main Data Center Domain Main Data Center Port No 5000 i 1 Main Data Center link Mode TCP Backup Data Center IP Backup Data Center Domain Wa art control com Backup Data Center Port No 4000 Backup Data Center link Mode UDP The number of reconnection a The number of reconnection interv 10 The two batches of target is heavy 1 E Transmission control Get information COM Baud Rate 115200 COM Data Bit length Save setting COM Stop Bit length Serial Check Type Reset DTU module Heartbeat Package Interval s 30 Heartbeat Package Timeoutis 120 Restore factory Setting Heartbeat Package Data Set 254 Frame Interval ms 100 Packet Maximum Length 512 Idle offline time 60 D Network Parameters APN APN User Name APN Password Language English v SMS Center No i SMS Center No del R fe H A Exit configuration Export configuration Import configuration 5 1 2 ARTServer Server Program Start all programs ART Data Acquisition Measurement Suite A GPRS 1090 ARTServer Service procedure 1 Click the Service Settings button to set the main server port number the port number should be the same as the Main Data Center Port No show as the following 21 U Beijing ART Technologv Development Co Ltd Service setting Service setting Monitor por
8. PRS automatically and then when users open the computer ARTServer will be activated automatically Add terminal Wireless module through name and IMEI which is the unique identifier of module can be added in the server program of ARTServer show as figure Add Terminal COM IME 123456789666666 Name Art Heartbeat Interval 30 30 65534 Sec Heartbeat Time 120 30 65534 Sec Instruction 1 IMEI must be 15 bits 17 C Beijing ART Technology Development Co Ltd 2 Terminal existence If you do not choose the Terminal existence it will be an invalid terminal ARTServer does not accept the connection request from terminal 3 Heartbeat interval refers to the time of sending a terminal heart to ARTServer Heartbeat overtime means the terminal does not receive the heartbeat packets from ARTSever for seconds and then it will think the module has been dropped After has dropped the terminal it will determine next connection according to their own try spacing parameter Heartbeat parameters ensure the terminal on line the value can be set by users Delete terminal Click the list box to delete the terminal select the menu Terminal Management delete Terminal or click the toolbar terminal delete button pop up dialog box to confirm the deletion Clicks Yes while the terminal deleted Mapping management ARTServer supports four mapping methods terminal to terminal terminal to loca
9. RT Technologv Development Co Ltd 801 0 0 7 icetcp TCP UDP 4F 4B 0D 0A Setting View Options Client Server M Hex RX 4 TX 12 m Transmit Options Port 6000 SSS Hex Auto 0 ms AutoAck Close Connect 00 00 00 00 00 06 00 02 00 00 00 08 Connected 127 0 0 1 6000 2649 848228ms Remote Host 127 0 0 1 i Status 1 We can detect the uplink data that is sent by COM3 of A GPRS1090 through terminal information of the server program the serial port 5000 of TCP sends the downlink data Shown as the following 3 Virtual serial port forwarding test Click the left Mapping management button then it will pop up dialog box Mapping Manage Terminal name DTUIOS lt 0 Mapping to Virtual COM v lt Mapping TCP Port Map the DTU1090 0 which is new connection device to the virtual serial port serial port is COM6 Click the mapping button show as the following 27 CZ Beijing ART Technology Development Co Ltd Mapping Manage Virtual COMC Terminal name All terminals Mapping to Virtual COM lt Mapping configure TCP Pott Main server program will add virtual serial port function B ARTServer Control Terminal Manage Settings Test Record Manage Language Help COM Number IMEI MES State Ken Time Terminals IP addr Send Receive Mapping Record K sse 149241003604875 DTU109x 0 Onine 2010 8 2 17 16 59 117 136
10. Sami eet 21 5 2 Transparent Transmission eege N E ENEE EENEG der 29 5221 Conte uration SEMA 8 vy css sev e ii piia E a ar A E p Ea ENE SEVAN ae S AEREE T N E E EES RN 29 5 2 2 Serv r COME PULAU OM sinire a EA a E NE OEE ETES 29 ENER KEE CN 31 C Beijing ART Technology Development Co Ltd Chapter 1 Introduction 1 1 Overview GPRS is short for General Packet Radio Service it has superiority owe to its high speed transmit and always online and it is very fit for the situation that there are much data to transmit but the time is not continuous GPRS1090 data acquisition is an extension of PC based data acquisition to measurement applications where cables are inconvenient or uneconomical GPRS1090 data acquisition DAQ devices combine TCP IP communication the flexibility of driver software for remote monitoring physical mechanical and acoustical signals GPRS 1090 makes it easy to incorporate wireless into new or existing PC based measurement or control systems Operating System Support The operational under most popular operating systems such as windowsxp 2000 2003 Vista etc however ART device drivers provide easier installation configuration and better performance for windowsXP windows2000 2003 Vista Please refer to the respective operating system s manual for how to install and configure the standard driver Wide Applications A GPRS1090 module has a wide range of applications following are some typical applications 1 P
11. T Technology Development Co Ltd 2 RS485 If RS485 uses 9D interface shown as the following Otherwise we also can lead out RS485 interface through 3P terminal the side of schematic diagram AcT C ONET 3 2 l PWR PWR The definition of 3P terminal 1 3 2 Indicator Light NET Network status indicator on for normal PWR Power indicator on for normal ACT GPRS status and communication indicator 1 4 Check List Unpack the A GPRS1090 series package you should find the following items 1 A GPRS1090 data acquisition module 2 Device driver diskettes a Driver b User s manual this manual 3 One serial port cable 0 Beijing ART Technologv Development Co Ltd 4 One 9V Power Supply 1 5 Installation Guide Methods about how to install A GPRS1090 in different operating svstems are the same our companv provides a CD ROM that contains the installation program Setup exe and users double click the installation program then through the prompting of the interface to complete the installation 2 Beijing ART Technology Development Co Ltd Chapter 2 Parameter Configuration We have three ways to configure parameters of A GPRS1090 these are local COM port configuration long distance configuration and message configuration 2 1 Local Serial Port Configuration There two configuration methods GPRS Config exe configuration program or AT comm
12. and There are two ways can enter to the local configuration mode show as follows 1 When DTU power on when give the power to DTU it will check whether there is space in the serial port if there is space that the user requested access to the configuration mode Therefore we only need to send space to serial port continuously before give the power to DTU baud rate 115200 8 bit data bit 1 stop bit noparity and then give the power to DTU you can enter the local serial port configuration mode Note If it receives character e when give the power to DTU it will rest DTU if it receives character a we can do AT mandate for SIM300 2 When DTU normal working when DTU is in a normal communication status we can send characters in table 2 1 to DTU through serial port to make DTU exit present work mode and then enter the configuration mode Table2 1 Pre idle time Character Idle interval time Least 100ms is set inn Least 100ms 0 Beijing ART Technologv Development Co Ltd 2 1 1 GPRS Config exe Configuration Program The methord of A GPRS1090 enters to the configuration mode first do not give the power to module 1 Connect the COM port with the module 2 Click the enter configuration status button and then give power to A GPRS 1090 quickly Show as the following GPRS Configuration Tool U6 01 19 Local COM Configur IS DN Ev Baud Rate 115 2kbps ze Device ID Devi
13. ce name Data Bit 8 SIM card number Work mode Stop Bit 1 Module Type taxa Transfer mode Parity Bit Data Certer Number DNS1 DNS2 Main Data Center IP Exit configuration Main Data Center Domain Main Data Center Port No Main Data Center link Mode Backup Data Center IP Backup Data Center Domain Backup Data Center Port No Backup Data Center link Mode The number of reconnection The number of reconnection interval The two batches of target is heavy connect interrupt interval E1 nission COM Baud Rate COM Data Bit length COM Stop Bit length Serial Check Type i E Heartbeat Package Interwalis Language English v Heartbeat Package Timeout s COM Stop Bit length fy L fi A Enter configuration Export configuration Import configuration 3 Click the get information button then we can read the information of module or we can wait for seconds because it can get information automatically 4 In the left of user interface there is a local COM port configuration tool we can change the information in it when it has been changed we can save new information by clicking the save configuration button 2 1 2 AT Parameter Configuration Protocol After DTU into the configuration mode accordingly we can send command frames with configuration message by command frames we can read or write parameters Command frames all use ASCII characters This not only gives the user convenient to use hyper terminal for paramet
14. ebugging Assistant to create a server open a port the port number is the same as the port number of module configuration program Show as the following Xc 1 0 0 7 icetcp Setting View Options Hien Hex AX 0 TX 0 Remote Host 127 0 0 1 Transmit Options Port V Hex Auto 0 ms J AutoAck Sena Stop Close Connect 00 00 00 00 00 06 00 02 00 00 00 08 EE 17204475 222592ms Status 2 29 0 Beijing ART Technologv Development Co Ltd Give the power to A GPRS1090 waiting until the module connects with the server Show as the following 6 1 0 0 7 icetcp Help mp UDP SS SS 404 00 1E 31 34 39 32 34 31 30 30 33 36 30 34 38 37 35 01 2C 00 64 0A OF A7 OE 00 00 00 00 Setting View Options Client M Hex RX 30 TX 0 I Clear Remote Host 127 0 0 1 Transmit Options ao eas M Hex T Auto O ms T AutoAck Stop Close Connect 00 00 00 00 00 06 00 02 00 00 00 08 Comnected 117 136 0 9 5557 17204475 222592ms Status 3 Data distribution rule transparent transmission Open COMI to connect with A GPRS1090 COMI can send uplink data to the server the server sends the downlink data to the serial port COMI 30 C Beijing ART Technology Development Co Ltd Chapter 6 Fault Diagnosis The following are a series of common faults of GPRS 1090 possible causes and solutions If the problem persists users can directly connect with the ART in order to get technical support 1 The module can not work well possib
15. er If it suddenly disconnected in operating mode the target server will switch back to the main central server TRYCNT TRYTIM TRYSPAC The number of target re connection used to control the number of the same goal connection of the connection with batch 0 stands for regardless of batch The interval of target connection is used to control the time between two connections the smallest time is 10s and the longest time is 65 5536s The interruption interval of target connection is used to control the time of two groups connections the smallest is 1 minute and the longest is 65 534 minutes SERBAUD Serial baud rates Table3 13 Supported baud rates 300 600 1200 2400 4800 9600 19200 38400 57600 115200 SERDAT SERSTP Serial data bit stop bit length SERCHK Check type of serial Table3 15 relationship between values and checking types Set value BEATTIM Users can set heartbeat packet interval time the range is 30 65534 unit seconds 14 C Beijing ART Technology Development Co Ltd BEATDATA User can manually set the heartbeat data such as 0x3F using the AT command configuration format AT BEATDAT 3F SERS MTU Frame interval of time and the maximum length of data packets IDLETIM Idle time of downline APN USRNAM PWD APN name user name and password LCOPORT Local port number DTUPWD Login Password DBGINF This parameter controls
16. er configuration in absence of configuration tool but also allows users to write the DTU configuration program in their own device easily Command frame structures are shown in Table2 1 4 1 There are two types of command write commands and read commands Write commands are used to configuration parameters read commands are used to query the current configuration The difference between them is that read commands are not with configuration parameters and characters after the command are different Write 2 Beijing ART Technology Development Co Ltd wow commands said the assignment Read command said the question Command codes are different because the configuration objects are different but these codes must comply with requirements of regulations show as Table 2 1 4 2 If use other command codes DTU will return ERR CMD for another way if write command with parameter configuration is not illegality for example the baud rate has surpassed the scope of requirement then DTU will refuse to receive this parameter and return ERR DATA Note 1 The data in command frame is all ASCII characters all input characters are not case sensitive 2 Command codes according to Table 2 1 4 2 3 Write command frame length according to Table 2 1 4 2 Table2 1 4 1 Write Command AT command code parameter Right OK r n it C d aes eek ERR CMDirin Response mistake Parameter l ERR DATA mistake Read Com
17. ion Remote Configure Ethernet Remote Configure Send frame l Commane ATSCFGLIST Read only Parameter l Explain Read all the commands and command values Read only S 123456789666666 REAP At Dt Send Clear Receive frame Cancel 11 2 Beijing ART Technology Development Co Ltd 2 3 Message Configuration SMS configuration is a mobile phone enter commands to configure but please note Note One message only can send one command format is 6 passwords command without the prefix AT All characters are Western Not only the telephone number is the same as certification number but also the passwords have been passed then SMS configuration can work SMS wake up command WAKEUP SMS Configuration Support Telephone wake up telephone call s time must over two rings and was hung up after the wake up 12 C Beijing ART Technology Development Co Ltd Chapter 3 Function Settings Description Export Configuration Save the modified configuration items Import Configuration Load the configuration items previously saved Reset DTU Module Software reset actions will be executed Restore Factory Settings Restore module to factory settings in case of configuration confusion SWVER Software version DTUNAM DTU device name be used to distinguished different devices when multiple modules are being used DTUNAM limited to 15 characters
18. ion interrupt interval COM Baud Rate RW SERBAUD 6 300 115200 COM Data Bit length RW SERDAT 1 5 8 COM Stop Bit length RW SERSTP 1 1 2 Serial Check Type RW SERCHK 4 Transmission Heartbeat Packet Interval RW_ BEATTIM 5 30 65534s Control Heartbeat Packet Timeout BW BEATOUT 5 30 65534s Heartbeat packet data setting RW BEATDATA 2 One byte of Hex such as FE Frame interval RW SERS 5 Packet Maximum Length RW MTU 4 1 1024 byte Idle offline time RW IDLETIM 5 30 65534ms APN RW APN 20 Default empty APN User Name RW USRNAM 20 Default empty APN Password RW PWD 20 Default empty SMS Center No RW SMSNO 14 Default empty Network Local Port No RW LCOPORT 1 Default 2020 Parameters f SMS Certification User 1 RW USERNOI 14 SMS Certification User 2 RW USERNO2 14 SMS Certification User 3 RW USERNO3 14 Module Password RW DTUPWD 6 ON putout Control SE Debugging information output RW DBGINF 3 ON putout Command 10 O Beijing ART Technology Development Co Ltd 2 2 Long distance Configuration Remote configuration using ARTServer service program show as figure B ARTServer Control Terminal Manage Settings BESS Record Manage Language Help COM Numberllk d ate Connection Time Terminals IP addr Send Receive Mapping ESSEE send Data pe p jj G f00 Add Terminal Delete Terminal Terminal Property E Sever Settings Mapping Manage System information Terminal information Informat
19. l physical serial port terminal to the local virtual serial port terminal to the local TCP port 1 terminal to terminal mapping two terminals exchange the data by ARTServer 2 Terminal to the local physical serial mapping ARTServer opens a specified and actual serial port and then transmit data between terminal and the serial 3 Terminal to the local virtual serial port mapping ARTServer creates a virtual serial port and then transmit data between virtual serial port and terminal 4 Terminal to the local TCP port mapping ARTServer opens a local server port and then transmit data between terminal and the TCP port Show as figure Mapping Manage Terminal name Mapping to lt Mapping TCP Port Instruction 1 terminal own should not map when map TCP ports TCP port numbers are different 2 Make sure that no program is opening the virtual serial port when we want to delete it 3 If you want to delete the mapping please click the Mapping to remove the one which you want to delete and then click the delete mapping option 18 2 Beijing ART Technology Development Co Ltd Information ARTServer has system information and terminal information 1 System information shows the total number of terminals and the number of online terminals 2 Terminal information shows terminal connection status heart rate receive and send data System information Terminal information
20. le reasons are in the following a The antenna does not contact well b The SIM card does not contact well c The SIM card does not have the money d The network is not connection or the speed is too slowly e Public Network IP has changed or oray has disconnected 2 when working a period of time the module short terms automatically the possible reasons are in the following a The Network is not connecting well b If using Public Network it maybe the Public Network has changed c The SIM card does not have the money d The module receives too many data in one time 31
21. mand AT Command Code r n Read Response Command Code Parameter r n Table2 1 4 2 Module tvpe R DTUTYPE 10 Such as ART1090 Device ID R DTUID 15 unique ID can not be changed Device software version R SWVER 5 Such as V1 00 Local COM Device name RW DTUNAM 15 Such as ARTDTUOI Configuration SIM card number RW PHON 11 Such as 15810437433 Work mode RW MODE 1 ER winding2 idlepower down Modein RW DTUMODE i O clientl server 2 CSD client 3 CSD server Transport Mode RW DATMODE 1 Goal Setting Data Center number RW SVRCNT 1 1 2 DNSI RW DNSIIP 15 Such as 202 106 0 20 DNS2 RW DNS2IP 15 Such as 211 136 17 107 Main Data Center IP RW SVRIP 15 Such as221 218 157 55 Main Data Center Domain RW SVRNAM 40 Such as www sohu com Main Data Center Port No RW SVRPORT 5 Such as 80 2 Beijing ART Technology Development Co Ltd 0 TCP connection Main Data Center Link Mode RW SVRMODE 1 1 UDP connection Backup Data Center IP RW SVRIIP 15 Such as 192 168 0 1 Backup Data Center Domain RW SVRINAM 40 Such as www 163 com Backup Data Center Port No RW SVRIPORT 5 Such as 80 Backup Data Center Link 0 TCP connection RW SVRIMODE 1 Mode 1 UDP connection The number of reconnection RW TRYCNT 2 1 99 The number of reconnection l RW TRXTIM 5 10 65534s interval Two batches of target ee A RW TRYSPAC 5 reconnect
22. ower Down Automatically Meter System 2 Environment Monitoring System 3 Urban Street Lamps Lighting System 4 Industrial Automation Control System 1 2 Features BR Support Dual band GSM GPRS RH Transparent Data transmission build in TCP IP protocol stack provide RS 232 485 interface provide transparent transmission channel BR Support data center dynamic domain name or IP address access BR Support three working mode on line forever idle offline and idle power off HR Support the function that can be woken up by text message and mobile telephone BR Support the automatic re connection function HR Support local and remote graphical interface for configuration and the maintenance H Reliable design of multiple hardware and software and build in the watchdog BR Support dial up Networking through the serial port BR Supply single voltage from 7V 26V Recommended 9V 12V E Maximum operating current 300mA and the sleep time lt 10mA 3 2 Beijing ART Technology Development Co Ltd E Operating Temperature 20 C 70 C HR Operating Humidity 90 1 3 Hardware Introduction A GPRS1090 diagram is as follow The side of schematic diagram AcT O exer pwr PWR 1 3 1 Serial Communication 1 RS232 Interface NC If it is used with DAM3210 we need to use cross serial cable if it is connected with PC to configure parameters we should use direct attached serial cable Z Beijing AR
23. pp CL U DS 0 Z TCP Port6000 Terminal name Al terminals v Mappingto TCP Port v lt Mapping UM contigure TCP Pott Then master service will add the TCP serial port forwarding function B ARTServer Control Terminal Manage Settings Test Record Manage Language Help COM NumberllMEI Name State Connection Time Terminals IP addr Send Receive Mapping Record Heartbeat Interval 149241003604875 DTU1OSX 0 Online 2010 8 2 17 16 59 117 136 0 43 1 D CP Port6000 30 p System information Terminal information Information em 2010 8 217 7 43 Close Server Monitor port 5000 Clear Record 2010 8 2 17 7 50 Start successful 2010 8 217 7 50 Server Listen Port 5000 the maximum number of allowed connections 100 2010 8 2 17 8 52 Module DTU109X 0 has client connection P 117 136 0 41 SaveRecod 2010 8 2 17 15 23 Stat TCP Por mapping success Fort 6000 2010 8 2 17 16 59 Module DTU109X 0 has client connection IP 117 136 0 43 Terminal Amounts 1 On line number 1 xk Data distribution rules TCP serial port forwarding Open the COMI to connect with the serial port of A GPRS1090 then COM1 can send the data to the ARTServer then ARTServer can transmit data to the serial port 5000 of TCP Open Network Debugging Assistant we can use it as client to connect with serial port 5000 of TCP in this way it can realize data transmission Show as the following 26 U Beijing A
24. t Most link 10771000 C Automatically starts DTU when Windows starts 2 Click the Start Service button to create a master server Show as the following B ARTServer Control Terminal Manage Settings Test Record Manage Language Help COM Number lMEI Name State Connection Time Terminals IP addr Stop Server Delete Terminal Terminal Property lt Send Receive Mapping L System information Terminal information Information DHE 31 22 Start successful Clear Record 2010 8 2 15 31 22 Server Listen Port 8000 the maximum number of allowed connections 100 Mapping Manage Save Record Ko pen 22 CZ Beijing ART Technology Development Co Ltd 3 Power on A GPRS 1090 module insert the SIM card which has GPRS services to the module Then waiting for the module to connect the server After seconds the module connects the server successfully show as the following B ARTServer Control Terminal Manage Settings Test Record Manage Language Help COM Number IMEI aL Rene State Connection ime j Terminals IP addr Send Receive Mapping Record Heartbeat Interval O O ha System information Terminal information x Information Delete Terminal p 2010 8 216 6 37 Start successful Clear Record amo 8 216 6 37 Saver Listen Port 5000 Terminal Property A Sever Settings Terminal Amounts G Mapping Manage 1 On line n
25. umber 1 4 The server program realizes data transmission and it can achieve physical serial port forwarding TCP port forwarding and virtual serial port forwarding 1 Physical serial port forwarding test Click the left Mapping management button it will pop up dialog box Mapping Manage Terminal name DTUIOS 0 Mapping to Physics COM v lapping COM1 TCP Patt 23 U Beijing ART Technologv Development Co Ltd Map the DTU 1090 0 which is new connection device to the physical serial port serial number is COM1 Click the serial configuration dialog box show as the following configure serial The mapping button is valid after configured the serial port Serial Port Configuration ix Baud rate b Data Bit Check Type Stop Bit Click the Mapping button show as the following Mapping Manage Mappi DTU109x 0 t Physics COM Terminal name All terminals Mapping to TCP Port lt Mapping COMI COM configure TCP Pott 5000 24 C Beijing ART Technology Development Co Ltd Then master service will add the physical serial port forwarding function B ARTServer DAR Control Terminal Manage Settings Test Record Manage Language Help ja COM NumbertiMEL Name Te 1 Ee Tre if TAT IP addi f iced Receive Nenad Record Heartbeat Interval Heartbeat tir 143241003604875 DTUIOSK 0 Ondine 201082
26. up the module send data to the serial port of the module the module will connect to the server after the data is sent successfully 13 U Beijing ART Technologv Development Co Ltd DTUMODE This parameter is used to set the module s functionalitv mode CLIENT or SERVER For CLIENT mode the module connects the data center server as a client For SERVER mode the module wait for the connection from the client as a server When use the point to point function configure one module CLIENT and the other SERVER SVRIP SVRNAM SVRPORT CNTMODE the parameters of the main center server A target server configuration includes IP address and port number if the server does not have a fixed IP address vou can use the domain name When the server IP address is validity the domain name will be ignored In communication network it has TCP and UDP communication SVRIIPI SVRINAM1 SVRIPORT1 CNTMODEL the parameters of the secondary center server A target server configuration includes IP address and port number if the server does not have a fixed IP address you can use the domain name When the server s IP address validity the domain name will be ignored In the several attempts to connect the main central server fails the module will automatically switch to connect alternate central server When using the standby server if it suddenly disconnected during the remote configuration the module will re connect standby serv
27. whether the data input is echo and whether there are debug information outputs 15 0 Beijing ART Technologv Development Co Ltd Chapter 4 Server program 4 1 Overview ARTServer is a wireless communication server application which is running on Windows operating svstems A GPRS1090 module is supplied by our company At can transmits communication between module and server client connections management client mapping data transmission and other functions can be realized by the server 4 2 Usage Instructions Application framework Show as figure B ARTServer Control Terminal Manage Settings Test Record Manage Language Help COM Number IMEI Name State Connection T Terminals IP ad Send Receive Mapping Record Heartbeat Interval Heartbeat 123456789666666 Art Off line 0 0 30 120 Add Terminal Delete Terminal Terminal Property Sever Settings Mapping Manage System information Terminal information l Information 16 C Beijing ART Technology Development Co Ltd Server Settings Show as figure Service setting Service setting Monitor port Em Most link 100 0 1000 C Automatically starts DTU when Windows starts Instruction 1 Defaulting monitor port is 8000 the server program allows only one monitor port to the outside world allowing 1000 clients to establish connection at the same time 2 Users can also select When Windows starts activated A G

Download Pdf Manuals

image

Related Search

Related Contents

Socket Mobile SoMo 650-E  Samsung SGH-E820T Felhasználói kézikönyv    Lenovo A7-50 16GB Black  Class 1 USB Adapter - Hawking Technology  メーカーカタログを見る(PDF:3.4MB)  メーカーデータ  Home Decorators Collection 1140300210 Instructions / Assembly  Operating instructions RS-P42 Printer, Bedienungsanleitung  Dataram 4GB DDR3-1600  

Copyright © All rights reserved.
Failed to retrieve file